You are on page 1of 716

Siemens AG 2011

Low-Voltage Power Distribution


and Electrical Installation
Technology
Protection, Switching, Measuring and Monitoring Devices
Catalog LV 10.1 2011

Answers for infrastructure.

Siemens AG 2011

Related catalogs
Low-Voltage Power Distribution and
Electrical Installation Technology
Protection, Switching, Measuring and
Monitoring Devices
Order No.:
E86060-K8250-A101-A1-7600

Switchboards and Distribution Systems


Order No.:
E86060-K8260-A101-A1-7600

Contents

LV 10.1

LV 10.2

Switchboards SIVACON 8PS busbar trunking systems


SIVACON 8MC, 8MF Cubicle Systems SIVACON 8MR, 8ME
Cubicle Air-Conditioning Distribution Boards Terminal
blocks

GAMMA Building Management Systems ET G1


Order No.:
E86060-K8230-A101-B5-7600

ET D1

Display and control units Output devices Input devices


Combination devices Lighting Sun protection, anti-glare
protection, utilization of daylight Heating, cooling, ventilation,
air-conditioning Load management Safety Quick-assembly systems Gateways, interface converters Physical
sensors Control and automation devices System products
System accessories Counters Radio system - GAMMA wave
KNX-Radio Radio system - EnOcean

DELTA Switches and Socket Outlets


Order No.:
PDF only: (E86060-K8240-A101-B4-7600)

Air circuit breakers Molded case circuit breakers Miniature


circuit breakers Residual current protective devices Fuse
systems Overvoltage protection devices Switch
disconnectors Switching devices Transformers, Bells and
Socket Outlets Busbar Systems Measuring devices and
E-counters Monitoring devices Software

i-system DELTA line DELTA vita DELTA miro DELTA profil


DELTA style DELTA natur m-system Surface-mounting
product range Switching/pushbutton control/dimming
Motion detectors Shutter/blind controls Room temperature
controllers Data and communication systems Remote
control systems Smoke detectors GAMMA bus coupling
units

SIVACON S4
Power Distribution Boards
Order No.:
E80003-A10-R112-X-7600

LV 56

Power distribution boards Standard configurations Cubicles, supporting structure and enclosures Busbar system
Assembly kits for switching devices Covers, modular doors,
mounting plates, 19" rack Internal separation Air-conditioning products Accessories

SIVACON 8PS
Busbar Trunking Systems
CD-L, BD01, BD2 up to 1250 A
Order No.:
E86060-K1870-A101-A5-7600

LV 70

Busbar Trunking Systems, Overview CD-L System


(25 A ... 40 A) BD 01 System (40 A ... 160 A)
BD2 System (160 A ... 1250 A)

Interactive Catalog
Order No.:
E86060-D4001-A510-C9-7600

CA 01

All products of automation technology, drive technology,


low-voltage power distribution and electrical installation
technology, including those in the catalogs listed above

Industry Mall
Internet:
www.siemens.com/industrymall

All products of automation technology, drive technology,


low-voltage power distribution and electrical installation
technology, including those in the catalogs listed above

Catalog PDF
Internet:
www.siemens.com/lowvoltage/infomaterial

All catalogs for low-voltage power distribution and electrical


installation technology can be downloaded as PDF files.

Trademarks

Technical Support

All product designations may be registered trademarks or


product names of Siemens AG or other supplying companies.
Third parties using these trademarks or product names for their
own purposes may infringe upon the rights of the trademark
owners.

Expert advice on technical


questions with a wide range
of demand-optimized services for all our products and
systems.

Further information about low-voltage power distribution and


electrical installation is available on the Internet at:

www.siemens.com/
lowvoltage/technical-support

www.siemens.com/lowvoltage

Siemens LV 10.1 2011

Siemens AG 2011

Low-Voltage Power Distribution


and Electrical Installation
Technology
Protection, Switching, Measuring
and Monitoring Devices

Air Circuit Breakers

Molded Case Circuit Breakers

Miniature Circuit Breakers

Residual Current Protective Devices

Fuse Systems

Overvoltage Protection Devices

Switch Disconnectors

Switching Devices

Transformers, Bells and Socket Outlets

The products and


systems listed in this
catalog are developed
and manufactured in
accordance with a
VDE-certified quality
management system
complying with
EN ISO 9001:2000.

Catalog LV 10.1 2011

Catalog LV 10.1 2011

Busbar Systems

10

Measuring Devices and E-counters

11

Refer to the Industry Mall for current updates of


this catalog
www.siemens.com/industrymall

Monitoring Devices

12

The products in this catalog can also be found


in the interactive catalog CA 01.
Order No.:
E86060-D4001-A510-C9-7600

Software

13

Power Distribution Boards

14

SIVACON 8PS Busbar Trunking Systems

15

SIVACON 8MC, 8MF Cubicle Systems

16

SIVACON 8MR, 8ME Cubicle


Air-Conditioning

17

Distribution Boards

18

Terminal Blocks

19

Appendix

20

Supersedes:
Catalog ET B1 2010
Catalog News ET B1 N November 2009
Catalog LV 1 2010

Siemens AG 2010

Catalog LV 10.2 2011

Contact your local Siemens sales office


for further information

Siemens AG 2011

Innovation is the key to success

Energy-efficiency and environmental


protection is our business principle

Customer focus as USP

We continue to invest heavily in the research and development of new technologies. We have our own experimental and
test laboratories where we carry out intensive basic research on the climate in
buildings and on fire, gas and explosion
protection. This gives us the experience
and the opportunity to create solutions
that continuously flow into our new products and systems. At special test premises,
such as airport buildings and hospital
premises, we test the interoperability of
the individual systems. This empirical data
is incorporated into industry-specific solutions that continually set new standards
and underscore our claim to technological
leadership.

And this business principle applies crosscompany and to each and every employee: We are committed to environmental protection and the careful use of resources. Since 1994, we have been
involved in more than 1300 energy efficiency projects, which have jointly contributed to the saving of around 1.5 billion
euro in energy costs and reduced the annual CO2 burden on the environment by
approx. 700 000 t. So, as you can see, intelligent solutions in technical infrastructures benefit not only the owners and operators of buildings, but also those who
have nothing to do with them.

This is not just a soundbite, we make every effort to ensure close customer relations. We have in-depth knowledge of
their business and involve them in the development of our innovations. Our skills
make us an expert provider of industryspecific solutions and services, a preferred
partner during the life cycle of a building and allow us to enjoy mutual growth with
our customers.

Siemens LV 10.1 2011

Siemens AG 2011

Answers for infrastructure

Siemens Industry meets the great challenges of our time


head on. With solutions for technical infrastructure in
industrial and non-residential buildings, residential
buildings and public facilities, Siemens ensures enhanced
comfort and energy efficiency in buildings, as well as the
protection and safety of persons, property and business
processes. As a longstanding and professional partner with
all-round expertise in the industry sector, we offer tailored
solutions that generate sustainable added value for our
customers.

Gain a competitive edge with integrated building solutions


Total Building Solutions means more innovation from a single source for enhanced functionality under one roof.
When it comes to delivering turnkey buildings equipped with cutting edge power
distribution, building automation and
safety and fire-protection equipment from
a single source, Siemens is in a league of
its own. And just to show that we are
more than just the sum of our parts, our
portfolio includes:

Low-voltage power distribution


Switchboards, busbar trunking
systems, distribution boards,
circuit breakers, switch disconnectors,
low-voltage circuit protection, building
management systems, switches and
socket outlets
Building automation
Heating, ventilation and air-conditioning controls, overall energy solutions
offering guaranteed savings
Safety solutions
Access control, video monitoring, burglar protection, alarm control centers,
operation of alarm control centers

Fire protection
Fire alarms, alerting, evacuation, extinction and complete fire protection
solutions
Take a closer look at all the options available from Siemens. Check out the opportunities our products provide and discover
how we can help you sustainably enhance
your competitive edge.

Siemens LV 10.1 2011

Siemens AG 2011

The right product for every need


Our portfolio comprises switchboards,
busbar trunking systems, distribution
boards, measuring devices, circuit
breakers and switch disconnectors, circuit
protection devices, building management
systems, switches and socket outlets. The
consistency, modularity and intelligence
of our components and systems offer you
numerous advantages throughout their
service life and wherever you are in the
world. We deliver trendsetting designs
and innovative functions in unique quality, developed in accordance with the
applicable international standards.

Siemens LV 10.1 2011

Siemens AG 2011

Consistent, safe and intelligent


power distribution
Whether in industrial plants or in buildings: Every technical
system depends on a reliable supply of electric power. Even a
short power failure may have serious consequences. For this
reason, you need products and systems which cope with every
eventuality and always keep you on the safe side. Our portfolio is
the broadest world-wide, covering everything from switchboards
to socket outlets.
We will be glad to provide you with extensive support from the
initial information to the operation. Convince yourself of the
possibilities we offer you.

Making efficient use of energy

Excellent support

Top quality standards world-wide

The consistent concept behind the


communication-capable components of
our low-voltage power distribution range
forms a sound basis for the measurement,
indication, evaluation and optimization of
power flows, thus enabling professional
energy management for more cost-effectiveness. At the same time our intelligent
building management systems, e.g. for
lighting and heating, help to remarkably
reduce power consumption.

As a competent and reliable partner we


offer you comprehensive support from
initial information, planning, configuration and ordering through to commissioning, operation and technical support. We
know the requirements to be met in your
area of work and day-to-day business. On
this basis we provide you with the type of
flexible and efficient help that allows you
to concentrate fully on your customers
and their needs.

Opting for us puts you on the safe side:


Whether it is our workmanship, the
materials we use or the operability and
functionality of our products
we guarantee top standards of quality
world-wide.

Siemens LV 10.1 2011

Siemens AG 2011

New developments

 page 3/6

Auxiliary switches and fault signal contacts with TEST button for miniature
circuit breakers
 page 3/31

Busbar system according to UL 508

 page 3/45

Auxiliary switches for miniature circuit breakers according to UL 489


 page 3/52

Selective main miniature circuit breaker, SHU

 page 3/56

SIQUENCE residual current protective devices, Type B+

5SL miniature circuit breakers

Siemens LV 10.1 2011

 page 4/9

Siemens AG 2011

Compact fuse holders for motor starter combinations

 page 5/24

 page 5/64

3NJ62 switch disconnectors with fuses - fuse monitoring,


DC version

 page 7/64

3NP1 fuse switch disconnectors

 page 7/89

Light indicators with LEDs

 page 8/14

DC isolators

 page 8/20

SENTRON PAC 1500 E-counters

 page11/6

Photovoltaic fuses

EFM10 and EFM20/25 electronic fuse monitors


 page 7/65

Siemens LV 10.1 2011

Siemens AG 2011

Expansion modules for E-counters

 page11/13

LAN couplers

 page 11/21

SENTRON PAC 4200

 page 11/28

SENTRON PAC 4DI/2DO expansion modules

 page 11/31

SENTRON ATC5300

 page 12/8

Residual current monitoring, RCM

 page12/10

ALPHA SELECT V6.1project management software

 page 13/7

SENTRON Powermanager

 page13/16

Siemens LV 10.1 2011

Siemens AG 2011

Our added extra

Build on a sound basis

Low-voltage power distribution on the Web

With our basic and advanced courses, you can lay the foundations for your business success. Expert lecturers provide you
with the necessary theoretical and practical knowledge in our
modern training center in Regensburg. Dynamic and easy-tounderstand training with multimedia teaching equipment and
many practical examples. Available in German and English. If
required, we also provide training in-house or in one of our local Siemens branches.

Visit us on the Internet. You will find comprehensive information on our products SIVACON switchboards, busbar trunking systems, ALPHA distribution boards, SENTRON circuit
breakers and switch disconnectors, BETA low-voltage circuit
protection, GAMMA building management systems and
DELTA switches and socket outlets at:
www.siemens.com/lowvoltage

The range of courses extends through low-voltage power distribution to electrical installation technology. You will get to know
our entire portfolio of products and their application. Step-bystep we will familiarize you with the entire spectrum of modern
installation options, thus opening up a whole new world of
business opportunities.
And by the way: in 1991, the training center in Regensburg
became the first certified training center in the world to offer
KNX courses, and it is the only manufacturer training center to
teach the entire range of KNX-certified courses in both German and English.
For details of our current range of courses, please visit our
website at:
www.siemens.com/lowvoltage/training

Comprehensive support
We can help you with all your requirements: contact us if you
have any queries regarding our products, the planning of your
electrical installation or how to obtain technical documentation.
Just give us a call:
Tel.: +49 (911) 895 7222
Fax: +49 (911) 895 7223
www.siemens.com/lowvoltage/technical-support
Tender specification texts
For your support, we offer you a comprehensive range of
specification texts:
www.siemens.com/specifications

Siemens LV 10.1 2011

Siemens AG 2011

Much more
than a catalog.
The Industry Mall.

Selecting
Find your products in the structure tree, in the new "Bread-crumb"
navigation or with the integral search machine with expert functions.
Electronic configurators are also integrated into the Mall. Enter the
various characteristic values and the appropriate product will be displayed with the relevant order numbers. You can save configurations,
load them and reset them to their initial status.

You have a catalog in your hands that will serve


you well for selecting and ordering your products.
But have you heard of the electronic online catalog (the Industry Mall) and all its benefits? Take a
look around it sometime:

Ordering
You can load the products that you have selected in this way into the
shopping basket at a click of the mouse. You can create your own templates and you will be informed about the availability of the products
in your shopping cart. You can load the completed parts lists directly
into Excel or Word.

www.siemens.com/industrymall
Delivery status
When you have sent the order, you will receive a short e-mail confirmation which you can print out or save. With a click on "Carrier", you
will be directly connected to the website of the carrier where you can
easily track the delivery status.
Added value due to additional information
So you have found your product and want more information about it?
In just a few clicks of the mouse, you will arrive at the image data base,
manuals and operating instructions. Create your own user documentation with My Documentation Manager.
Also available are FAQs, software downloads, certificates and technical data sheets as well as our training programs. In the image database
you will find, depending on the product, 2D/3D graphics, dimension
drawings and exploded drawings, characteristic curves or circuit
diagrams which you can download.
Convinced? We look forward to your visit!

10

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


1/2

Introduction

1/6
1/7
1/11
1/15
1/19
1/23
1/29

3WL Air Circuit Breakers/


Non-Automatic Air Circuit Breakers
up to 6300 A (AC)
Introduction
3-pole, fixed-mounted versions
3-pole, withdrawable versions
4-pole, fixed-mounted versions
4-pole, withdrawable versions
Options
Accessories and spare parts

1/51
1/52

3WL Non-Automatic Air Circuit


Breakers up to 4000 A (DC)
3- and 4-pole, fixed-mounted
versions
3-pole, withdrawable versions
4-pole, withdrawable versions

1/53

Accessories and spare parts

Ch.12

SENTRON Transfer Control


Devices for ATSE

1/50

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


Introduction

Overview

Size I

Size III

Size II

Air circuit breakers


3WL air circuit breakers/non-automatic air circuit breakers
up to 6300 A (AC)
Size
Rated current In

Number of poles
Rated operational
voltage Ue

V AC
V DC

Rated ultimate
short-circuit breaking
capacity at 500 V AC

kA

Endurance

3WL non-automatic air circuit breakers


up to 4000 A (DC)
I, II, III

II

630, 800, 1000, 1250,


1600, 2000, 2500, 3200, 4000,
5000, 6300

1000, 2000, 4000

3-pole, 4-pole

3-pole, 4-pole

... 690/1000/1150
--

-... 1000

Size I

Size II

Size III

55/66

66/80/100

100/150 (3-pole),
130 (4-pole)

30/25/20
(at 300/600/1000 V DC)

15000

10000

15000

Operating 20000
cycles

Mounting position

30 30

30 30

NSE0_00062a

NSE0_00061a

Degree of protection
With cover
Without cover
(with door sealing frame)

30 30

30 30

NSE0_00061a

IP55
IP41

NSE0_00062a

IP55
IP41

Dimensions 3-/4-pole
460/590

704/914

460/590

434
291

434
291

434
291

434
291

Withdrawable

H mm
D mm

465.5
471

465.5
471

465.5
471

465.5
471

NSE0_01107a

NSE0_01108a

ETU15B1)

Type

NSE0_01109a

320/410

H mm
D mm

ETU25B

ETU27B

ETU45B

ETU76B

NSE0_01106a

NSS0_00535

W mm
Fixed
mounting

Rating Plug

NSE0_01111a

Electronic releases for SENTRON 3WL circuit breakers


Overload protection

Short-time delayed
short-circuit protection

--

Instantaneous
short-circuit protection

Neutral conductor protection

--

--

Ground-fault protection

--

--

Zone Selective Interlocking

--

--

--

LCD, 4-line

--

--

--

--

LCD, graphic

--

--

--

--

Communication through
PROFIBUS DP

--

--

--

Measurement function Plus

--

--

--

Selectable parameter sets

--

--

--

--

Parameters freely programmable

--

--

--

--

CubicleBUS

--

--

--

Standard
-- Not available
Optional

3WL air circuit breakers/non-automatic air circuit breakers


according to UL 489 up to 5000 A, see Catalog LV 16.

1)

SENTRON transfer control devices for ATSE, see chapter


"Monitoring Devices".

ETU15B cannot be used with 3WL circuit breakers, size III.

1/2

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


Introduction

Switching capacity
Size

II

Type

3WL11

3WL12

Switching capacity class

III

3WL13

C
3-pole

C
4-pole

Short-circuit breaking capacity


Rated operational voltage Ue
up to 415 V AC
Icu

kA

55

66

66

80

100

100

150

130

Ics

kA

55

66

66

80

100

100

150

130

Icm

kA

121

145

145

176

220

220

330

286

Icu

kA

55

66

66

80

100

100

150

130

Ics

kA

55

66

66

80

100

100

150

130

Icm

kA

121

145

145

176

220

220

330

286

Icu

kA

42

50

50

75

85

85

150

130

Ics

kA

42

50

50

75

85

85

150

130

Icm

kA

88

105

105

165

187

187

330

286

--

--

--

50

50

704)

704)

Rated operational voltage Ue


up to 500 V AC

Rated operational voltage Ue


up to 690 V AC

Rated operational voltage Ue


up to 1000 V/1150 V AC
kA

Icu

--

704)

Ics

kA

--

--

--

--

50

50

704)

Icm

kA

--

--

--

--

105

105

1544)

1544)

55
42
29.5
24

66
50
35
29

66
55
39
32

80
66
46
37

100
80
651)/702)
501)/652)

100
100
80
65

100
100
80
65

100
100
80
65

Rated short-time withstand current Icw


of the circuit breakers3)
0.5 s
1s
2s
3s

kA
kA
kA
kA

Short-circuit breaking capacity Icc


of the non-automatic air circuit breakers
Up to 500 V AC

kA

55

66

66

80

100

100

100

100

Up to 690 V AC

kA

42

50

50

75

85

85

100

100

Up to 1000 V /1150 V AC

kA

--

--

--

--

504)

504)

Size

II

Type

3WL12

Switching capacity class

DC

704)

704)

DC

Short-circuit breaking capacity


Up to 220 V DC
Up to 300 V DC
Up to 600 V DC
Up to 1000 V DC

Icc
Icc
Icc
Icc

kA
kA
kA
kA

35
30
25
20

Rated short-time withstand current Icw


0.5 s
1s
2s
3s

kA
kA
kA
kA

-355)/306)/257)/208)
---

Circuit breaker with ECO switching capacity N

Circuit breaker with standard switching capacity S

Circuit breaker with high switching capacity H

Circuit breakers with very high switching capacity C

DC

1)

Size II with In max  2500 A.

2)

Size II with In max = 3200 A and In max = 4000 A.

3)

At a rated voltage of  690 V the Icw value of the circuit breaker cannot be
greater than the Icu or Ics value at 690 V.

4)

Rated operational voltage Ue = 1150 V.

5)

At Ue = 220 V DC.

6)

At Ue = 300 V DC.

7)

At Ue = 600 V DC.

8)

At Ue = 1000 V DC.

Non-automatic air circuit breakers with DC switching


capacity
These breaking capacities are indicated in the corresponding tables by the symbols shown on orange backgrounds.

Siemens LV 10.1 2011

1/3

Siemens AG 2011

Air Circuit Breakers


Introduction
SENTRON 3WL:
Superior individual products integrated into uniform power distribution systems - up to and including industry-specific industrial and infrastructure solutions

6
7

8
5

9
1
25

21

10

19
22

11

23
12

24

18

13

14
20

16
15

$
%
&
(
)
*
+
,
.
/
0
1
2
3

Guide frame (pages 1/30 to 1/33)


Main circuit connection front, flange, horizontal, vertical
(pages 1/28, 1/45 and 1/46)
Position signaling switch (pages 1/26 and 1/38)
Grounding contact, leading (page 1/42)
Shutters (pages 1/26 and 1/41)
COM15 PROFIBUS module or COM16 MODBUS module
(pages 1/26 and 1/44)
External CubicleBUS module (page 1/43)
Closing solenoid, auxiliary release (pages 1/23, 1/25 and 1/40)
Auxiliary cable connection system (pages 1/27 and 1/39)
Auxiliary switching block (pages 1/23 and 1/40)
Door sealing frame (pages 1/25 and 1/41)
Interlocking set for mechanical ON/OFF (page 1/35)
Transparent panel, function insert (page 1/35)
EMERGENCY-STOP pushbutton, key operated (page 1/38)
Motorized operating mechanism (pages 1/25 and 1/40)

1/4

Siemens LV 10.1 2011

4
5
6
7
8
9
:
;
<
=

Operating cycles counter (pages 1/25 and 1/38)


Breaker status sensor (BSS) (pages 1/26 and 1/44)
Protective device with device holder, electronic release (ETU)
(page 1/34)
Remote reset solenoid (pages 1/25 and 1/35)
Breaker data adapter (BDA) (page 1/43)
4-line display (page 1/34)
Ground-fault protection module (page 1/34)
Rated current module (pages 1/24 and 1/34)
Measurement function module (pages 1/26 and 1/34)
Circuit breaker (pages 1/7 to 1/22)

NSE0_01887b

17

Siemens AG 2011

Air Circuit Breakers


Introduction
Communication-capable circuit breakers (with ETU45B or ETU76B electronic release)

21

Ethernet

19
20

PROFIBUS

14

22

15

16

18

CubicleBUS

10
1

17

11

12
3

NSE0_01105i

13

SENTRON 3VL

12 Electronic ETU release

Electronic LCD ETU release

13 Measurement function Plus

Electronic ETU release

14 ZSI module

COM10 PROFIBUS module complete with ZSI

15 Digital output module with relay contacts

COM20 PROFIBUS module1) complete with ZSI

16 Digital output module with relay contacts, configurable

Breaker Data Adapter (BDA)

17 Analog output module

BDA Plus with Ethernet interface

18 Digital input module

Browser-capable input and output device (e.g. notebook)

19 Switch ES Power on PC

SENTRON 3WL

20 PLC e.g. SIMATIC S7

10 COM15 PROFIBUS module2)

21 SIMATIC powerrate

11 Breaker Status Sensor (BSS)

22 SENTRON PAC

1)
2)

For a MODBUS connection the COM21 module is required.


For a MODBUS connection the COM16 module is required.

Features
Coordinated communication concept using the PROFIBUS DP
or MODBUS, ranging from 16 A to 6300 A with SENTRON 3VL
and SENTRON 3WL
The high level of modularity of circuit breakers and accessories
allows easy retrofitting of all communication components
Significant additional benefits for the switchboard due to the
possibility of linking up external input and output modules to
the circuit breaker-internal CubicleBUS of the SENTRON 3WL

Communication:
For air circuit breakers with optional communication function
(ETU45B or ETU76B electronic release) see pages 1/7 to 1/22.
For accessories see pages 1/43 and 1/44.
For more information see also chapters "Measuring Instruments and E-Counters" and "Software".

Innovative software products for parameterization, operation,


monitoring, and diagnostics of SENTRON circuit breakers,
both locally or via PROFIBUS DP, MODBUS or Ethernet/
Intranet/Internet
Complete integration of the SENTRON circuit breakers into the
Totally Integrated Power and Totally Integrated Automation
solutions

Siemens LV 10.1 2011

1/5

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Introduction
Fast and reliable parameterization
Timely information and response can prevent plant
stoppages
Effective diagnostics management
Measured values are the basis for efficient load management,
for drawing up power demand profiles and for assigning
energy to cost centers
Preventive maintenance reduces the risk of expansive plant
down-times

Benefits
Low space requirements
The SENTRON 3WL devices require very little space. Size I devices (up to 1600 A) fit into a 400 mm wide switchgear panel.
Size III devices (up to 6300 A) are the smallest of their kind and
with their construction width of 704 mm fit into a 800 mm wide
switchgear panel.
Modular design
Components like auxiliary releases, motorized operating mechanisms, electronic releases, current sensors, auxiliary circuit signaling switches, automatic reset devices, interlocks and engagement operating mechanisms can all be exchanged or
retrofitted at a later stage, thus allowing the circuit breaker to be
adapted to new, changing requirements.
The main contact elements can all be replaced in order to increase the endurance of the circuit breaker.

Applications
As incoming-feeder, distribution, tie, and outgoing-feeder circuit breakers in electrical installations.
For switching and protecting motors, capacitors, generators,
transformers, busbars and cables.
Due to the reinforced use of electronic control systems, the demands made on air circuit breakers in terms of operator control
and monitoring of network processes have increased.

Retrofittable modules for electronic releases


Modularity is one of the main features of the new SENTRON 3WL
circuit breakers.
Special LCDs, ground-fault modules, rated current modules and
communication modules for the electronic releases are available
for fast and easy retrofitting and adaptation to changing requirements.

The extensive, coordinated SENTRON range of devices covers


all applications between 16 A and 6300 A with compact and
open circuit breakers.

Communication

Standards

The use of modern communication-capable circuit breakers


opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects
to be achieved.

SENTRON 3WL circuit breakers comply with:


IEC 60947-2
EN 60947-2
Climate-proof according to IEC 60068-2-30.

The AC devices are available as circuit breakers and non-automatic air circuit breakers. DC devices are only available as nonautomatic air circuit breakers.

Versions with UL 489 also available, see Catalog LV 16.


For further standards, see Appendix.

Conductor cross-sections
Size
Type
Permissible load
At rear horizontal main
connections

Up to 55 C (Cu bare)
Up to 60 C (Cu bare)1)
Up to 70 C (Cu black
painted)1)

Main conductor
minimum
cross-sections

Copper bars,
bare
Copper bars,
painted black

I
Up to
3WL11 10
A 1000
A 1000
A 1000

II
3WL11 12 3WL11 16 3WL12 08 3WL12 10 3WL12 12 3WL12 16 3WL12 20
1250
1250
1210

1600
1600
1490

800
800
800

1000
1000
1000

1250
1250
1250

1600
1600
1600

2000
2000
2000

Unit(s) 1
mm2 60 10

2
40 10

2
50 10

1
50 10

1
60 10

2
40 10

2
50 10

3
50 10

Unit(s) 1
mm2 60 10

2
40 10

2
50 10

1
50 10

1
60 10

2
40 10

2
50 10

3
50 10

Size

II

Type

3WL12 25 3WL12 32 3WL12 40 3WL13 40 3WL13 50 3WL13 63

Permissible load

Up to 55 C (Cu bare)
Up to 60 C (Cu bare)1)
Up to 70 C (Cu black
painted)1)

Main conductor
minimum
cross-sections

Copper bars,
bare
Copper bars,
painted black

A 2500
A 2500
A 2280

3200
3020
2870

3950
3810
3600

4000
4000
4000

5000
5000
5000

5920
5810
5500

Unit(s) 2
mm2 100 10

3
100 10

4
120 10

4x
100 x 10

6x
100 x 10

6x
120 x 10

Unit(s) 2
mm2 100 10

3
100 10

4
4
100 102) 100 10

6
100 10

6
120 10

1)

ETU76B with graphics display can be used up to max. 55 C.

2)

Minimum main conductor cross-sections for 4-pole withdrawable circuit


breakers: 4 120 10 mm.

1/6

Siemens LV 10.1 2011

III

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, fixed-mounted versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
For Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@32-....
3WL11 08-2@@32-....
3WL11 10-2@@32-....
3WL11 12-2@@32-....
3WL11 16-2@@32-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@32-....
3WL12 10-2@@32-....
3WL12 12-2@@32-....
3WL12 16-2@@32-....
3WL12 20-2@@32-....
3WL12 25-2@@32-....
3WL12 32-2@@32-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@31-....
3WL11 08-2@@31-....
3WL11 10-2@@31-....
3WL11 12-2@@31-....
3WL11 16-2@@31-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@31-....
3WL12 10-2@@31-....
3WL12 12-2@@31-....
3WL12 16-2@@31-....
3WL12 20-2@@31-....
3WL12 25-2@@31-....
3WL12 32-2@@31-....
3WL12 40-2@@31-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@33-....
3WL11 08-2@@33-....
3WL11 10-2@@33-....
3WL11 12-2@@33-....
3WL11 16-2@@33-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@33-....
3WL12 10-2@@33-....
3WL12 12-2@@33-....
3WL12 16-2@@33-....
3WL12 20-2@@33-....
3WL12 25-2@@33-....
3WL12 32-2@@33-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@34-....
3WL11 08-2@@34-....
3WL11 10-2@@34-....
3WL11 12-2@@34-....
3WL11 16-2@@34-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@34-....
3WL12 10-2@@34-....
3WL12 12-2@@34-....
3WL12 16-2@@34-....
3WL12 20-2@@34-....
3WL12 25-2@@34-....
3WL12 32-2@@34-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/10.
* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/7

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
For Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@32-....
3WL11 08-3@@32-....
3WL11 10-3@@32-....
3WL11 12-3@@32-....
3WL11 16-3@@32-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@32-....
3WL12 10-3@@32-....
3WL12 12-3@@32-....
3WL12 16-3@@32-....
3WL12 20-3@@32-....
3WL12 25-3@@32-....
3WL12 32-3@@32-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@31-....
3WL11 08-3@@31-....
3WL11 10-3@@31-....
3WL11 12-3@@31-....
3WL11 16-3@@31-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@31-....
3WL12 10-3@@31-....
3WL12 12-3@@31-....
3WL12 16-3@@31-....
3WL12 20-3@@31-....
3WL12 25-3@@31-....
3WL12 32-3@@31-....
3WL12 40-3@@31-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@33-....
3WL11 08-3@@33-....
3WL11 10-3@@33-....
3WL11 12-3@@33-....
3WL11 16-3@@33-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@33-....
3WL12 10-3@@33-....
3WL12 12-3@@33-....
3WL12 16-3@@33-....
3WL12 20-3@@33-....
3WL12 25-3@@33-....
3WL12 32-3@@33-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@34-....
3WL11 08-3@@34-....
3WL11 10-3@@34-....
3WL11 12-3@@34-....
3WL11 16-3@@34-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

43.000
43.000
43.000
43.000
43.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@34-....
3WL12 10-3@@34-....
3WL12 12-3@@34-....
3WL12 16-3@@34-....
3WL12 20-3@@34-....
3WL12 25-3@@34-....
3WL12 32-3@@34-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/10.

* You can order this quantity or a multiple thereof.

1/8

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@32-....
3WL12 10-4@@32-....
3WL12 12-4@@32-....
3WL12 16-4@@32-....
3WL12 20-4@@32-....
3WL12 25-4@@32-....
3WL12 32-4@@32-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@32-....
3WL13 50-4@@32-....

1
1

1 unit
1 unit

103
103

82.000
82.000

Vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@31-....
3WL12 10-4@@31-....
3WL12 12-4@@31-....
3WL12 16-4@@31-....
3WL12 20-4@@31-....
3WL12 25-4@@31-....
3WL12 32-4@@31-....
3WL12 40-4@@31-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000
85.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@31-....
3WL13 50-4@@31-....
3WL13 63-4@@31-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

82.000
82.000
90.000

Front main circuit connection, single hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@33-....
3WL12 10-4@@33-....
3WL12 12-4@@33-....
3WL12 16-4@@33-....
3WL12 20-4@@33-....
3WL12 25-4@@33-....
3WL12 32-4@@33-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

III

4000

4000

100 B

3WL13 40-4@@33-....

1 unit

103

82.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

56.000
56.000
56.000
56.000
56.000
59.000
64.000

1 unit

103

82.000

Front main circuit connection, double hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@34-....
3WL12 10-4@@34-....
3WL12 12-4@@34-....
3WL12 16-4@@34-....
3WL12 20-4@@34-....
3WL12 25-4@@34-....
3WL12 32-4@@34-....

III

4000

4000

100 B

3WL13 40-4@@34-....

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI6)
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/10.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/9

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 150 kA at 500 V,


very high switching capacity C

kA

Order No.
Order No. supplements,
see page 1/23

C
Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

DT

Weight
per PU
approx.

kg

Horizontal main circuit connection


III
III

4000
5000

4000
5000

150 B
150 B

3WL13 40-5@@32-....
3WL13 50-5@@32-....

1
1

1 unit
1 unit

103
103

82.000
82.000

4000
5000
6300

150 B
150 B
150 B

3WL13 40-5@@31-....
3WL13 50-5@@31-....
3WL13 63-5@@31-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

82.000
82.000
90.000

Vertical main circuit connection


III
III
III

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
Footnotes for pages 1/7 to 1/10:
1)

The rated current is determined by the rated current module. For the standard version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 1/24.

3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 1/34.

2)

For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 1/3.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 1/34.

5)

ETU45B and ETU76B with ground-fault protection module GFM AT (alarm


and tripping), see page 1/34.

6)

ETU15B cannot be used with 3WL circuit breakers, size III.

* You can order this quantity or a multiple thereof.

1/10

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, withdrawable versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
For Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@35-....
3WL11 08-2@@35-....
3WL11 10-2@@35-....
3WL11 12-2@@35-....
3WL11 16-2@@35-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

45.000
45.000
45.000
45.000
45.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@35-....
3WL12 10-2@@35-....
3WL12 12-2@@35-....
3WL12 16-2@@35-....
3WL12 20-2@@35-....
3WL12 25-2@@35-....
3WL12 32-2@@35-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

60.000
60.000
60.000
60.000
60.000
63.000
68.000

With guide frames, horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@36-....
3WL11 08-2@@36-....
3WL11 10-2@@36-....
3WL11 12-2@@36-....
3WL11 16-2@@36-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@36-....
3WL12 10-2@@36-....
3WL12 12-2@@36-....
3WL12 16-2@@36-....
3WL12 20-2@@36-....
3WL12 25-2@@36-....
3WL12 32-2@@36-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@37-....
3WL11 08-2@@37-....
3WL11 10-2@@37-....
3WL11 12-2@@37-....
3WL11 16-2@@37-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@37-....
3WL12 10-2@@37-....
3WL12 12-2@@37-....
3WL12 16-2@@37-....
3WL12 20-2@@37-....
3WL12 25-2@@37-....
3WL12 32-2@@37-....
3WL12 40-2@@37-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000
121.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@38-....
3WL11 08-2@@38-....
3WL11 10-2@@38-....
3WL11 12-2@@38-....
3WL11 16-2@@38-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@38-....
3WL12 10-2@@38-....
3WL12 12-2@@38-....
3WL12 16-2@@38-....
3WL12 20-2@@38-....
3WL12 25-2@@38-....
3WL12 32-2@@38-....
Order No. supplements

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000

Non-automatic air circuit breakers2)

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO
Additional price

1AA2

None

For footnotes see page 1/14.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/11

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
For Order No. supplements,
see page 1/23

S
Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@35-....
3WL11 08-3@@35-....
3WL11 10-3@@35-....
3WL11 12-3@@35-....
3WL11 16-3@@35-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

45.000
45.000
45.000
45.000
45.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@35-....
3WL12 10-3@@35-....
3WL12 12-3@@35-....
3WL12 16-3@@35-....
3WL12 20-3@@35-....
3WL12 25-3@@35-....
3WL12 32-3@@35-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

60.000
60.000
60.000
60.000
60.000
63.000
68.000

With guide frames, horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@36-....
3WL11 08-3@@36-....
3WL11 10-3@@36-....
3WL11 12-3@@36-....
3WL11 16-3@@36-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@36-....
3WL12 10-3@@36-....
3WL12 12-3@@36-....
3WL12 16-3@@36-....
3WL12 20-3@@36-....
3WL12 25-3@@36-....
3WL12 32-3@@36-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@37-....
3WL11 08-3@@37-....
3WL11 10-3@@37-....
3WL11 12-3@@37-....
3WL11 16-3@@37-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@37-....
3WL12 10-3@@37-....
3WL12 12-3@@37-....
3WL12 16-3@@37-....
3WL12 20-3@@37-....
3WL12 25-3@@37-....
3WL12 32-3@@37-....
3WL12 40-3@@37-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000
121.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@38-....
3WL11 08-3@@38-....
3WL11 10-3@@38-....
3WL11 12-3@@38-....
3WL11 16-3@@38-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

70.000
70.000
70.000
70.000
70.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@38-....
3WL12 10-3@@38-....
3WL12 12-3@@38-....
3WL12 16-3@@38-....
3WL12 20-3@@38-....
3WL12 25-3@@38-....
3WL12 32-3@@38-....
Order No. supplements

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000

Non-automatic air circuit breakers2)


Without electronic release

Add. price

AA

None

BB
CB
EB
FB
NB

DG
EG
FG
NG

Electronic releases
Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection
ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/14.
* You can order this quantity or a multiple thereof.

