Safety-related controls
SIRIUS Safety Integrated
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
Preliminary comment
Safety Functional Examples are functional and tested automation circuits based on
standard A&D products. They can be used to simply, quickly and cost-effectively
implement applications in safety technology. Each of the Safety Functional
Examples covers a sub-task of a typical customer application involving safety
technology that is frequently encountered.
Function ........................................................................................ 2
1.1
1.2
Advantages/customer benefits....................................................... 3
Components required.................................................................. 4
3.1
3.2
Evaluation/feedback ....................................................................................... 7
Note
The Safety Functional Examples are not binding and do not claim to be
complete regarding the circuits shown, equipping and any eventuality. The
Safety Functional Examples do not represent customer-specific solutions.
They are only intended to provide support for typical applications. You are
responsible in ensuring that the described products are correctly used. These
Safety Functional Examples do not relieve you of the responsibility in safely
and professionally using, installing, operating and servicing equipment. When
using these Safety Functional Examples, you recognize that Siemens cannot
be made liable for any damage/claims beyond the liability clause described
above. We reserve the right to make changes to these Safety Functional
Examples at any time without prior notice. If there are any deviations between
the recommendations provided in these Safety Functional Examples and other
Siemens publications - e.g. Catalogs - then the contents of the other
documents have priority.
Page 1/7
CD-FE-I-023-V01-EN
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
Function
1.1
Actuator
Page 2/7
CD-FE-I-023-V01-EN
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
Cascading input
(1)
Relay output,
instantaneous
(13 / 14)
EMERGENCY
STOP
(Y42)
Electronic output,
instantaneous
contactor K1
(24)
Protective door
(Y42)
Relay output,
instantaneous
(33 / 34)
Electronic output,
instantaneous
contactor K2
(44)
Key-operated
switch "service
mode"
(Y72 / Y82)
1.2
Advantages/customer benefits
Pure hardware engineering without having to configure/program
software
Little wiring is required and it is simple
Space-saving design using our compact safety relay
Can be simply expanded using expansion devices
Page 3/7
CD-FE-I-023-V01-EN
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
Components required
Hardware components
Type
3SE2 243-0XX40
Component
SIRIUS position switch
Actuator for position switch
E-Stop
safety relay
Contactors K1 / K2
3SX3 228
3SB3 801-0DG3
Qty.
Manufacturer
1
1
3SB3 802-0AA3
3SB3 420-OB
1
2
Siemens AG
3SB3 000-0AA11
1
3SB3000-4LD01
3TK2845-1BB40
3RT1015-1BB42
1
1
2
Note
The functionality was tested using the specified hardware components. Products that are similar
but deviate from the list above can be used (e.g. a different 3TK28 safety relay). However, in
this case, please carefully note that it may be necessary to make modifications as to how the
hardware components are connected-up (e.g. another connection assignment).
Page 4/7
CD-FE-I-023-V01-EN
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
3.1
Protective
door
E-Stop
Start
mode
L1 L2 L3
L1 L2 L3
K2
K1
3.2
Protective
door
E-Stop
3TK2845-1BB40
Service
mode
13
14
24
Y72 Y82 A2
33
34
44
Y34 Y64 32
Start
K1
M1
K1
M
Page 5/7
K2
K1
K2
K2
M2
CD-FE-I-023-V01-EN
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
Contact partners
Technical Assistance for low-voltage switchgear
In person from Mon. - Fri. 8.00 to 17.00 (CET)
Telephone: +49 (911)-895-5900
E-Mail: technical-assistance@siemens.com
Internet: http://www.siemens.de/lowvoltage
By fax, 24 hours a day
Fax: +49 (911)-895-5907
Page 6/7
CD-FE-I-023-V01-EN
E-Stop with monitored start, protective door monitoring with automatic start and
service mode, Category 2 according to EN 954-1
Evaluation/feedback
Technical Assistance
A&D CD MM1
D-90327 Nrnberg-Moorenbrunn
Fax.: +49 (911) 895-5907
From
Name:
Department
Location:
Telephone:
Internet address
very good
good
poor
Because:
approx. 5%
approx. 10%
other...........%
Suggestions/recommendations:
Page 7/7
CD-FE-I-023-V01-EN