Professional Documents
Culture Documents
1. Applications
Humidifiers & dehumidifiers
Air-conditioner
Humidity data loggers
Automotive climate control
Other applications
2. Specifications
DC 5.0 0.2V
DC 1.03.0 V
5% RH
2mA
0 to 99% RH
20 to 95% (100% RH intermittent)
< 3%RH
-20 to 70
0 to 50
MAX 2%RH
1.5%
Linearity
1 min
3 mm*2 mm
3. Reliability Test
No
Item
Method
Impact test
Vibration test
3
4
5
Heat
Resistance
Cool
Resistance
Humidity
Resistance
Temperature
cycle test
Requirment
No breakge,
nor racks
Should be
electrically
normal
Within
5%RH
Within
5%RH
Within
5%RH
Within
5%RH
Within
5%RH
Remark:
All standard f i gu res are based on hu mi di ty variation under
60%RH (at 25
Upon completion of all test, module will be left over under nominal
environment
And humidity for 24hours.
4.Typical Response at 25
STANDARD CHARACTERISTICS
%RH
10
20
30
40
50
60
70
80
90
OutpotV 0.74
0.95
1.31
1.68
2.02
2.37
2.69
2.99
3.19
Description:
1. Connect +5V DC power supply to the board.
2. Check for proper connections to avoid damage of board.
3.
The second and fourth pins are used to interface to controller port pins directly.
Precautions:
1.