Professional Documents
Culture Documents
SI UNITS
REV*
RFQ/RFP NO.
NuVista
Sour Water Booster
SERVICE
PROPOSAL
Montney
SITE:
1/23/2016
DATE
Montney
P-100
TAG
SIZE
PURCHASE
ANSI B73.1 or B73.2
TYPE:
REV.
VENDOR
MODEL
2 APPLICABLE TO:
OF
LOCATION
PROJECT
1 MANUFACTURER
PAGE
PROJECT NO.
CLIENT
DOC NO.
QTY
SERIAL
AS BUILT
NO. STAGES:
UNIT:
Single
GENERAL (3.1.1)
5
6 PUMP(S) TO OPERATE IN:
PARALLEL
SERIES
1 x 100%
7 CONFIGURATION:
P-100
PM-100
9 GEAR PROVIDED BY
MOTOR PROVIDED BY
Seller
TURBINE PROVIDED BY
10 GEAR MOUNTED BY
MOTOR MOUNTED BY
Seller
TURBINE MOUNTED BY
12
OPERATING CONDITIONS
13
m3/h
62.5
14 CAPACITY, NORMAL
15
OTHER
16
SUCTION PRESS.
17
DISCHARGE PRESSURE
18
DIFFERENTIAL PRESSURE
19
DIFFERENTIAL HEAD
20
PROCESS VARIATIONS
21
STARTING CONDITIONS
11.96
MAX.
RATED
kPag
75
m3/h
9.651
kPag
RATED
345
kPag
335.349
34.196
CONTINUOUS
23
INDOOR
HEATED
UNDER ROOF
OUTDOOR
UNHEATED
PARTIAL SIDES
GRADE
MEZZANINE
ELECTRICAL AREA CLASSIFICATION
1
2
Zone
Class
kPag
1.2192
NPSHA
WINTERIZATION REQ'D
SITE DATA
793
m
ALTITUDE
22 SERVICE:
LOCATION
INTERMITTENT (START/DAY)
LIQUID
27
28
PUMPING TEMPERATURE
10
NORM.
29
VAPOR PRESSURE
30
31
32
SPECIFIC HEAT, Cp
33
VISCOSITY
37.8
MAX.
(kPa abs)
C MIN.
@
MAX.
DUST
10
FUMES
kJ/kg 0C
0
10
cP @
C
cP
1.300
CORROSIVE/EROSIVE AGENT
36
CHLORIDE CONCENTRATION
H2S CONCENTRATION
STEAM DRIVERS:
MIN.
MAX.
kPag
kPag
MAX.
38
MIN.
23.1
C
%
MAX.
100
117963 mg/L
PPM
15 mg/L
PPM
FLAMMABLE
HAZARDOUS
VOLTAGE
HERTZ
PHASE
OTHER
STEAM UTILITY:
kPag
-
kPag
HEATING
CONTROL
C
SHUTDOWN
460
24VDC
24VDC
60
DRIVERS
ELECTRICITY:
39
COOLING WATER
PERFORMANCE
40
INLET TEMP.
rpm
MAX.
43
RATED POWER
kW
44
MIN.
PRESSURE
mm
EFFICIENCY
MIN RETURN
m3/h
m3/h
CHLORIDE CONCENTRATION
m3/h
TO
m3/h
47
m3/h
TO
48
m3/h
m
49
kW
50
51
52
53
54
REMARKS
THERMAL
kPag
STABLE
kPag
-
MAX ALLOW DP
kPag
WATER SOURCE
C
kPag
DESIGN
MAX RETURN
NORMAL
46
45
-40
OTHER
UTILITY CONDITIONS
MIN.
4.193
35
38 LIQUID
1.300
MAX VISCOSITY
kPa abs
MIN.
UNUSUAL CONDITIONS
1.22
34
37
RELATIVE HUMIDITY
Sour Produced Water
26 TYPE/NAME OF LIQUID
92.0
BAROMETER
24
25
IIA/IIB
Group
TROPICALIZATION REQ'D
PPM
MIN.
550
kPag
MAX.
830
kPag
REMARKS
dBA
< 85dBa
dBA
55
56
57
NOTE:
REV
A
BY VENDOR
DATE
BY
23-Jan-16
GJE
CHECKED
PROCESS
ELECT.
INSTR.
APPROVED
CLIENT
DESCRIPTION
Issued for Quotation
PAGE
PROJECT NO.
RFQ/RFP NO.