1/12

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@35-....
3WL12 10-4@@35-....
3WL12 12-4@@35-....
3WL12 16-4@@35-....
3WL12 20-4@@35-....
3WL12 25-4@@35-....
3WL12 32-4@@35-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

60.000
60.000
60.000
60.000
60.000
63.000
68.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@35-....
3WL13 50-4@@35-....
3WL13 63-4@@35-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

88.000
88.000
96.000

With guide frames, horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@36-....
3WL12 10-4@@36-....
3WL12 12-4@@36-....
3WL12 16-4@@36-....
3WL12 20-4@@36-....
3WL12 25-4@@36-....
3WL12 32-4@@36-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@36-....
3WL13 50-4@@36-....

1
1

1 unit
1 unit

103
103

148.000
148.000

With guide frames, vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@37-....
3WL12 10-4@@37-....
3WL12 12-4@@37-....
3WL12 16-4@@37-....
3WL12 20-4@@37-....
3WL12 25-4@@37-....
3WL12 32-4@@37-....
3WL12 40-4@@37-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000
121.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@37-....
3WL13 50-4@@37-....
3WL13 63-4@@37-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

148.000
148.000
166.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

91.000
91.000
91.000
91.000
91.000
102.000
113.000

1 unit

103

148.000

With guide frames, connecting flanges


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@38-....
3WL12 10-4@@38-....
3WL12 12-4@@38-....
3WL12 16-4@@38-....
3WL12 20-4@@38-....
3WL12 25-4@@38-....
3WL12 32-4@@38-....

III

4000

4000

100 B

3WL13 40-4@@38-....

Non-automatic air circuit breakers 2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI6)
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/14.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/13

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
3-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 150 kA at 500 V,


very high switching capacity C

kA

Order No.
Order No. supplements,
see page 1/23

C
Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

DT

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
III
III
III

4000
5000
6300

4000
5000
6300

150 B
150 B
150 B

3WL13 40-5@@35-....
3WL13 50-5@@35-....
3WL13 63-5@@35-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

88.000
88.000
96.000

150 B
150 B

3WL13 40-5@@36-....
3WL13 50-5@@36-....

1
1

1 unit
1 unit

103
103

148.000
148.000

150 B
150 B
150 B

3WL13 40-5@@37-....
3WL13 50-5@@37-....
3WL13 63-5@@37-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

148.000
148.000
166.000

With guide frames, horizontal main circuit connection


III
III

4000
5000

4000
5000

With guide frames, vertical main circuit connection


III
III
III

4000
5000
6300

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
Footnotes for pages 1/11 to 1/14:
1)

The rated current is determined by the rated current module. For the standard version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 1/24.

3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 1/34.

2)

For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 1/3.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 1/34.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT (alarm


and tripping), see page 1/34.

6)

ETU15B cannot be used with 3WL circuit breakers, size III.

* You can order this quantity or a multiple thereof.

1/14

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, fixed-mounted versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@42-....
3WL11 08-2@@42-....
3WL11 10-2@@42-....
3WL11 12-2@@42-....
3WL11 16-2@@42-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@42-....
3WL12 10-2@@42-....
3WL12 12-2@@42-....
3WL12 16-2@@42-....
3WL12 20-2@@42-....
3WL12 25-2@@42-....
3WL12 32-2@@42-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@41-....
3WL11 08-2@@41-....
3WL11 10-2@@41-....
3WL11 12-2@@41-....
3WL11 16-2@@41-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@41-....
3WL12 10-2@@41-....
3WL12 12-2@@41-....
3WL12 16-2@@41-....
3WL12 20-2@@41-....
3WL12 25-2@@41-....
3WL12 32-2@@41-....
3WL12 40-2@@41-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

75.000
75.000
75.000
75.000
67.000
71.000
77.000
103.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@43-....
3WL11 08-2@@43-....
3WL11 10-2@@43-....
3WL11 12-2@@43-....
3WL11 16-2@@43-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@43-....
3WL12 10-2@@43-....
3WL12 12-2@@43-....
3WL12 16-2@@43-....
3WL12 20-2@@43-....
3WL12 25-2@@43-....
3WL12 32-2@@43-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@44-....
3WL11 08-2@@44-....
3WL11 10-2@@44-....
3WL11 12-2@@44-....
3WL11 16-2@@44-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@44-....
3WL12 10-2@@44-....
3WL12 12-2@@44-....
3WL12 16-2@@44-....
3WL12 20-2@@44-....
3WL12 25-2@@44-....
3WL12 32-2@@44-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/18.
* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/15

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
Order No. supplements,
see page 1/23

S
Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@42-....
3WL11 08-3@@42-....
3WL11 10-3@@42-....
3WL11 12-3@@42-....
3WL11 16-3@@42-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@42-....
3WL12 10-3@@42-....
3WL12 12-3@@42-....
3WL12 16-3@@42-....
3WL12 20-3@@42-....
3WL12 25-3@@42-....
3WL12 32-3@@42-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@41-....
3WL11 08-3@@41-....
3WL11 10-3@@41-....
3WL11 12-3@@41-....
3WL11 16-3@@41-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@41-....
3WL12 10-3@@41-....
3WL12 12-3@@41-....
3WL12 16-3@@41-....
3WL12 20-3@@41-....
3WL12 25-3@@41-....
3WL12 32-3@@41-....
3WL12 40-3@@41-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000
103.000

Front main circuit connection, single hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@43-....
3WL11 08-3@@43-....
3WL11 10-3@@43-....
3WL11 12-3@@43-....
3WL11 16-3@@43-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@43-....
3WL12 10-3@@43-....
3WL12 12-3@@43-....
3WL12 16-3@@43-....
3WL12 20-3@@43-....
3WL12 25-3@@43-....
3WL12 32-3@@43-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Front main circuit connection, double hole


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@44-....
3WL11 08-3@@44-....
3WL11 10-3@@44-....
3WL11 12-3@@44-....
3WL11 16-3@@44-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

50.000
50.000
50.000
50.000
50.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@44-....
3WL12 10-3@@44-....
3WL12 12-3@@44-....
3WL12 16-3@@44-....
3WL12 20-3@@44-....
3WL12 25-3@@44-....
3WL12 32-3@@44-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/18.

* You can order this quantity or a multiple thereof.

1/16

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@42-....
3WL12 10-4@@42-....
3WL12 12-4@@42-....
3WL12 16-4@@42-....
3WL12 20-4@@42-....
3WL12 25-4@@42-....
3WL12 32-4@@42-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@42-....
3WL13 50-4@@42-....

1
1

1 unit
1 unit

103
103

99.000
99.000

Vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@41-....
3WL12 10-4@@41-....
3WL12 12-4@@41-....
3WL12 16-4@@41-....
3WL12 20-4@@41-....
3WL12 25-4@@41-....
3WL12 32-4@@41-....
3WL12 40-4@@41-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000
103.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@41-....
3WL13 50-4@@41-....
3WL13 63-4@@41-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

99.000
99.000
108.000

Front main circuit connection, single hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@43-....
3WL12 10-4@@43-....
3WL12 12-4@@43-....
3WL12 16-4@@43-....
3WL12 20-4@@43-....
3WL12 25-4@@43-....
3WL12 32-4@@43-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

III

4000

4000

100 B

3WL13 40-4@@43-....

1 unit

103

99.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

67.000
67.000
67.000
67.000
67.000
71.000
77.000

1 unit

103

99.000

Front main circuit connection, double hole


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@44-....
3WL12 10-4@@44-....
3WL12 12-4@@44-....
3WL12 16-4@@44-....
3WL12 20-4@@44-....
3WL12 25-4@@44-....
3WL12 32-4@@44-....

III

4000

4000

100 B

3WL13 40-4@@44-....

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI6)
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/18.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/17

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, fixed-mounted versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 130 kA at 500 V,


very high switching capacity C

kA

DT

Order No.
Order No. supplements,
see page 1/23

PU
(UNIT,
Basic SET, M)
price
per PU

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Horizontal main circuit connection


III
III

4000
5000

4000
5000

130 B
130 B

3WL13 40-5@@42-....
3WL13 50-5@@42-....

1
1

1 unit
1 unit

103
103

99.000
99.000

4000
5000
6300

130 B
130 B
130 B

3WL13 40-5@@41-....
3WL13 50-5@@41-....
3WL13 63-5@@41-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

99.000
99.000
108.000

Vertical main circuit connection


III
III
III

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
Footnotes for pages 1/15 to 1/18:
1)

The rated current is determined by the rated current module. For the standard version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 1/24.

2)

For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 1/3.

3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 1/34. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 1/26.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 1/34.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT (alarm


and tripping), see page 1/34.

6)

ETU15B cannot be used with 3WL circuit breakers, size III.

* You can order this quantity or a multiple thereof.

1/18

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, withdrawable versions

Selection and ordering data


Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 55/66 kA at 500 V,


ECO switching capacity N

kA

DT

Order No.
Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@45-....
3WL11 08-2@@45-....
3WL11 10-2@@45-....
3WL11 12-2@@45-....
3WL11 16-2@@45-....

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@45-....
3WL12 10-2@@45-....
3WL12 12-2@@45-....
3WL12 16-2@@45-....
3WL12 20-2@@45-....
3WL12 25-2@@45-....
3WL12 32-2@@45-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

54.000
54.000
54.000
54.000
54.000

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

75.000
75.000
75.000
75.000
72.000
76.000
82.000

With guide frames, horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@46-....
3WL11 08-2@@46-....
3WL11 10-2@@46-....
3WL11 12-2@@46-....
3WL11 16-2@@46-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@46-....
3WL12 10-2@@46-....
3WL12 12-2@@46-....
3WL12 16-2@@46-....
3WL12 20-2@@46-....
3WL12 25-2@@46-....
3WL12 32-2@@46-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@47-....
3WL11 08-2@@47-....
3WL11 10-2@@47-....
3WL11 12-2@@47-....
3WL11 16-2@@47-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

66
66
66
66
66
66
66
66

B
B
B
B
B
B
B
B

3WL12 08-2@@47-....
3WL12 10-2@@47-....
3WL12 12-2@@47-....
3WL12 16-2@@47-....
3WL12 20-2@@47-....
3WL12 25-2@@47-....
3WL12 32-2@@47-....
3WL12 40-2@@47-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

55
55
55
55
55

B
B
B
B
B

3WL11 06-2@@48-....
3WL11 08-2@@48-....
3WL11 10-2@@48-....
3WL11 12-2@@48-....
3WL11 16-2@@48-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

66
66
66
66
66
66
66

B
B
B
B
B
B
B

3WL12 08-2@@48-....
3WL12 10-2@@48-....
3WL12 12-2@@48-....
3WL12 16-2@@48-....
3WL12 20-2@@48-....
3WL12 25-2@@48-....
3WL12 32-2@@48-....
Order No. supplements

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

Non-automatic air circuit breakers2)

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection

BB
CB
EB
FB
NB

ETU27B: Protection functions LSING4)


ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO
Additional price

1AA2

None

For footnotes see page 1/22.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/19

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


In
current
In max.

Icu up to 66/80 kA at 500 V,


standard switching capacity S

kA

DT

Order No.
Order No. supplements,
see page 1/23

S
Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@45-....
3WL11 08-3@@45-....
3WL11 10-3@@45-....
3WL11 12-3@@45-....
3WL11 16-3@@45-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

54.000
54.000
54.000
54.000
54.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@45-....
3WL12 10-3@@45-....
3WL12 12-3@@45-....
3WL12 16-3@@45-....
3WL12 20-3@@45-....
3WL12 25-3@@45-....
3WL12 32-3@@45-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

72.000
72.000
72.000
72.000
72.000
76.000
82.000

With guide frames, horizontal main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@46-....
3WL11 08-3@@46-....
3WL11 10-3@@46-....
3WL11 12-3@@46-....
3WL11 16-3@@46-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@46-....
3WL12 10-3@@46-....
3WL12 12-3@@46-....
3WL12 16-3@@46-....
3WL12 20-3@@46-....
3WL12 25-3@@46-....
3WL12 32-3@@46-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

With guide frames, vertical main circuit connection


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@47-....
3WL11 08-3@@47-....
3WL11 10-3@@47-....
3WL11 12-3@@47-....
3WL11 16-3@@47-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

80
80
80
80
80
80
80
80

B
B
B
B
B
B
B
B

3WL12 08-3@@47-....
3WL12 10-3@@47-....
3WL12 12-3@@47-....
3WL12 16-3@@47-....
3WL12 20-3@@47-....
3WL12 25-3@@47-....
3WL12 32-3@@47-....
3WL12 40-3@@47-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000

With guide frames, connecting flanges


I
I
I
I
I

630
800
1000
1250
1600

630
800
1000
1250
1600

66
66
66
66
66

B
B
B
B
B

3WL11 06-3@@48-....
3WL11 08-3@@48-....
3WL11 10-3@@48-....
3WL11 12-3@@48-....
3WL11 16-3@@48-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

84.000
84.000
84.000
84.000
84.000

II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

80
80
80
80
80
80
80

B
B
B
B
B
B
B

3WL12 08-3@@48-....
3WL12 10-3@@48-....
3WL12 12-3@@48-....
3WL12 16-3@@48-....
3WL12 20-3@@48-....
3WL12 25-3@@48-....
3WL12 32-3@@48-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

Non-automatic air circuit breakers2)


Without electronic release

Order No. supplements

Add. price

AA

None

BB
CB
EB
FB
NB

DG
EG
FG
NG

Electronic releases
Versions without ground-fault protection
ETU15B: Protection functions LI
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display
Versions with ground-fault protection
ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/22.
* You can order this quantity or a multiple thereof.

1/20

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 100 kA at 500 V,


high switching capacity H

kA

DT

Order No.
Order No. supplements,
see page 1/23

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@45-....
3WL12 10-4@@45-....
3WL12 12-4@@45-....
3WL12 16-4@@45-....
3WL12 20-4@@45-....
3WL12 25-4@@45-....
3WL12 32-4@@45-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

72.000
72.000
72.000
72.000
72.000
76.000
82.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@45-....
3WL13 50-4@@45-....
3WL13 63-4@@45-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

106.000
106.000
108.000

With guide frames, horizontal main circuit connection


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@46-....
3WL12 10-4@@46-....
3WL12 12-4@@46-....
3WL12 16-4@@46-....
3WL12 20-4@@46-....
3WL12 25-4@@46-....
3WL12 32-4@@46-....

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

III
III

4000
5000

4000
5000

100 B
100 B

3WL13 40-4@@46-....
3WL13 50-4@@46-....

1
1

1 unit
1 unit

103
103

190.000
190.000

With guide frames, vertical main circuit connection


II
II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200
4000

800
1000
1250
1600
2000
2500
3200
4000

100
100
100
100
100
100
100
100

B
B
B
B
B
B
B
B

3WL12 08-4@@47-....
3WL12 10-4@@47-....
3WL12 12-4@@47-....
3WL12 16-4@@47-....
3WL12 20-4@@47-....
3WL12 25-4@@47-....
3WL12 32-4@@47-....
3WL12 40-4@@47-....

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000
146.000

III
III
III

4000
5000
6300

4000
5000
6300

100 B
100 B
100 B

3WL13 40-4@@47-....
3WL13 50-4@@47-....
3WL13 63-4@@47-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

190.000
190.000
227.000

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103

109.000
109.000
109.000
109.000
109.000
123.000
136.000

1 unit

103

190.000

With guide frames, connecting flanges


II
II
II
II
II
II
II

800
1000
1250
1600
2000
2500
3200

800
1000
1250
1600
2000
2500
3200

100
100
100
100
100
100
100

B
B
B
B
B
B
B

3WL12 08-4@@48-....
3WL12 10-4@@48-....
3WL12 12-4@@48-....
3WL12 16-4@@48-....
3WL12 20-4@@48-....
3WL12 25-4@@48-....
3WL12 32-4@@48-....

III

4000

4000

100 B

3WL13 40-4@@48-....

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU15B: Protection functions LI6)
ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

BB
CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
For footnotes see page 1/22.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/21

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
4-pole, withdrawable versions
Size

Max. rated circuit breaker Rated current1)


current
In
In max.

Icu up to 130 kA at 500 V,


very high switching capacity C

kA

DT

Order No.
Order No. supplements,
see page 1/23

PU
(UNIT,
Basic SET, M)
price
per PU

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/30 to 1/33)
III
III
III

4000
5000
6300

4000
5000
6300

130 B
130 B
130 B

3WL13 40-5@@45-....
3WL13 50-5@@45-....
3WL13 63-5@@45-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

115.000
106.000
108.000

130 B
130 B

3WL13 40-5@@46-....
3WL13 50-5@@46-....

1
1

1 unit
1 unit

103
103

190.000
190.000

130 B
130 B
130 B

3WL13 40-5@@47-....
3WL13 50-5@@47-....
3WL13 63-5@@47-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

190.000
190.000
227.000

With guide frames, horizontal main circuit connection


III
III

4000
5000

4000
5000

With guide frames, vertical main circuit connection


III
III
III

4000
5000
6300

4000
5000
6300

Non-automatic air circuit breakers2)

Order No. supplements

Add. price

AA

None

Versions without ground-fault protection


ETU25B: Protection functions LSI
ETU45B: Protection functions LSIN3)
ETU45B: Protection functions LSIN3) with 4-line display
ETU76B: Protection functions LSIN3) with pixel graphics display

CB
EB
FB
NB

Versions with ground-fault protection


ETU27B: Protection functions LSING4)
ETU45B: Protection functions LSING3)5)
ETU45B: Protection functions LSING3)5) with 4-line display
ETU76B: Protection functions LSING3)5) with pixel graphics display

DG
EG
FG
NG

Without electronic release

Electronic releases

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Without 1st and 2nd auxiliary releases; auxiliary switch 2 NC + 2 NO

1AA2

None

Additional price
Footnotes for pages 1/19 to 1/22:
1)

The rated current is determined by the rated current module. For the standard version, the supplied module is equal to the maximum rated current.
If a lower rated current is required, adaptation by order code on page 1/24.

2)

For permissible rated short-time current Icc and rated short-circuit making
capacity Icm for non-automatic air circuit breakers see page 1/3.

3)

Current transformers for protection of the N conductor and current transformers for detection of the ground-fault current in the grounded neutral
point of the transformer are to be ordered separately, see page 1/34. The
internal current transformers for N conductors can be ordered by adding
the supplement "Z" and the order code "F23", see page 1/26.

4)

Current transformers for protection of the N conductor are to be ordered


separately, see page 1/34.

5)

ETU45B to ETU76B with ground-fault protection module GFM AT (alarm


and tripping), see page 1/34.

6)

ETU15B cannot be used with 3WL circuit breakers, size III.

* You can order this quantity or a multiple thereof.

1/22

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Options

Selection and ordering data


Order No. supplement

Additional
price

3WL 1 . . . - . . . . . -7 7 7 7

Operating mechanism
Manual operating mechanism with mechanical closing

None

2
3

4
5
6

Manual operating mechanism with mechanical


and electrical closing,
closing solenoid suitable for uninterrupted duty, 100 % duty ratio
Closing solenoid
50/60 Hz V AC

V DC

110
230

110 ... 125


220

Manual/motorized operating mechanism with mechanical


and electrical closing,
closing solenoid suitable for uninterrupted duty, 100 % duty ratio
Motor

Closing solenoid

50/60 Hz V AC

V DC

50/60 Hz V AC

V DC

208 ... 240


110 ... 127
--

220 ... 250


110 ... 125
24

230
110
--

220
110 ... 125
24

To order different voltages for motorized operating mechanism and closing


solenoid or closing solenoid for synchronization purposes:
"1" at the 13th digit of the Order No. and order codes, see page 1/25.

1. Auxiliary releases
Without 1st auxiliary release

None

B
C
D
E
F
G

Shunt release suitable for uninterrupted duty, 100 % duty ratio


Operating range 0.85 ... 1.1 Us
Us 50/60 Hz V AC Us V DC
----110
230

24
30
48
60
110 ... 125
220

2. Auxiliary releases
Without 2nd auxiliary release

None

B
C
D
E
F
G

J
K
L
U
M
N
P

Q
R
S
T

Shunt release suitable for uninterrupted duty, 100 % duty ratio


Operating range 0.85 ... 1.1 Us
Us 50/60 Hz V AC Us V DC
-24
-30
-48
-60
110
110 ... 125
230
220
Undervoltage release, instantaneous ( 80 ms),
short-delay ( 200 ms)
Operating range 0.85 ... 1.1 Us
Us 50/60 Hz V AC Us V DC
----110 ... 127
208 ... 240
380 ... 415

24
30
48
60
110 ... 125
220 ... 250
--

Undervoltage release, can be delayed between 0.2 s and 3.2 s


Operating range 0.85 ... 1.1 Us
Us 50/60 Hz V AC Us V DC
-110 ... 127
208 ... 240
380 ... 415

48
110 ... 125
220 ... 250
--

Auxiliary switches
1. auxiliary switch block
2 NO + 2 NC

None

1. + 2. auxiliary switch block


4 NO + 4 NC
6 NO + 2 NC
5 NO + 3 NC

4
7
8

Additional price

Siemens LV 10.1 2011

1/23

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


1234 5 6 7

8 9 10 11 12

Additional price
13 14 15 16

3WL . . . . - . . . . . - . . . . - Z
and additional order code(s)
@@@+ . . . + . . .
Code for
"Further versions"

-Z

Operating manuals
Printed version
In scope of supply of circuit breaker) French/Italian

A 1 1

In scope of supply of circuit breaker) Spanish/Portuguese

A 1 2

Rated voltage 1000 V AC/DC


Only for circuit breakers with high switching capacity H
(8th digit of the Order No. is a "4")
Cannot be combined with "Rated voltage 1150 V AC order code "A15".

Add.
price
3-pole

Add.
price
4-pole

Size II1)

Up to 2000 A
2500 A
3200 A

A 0 5
A 0 5
A 0 5

Size III1)2)

4000 A
5000 A
6300 A

A 0 5
A 0 5
A 0 5

A
A
A
A

5
5
5
5

A 0 8
A 0 8
A 0 8

Rated voltage 1150 V AC


Only for circuit breakers with high switching capacity H
(8th digit of the Order No. is a "4")
Cannot be combined with "Rated voltage 1000 V AC order code "A05".
Size II

Up to 2000 A
2500 A
3200 A
4000 A
For size III select a circuit breaker with very high switching capacity C,
which can be used as standard up to 1150 V AC.

1
1
1
1

Tinned version of the customer's connections


on the guide frame3)4)
Only for circuit breakers in withdrawable version with horizontal connection or
flange connection. The normal delivery time increases to 15 work days.
Size I
Size II
Size III

Special packaging (moisture protection)

Additional price

Special packaging for extended technical requirements


Cardboard packaging with water-repellent coating on corrugated cardboard A 6 1
(moisture protection)

Rated current modules / Rating plugs

Additional price

Rated
current In
A
Only one module is possible per For size I, II
circuit breaker (not in conjunction
with electronic release ETU15B).
As standard the overcurrent
releases are equipped with a
rated current module which is
equal to the maximum rated circuit breaker current (In max). The
rated current of the selected
rated current module must be
For size I, II, III
smaller than In max.
For size II, III

For size III

250

B 0 2

None

315

B 0 3

None

400

B 0 4

None

500

B 0 5

None

630

B 0 6

None

800

B 0 8

None

1000

B 1 0

None

1250

B 1 2

None

1600

B 1 6

None

2000

B 2 0

None

2500

B 2 5

None

3200

B 3 2

None

4000

B 4 0

None

5000

B 5 0

None

6300

B 6 3

None

Additional price
1)

If ordering withdrawable circuit breaker and guide frame separately,


specify order code "A05" for withdrawable circuit breaker and guide frame.

2)

Not necessary for circuit breakers with very high switching capacity C as
these circuit breakers can be used as standard up to 1150 V AC.

3)

Front connections are tinned as standard.

4)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

1/24

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. with "Z"


1234 5 6 7

8 9 10 11 12

Additional price
13 14 15 16

3WL . . . . - . . . . . - . . . . - Z
and additional order code(s)
@@@+. . . + . . .
Code for
"Further versions"

-Z

Indication/operator control elements, door sealing frames


5-digit mechanical operating cycles counter1)

C 0 1

Electrical ON button in the operator


panel2)
Possible only for circuit breakers
with closing solenoid.

Button with sealing cap

C 1 1

Key operation with lock CES

C 1 2

Storage status signaling switch 2)


(S21)

1 NO contact

C 2 0

Ready-to-close signaling switch (S20) 1 NO contact

C 2 2

For the first auxiliary release (S22)


C 2 6
For the second auxiliary release (S23) C 2 7

Signaling switches2)

Motor shutdown switch in the operator panel3)

S 2 5

S 2 4

T 4 0

Automatic reset of the reclosing lockout

K 0 1

Tripped signaling switch2)4)

K 0 7

K
K
K
K

1
1
1
1

0
1
2
3

M
M
M
M

0
0
0
0

1
3
5
6

24
30
48

M2 1
M2 2
M2 3

60
110
220

M2 4
M2 5
M2 6

M
M
M
M

3
3
3
3

1
3
5
6

M
M
M
M

4
4
4
4

1
3
5
6

EMERGENCY-STOP pushbuttons

Mushroom pushbutton instead of


the mechanical OFF pushbutton

Door sealing frames

Reclosing lockout and remote resets


1 CO

Remote reset solenoid for displays and reset buttons


including automatic reset of the reclosing lockout
50/60 Hz V AC

V DC

--120
208 ... 250

24
48
125
208 ... 250

Motorized operating mechanisms and closing/opening solenoids


Motorized operating mechanisms
Only possible if the 13th digit of the Order No. = "1"
Motor
50/60 Hz V AC

V DC

--110 ... 127


208 ... 240

24 ... 30
48 ... 60
110 ... 125
220 ... 250

Closing solenoid suitable for uninterrupted duty, 100 % duty ratio


Only possible if the 13th digit of the Order No. = "1"
Activation solenoids
50/60 Hz V AC

V DC

----110
230

Closing solenoids5) unsuitable for uninterrupted duty, 5 % duty ratio,


synchronizable
Only possible if the 13th digit of the Order No. = "1"
Activation solenoids
50/60 Hz V AC

V DC

--110 ... 127


208 ... 240

24
48
110 ... 125
220 ... 250

Opening solenoids (shunt release)6)7)


Not suitable for uninterrupted duty, 5% duty ratio, synchronizable
Activation solenoids
50/60 Hz V AC

V DC

--110 ... 127


208 ... 240

24
48
110 ... 125
220 ... 250

Additional price

4)

1)

5)

Only possible with motorized operating mechanism.


2)
Not possible with communications interface option, order code "F02" or "F12".
3) Only for circuit breakers with motorized operating mechanism, not possible
with order codes "C11", "C12".

Not available for non-automatic air circuit breakers.


Overexcited, i.e. opening time 50 ms (standard > 80 ms).
6) Only possible if the 14th position of the Order No. for the circuit breaker is
"A", i.e. "without 1st auxiliary release".
7)
Overexcited, i.e. opening time 50 ms (standard > 80 ms).

Siemens LV 10.1 2011

1/25

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. mit "-Z"


1234 5 6 7

8 9 10 11 12

Additional
price

13 14 15 16

3WL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@ + . . . + . . .
Code for
"Further versions"

Order code
for withdrawable
version

@@@

@@@

Fixed-mounted circuit breakers

S 5 5

-- -- --

For withdrawable circuit breakers


with guide frame

--

R 5 5

For guide frames

--

R 5 6

For withdrawable circuit breakers

--

R 5 7

3-pole
Size I
Size II
Size III

----

R 1 0
R 1 0
R 1 0

4-pole
Size I
Size II
Size III

----

R 1 0
R 1 0
R 1 0

3-pole
Size I
Size II
Size III

----

R 2 1
R 2 1
R 2 1

4-pole
Size I
Size II
Size III

----

R 2 1
R 2 1
R 2 1

Interlocks, covers, position signaling switches


Mutual mechanical
interlockings
(interlocking module
with Bowden wire 2 m)

Arc chute covers


Not available for
- 1000 V version
(order code "A05")
- DC version
- 4000 A size II
- 1150 V version
(order code "A15")
- 150-kA version, size III
Shutters
2-part
lockable
with padlocks 1)

Position signaling switches


for guide frames

-Z

Order code
for fixedmounted
version

Connected Test
position
position

Disconnected
position

1 CO

1 CO

1 CO

--

R 1 5

3 CO

2 CO

1 CO

--

R 1 6

Add "Z" to the complete Order No. and


indicate the appropriate order code(s).

Order No. with "Z"


1234 5 6 7

8 9 10 11 12

Additional
price

13 14 15 16

3WL . . . . - . . . . . - . . . . - Z
and additional order code(s)
@@@

+. . . + . . .
Code for
"Further versions"

-Z

Communication and measurement functions


Breaker status sensor (BSS)

F 0 1

PROFIBUS communications interface2) Including COM15 and breaker


status sensor (BSS)

F 0 2

MODBUS communications interface2)

F 1 2

F 0 5

F 2 3

F 2 3

F 2 3

Common-mode interference
F 3 1
suppressor filters (e.g. in IT networks, caused by frequency converters)

Including COM16 and breaker


status sensor (BSS)

Measurement function Plus (without PROFIBUS/MODBUS


communications interface)3)

Overload and short-circuit protection for neutral conductors


Internal current transformers for
Size I
N conductors
Size II
Only possible with 4-pole circuit breakers
Size III
with ETU27B to ETU76B

EMC filters
EMC filters

Insertion loss (asymmetric) in the


range 40 kHz to 10 MHz >40 dB.
Additional price
1)

Padlocks not included in scope of supply.

2)

If ordering withdrawable circuit breaker and guide frame separately, specify order code "F02" or "F12" for withdrawable circuit breaker only.

1/26

Siemens LV 10.1 2011

3)

Additional voltage transformers are required for connection of the measurement function Plus, see page 1/43.

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Options
Add "Z" to the complete Order No.
and indicate the appropriate order code(s).

Order No. mit "-Z"


1234 5 6 7

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@ + . . . + . . .
Code for
"Further versions"
Order code
for fixedmounted
version

Order code
for withdrawable
version

@@@

Locking devices
Locking devices against
unauthorized closing,
in the operator panels
The disconnector unit fulfills the
requirements for main circuit
breakers acc. to EN 60204-1

-Z

Add. price
for fixedmounted
version

Add. price
for withdrawable version

@@@

Made by CES

S 0 1

S 0 1

Made by IKON

S 0 3

S 0 3

Assembly kit FORTRESS or Castell1)

S 0 5

S 0 5

Assembly kit for padlocks2)

S 0 7

S 0 7

Made by Ronis

S 0 8

S 0 8

Made by Profalux

S 0 9

S 0 9

EMERGENCY-STOP pushbuttons Mushroom pushbutton instead of


the mechanical OFF pushbutton

S 2 4

S 2 4

Locking devices against


Made by CES
unauthorized closing,
Made by Ronis
for withdrawable circuit breakers
Made by Profalux
The disconnector unit fulfils the
requirements for main circuit
breakers acc. to EN 60204-1,
consisting of a lock in the cabinet
door, active in the connected position, function is retained when circuit
breaker is replaced.

--

R 6 1

--

R 6 8

--

R 6 0

Locking devices for operating


mechanism handles
with padlock2)

S 3 3

S 3 3

Locking devices to prevent move- Made by CES


ment of the withdrawable circuit
Made by Profalux
breakers
Made by Ronis
Safety lock for mounting on the
circuit breaker

--

S 7 1

--

S 7 5

--

S 7 6

--

R 8 1

--

R 8 5

--

R 8 6

R 3 0

R 5 0

P 6 1

Locking mechanisms
Locking mechanisms to prevent
Made by CES
movement of the withdrawable
Made by Profalux
circuit breaker in disconnected
Made by Ronis
positions,
consisting of Bowden wire and lock
in the cabinet door
Not possible in combination with
order code "R30" or "R50".
Locking devices
Not possible in combination with
order code "R81", "R85" or "R86".

To prevent opening of the cabinet door in: S 3 0


ON position (fixed-mounted version)/
in connected position (withdrawable
version)
To prevent movement
with the cabinet door open

--

Connection methods for auxiliary conductors


Connections for screwless
terminals (tension spring)

N 6 1

Additional price
1)

Locks must be ordered from the manufacturer.

2)

Padlock not included in the scope of supply.

Siemens LV 10.1 2011

1/27

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Options
Add "Z" to the complete Order No. and
indicate the appropriate order code(s).

Order No. mit "-Z"


1234 5 6 7

8 9 10 11 12

13 14 15 16

3WL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@

+. . . + . . .
Code for
"Further versions"

For withdrawable circuit breakers with guide frames


or for guide frames1)
To select this connection method the 12th
digit of the Order No. for the
circuit breaker must be a "6"

-Z

Additional
price
3-pole

Additional
price
4-pole

Connection methods for main connections


Top and bottom:
accessible from front,
single hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

0
0
0
0
0

0
0
0
0
0

Top and bottom:


accessible from front,
double hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

0
0
0
0
0

1
1
1
1
1

Top:
horizontal,
double hole
Bottom:
accessible from front,
single hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

0
0
0
0
0

7
7
7
7
7

Top:
vertical
Bottom:
horizontal

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

P
P
P
P
P
P

1
1
1
1
1
1

8
8
8
8
8
8

Top:
connecting flange
Bottom:
horizontal

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

P
P
P
P
P

1
1
1
1
1

9
9
9
9
9

Top:
horizontal
Bottom:
vertical

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

P
P
P
P
P
P

2
2
2
2
2
2

3
3
3
3
3
3

Additional
price
3-pole

Additional
price
4-pole

For fixed-mounted circuit breakers


To select this connection method the 12th
digit of the Order No. for the
circuit breaker must be a "2"
Connection methods for main connections
Top:
horizontal
Bottom:
accessible from front,
single hole

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A

N
N
N
N
N

1
1
1
1
1

1
1
1
1
1

Top:
vertical
Bottom:
horizontal

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

N
N
N
N
N
N

2
2
2
2
2
2

0
0
0
0
0
0

Top:
horizontal
Bottom:
vertical

Size I, up to 1600 A
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Size III, up to 4000 A
Size III, up to 5000 A

N
N
N
N
N
N

2
2
2
2
2
2

4
4
4
4
4
4

Additional price
1)

Only horizontal connection and vertical connection are available for circuit
breakers with very high switching capacity C.

1/28

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts

Overview
Determination of the number of auxiliary supply connectors required

NSE0_01104

This selection is only required if the guide frame is ordered under a


separate Order No.
X7

X6

X5

X8

The required number of auxiliary supply connectors


depends on:
Operating mechanism type
Electronic release with/without current transformer
Type and number of auxiliary releases
Number of auxiliary switches
COM15/COM16 communication interface
Number of
auxiliary supply
connectors

Terminal

First auxiliary supply connector X6 always required.

