Professional Documents
Culture Documents
TECServicesperformedadhesiontestingonStormGreeterattherequestofSouthern
Company,Inc.priortosubmittingittoEPRI.TheTECreportsareincludedonthenexttwo
pages.
ASTMD454102InthefirstroundoftestingatEPRI,StormGreetersresultsweresimilarto
whatTECfoundfortheD4541tests.InthesecondroundoftestsatEPRI,usinga2to3mil
anchorpatternonthetestcoupons,StormGreeterreached500psiadhesion.
PerNealMurray,ProjectManageratEPRI,thefailuresduringASTMD454102wereasfollows:
60%adhesionfailuretheadhesiveholdingthetestdollyfailed.Thishasbeena
commonoccurrenceatbothEPRIandTEC.Commonadhesivesusedforthistesthavea
difficulttimeadheringtotheStormGreetersurface.
30%cohesionfailureStormGreeterformedadoublelayeratthepointoftestingand
separated,leavingalayeronthesubstrate.
10%coatingfailureStormGreeterfailedbetween450and500psi.
Mr.MurraysuggeststhatStormGreeterbeappliedovera4to5milanchorpatterntoreach
higherpsiadhesionstrengths.
ASTMD667701TEChasperformedtheXcutPullofftests.StormGreeterscored10on
everytest.
Ovante,LLC1479MillstreamRoadTallahassee,FL323153343639558www.ovantellc.com
ThemethodsandequipmentdiscussedarepatentpendingandthepropertyofOvante,LLC.