PROJECT
Sour Water Booster
MODEL
P-100
TAG
APPLICABLE STANDARD
OTHER
PUMP TYPE
OH2
BB1
VS1
VS6
LUBRICATION
OH3
OH4
BB2
VS2
VS6
BB3
VS3
______________
SPACER LENGTH
10
OH6
BB4
VS4
BB5
VS5
MAKE
ANSI
MODEL
13
SIZE
RATING
FACING
14
SUCTION
150#
RF
15
DISCHARGE
150#
RF
16
BAL. DRUM
POSITION
DRAIN
NON-GROUT
SIZE (NPS)
TYPE
PRESSURE GAUGE
22
TEMP. GAUGE
23
WARM-UP
APPENDIX H CLASS
24
BALANCE/LEAK-OFF
MATERIAL
D-1 (Note 2)
27
CENTERLINE
NEAR CENTERLINE
28
FOOT
SHAFT
31
32
INLINE
CASING SPLIT
AXIAL
CASING TYPE
33
34
35
COUPLING DIAPHRAGMS
REMARKS:
MULTIPLE VOLUTE
DIFFUSER
BETWEEN BEARINGS
BARREL
37
1965
kPag
37.8
2947.5
HYDROTEST PRESSURE
39
THRUST
REVIEW AND APPROVE THRUST BEARING SIZE
LUBRICATION: (2.10)
43
NUMBER
RADIAL
42
TYPE
BEARING
kPag
40
41
COUPLING SPACER/HUBS
RADIAL
OVERHUNG
CASE PRESSURE RATING
38
-29
IMPELLER
SINGLE VOLUTE
36
(APPENDIX M)
21
30
PACKAGER
REMARKS
NO.
VENT
DRIVER MFR.
18
20
mm
SERVICE FACTOR
NOZZLE CONNECTIONS
19
kW/100 rpm
CPLG RATING
11
29
CCW
44
GREASE
FLOOD
RING OIL
FLINGER
45
SHAFT
46
mm
47
mm
48
mm
49
mm
50
51
52 REMARKS
53
54
55
56
57
58
59
60
61
QTY
SIZE
26
1/23/2016
DATE
Montney
25
REV.
LOCATION
17
CONSTRUCTION
12
OF
VENDOR
SERVICE
1 MANUFACTURER
NuVista
CLIENT
REV*
DOC NO.
REMARKS:
ELECTRIC
STEAM
RFQ/RFP NO.
NuVista
OF
REV.
SERVICE
P-100
TAG
SEAL DATA
SEE ATTACHED API-682 DATA SHEET
NAME OF FLUID
FLOW RATE
SEAL VENDOR
SIZE
10
TYPE
11
TUBING
CARBON STEEL
PIPE
AUXILIARY FLUSH PIPING PLAN
VENDOR CODE
STAINLESS STEEL
53B
TUBING
CARBON STEEL
PIPE
PIPING ASSEMBLY
STAINLESS STEEL
13
TEMPERATURE
14
PRESSURE
kPa
THREADED
15
FLOW
m3/h
FLANGED
16
17
TOTAL LENGTH
mm
mm
CLEAR LENGTH
UNIONS
SOCKET WELDED
SEAL CONSTRUCTION
SLEEVE MATERIAL
20
GLAND MATERIAL
21
JACKET REQUIRED
GLAND TAPS
24
FLUSH (F)
DRAIN (D)
BARRIER/BUFFER (B)
25
QUENCH (Q)
COOLING (C)
LUBRICATION (G)
26
HEATING (H)
LEAKAGE
27
28
29
30
33
34
NAME OF FLUID
35
SPECIFIC HEAT, Cp
36
VAPOR PRESSURE
37
HAZARDOUS
FLOW RATE
38
TEMPERATURE REQUIRED
SUPPLY TEMPERATURE
46
47
48
NAME OF FLUID
49
VAPOR PRESSURE
50
HAZARDOUS
FLOW RATE
51
m3/h
m3/h
kPa
m3/h
kPa
m3/h
MAX.
m /h
MIN.
kPa
QUENCH
MAX.
kPa
MIN.
MAX.
MIN.
MAX.
C
C
STEAM PIPING
TUBING
kPa
m3/h
PIPE
REMARKS
53
56
57 REMARKS
@
kPa abs
FLAMMABLE
MIN.
INSTRUMENTATION
OTHER
m3/h
VIBRATION:
MAX.
m3/h
MIN.
kPa
MAX.
kPa
TEMPERATURE REQUIRED
MIN.
MAX.
54
55
PRESSURE REQUIRED
52
61
BARRIER/BUFFER FLUID
45
60
NO. OF RINGS
FLAMMABLE
OTHER
MIN.
43
59
kJ/kg 0C
41
58
SIZE
0
kPa abs
PRESSURE REQUIRED
42
TYPE
Pumpage
39
40
VENDOR
MAX.