X6

b
b1
b2
b3

Operating mechanisms
Manual operating mechanism with stored-energy feature with mechanical closing
Manual operating mechanism with stored-energy feature with mechanical and electrical closing
Manual/motorized operating mechanism with stored-energy feature with mechanical and electrical closing

0
0
+1

X6
X5

c
c1
c2

Electronic releases
Electronic releases ETU15B, ETU25B, ETU27B
Electronic releases ETU45B, ETU76B (internal CubicleBUS)

0
+1

X8

c3
c4

Connections for external current transformers for overload protection in the N conductor and ground-fault protection
Current transformer installed in the N conductor (required with 3-pole circuit breakers if c2 is not selected)
Current transformer in the neutral point of the transformer (required if c2 or c3 is not selected)

+1
+1

X8
X8

d
d1
d2

Auxiliary releases
With/without 1st auxiliary release (shunt release F1)
2nd auxiliary release (shunt release F2, undervoltage release F3, delayable undervoltage release F4)

0
+1

X6
X5

e
e1
e2

Auxiliary switch blocks


1st auxiliary switch block 2 NO + 2 NC
1st and 2nd auxiliary switch block 4 NO + 4 NC or 6 NO + 2 NC or 5 NO + 3 NC (required if b3 or d2 is not selected)

0
+1

X6
X5

f
f1
f2

Communication modules
Without communication module COM15/COM16
With communication module COM15/COM16
occupies the entire terminal strip X7, making the following options no longer possible:
Tripped signal switch S24
Stored-energy status indication S21
Electrical ON button S10
Signaling switch on first and second auxiliary release S22 + S23

0
+1

X7

g
g1
g2
g3
g4
g5
g6
g7
g8

Optional signals/accessories
Tripped signaling switch S24 (only when f2 not selected)
Stored energy status signaling switch S21 (only when f2 not selected, required if g1 not selected)
Electric ON button S10 (only when f2 not selected, required if g1 or g2 not selected)
Signaling switch at first auxiliary release S22 (only when f2 not selected, required if g1, g2 or g3 not selected)
Signaling switch at second auxiliary release S23 (only when f2 not selected, required if g1, g2, g3 or g4 not selected)
Switch on readiness signal switch S20
Motor shutdown switch S12 (only if motorized operating mechanism selected)
Remote reset solenoid F7 (required if c2 not selected)

+1
+1
+1
+1
+1
0
0
+1

X7
X7
X7
X7
X7
X6
X5
X8

Total number of auxiliary supply connectors

(max. 4)

For ordering the auxiliary supply connectors see under "Accessories and Spare Parts, Guide Frames for AC Circuit Breakers/
Non-Automatic Air Circuit Breakers", pages 1/30 to 1/33 and under "Accessories and Spare Parts, Auxiliary Conductor Connections,
Auxiliary Supply Connectors", page 1/39.

Siemens LV 10.1 2011

1/29

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts

Selection and ordering data


Guide frames for AC circuit breakers/non-automatic air circuit breakers
Size

Max. rated circuit


breaker current
In max.

Switching DT
capacity
Icu

kA

Guide frames for 3-pole circuit breakers/


non-automatic air circuit breakers
Order No.
(Order No. supplements
required acc. to table below)

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Front main circuit connection, single hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

... 66
... 66
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1AA@@-@@A1
3WL9 211-2AA@@-@@A1
3WL9 212-3AA@@-@@A1
3WL9 212-4AA@@-@@A1
3WL9 212-5AA@@-@@A1
3WL9 213-6AA@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000

... 66
... 66
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1AB@@-@@A1
3WL9 211-2AB@@-@@A1
3WL9 212-3AB@@-@@A1
3WL9 212-4AB@@-@@A1
3WL9 212-5AB@@-@@A1
3WL9 213-6AB@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000

... 66
... 66
... 100
... 100
... 100
... 100
... 100
... 150
... 150

B
B
B
B
B
B
B
B
B

3WL9 211-1AC@@-@@A1
3WL9 211-2AC@@-@@A1
3WL9 212-3AC@@-@@A1
3WL9 212-4AC@@-@@A1
3WL9 212-5AC@@-@@A1
3WL9 213-6AC@@-@@A1
3WL9 213-7AC@@-@@A1
3WL9 213-6AC@@-@@C1
3WL9 213-7AC@@-@@C1

1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000
60.000
63.000
63.000

Front main circuit connection, double hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Horizontal main circuit connection


I
I
II
II
II
III
III
III
III

1000
1600
2000
2500
3200
4000
5000
4000
5000

Number of auxiliary supply connectors


Without
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 1/29

Order No. supplements


0
1
2
3
4

Add. price
None

Type of auxiliary circuit connections


Without
With screw connection (SIGUT, standard)
With screwless connection method (tension spring)

None

0
1
2

Position signaling switches


Without
Option 1

Connected position 1 CO,


test position 1 CO,
disconnected position 1 CO
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO

Option 2

0
1

None

Shutters
Without
With shutter,
2-part,
lockable

Add "Z" to the complete Order No.


and indicate the appropriate order code(s).

None

A
B

Size I
Size II
Size III

Order No. with "Z"


and additional order code

1234 5 6 7

8 9 10 11 12 13 14 15 16

3WL9 2 1 . . . . . . . . . . Z
@@@

Additional
price

Rated voltage 1000 V AC


Size II, except 4000 A (switching capacity H)
A05
Size III, not necessary with circuit breakers with very high switching capacity A 0 5

Size II, except 4000 A (switching capacity H)

A15

A08
A08
A08

Rated voltage 1150 V AC


Tinned version of the customer's connections on the guide frame1)2)
Only for guide frames with horizontal connection or flange connection
Size I
Size II
Size III

For main circuit connection vertical and main circuit connecting flange see the following page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code, see pages 1/24 to 1/28.
Additional price
1)

Front connections are tinned as standard.

2)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

* You can order this quantity or a multiple thereof.

1/30

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Size

Max. rated circuit breaker


current
In max.

Switching DT
capacity
Icu

kA

Guide frames for 3-pole circuit breakers/


non-automatic air circuit breakers
Order No.
(Order No. supplements
required acc. to table below)

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Vertical main circuit connection


I
I
II
II
II
II
III
III
III
III
III
III

1000
1600
2000
2500
3200
4000
4000
5000
6300
4000
5000
6300

... 66
... 66
... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 150
... 150
... 150

B
B
B
B
B
B
B
B
B
B
B
B

3WL9 211-1AD@@-@@A1
3WL9 211-2AD@@-@@A1
3WL9 212-3AD@@-@@A1
3WL9 212-4AD@@-@@A1
3WL9 212-5AD@@-@@A1
3WL9 212-6AD@@-@@A1
3WL9 213-6AD@@-@@A1
3WL9 213-7AD@@-@@A1
3WL9 213-8AD@@-@@A1
3WL9 213-6AD@@-@@C1
3WL9 213-7AD@@-@@C1
3WL9 213-8AD@@-@@C1

1
1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
52.000
60.000
60.000
70.000
63.000
63.000
74.000

... 66
... 66
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1AE@@-@@A1
3WL9 211-2AE@@-@@A1
3WL9 212-3AE@@-@@A1
3WL9 212-4AE@@-@@A1
3WL9 212-5AE@@-@@A1
3WL9 213-6AE@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

25.000
25.000
31.000
39.000
45.000
60.000

Main circuit connection connecting flanges


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Number of auxiliary supply connectors


Without
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 1/29

Order No. supplements


0
1
2
3
4

Add. price
None

Type of auxiliary circuit connections


Without
With screw connection (SIGUT, standard)
With screwless connection method (tension spring)

None

0
1
2

Position signaling switches


Without
Option 1
Option 2

Connected position 1 CO,


test position 1 CO,
disconnected position 1 CO
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO

0
1

None

Shutters
Without
With shutter,
2-part,
lockable

Add "Z" to the complete Order No.


and indicate the appropriate order code(s).

None

A
B

Size I
Size II
Size III

Order No. with "Z"


and additional order code

1234 5 6 7

8 9 10 11 12 13 14 15 16

3WL9 2 1 . . . . . . . . . . Z
@@@

Additional
price

Rated voltage 1000 V AC


Size II, except 4000 A (switching capacity H)
A05
Size III, not necessary with circuit breakers with very high switching capacity A 0 5

Size II, except 4000 A (switching capacity H)

A15

A08
A08
A08

Rated voltage 1150 V AC


Tinned version of the customer's connections on the guide frame1)2)
Only for guide frames with horizontal connection or flange connection
Size I
Size II
Size III

For main circuit connection front, single hole, main circuit connection front, double hole, and main circuit connection horizontal see
the previous page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code, see pages 1/24 to 1/28.
Additional price
1)

Front connections are tinned as standard.

2)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/31

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Size

Max. rated circuit breaker


current
In max.

Switching DT
capacity
Icu

kA

Guide frames for 4-pole circuit breakers/


non-automatic air circuit breakers
Order No.
(Order No. supplements
required acc. to table below)

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Front main circuit connection, single hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

... 66
... 66
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1BA@@-@@A1
3WL9 211-2BA@@-@@A1
3WL9 212-3BA@@-@@A1
3WL9 212-4BA@@-@@A1
3WL9 212-5BA@@-@@A1
3WL9 213-6BA@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000

... 66
... 66
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1BB@@-@@A1
3WL9 211-2BB@@-@@A1
3WL9 212-3BB@@-@@A1
3WL9 212-4BB@@-@@A1
3WL9 212-5BB@@-@@A1
3WL9 213-6BB@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000

... 66
... 66
... 100
... 100
... 100
... 100
... 100
... 130
... 130

B
B
B
B
B
B
B
B
B

3WL9 211-1BC@@-@@A1
3WL9 211-2BC@@-@@A1
3WL9 212-3BC@@-@@A1
3WL9 212-4BC@@-@@A1
3WL9 212-5BC@@-@@A1
3WL9 213-6BC@@-@@A1
3WL9 213-7BC@@-@@A1
3WL9 213-6BC@@-@@C1
3WL9 213-7BC@@-@@C1

1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000
84.000
87.000
87.000

Front main circuit connection, double hole


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Horizontal main circuit connection


I
I
II
II
II
III
III
III
III

1000
1600
2000
2500
3200
4000
5000
4000
5000

Number of auxiliary supply connectors


Without
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 1/29

Order No. supplements


0
1
2
3
4

Add. price
None

Type of auxiliary circuit connections


Without
With screw connection (SIGUT, standard)
With screwless connection method (tension spring)

None

0
1
2

Position signaling switches


Without
Option 1

Connected position 1 CO,


test position 1 CO,
disconnected position 1 CO

Option 2

Connected position 3 CO,


test position 2 CO,
disconnected position 1 CO

0
1

None

Shutters
Without
With shutter,
2-part,
lockable

Add "Z" to the complete Order No.


and indicate the appropriate order code(s).

None

A
B

Size I
Size II
Size III

Order No. with "Z"


and additional order code

1234 5 6 7

8 9 10 11 12 13 14 15 16

3WL9 2 1 . . . . . . . . . . Z
@@@

Additional
price

Rated voltage 1000 V AC


Size II, except 4000 A (switching capacity H)
A05
Size III, not necessary with circuit breakers with very high switching capacity A 0 5

Size II, except 4000 A (switching capacity H)

A15

A08
A08
A08

Rated voltage 1150 V AC


Tinned version of the customer's connections on the guide frame1)2)
Only for guide frames with horizontal connection or flange connection
Size I
Size II
Size III

For main circuit connection vertical and main circuit connecting flange see the following page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code, see pages 1/24 to 1/28.
Additional price
1)

Front connections are tinned as standard.

2)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

* You can order this quantity or a multiple thereof.

1/32

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Size

Max. rated circuit breaker


current
In max.

Switching DT
capacity
Icu

kA

Guide frames for 4-pole circuit breakers/


non-automatic air circuit breakers
Order No.
(Order No. supplements
required acc. to
table below)

Basic
price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Vertical main circuit connection


I
I
II
II
II
II
III
III
III
III
III
III

1000
1600
2000
2500
3200
4000
4000
5000
6300
4000
5000
6300

... 66
... 66
... 100
... 100
... 100
... 100
... 100
... 100
... 100
... 130
... 130
... 130

B
B
B
B
B
B
B
B
B
B
B
B

3WL9 211-1BD@@-@@A1
3WL9 211-2BD@@-@@A1
3WL9 212-3BD@@-@@A1
3WL9 212-4BD@@-@@A1
3WL9 212-5BD@@-@@A1
3WL9 212-6BD@@-@@A1
3WL9 213-6BD@@-@@A1
3WL9 213-7BD@@-@@A1
3WL9 213-8BD@@-@@A1
3WL9 213-6BD@@-@@C1
3WL9 213-7BD@@-@@C1
3WL9 213-8BD@@-@@C1

1
1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
62.000
84.000
84.000
119.000
88.000
88.000
124.000

... 66
... 66
... 100
... 100
... 100
... 100

B
B
B
B
B
B

3WL9 211-1BE@@-@@A1
3WL9 211-2BE@@-@@A1
3WL9 212-3BE@@-@@A1
3WL9 212-4BE@@-@@A1
3WL9 212-5BE@@-@@A1
3WL9 213-6BE@@-@@A1

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

30.000
30.000
37.000
47.000
54.000
84.000

Main circuit connection connecting flanges


I
I
II
II
II
III

1000
1600
2000
2500
3200
4000

Number of auxiliary supply connectors

Order No. supplements

Without
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 1/29

Add. price
None

0
1
2
3
4

Type of auxiliary circuit connections


Without
With screw connection (SIGUT, standard)
With screwless connection method (tension spring)

None

0
1
2

Position signaling switches


Without
Option 1

Option 2

Connected position 1 CO,


test position 1 CO,
disconnected position 1 CO
Connected position 3 CO,
test position 2 CO,
disconnected position 1 CO

0
1

None

Shutters
Without
With shutter,
2-part,
lockable

Add "Z" to the complete Order No.


and indicate the appropriate order code(s).

None

A
B

Size I
Size II
Size III

Order No. with "Z"


and additional order code

1234 5 6 7

8 9 10 11 12 13 14 15 16

3WL9 2 1 . . . . . . . . . . Z
@@@

Additional
price

Rated voltage 1000 V AC


Size II, except 4000 A (switching capacity H)
A05
Size III, not necessary with circuit breakers with very high switching capacity A 0 5

Size II, except 4000 A (switching capacity H)

A15

A08
A08
A08

Rated voltage 1150 V AC


Tinned version of the customer's connections on the guide frame1)2)
Only for guide frames with horizontal connection or flange connection
Size I
Size II
Size III

For main circuit connection front, single hole, main circuit connection front, double hole, and main circuit connection horizontal see
the previous page.
All other accessory parts must be ordered by specifying "Z" and the corresponding order code, see pages 1/24 to 1/28.
Additional price
1)

Front connections are tinned as standard.

2)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/33

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
"

Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

NSE0_01610b

Protective devices with device holder and optional measurement


function1)
Type

With protection
function

Measurement
function

ETU15B

LI

Without

3WL9 311-5AA00-0AA2

1 unit 103

0.720

ETU25B

LSI

Without

3WL9 312-5AA00-0AA2

1 unit 103

0.720

ETU27B

LSING

Without

3WL9 312-7AA00-0AA2

1 unit 103

0.720

ETU45B
(without display)

LSIN(G)

Without
C
With measurement B
function Plus

3WL9 314-5AA00-0AA2
3WL9 314-5AA20-0AA2

1
1

1 unit 103
1 unit 103

0.720
0.720

ETU76B

LSIN(G)

Without
C
With measurement B
function Plus

3WL9 317-6AA00-0AA2
3WL9 317-6AA20-0AA2

1
1

1 unit 103
1 unit 103

0.720
0.720

3WL9 31.-.AA.0-0AA1

Rated current modules / Rating plugs2)


For size
I, II

Rated current In (A)


250
315
400
500

B
B
B
B

3WL9 111-0AA51-0AA0
3WL9 111-0AA52-0AA0
3WL9 111-0AA53-0AA0
3WL9 111-0AA54-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.010
0.010
0.010
0.010

630
800
1000

B
B
B

3WL9 111-0AA55-0AA0
3WL9 111-0AA56-0AA0
3WL9 111-0AA57-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

0.010
0.010
0.010

I, II, III

1250
1600

B
B

3WL9 111-0AA58-0AA0
3WL9 111-0AA61-0AA0

1
1

1 unit 103
1 unit 103

0.010
0.010

II, III

2000
2500
3200
4000

B
B
B
B

3WL9 111-0AA62-0AA0
3WL9 111-0AA63-0AA0
3WL9 111-0AA64-0AA0
3WL9 111-0AA65-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.010
0.010
0.010
0.010

III

5000
6300

B
B

3WL9 111-0AA66-0AA0
3WL9 111-0AA67-0AA0

1
1

1 unit 103
1 unit 103

0.010
0.010

GFM AT 45B (only for ETU45B) alarm and tripping

3WL9 111-0AT53-0AA0

1 unit 103

0.030

GFM AT 55B76B (only for ETU76B) alarm and tripping

3WL9 111-0AT56-0AA0

1 unit 103

0.030

4-line displays for ETU45B

3WL9 111-0AT81-0AA0

1 unit 103

0.060

Internal transformers for N conductors Size I


(not for ETU Release 2)
Size II
Including wiring kit
Size III

B
B
B

3WL9 111-0AA11-0AA0
3WL9 111-0AA12-0AA0
3WL9 111-0AA13-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

0.200
0.280
0.500

Internal transformers for N conductors Size I


Only for ETU Release 2
Size II
Including wiring kit
Size III

B
B
B

3WL9 111-0AA14-0AA0
3WL9 111-0AA15-0AA0
3WL9 111-0AA16-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

0.200
0.280
0.500

3WL9 111-0AA2.-0AA0 External transformers for N conductors Size I


(for T5, "Measurement Method" function Size II
see Technical Information at
Size III
www.siemens.com/lowvoltage/support.

B
B
B

3WL9 111-0AA21-0AA0
3WL9 111-0AA22-0AA0
3WL9 111-0AA23-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

0.300
0.380
0.680

External transformers for N conductors Size I


with copper connection pieces
Size II
(for T5, "Measurement Method" function Size III
N S E 0 _ 0 0 9 9 1 a
see Technical Information at
3WL9 111-0AA3.-0AA0 www.siemens.com/lowvoltage/support.

B
B
B

3WL9 111-0AA31-0AA0
3WL9 111-0AA32-0AA0
3WL9 111-0AA33-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

1.600
4.260
8.500

Not for
ETU Release 2

3WL9 111-0AK32-0AA0

1 unit 103

0.280

Only for ETU


Release 2

3WL9 111-0AK34-0AA0

1 unit 103

0.280

= 3 2 0 0 A

N S E 0 _ 0 0 9 9 2 b

3WL9 111-0AA64-0AA0

Ground-fault modules3)
G F M

5 1
g T R IP

A L A R M

A T 4 5 B

J g (s )
.5

T R IP
C

O F F

A L A R M

.4
.3
.2
.1

1 2 Jg
.1
.2
.3
.4
.5

N S E 0 _ 0 1 0 2 7 a

3WL9 111-0AT53-0AA0

Displays

N S E 0 _ 0 1 6 0 9

3WL9 111-0AT81-0AA0

Current transformers for N conductor protection

N S E 0 _ 0 0 9 9 0 a

EMC filters
EMC filters
Common-mode interference suppressor
filters (e.g. in IT networks, caused by frequency converters)
Insertion loss (asymmetric) in the range
40 kHz to 10 MHz >40 dB.
1)

For replacement in existing circuit breakers please specify the circuit


breaker ID No. when ordering.
2)
With the rated current module selected, the maximum rated
current In max of the circuit breaker must not be exceeded.
The following applies In  In max.

3)

For direct measurement of the ground-fault current, e.g. in the neutral point
of the transformer, a 1200 A/1 A current transformer, class 1, is required.
The internal load of the SENTRON 3WL is 0.11 m. If the ground-fault current is to be determined using the vectorial sum of the phases, a current
transformer must be installed in the neutral conductor.
* You can order this quantity or a multiple thereof.

1/34

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

More accessories for electronic releases


NSE0_00983b

Sealable and lockable covers

ETU25B

N S E 0 _ 0 0 9 9 9 a

3WL9 111-0AT45-0AA0

1 unit 103

0.050

For ETU76

3WL9 111-0AT46-0AA0

1 unit 103

0.050

3WL9 111-0AK21-0AA0

1 unit 103

0.050

Remote reset solenoids1)


For mechanical tripped indicator

24 V DC

3WL9 111-0AK03-0AA0

1 unit 103

0.200

48 V DC

3WL9 111-0AK04-0AA0

1 unit 103

0.200

Spare part for option K10 to K13,


see "-Z" + order code, page 1/25.

120 V AC/
125 V DC

3WL9 111-0AK05-0AA0

1 unit 103

0.200

208-250 V AC/
208-250 V DC

3WL9 111-0AK06-0AA0

1 unit 103

0.200

For ETU45B and


ETU76B

3WL9 111-0AK30-0AA0

1 unit 103

0.150

Retrofittable internal wiring for connection of the


external N- and G-transformers to terminal X8
(without male connector, not for ETU Release 2)

3WL9 111-0AK31-0AA0

1 unit 103

0.020

Retrofittable internal wiring for connection of the


external N- and G-transformers to terminal X8
for ETU Release 2 (without male connector)

3WL9 111-0AK33-0AA0

1 unit 103

0.020

3WL9 111-0BA21-0AA0

1 unit 103

0.100

Made by CES

Retrofittable internal CubicleBUS


wiring for connection to terminal X8
(without male connector2))

3WL9 111-0AK0.-0AA0

B
Automatic reset of the reclosing lockout
Spare part for option K01, see "-Z" + order code, page 1/25.

3WL9 111-0AT45-0AA0
F 7

For ETU15B to
ETU45B

NSE00980

Locking devices

3WL9 111-0BA22-0AA0

Interlocking set for


mechanical ON/OFF
Consisting of 2 transparent covers each
for sealing or for attaching padlocks4),
cover with 6.35 mm hole (for tool actuation), lock mount for safety lock for key
operation

Without safety
lock

3WL9 111-0BA22-0AA0

1 unit 103

0.300

Made by IKON

3WL9 111-0BA24-0AA0

1 unit 103

0.300

Locking devices against


unauthorized closing,
in the operator panels

Assembly kit
FORTRESS or
CASTELL3)

3WL9 111-0BA31-0AA0

1 unit 103

0.200

The disconnector unit fulfills the

requirements for main circuit breakers


acc. to EN 60204-1

Made by Ronis
B
Made by KIRKB
Key3)
Made by Profalux B

3WL9 111-0BA33-0AA0
3WL9 111-0BA34-0AA0

1
1

1 unit 103
1 unit 103

0.400
0.270

3WL9 111-0BA35-0AA0

1 unit 103

0.250

Made by CES
Made by IKON

B
B

3WL9 111-0BA36-0AA0
3WL9 111-0BA38-0AA0

1
1

1 unit 103
1 unit 103

0.200
0.200

Assembly kit for


padlocks4)

3WL9 111-0BA41-0AA0
1

1 unit 103

0.360

Made by CES
Made by IKON
Made by KIRKKey3)
Made by Ronis
Made by Profalux

B
B
B

3WL9 111-0BA51-0AA0
3WL9 111-0BA53-0AA0
3WL9 111-0BA57-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

0.300
0.300
0.300

B
B

3WL9 111-0BA58-0AA0
3WL9 111-0BA50-0AA0

1
1

1 unit 103
1 unit 103

0.300
0.227

3WL9 111-0BA71-0AA0

1 unit 103

0.080

Spare part for option S01 to S09,


see "-Z" + order code, page 1/27.

NSE00981

Locking devices against


unauthorized closing,
for withdrawable circuit breakers
3WL9 111-0BA31-0AA0 The disconnector unit fulfills the requirements for main circuit breakers acc. to
EN 60204-1 consisting of lock in the
cabinet door, active in connected
position; function is retained when circuit
breaker is replaced
NSE0_00982
Spare part for option R60, R61, R68,
3WL9 111-0BA53-0AA0 see "-Z" + order code, page 1/27.

Locking devices for operating mechanism handle with padlock4)


Spare part for option S33,
see "-Z" + order code, page 1/27.

NSE00984

Locking devices against movement of


the withdrawable circuit breakers
Safety lock for mounting on the circuit
breaker.

Made by CES
Made by IKON
Made by Profalux
Made by Ronis

B
B
B
B

3WL9 111-0BA73-0AA0
3WL9 111-0BA75-0AA0
3WL9 111-0BA76-0AA0
3WL9 111-0BA77-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.300
0.200
0.300
0.300

Spare part for option S71, S75, S76,


see "-Z" + order code, page 1/27.

Made by KIRKKey3)

3WL9 111-0BA80-0AA0

1 unit 103

0.400

3WL9 111-0BA43-0AA0

1 unit 103

0.360

Made by CES
3WL9 111-0BA71-0AA0 Interlocking systems
2 of the same keys for 3 circuit breakers,
locking device OFF position,
key-operated switch on operator panel.
A maximum of 2 circuit breakers can be
switched on.
NSE0_00986

3WL9 111-0BA76-0AA0
1)

Can only be used in conjunction with "automatic reset of the reclosing lockout", e.g. "Z" + "K01", 3WL9 111-0AK21-0AA0.
2)
Required if communication is retrofitted.

3)
4)

Locks, cylinders and keys must be ordered from the manufacturer.


Padlock not included in the scope of supply.
Start of delivery on request.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/35

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Locking mechanisms
To prevent movement of the withdrawable circuit breakers in disconnected positions,
consisting of Bowden wire and lock
in the cabinet door

NSE0_00987

B
B
B
B

3WL9 111-0BA81-0AA0
3WL9 111-0BA83-0AA0
3WL9 111-0BA85-0AA0
3WL9 111-0BA86-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.800
0.800
0.800
0.800

3WL9 111-0BB12-0AA0

1 unit 103

0.600

Guide frames

3WL9 111-0BB13-0AA0

1 unit 103

0.150

Guide frames

3WL9 111-0BB15-0AA0

1 unit 103

0.150

Fixed-mounted circuit
breakers

3WL9 111-0BB21-0AA0

1 unit 103

2.700

3WL9 111-0BB24-0AA0

1 unit 103

1.130

Module for guide frame B

3WL9 111-0BB22-0AA0

1 unit 103

1.100

3WL9 111-0BB23-0AA0

1 unit 103

0.150

3WL9 111-0BB30-0AA0

1 unit 103

0.100

3WL9 112-8AH47-0AA0

1 unit 103

0.160

B
B
B

3WL9 111-0BB45-0AA0
3WL9 111-0BB46-0AA0
3WL9 111-0BB47-0AA0

1
1
1

1 unit 103
1 unit 103
1 unit 103

0.150
0.220
0.360

Made by CES
Made by IKON
Made by Profalux
Made by Ronis

3WL9 111-0BA83-0AA0 Spare part for option R81, R85,


R86, see "-Z" + order code,
page 1/27.
Not possible in combination with
"Locking device to prevent opening
of the cabinet door" (order code
"R30") or "Locking device to preNSE0_00988
vent movement with the cabinet
3WL9 111-0BB12-0AA0 door open" (order code "R50").
To prevent opening of the
Fixed mounting
Interlocking
cabinet door in ON position
(can be defeated)
Spare part for option S30,
see "-Z" + order code, page 1/27.
To prevent opening of the
cabinet door (can be defeated)
Spare part for option R30,
see "-Z" + order code, page 1/27.
Not possible in combination with
"Locking device to prevent movement of the withdrawable circuit
breakers in disconnected position"
(order codes "R81", "R85" or "R86").
To prevent movement with the
cabinet door open
Spare part for option R50,
see "-Z" + order code, page 1/27.
Not possible in combination with
"Locking device to prevent movement of the withdrawable circuit
breakers in disconnected position"
(order codes "R81", "R85" or "R86").

Interlocks
Mutual mechanical interlocking,
with 2000 mm Bowden wire
(one required for each circuit
breaker)
NSE0_00989

Spare part for option


S55, see "-Z" + order
code, page 1/26.
Module for withdrawable circuit breaker
with guide frame

3WL9 111-0BB21-0AA0

Spare part for option


R55, see "-Z" + order
code, page 1/26.
When ordered separately
Spare part for option
R56, see "-Z" + order
code, page 1/26.
Module for withdrawable circuit breaker
Spare part for option
R57, see "-Z" + order
code, page 1/26.
Adapter for size III
Withdrawable circuit
breaker
Couplings on the circuit breaker
(with ring) for mutual interlocking
Can be used in all circuit breakers
Bowden wires
NSE0_01886

2000 mm
3000 mm
4500 mm

3WL9 112-8HA47-0AA0

* You can order this quantity or a multiple thereof.

1/36

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Test devices
Manual tester Release 2 for electronic releases ETU15B B
to ETU76B

3WL9 111-0AT32-0AA0

1 unit

103

1.100

3WL9 111-0AT44-0AA0

1 unit

103

8.210

3WL9 111-0BA14-0AA0

1 unit

103

0.520

For testing the electronic release functions


Function testers
For testing the tripping characteristics for
electronic releases ETU15B to ETU76B

Capacitor storage devices


Capacitor storage devices
For shunt release
Storage time 5 min

Rated control supply


voltage/rated operational voltage

50/60 Hz V AC V DC
Rated control supply voltage
must match the rated control sup- 220 ... 240
220 ...
ply voltage of the shunt release
250
Suitable also for 3VL and 3WN
circuit breakers

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/37

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Indicators, control elements


B

3WL9 111-0AH01-0AA0

1 unit

103

0.020

3WL9 111-0AH02-0AA0

1 unit

103

0.020

3WL9 111-0AH14-0AA0

1 unit

103

0.080

3WL9 111-0AH07-0AA0

1 unit

103

0.100

3WL9 111-0AH08-0AA0

1 unit

103

0.030

1st block
(3 CO contacts)

3WL9 111-0AH11-0AA0

1 unit

103

0.200

2nd block
(6 CO contacts)

3WL9 111-0AH12-0AA0

1 unit

103

0.400

Ready-to-close signaling switches


1 NO contact
Spare part for option C22,
see "-Z" + order code, page 1/25.
Signaling switches1)2)
Spare part for option C26
and C27, see "-Z" + order
code, page 1/25.

1st or 2nd auxiliary


release

Tripped signaling switches1)2)


1 CO

N S E 0 _ 0 0 9 9 3 a

3WL9 111-0AH01-0AA0 Spare part for option K07, see "-Z" + order code,
page 1/25.

N S E 0 _ 0 0 9 9 4 b

Operating cycles counters,


mechanical3)
Spare part for option C01,
see "-Z" + order code, page 1/25.
Stored energy status signaling switches1)2)
1 NO contact

3WL9 111-0AH02-0AA0

Spare part for option C20,


see "-Z" + order code, page 1/25.
Position signaling
switches for guide
frames
Spare part for option R15
and R16, see "-Z" + order
code, page 1/26.

Electrical ON buttons1)4) With sealing cap


(button+wiring)2),
With CES assembly kit
3WL9 111-0AH07-0AA0 for operator panel.
With IKON assembly kit
Possible only for circuit
breakers with closing
solenoid.
N S E 0 _ 0 0 9 9 5 a

N S E 0 _ 0 0 9 9 6 a

3WL9 111-0AH12-0AA0

3WL9 111-0AJ02-0AA0

1 unit

103

0.150

3WL9 111-0AJ03-0AA0

1 unit

103

0.140

3WL9 111-0AJ05-0AA0

1 unit

103

0.140

3WL9 111-0AJ06-0AA0

1 unit

103

0.100

3WL9 111-0BA72-0AA0

1 unit

103

0.080

Spare part for option C11


and C12, see "-Z" + order
code, page 1/25.
Motor shutdown switches 5)
(mounting on operator panel)
Spare part for option S25,
see "-Z" + order code, page 1/25.

N S E 0

EMERGENCY-STOP pushbuttons
Mushroom pushbutton instead
of the mechanical OFF pushbutton

0 0 9 9 7 a

3WL9 111-0AJ0.-0AA0

Spare part for option S24,


see "-Z" + order code, page 1/25.

NSE00985

3WL9 111-0BA72-0AA0
1)
2)

Not possible with communications interface option, order code "F02" or


"F12".

3)

Only in conjunction with motorized operating mechanism.

4)

Not possible with motor shutdown switch.

X7 manual connector required for circuit breakers or guide frames. If this is


not already available, please order additionally
(see pages 1/29 and 1/39).

5)

Not possible with electrical ON button.

* You can order this quantity or a multiple thereof.

1/38

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Auxiliary conductor connections

NSE00978

Male connectors for circuit breakers $

3WL9 111-0AB01-0AA0

1 unit

103

0.100

Extension for the 1000 V male connector


versions
(male connector must be ordered separately)

3WL9 111-0AB02-0AA0

1 unit

103

0.150

Male connectors and extension for 1000 V

3WL9 111-0AB10-0AA0

1 unit

103

1.000

3WL9 111-0AB03-0AA0

1 unit

103

0.070

3WL9 111-0AB04-0AA0

1 unit

103

0.070

Coding kits for fixed-mounted version (X5 to X8)

3WL9 111-0AB07-0AA0

1 unit

103

0.020

Sliding contact modules for guide frames (

3WL9 111-0AB08-0AA0

1 unit

103

0.100

One-part sliding contact modules for guide


frames Screw connection (SIGUT) )

3WL9 111-0AB18-0AA0

1 unit

103

0.120

Blanking blocks for circuit breakers

3WL9 111-0AB12-0AA0

1 unit

103

0.030

N S E 0 _ 0 1 2 6 8

3WL9 111-0AB01-0AA0

N S E 0 _ 0 1 2 6 9

Auxiliary supply connec- Screw connection


tors for circuit breakers or (SIGUT)
guide frames %
Screwless connec3WL9 111-0AB03-0AA0
tion method (tension
spring)

3WL9 111-0AB04-0AA0

NSE00974

&

3WL9 111-0AB07-0AA0

7 a
9 7
0 0
0 _
E
N S

NSE0_01586

3WL9 111-0AB08-0AA0

3WL9 111-0AB18-0AA0

For a complete auxiliary current connection you must order:


Fixed-mounted version:
Withdrawable version:

$+%+&
$+(+%
or

$+)
* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/39

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Auxiliary releases
Closing solenoids/shunt releases
24 V DC

3WL9 111-0AD06-0AA0

3WL9 111-0AD01-0AA0

1 unit

103

0.700

30 V DC

3WL9 111-0AD02-0AA0

1 unit

103

0.700

48 V DC

3WL9 111-0AD03-0AA0

1 unit

103

0.700

60 V DC

3WL9 111-0AD04-0AA0

1 unit

103

0.700

110 ... 125V DC /110 V AC

3WL9 111-0AD05-0AA0

1 unit

103

0.700

220 V DC/230 V AC

3WL9 111-0AD06-0AA0

1 unit

103

0.700

24 V DC

100 % duty ratio

5 % duty

ratio1)

3WL9 111-0AD11-0AA0

1 unit

103

0.700

3WL9 111-0AD12-0AA0

1 unit

103

0.700

110 ... 125 V DC/110 ... 127 V AC

3WL9 111-0AD13-0AA0

1 unit

103

0.700

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AD14-0AA0

1 unit

103

1.800

24 V DC

3WL9 111-0AE01-0AA0

1 unit

103

0.730

30 V DC

3WL9 111-0AE02-0AA0

1 unit

103

0.730

48 V DC

3WL9 111-0AE03-0AA0

1 unit

103

0.730

60 V DC

3WL9 111-0AE07-0AA0

1 unit

103

0.730

110 ... 125 V DC/110 ... 127 V AC

3WL9 111-0AE04-0AA0

1 unit

103

0.730

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AE05-0AA0

1 unit

103

0.730

380 ... 415 V AC

3WL9 111-0AE06-0AA0

1 unit

103

0.730

48 V DC

NSE01001

3WL9 111-0AE0.-0AA0

NSE01002

Undervoltage release
Instantaneous

3WL9 111-0AE1.-0AA0
Delayed
B

3WL9 111-0AE11-0AA0

1 unit

103

0.740

110 ... 125 V DC/110 ... 127 V AC

48 V DC

3WL9 111-0AE12-0AA0

1 unit

103

0.740

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AE13-0AA0

1 unit

103

0.740

380 ... 415 V AC

3WL9 111-0AE14-0AA0

1 unit

103

0.740

24 ... 30 V DC

3WL9 111-0AF01-0AA0

1 unit

103

1.510

48 ... 60 V DC

3WL9 111-0AF02-0AA0

1 unit

103

1.510

110 ... 125 V DC/110 ... 127 V AC

3WL9 111-0AF03-0AA0

1 unit

103

1.510

220 ... 250 V DC/208 ... 240 V AC

3WL9 111-0AF04-0AA0

1 unit

103

1.510

2 NO + 2 NC

3WL9 111-0AG01-0AA0

1 unit

103

0.180

2 NO

3WL9 111-0AG02-0AA0

1 unit

103

0.080

1 NO + 1 NC

3WL9 111-0AG03-0AA0

1 unit

103

0.070

Operating mechanisms
Motorized operating mechanisms2)

N S E 0 _ 0 1 0 0 3 a

3WL9 111-0AF0.-0AA0

Auxiliary contacts
Auxiliary switch blocks

NSE0_01004

3WL9 111-0AG03-0AA0

1)

Overexcited, i.e. opening time 50 ms (standard > 80 ms).

