METODE PELAKSANAAN LOADING TEST

REV

BPP

Proyek
Lokasi

: Wisma Atlit Kemayoran


: Kemayoran - Jakarta

TABELPROSEDURPEMBACAANLATERALTEST

STEP

CYCLE

1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28

0
1
1
1
2
2
2
2
2
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4

%OF DESIGN
LOAD
0
25
50
25
0
50
75
100
75
50
0
50
100
125
150
125
100
50
0
50
100
150
175
200
150
100
50

HOLDING
TIME
0
15 minutes
20 minutes
10 minutes
10 minutes
10 minutes
15 minutes
20 minutes
10 minutes
10 minutes
10 minutes
10 minutes
15 minutes
20 minutes
10 minutes
10 minutes
10 minutes
10 minutes
10 minutes
20 minutes
20 minutes
20 minutes
60 minutes
60 minutes
10 minutes
10 minutes
10 minutes
30 minutes

LOADING INTERVAL IN
MINUTES
0
0-1-2-5-10-15
0-1-2-5-10-15-20
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10-15
0-1-2-5-10-15-20
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10-15
0-1-2-5-10-15-20
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10-15-20
0-1-2-5-10-15-20
0-1-2-5-10-15-20
0-1-2-5-10-15-20-30-40-50-60
0-1-2-5-10-15-20-30-40-50-60
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10
0-1-2-5-10-15-20-30

METODE PELAKSANAAN LOADING TEST


REV
Proyek
Lokasi

BPP

: Wisma Atlit Kemayoran


: Kemayoran - Jakarta

TABELPROSEDURPEMBACAANTENSILETEST
STEP

CYCLE

%OF DESIGN

HOLDING TIME

LOADING INTERVAL IN MINUTES

LOAD
1

25

"A"

50

1 hour

25

20 minutes

1 hour

50

20 minutes

0
0-10-20-30-40-50-60 (max 2 hours)
0-10-20-30-40-50-60
0-10-20
0-10-20-30-40-50-60
0-10-20

75

"A"

100

1 hour

0-10-20-30-40-50-60 (max 2 hours)

75

20 minutes

0-10-20

10

50

20 minutes

0-10-20

11

1 hour

12

50

20 minutes

0-10-20

13

100

20 minutes

0-10-20

14

125

"A"

15

150

1 hour

16

125

20 minutes

0-10-20

17

100

20 minutes

0-10-20

18

50

20 minutes

0-10-20

19

1 hour

20

50

20 minutes

0-10-20

21

100

20 minutes

0-10-20

22

150

20 minutes

0-10-20

23

175

"A"

0-10-20-30-40-50-60 (max 2 hours)

24

200

"B"

0-10-20-30-40-50-60 (for 4 hours)


and every 1 hour until 12 hours.
(Max. 24 hour)

25

150

1 hour

0-10-20-30-40-50-60

26

100

1 hour

0-10-20-30-40-50-60

27

50

1 hour

0-10-20-30-40-50-60

28

12 hours

0-10-20-30-40-50-60

0-10-20-30-40-50-60

0-10-20-30-40-50-60 (max 2 hours)


0-10-20-30-40-50-60

0-10-20-30-40-50-60

0-10-20-30-40-50-60 (for 4 hours)


and every 1 hour until 12 hours.

NOTE:
"A" Load is maintained for 1 hour or until settlement is not grather than 0.25 mm/hr with max 2 hours.