You are on page 1of 1

No.

1
2
3
4
5
-

Reference building:
Building component
A [m2] R`m [m2*K/W]
Opaque surfaces of the external walls
1276
1.800
Glazing surfaces of the external walls
421.84
0.770
Terrace roof
271.39
2.900
Slab on the ground
1093
4.500
Floor in contact with exterior
71.24
4.500
Total
3062.2
-

[-] A*/R`m [W/K]


0.996
706.053
0.993
544.005
0.847
79.265
0.847
205.727
1.045
16.544
1551.594

No.
1
2
3
4
5
-

Real building:
Building component
A [m2] R`m [m2*K/W]
Opaque surfaces of the external walls
1276
2.436
Glazing surfaces of the external walls
421.84
0.854
Terrace roof
271.39
4.321
Slab on the ground
1093
5.033
Floor in contact with exterior
71.24
4.500
Total
3062.2
-

[-] A*/R`m [W/K]


1.035
542.143
0.993
490.500
0.891
55.961
0.891
193.496
1.045
16.544
1298.643

No.
1
2
3
4
5
-

Energy-optimised building:
Building component
A [m2] R`m [m2*K/W]
Opaque surfaces of the external walls
1276
4.384
Glazing surfaces of the external walls
421.84
0.850
Terrace roof
271.39
5.090
Slab on the ground
1093
5.737
Floor in contact with exterior
71.24
4.500
Total
3062.2
-

[-] A*/R`m [W/K]


1.035
301.245
0.993
492.808
0.891
47.507
0.891
169.751
1.045
16.544
1027.855

You might also like