2)

X7 manual connector required for circuit breakers or guide frames. If this is


not already available, please order additionally (see pages 1/29 and 1/39).

* You can order this quantity or a multiple thereof.

1/40

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Door sealing frames, hoods, shutters


B

3WL9 111-0AP01-0AA0

1 unit

103

0.360

3WL9 111-0AP02-0AA0

1 unit

103

1.600

Size I

3WL9 111-0AP04-0AA0

1 unit

103

0.500

Size II

3WL9 111-0AP06-0AA0

1 unit

103

0.630

Size III

3WL9 111-0AP07-0AA0

1 unit

103

0.860

Size I

3WL9 111-0AP08-0AA0

1 unit

103

0.600

Size II

3WL9 111-0AP11-0AA0

1 unit

103

0.770

Size III

3WL9 111-0AP12-0AA0

1 unit

103

1.070

Size I

3WL9 111-0AS01-0AA0

1 unit

103

1.110

Size II

3WL9 111-0AS02-0AA0

1 unit

103

1.680

Size III

3WL9 111-0AS03-0AA0

1 unit

103

2.980

Size II

3WL9 111-0AS05-0AA0

1 unit

103

3.140

Size III

3WL9 111-0AS06-0AA0

1 unit

103

5.620

Size I

3WL9 111-0AS32-0AA0

1 unit

103

1.850

Size II

3WL9 111-0AS36-0AA0

1 unit

103

2.600

Size III

3WL9 111-0AS38-0AA0

1 unit

103

4.050

Size I

3WL9 111-0AS42-0AA0

1 unit

103

2.340

Size II

3WL9 111-0AS44-0AA0

1 unit

103

3.300

Size III

3WL9 111-0AS46-0AA0

1 unit

103

5.210

3WL9 111-0AR12-0AA0

1 unit

103

0.400

Door sealing frames


Spare part for option T40, see
"-Z" + order code, page 1/25.
Protective covers, IP55
Cannot be used in conjunction
with door sealing frames, hood
removable and can be opened
on both sides
NSE0_01028a

Shutters

3WL9 111-0AP02-0AA0

Spare part for option R21, see


"-Z" + order code, page 1/26.
3-pole

4-pole

NSE0_01006

3WL9 111-0AP0.-0AA0

Arc chute
Arc chute

NSE0_01007

690 V

3WL9 111-0AS0.-0AA0

1000 V / 1150 V
Arc chute covers1)
Parts kit for guide frame
Spare part for option R10, see
"-Z" + order code, page 1/26.
3-pole

NSE0_01008

3WL9 111-0AS3.-0AA0
4-pole

Coding for withdrawable version


Coding for withdrawable version
By customer, for 36 coding variants

NSE0_01009

3WL9 111-0AR12-0AA0
1)

Not available for


- 1000-V version (order code "A05"),
- 1150-V version (order code "A15"),
- DC version,
- 4000 A size II,
- circuit breaker with very high switching capacity C.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/41

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Grounding connection

NSE0 01018a

3WL9 111-0BA02-0AA0

Grounding connection between


the guide frame and the withSize I, II2)
drawable circuit breaker
Size III
For 30 kA ground short-circuit
current1)
Contacting module for guide frame

3WL9 111-0BA01-0AA0

1 unit

103

0.330

3WL9 111-0BA02-0AA0

1 unit

103

0.350

Size I

3WL9 111-0BA05-0AA0

1 unit

103

1.250

Size II2)

3WL9 111-0BA06-0AA0

1 unit

103

1.530

Size III

3WL9 111-0BA07-0AA0

1 unit

103

2.270

Size I

3WL9 111-0BA08-0AA0

1 unit

103

1.500

Size II2)

3WL9 111-0BA04-0AA0

1 unit

103

1.850

Size III

3WL9 111-0BA10-0AA0

1 unit

103

2.950

Support brackets
B
For mounting fixed-mounted circuit breakers on
vertical plane, only for sizes I and II (1 set = 2 units)

3WL9 111-0BB50-0AA0

1 unit

103

7.000

Contacting modules for withdrawable circuit


breakers
3-pole
NSE01019

3WL9 111-0BA07-0AA0
4-pole

NSE-01022

Support brackets

3WL9 111-0BB50-0AA0
1)

For 60 kA ground short-circuit current, order 2.

2)

Can also be used for size II, 4000 A.

* You can order this quantity or a multiple thereof.

1/42

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

CubicleBUS modules1)
Digital output modules with rotary coding switch,
relay outputs

3WL9 111-0AT26-0AA0

1 unit 103

0.240

Digital output modules, configurable, relay outputs

3WL9 111-0AT20-0AA0

1 unit 103

0.310

Digital input module

3WL9 111-0AT27-0AA0

1 unit 103

0.240

Analog output modules

3WL9 111-0AT23-0AA0

1 unit 103

0.240

Zone Selective Interlocking modules

3WL9 111-0AT21-0AA0

1 unit 103

0.240

Breaker Data Parameterization, operation, monitoring and B


Adapters
diagnostics of SENTRON circuit breakers
(BDA)2)
using the local interface; Breaker Data
Adapter, connection cable to the SENTRON
3WL circuit breaker and to the programming
device (e.g. notebook); can be run with
Internet Explorer with JAVA2 VM 1.4.0-01 and
higher

3WL9 111-0AT28-0AA0

1 unit 103

0.900

BDA Plus2)3) Same as BDA, but with additional Ethernet


interface for connection to Ethernet/Intranet/
Internet

3WL9 111-0AT33-0AA0

1 unit 103

1.200

Connection
cables for
BDA Plus

Connection cable for connection of BDA Plus B


to terminal X8 of the SENTRON 3WL circuit
breaker. Required if neither COM15 nor
COM16 nor other external CubicleBUS
modules are available, length 2 m.

3WL9 111-0BC21-0AA0

1 unit 103

0.350

Switch ES
Power
parameterization
software

Calibration, operation, monitoring, and diag- A


nostics of SENTRON circuit breakers via
PROFIBUS DP; runs under Windows 95,
Windows 98, Windows NT, Windows 2000 and
Windows XP Professional, requires additional
PROFIBUS card e.g. CP5613

3ZS2 311-0CC10-0YA0

1 unit 133

0.200

0.2 m long, for connection to SENTRON 3WL B


with COM15/COM16

3WL9 111-0BC04-0AA0

1 unit 103

0.020

1 m long, for connection to SENTRON 3WL


with COM15/COM16

3WL9 111-0BC02-0AA0

1 unit 103

0.050

2 m long, for connection to SENTRON 3WL


with COM15/COM16

3WL9 111-0BC03-0AA0

1 unit 103

0.060

2 m long, for connection to SENTRON 3WL


without COM15/COM16

3WL9 111-0BC05-0AA0

1 unit 103

0.070

1 unit 103

2.600

N S E 0 _ 0 1 0 2 3 a

3WL9 111-0AT23-0AA0

Parameterization systems

N S E 0 _ 0 1 0 2 4 a

3WL9 111-0AT28-0AA0

Accessories for communications


Preassembled
cables for
CubicleBUS
modules

SENTRON
manuals for
communication solutions

Detailed description of the communication


functions for SENTRON circuit breakers.
Installation, connection, commissioning, data
transmission to the PLC, including description
of Switch ES Power and BDA.
PROFIBUS, German, token fee
PROFIBUS, English, token fee
MODBUS, German, token fee
MODBUS, English, token fee
Free download from:
www.siemens.com/lowvoltage/manuals

A5E0151347
A5E0151353

Voltage
380 ... 690 V/100 V, class 0.5
transformers,
3-pole, for
SENTRON
3WL with
measurement
function
Plus4)

3ZX10 12-0WL10-1AB1
3ZX10 12-0WL10-1AC1

3WL9 111-0BB68-0AA0

All communication components, CubicleBUS modules and measurement functions are available for the ETU45B and ETU76B releases.
1)

2)

Each CubicleBUS module is supplied with a 0.2 m factory-fitted cable to


connect the modules with each other. A longer factory-fitted cable is
required for connection to the circuit breaker.

3)

Operation under Windows Vista and Windows 7 on request.

4)

Is required for operation of the measurement function Plus.

A 24 V DC power supply unit is required.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/43

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Retrofitting and spare parts


1

PROFIBUS
retrofit kits

Retrofit kit for PROFIBUS communications


B
including COM15, BSS and set of cables for
all SENTRON 3WL circuit breakers with
ETU45B and ETU76B releases

3WL9 111-0AT12-0AA0

1 unit 103

0.260

COM15
PROFIBUS
module

For ETU45B and ETU76B releases

3WL9 111-0AT15-0AA0

1 unit 103

0.140

For ETU45B and ETU76B releases

3WL9 111-0AT17-0AA0

1 unit 103

0.140

Retrofit kit for MODBUS communications


B
including COM16, BSS and set of cables for
all SENTRON 3WL circuit breakers with
ETU45B and ETU76B releases

3WL9 111-0AT18-0AA0

1 unit 103

0.260

Device

PROFIBUS DP

CubicleBus

NSE-01025

COM16
3WL9 111-0AT15-0AA0 MODBUS
modules
MODBUS IEC
retrofit kits

Breaker status For ETU45B and ETU76B releases


sensor (BSS)

3WL9 111-0AT16-0AA0

1 unit 103

0.120

Measurement For ETU Release 2


function Plus1) (voltage transformer required)

3WL9 111-0AT04-0AA0

1 unit 103

0.250

All communication components, CubicleBUS modules and measurement functions are available for the ETU45B and ETU76B releases.
1)

A measuring accuracy of 3 % is reached if retrofitted.

* You can order this quantity or a multiple thereof.

1/44

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Main conductor connections, fixed mounting (essential accessory)


3WL9 111-0AL06-0AA0

Specified for each connection


Front-accessible
main connections,
single hole at top

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AL01-0AA0
3WL9 111-0AL02-0AA0

1
1

1 unit
1 unit

103
103

1.100
1.600

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AL03-0AA0
3WL9 111-0AL04-0AA0
3WL9 111-0AL05-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.000
3.600
3.500

NSE-01010

Size III, up to 4000 A

3WL9 111-0AL06-0AA0

1 unit

103

6.100

3WL9 111-0AL56-0AA0 Front-accessible

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AL51-0AA0
3WL9 111-0AL52-0AA0

1
1

1 unit
1 unit

103
103

1.000
1.300

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B

3WL9 111-0AL53-0AA0
3WL9 111-0AL54-0AA0
3WL9 111-0AL55-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.800
3.100
3.000

main connections,
single hole at bottom

3WL9 111-0AL14-0AA0

Size III, up to 4000 A

B
B

3WL9 111-0AL56-0AA0

1 unit

103

5.200

Front-accessible
main connections,
acc. to DIN 43673,
double hole at top

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AL07-0AA0
3WL9 111-0AL08-0AA0

1
1

1 unit
1 unit

103
103

1.400
2.000

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AL11-0AA0
3WL9 111-0AL12-0AA0
3WL9 111-0AL13-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.400
4.500
4.400

Size III, up to 4000 A

3WL9 111-0AL14-0AA0

1 unit

103

7.800

Front-accessible
main connections,
acc. to DIN 43673,
double hole at bottom

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AL57-0AA0
3WL9 111-0AL58-0AA0

1
1

1 unit
1 unit

103
103

1.300
1.700

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AL61-0AA0
3WL9 111-0AL62-0AA0
3WL9 111-0AL63-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.000
3.700
3.600

Size III, up to 4000 A

3WL9 111-0AL64-0AA0

1 unit

103

6.400

Rear vertical main


connections

Size I1), up to 1600 A

3WL9 111-0AM01-0AA0

1 unit

103

0.500

Size II2), up to 3200 A

3WL9 111-0AM02-0AA0

1 unit

103

2.200

Size III, up to 6300 A

3WL9 111-0AM03-0AA0

1 unit

103

5.000

NSE-01011

3WL9 111-0AL64-0AA0

NSE-01012

3WL9 111-0AM03-0AA0

1)

In the case of vertical connection size I, up to 1000 A


one 3WL9 1110AM01-0AA0 vertical connection is required,
up to 1600 A two 3WL9 111-0AM01-0AA0 vertical connections are
required.

2)

In the case of vertical connection size II, up to 2500 A


one 3WL9 1110AM02-0AA0 vertical connection is required,
up to 3200 A two 3WL9 111-0AM02-0AA0 vertical connections are
required.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/45

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Main conductor connections, withdrawable versions


(essential accessory)
Specified for each connection

NSE-01013

3WL9 111-0AN06-0AA0

Front-accessible
main connections,
Size I, up to 1000 A
single hole at top or Size I, 1250 to 1600 A
at bottom1)
Size II, up to 2000 A
Size II, up to 2500 A
Size II, up to 3200 A
Front-accessible
main connections,
acc. to DIN 43673,
double hole at top or
at bottom1)

NSE-01014

B
B

3WL9 111-0AN01-0AA0
3WL9 111-0AN02-0AA0

1
1

1 unit
1 unit

103
103

1.000
1.300

B
B
B

3WL9 111-0AN03-0AA0
3WL9 111-0AN04-0AA0
3WL9 111-0AN05-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.800
3.100
3.000

Size III, up to 4000 A

3WL9 111-0AN06-0AA0

1 unit

103

5.200

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AN07-0AA0
3WL9 111-0AN08-0AA0

1
1

1 unit
1 unit

103
103

1.300
1.700

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN11-0AA0
3WL9 111-0AN12-0AA0
3WL9 111-0AN13-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.000
3.700
3.600

Size III, up to 4000 A

3WL9 111-0AN14-0AA0

1 unit

103

6.400

Size I

3WL9 111-0AN41-0AA0

1 unit

103

0.700

Size II

3WL9 111-0AN42-0AA0

1 unit

103

1.350

Size III

3WL9 111-0AN43-0AA0

1 unit

103

2.420

Size I

3WL9 111-0AN44-0AA0

1 unit

103

1.200

Size II

3WL9 111-0AN45-0AA0

1 unit

103

2.200

Size III

3WL9 111-0AN46-0AA0

1 unit

103

3.200

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AN15-0AA0
3WL9 111-0AN16-0AA0

1
1

1 unit
1 unit

103
103

0.660
0.870

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN17-0AA0
3WL9 111-0AN18-0AA0
3WL9 111-0AN21-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.150
1.490
2.580

3WL9 111-0AN14-0AA0
Supports
for front and DIN
connecting bars
3-pole for 3 bars

4-pole for 4 bars

Rear vertical main


connections
NSE-01017

3WL9 111-0AN41-0AA0

NSE-01015

3WL9 111-0AN23-0AA0

Size III, up to 5000 A

3WL9 111-0AN22-0AA0

1 unit

103

6.380

Size III, up to 6300 A


(3 busbar connection
pieces for 3-pole circuit
breakers)

3WL9 111-0AN23-0AA0

1 unit

103

19.170

Size III, up to 6300 A,


at top
(4 busbar connection
pieces for 4-pole circuit
breakers)

3WL9 111-0AN20-0AA0

1 unit

103

18.410

Size III, up to 6300 A,


at bottom
(4 busbar connection
pieces for 4-pole circuit
breakers)

3WL9 111-0AN10-0AA0

1 unit

103

18.300

B
B

3WL9 111-0AN32-0AA0
3WL9 111-0AN33-0AA0

1
1

1 unit
1 unit

103
103

0.630
0.770

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN34-0AA0
3WL9 111-0AN35-0AA0
3WL9 111-0AN36-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.020
1.240
2.170

Rear horizontal main Size I, up to 1000 A


connections
Size I, 1250 to 1600 A

NSE-01016

Connecting flanges

Size III, up to 5000 A

3WL9 111-0AN37-0AA0

1 unit

103

3.860

Size I, up to 1000 A
Size I, 1250 to 1600 A

B
B

3WL9 111-0AN24-0AA0
3WL9 111-0AN25-0AA0

1
1

1 unit
1 unit

103
103

0.610
0.640

Size II, up to 2000 A


Size II, up to 2500 A
Size II, up to 3200 A

B
B
B

3WL9 111-0AN26-0AA0
3WL9 111-0AN27-0AA0
3WL9 111-0AN28-0AA0

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.980
1.020
1.310

Size III, up to 4000 A

3WL9 111-0AN31-0AA0

1 unit

103

2.370

3WL9 111-0AN24-0AA0
1)

When using front-accessible main connections


(withdrawable circuit breakers) supports are required.

* You can order this quantity or a multiple thereof.

1/46

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Designation

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Conversion sets
For converting fixed-mounted circuit breakers into withdrawable circuit breakers
Guide frames and sliding contact modules must be ordered separately.
Number of poles

Size

3-pole

3WL9 111-0BC11-0AA0

1 unit 103

5.100

II

3WL9 111-0BC12-0AA0

1 unit 103

5.900

III

3WL9 111-0BC13-0AA0

1 unit 103

8.100

3WL9 111-0BC14-0AA0

1 unit 103

6.400

II

3WL9 111-0BC15-0AA0

1 unit 103

6.450

III

3WL9 111-0BC16-0AA0

1 unit 103

10.700

4-pole

Main contact elements


You must specify the circuit breaker ID No. when ordering!
Specified for each connection (depending on the number of poles on the circuit breaker, order 3 or 4 units)

NSE-01021

1)

Sizes

In max

Order No. is automatically adapted


to the circuit breaker ID number

Up to 1600 A

3WL9 111-0AM90
L1Y1)

1 unit 103

2.800

II

Up to 2500 A

3WL9 111-0AM91
L1Y1)

1 unit 103

5.870

II

Up to 4000 A

3WL9 111-0AM92
L1Y1)

1 unit 103

7.700

III

Up to 6300 A

3WL9 111-0AM93
L1Y1)

1 unit 103

13.740

Please specify the circuit breaker ID No. in plain text when ordering.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/47

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts
Schematics in as-supplied state

Version

Size

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Withdrawable short-circuiting, grounding and bridging units


NSE0_01118

L1 L2 L3

Top and
bottom
parts of
system are
shortcircuited
and
grounded

(as-supplied state)
N

Up to 1600 A I

3WL9 111-0BD01-0AA0

1 unit

103

30.000

Up to 3200 A II

3WL9 111-0BD03-0AA0

1 unit

103

40.500

Up to 6300 A III

3WL9 111-0BD05-0AA0

1 unit

103

65.000

Up to 1600 A I

3WL9 111-0BD02-0AA0

1 unit

103

35.000

Up to 3200 A II

3WL9 111-0BD04-0AA0

1 unit

103

46.000

Up to 6300 A III

3WL9 111-0BD06-0AA0

1 unit

103

70.000

4-pole

NSE0_01119

NSE0_01113

3-pole

L1 L2 L3

NSE0_01112

NSE0_01119

NSE0_01113

L1 L2 L3

Top part of system is short-circuited and grounded,


infeed from bottom

NSE0_01122a

Top and bottom parts of system are short-circuited and grounded


(as-supplied state)

L1 L2 L3

L1 L2 L3
NSE0_01114

NSE0_01123a

NSE0_01115

Withdrawable bridging unit, infeed and outgoing terminals are permanently


connected to each other

L1 L2 L3

NSE0_01121

NSE0_01116

L1 L2 L3

NSE0_01120

L1 L2 L3

NSE0_01117

NSE0_01118

Conversion for the following applications is possible

Bottom part of system is short-circuited and grounded,


infeed from top

* You can order this quantity or a multiple thereof.

1/48

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Air Circuit Breakers/Non-Automatic Air Circuit Breakers up to 6300 A (AC)
Accessories and Spare Parts

Options
Structure of the Order No.
3WL1

Example
5. position:

>>> >>>>> >>>>

Size

Size II

6. and 7th posi- Max. rated circuit


tions:
breaker current
In max

They are used as an unambiguous means of communication for


various purposes:

In max = 2000 A

Offer processing
Selection and configuration
Order processing
Orders
Order confirmation
Processing of products for storage
Order processing in supply locations
Supply and dispatch
Reporting and planning
Service and warranty

8. position:

Switching capacity High breaking capacity


class
"H": 100 kA

9. position:

Electronic release

ETU76B with pixel graphics


display ...

10. position:

Electronic release
supplement

... with ground-fault protection

11. position:

Number of poles

Three-pole

12. position:

Installation type

Fixed mounting, main connections on rear, vertical

13. position:

Operating mechanism

Manual operating mechanism


with mechanical closing

14. position:

1. Auxiliary release Shunt release


50/60 Hz 110 V AC

15. position:

2. Auxiliary release Without 2nd auxiliary release

16. position:

Auxiliary switches

An important prerequisite for


computer-based order processing is that order numbers must
be structured according to standardized criteria.

The standardized structure


ensures that only one Order No.
has to be administered for one
device.

This saves time and effort during


planning, configuring, ordering
and stock keeping, and consequently above all it saves costs.

2 NO contact + 2 NC contact

The example opposite explains


the various positions within an
Order No.

Accessories: with first order (components are already mounted)


3WL1

Example
"Z" with order code

Additional accessory components can be ordered readymounted.

These supplements are identified by "Z".

>

Communications interface
"Standard" + Breaker Status Sensor (BSS)
+ communication module COM15 for connection to PROFIBUS DP

Even with additional components, one Order No. is sufficient.

Accessories: for retrofitting (components for subsequent fitting)


Example
3WL9

Additional accessories which are


not intended to be readymounted in the factory, such as
spare parts for storage, can also
be ordered separately from the
circuit breaker.

Interlocking set for mechanical ON/OFF


without lock

Accessories for retrofitting are


identified by the Order No. stem
3WL9.

Documentation
Operating manual
Complete set

German/English
French/Italian
Spanish/Portuguese

Order No.
Order No.
Order No.

3ZX18 12-0WL00-0AN1
3ZX18 12-0WL00-0AJ1
3ZX18 12-0WL00-0AL1

Manuals
Communication

German
English

Order No.
Order No.

A5E0151347
A5E0151353

Delivery time class C


On request
On request

Free download of documentation from


www.siemens.com/lowvoltage/manuals

More information
Up-to-date information on the Internet at:
www.siemens.com/sentron

Siemens LV 10.1 2011

1/49

Siemens AG 2011

Air Circuit Breakers


3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)
3- and 4-pole, fixed-mounted versions

Selection and ordering data


For general data see page 1/6.
Size

Max. rated circuit breaker DT


current
In max.
A

3-pole non-automatic air circuit


breakers

DC

Order No.
For Order No. supplements,
see page 1/23

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Horizontal main circuit connection


II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@32-....
3WL12 20-8@@32-....
3WL12 40-8@@32-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

56.000
56.000
64.000

B
B
B

3WL12 10-8@@31-....
3WL12 20-8@@31-....
3WL12 40-8@@31-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

56.000
56.000
85.000

B
B

3WL12 10-8@@33-....
3WL12 20-8@@33-....

1
1

1 unit
1 unit

103
103

56.000
56.000

B
B

3WL12 10-8@@34-....
3WL12 20-8@@34-....

1
1

1 unit
1 unit

103
103

56.000
56.000

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Vertical main circuit connection


II
II
II

1000
2000
40001)

Front main circuit connection, single hole


II
II

1000
2000

Front main circuit connection, double hole


II
II

1000
2000

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic release

Add. price
None

AA

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing

Size

None

1AA2

Max. rated circuit breaker DT


current
In max.
A

4-pole non-automatic air circuit


breakers

DC

Order No.
For Order No. supplements,
see page 1/23

Price
per PU

kg

Horizontal main circuit connection


II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@42-....
3WL12 20-8@@42-....
3WL12 40-8@@42-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

67.000
67.000
77.000

B
B
B

3WL12 10-8@@41-....
3WL12 20-8@@41-....
3WL12 40-8@@41-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

75.000
75.000
103.000

B
B

3WL12 10-8@@43-....
3WL12 20-8@@43-....

1
1

1 unit
1 unit

103
103

67.000
67.000

B
B

3WL12 10-8@@44-....
3WL12 20-8@@44-....

1
1

1 unit
1 unit

103
103

67.000
67.000

13 14 15 16

Additional price

Vertical main circuit connection


II
II
II

1000
2000
40001)

Front main circuit connection, single hole


II
II

1000
2000

Front main circuit connection, double hole


II
II

1000
2000

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic release

Add. price
None

AA

Standard Order No. supplements (for further Order No. supplements, see page 1/23)
Manual operating mechanism with mechanical closing
Add "Z" to the complete Order No.
and indicate the appropriate order code(s).

Rated voltage 1000 V DC


Size II

Up to 2000 A

Size II

Up to 4000 A

None

1AA2
Order No. with "Z"
and additional order code

Note:
For voltages over 600 V use the version for 1000 V DC rated
voltage: Order with "-Z" and order code "A05".
All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see "3WL Air circuit
breakers/non-automatic air circuit breakers up to 6300 A (AC)",
"Options", page 1/24 onwards.

1234 5 6 7

8 9 10 11 12

3WL1 2 . 0 8 . . . . . . . . Z
@@@

3-pole

4-pole

A05

A05

An external overload and short-circuit protection device is available from the company "mat" for the SENTRON 3WL non-automatic air circuit breakers.
Available only directly from the company mat Maschinen- und
Anlagentechnik (for address see page 1/52).

Additional price
1)

Provisions to dissipate heat must be made on the line side.

2)

For permissible rated short-time current Icw and short-circuit switching


capacity Icc for non-automatic air circuit breakers see page 1/3.
* You can order this quantity or a multiple thereof.

1/50

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)
3-pole, withdrawable versions

Selection and ordering data


Size

Max. rated circuit breaker DT


current
In max.
A

3-pole non-automatic air circuit


breakers
Order No.
For Order No. supplements,
see page 1/23

DC

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/53)
II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@35-....
3WL12 20-8@@35-....
3WL12 40-8@@35-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

60.000
60.000
68.000

B
B
B

3WL12 10-8@@36-....
3WL12 20-8@@36-....
3WL12 40-8@@36-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

91.000
91.000
113.000

B
B
B

3WL12 10-8@@37-....
3WL12 20-8@@37-....
3WL12 40-8@@37-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

91.000
91.000
121.000

B
B
B

3WL12 10-8@@38-....
3WL12 20-8@@38-....
3WL12 40-8@@38-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

91.000
91.000
113.000

With guide frames, horizontal main circuit


connection
II
II
II

1000
2000
40001)

With guide frames, vertical main circuit


connection
II
II
II

1000
2000
40001)

With guide frames, connecting flanges


II
II
II

1000
2000
40001)

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic release

Add. price
None

AA

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing

Add "Z" to the complete Order No.


and indicate the appropriate order code(s).

None

1AA2

Order No. with "Z"


and additional order code

1234 5 6 7

8 9 10 11 12

13 14 15 16

3WL1 2 . 0 8 . . 3 . . . . . Z
@@@

Additional price
3-pole

Rated voltage 1000 V DC


Size II4)

Up to 2000 A

A05

Size II4)

Up to 4000 A

A05

A08

Tinned version of the customer's connections on the guide frame3)


Only for circuit breakers in withdrawable version with horizontal connection or flange connection.
The normal delivery time increases to 15 work days.
Size II

Note:
For voltages over 600 V use the version for 1000 V DC rated
voltage; order with "-Z" and order code "A05".
All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see "3WL Air circuit
breakers/non-automatic air circuit breakers up to 6300 A (AC)",
"Options", page 1/24 onwards.

An external overload and short-circuit protection device is available from the company "mat" for the SENTRON 3WL non-automatic air circuit breakers.
Available only directly from the company mat Maschinen- und
Anlagentechnik (for address see page 1/52).

Additional price
1)

Provisions to dissipate heat must be made on the line side.

2)

For permissible rated short-time current Icw and short-circuit switching


capacity Icc for non-automatic air circuit breakers see page 1/3.

3)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

4)

If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/51

Siemens AG 2011

Air Circuit Breakers


3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)
4-pole, withdrawable versions

Selection and ordering data


Size

Max. rated circuit breaker DT


current
In max.
A

4-pole non-automatic air circuit


breakers
Order No.
For Order No. supplements,
see page 1/23

DC

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Without guide frames


(for guide frames, see page 1/53)
II
II
II

1000
2000
40001)

B
B
B

3WL12 10-8@@45-....
3WL12 20-8@@45-....
3WL12 40-8@@45-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

75.000
75.000
82.000

B
B
B

3WL12 10-8@@46-....
3WL12 20-8@@46-....
3WL12 40-8@@46-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

109.000
109.000
136.000

B
B
B

3WL12 10-8@@47-....
3WL12 20-8@@47-....
3WL12 40-8@@47-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

109.000
109.000
146.000

B
B
B

3WL12 10-8@@48-....
3WL12 20-8@@48-....
3WL12 40-8@@48-....

1
1
1

1 unit
1 unit
1 unit

103
103
103

109.000
109.000
136.000

With guide frames, horizontal main circuit


connection
II
II
II

1000
2000
40001)

With guide frames, vertical main circuit


connection
II
II
II

1000
2000
40001)

With guide frames, connecting flanges


II
II
II

1000
2000
40001)

Non-automatic air circuit breakers2)

Order No. supplements

Without electronic release

Add. price
None

AA

Standard Order No. supplements (for further Order No. supplements for circuit breakers and guide frames, see page 1/23)
Manual operating mechanism with mechanical closing
Add "Z" to the complete Order No.
and indicate the appropriate order code(s).

None

1AA2
Order No. with "Z"
and additional order code

1234 5 6 7

8 9 10 11 12

13 14 15 16

3WL1 2 . 0 8 . . 4 . . . . . Z
@@@

Additional
price
4-pole

Rated voltage 1000 V DC


Size II4)

Up to 2000 A

A05

Size II4)

Up to 4000 A

A05

A08

Tinned version of the customer's connections on the guide frame3)


Only for circuit breakers in withdrawable version with horizontal connection or flange connection.
The normal delivery time increases to 15 work days.
Size II

Note:
For voltages over 600 V use the version for 1000 V DC rated
voltage; order with "-Z" and order code "A05".
All other accessory parts must be ordered by specifying "Z"
and the corresponding order code, see "3WL Air circuit
breakers/non-automatic air circuit breakers up to 6300 A (AC)",
"Options", page 1/24 onwards.
Additional price
1)

Provisions to dissipate heat must be made on the line side.

2)

For permissible rated short-time current Icw and short-circuit switching


capacity Icc for non-automatic air circuit breakers see page 1/3.

3)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

4)

If ordering withdrawable circuit breaker and guide frame separately, specify order code "A05" for withdrawable circuit breaker and guide frame.

An external overload and short-circuit protection device is available from the company "mat" for the SENTRON 3WL non-automatic air circuit breakers.
Available only directly from the company mat Maschinen- und
Anlagentechnik5).

5)

mat Maschinen- und Anlagentechnik


Dr. Becker GmbH
Rudolf-Diesel-Strae 22
22941 Bargteheide
Germany
Tel.: +49 (45 32) 20 21-01
Fax: +49 (45 32) 20 21-21
E-mail: info@m-a-t.de
Internet: www.m-a-t.de

* You can order this quantity or a multiple thereof.

1/52

Siemens LV 10.1 2011

Siemens AG 2011

Air Circuit Breakers


3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)
Accessories and Spare Parts

Selection and ordering data


Guide frames for DC non-automatic air circuit breakers
Size

Max. rated circuit breaker current


In max

DT

For 3-pole non-automatic air circuit breakers


Order No.
(Order No. supplements
required acc. to table below)

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Front main circuit connection, single hole


II

2000

3WL9 212-3DA@@-@@A1

1 unit

103

31.000

3WL9 212-3DB@@-@@A1

1 unit

103

31.000

B
B

3WL9 212-3DC@@-@@A1
3WL9 212-6DC@@-@@A1

1
1

1 unit
1 unit

103
103

31.000
60.000

B
B

3WL9 212-3DD@@-@@A1
3WL9 212-6DD@@-@@A1

1
1

1 unit
1 unit

103
103

31.000
60.000

B
B

3WL9 212-3DE@@-@@A1
3WL9 212-6DE@@-@@A1

1
1

1 unit
1 unit

103
103

31.000
60.000

Front main circuit connection, double hole


II

2000

Horizontal main circuit connection


II
II

2000
4000

Vertical main circuit connection


II
II

2000
4000

Main circuit connection connecting flanges


II
II

2000
4000

Order No. supplements

Number of auxiliary supply connectors

Add. price
3-pole

Without
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 1/29

None

0
1
2
3
4

Type of auxiliary circuit connections


Without
With screw connection (SIGUT, standard)
With screwless connection method (tension spring)

None

0
1
2

Position signaling switches


Without
Option 1

Option 2

Connected 1 CO contact,
test 1 CO contacts,
disconnected 1 CO contact
Connected 3 CO contacts,
test 2 CO contacts,
disconnected 1 CO contact

0
1

None

Shutters
Without
With shutter, 2 parts, lockable
Add "Z" to the complete Order No.
and indicate the appropriate order code(s).

None

A
B
Order No. with "Z"
and additional order code

1234 5 6 7

8 9 10 11 12

13 14 15 16

3WL9 2 1 2 . . . . . . . A1 Z
@@@

Add.
price

Rated voltage 1000 V DC


Size II

A05

A08

Tinned version of the customer's connections on the guide frame1)


Only for guide frames with horizontal connection or flange connection
Size II

Guide frames for 4-pole DC non-automatic air circuit breakers


All other accessory parts must be ordered by specifying "Z" and the corresponding order code, see "3WL Air circuit breakers/
Non-Automatic Air circuit breakers up to 6300 A (AC)", "Options", page 1/24 onwards.
Additional price
1)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

1/53

Siemens AG 2011

Air Circuit Breakers


3WL Non-Automatic Air Circuit Breakers up to 4000 A (DC)
Accessories and Spare Parts
Size

Max. rated circuit breaker current


In max

DT

For 4-pole non-automatic air circuit breakers


Order No.
(Order No. supplements
required acc. to table below)

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Front main circuit connection, single hole


II

2000

3WL9 212-3EA@@-@@A1

1 unit

103

37.000

3WL9 212-3EB@@-@@A1

1 unit

103

37.000

B
B

3WL9 212-3EC@@-@@A1
3WL9 212-6EC@@-@@A1

1
1

1 unit
1 unit

103
103

37.000
84.000

B
B

3WL9 212-3ED@@-@@A1
3WL9 212-6ED@@-@@A1

1
1

1 unit
1 unit

103
103

37.000
84.000

B
B

3WL9 212-3EE@@-@@A1
3WL9 212-6EE@@-@@A1

1
1

1 unit
1 unit

103
103

37.000
84.000

13 14 15 16

Add.
price

Front main circuit connection, double hole


II

2000

Horizontal main circuit connection


II
II

2000
4000

Vertical main circuit connection


II
II

2000
4000

Main circuit connection connecting flanges


II
II

2000
4000

Order No. supplements

Number of auxiliary supply connectors

Add. price
4-pole

Without
1 connector
2 connectors
3 connectors
4 connectors
For required number of auxiliary supply connectors,
see table on page 1/29

None

0
1
2
3
4

Type of auxiliary circuit connections


Without
With screw connection (SIGUT, standard)
With screwless connection method (tension spring)

None

0
1
2

Position signaling switches


Without
Option 1

Connected 1 CO contact,
test 1 CO contacts,
disconnected 1 CO contact

Option 2

Connected 3 CO contacts,
test 2 CO contacts,
disconnected 1 CO contact

0
1

None

Shutters
Without
With shutter, 2 parts, lockable
Add "Z" to the complete Order No.
and indicate the appropriate order code(s).

None

A
B
Order No. with "Z"
and additional order code

1234 5 6 7

8 9 10 11 12

3WL9 2 1 2 . . . . . . . A1 Z
@@@

Rated voltage 1000 V DC


Size II

A05

A08

Tinned version of the customer's connections on the guide frame1)


Only for guide frames with horizontal connection or flange connection
Size II

For guide frames for 3-pole DC non-automatic air circuit breakers see previous page
All other accessory parts must be ordered by specifying "Z" and the corresponding order code, see "3WL Air circuit breakers/
Non-Automatic Air circuit breakers up to 6300 A (AC)", "Options", page 1/24 onwards.
Additional price
1)

The permissible temperature-rise limits according to IEC 60947-2 are 5 K


lower for a tin surface than for a silver surface.

* You can order this quantity or a multiple thereof.

