Table C-1: Roof level Uniform Load (kPa) Roof live load (flat or rise less than 33.3% slope) Total
0.75 0.75
Appendix D: Earthquake Load
Design Considerations *Based on actual Geotechnical Investigation Report provided by Earthdrill Geosystems, Inc. on June 2016 Occupancy category = IV (Standard Occupancy); Importance factor, I = 1 Seismic zone = 4; Seismic zone factor, Z = 0.4 Distance to seismic zone = 5.5 km Seismic source type = A (active and capable of producing magnitude 7.0) Near source factor: Na = 1.2, Nv = 1.6 Soil profile type = Sc (very dense soil and soft rock) Seismic coefficient: Ca = 0.48Na; Cv = 0.896Nv Ct = 0.0731 (for concrete) Overstrength factor, R = 3.5 (ordinary RC moment frames, NSCP 2010 table 20811A) Valley fault system Appendix D: Wind Load Design Considerations *The design shall conform to Section 207 WIND LOADS of NSCP 2010 Laguna Area (zone 2) Basic wind speed, V = 200kph
Surface roughness = C (207.5.6.2 Surface Roughness Categories, NSCP 2010) Exposure category = C (207.5.6.3 Surface Roughness Categories, NSCP 2010) Appendix E: Load Combinations U = 1.4D U = 1.2D + 1.6L U = 1.2D + 1.0L 1.0E U = 0.9D 1.0E U = 1.2D + 1.6W +1.0L Where: D = dead load L = live load E = earthquake load W = wind load