32
44
PACKING DATA
31
Transmitter
TYPE
19
23
m3/h
22
QTY
SIZE
18
1/23/2016
VENDOR
MODEL
12
DATE
Montney
LOCATION
PROJECT
1 MANUFACTURER
PAGE
PROJECT NO.
CLIENT
REV*
DOC NO.
C
C
TRANSDUCER
NuVista
SERVICE
REV.
1/23/2016
DATE
Montney
P-100
TAG
QTY
SIZE
DOMESTIC
EXPORT
VENDOR
INSTRUMENTATION (CONTINUED)
TEMPERATURE AND PRESSURE
OF
LOCATION
MODEL
HORIZONTAL STORAGE
VERTICAL STORAGE
LOCATION
10
11
RFQ/RFP NO.
PROJECT
1 MANUFACTURER
PAGE
PROJECT NO.
CLIENT
REV*
DOC NO.
REMARKS:
12
MASSES
13
14
MOTOR DRIVEN
15
16
VENDOR
17
18
19
kW
rpm
HORIZONTAL
FRAME
VERTICAL
1.15
20
SERVICE FACTOR
21
22
VOLTS
HERTZ
23
TYPE
24
ENCLOSURE
TEFC
25
80%
26
TEMPERATURE RISE
27
28
29
INSULATION
30
STARTING METHOD
31
32
kg
kg
TOTAL MASS
kg
60
Squirrel-cage Induction
kg
MASS OF TURBINE
kg
MASS OF GEAR
kg
TOTAL MASS
kg
REMARKS
Class B
LUBE
UP
34
BEARINGS
RADIAL
36
37
MASS OF MOTOR
MASS OF GEAR
TURBINE DRIVEN
MASS OF BASEPLATE
PHASE
kg
kg
33
35
460
MASS OF PUMP
MASS OF BASEPLATE
THRUST
38
DOWN
TYPE
NUMBER
TYPE
NUMBER
39
40
41
MANUFACTURER'S STANDARD
42
43
PUMP
44
SURFACE PREPARATION
45
PRIMER
46
FINISH COAT
47
BASEPLATE (3.3.18)
48
SURFACE PREPARATION
49
PRIMER
50
FINISH COAT
51
52 REMARKS:
53
54
55
56
57
58
59
60
61
START-UP
SPECIFY
NORMAL MAINTENANCE
Packager shall provide start-up/commissioning spares.
Packager shall provide priced 2-yr spare list with bid.
PAGE
PROJECT NO.
RFQ/RFP NO.
CLIENT
SERVICE
1 MANUFACTURER
MODEL
2
3
NON-WIT.
PERFORMANCE (4.3.3)
11
NPSH (4.3.4.1)
12
13
14
15
17
18
REMOVE/INSPECT HYDRODYNAMIC
20
OBSERV.
16
19
WIT.
HYDROSTATIC (4.3.2)
10
21
22
23
24
CASING
25
OTHER
IMPELLER
SHAFT
26
27
28
MAG PARTICLE
LIQUID PENETRANT
29
RADIOGRAPHIC
ULTRASONIC
30
31
MAG PARTICLE
LIQUID PENETRANT
32
RADIOGRAPHIC
ULTRASONIC
33
34
(4.2.1.3)
35
36
MAG PARTICLE
LIQUID PENETRANT
RADIOGRAPHIC
ULTRASONIC
37
38
39
40
41
42
43
44
45 REMARKS
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
OF
(4.2.3.2)
(4.1.6)
REV.
DATE
1/23/2016
Montney
LOCATION
VENDOR
P-100
TAG
SIZE
REMARKS
7
8 TESTS
NuVista
PROJECT
REV*
DOC NO.
QTY
CENTRIFUGAL PUMP
REV*
1 MANUFACTURER
DOC NO.
PAGE
PROJECT NO.
RFQ/RFP NO.
NuVista
CLIENT
PROJECT
SERVICE
OF
REV.
DATE
Montney
LOCATION
VENDOR
MODEL
TAG
P-100
SIZE
NOTES
2
3 No.
4
2 Wetted materials shall be in accordance with NACE MR0175. Seller shall confirm material is suitable for the service and application.
5 Coupling shall be provided with spacer to allow removal without disturbing pump or seal. Non-spark coupling guard shall be provided, painted to indicate the hazard.
6 Seller to select dual pressurized seal design and primary seal plan. Plan 53B secondary proposed due to H2S content of pumped fluid, Seller to confirm.
10
11
12
13 10
14 11
15 12
16 13
17 14
18 15
19 16
20 17
21 18
22 19
23 20
24 21
25 22
26 23
27 24
28 25
29 26
30 27
31 28
32 29
33 30
34 31
35 32
36 33
37 34
38 35
39 36
40 37
41 38
42 39
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
1/23/2016
QTY