1/54

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers

2/2

Introduction

2/6
2/10
2/34
2/55
2/59

3VL Molded Case Circuit Breakers


up to 1600 A
Introduction
3-pole
4-pole
Options
Accessories and spare parts

Ch.12

SENTRON Transfer Control


Devices for ATSE
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


Introduction

Overview

Type

VL160X/3VL1

VL160/3VL2

VL250/3VL3

VL400/3VL4

16 ... 160

50 ... 160

200 ... 250

200 ... 400

Molded case circuit breakers


3VL molded case circuit breakers up to 1600 A
Rated current In
at 50 C ambient temperature

Number of poles

690
500

690
500

690
600

690
600

690
600

690
600

690
600

690
600

----

----

mm
mm
mm
mm

105
157
81
107

139
157
81
107

105
175
81
107

139
175
81
107

105
175
81
107

139
175
81
107

139
279
102
138

183
279
102
138

Up to 240 V AC
Up to 415 V AC
Up to 440 V AC
Up to 500/525 V AC
Up to 690 V AC

kA
kA
kA
kA
kA

65/65
55/55
25/20
18/14
8/43)

65/65
55/55
25/20
25/20
12/6

65/65
55/55
25/20
25/20
12/6

65/65
55/55
35/26
25/20
15/8

Up to 250 V DC4)
Up to 500 V DC4)
Up to 600 V DC4)

kA
kA
kA

30/30
---

32/32
---

32/32
---

32/32
---

kA
kA

25
83)

25
12

25
12

35
20

Up to 240 V AC
Up to 415 V AC
Up to 440 V AC
Up to 500/525 V AC
Up to 690 V AC

kA
kA
kA
kA
kA

100/75
70/70
42/32
30/23
12/63)

100/75
70/70
50/38
40/30
12/6

100/75
70/70
50/38
40/30
12/6

100/75
70/70
50/38
40/30
15/8

Up to 250 V DC4)
Up to 500 V DC4)
Up to 600 V DC4)

kA
kA
kA

30/30
30/30
--

32/32
32/32
--

32/32
32/32
--

32/32
32/32
--

NEMA breaking capacity5)


Up to 480 V AC
Up to 600 V AC

kA
kA

42
123)

50
12

50
12

50
20

Up to 240 V AC
Up to 415 V AC
Up to 440 V AC
Up to 500/525 V AC
Up to 690 V AC

kA
kA
kA
kA
kA

------

200/150
100/75
75/50
50/38
12/6

200/150
100/75
75/50
50/38
12/6

200/150
100/75
75/50
50/38
15/8

Up to 250 V DC4)
Up to 500 V DC4)
Up to 600 V DC4)

kA
kA
kA

----

32/32
32/32
32/32

32/32
32/32
32/32

32/32
32/32
32/32

NEMA breaking capacity5)


Up to 480 V AC
Up to 600 V AC

kA
kA

---

75
12

75
12

75
20

Rated operational voltage Ue


50/60 Hz AC
DC1)

V
V

Electronic releases
Thermal-magnetic
Electronic LCD ETU/ETU
Replaceable
PROFIBUS module COM20
Dimensions
C

D
N S E 0 _ 0 1 1 5 9

A
B

A
B
C
D

Switching capacity Icu/Ics


RMS value acc. to IEC 60947-2
Standard switching capacity N2)

NEMA breaking capacity5)


Up to 480 V AC
Up to 600 V AC
High switching capacity

H2)

Very high switching capacity L2)

Available
-- Not available

For 3VL molded case circuit breakers according to UL 489 see


Catalog LV 16.

2/2

Siemens LV 10.1 2011

1)

Rated DC voltage applies only for circuit breakers with thermalmagnetic release.

Siemens AG 2011

Molded Case Circuit Breakers


Introduction

VL630/3VL5

VL800/3VL6

VL1250/3VL7

VL1600/3VL8

ATC5300

Transfer control devices


3VL molded case circuit breakers up to 1600 A
315 ... 630

800

SENTRON transfer control


devices for ATSE
1000 ... 1250

1600

see "Monitoring Devices" chapter.

690
600

690
600

690
--

690
--

690
--

690
--

690
--

690
--

190
279
102
138

253
279
102
138

190
406
114
151

253
406
114
151

229
406
152
207

305
406
152
207

229
406
152
207

305
406
152
207

65/65
55/55
35/26
25/20
20/10

65/65
55/55
35/26
25/20
20/10

65/35
55/28
35/26
25/20
20/10

65/35
55/28
35/26
25/20
20/10

30/30
---

----

----

----

25
20

25
20

25
20

25
20

100/75
70/70
50/38
40/30
20/10

100/75
70/70
50/38
40/30
20/10

100/50
70/35
50/38
40/30
30/15

100/50
70/35
50/38
40/30
30/15

30/30
30/30
--

----

----

----

50
30

50
30

50
30

50
30

200/150
100/75
75/50
50/38
20/10

200/150
100/75
75/50
50/38
20/10

200/100
100/50
75/50
50/38
35/17

200/100
100/50
75/50
50/38
35/17

30/30
30/30
30/30

----

----

----

65
35

65
35

65
35

65
35

2)

At 240 V AC, 415 V AC and 525 V AC max. 5 % overvoltage,


at 440 V AC, 500 V AC and 690 V AC max. 10 % overvoltage,
at 250/500/600 V DC max. 5 % overvoltage.
3) Rated current I  25 A.
n

4)

The maximum permitted DC voltage for each conducting path needs to be taken
into account for DC switching applications; see Technical Information at
www.siemens.com/lowvoltage/support; time constant t = 15 ms.
5) The NEMA breaking capacity can be found on the rating plate of each IEC circuit
breaker.

Siemens LV 10.1 2011

2/3

Siemens AG 2011

Molded Case Circuit Breakers


Introduction

10

10
11

12

13

NSE0_02087b

$
%
&
(
)
*
+
,
.
/
0
1
2
3
4
5
6
7
8
9
:

2/4

Withdrawable/plug-in bases (pages 2/70 to 2/75)


Side panels for withdrawable version (pages 2/70 to 2/75)
Phase barriers (pages 2/77 to 2/82)
Flared front busbar connecting bars (pages 2/77 to 2/82)
Straight connecting bars (pages 2/77 to 2/82)
Circular conductor terminals for Al/Cu (pages 2/77 to 2/79)
Box terminals for Cu (pages 2/77 to 2/82)
Extended connection covers (terminal covers) (pages 2/77 to 2/82)
Standard connection covers (terminal covers) (pages 2/77 to 2/82)
Masking frames/cover frames for door cutout (pages 2/94 to 2/97)
Motorized operating mechanisms with stored energy mechanism (pages 2/66)
Front-operated rotary operating mechanisms (pages 2/62 to 2/65)
Door-coupling rotary operating mechanisms (pages 2/62 to 2/65)
SENTRON 3VL circuit breakers (pages 2/10 to 2/53)
Internal accessories (pages 2/55, 2/56, 2/59 to 2/61)
Electronic overcurrent releases LCD ETU (pages 2/20, 2/24, 2/28, 2/44 and 2/46)
Electronic releases with communication function (pages 2/12 to 2/28, 2/40 to 2/50)
Thermal/magnetic overcurrent releases (pages 2/10 to 2/12, 2/30, 2/34 to 2/38, 2/52)
RCD modules (page 2/76)
Rear terminals flat and round (pages 2/77 to 2/82)
COM20 communication modules to the PROFIBUS DP (page 2/98)
Battery power supplies with test function for electronic releases (pages 2/84 to 2/88)

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


Introduction

8
7
2

6
5

3
4

15
14

18

22

16

19
17

7
21
NSE0_02087b

5
9

8
20

Siemens LV 10.1 2011

2/5

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Introduction

Benefits
The compact design of the SENTRON 3VL circuit breakers
coupled with excellent characteristics fulfills the high demands of today's electrical distribution systems.
These circuit breakers offer a broad product range, improved
technology, space savings and easy operation.
They are available both in thermal-magnetic (16 A to 630 A)
and in electronic versions (63 A to 1600 A).
Communication
The use of modern communication-capable circuit breakers
opens up completely new possibilities in terms of start-up, parameterization, diagnostics, maintenance and operation. This allows many different ways of reducing costs and improving productivity in industrial plants, buildings and infrastructure projects
to be achieved:
Fast and reliable parameterization
Timely information and response can prevent plant
stoppages
Effective diagnostics management
Measured values are the basis for efficient load management,
for drawing up power demand profiles and for assigning power
to cost centers.
Communication:
For molded case circuit breakers with communication function
see pages 2/12 to 2/28 and 2/40 to 2/50.
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

Applications
The different versions of SENTRON 3VL circuit breakers are suitable for the following applications:
Incoming and outgoing circuit breakers in distribution systems
Switching and protection devices for motors, transformers
and capacitors
Disconnector units with features for stopping and switching off
in an emergency (main control switches and EMERGENCYSTOP switches) in conjunction with lockable rotary operating
mechanisms and terminal covers.
The SENTRON 3VL circuit breakers are available in the following
versions:
1. For system protection (in 3- and 4-pole versions)
The overload and short-circuit releases are designed for the
protection of cables, leads and non-motor loads.
2. For motor protection (in 3-pole version)
The overload and short-circuit releases are designed for optimized protection and direct-on-line starting of induction squirrel-cage motors. The circuit breakers for motor protection are
susceptible to phase failure and feature an adjustable trip
class. The electronic releases operate with a microprocessor.

2/6

Siemens LV 10.1 2011

3. For starter combinations (in 3-pole version)


These circuit breakers are used both for short-circuit protection as well as for isolating functions, which may be required
in starter combinations consisting of circuit breakers, overload
relays and motor contactors. These circuit breakers exclusively feature adjustable, instantaneous short-circuit releases.
4. As non-automatic circuit breakers (in 3- and 4-pole versions)
These circuit breakers can be used as feeder circuit breakers,
main control switches or non-automatic circuit breakers without overload protection. They incorporate an integrated shortcircuit self-protection system, eliminating the need for backup fuses.
Switching capacity
N

Circuit breakers with standard switching capacity N


(Icu up to 55 kA at 415 V)

Circuit breakers with high switching capacity H


(Icu up to 70 kA at 415 V)

Circuit breakers with very high switching capacity L


(Icu up to 100 kA at 415 V)
These switching capacities are indicated in the corresponding tables by the symbols shown on orange backgrounds.

Standards and specifications


SENTRON 3VL circuit breakers comply with:
IEC 60947-1, EN 60947-1,
IEC 60947-2, EN 60947-2.
Isolating features according to IEC 60947-2, EN 60947-2.
Disconnecting features (main control switches) according to
EN 60204.
The SENTRON 3VL circuit breakers comply in addition with requirements for "disconnector units with features for stopping and
switching off in an emergency" (EMERGENCY-STOP switches) in
conjunction with lockable rotary operating mechanisms (red-yellow) and terminal covers.
Please contact Siemens for details of other standards.
The electronic releases of the circuit breakers for motor
protection also fulfill IEC 60947-4-1, EN 60947-2.
VL160X to VL400 circuit breakers can be equipped with a
SENTRON 3VL RCD module. They then comply with
IEC 60947-2 Appendix B.
The SENTRON 3VL RCD module complies with IEC 61000-4-2 to
IEC 61000-4-6, IEC 61000-4-11 and EN 55011, Class B (equivalent to CISPR 11) with regard to electromagnetic compatibility.
Operating conditions
The SENTRON 3VL circuit breakers are designed for operation
in enclosed areas.
Suitable enclosures must be provided for operation in areas with
severe ambient conditions (such as dust, caustic vapors, hazardous gases).

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Introduction
RCD modules
The RCD module is designed for retrofitting to the circuit breaker.
It can also be retrofitted by the customer.

Protection of plant and equipment against overload or damage


by ground faults (ground-fault protection).

The combination of SENTRON 3VL circuit breaker and RCD


module can be fed from the top or bottom.

The RCD module trips the circuit breaker through vectorial summation current formation for all phase currents if the vectorial
sum of the currents in the poles (= the ground fault current) overshoots the pre-set response and delay time values. AC currents
and pulsating DC currents are measured (CBR, design A
according to EN 60947-2).

All SENTRON 3VL circuit breakers with RCD modules are available with auxiliary switches, alarm switches, undervoltage and
shunt releases.
Main connections, basic equipment and options

NSE0_00702

NSE0_00701
NSE0_00700

NSE0_01541

Box terminal
(for copper cables or solid/
flexible busbars)

Connection with screw terminal


(available with direct cable lug connection on VL160X, VL160, VL250, VL400)

Connection to front busbar connecting


bars (screw terminal required)

Circular conductor terminals


multiple feed-in terminal
(for Al/Cu terminal)

Main connections (see below for conductor cross-sections)


Circuit breaker

Connection overview and further options


Box terminals

Screw terminals
Circular conductor
with metric thread for flat terminal/multiple feed-in
connectors
terminals

Rear
terminals

Front-accessible
connecting bars

VL160X
VL160

VL250
VL400
VL630
VL800
VL1250

1)
---

2)3)
2)
2)
2)

VL1600

--

--

- Scope of supply
@ Optional scope of supply
Available
-- Not available

1)

Connecting terminal plate for flexible busbar; not for 690 V AC/600 V DC.

2)

Multiple feed-in terminal

3)

Circular conductor terminal also available.

Conductor cross-sections
Type

VL160X
3VL1

VL160
3VL2

VL250
3VL3

VL400
3VL4

VL630
3VL5

VL800
3VL6

VL1250
3VL7

VL1600
3VL8

2.5 ... 95
2.5 ... 50
12 10

25 ... 185
25 ... 120
17 10

50 ... 300
50 ... 240
25 10

----

----

----

----

--

2 units
10 32

--

--

--

Conductor cross-sections
Box terminals1)
Solid or stranded cable
Finely stranded with end sleeve
Flexible busbar

Copper only mm2 2.5 ... 95


mm2 2.5 ... 50
mm 12 10

Connecting terminal plate for flexible busbar2)

mm --

--

--

Circular conductor terminal for cable1)


Solid or stranded cable
Cu or Al
- With terminal cover
Cu or Al
Finely stranded with end sleeve

mm2 16 ... 70
mm2 16 ... 150
mm2 10 ... 50

16 ... 70
16 ... 150
10 ... 50

25 ... 185
50 ... 300
120 ... 240 -25 ... 120
50 ... 240

----

----

----

----

Multiple feed-in terminal1)


Solid or stranded cable

Cu or Al

mm2 --

--

--

Cu or Al

--

--

--

2 units
50 ... 240
--

3 units
50 ... 240
--

4 units
50 ... 240
--

Finely stranded with end sleeve

mm --

--

--

2 units
50 ... 120
2 units
70 ... 300
2 units
50 ... 95

--

mm2

2 units
50 ... 185

3 units
50 ... 185

4 units
50 ... 185

--

Direct connection of busbars


Cu or Al
Screw for connection with screw terminal

mm 17 7
M6

22 7
M6

24 7
M8

32 10
M8

40 10
M6

2 40 10 2 50 10 3 60 10
M8
M8
--

- With terminal cover

--

Conductor cross-sections for control circuits with


terminal connection
Screw terminals
Solid
Finely stranded with end sleeve
For details see Mounting Instruction.
1)

Cross-sections according to IEC 60999.

2)

Not for 690 V AC/600 V DC.

mm2 0.75 ... 1.5 0.75 ... 1.5 0.75 ... 1.5 0.75 ... 1.5 0.75 ... 1.5 0.75 ... 1.5 0.75 ... 1.5 0.75 ... 1.5
mm2 0.75 ... 1.0 0.75 ... 1.0 0.75 ... 1.0 0.75 ... 1.0 0.75 ... 1.0 0.75 ... 1.0 0.75 ... 1.0 0.75 ... 1.0

Siemens LV 10.1 2011

2/7

Siemens AG 2011

Molded Case Circuit Breakers


Introduction

Releases

System protection

System/generator protection

Motor protection

Starter protection

Non-automatic
circuit breakers

Function

VL160 to VL1600 electronic releases Functional overview

Ir = In

Isd = Ir tsd [s]

Ii = In

Ig = In

tg [s]

---

---

---

--

I
I

---

---

---

7 ... 15

DE

M
M

8 ... 18

---

---

EE

--

--

--

--

--

--

--

8 ... 18

--

--

DA

TM 2)

--

--

--

--

LI

--

--

9 ... 184)

--

--

DD

TM 2)

--

--

--

--

LI

0.8 ... 1

--

--

9 ... 184)

--

--

DC

TM 2)

---

---

---

LI
LI

0.8 ... 1
1

---

---

---

---

EJ

TM 2)
TM 2)

---

5 ... 10

EH

--

--

--

--

LI

0.8 ... 1

--

--

EA

TM 2)

--

--

--

--

LIN

--

--

EC
EM
SP
MP
SB
MB
LB
TA
NA
LA
TB
NB
SL
ML
SF
MF
TN
NN
SE
ME
LE
TE
NE
TF
NF
LF
SG

TM 2)

--

--

--

--

LIN

0.8 ... 1

--

TM 2)
ETU10M3)
ETU10M3)
ETU10
ETU10
ETU10
ETU10
ETU10
ETU10
ETU10
ETU10
ETU12
ETU12
ETU12
ETU12
ETU12
ETU12
ETU20
ETU20
ETU20
ETU20
ETU20
ETU20
ETU20
ETU20
ETU22

--

----------

-----------------

---------------------------

---------------------------

LIN
LI
LI
LI
LI
LI
LIN
LIN
LIN
LI
LI
LIG
LIG
LIG
LIG
LING
LING
LSI
LSI
LSI
LSI
LSI
LSIN
LSIN
LSIN
LSIG

0.8 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1

MG
SH
MH
TH
NH
SS
MS
LS
CP
CH
CJ

ETU22
ETU22
ETU22
ETU22
ETU22
ETU30M3)
ETU30M3)
ETU30M3)
LCD ETU40M3)
LCD ETU40
LCD ETU40

------------

----

----------------------------

---

------------

------------

CL
CM
CN

LCD ETU42
LCD ETU42
LCD ETU42

----

----

----

----

LSIG
LSIG
LSIG
LSING
LSING
LI
LI
LI
LI
LI, LS, LSI
LI, LSI, LIN,
LSIN
LSIG
LSIG
LSIG, LSING

Order No.
supplement

3VL Molded Case Circuit Breakers up to 1600 A

DK

Function is available.
-- Function not available
1)

Size dependent.

2)

TM up to In = 630 A.

3)

Motor protection up to In = 500 A.

4)

Non-adjustable.

2/8

Siemens LV 10.1 2011

Setting options
L

S1)

I1)

Overload
protection

Short-circuit
protection (shorttime delayed)

Short-circuit
protection (instantaneous)

Ground-fault protection

9 ... 184)
5 ... 10

--

--

--

--

--

9 ... 184)
5 ... 10

--

--

-----------------1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10

-----------------0 ... 0.5


0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5

5 ... 10
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
1.25 ... 11
11
11
11
11
11
11
11
11
11

-----------0.6 ... 1, OFF


0.6 ... 1, OFF
0.6 ... 1, OFF
0.6 ... 1, OFF
0.6 ... 1, OFF
0.6 ... 1, OFF
--------0.6 ... 1, OFF

-----------0.1 ... 0.3


0.1 ... 0.3
0.1 ... 0.3
0.1 ... 0.3
0.1 ... 0.3
0.1 ... 0.3
--------0.1 ... 0.3

0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1
0.4 ... 1

1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
1.5 ... 10
----1.5 ... 10
1.5 ... 10

0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5
0 ... 0.5
----0 ... 0.5
0 ... 0.5

11
11
11
11
11
6/8/11
6/8/11
6/8/11
1.25 ... 11
1.25 ... 11
1.25 ... 11

0.6 ... 1, OFF


0.6 ... 1, OFF
0.6 ... 1, OFF
0.6 ... 1, OFF
0.6 ... 1, OFF
-------

0.1 ... 0.3


0.1 ... 0.3
0.1 ... 0.3
0.1 ... 0.3
0.1 ... 0.3
-------

0.4 ... 1
0.4 ... 1
0.4 ... 1

1.5 ... 10 0 ... 0.5


1.5 ... 10 0 ... 0.5
1.5 ... 10 0 ... 0.5

1.25 ... 11
1.25 ... 11
1.25 ... 11

0.4 ... 1
0.4 ... 1
0.4 ... 1

0.1 ... 0.5


0.1 ... 0.5
0.1 ... 0.5

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A

Thermal image

Phase failure

Communication-capable

Ground-fault protection

Number of poles

N pole protected1)

I2t (ON/OFF)

Trip class (tC)

Time-lag class (tR)

Thermal-magnetic releases

Magnetic
releases

Electronic release

LCD display

DE

M
M

---

---

---

---

3
3

---

---

---

---

---

---

---

EE

--

--

--

--

--

--

--

--

--

--

--

DA

TM 2)

--

--

--

--

--

--

--

--

--

--

DD

TM 2)
TM 2)

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

--

---

--

EJ

TM 2)
TM 2)

--

--

--

--

--

--

EA

TM 2)

--

--

--

--

--

--

--

---

--

---

--

TM 2)

---

EC
EM
SP
MP
SB
MB
LB
TA
NA
LA
TB
NB
SL
ML
SF
MF
TN
NN
SE
ME
LE
TE
NE
TF
NF
LF
SG
MG
SH
MH
TH
NH
SS
MS
LS
CP
CH
CJ

100 %
60 %

--

--

--

TM 2)
ETU10M3)
ETU10M3)
ETU10
ETU10
ETU10
ETU10
ETU10
ETU10
ETU10
ETU10
ETU12
ETU12
ETU12
ETU12
ETU12
ETU12
ETU20
ETU20
ETU20
ETU20
ETU20
ETU20
ETU20
ETU20
ETU22
ETU22
ETU22
ETU22
ETU22
ETU22
ETU30M3)
ETU30M3)
ETU30M3)
LCD ETU40M3)
LCD ETU40
LCD ETU40

-40 % IR
40 % IR
----------------------------40 % IR
40 % IR
40 % IR
5 ... 50 % IR
---

--4)
-4)
--4)
--4)
-4)
-4)
-4)
-4)
--4)
-4)
--4)
-4)
-4)
-4)
-----

-----------$
$
%
%
%
%
--------$
$
%
%
%
%
-------

4
3
3
3
3
3
4
4
4
4
4
3
3
3
3
4
4
3
3
3
4
4
4
4
4
3
3
3
3
4
4
3
3
3
3
3
4

100 %
-----50/100 %
50/100 %
50/100 %
------50/100 %
50/100 %
-----50/100 %
50/100 %
50/100 %
----50/100 %
50/100 %
-----50 ... 100 %, OFF

-----------------

----

-10
10
----------------------------10, 20, 30
10, 20, 30
10, 20, 30
5, 10, 15, 20, 30
---

---2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
2.5 ... 30
------------------2.5 ... 30
2.5 ... 30

-------------------------------------

--------------------------------------

----------------------------------

CL
CM

LCD ETU42
LCD ETU42

---

---

3
3

---

---

2.5 ... 30
2.5 ... 30

---

---

CN

LCD ETU42

--

--

50 ... 100 %, OFF

--

2.5 ... 30

--

--

Order No.
supplement

Releases

Introduction

DK

DC
EH

$/&
%

Ground-fault protection
$ Vectorial summation current formation (3-conductor system)
% Vectorial summation current formation (4-conductor system)
& Direct detection of ground-fault current in the neutral point
of the transformer

1)

Size dependent.

2)

TM up to In = 630 A.

3)

Motor protection up to In = 500 A.

4)

With COM20/COM21.

Function is available.
-- Function not available

Siemens LV 10.1 2011

2/9

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole

Selection and ordering data


Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of the DT


**
instantaneous
short-circuit releases "I"
Ii

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

N
PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection, 16 A to 160 A,


thermal-magnetic releases LI
NSE0_00539a
OFF
TM ~
=
50 C
CAT.A

63A

NSE0_00695

System protection, TM, LI function


With non-adjustable thermal overcurrent releases, non-adjustable short-circuit releases
3VL17 96-1DA3@-....
16
16
300
B
3VL17 02-1DA3@-....
VL160X/
20
20
300
B
3VL1
25
25
300
B
3VL17 25-1DA3@-....
3VL17 03-1DA3@-....
32
32
300
B
3VL17 04-1DA3@-....
40
40
600
B
50
50
600
B
3VL17 05-1DA3@-....
63
80
100
125
160

63
80
100
125
160

600
1000
1000
1000
1500

B
B
B
B
B

1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113
113

1.900
1.900
2.000
2.000
2.000
2.000
2.000

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.000
2.000
2.000
2.000

3VL17 02-1DD3@-....
3VL17 03-1DD3@-....
3VL17 04-1DD3@-....
3VL17 05-1DD3@-....
3VL17 06-1DD3@-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

1.900
2.000
2.000
2.000
2.000

3VL17 08-1DD3@-....
3VL17 10-1DD3@-....
3VL17 12-1DD3@-....
3VL17 16-1DD3@-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.000
2.000
2.000
2.000

3VL17 06-1DA3@-....
3VL17 08-1DA3@-....
3VL17 10-1DA3@-....
3VL17 12-1DA3@-....
3VL17 16-1DA3@-....

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal not in conjunction with RCD module
6
NSE0_00540a
OFF
TM ~
=
50 C
CAT.A

63A
1.0
xI n

.8
IR

NSE0_00703

System protection, TM, LI function


With adjustable thermal overcurrent releases, non-adjustable short-circuit releases
VL160X/
20
16 ... 20
300
B
3VL1
32
25 ... 32
300
B
40
32 ... 40
600
B
50
40 ... 50
600
B
63
50 ... 63
600
B
80
100
125
160

63 ... 80
80 ... 100
100 ... 125
125 ... 160

1000
1000
1000
1500

B
B
B
B

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal not in conjunction with RCD module
6

** Delivery time class A for Order No. supplement "0AA0", see page 2/57.

* You can order this quantity or a multiple thereof.

2/10

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole

DT Icu up to 70 kA at 415 V,
** high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT
**

H
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

B
B
B
B
B
B

3VL17 96-2DA3@-....
3VL17 02-2DA3@-....
3VL17 25-2DA3@-....
3VL17 03-2DA3@-....
3VL17 04-2DA3@-....
3VL17 05-2DA3@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

1.900
1.900
2.000
2.000
2.000
2.000

-------

B
B
B
B
B

3VL17 06-2DA3@-....
3VL17 08-2DA3@-....
3VL17 10-2DA3@-....
3VL17 12-2DA3@-....
3VL17 16-2DA3@-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

2.000
2.000
2.000
2.000
2.000

------

>

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3
6

B
B
B
B
B

3VL17 02-2DD3@-....
3VL17 03-2DD3@-....
3VL17 04-2DD3@-....
3VL17 05-2DD3@-....
3VL17 06-2DD3@-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

1.900
2.000
2.000
2.000
2.000

------

B
B
B
B

3VL17 08-2DD3@-....
3VL17 10-2DD3@-....
3VL17 12-2DD3@-....
3VL17 16-2DD3@-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.000
2.000
2.000
2.000

-----

>
3
6

** Delivery time class A for Order No. supplement "0AA0", see page 2/57.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/11

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of the DT


instantaneous
short-circuit releases "I"
Ii

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.

Basic price
PU
per PU (UNIT,
See also SET, M)
page 2/32

PS*/
P. unit

3VL27 05-1DC3@-....
3VL27 06-1DC3@-....
3VL27 08-1DC3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200
2.200
2.200

Order No. supplement


required,
see page 2/57

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection, 50 A to 630 A,


thermal-magnetic releases LI
NSE0_-00541a
I

Ii

7
6

I n =160A

L
5

16 DC
1.0

50 C

I I
R i
~
TM = CAT.A

9 xI
n

xI n

10

.8

NSE0_00691

System protection, TM, LI function


With adjustable thermal overcurrent releases, adjustable short-circuit releases
VL160/
50
40 ... 50
300 ... 600
B
3VL2
63
50 ... 63
300 ... 600
B
80
63 ... 80
400 ... 800
B

VL250/
3VL3

100
125
160

80 ... 100
100 ... 125
125 ... 160

500 ... 1000


625 ... 1250
800 ... 1600

B
B
B

3VL27 10-1DC3@-....
3VL27 12-1DC3@-....
3VL27 16-1DC3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200
2.200
2.200

200
250

160 ... 200


200 ... 250

1000 ... 2000


1250 ... 2500

B
B

3VL37 20-1DC3@-....
3VL37 25-1DC3@-....

1
1

1 unit
1 unit

113
113

2.300
2.300

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

200
250
315
400

160 ... 200


200 ... 250
250 ... 315
320 ... 400

1000 ... 2000


1250 ... 2500
1575 ... 3150
2000 ... 4000

B
B
B
B

3VL47 20-1DC36-....
3VL47 25-1DC36-....
3VL47 31-1DC36-....
3VL47 40-1DC36-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

5.700
5.700
5.700
5.700

VL630/3VL5

315
400
500
630

250 ... 315


320 ... 400
400 ... 500
500 ... 630

1575 ... 3150


2000 ... 4000
2500 ... 5000
3150 ... 6300

B
B
B
B

3VL57 31-1DC36-....
3VL57 40-1DC36-....
3VL57 50-1DC36-....
3VL57 63-1DC36-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

9.000
9.000
9.000
9.000

3-pole, fixed-mounted, for system protection, 63 A to 1600 A,


electronic releases LI
NSE0_02119

I R 1.0 .4
.95

.9
X3

.45

t R (S) 30 2.5

.5

.8
.6
x I n .7 .63

25

4
6

20

17
14 10

Ii
10

Alarm
>1.05

11 1.25
1.5
2

8
6
xI n 5

Active

3
4

NSE0_00691

ETU10, LI function
With adjustable overcurrent releases, adjustable short-circuit releases
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
100
40 ... 100
1.25 ... 11 In
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

B
B
B

3VL27 06-1@@3@-....
3VL27 10-1@@3@-....
3VL27 16-1@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
B
B

3VL47 31-1@@36-....
3VL47 40-1@@36-....

1
1

1 unit
1 unit

113
113

1.25 ... 10 In

3VL57 63-1@@36-....

1 unit

113

9.300

1.25 ... 8 In

3VL67 80-1@@36-....

1 unit

113

16.000

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL77 10-1@@36-....
3VL77 12-1@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

640 ... 1600

1.25 ... 9 In

3VL87 16-1@@30-....

1 unit

113

31.300

VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

VL630/3VL5

630

525 ... 630

VL800/3VL6

800

320 ... 800

VL1250/3VL7

1000
1250

VL1600/3VL81)

1600

1)

>

Without communication preparation


SB
With communication preparation
MB
Marine engineering-certified LRS, DNV and GL (not communication-ready) LB

Front busbar connection pieces are included in the scope of supply and
are to be fitted by the customer.

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".
* You can order this quantity or a multiple thereof.

2/12

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
Basic price
PU
per PU (UNIT,
See also SET, M)
page 2/32

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.

kg

Order No. supplement


required,
see page 2/57

Basic price
PU
per PU (UNIT,
See also SET, M)
page 2/32

PS*/
P. unit

PG Weight
per PU
approx.
kg

B
B
B

3VL27 05-2DC3@-....
3VL27 06-2DC3@-....
3VL27 08-2DC3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200 B
2.200 B
2.200 B

3VL27 05-3DC3@-....
3VL27 06-3DC3@-....
3VL27 08-3DC3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200
2.200
2.200

B
B
B

3VL27 10-2DC3@-....
3VL27 12-2DC3@-....
3VL27 16-2DC3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200 B
2.200 B
2.200 B

3VL27 10-3DC3@-....
3VL27 12-3DC3@-....
3VL27 16-3DC3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200
2.200
2.200

B
B

3VL37 20-2DC3@-....
3VL37 25-2DC3@-....

1
1

1 unit
1 unit

113
113

2.300 B
2.300 B

3VL37 20-3DC3@-....
3VL37 25-3DC3@-....

1
1

1 unit
1 unit

113
113

2.300
2.300

>
3
6

>
3
6

B
B
B
B

3VL47 20-2DC36-....
3VL47 25-2DC36-....
3VL47 31-2DC36-....
3VL47 40-2DC36-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

5.700
5.700
5.700
5.700

B
B
B
B

3VL47 20-3DC36-....
3VL47 25-3DC36-....
3VL47 31-3DC36-....
3VL47 40-3DC36-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

5.700
5.700
5.700
5.700

B
B
B
B

3VL57 31-2DC36-....
3VL57 40-2DC36-....
3VL57 50-2DC36-....
3VL57 63-2DC36-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

9.000
9.000
9.000
9.000

B
B
B
B

3VL57 31-3DC36-....
3VL57 40-3DC36-....
3VL57 50-3DC36-....
3VL57 63-3DC36-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

9.000
9.000
9.000
9.000

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

>

3
6

3
6

B
B

3VL47 31-2@@36-....
3VL47 40-2@@36-....

1
1

3VL57 63-2@@36-....

1 unit

3VL67 80-2@@36-....

1 unit

B
B

3VL77 10-2@@36-....
3VL77 12-2@@36-....

1
1

1 unit
1 unit

3VL87 16-2@@30-....

1 unit

>
SB
MB
LB

1 unit
1 unit

113
113

5.900 B
5.900 B

3VL47 31-3@@36-....
3VL47 40-3@@36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3@@36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3@@36-....

1 unit

113

16.000

113
113

25.000 B
25.000 B

3VL77 10-3@@36-....
3VL77 12-3@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

113

31.300 B

3VL87 16-3@@30-....

1 unit

113

31.300

>
SB
MB
LB

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/13

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated Current
current setting of the
In
inverse-time
delayed
overcurrent
releases "L"
IR

Operating
current of the
instantaneous
short-circuit
releases "I"
Ii

Ground-fault
protection "G"
Ig

DT

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.

For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

N
PG Weight
per PU
approx.

Order No. supplement


required,
see page 2/57

kg

3-pole, fixed-mounted, for system protection, 63 A to 1600 A,


electronic releases LIG
NSE0_02118

I R 1.0 .4
.95

.9
X3

.45
.5

.8

x I n .7 .63

.6

t R (S) 30 2.5
25

4
6

20

17
14 10

Alarm
Ig I t g OFF .6/.1
11 1.25
>1.05
1.5
1/.3
1/.1
.6/.3
2 .6/.3
8
Active
1/.3
1/.1
6
3
.6/.1 OFF
xI n 5 4

Ii

10

NSE0_00693

ETU12, LIG function for 3-wire three-phase systems


With adjustable overcurrent releases, adjustable short-circuit releases,
vectorial summation current, ground fault delay tg = 0.1 ... 0.3 s, ground fault function (G) can be switched off.
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
0.6 ... 1 In, OFF B
3VL27 06-1@@3@-....
0.6 ... 1 In, OFF B
3VL27 10-1@@3@-....
100
40 ... 100
1.25 ... 11 In
0.6 ... 1 In, OFF B
3VL27 16-1@@3@-....
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

VL630/3VL5

630

252 ... 630

VL800/3VL6

800

320 ... 800

VL1250/3VL7

1000
1250

VL1600/3VL81)

1600

0.6 ... 1 In, OFF B


0.6 ... 1 In, OFF B

3VL47 31-1@@36-....
3VL47 40-1@@36-....

1
1

1 unit
1 unit

113
113

1.25 ... 10 In

0.6 ... 1 In, OFF

3VL57 63-1@@36-....

1 unit

113

9.300

1.25 ... 8 In

0.6 ... 1 In, OFF

3VL67 80-1@@36-....

1 unit

113

16.000

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL77 10-1@@36-....
3VL77 12-1@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

640 ... 1600

1.25 ... 9 In

0.6 ... 1 In, OFF

3VL87 16-1@@30-....

1 unit

113

31.300

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

Without communication preparation


With communication preparation

SL
ML

3-pole, fixed-mounted, for system protection, 63 A to 1600 A,


electronic releases LIG
NSE0_02118

I R 1.0 .4
.95

L
X3

.45

.9

.5

.8
.6
x I n .7 .63

t R (S) 30 2.5
25

Alarm
Ig I t g OFF .6/.1
11 1.25
>1.05
1.5
10
1/.3
1/.1
.6/.3
2 .6/.3
8

Ii

20

17
14 10

6
xI n 5

3
4

1/.3
1/.1
.6/.1 OFF

Active

NSE0_00693

ETU12, LIG function for 4-wire three-phase systems


With adjustable overcurrent releases, adjustable short-circuit releases,
vectorial summation current, external current transformers required in addition, see page 2/90.
Ground fault delay tg = 0.1 ... 0.3 s, ground fault function (G) can be switched off.
0.6 ... 1 In, OFF B
3VL27 06-1@@3@-....
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
0.6 ... 1 In, OFF B
3VL27 10-1@@3@-....
100
40 ... 100
1.25 ... 11 In
0.6 ... 1 In, OFF B
3VL27 16-1@@3@-....
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

VL630/3VL5

630

252 ... 630

VL800/3VL6

800

320 ... 800

VL1250/3VL7

1000
1250

VL1600/3VL81)

1600

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL47 31-1@@36-....
3VL47 40-1@@36-....

