Professional Documents
Culture Documents
Murali Krishna A.
ABSTRACT: Retaining structures are designed to withstand lateral pressures due to backfill, surcharge load from adjacent structures
and traffic and earthquake loads. The cost of these structures is directly proportional to the earth pressures they are subjected to.
Several techniques have been tried in the literature to minimize the earth pressure exerted on retaining walls. Among them, use of
geofoam as a compressible inclusion placed at the wall-backfill interface, is found to be a simple and effective solution, based on
preliminary studies. However, behaviour of EPS geofoam and its influence on the earth pressure reduction under seismic loading
conditions are not well understood, and need to be investigated further. In the present study, small scale physical model tests were
performed on an instrumented retaining wall subjected to 1-D shaking, to evaluate earth pressures on the wall and to assess
effectiveness of EPS geofoam to reduce seismic earth pressures. Firstly, static surcharge loading was applied in order to evaluate
magnitude and distribution of earth pressure. Further, under maintained surcharge, a seismic load in the form of a stepped sinusoidal
wave from 0 to 0.7 g was applied in increments of 0.045 g, each increment being applied for 5 seconds at 3 Hz frequency. The
experimental results indicate that the earth pressures under the influence of a seismic load show an increase of the order of 23%.
Moreover, by using the geofoam as a seismic buffer, it was observed that the total seismic force on the retaining wall reduced by
about 23% with a corresponding reduction in maximum lateral thrust by 27%.
RSUM : Les structures de soutnement sont conues pour rsister des pressions latrales dues au remblai, la surcharge de
structures adjacentes, au traffic et aux charges sismiques. Plusieurs tudes ont t ralises dans la littrature minimiser la pression des
terres sur des murs de soutnement. Dans la prsente tude, des exprimentations ont t excutes sur un mur de soutnement
instrument pour valuer la pression des terres et l'efficacit du Polystyrne, sous sollicitation sismique gnre par une table vibrante
1D. Premirement, une surcharge statique tait applique afin d'valuer la distribution de la pression des terres. Puis, sous la surcharge
maintenue, une charge sismique sous forme de vague sinusodale de 0 0,7 g tait applique par paliers de 0,045 g, chaque
augmentation tant applique pendant 5 secondes 3 hertz de frquence. Les rsultats exprimentaux indiquent que les pressions des
terres, sous l'influence d'une charge sismique montrent une augmentation de l'ordre de 23%. De plus, avec le polystyrne comme
amortisseur sismique, on a observ que la force sismique totale sur le mur de soutnement diminue d'environ 23% avec une rduction
de la pousse latrale maximum de 27%.
INTRODUCTION
903
REVIEW OF LITERATURE
Proceedings of the 18th International Conference on Soil Mechanics and Geotechnical Engineering, Paris 2013
EXPERIMENTAL PROGRAM
904
905
Proceedings of the 18th International Conference on Soil Mechanics and Geotechnical Engineering, Paris 2013
CONCLUSIONS
906
REFERENCES