1
1

1 unit
1 unit

113
113

1.25 ... 10 In

0.6 ... 1 In, OFF

3VL57 63-1@@36-....

1 unit

113

9.300

1.25 ... 8 In

0.6 ... 1 In, OFF

3VL67 80-1@@36-....

1 unit

113

16.000

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL77 10-1@@36-....
3VL77 12-1@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

640 ... 1600

1.25 ... 9 In

0.6 ... 1 In, OFF

3VL87 16-1@@30-....

1 unit

113

31.300

Without communication preparation


With communication preparation
1)

>
SF
MF

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.
* You can order this quantity or a multiple thereof.

2/14

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

>

3
6

3
6

B
B

3VL47 31-2@@36-....
3VL47 40-2@@36-....

1
1

3VL57 63-2@@36-....

1 unit

3VL67 80-2@@36-....

1 unit

B
B

3VL77 10-2@@36-....
3VL77 12-2@@36-....

1
1

1 unit
1 unit

3VL87 16-2@@30-....

1 unit

>

1 unit
1 unit

113
113

5.900 B
5.900 B

3VL47 31-3@@36-....
3VL47 40-3@@36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3@@36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3@@36-....

1 unit

113

16.000

113
113

25.000 B
25.000 B

3VL77 10-3@@36-....
3VL77 12-3@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

113

31.300 B

3VL87 16-3@@30-....

1 unit

113

31.300

SL
ML

>
SL
ML

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

>

3
6

3
6

B
B

3VL47 31-2@@36-....
3VL47 40-2@@36-....

1
1

3VL57 63-2@@36-....

1 unit

3VL67 80-2@@36-....

1 unit

B
B

3VL77 10-2@@36-....
3VL77 12-2@@36-....

1
1

1 unit
1 unit

3VL87 16-2@@30-....

1 unit

>
SF
MF

Communication:
For accessories, see page 2/98.

1 unit
1 unit

113
113

5.900 B
5.900 B

3VL47 31-3@@36-....
3VL47 40-3@@36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3@@36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3@@36-....

1 unit

113

16.000

113
113

25.000 B
25.000 B

3VL77 10-3@@36-....
3VL77 12-3@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

113

31.300 B

3VL87 16-3@@30-....

1 unit

113

31.300

>
SF
MF

For more information see also chapters "Measuring Devices and


E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/15

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current setting of
the inverse-time
delayed
overcurrent
releases "L"
IR

Operating
current of the
instantaneous
short-circuit
releases "I"
Ii

S function DT
shortcircuit
protection
(short-time
delayed)
S

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSI
NSE0_02120

I R 1.0 .4
.95

.45

.9
X3

.5

.8
.6
x I n .7 .63

I sd

10 1.5
8

t sd(S) .4 0
.3

.2

2.5

7
5

.2

.3 I t
3 I t .1
4 x I R ON .5 .4 OFF
2

Alarm
>1.05

.1

Active

NSE0_00692

ETU20, LSI function for time-based discrimination


With adjustable overcurrent releases, non-adjustable short-circuit releases, short-circuit delay (tsd = 0 to 0.5 s)
11 In
1.5 ... 10xIR B
3VL27 06-1@@3@-....
VL160/3VL2
63
0.4 ... 1.0 In
11 In
1.5 ... 10xIR B
3VL27 10-1@@3@-....
100
0.4 ... 1.0 In
160
0.4 ... 1.0 In
11 In
1.5 ... 10xIR B
3VL27 16-1@@3@-....
VL250/3VL3

200
250

0.4 ... 1.0 In


0.4 ... 1.0 In

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

113
113

5.900
5.900

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

0.4 ... 1.0 In


0.4 ... 1.0 In

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL47 31-1@@36-....
3VL47 40-1@@36-....

1
1

1 unit
1 unit

VL630/3VL5

630

0.4 ... 1.0 In

10 In

1.5 ... 9xIR B

3VL57 63-1@@36-....

1 unit

113

9.300

VL800/3VL6

800

0.4 ... 1.0 In

8 In

1.5 ... 7xIR B

3VL67 80-1@@36-....

1 unit

113

16.000

VL1250/3VL7

1000
1250

0.4 ... 1.0 In


0.4 ... 1.0 In

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL77 10-1@@36-....
3VL77 12-1@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

VL1600/3VL81)

1600

0.4 ... 1.0 In

9 In

1.5 ... 8xIR B

3VL87 16-1@@30-....

1 unit

113

31.300

1)

>

Without communication preparation


SE
With communication preparation
ME
Marine engineering-certified LRS, DNV and GL (not communication-ready) LE

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

2/16

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

>

3
6

3
6

B
B

3VL47 31-2@@36-....
3VL47 40-2@@36-....

1
1

1 unit
1 unit

113
113

3VL57 63-2@@36-....

1 unit

3VL67 80-2@@36-....

1 unit

B
B

3VL77 10-2@@36-....
3VL77 12-2@@36-....

1
1

3VL87 16-2@@30-....

>
SE
ME
LE

5.900 B
5.900 B

3VL47 31-3@@36-....
3VL47 40-3@@36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3@@36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3@@36-....

1 unit

113

16.000

1 unit
1 unit

113
113

25.000 B
25.000 B

3VL77 10-3@@36-....
3VL77 12-3@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

1 unit

113

31.300 B

3VL87 16-3@@30-....

1 unit

113

31.300

>
SE
ME
LE

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/17

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current
setting of the
inverse-time
delayed
overcurrent
releases "L"
IR

Operating
current of
the instantaneous
shortcircuit
releases
"I" Ii

S function Ground-fault
protection "G"
shortIg
circuit
protection
(short-time
delayed) S

DT

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement required,
see page 2/57

For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSIG
NSE0_02121

I R 1.0 .4
.95

.9
X3

.45

I sd

.5

.8
.6
x I n .7 .63

10 1.5
8

t sd(S) .4 0
.3

6
5

Ig I t g OFF .6/.1

Alarm
>1.05

1/.3
1/.1
.6/.3
.6/.3
Active
2
2
t
I
t
I
1/.3
.3
.1
1/.1
3
.4
ON
.5
OFF
.6/.1 OFF
4 xI R
2.5

.1

.2

.2

NSE0_00694

ETU22, LSIG function for 3-wire three-phase systems and time-based discrimination
With adjustable overcurrent releases, non-adjustable short-circuit releases,
ground fault delay tg = 0.1 ... 0.3 s, short-circuit delay tsd = 0 ... 0.5 s, ground-fault protection (G) can be switched off
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 06-1@@3@-....
VL160/3VL2
63
25 ... 63
11 In
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 10-1@@3@-....
100
40 ... 100
11 In
160
64 ... 160
11 In
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 16-1@@3@-....
VL250/3VL3

200
250

80 ... 200
100 ... 250

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal
VL400/3VL4

315
400

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

113
113

5.900
5.900

3
6

128 ... 315


160 ... 400

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL47 31-1@@36-....
3VL47 40-1@@36-....

1
1

1 unit
1 unit

VL630/3VL5

630

252 ... 630

10 In

1.5 ... 9xIR 0.6 ... 1 In, OFF B

3VL57 63-1@@36-....

1 unit

113

9.300

VL800/3VL6

800

320 ... 800

8 In

1.5 ... 7xIR 0.6 ... 1 In, OFF B

3VL67 80-1@@36-....

1 unit

113

16.000

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL77 10-1@@36-....
3VL77 12-1@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

VL1600/3VL81) 1600

640 ... 1600

9 In

1.5 ... 8xIR 0.6 ... 1 In, OFF B

3VL87 16-1@@30-....

1 unit

113

31.300

Without communication preparation


With communication preparation
1)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

>
SG
MG

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

2/18

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

>

3
6

3
6

B
B

3VL47 31-2@@36-....
3VL47 40-2@@36-....

1
1

1 unit
1 unit

113
113

3VL57 63-2@@36-....

1 unit

3VL67 80-2@@36-....

1 unit

B
B

3VL77 10-2@@36-....
3VL77 12-2@@36-....

1
1

3VL87 16-2@@30-....

>
SG
MG

5.900 B
5.900 B

3VL47 31-3@@36-....
3VL47 40-3@@36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3@@36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3@@36-....

1 unit

113

16.000

1 unit
1 unit

113
113

25.000 B
25.000 B

3VL77 10-3@@36-....
3VL77 12-3@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

1 unit

113

31.300 B

3VL87 16-3@@30-....

1 unit

113

31.300

>
SG
MG

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/19

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current
setting of the
inverse-time
delayed
overcurrent
releases "L"
IR

Operating
current of
the instantaneous
shortcircuit
releases
"I" Ii

S function Ground-fault
protection "G"
shortIg
circuit
protection
(short-time
delayed) S

DT

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSIG
NSE-00547a

L
ESC

L1=178; L2=181

S
I

L3=179; N=0

NSE0_00697

CAT.A

n=250

25 CL

A~

LCD-ETU42, LSIG function for 3-wire three-phase systems and time-based discrimination
With adjustable overcurrent releases, adjustable short-circuit releases
Vectorial summation current, ground fault delay tg = 0.1 ... 0.5 s, short-circuit delay tsd = 0 ... 0.5 s
1.5 ... 10xIR 0.4 ... 1 In
B
3VL27 06-1CL3@-....
VL160/3VL2
63
25 ... 63
11 In
100
40 ... 100
11 In
1.5 ... 10xIR 0.4 ... 1 In
B
3VL27 10-1CL3@-....
1.5 ... 10xIR 0.4 ... 1 In
B
3VL27 16-1CL3@-....
160
64 ... 160
11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

11 In
11 In

1.5 ... 10xIR 0.4 ... 1 In


1.5 ... 10xIR 0.4 ... 1 In

B
B

3VL37 20-1CL3@-....
3VL37 25-1CL3@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal
VL400/3VL4

315
400

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

113
113

5.900
5.900

3
6

128 ... 315


160 ... 400

11 In
11 In

1.5 ... 10xIR 0.4 ... 1 In


1.5 ... 10xIR 0.4 ... 1 In

B
B

3VL47 31-1CL36-....
3VL47 40-1CL36-....

1
1

1 unit
1 unit

VL630/3VL5

630

252 ... 630

10 In

1.5 ... 9xIR 0.4 ... 1 In

3VL57 63-1CL36-....

1 unit

113

9.300

VL800/3VL6

800

320 ... 800

8 In

1.5 ... 7xIR 0.4 ... 1 In

3VL67 80-1CL36-....

1 unit

113

16.000

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

11 In
11 In

1.5 ... 10xIR 0.4 ... 1 In


1.5 ... 10xIR 0.4 ... 1 In

B
B

3VL77 10-1CL36-....
3VL77 12-1CL36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

VL1600/3VL81) 1600

640 ... 1600

9 In

1.5 ... 8xIR 0.4 ... 1 In

3VL87 16-1CL30-....

1 unit

113

31.300

With adjustable overcurrent releases, adjustable short-circuit releases. External current transformer required in addition, see pages 2/90.
Vectorial summation current, ground fault delay tg = 0.1 ... 0.5 s, short-circuit delay tsd = 0 ... 0.5 s
VL160/3VL2
63
25 ... 63
11 In
1.5 ... 10xIR 0.4 ... 1 In
B
3VL27 06-1CM3@-....
1
1 unit
1.5 ... 10xIR 0.4 ... 1 In
B
3VL27 10-1CM3@-....
1
1 unit
100
40 ... 100
11 In
1.5 ... 10xIR 0.4 ... 1 In
B
3VL27 16-1CM3@-....
1
1 unit
160
64 ... 160
11 In

113
113
113

2.400
2.400
2.400

NSE-00547a

L
ESC

L1=178; L2=181

S
I

L3=179; N=0

NSE0_00697

CAT.A

n=250

25 CL

A~

LCD-ETU42, LSIG function for 4-wire three-phase systems and time-based discrimination

VL250/3VL3

200
250

80 ... 200
100 ... 250

11 In
11 In

1.5 ... 10xIR 0.4 ... 1 In


1.5 ... 10xIR 0.4 ... 1 In

B
B

3VL37 20-1CM3@-....
3VL37 25-1CM3@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal
VL400/3VL4

315
400

>

1
1

1 unit
1 unit

113
113

2.500
2.500

113
113

5.900
5.900

3
6

128 ... 315


160 ... 400

11 In
11 In

1.5 ... 10xIR 0.4 ... 1 In


1.5 ... 10xIR 0.4 ... 1 In

B
B

3VL47 31-1CM36-....
3VL47 40-1CM36-....

1
1

1 unit
1 unit

VL630/3VL5

630

252 ... 630

10 In

1.5 ... 9xIR 0.4 ... 1 In

3VL57 63-1CM36-....

1 unit

113

9.300

VL800/3VL6

800

320 ... 800

8 In

1.5 ... 7xIR 0.4 ... 1 In

3VL67 80-1CM36-....

1 unit

113

16.000

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

11 In
11 In

1.5 ... 10xIR 0.4 ... 1 In


1.5 ... 10xIR 0.4 ... 1 In

B
B

3VL77 10-1CM36-....
3VL77 12-1CM36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

VL1600/3VL81) 1600

640 ... 1600

9 In

1.5 ... 8xIR 0.4 ... 1 In

3VL87 16-1CM30-....

1 unit

113

31.300

1)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

* You can order this quantity or a multiple thereof.

2/20

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2CL3@-....
3VL27 10-2CL3@-....
3VL27 16-2CL3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3CL3@-....
3VL27 10-3CL3@-....
3VL27 16-3CL3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2CL3@-....
3VL37 25-2CL3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3CL3@-....
3VL37 25-3CL3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>
3
6

>
3
6

B
B

3VL47 31-2CL36-....
3VL47 40-2CL36-....

1
1

1 unit
1 unit

113
113

3VL57 63-2CL36-....

1 unit

3VL67 80-2CL36-....

1 unit

B
B

3VL77 10-2CL36-....
3VL77 12-2CL36-....

1
1

3VL87 16-2CL30-....

B
B
B
B
B

5.900 B
5.900 B

3VL47 31-3CL36-....
3VL47 40-3CL36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3CL36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3CL36-....

1 unit

113

16.000

1 unit
1 unit

113
113

25.000 B
25.000 B

3VL77 10-3CL36-....
3VL77 12-3CL36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

1 unit

113

31.300 B

3VL87 16-3CL30-....

1 unit

113

31.300

3VL27 06-2CM3@-....
3VL27 10-2CM3@-....
3VL27 16-2CM3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3CM3@-....
3VL27 10-3CM3@-....
3VL27 16-3CM3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

3VL37 20-2CM3@-....
3VL37 25-2CM3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3CM3@-....
3VL37 25-3CM3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>
3
6

>
3
6

B
B

3VL47 31-2CM36-....
3VL47 40-2CM36-....

1
1

1 unit
1 unit

113
113

3VL57 63-2CM36-....

1 unit

3VL67 80-2CM36-....

1 unit

B
B

3VL77 10-2CM36-....
3VL77 12-2CM36-....

1
1

3VL87 16-2CM30-....

5.900 B
5.900 B

3VL47 31-3CM36-....
3VL47 40-3CM36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3CM36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3CM36-....

1 unit

113

16.000

1 unit
1 unit

113
113

25.000 B
25.000 B

3VL77 10-3CM36-....
3VL77 12-3CM36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

1 unit

113

31.300 B

3VL87 16-3CM30-....

1 unit

113

31.300

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/21

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current
setting of the
inverse-time
delayed
overcurrent
releases
"L"
IR

Operating
current of
the instantaneous
shortcircuit
releases
"I" Ii

S function Ground-fault
protection "G"
shortIg
circuit
protection
(short-time
delayed) S

DT

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement required,
see page 2/57

For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSIG
NSE0_02121

I R 1.0 .4
.95

.9
X3

.45

I sd

.5

.8
.6
x I n .7 .63

10 1.5
8

t sd(S) .4 0
.3

6
5

Ig I t g OFF .6/.1

Alarm
>1.05

1/.3
1/.1
.6/.3
.6/.3
Active
2
2
t
I
t
I
1/.3
.3
.1
1/.1
3
.4
ON
.5
OFF
.6/.1 OFF
4 xI R
2.5

.1

.2

.2

NSE0_00694

ETU22, LSIG function for 4-wire three-phase systems and time-based discrimination
With adjustable overcurrent releases, non-adjustable short-circuit releases, external current transformers required in addition, see page 2/90.
Ground fault delay tg = 0.1 ... 0.3 s, short-circuit delay tsd = 0 ... 0.5 s, ground fault function (G) can be switched off.
VL160/3VL2
63
25 ... 63
11 In
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 06-1@@3@-....
1
1 unit
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 10-1@@3@-....
1
1 unit
100
40 ... 100
11 In
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 16-1@@3@-....
1
1 unit
160
64 ... 160
11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal
VL400/3VL4

315
400

>

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

113
113

5.900
5.900

3
6

128 ... 315


160 ... 400

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL47 31-1@@36-....
3VL47 40-1@@36-....

1
1

1 unit
1 unit

VL630/3VL5

630

252 ... 630

10 In

1.5 ... 9xIR 0.6 ... 1 In, OFF B

3VL57 63-1@@36-....

1 unit

113

9.300

VL800/3VL6

800

320 ... 800

8 In

1.5 ... 7xIR 0.6 ... 1 In, OFF B

3VL67 80-1@@36-....

1 unit

113

16.000

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL77 10-1@@36-....
3VL77 12-1@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

VL1600/3VL81) 1600

640 ... 1600

9 In

1.5 ... 8xIR 0.6 ... 1 In, OFF B

3VL87 16-1@@30-....

1 unit

113

31.300

Without communication preparation


With communication preparation
1)

>
SH
MH

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

2/22

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>

>

3
6

3
6

B
B

3VL47 31-2@@36-....
3VL47 40-2@@36-....

1
1

1 unit
1 unit

113
113

3VL57 63-2@@36-....

1 unit

3VL67 80-2@@36-....

1 unit

B
B

3VL77 10-2@@36-....
3VL77 12-2@@36-....

1
1

3VL87 16-2@@30-....

>
SH
MH

5.900 B
5.900 B

3VL47 31-3@@36-....
3VL47 40-3@@36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3@@36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3@@36-....

1 unit

113

16.000

1 unit
1 unit

113
113

25.000 B
25.000 B

3VL77 10-3@@36-....
3VL77 12-3@@36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

1 unit

113

31.300 B

3VL87 16-3@@30-....

1 unit

113

31.300

>
SH
MH

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/23

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current setting of
the inverse-time
delayed
overcurrent
releases
"L"
IR

Operating
current of the
instantaneous
short-circuit
releases "I"
Ii

S function DT
shortcircuit
protection
(short-time
delayed)
S

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LI, LS, LSI
NSE-00547a

L
ESC

L1=178; L2=181

L3=179; N=0

NSE0_00696

CAT.A

n=250

25 CL

A~

LCD-ETU40, LI/LS/LSI function selectable


With adjustable overcurrent releases, adjustable short-circuit releases, short-circuit delay (tsd = 0 to 0.5 s)
3VL27 06-1CH3@-....
VL160/3VL2
63
25 ... 63
1.25 ... 11 In 1.5 ... 10xIR B
3VL27 10-1CH3@-....
100
40 ... 100
1.25 ... 11 In 1.5 ... 10xIR B
160
64 ... 160
1.25 ... 11 In 1.5 ... 10xIR B
3VL27 16-1CH3@-....
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL37 20-1CH3@-....
3VL37 25-1CH3@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

113
113

5.900
5.900

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL47 31-1CH36-....
3VL47 40-1CH36-....

1
1

1 unit
1 unit

VL630/3VL5

630

252 ... 630

1.25 ... 10 In

1.5 ... 9xIR B

3VL57 63-1CH36-....

1 unit

113

9.300

VL800/3VL6

800

320 ... 800

1.25 ... 8 In

1.5 ... 7xIR B

3VL67 80-1CH36-....

1 unit

113

16.000

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL77 10-1CH36-....
3VL77 12-1CH36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

VL1600/3VL81)

1600

640 ... 1600

1.25 ... 9 In

1.5 ... 8xIR B

3VL87 16-1CH30-....

1 unit

113

31.300

1)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

* You can order this quantity or a multiple thereof.

2/24

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2CH3@-....
3VL27 10-2CH3@-....
3VL27 16-2CH3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3CH3@-....
3VL27 10-3CH3@-....
3VL27 16-3CH3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2CH3@-....
3VL37 25-2CH3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3CH3@-....
3VL37 25-3CH3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

5.900
5.900

>
3
6

>
3
6

B
B

3VL47 31-2CH36-....
3VL47 40-2CH36-....

1
1

1 unit
1 unit

113
113

3VL57 63-2CH36-....

1 unit

3VL67 80-2CH36-....

1 unit

B
B

3VL77 10-2CH36-....
3VL77 12-2CH36-....

1
1

3VL87 16-2CH30-....

5.900 B
5.900 B

3VL47 31-3CH36-....
3VL47 40-3CH36-....

1
1

1 unit
1 unit

113
113

113

9.300 B

3VL57 63-3CH36-....

1 unit

113

9.300

113

16.000 B

3VL67 80-3CH36-....

1 unit

113

16.000

1 unit
1 unit

113
113

25.000 B
25.000 B

3VL77 10-3CH36-....
3VL77 12-3CH36-....

1
1

1 unit
1 unit

113
113

25.000
25.000

1 unit

113

31.300 B

3VL87 16-3CH30-....

1 unit

113

31.300

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/25

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of DT
the instantaneous
short-circuit releases
"I"
Ii

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

For price
PU
see page (UNIT,
2/32 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for motor protection,


63 A to 500 A, electronic releases LI
NSE0_02081

L
.4 .4
.4

.4

X3

.10 .01
.09

.5 + .08

.4

IR

.6

.9
.8 .7

xI n

.02
.03

.04
.07
.06 .05

Ii

Alarm

11 1.25
1.5
10

xI n

>1.05

8
6

Active

3
5

NSE0_00943

ETU10M, LI function
With thermal image, with non-adjustable trip class tC = 10, with phase failure sensitivity 40 % IR
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
B
3VL27 06-1@@3@-....
100
40 ... 100
1.25 ... 11 In
B
3VL27 10-1@@3@-....
B
3VL27 16-1@@3@-....
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315

125 ... 315

1.25 ... 11 In

3VL47 31-1@@36-....

1 unit

113

5.900

VL630/3VL5

500

200 ... 500

1.25 ... 12.5 In

3VL57 50-1@@36-....

1 unit

113

9.300

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

>

Without communication preparation


With communication preparation

SP
MP

NSE0_02082

.4 .4
.4

.4

X3

.09

.5 + .08

.4

IR

.6

.9
.8 .7

xI n

.10 .01 Ii =11x In 30 10 TC


.02
20 =6x
20
.03

.04
.07
.06 .05

Ii

10

30

Alarm
>1.05

In

Active

10

Test
30 20

Ii =8x In

NSE0_01419

ETU30M, LI function
With thermal image, with adjustable trip class tC = 10, 20, 30, with phase failure sensitivity 40 % IR
VL160/3VL2
63
25 ... 63
6/8/11 In
B
3VL27 06-1@@3@-....
B
3VL27 10-1@@3@-....
100
40 ... 100
6/8/11 In
160
64 ... 160
6/8/11 In
B
3VL27 16-1@@3@-....
VL250/3VL3

200
250

80 ... 200
100 ... 250

6/8/11 In
6/8/11 In

B
B

3VL37 20-1@@3@-....
3VL37 25-1@@3@-....

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315

125 ... 315

6/8/11 In

3VL47 31-1@@36-....

1 unit

113

5.900

VL630/3VL5

500

200 ... 500

6/8/12.5 In

3VL57 50-1@@36-....

1 unit

113

9.300

>

Without communication preparation


SS
With communication preparation
MS
Marine engineering-certified LRS, DNV and GL (not communication-ready) LS

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

2/26

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/32

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

>

>

3
6

3
6

3VL47 31-2@@36-....

1 unit

113

5.900 B

3VL47 31-3@@36-....

1 unit

113

5.900

3VL57 50-2@@36-....

1 unit

113

9.300 B

3VL57 50-3@@36-....

1 unit

113

9.300

>
SP
MP

>
SP
MP

B
B
B

3VL27 06-2@@3@-....
3VL27 10-2@@3@-....
3VL27 16-2@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3@@3@-....
3VL27 10-3@@3@-....
3VL27 16-3@@3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2@@3@-....
3VL37 25-2@@3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3@@3@-....
3VL37 25-3@@3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

>

>

3
6

3
6

3VL47 31-2@@36-....

1 unit

113

5.900 B

3VL47 31-3@@36-....

1 unit

113

5.900

3VL57 50-2@@36-....

1 unit

113

9.300 B

3VL57 50-3@@36-....

1 unit

113

9.300

>
SS
MS
LS

>
SS
MS
LS

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/27

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of DT
the instantaneous
short-circuit releases
"I"
Ii

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for motor protection,


63 A to 500 A, electronic releases LI
NSE-00547a

L
ESC

L1=178; L2=181

L3=179; N=0

NSE0_01419

CAT.A

n=250

25 CL

A~

LCD-ETU40M, LI function
With thermal image, with adjustable trip class tC = 5, 10, 15, 20, 30, phase failure sensitivity adjustable in steps 5 ... 50 % IR
B
3VL27 06-1CP3@-....
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
B
3VL27 10-1CP3@-....
100
40 ... 100
1.25 ... 11 In
160
64 ... 160
1.25 ... 11 In
B
3VL27 16-1CP3@-....
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL37 20-1CP3@-....
3VL37 25-1CP3@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

1
1

1 unit
1 unit

113
113

2.500
2.500

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315

128 ... 315

1.25 ... 11 In

3VL47 31-1CP36-....

1 unit

113

5.900

VL630/3VL5

500

250 ... 500

1.25 ... 11 In

3VL57 50-1CP36-....

1 unit

113

9.300

* You can order this quantity or a multiple thereof.

2/28

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2CP3@-....
3VL27 10-2CP3@-....
3VL27 16-2CP3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400 B
2.400 B
2.400 B

3VL27 06-3CP3@-....
3VL27 10-3CP3@-....
3VL27 16-3CP3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.400
2.400
2.400

B
B

3VL37 20-2CP3@-....
3VL37 25-2CP3@-....

1
1

1 unit
1 unit

113
113

2.500 B
2.500 B

3VL37 20-3CP3@-....
3VL37 25-3CP3@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

>
3
6

>
3
6

3VL47 31-2CP36-....

1 unit

113

5.900 B

3VL47 31-3CP36-....

1 unit

113

5.900

3VL57 50-2CP36-....

1 unit

113

9.300 B

3VL57 50-3CP36-....

1 unit

113

9.300

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/29

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Type

Rated current
In

Operating current of DT
the instantaneous
short-circuit releases
"I"
Ii

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3-pole, fixed-mounted, for starter protection,


63 A to 500 A, magnetic releases I
NSE0_01540a
I6 DK
i
n =160 A
i

CAT.A
1250

2500

NSE0_00707
2

Starter protection, M, I function


Without overcurrent release, with adjustable short-circuit release
VL160/3VL2
63
450 ... 900
100
750 ... 1500
160
1250 ... 2500

B
B
B

3VL27 06-1DK3@-....
3VL27 10-1DK3@-....
3VL27 16-1DK3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200
2.200
2.200

VL250/3VL3

3VL37 25-1DK3@-....

1 unit

113

2.300

250

1750 ... 3500

Connection type can be selected by assignment of the 12th position of the Order No. >
Connection with box terminal
Connection with screw terminal

3
6

VL400/3VL4

200
250
315

1250 ... 2500


2000 ... 4000
2000 ... 4000

B
B
B

3VL47 20-1DK36-....
3VL47 25-1DK36-....
3VL47 31-1DK36-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

5.700
5.700
5.700

VL630/3VL5

315
500

2000 ... 4000


3250 ... 6300

B
B

3VL57 31-1DK36-....
3VL57 50-1DK36-....

1
1

1 unit
1 unit

113
113

9.000
9.000

Without overcurrent release, with non-adjustable short-circuit release (for intrinsic protection only)
3VL17 10-1DE3@-....
VL160X/3VL1
100
1800
B
160
1800
B
3VL17 16-1DE3@-....

1
1

1 unit
1 unit

113
113

2.000
2.000

3-pole, fixed-mounted, for safe disconnection,


100 A to 1600 A, magnetic releases I

NSE0_00708

Non-automatic molded case circuit breakers1), I function

VL160/3VL2

100
160

2500
2500

B
B

3VL27 10-1DE3@-....
3VL27 16-1DE3@-....

1
1

1 unit
1 unit

113
113

2.200
2.200

VL250/3VL3

250

3500

3VL37 25-1DE3@-....

1 unit

113

2.300

5.700

Connection type can be selected by assignment of the 12th position of the Order
Connection with box terminal
Connection with screw terminal not in conjunction with RCD module at 3VL1

>
3
6

VL400/3VL4

400

4000

3VL47 40-1DE36-....

1 unit

113

VL630/3VL5

630

6300

3VL57 63-1DE36-....

1 unit

113

9.000

VL800/3VL6

800

6500

3VL67 80-1DE36-....

1 unit

113

15.700

VL1250/3VL7

1250

12000

3VL77 12-1DE36-....

1 unit

113

23.500

VL1600/3VL82)

1600

14400

3VL87 16-1DE30-....

1 unit

113

29.800

For further versions, including for short-circuit and


ground-fault protection, see pages 2/12 to 2/28.
1)

See also "Switch Disconnectors" chapter. 3K. switch disconnectors are


also available with rear-mounting operating mechanism and leading contacts.

2)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

* You can order this quantity or a multiple thereof.

2/30

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2DK3@-....
3VL27 10-2DK3@-....
3VL27 16-2DK3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200 B
2.200 B
2.200 B

3VL27 06-3DK3@-....
3VL27 10-3DK3@-....
3VL27 16-3DK3@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

2.200
2.200
2.200

3VL37 25-2DK3@-....

1 unit

113

2.300 B

3VL37 25-3DK3@-....

1 unit

113

2.300

>

>

3
6

3
6

B
B
B

3VL47 20-2DK36-....
3VL47 25-2DK36-....
3VL47 31-2DK36-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

5.700 B
5.700 B
5.700 B

3VL47 20-3DK36-....
3VL47 25-3DK36-....
3VL47 31-3DK36-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

5.700
5.700
5.700

B
B

3VL57 31-2DK36-....
3VL57 50-2DK36-....

1
1

1 unit
1 unit

113
113

9.000 B
9.000 B

3VL57 31-3DK36-....
3VL57 50-3DK36-....

1
1

1 unit
1 unit

113
113

9.000
9.000

B
B

3VL17 10-2DE3@-....
3VL17 16-2DE3@-....

1
1

1 unit
1 unit

113
113

2.000
2.000

---

B
B

3VL27 10-2DE3@-....
3VL27 16-2DE3@-....

1
1

1 unit
1 unit

113
113

2.200 B
2.200 B

3VL27 10-3DE3@-....
3VL27 16-3DE3@-....

1
1

1 unit
1 unit

113
113

2.200
2.200

3VL37 25-2DE3@-....

1 unit

113

2.300 B

3VL37 25-3DE3@-....

1 unit

113

2.300

5.700

>
3
6

>
3
6

3VL47 40-2DE36-....

1 unit

113

5.700 B

3VL47 40-3DE36-....

1 unit

113

3VL57 63-2DE36-....

1 unit

113

9.000 B

3VL57 63-3DE36-....

1 unit

113

9.000

3VL67 80-2DE36-....

1 unit

113

15.700 B

3VL67 80-3DE36-....

1 unit

113

15.700

3VL77 12-2DE36-....

1 unit

113

23.500 B

3VL77 12-3DE36-....

1 unit

113

23.500

3VL87 16-2DE30-....

1 unit

113

29.800 B

3VL87 16-3DE30-....

1 unit

113

29.800

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/31

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


3-pole
Order No. supple- Switchment (for complete ing
capacity
Order No., see
pages 2/12 to 2/28)
3VL.7 ..-. @@3.-....

Type
VL160
3VL2

Releases

63 A

VL250
3VL3

VL400
3VL4

VL630
3VL5

VL800
3VL6

VL1250
3VL7

800 A

1000 A

VL1600
3VL8

Rated current In
100 A

160 A

200 A

250 A

315 A

400 A

500 A

630 A

1250 A

1600 A

Price
ETU10

ETU10

ETU10

ETU12

ETU12

ETU12

ETU12

ETU20

ETU20

ETU20

ETU22

ETU22

ETU42

ETU42

ETU22

ETU22

ETU40

SB

MB

LB

SL

ML

SF

MF

SE

ME

LE

SG

MG

CL

CM

SH

MH

CH

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

Available
-- Not available

2/32

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
3-pole
Order No. supple- Switchment (for complete ing
capacity
Order No., see
pages 2/12 to 2/28)
3VL.7 ..-. @@3.-....

Type
VL160
3VL2

Releases

63 A

VL250
3VL3

VL400
3VL4

VL630
3VL5

VL800
3VL6

VL1250
3VL7

VL1600
3VL8

630 A

800 A

1000 A

1250 A

1600 A

Rated current In
100 A

160 A

200 A

250 A

315 A

400 A

500 A

Price
ETU10M S P

ETU10M M P

ETU30M S S

ETU30M M S

ETU30M L S

ETU40M C P

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

----

Available
-- Not available

Siemens LV 10.1 2011

2/33

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole

Selection and ordering data


Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of the DT


**
instantaneous
short-circuit releases "I"
Ii

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

N
PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection, 16 A to 630 A,


thermal-magnetic releases LI
NSE0_00539a
OFF
TM ~
=
50 C
CAT.A

63A

NSE0_00695

System protection, TM, LI function


With non-adjustable thermal overcurrent releases, non-adjustable short-circuit releases,
without overcurrent and short-circuit release in 4th pole (N)
3VL17 96-1EH4@-....
VL160X/3VL1
16
16
300
B
3VL17 02-1EH4@-....
20
20
300
B
25
25
300
B
3VL17 25-1EH4@-....
3VL17 03-1EH4@-....
32
32
300
B
3VL17 04-1EH4@-....
40
40
600
B
50
50
600
B
3VL17 05-1EH4@-....
3VL17 06-1EH4@-....
63
63
600
B
3VL17 08-1EH4@-....
80
80
1000
B
100
100
1000
B
3VL17 10-1EH4@-....
3VL17 12-1EH4@-....
125
125
1000
B
3VL17 16-1EH4@-....
160
160
1500
B

1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113
113
113
113
113
113

2.300
2.300
2.500
2.500
2.500
2.500
2.500
2.500
2.500
2.500
2.500

3VL27 05-1EJ4@-....
3VL27 06-1EJ4@-....
3VL27 08-1EJ4@-....
3VL27 10-1EJ4@-....
3VL27 12-1EJ4@-....
3VL27 16-1EJ4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

3.000
3.000
3.000
3.000
3.000
3.000

3VL37 20-1EJ4@-....
3VL37 25-1EJ4@-....

1
1

1 unit
1 unit

113
113

3.200
3.200

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal not in conjunction with RCD module
6
NSE0_-00541a
I

Ii

I n =160A

I
7
6
5

16 DC
1.0

50 C
9 xI
n

I I
R i
~
TM = CAT.A

10

xI n

.8

NSE0_00704

System protection, TM, LI function


With adjustable thermal overcurrent releases, adjustable short-circuit releases,
without overcurrent and short-circuit release in 4th pole (N)
VL160/3VL2
50
40 ... 50
300 ... 600
B
63
50 ... 63
300 ... 600
B
80
63 ... 80
400 ... 800
B
100
80 ... 100
500 ... 1000
B
125
100 ... 125
625 ... 1250
B
160
125 ... 160
800 ... 1600
B
VL250/3VL3

200
250

160 ... 200


200 ... 250

1000 ... 2000


1250 ... 2500

B
B

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

200
250
315
400

160 ... 200


200 ... 250
250 ... 315
320 ... 400

1000 ... 2000


1250 ... 2500
1575 ... 3150
2000 ... 4000

B
B
B
B

3VL47 20-1EJ46-....
3VL47 25-1EJ46-....
3VL47 31-1EJ46-....
3VL47 40-1EJ46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

VL630/3VL5

315
400
500
630

250 ... 315


320 ... 400
400 ... 500
500 ... 630

1575 ... 3150


2000 ... 4000
2500 ... 5000
3150 ... 6300

B
B
B
B

3VL57 31-1EJ46-....
3VL57 40-1EJ46-....
3VL57 50-1EJ46-....
3VL57 63-1EJ46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

** Delivery time class A for Order No. supplement "0AA0", see page 2/57.

* You can order this quantity or a multiple thereof.

2/34

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole

DT Icu up to 70 kA at 415 V,
** high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

B
B
B
B
B
B
B
B
B
B
B

3VL17 96-2EH4@-....
3VL17 02-2EH4@-....
3VL17 25-2EH4@-....
3VL17 03-2EH4@-....
3VL17 04-2EH4@-....
3VL17 05-2EH4@-....
3VL17 06-2EH4@-....
3VL17 08-2EH4@-....
3VL17 10-2EH4@-....
3VL17 12-2EH4@-....
3VL17 16-2EH4@-....

>

Basic price
per PU

DT
**

H
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

Order No.
Order No. supplement
required,
see page 2/57

kg

1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113
113
113
113
113
113

2.300
2.300
2.500
2.500
2.500
2.500
2.500
2.500
2.500
2.500
2.500

Icu up to 100 kA at 415 V,


very high switching capacity L

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

------------

3
6

B
B
B
B
B
B

3VL27 05-2EJ4@-....
3VL27 06-2EJ4@-....
3VL27 08-2EJ4@-....
3VL27 10-2EJ4@-....
3VL27 12-2EJ4@-....
3VL27 16-2EJ4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

3.000
3.000
3.000
3.000
3.000
3.000

B
B
B
B
B
B

3VL27 05-3EJ4@-....
3VL27 06-3EJ4@-....
3VL27 08-3EJ4@-....
3VL27 10-3EJ4@-....
3VL27 12-3EJ4@-....
3VL27 16-3EJ4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

3.000
3.000
3.000
3.000
3.000
3.000

B
B

3VL37 20-2EJ4@-....
3VL37 25-2EJ4@-....

1
1

1 unit
1 unit

113
113

3.200 B
3.200 B

3VL37 20-3EJ4@-....
3VL37 25-3EJ4@-....

1
1

1 unit
1 unit

113
113

3.200
3.200

>

>

3
6

3
6

B
B
B
B

3VL47 20-2EJ46-....
3VL47 25-2EJ46-....
3VL47 31-2EJ46-....
3VL47 40-2EJ46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

B
B
B
B

3VL47 20-3EJ46-....
3VL47 25-3EJ46-....
3VL47 31-3EJ46-....
3VL47 40-3EJ46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

B
B
B
B

3VL57 31-2EJ46-....
3VL57 40-2EJ46-....
3VL57 50-2EJ46-....
3VL57 63-2EJ46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

B
B
B
B

3VL57 31-3EJ46-....
3VL57 40-3EJ46-....
3VL57 50-3EJ46-....
3VL57 63-3EJ46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

** Delivery time class A for Order No. supplement "0AA0", see page 2/57.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/35

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of the DT


**
instantaneous
short-circuit releases "I"
Ii

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

N
PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection, 16 A to 160 A,


thermal-magnetic releases LIN
NSE0_00539a
OFF
TM ~
=
50 C
CAT.A

63A

NSE0_00695

System protection, TM, LIN function


With non-adjustable thermal overcurrent releases, non-adjustable short-circuit releases,
with "N" overcurrent and short-circuit release
N protection = 100 %
3VL17 96-1EA4@-....
VL160X/3VL1
16
16
300
B
3VL17 02-1EA4@-....
20
20
300
B
25
25
300
B
3VL17 25-1EA4@-....
3VL17 03-1EA4@-....
32
32
300
B
3VL17 04-1EA4@-....
40
40
600
B
50
50
600
B
3VL17 05-1EA4@-....
63
80
100
125
160

63
80
100
125
160

600
1000
1000
1000
1500

B
B
B
B
B

3VL17 06-1EA4@-....
3VL17 08-1EA4@-....
3VL17 10-1EA4@-....
3VL17 12-1EL4@-....
3VL17 16-1EL4@-....

>

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

2.300
2.300
2.500
2.500
2.500
2.500

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

2.500
2.500
2.500
2.500
2.500

1
1

1 unit
1 unit

113
113

2.500
2.500

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal not in conjunction with RCD module
6
NSE0_00539a
OFF
TM ~
=
50 C
CAT.A

63A

NSE0_00695

System protection, TM, LIN function


With non-adjustable thermal overcurrent releases, non-adjustable short-circuit releases,
with "N" overcurrent and short-circuit release
N protection = 60 %
3VL17 12-1EA4@-....
VL160X/3VL1
125
125
1000
B
3VL17 16-1EA4@-....
160
160
1500
B

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal not in conjunction with RCD module
6

** Delivery time class A for Order No. supplement "0AA0", see page 2/57.

* You can order this quantity or a multiple thereof.

2/36

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT Icu up to 70 kA at 415 V,
** high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT
**

H
Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

B
B
B
B
B
B

3VL17 96-2EA4@-....
3VL17 02-2EA4@-....
3VL17 25-2EA4@-....
3VL17 03-2EA4@-....
3VL17 04-2EA4@-....
3VL17 05-2EA4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

2.300
2.300
2.500
2.500
2.500
2.500

-------

B
B
B
B
B

3VL17 06-2EA4@-....
3VL17 08-2EA4@-....
3VL17 10-2EA4@-....
3VL17 12-2EL4@-....
3VL17 16-2EL4@-....

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

2.500
2.500
2.500
2.500
2.500

------

1
1

1 unit
1 unit

113
113

2.500
2.500

---

>

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

3
6

B
B

3VL17 12-2EA4@-....
3VL17 16-2EA4@-....

>
3
6

** Delivery time class A for Order No. supplement "0AA0", see page 2/57.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/37

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of the DT


instantaneous
short-circuit releases "I"
Ii

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

N
PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection, 16 A to 630 A,


thermal-magnetic releases LIN
NSE0_-00541a
I

Ii

I n =160A

50 C
9 xI
n

16 DC
1.0

I I
R i
~
TM = CAT.A

xI n

10

.8

NSE0_00691

System protection, TM, LIN function


With adjustable thermal overcurrent releases, adjustable short-circuit releases,
with "N" overcurrent and short-circuit release
N protection = 100 %
VL160/3VL2
50
40 ... 50
300 ... 600
B
63
50 ... 63
300 ... 600
B
80
63 ... 80
400 ... 800
B
100
80 ... 100
500 ... 1000
B
125
100 ... 125
625 ... 1250
B
160
125 ... 160
800 ... 1600
B
VL250/3VL3

200
250

160 ... 200


200 ... 250

1000 ... 2000


1250 ... 2500

B
B

3VL27 05-1EM4@-....
3VL27 06-1EM4@-....
3VL27 08-1EM4@-....
3VL27 10-1EM4@-....
3VL27 12-1EM4@-....
3VL27 16-1EM4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

3.000
3.000
3.000
3.000
3.000
3.000

3VL37 20-1EM4@-....
3VL37 25-1EM4@-....

1
1

1 unit
1 unit

113
113

3.200
3.200

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

200
250
315
400

160 ... 200


200 ... 250
250 ... 315
320 ... 400

1000 ... 2000


1250 ... 2500
1575 ... 3150
2000 ... 4000

B
B
B
B

3VL47 20-1EM46-....
3VL47 25-1EM46-....
3VL47 31-1EM46-....
3VL47 40-1EM46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

VL630/3VL5

315
400
500
630

250 ... 315


320 ... 400
400 ... 500
500 ... 630

1575 ... 3150


2000 ... 4000
2500 ... 5000
3150 ... 6300

B
B
B
B

3VL57 31-1EM46-....
3VL57 40-1EM46-....
3VL57 50-1EM46-....
3VL57 63-1EM46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

With adjustable thermal overcurrent releases, adjustable short-circuit releases,


with "N" overcurrent and short-circuit release
N protection = 60 %
VL160/3VL2
125
100 ... 125
625 ... 1250
B
160
125 ... 160
800 ... 1600
B

3VL27 12-1EC4@-....
3VL27 16-1EC4@-....

1
1

1 unit
1 unit

113
113

3.000
3.000

3VL37 20-1EC4@-....
3VL37 25-1EC4@-....

1
1

1 unit
1 unit

113
113

3.200
3.200

NSE0_-00541a
I

Ii
I n =160A

7
6

16 DC
1.0

50 C
9 xI
n

I I
R i
~
TM = CAT.A

10

xI n

.8

NSE0_00691

System protection, TM, LIN function

VL250/3VL3

200
250

160 ... 200


200 ... 250

1000 ... 2000


1250 ... 2500

B
B

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

200
250
315
400

160 ... 200


200 ... 250
250 ... 315
320 ... 400

1000 ... 2000


1250 ... 2500
1575 ... 3150
2000 ... 4000

B
B
B
B

3VL47 20-1EC46-....
3VL47 25-1EC46-....
3VL47 31-1EC46-....
3VL47 40-1EC46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

VL630/3VL5

315
400
500
630

250 ... 315


320 ... 400
400 ... 500
500 ... 630

1575 ... 3150


2000 ... 4000
2500 ... 5000
3150 ... 6300

B
B
B
B

3VL57 31-1EC46-....
3VL57 40-1EC46-....
3VL57 50-1EC46-....
3VL57 63-1EC46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

* You can order this quantity or a multiple thereof.

2/38

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

kg

Basic price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

B
B
B
B
B
B

3VL27 05-2EM4@-....
3VL27 06-2EM4@-....
3VL27 08-2EM4@-....
3VL27 10-2EM4@-....
3VL27 12-2EM4@-....
3VL27 16-2EM4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

3.000
3.000
3.000
3.000
3.000
3.000

B
B
B
B
B
B

3VL27 05-3EM4@-....
3VL27 06-3EM4@-....
3VL27 08-3EM4@-....
3VL27 10-3EM4@-....
3VL27 12-3EM4@-....
3VL27 16-3EM4@-....

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113
113

3.000
3.000
3.000
3.000
3.000
3.000

B
B

3VL37 20-2EM4@-....
3VL37 25-2EM4@-....

1
1

1 unit
1 unit

113
113

3.200 B
3.200 B

3VL37 20-3EM4@-....
3VL37 25-3EM4@-....

1
1

1 unit
1 unit

113
113

3.200
3.200

>
3
6

>
3
6

B
B
B
B

3VL47 20-2EM46-....
3VL47 25-2EM46-....
3VL47 31-2EM46-....
3VL47 40-2EM46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

B
B
B
B

3VL47 20-3EM46-....
3VL47 25-3EM46-....
3VL47 31-3EM46-....
3VL47 40-3EM46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

B
B
B
B

3VL57 31-2EM46-....
3VL57 40-2EM46-....
3VL57 50-2EM46-....
3VL57 63-2EM46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

B
B
B
B

3VL57 31-3EM46-....
3VL57 40-3EM46-....
3VL57 50-3EM46-....
3VL57 63-3EM46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

B
B

3VL27 12-2EC4@-....
3VL27 16-2EC4@-....

1
1

1 unit
1 unit

113
113

3.000 B
3.000 B

3VL27 12-3EC4@-....
3VL27 16-3EC4@-....

1
1

1 unit
1 unit

113
113

3.000
3.000

B
B

3VL37 20-2EC4@-....
3VL37 25-2EC4@-....

1
1

1 unit
1 unit

113
113

3.200 B
3.200 B

3VL37 20-3EC4@-....
3VL37 25-3EC4@-....

1
1

1 unit
1 unit

113
113

3.200
3.200

>
3
6

>
3
6

B
B
B
B

3VL47 20-2EC46-....
3VL47 25-2EC46-....
3VL47 31-2EC46-....
3VL47 40-2EC46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

B
B
B
B

3VL47 20-3EC46-....
3VL47 25-3EC46-....
3VL47 31-3EC46-....
3VL47 40-3EC46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

7.400
7.400
7.400
7.400

B
B
B
B

3VL57 31-2EC46-....
3VL57 40-2EC46-....
3VL57 50-2EC46-....
3VL57 63-2EC46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

B
B
B
B

3VL57 31-3EC46-....
3VL57 40-3EC46-....
3VL57 50-3EC46-....
3VL57 63-3EC46-....

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

11.200
11.200
11.200
11.200

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/39

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current setting of the


inverse-time delayed
overcurrent releases
"L"
IR

Operating current of DT
the instantaneous
short-circuit releases
"I"
Ii

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

For price
PU
see page (UNIT,
2/54 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection,


63 A to 1600 A, electronic releases LI
NSE0_02119

I R 1.0 .4
.95

.45

.9
X3

.5

.8
.6
x I n .7 .63

t R (S) 30 2.5
25

Ii

10

20

17
14 10

Alarm
>1.05

11 1.25
1.5
2

8
6
xI n 5

Active

3
4

NSE0_00691

ETU10, LI function
With adjustable overcurrent releases, adjustable short-circuit releases
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
100
40 ... 100
1.25 ... 11 In
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

B
B
B

3VL27 06-1@@4@-....
3VL27 10-1@@4@-....
3VL27 16-1@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-1@@4@-....
3VL37 25-1@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL47 31-1@@46-....
3VL47 40-1@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

252 ... 630

1.25 ... 10 In

3VL57 63-1@@46-....

1 unit

113

11.700

VL800/3VL6

800

320 ... 800

1.25 ... 8 In

3VL67 80-1@@46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL77 10-1@@46-....
3VL77 12-1@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

VL1600/3VL81)

1600

640 ... 1600

1.25 ... 9 In

3VL87 16-1@@40-....

1 unit

113

40.800

>

Without communication preparation


With communication preparation

TB
NB

4-pole, fixed-mounted, for system protection,


63 A to 1600 A, electronic releases LIN
NSE0_02077

I R 1.0 .4
.95

L
X3

.45

.9
.5
.8
.6
x I n .7 .63

t R (S) 30 2.5
25

4
6

20

17
14 10

Ii

11 1.25
1.5
10

Alarm
>1.05

8
6
xI n 5

IN

3
4

IN

100%

IN

Active

50%

NSE0_00691

ETU10, LIN function


With adjustable overcurrent releases, adjustable short-circuit releases,
with overcurrent and short-circuit release in 4th pole (N)
N protection = 50/100 %
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
100
40 ... 100
1.25 ... 11 In
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

B
B
B

3VL27 06-1@@4@-....
3VL27 10-1@@4@-....
3VL27 16-1@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-1@@4@-....
3VL37 25-1@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL47 31-1@@46-....
3VL47 40-1@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

252 ... 630

1.25 ... 10 In

3VL57 63-1@@46-....

1 unit

113

11.700

VL800/3VL6

800

320 ... 800

1.25 ... 8 In

3VL67 80-1@@46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

B
B

3VL77 10-1@@46-....
3VL77 12-1@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

VL1600/3VL81)

1600

640 ... 1600

1.25 ... 9 In

3VL87 16-1@@40-....

1 unit

113

40.800

1)

>

Without communication preparation


TA
With communication preparation
NA
Marine engineering-certified LRS, DNV and GL (not communication-ready) LA

Front busbar connection pieces are included in the scope of supply and
are to be fitted by the customer.

* You can order this quantity or a multiple thereof.

2/40

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/54

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/54

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@4@-....
3VL27 10-2@@4@-....
3VL27 16-2@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3@@4@-....
3VL27 10-3@@4@-....
3VL27 16-3@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2@@4@-....
3VL37 25-2@@4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3@@4@-....
3VL37 25-3@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

>

3
6

3
6

B
B

3VL47 31-2@@46-....
3VL47 40-2@@46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3@@46-....
3VL47 40-3@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2@@46-....

1 unit

113

11.700 B

3VL57 63-3@@46-....

1 unit

113

11.700

3VL67 80-2@@46-....

1 unit

113

20.500 B

3VL67 80-3@@46-....

1 unit

113

20.500

B
B

3VL77 10-2@@46-....
3VL77 12-2@@46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3@@46-....
3VL77 12-3@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2@@40-....

1 unit

113

40.800 B

3VL87 16-3@@40-....

1 unit

113

40.800

>
TB
NB

>
TB
NB

B
B
B

3VL27 06-2@@4@-....
3VL27 10-2@@4@-....
3VL27 16-2@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3@@4@-....
3VL27 10-3@@4@-....
3VL27 16-3@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2@@4@-....
3VL37 25-2@@4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3@@4@-....
3VL37 25-3@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

>

3
6

3
6

B
B

3VL47 31-2@@46-....
3VL47 40-2@@46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3@@46-....
3VL47 40-3@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2@@46-....

1 unit

113

11.700 B

3VL57 63-3@@46-....

1 unit

113

11.700

3VL67 80-2@@46-....

1 unit

113

20.500 B

3VL67 80-3@@46-....

1 unit

113

20.500

B
B

3VL77 10-2@@46-....
3VL77 12-2@@46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3@@46-....
3VL77 12-3@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2@@40-....

1 unit

113

40.800 B

3VL87 16-3@@40-....

1 unit

113

40.800

>
TA
NA
LA

Communication:
For accessories, see page 2/98.

>
TA
NA
LA

For more information see also chapters "Measuring Devices and


E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/41

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated Current
current setting of the
In
inverse-time
delayed
overcurrent
releases "L"
IR

Operating
current of the
instantaneous
short-circuit
releases "I"
Ii

Ground-fault
protection "G"
Ig

DT

Icu up to 55 kA at 415 V, standard switching capacity N


See "Overview".
Order No.
Order No. supplement
required,
see page 2/57

For price
PU
see page (UNIT,
2/54 SET, M)

PS*/
P. unit

N
PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection, 63 A to 1600 A,


electronic releases LING
NSE0_02079

I R 1.0 .4
.95

L
I

.45

.9
X3

.8

x I n .7 .63

.5
.6

t R (S) 30 2.5
25

4
6

20

17
14 10

Alarm
Ig I t g OFF .6/.1
11 1.25
>1.05
1.5
10
1/.3
1/.1
.6/.3
2 .6/.3
8
Active
1/.3
6
3 I 1/.1
IN
N
OFF 50%
xI n 5 4
100% .6/.1

Ii

NSE0_00693

ETU12, LING function for 4-wire three-phase systems


With adjustable overcurrent releases, adjustable short-circuit releases,
vectorial summation current, ground-fault delay tg = 0.1 ... 0.3 s, ground-fault protection (G) can be switched off
with overcurrent and short-circuit release in 4th pole (N), N protection = 50/100 %
0.6 ... 1 In, OFF B
3VL27 06-1@@4@-....
VL160/3VL2
63
25 ... 63
1.25 ... 11 In
0.6 ... 1 In, OFF B
3VL27 10-1@@4@-....
100
40 ... 100
1.25 ... 11 In
160
64 ... 160
1.25 ... 11 In
0.6 ... 1 In, OFF B
3VL27 16-1@@4@-....
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL37 20-1@@4@-....
3VL37 25-1@@4@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

1
1

1 unit
1 unit

113
113

3.300
3.300

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

1.25 ... 11 In
1.25 ... 11 In

VL630/3VL5

630

252 ... 630

VL800/3VL6

800

320 ... 800

VL1250/3VL7

1000
1250

VL1600/3VL81)

1600

0.6 ... 1 In, OFF B


0.6 ... 1 In, OFF B

3VL47 31-1@@46-....
3VL47 40-1@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

1.25 ... 10 In

0.6 ... 1 In, OFF

3VL57 63-1@@46-....

1 unit

113

11.700

1.25 ... 8 In

0.6 ... 1 In, OFF

3VL67 80-1@@46-....

1 unit

113

20.500

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

0.6 ... 1 In, OFF


0.6 ... 1 In, OFF

B
B

3VL77 10-1@@46-....
3VL77 12-1@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

640 ... 1600

1.25 ... 9 In

0.6 ... 1 In, OFF

3VL87 16-1@@40-....

1 unit

113

40.800

Without communication preparation


With communication preparation
1)

>
TN
NN

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

2/42

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
PU
see page (UNIT,
2/54 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.

kg

Order No. supplement


required,
see page 2/57

For price
PU
see page (UNIT,
2/54 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

B
B
B

3VL27 06-2@@4@-....
3VL27 10-2@@4@-....
3VL27 16-2@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3@@4@-....
3VL27 10-3@@4@-....
3VL27 16-3@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2@@4@-....
3VL37 25-2@@4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3@@4@-....
3VL37 25-3@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

>

3
6

3
6

B
B

3VL47 31-2@@46-....
3VL47 40-2@@46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3@@46-....
3VL47 40-3@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2@@46-....

1 unit

113

11.700 B

3VL57 63-3@@46-....

1 unit

113

11.700

3VL67 80-2@@46-....

1 unit

113

20.500 B

3VL67 80-3@@46-....

1 unit

113

20.500

B
B

3VL77 10-2@@46-....
3VL77 12-2@@46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3@@46-....
3VL77 12-3@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2@@40-....

1 unit

113

40.800 B

3VL87 16-3@@40-....

1 unit

113

40.800

>
TN
NN

>
TN
NN

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/43

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current setting of
the inverse-time
delayed overcurrent releases
"L"
IR

Operating current
of the instantaneous short-circuit
releases "I"
Ii

S function short- DT
circuit protection
(short-time
delayed)
S

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LI, LSI, LIN, LSIN
NSE-00547a

L
ESC

L1=178; L2=181

L3=179; N=0

NSE0_00696

CAT.A

n=250

25 CL

A~

LCD-ETU40, LI/LSI/LIN/LSIN function selectable


With adjustable overcurrent releases, adjustable short-circuit releases,
short-circuit delay tsd = 0 ... 0.5 s
with overcurrent and short-circuit release in 4th pole (N), N protection = 50 ... 100 %, OFF
25 ... 63
1.25 ... 11 In
1.5 ... 10xIR
B
3VL27 06-1CJ4@-....
VL160/3VL2
632)
1002)
40 ... 100
1.25 ... 11 In
1.5 ... 10xIR
B
3VL27 10-1CJ4@-....
1.5 ... 10xIR
B
3VL27 16-1CJ4@-....
160
64 ... 160
1.25 ... 11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In
1.25 ... 11 In

1.5 ... 10xIR


1.5 ... 10xIR

B
B

3VL37 20-1CJ4@-....
3VL37 25-1CJ4@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal
VL400/3VL4

315
400

128 ... 315


160 ... 400

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

1
1

1 unit
1 unit

113
113

3.300
3.300

3
6

1.25 ... 11 In
1.25 ... 11 In

1.5 ... 10xIR


1.5 ... 10xIR

B
B

3VL47 31-1CJ46-....
3VL47 40-1CJ46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

252 ... 630

1.25 ... 10 In

1.5 ... 9xIR

3VL57 63-1CJ46-....

1 unit

113

11.700

VL800/3VL6

800

320 ... 800

1.25 ... 8 In

1.5 ... 7xIR

3VL67 80-1CJ46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

1.25 ... 11 In
1.25 ... 11 In

1.5 ... 10xIR


1.5 ... 10xIR

B
B

3VL77 10-1CJ46-....
3VL77 12-1CJ46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

1600

640 ... 1600

1.25 ... 9 In

1.5 ... 8xIR

3VL87 16-1CJ40-....

1 unit

113

40.800

VL1600/3VL8

1)

1)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

2)

N = 100 % protection for In  100 A.

* You can order this quantity or a multiple thereof.

2/44

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2CJ4@-....
3VL27 10-2CJ4@-....
3VL27 16-2CJ4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3CJ4@-....
3VL27 10-3CJ4@-....
3VL27 16-3CJ4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2CJ4@-....
3VL37 25-2CJ4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3CJ4@-....
3VL37 25-3CJ4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>
3
6

>
3
6

B
B

3VL47 31-2CJ46-....
3VL47 40-2CJ46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3CJ46-....
3VL47 40-3CJ46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2CJ46-....

1 unit

113

11.700 B

3VL57 63-3CJ46-....

1 unit

113

11.700

3VL67 80-2CJ46-....

1 unit

113

20.500 B

3VL67 80-3CJ46-....

1 unit

113

20.500

B
B

3VL77 10-2CJ46-....
3VL77 12-2CJ46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3CJ46-....
3VL77 12-3CJ46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2CJ40-....

1 unit

113

40.800 B

3VL87 16-3CJ40-....

1 unit

113

40.800

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/45

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current
setting of the
inverse-time
delayed
overcurrent
releases
"L"
IR

Operating
current of the
instantaneous
short-circuit
releases "I" Ii

S function
shortcircuit
protection
(short-time
delayed)
S

Ground-fault DT
protection
"G"
Ig

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSIG, LSING
NSE-00547a

L
ESC

L1=178; L2=181

S
I

L3=179; N=0

NSE0_00697

CAT.A

n=250

A~

25 CL

LCD-ETU42, LSIG/LSING function for 4-wire three-phase systems and time-based discrimination
With adjustable overcurrent releases, adjustable short-circuit releases
Ground fault delay tg = 0.1 ... 0.5 s, short-circuit delay tsd = 0 ... 0.3 s
with overcurrent and short-circuit release in 4th pole (N), N protection = 50 ... 100 %, OFF
3VL27 06-1CN4@-....
VL160/3VL2
63
25 ... 63
1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B
100
40 ... 100
1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B
3VL27 10-1CN4@-....
3VL27 16-1CN4@-....
160
64 ... 160
1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B


1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B

3VL37 20-1CN4@-....
3VL37 25-1CN4@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal
VL400/3VL4

315
400

128 ... 315


160 ... 400

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

1
1

1 unit
1 unit

113
113

3.300
3.300

3
6

1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B


1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B

3VL47 31-1CN46-....
3VL47 40-1CN46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

252 ... 630

1.25 ... 10 In 1.5 ... 9xIR 0.4 ... 1 In B

3VL57 63-1CN46-....

1 unit

113

11.700

VL800/3VL6

800

320 ... 800

1.25 ... 8 In 1.5 ... 7xIR 0.4 ... 1 In B

3VL67 80-1CN46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B


1.25 ... 11 In 1.5 ... 10xIR 0.4 ... 1 In B

3VL77 10-1CN46-....
3VL77 12-1CN46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

1600

640 ... 1600

1.25 ... 9 In 1.5 ... 8xIR 0.4 ... 1 In B

3VL87 16-1CN40-....

1 unit

113

40.800

VL1600/3VL8
1)

1)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

* You can order this quantity or a multiple thereof.

2/46

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2CN4@-....
3VL27 10-2CN4@-....
3VL27 16-2CN4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3CN4@-....
3VL27 10-3CN4@-....
3VL27 16-3CN4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2CN4@-....
3VL37 25-2CN4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3CN4@-....
3VL37 25-3CN4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>
3
6

>
3
6

B
B

3VL47 31-2CN46-....
3VL47 40-2CN46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3CN46-....
3VL47 40-3CN46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2CN46-....

1 unit

113

11.700 B

3VL57 63-3CN46-....

1 unit

113

11.700

3VL67 80-2CN46-....

1 unit

113

20.500 B

3VL67 80-3CN46-....

1 unit

113

20.500

B
B

3VL77 10-2CN46-....
3VL77 12-2CN46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3CN46-....
3VL77 12-3CN46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2CN40-....

1 unit

113

40.800 B

3VL87 16-3CN40-....

1 unit

113

40.800

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/47

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current setting of
the inverse-time
delayed overcurrent releases
"L"
IR

Operating
current of the
instantaneous
short-circuit
releases "I"
Ii

S function DT
shortcircuit
protection
(short-time
delayed)
S

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

For price
PU
see page (UNIT,
2/54 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSI
NSE0_02120

I R 1.0 .4
.95

.45

.9
X3

I sd

.5

10 1.5
8

t sd(S) .4 0
.3

.2

2.5

.2

6
5

Active

.3 I t
3 I t .1
4 x I R ON .5 .4 OFF
2

.8
.6
x I n .7 .63

Alarm
>1.05

.1

NSE0_00692

ETU20, LSI function for time-based discrimination


With adjustable overcurrent releases, non-adjustable short-circuit releases, short-circuit delay (tsd = 0 to 0.5 s)
1.5 ... 10xIR B
3VL27 06-1@@4@-....
VL160/3VL2
63
25 ... 63
11 In
100
40 ... 100
11 In
1.5 ... 10xIR B
3VL27 10-1@@4@-....
1.5 ... 10xIR B
3VL27 16-1@@4@-....
160
64 ... 160
11 In
VL250/3VL3

200
250

80 ... 200
100 ... 250

1.5 ... 10xIR B


1.5 ... 10xIR B

11 In
11 In

3VL37 20-1@@4@-....
3VL37 25-1@@4@-....

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

1
1

1 unit
1 unit

113
113

3.300
3.300

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

128 ... 315


160 ... 400

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL47 31-1@@46-....
3VL47 40-1@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

252 ... 630

10 In

1.5 ... 9xIR B

3VL57 63-1@@46-....

1 unit

113

11.700

VL800/3VL6

800

320 ... 800

8 In

1.5 ... 7xIR B

3VL67 80-1@@46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL77 10-1@@46-....
3VL77 12-1@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

VL1600/3VL81)

1600

640 ... 1600

9 In

1.5 ... 8xIR B

3VL87 16-1@@40-....

1 unit

113

40.800

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

1
1

1 unit
1 unit

113
113

3.300
3.300

>

Without communication preparation


With communication preparation

TE
NE

4-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSIN
NSE0_02078

I R 1.0 .4
.95

S
X3

.45

.9
.5
.8
.6
x I n .7 .63

I sd

10 1.5
8

7
6
5

t sd(S) .4 0
.3

.1

IN

.2
2.5 .2
2
2
.3 I t IN
3 I t .1
4 x I R ON .5 .4 OFF 100%

Alarm
>1.05

IN

Active

50%

NSE0_00692

ETU20, LSIN function for time-based discrimination


With adjustable overcurrent releases, non-adjustable short-circuit releases, short-circuit delay (tsd = 0 to 0.5 s)
with overcurrent and short-circuit release in 4th pole (N), N protection = 50/100 %, OFF
11 In
1.5 ... 10xIR B
3VL27 06-1@@4@-....
VL160/3VL2
63
0.4 ...1.0 In
11 In
1.5 ... 10xIR B
3VL27 10-1@@4@-....
100
0.4 ...1.0 In
160
0.4 ...1.0 In
11 In
1.5 ... 10xIR B
3VL27 16-1@@4@-....
VL250/3VL3

200
250

0.4 ...1.0 In
0.4 ...1.0 In

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL37 20-1@@4@-....
3VL37 25-1@@4@-....

>

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
3
Connection with screw terminal
6
VL400/3VL4

315
400

0.4 ...1.0 In
0.4 ...1.0 In

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL47 31-1@@46-....
3VL47 40-1@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

0.4 ...1.0 In

10 In

1.5 ... 9xIR B

3VL57 63-1@@46-....

1 unit

113

11.700

VL800/3VL6

800

0.4 ...1.0 In

8 In

1.5 ... 7xIR B

3VL67 80-1@@46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

0.4 ...1.0 In
0.4 ...1.0 In

11 In
11 In

1.5 ... 10xIR B


1.5 ... 10xIR B

3VL77 10-1@@46-....
3VL77 12-1@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

VL1600/3VL81)

1600

0.4 ...1.0 In

9 In

1.5 ... 8xIR B

3VL87 16-1@@40-....

1 unit

113

40.800

1)

>

Without communication preparation


TF
With communication preparation
NF
Marine engineering-certified LRS, DNV and GL (not communication-ready) LF

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

Communication:

For accessories, see page 2/98.


For more information see also chapters "Measuring Devices
and E-Counters" and "Software".
* You can order this quantity or a multiple thereof.

2/48

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/54

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/54

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@4@-....
3VL27 10-2@@4@-....
3VL27 16-2@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3@@4@-....
3VL27 10-3@@4@-....
3VL27 16-3@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2@@4@-....
3VL37 25-2@@4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3@@4@-....
3VL37 25-3@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

>

3
6

3
6

B
B

3VL47 31-2@@46-....
3VL47 40-2@@46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3@@46-....
3VL47 40-3@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2@@46-....

1 unit

113

11.700 B

3VL57 63-3@@46-....

1 unit

113

11.700

3VL67 80-2@@46-....

1 unit

113

20.500 B

3VL67 80-3@@46-....

1 unit

113

20.500

B
B

3VL77 10-2@@46-....
3VL77 12-2@@46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3@@46-....
3VL77 12-3@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2@@40-....

1 unit

113

40.800 B

3VL87 16-3@@40-....

1 unit

113

40.800

>
TE
NE

>
TE
NE

B
B
B

3VL27 06-2@@4@-....
3VL27 10-2@@4@-....
3VL27 16-2@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3@@4@-....
3VL27 10-3@@4@-....
3VL27 16-3@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2@@4@-....
3VL37 25-2@@4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3@@4@-....
3VL37 25-3@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

>

3
6

3
6

B
B

3VL47 31-2@@46-....
3VL47 40-2@@46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3@@46-....
3VL47 40-3@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2@@46-....

1 unit

113

11.700 B

3VL57 63-3@@46-....

1 unit

113

11.700

3VL67 80-2@@46-....

1 unit

113

20.500 B

3VL67 80-3@@46-....

1 unit

113

20.500

B
B

3VL77 10-2@@46-....
3VL77 12-2@@46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3@@46-....
3VL77 12-3@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2@@40-....

1 unit

113

40.800 B

3VL87 16-3@@40-....

1 unit

113

40.800

>
TF
NF
LF

>
TF
NF
LF

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/49

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated
current
In

Current
setting of the
inverse-time
delayed
overcurrent
releases
"L"
IR

Operating
current of
the instantaneous
shortcircuit
releases
"I" Ii

S function Ground-fault
protection "G"
shortIg
circuit
protection
(short-time
delayed)
S

DT

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement required,
see page 2/57

For price
PU
see page (UNIT,
2/54 SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for system protection - generator protection,


63 A to 1600 A, electronic releases LSING
NSE0_02080

I R 1.0 .4
.95

.9

.45

X3

I sd

.5

.8
.6
x I n .7 .63

10 1.5
8

t sd(S) .4 0
.3

6
5

.1

Alarm
>1.05

1/.3
1/.1
.6/.3
.6/.3
Active
2
2
t
I
t
I
1/.3
.3
.1
1/.1
3
I
IN
.4
ON
N
.5
OFF
OFF 50%
4 xI R
100% .6/.1
2.5

Ig I t g OFF .6/.1

.2

.2

NSE0_00694

ETU22, LSING function for 4-wire three-phase systems and time-based discrimination
With adjustable overcurrent releases, adjustable short-circuit releases,
ground fault delay tg = 0.1 ... 0.3 s, ground-fault protection (G) can be switched off, short-circuit delay tsd = 0 ... 0.5 s
with overcurrent and short-circuit release in 4th pole (N), N protection = 50 ... 100 %, OFF
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 06-1@@4@-....
VL160/3VL2
63
25 ... 63
11 In
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 10-1@@4@-....
100
40 ... 100
11 In
160
64 ... 160
11 In
1.5 ... 10xIR 0.6 ... 1 In, OFF B
3VL27 16-1@@4@-....
VL250/3VL3

200
250

80 ... 200
100 ... 250

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL37 20-1@@4@-....
3VL37 25-1@@4@-....

Connection type can be selected by assignment of the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal

>

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

1
1

1 unit
1 unit

113
113

3.300
3.300

3
6

VL400/3VL4

315
400

128 ... 315


160 ... 400

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL47 31-1@@46-....
3VL47 40-1@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

VL630/3VL5

630

252 ... 630

10 In

1.5 ... 9xIR 0.6 ... 1 In, OFF B

3VL57 63-1@@46-....

1 unit

113

11.700

VL800/3VL6

800

320 ... 800

8 In

1.5 ... 7xIR 0.6 ... 1 In, OFF B

3VL67 80-1@@46-....

1 unit

113

20.500

VL1250/3VL7

1000
1250

400 ... 1000


500 ... 1250

11 In
11 In

1.5 ... 10xIR 0.6 ... 1 In, OFF B


1.5 ... 10xIR 0.6 ... 1 In, OFF B

3VL77 10-1@@46-....
3VL77 12-1@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

VL1600/3VL81) 1600

640 ... 1600

9 In

1.5 ... 8xIR 0.6 ... 1 In, OFF B

3VL87 16-1@@40-....

1 unit

113

40.800

Without communication preparation


With communication preparation
1)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

>
TH
NH

Communication:
For accessories, see page 2/98.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

* You can order this quantity or a multiple thereof.

2/50

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

DT

H
For price
see page
2/54

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

For price
see page
2/54

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B
B

3VL27 06-2@@4@-....
3VL27 10-2@@4@-....
3VL27 16-2@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100 B
3.100 B
3.100 B

3VL27 06-3@@4@-....
3VL27 10-3@@4@-....
3VL27 16-3@@4@-....

1
1
1

1 unit
1 unit
1 unit

113
113
113

3.100
3.100
3.100

B
B

3VL37 20-2@@4@-....
3VL37 25-2@@4@-....

1
1

1 unit
1 unit

113
113

3.300 B
3.300 B

3VL37 20-3@@4@-....
3VL37 25-3@@4@-....

1
1

1 unit
1 unit

113
113

3.300
3.300

>

>

3
6

3
6

B
B

3VL47 31-2@@46-....
3VL47 40-2@@46-....

1
1

1 unit
1 unit

113
113

7.600 B
7.600 B

3VL47 31-3@@46-....
3VL47 40-3@@46-....

1
1

1 unit
1 unit

113
113

7.600
7.600

3VL57 63-2@@46-....

1 unit

113

11.700 B

3VL57 63-3@@46-....

1 unit

113

11.700

3VL67 80-2@@46-....

1 unit

113

20.500 B

3VL67 80-3@@46-....

1 unit

113

20.500

B
B

3VL77 10-2@@46-....
3VL77 12-2@@46-....

1
1

1 unit
1 unit

113
113

33.500 B
33.500 B

3VL77 10-3@@46-....
3VL77 12-3@@46-....

1
1

1 unit
1 unit

113
113

33.500
33.500

3VL87 16-2@@40-....

1 unit

113

40.800 B

3VL87 16-3@@40-....

1 unit

113

40.800

>
TH
NH

>
TH
NH

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/51

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Type

Rated current In

Operating current
of the instantaneous
short-circuit releases "I"
Ii

DT

Icu up to 55 kA at 415 V,
standard switching capacity N
see "Overview"
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

N
PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

4-pole, fixed-mounted, for safe disconnection,


100 A to 1600 A, magnetic releases I

NSE0_00708

Non-automatic molded case circuit breakers1), I function


Without overcurrent releases, with non-adjustable short-circuit releases (for intrinsic protection only),
without overcurrent and short-circuit release in 4th pole (N)
3VL17 10-1EE4@-....
VL160X/3VL1
100
1800
B
3VL17 16-1EE4@-....
160
1800
B

1
1

1 unit
1 unit

113
113

2.500
2.500

VL160/3VL2

100
160

2500
2500

B
B

3VL27 10-1EE4@-....
3VL27 16-1EE4@-....

1
1

1 unit
1 unit

113
113

3.000
3.000

VL250/3VL3

250

3500

3VL37 25-1EE4@-....

1 unit

113

3.200

Connection type can be selected through the 12th position of the Order No.
Connection with box terminal
Connection with screw terminal not in conjunction with RCD module at 3VL1

>
3
6

VL400/3VL4

400

4000

3VL47 40-1EE46-....

1 unit

113

7.400

VL630/3VL5

630

6300

3VL57 63-1EE46-....

1 unit

113

11.200

VL800/3VL6

800

6500

3VL67 80-1EE46-....

1 unit

113

19.900

VL1250/3VL7

1250

12000

3VL77 12-1EE46-....

1 unit

113

31.000

VL1600/3VL82)

1600

14400

3VL87 16-1EE40-....

1 unit

113

38.300

1)

See also "Switch Disconnectors" chapter. 3K. switch disconnectors are


also available with rear-mounting operating mechanism and leading
contacts.

2)

Front busbar connection pieces are included in the scope of supply


and are to be fitted by the customer.

* You can order this quantity or a multiple thereof.

2/52

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
4-pole
DT

Icu up to 70 kA at 415 V,
high switching capacity H
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

DT

H
PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

Icu up to 100 kA at 415 V,


very high switching capacity L
Order No.
Order No. supplement
required,
see page 2/57

Basic price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

kg

kg

B
B

3VL17 10-2EE4@-....
3VL17 16-2EE4@-....

1
1

1 unit
1 unit

113
113

2.500
2.500

---

B
B

3VL27 10-2EE4@-....
3VL27 16-2EE4@-....

1
1

1 unit
1 unit

113
113

3.000 B
3.000 B

3VL27 10-3EE4@-....
3VL27 16-3EE4@-....

1
1

1 unit
1 unit

113
113

3.000
3.000

3VL37 25-2EE4@-....

1 unit

113

3.200 B

3VL37 25-3EE4@-....

1 unit

113

3.200

>
3
6

>
3
6

3VL47 40-2EE46-....

1 unit

113

7.400 B

3VL47 40-3EE46-....

1 unit

113

7.400

3VL57 63-2EE46-....

1 unit

113

11.200 B

3VL57 63-3EE46-....

1 unit

113

11.200

3VL67 80-2EE46-....

1 unit

113

19.900 B

3VL67 80-3EE46-....

1 unit

113

19.900

3VL77 12-2EE46-....

1 unit

113

31.000 B

3VL77 12-3EE46-....

1 unit

113

31.000

3VL87 16-2EE40-....

1 unit

113

38.300 B

3VL87 16-3EE40-....

1 unit

113

38.300

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/53

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


4-pole
Order No. supplement
Switching
(for complete Order No., capacity
see pages 2/40 to 2/50)
3VL.7 ..-.
@@4.-....

Type
VL160

VL250

VL400

VL630

VL800

VL1250

VL1600

3VL2

3VL3

3VL4

3VL5

3VL6

3VL7

3VL8

630 A

800 A

1000 A

Rated current In
Releases

63 A

100 A

160 A

200 A

250 A

315 A

400 A

1250 A

1600 A

Price
ETU10

ETU10

ETU10

ETU10

ETU10

ETU12

ETU12

ETU40

ETU42

ETU20

ETU20

ETU20

ETU20

ETU20

ETU22

ETU22

TB

NB

TA

NA

LA

TN

NN

CJ

CN

TE

NE

TF

NF

LF

TH

NH

Available

2/54

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Options

Selection and ordering data


When ordering, add "-Z" to the complete Order No. and add the
relevant order code(s).

Order No. with "-Z"


1234 5 6 7

8 9 10 11 12

13 14 15 16

Additional
price

3VL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@

+...+...
Code for
further versions -Z

For fixed-mounted circuit breakers (wired in factory)


Prewired internal accessories
For VL160X to VL1600
Connecting cables (3 m long)
(3VL1 to 3VL8)
brought out at the rear
This option "L02" can be selected only in combination
with internal accessories (page 2/57).

L 0 2

Prewired connecting cables for motorized


For VL160X to VL1600
operating mechanisms
(3VL1 to 3VL8)
Connecting cables on the circuit breaker for motorized operating mechanisms (3 m long).
On VL160X to VL400 brought out at the top.
On VL630 to VL1600 brought out on the right.
Motorized operating mechanism must be ordered
separately, see page 2/66.
This option "L12" can be selected only in combination
with motorized operating mechanisms
(see page 2/66).

L 1 2

Motorized operating mechanisms with stored


energy mechanisms
for synchronization tasks (24 V DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)

M2 4

Motorized operating mechanisms


for synchronization tasks (42 ... 48 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)

Motorized operating mechanisms


for synchronization tasks (60 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)

Motorized operating mechanisms


for synchronization tasks (110 ... 127 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)

Motorized operating mechanisms


for synchronization tasks (220 ... 250 V AC/DC)
Motorized operating mechanism not prewired; if
prewiring for the motorized operating mechanism is
wanted, please specify "L12" in addition.
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

available with
VL160X, VL160, VL250
(3VL1, 3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M4 2

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M6 0

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M1 1

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

M2 2

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

Additional price

Siemens LV 10.1 2011

2/55

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Options
When ordering, add "-Z" to the complete Order No. and add the
relevant order code(s).

Order No. with "-Z"


1234 5 6 7

8 9 10 11 12

13 14 15 16

Additional
price

3VL . . . . - . . . . . - . . . . -Z
and additional order code(s)
@@@

+...+...
Code for
further versions -Z

For fixed-mounted circuit breakers (wired in factory)


Pre-mounted motorised operating mechanisms
(24 V DC) on circuit breaker,
not synchronizable
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

Available with
VL160X
(3VL1)

M2 5

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

Available with
VL160X
(3VL1)

M4 3

Additional price

2/56

Siemens LV 10.1 2011

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

Available with
VL160X
(3VL1)

M1 2

VL160, VL250
(3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

VL1250, VL1600 (3VL7, 3VL8) )


Pre-mounted motorized operating mechanisms
(220 ... 250 V AC/DC ) on circuit breakers,
not synchronizable
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

VL160, VL250
(3VL2, 3VL3)

VL1250, VL1600 (3VL7, 3VL8)


Pre-mounted motorized operating mechanisms
(110 ... 127 V AC/DC ) on circuit breakers,
not synchronizable
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

VL160, VL250
(3VL2, 3VL3)

VL1250, VL1600 (3VL7, 3VL8)


Pre-mounted motorized operating mechanisms
(42 ... 60 V AC/DC ) on circuit breakers,
not synchronizable
If internal accessories are provided, the prewiring
option "L02" for internal accessories is already
included. In this case "L02" must not be specified in
addition.

Available with
VL160X
(3VL1)

M2 3

VL160, VL250
(3VL2, 3VL3)

VL400 (3VL4)

VL630, VL800 (3VL5, 3VL6)

VL1250, VL1600 (3VL7, 3VL8)

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Options
1. Order No. supplement:
Undervoltage or shunt release,
wiring directly to accessories
Rated control supply voltage Us/
Frequency

Order No. supplement Circuit breakers

50/60 Hz AC
DC

3VL . . . . - . . . . . -

Type

Without auxiliary release

@@

.. VL160X to VL400/
3VL1 to 3VL4

VL630 to VL1600/
3VL5 to 3VL8

Additional price

Additional price

0 A

None

None

2 N
2 P
2 U

With undervoltage releases


Only right pole
V AC
----

V DC
12
24
48

----

60
110 ... 127
220 ... 250

2 V
2 R
2 S

24
110 ... 127
220 ... 250

----

2 D
2 G
2 H

208
277

---

2 M
2 Q

380 ... 415


440 ... 480
500 ... 525

----

2 J
2 K
2 L

With shunt releases


Only right pole
V AC

V DC

24
----

24
48 ... 60
110 ... 127
220 ... 250

8
8
8
8

C
J
K
Q

48 ... 60
110 ... 127
208 ... 277
380 ... 600

-----

8
8
8
8

M
R
T
V

2. Order No. supplement:


Auxiliary switches (HS) and alarm switches (AS),
left/right pole,
directly wired to accessories
Equipment

Order No. supplement

HS = 1 NO or 1 NC switching block
AS = 1 NO switching block

3VL . . . . - . . . . . - ..

Circuit breakers
Type

@@

VL160X to VL4001)/
3VL1 to 3VL4
Additional price

Without auxiliary/alarm switches

A 0 None

2 HS (1 NO/1 NC)2)
4 HS (2 NO/2 NC)
2 HS (1 NO/1 NC) + 1 AS (1 NO)
2 HS (1 NO/1 NC) + 1 AS (1 NO)3)

B
C
D
E

1
1
1
1

-
--

VL630 to VL1600/
3VL5 to 3VL8
Additional price
None

1)4)
1)4)

-
-

5)

Additional price
-- Not available
1)

Except for installing in the left accessory compartment of the SENTRON


VL160X circuit breakers with RCD module.

2)

With mounting adapter up to 3 HS.

3)

With mounting adapter up to 2 HS + 2 AS.

4)

Not feasible for use of SENTRON VL160 and VL250 with LCD ETU or
marine engineering ETU and additional use of shunt and undervoltage
releases.
When using a communication-capable ETU, the accessory compartment
X2 is fitted with an auxiliary switch and an alarm switch. The combination of
1st and 2nd Order No. supplement is only possible with restrictions. It is
recommended to use the configurator in the Mall for selection purposes.

5)

Not possible when using a communication-capable ETU.

Siemens LV 10.1 2011

2/57

Siemens AG 2011

Molded Case Circuit Breakers


Options
Equipment options for the insulated accessory subsections in the SENTRON 3VL circuit breakers

X2:
left accessories
compartment
selectable:
VL160X
3VL1

Max.
3 HS

VL160
3VL2

Max.
3 HS

VL250
3VL3

Max.
3 HS

VL400
3VL4

Max.
3 HS

VL630
3VL5

Max.
4 HS

VL800
3VL6

Max.
4 HS

VL1250
3VL7

Max.
4 HS

VL1600
3VL8

Max.
4 HS

ETU marine
engineering-certified:
Left accessories compartment is fitted with
tripping solenoid

X1:
right accessories
compartment
selectable:
Max.
2 HS +
1 AS
Max.
2 HS +
1 AS
Max.
2 HS +
1 AS
Max.
2 HS +
1 AS
Max.
2 HS +
2 AS
Max.
2 HS +
2 AS
Max.
2 HS +
2 AS
Max.
2 HS +
2 AS

VL160X with RCD:


Left accessories
compartment is fitted with
tripping solenoid

U<

Max.
3 HS

U<

Max.
3 HS

U<

Max.
3 HS

U<

Max.
2 HS +
1 AS
Max.
2 HS +
1 AS
Max.
2 HS +
1 AS

Max.
3 HS

Max.
3 HS

Max.
3 HS

VL250
3VL3

Max.
3 HS

Max.
3 HS

VL400
3VL4

Max.
3 HS

Max.
3 HS

VL630
3VL5

Max.
4 HS

Max.
4 HS

U<

Max.
4 HS

VL1250
3VL7

Max.
4 HS

Max.
4 HS

U<

Max.
4 HS

VL1600
3VL8

Max.
4 HS

Max.
4 HS

U<

Max.
4 HS

ETU marine
engineering-certified:
Left accessories
compartment is fitted
with tripping solenoid

X1:
Right accessory
compartment
selectable:

U<

Max.
3 HS

VL250
3VL3

Max.
1 HS

U<

Max.
3 HS

VL400
3VL4

Max.
1 HS

U<

VL1600
3VL8

VL160
3VL2

Max.
4 HS

Max.
1 HS

VL1250
3VL7

Max.
3 HS

Max.
4 HS

VL160
3VL2

VL800
3VL6

Max.
3 HS

VL800
3VL6

Shunt release or
undervoltage release
HS one auxiliary switch 1 NO or 1 NC
AS one alarm switch 1 NO or 1 NC

Max.
1 HS +
1 AS
Max.
1 HS +
1 AS
Max.
1 HS +
1 AS
Max.
1 HS +
1 AS

VL160X
3VL1

Max.
4 HS

3-pole circuit breakers with communication preparation

VL630
3VL5

Max.
2 HS +
1 AS
Max.
2 HS +
1 AS

Max.
2 HS+
1 AS
Max.
2 HS+
1 AS
Max.
2 HS+
1 AS
Max.
2 HS+
1 AS
Max.
2 HS+
2 AS
Max.
2 HS+
2 AS
Max.
2 HS+
2 AS
Max.
2 HS+
2 AS

VL160X with RCD:


Left accessories
compartment is fitted
with tripping solenoid

U<

Max.
3 HS

U<

Max.
3 HS

U<

Max.
3 HS

U<

Max.
3 HS

U<

Max.
4 HS

U<

Max.
4 HS

U<

Max.
4 HS

U<

Max.
4 HS

Max.
2 HS+
1 AS
Max.
2 HS+
1 AS
Max.
2 HS+
1 AS

Shunt release or
U<
undervoltage release
HS one auxiliary switch 1 NO or 1 NC
AS one alarm switch 1 NO or 1 NC
Note:
Maximum 6 switch elements (HS) per
circuit breaker VL160X to VL400
Maximum 8 switch elements (HS) per
circuit breaker VL630 to VL1600

4-pole circuit breakers with communication preparation

X4:
N 4th pole
accessory
compartment

X2:
Left accessory
compartment
selectable:

X1:
Right accessory
compartment
selectable:

VL160
3VL2

Max.
3 HS

Max.
1 HS

U<

Max.
3 HS

VL250
3VL3

Max.
3 HS

Max.
1 HS

U<

Max.
3 HS

Max.
3 HS

VL400
3VL4

Max.
3 HS

Max.
1 HS

U<

Max.
3 HS

U<

Max.
4 HS

VL630
3VL5

Max.
4 HS

U<

Max.
4 HS

U<

Max.
4 HS

VL800
3VL6

Max.
4 HS

U<

Max.
4 HS

U<

Max.
4 HS

VL1250
3VL7

Max.
4 HS

U<

Max.
4 HS

U<

Max.
4 HS

VL1600
3VL8

Max.
4 HS

U<

Max.
4 HS

NSE0_02115

When using a communication-capable ETU,


the accessory compartment X2 is fitted with
an auxiliary switch and an alarm switch

X1: right
accessories
compartment
selectable:

X2: left
accessories
compartment
selectable:

X4: N - 4 pole
accessories
compartment

U<

U<

X2:
Left accessory
compartment
selectable:

4-pole circuit breakers without communication preparation

NSE0_02116a

3-pole circuit breakers without communication preparation

NSE0_02114a

3VL Molded Case Circuit Breakers up to 1600 A

Max.
1 HS +
1 AS
Max.
1 HS +
1 AS
Max.
1 HS +
1 AS
Max.
1 HS +
1 AS

Max.
2 HS +
1 AS
Max.
2 HS +
1 AS

NSE0_02117

Shunt release or
undervoltage release
HS one auxiliary switch 1 NO or 1 NC
AS one alarm switch 1 NO or 1 NC
U<

When using a communication-capable ETU,


the accessory compartment X2 is fitted with
an auxiliary switch and an alarm switch

Shunt release or
undervoltage release
HS one auxiliary switch 1 NO or 1 NC
AS one alarm switch 1 NO or 1 NC
U<

Note:
Before ordering, use the tables above to check whether the
required combination of shunt releases, undervoltage releases
and auxiliary/alarm switches is feasible.

2/58

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts

Selection and ordering data


Wiring directly at accessories

DT

For VL160X to VL400


(3VL1 to 3VL4)
Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Auxiliary switches and auxiliary releases


3- or 4-pole
For retrofitting (for possible complements see Technical Information at
www.siemens.com/lowvoltage/support.)
Auxiliary switches (HS) and alarm switches (AS)
For retrofitting

NSE0_00684

Assembly kits

Mounting side

2 HS (1 NO + 1 NC)

N, left1), right

4 HS (2 NO + 2 NC)

N, left1), right

2 HS (1 NC + 1 NO)

left1), right3)

+ 1 AS (1 NO)
(assembly kit)

left1)

1 unit

113

0.027

1 unit

113

0.051

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.075
0.075
0.075

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.075
0.075
0.075

1
1

1 unit
1 unit

113
113

0.075
0.075

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

0.075
0.075
0.075
0.075
0.075

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.075
0.075
0.075
0.075

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.075
0.075
0.075

1
1

1 unit
1 unit

113
113

0.075
0.075

-A

3VL9 400-2AD00
--

Additional auxiliary switch/alarm switch combinations


3VL9 400-2A.00

3VL9 400-2AB00

See page 2/61.

Shunt releases 2)
For retrofitting
V AC
24
--

V DC

Mounting side

24
48 ... 60

Right pole only


Right pole only

A
A

3VL9 400-1SC00
3VL9 400-1SJ00

--48 ... 60

110 ... 127


220 ... 250
--

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 400-1SK00
3VL9 400-1SQ00
3VL9 400-1SM00

110 ... 127


208 ... 277
380 ... 600

----

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 400-1SR00
3VL9 400-1ST00
3VL9 400-1SV00

NSE0_00678

Undervoltage release
For retrofitting

3VL9 400-1S.00,
3VL9 400-1U.00

V AC
-----

V DC

Mounting side

12
24
48
60

Right pole only


Right pole only
Right pole only
Right pole only

A
A
A
A

3VL9 400-1UN00
3VL9 400-1UP00
3VL9 400-1UU00
3VL9 400-1UV00

24
110 ... 127
-208

--110 ... 127


--

Right pole only


Right pole only
Right pole only
Right pole only

A
A
A
A

3VL9 400-1UD00
3VL9 400-1UG00
3VL9 400-1UR00
3VL9 400-1UM00

220 ... 250


-277

-220 ... 250


--

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 400-1UH00
3VL9 400-1US00
3VL9 400-1UQ00

380 ... 415


440 ... 480
500 ... 525

----

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 400-1UJ00
3VL9 400-1UK00
3VL9 400-1UL00

3TX4 701-0AN1

1 unit

101

0.170

3WL9 111-0BA14-0AA0

1 unit

103

0.520

Time-delay devices for undervoltage releases


(220 ... 250 V DC)
Rated control supply voltage Us
220 ... 250 V AC
Delay time > 200 ms
Storage devices for shunt releases
(208 ... 277 V AC/220 ... 250 V DC)
Rated control supply voltage Us
220 ... 240 V AC/ 220 ... 250 V DC
Storage time 5 min
1)

Except for installing in the left accessory compartment of the SENTRON


VL160X (3VL1) circuit breakers with RCD module and SENTRON
VL160/250 with LCD ETU.

2)

Shunt releases with disconnection contact (3SB3 for ON/OFF position)


not floating (see Technical Information at
www.siemens.com/lowvoltage/support).

3)

In the case of VL400 (3VL4):


Unsuitable for mounting in the right-hand accessory compartment.
The 3VL9 400-2AB00 assembly kit with auxiliary switches only is recommended.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/59

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Wiring directly at accessories

DT

For VL630 up to VL1600


(3VL5 to 3VL8)
Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Auxiliary switches and auxiliary releases


3- or 4-pole
For retrofitting (for possible complements see Technical Information at
www.siemens.com/lowvoltage/support.)
Auxiliary switches (HS) and
alarm switches (AS)
For retrofitting

NSE0_00684

3VL9 800-2A.00

Assembly kits

Mounting side

2 HS (1 NO + 1 NC)

N, left, right

4 HS (2 NO + 2 NC)

N, left, right

2 HS (1 NC + 1 NO)

Left, right

+ 1 AS (1 NO)
(assembly kit)

Left

-A

3VL9 800-2AC00

1 unit

113

0.058

1 unit

113

0.060

-A

Additional auxiliary switch/alarm switch combinations

3VL9 800-2AE00
See page 2/61.

Shunt releases 1)
For retrofitting
V AC
24
--

V DC

Mounting side

24
48 ... 60

Right pole only


Right pole only

A
A

3VL9 800-1SC00
3VL9 800-1SJ00

1
1

1 unit
1 unit

113
113

0.120
0.120

--48 ... 60

110 ... 127


220 ... 250
--

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 800-1SK00
3VL9 800-1SQ00
3VL9 800-1SM00

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.120
0.120
0.120

110 ... 127


208 ... 277
380 ... 600

----

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 800-1SR00
3VL9 800-1ST00
3VL9 800-1SV00

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.120
0.120
0.120

Undervoltage release
For retrofitting
NSE0_00678

3VL Molded Case Circuit Breakers up to 1600 A

V AC
-----

3VL9 800-1S.00,
3VL9 800-1U.00

V DC

Mounting side

12
24
48
60

Right pole only


Right pole only
Right pole only
Right pole only

A
A
A
A

3VL9 800-1UN00
3VL9 800-1UP00
3VL9 800-1UU00
3VL9 800-1UV00

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.088
0.088
0.088
0.088

24
110 ... 127
-208

--110 ... 127


--

Right pole only


Right pole only
Right pole only
Right pole only

A
A
A
A

3VL9 800-1UD00
3VL9 800-1UG00
3VL9 800-1UR00
3VL9 800-1UM00

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.088
0.088
0.088
0.088

220 ... 250


-277

-220 ... 250


--

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 800-1UH00
3VL9 800-1US00
3VL9 800-1UQ00

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.088
0.088
0.088

380 ... 415


440 ... 480
500 ... 525

----

Right pole only


Right pole only
Right pole only

A
A
A

3VL9 800-1UJ00
3VL9 800-1UK00
3VL9 800-1UL00

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.088
0.088
0.088

3TX4 701-0AN1

1 unit

101

0.170

3WL9 111-0BA14-0AA0

1 unit

103

0.520

Time-delay devices for undervoltage releases


(220 ... 250 V DC)
Rated control supply voltage Us
220 ... 250 V AC
Delay time > 200 ms
Storage devices for shunt releases
(208 ... 277 V AC/220 ... 250 V DC)
Rated control supply voltage Us
220 ... 240 V AC/ 220 ... 250 V DC
Storage time 5 min
1)

Shunt releases with disconnection contact (3SB3 for ON/OFF position)


not floating (see Technical Information at
www.siemens.com/lowvoltage/support).

* You can order this quantity or a multiple thereof.

2/60

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
For circuit
breakers

Maximum combination of
auxiliary switches (HS) and
alarm switches (AS)

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Type

3SB adapters and 3SB contact blocks


Mounting adapters for auxiliary and alarm switch combinations
For installation in the N pole of the circuit breaker
VL160X,
VL160,
VL250,
VL400 (3VL1 to 3VL4)
VL630,
VL800,
VL1250,
VL1600 (3VL5 to 3VL8)

Up to 3 HS1)

1) 2)

2 HS + 1 AS
Up to 4 HS

3VL9 400-2AH00

1 unit

113

0.009

1 unit

113

0.075

-A

2 HS + 2 AS

3VL9 816-2AL00
--

For installation in the left pole of the circuit breaker


VL160X,
VL160,
VL250,
VL400 (3VL1 to 3VL4)
VL630,
VL800,
VL1250,
VL1600 (3VL5 to 3VL8)

Up to 3 HS1)

3VL9 400-2AH00

1 unit

113

0.009

2 HS + 1 AS

3VL9 400-2AJ10

1 unit

113

0.001

Up to 4 HS

3VL9 816-2AL00

1 unit

113

0.075

2 HS + 2 AS

3VL9 816-2AN10

1 unit

113

0.072

Up to 3 HS1)

3VL9 400-2AH00

1 unit

113

0.009

2 HS + 1 AS1) 2)

3VL9 400-2AJ20

1 unit

113

0.001

Up to 4 HS

3VL9 816-2AL00

1 unit

113

0.075

1) 2)

For installation in the right pole of the circuit breaker


VL160X,
VL160,
VL250,
VL400 (3VL1 to 3VL4)2)
VL630,
VL800,
VL1250,
VL1600 (3VL5 to 3VL8)
1)

2 HS + 2 AS

--

Except for installing in the left pole for SENTRON VL160X circuit breakers
(3VL1) with RCD module.

For auxiliary/alarm switches

DT

2)

In the case of VL400: 3VL9 400-2AJ20 unsuitable for mounting in the righthand accessory sub-section.

Circuit breakers
Type
VL160X to VL1600 (3VL1 to 3VL8)
Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.

kg

Switching blocks for auxiliary and alarm switch combinations


1 NO

3SB34 00-0J

1 unit

102

0.010

1 NC

3SB34 00-0K

1 unit

102

0.010

For auxiliary switch or alarm switch combinations not included in


the kits provided as standard, the mounting adapters specified
can be ordered separately together with the required contact
blocks:
1 HS or 1 AS with NO contact 3SB34 00-0J
1 HS or 1 AS with NC contact 3SB34 00-0K

Note:
A maximum of 6 contact blocks (HS) per circuit breaker
(VL160X, VL160, VL250, VL400; 3VL1 to 3VL4) and a maximum
of 8 contact blocks (HS) per circuit breaker (VL630, VL800,
VL1250, VL1600; 3VL5 to 3VL8) are possible.
Four 3SB34 auxiliary contact blocks and one mounting adapter
(right), suitable for VL630, VL800, VL1250, VL1600 (3VL5 to
3VL8) circuit breakers.

NSE0_00684

For retrofitting/possible complement see Technical Information


at www.siemens.com/lowvoltage/support.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/61

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL160X to VL250


(3VL1 to 3VL3)
Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Operating mechanisms
3- or 4-pole
NSE0_00679

Front-operated rotary operating mechanisms1)


For direct mounting on the circuit breaker,
without leading auxiliary switch, degree of
protection IP302), black, max. 3 padlocks

3VL9 300-3HA00

1 unit

113

0.362

3VL9 300-3HC00

1 unit

113

0.362

3VL9 300-3HE00

1 unit

113

0.267

Door-coupling rotary operating mechanisms,


complete1)
Installation in doors and covers
Degree of protection IP65, including handle ti-grey,
with masking plate, indicator plate, detachable door
coupling (die cast with reduced tolerance compensation), extension shaft (8 8 mm), length 300 mm
and front-operated rotary operating mechanism for
the respective circuit breaker, lockable with up to
3 padlocks, with door interlocking
A

3VL9 300-3HF05

1 unit

113

0.970

3VL9 300-3HG05

1 unit

113

0.980

1 changeover contact with 1.5 m long cables

3VL9 300-3AS10

1 unit

113

0.080

2 changeover contacts with 1.5 m long cables

3VL9 300-3AT10

1 unit

113

0.130

1 changeover contact with 1.5 m long cables

3VL9 300-3AU10

1 unit

113

0.080

2 changeover contacts with 1.5 m long cables

3VL9 300-3AW10

1 unit

113

0.130

- With 600 mm Bowden wire

3VL9 300-3HR10

1 unit

113

1.400

- With 1000 mm Bowden wire

3VL9 300-3HR20

1 unit

113

1.400

- With 1500 mm Bowden wire

3VL9 300-3HR30

1 unit

113

1.400

- With 600 mm Bowden wire

3VL9 300-3HR11

1 unit

113

1.400

- With 1000 mm Bowden wire

3VL9 300-3HR21

1 unit

113

1.400

- With 1500 mm Bowden wire

3VL9 300-3HR31

1 unit

113

1.400

Retaining bracket is mounted on the operating


X
mechanism, recommended for extension shafts
>250 mm, with locking device for max. 3 padlocks

3VL9 300-3HP02

1 unit

113

0.435

3VL9 300-3HP00

1 unit

113

0.253

EMERGENCY-STOP version
Red knob, yellow indicator plate

3VL9 .00-3H.00

Safety locks for installation by the customer


For installation see pages 2/84 to 2/88.
Front rotary operating mechanisms
with shaft end, without knob1)
Without leading auxiliary switch,
for auxiliary switches see below

NSE0_00711

3VL9 .00-3H.05

EMERGENCY-STOP version
Red knob, yellow indicator plate,
without leading auxiliary switch
Safety locks for installation by the customer
For installation see pages 2/84 to 2/88.

NSE0_00712

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 .00-3A.10

Leading auxiliary switches


For installation in a front-operated rotary
operating mechanism, door-coupling rotary
operating mechanism or side panel rotary
operating mechanism
Standard or EMERGENCY-STOP version
"OFF after ON"
Leading auxiliary switches when switching on

"ON after OFF"


Leading auxiliary switches when switching off

Side panel rotary operating mechanisms,


complete1)
Degree of protection IP65, including black knob
with masking plate, indicator plate, Bowden wire,
lockable with up to 3 padlocks

Side panel rotary operating mechanisms,


complete1)
EMERGENCY-STOP version
Degree of protection IP65, including red knob with
masking plate, yellow indicator plate, Bowden wire,
lockable with up to 3 padlocks

Retaining brackets,
suitable for matching door-coupling rotary
operating mechanisms, complete

- for 6 mm shaft

Additional accessories and components for door-coupling rotary operating mechanism, see 2/67 and 2/69.

A
1)

Not possible on VL160X with RCD module.

2)

IP40 with additional masking frame mounted on the door cutout.


* You can order this quantity or a multiple thereof.

2/62

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL400 (3VL4)


Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

Weight DT For VL630 (3VL5)


per PU
approx.
Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

3VL9 400-3HA00

1 unit

113

0.725 A

3VL9 600-3HA00

1 unit

113

0.834

3VL9 400-3HC00

1 unit

113

0.725 A

3VL9 600-3HC00

1 unit

113

0.834

3VL9 400-3HE00

1 unit

113

0.267 A

3VL9 600-3HE00

1 unit

113

0.755

3VL9 400-3HF05

1 unit

113

0.970 A

3VL9 600-3HF05

1 unit

113

2.465

3VL9 400-3HG05

1 unit

113

1.100 A

3VL9 600-3HG05

1 unit

113

2.460

3VL9 400-3AS10

1 unit

113

0.080 A

3VL9 600-3AS10

1 unit

113

0.080

3VL9 400-3AT10

1 unit

113

0.130 A

3VL9 600-3AT10

1 unit

113

0.130

3VL9 400-3AU10

1 unit

113

0.080 A

3VL9 600-3AU10

1 unit

113

0.080

3VL9 400-3AW10

1 unit

113

0.130 A

3VL9 600-3AW10

1 unit

113

0.130

3VL9 400-3HR10

1 unit

113

2.000 A

3VL9 500-3HR10

1 unit

113

2.400

3VL9 400-3HR20

1 unit

113

2.000 A

3VL9 500-3HR20

1 unit

113

2.400

3VL9 400-3HR30

1 unit

113

2.000 A

3VL9 500-3HR30

1 unit

113

2.400

3VL9 400-3HR11

1 unit

113

2.000 A

3VL9 500-3HR11

1 unit

113

2.400

3VL9 400-3HR21

1 unit

113

2.000 A

3VL9 500-3HR21

1 unit

113

2.400

3VL9 400-3HR31

1 unit

113

2.000 A

3VL9 500-3HR31

1 unit

113

2.400

3VL9 400-3HP00

1 unit

113

0.379 A

3VL9 600-3HP00

1 unit

113

0.437

--

--

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/63

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL800 (3VL6)


Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Operating mechanisms

NSE0_00679

3- or 4-pole

3VL9 .00-3H.00

Front-operated rotary operating mechanisms


For direct mounting on the circuit breaker,
without leading auxiliary switch,
degree of protection IP301), black,
max. 3 padlocks
A

3VL9 600-3HA00

1 unit

113

0.834

EMERGENCY-STOP version
Red knob, yellow indicator plate

3VL9 600-3HC00

1 unit

113

0.834

3VL9 600-3HE00

1 unit

113

0.755

Door-coupling rotary operating mechanisms,


complete, installation in doors and covers
Degree of protection IP65, including handle,
ti-grey, with masking frame, indicator plate,
detachable door coupling (die cast, for VL800
(3VL6) with reduced tolerance compensation),
extension shaft (8 8 mm for VL800 (3VL6),
12 12 mm for VL1250 (3VL7) and VL1600
(3VL8), length 300 mm and front rotary operating
mechanism for the respective circuit breaker,
lockable with max. 3 padlocks, with door
interlocking
A

3VL9 600-3HF05

1 unit

113

2.465

3VL9 600-3HG05

1 unit

113

2.460

1 changeover contact with 1.5 m long cables

3VL9 600-3AS10

1 unit

113

0.080

2 changeover contacts with 1.5 m long cables

3VL9 600-3AT10

1 unit

113

0.130

1 changeover contact with 1.5 m long cables

3VL9 600-3AU10

1 unit

113

0.080

2 changeover contacts with 1.5 m long cables

3VL9 600-3AW10

1 unit

113

0.130

3VL9 600-3HP00

1 unit

113

0.437

Safety locks for installation by the customer


For installation see pages 2/84 to 2/88.
Front rotary operating mechanisms
with shaft stub, without knob
Without leading auxiliary switch,
for auxiliary switches see below

NSE0_00711

3VL9 .00-3H.05

EMERGENCY-STOP version,
Red knob, yellow indicator plate,
without leading auxiliary switch
Safety locks for installation by the customer
For installation see pages 2/84 to 2/88.

NSE0_00712

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 .00-3A.10

Leading auxiliary switches


For installation in a front-operated rotary
operating mechanism or door-coupling rotary
operating mechanism
Standard or EMERGENCY-STOP version
"OFF after ON"
Leading auxiliary switches when switching on

"ON after OFF"


Leading auxiliary switches when switching off

Retaining brackets
suitable for matching door-coupling rotary
operating mechanisms, complete
Retaining bracket is mounted on the operating
mechanism, recommended for extension shafts
>250 mm, with locking device for max. 3 padlocks

Additional accessories and components for door-coupling rotary operating mechanism, see 2/67 and 2/69.

1)

IP40 with additional masking frame mounted on the door cutout.

* You can order this quantity or a multiple thereof.

2/64

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL1250 to VL1600


(3VL7 to 3VL8)
Order No.

PU
(UNIT,
Price SET, M)
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3VL9 800-3HA00

1 unit

113

2.831

3VL9 800-3HC00

1 unit

113

2.831

3VL9 800-3HE00

1 unit

113

2.175

3VL9 800-3HF05

1 unit

113

4.102

3VL9 800-3HG05

1 unit

113

4.100

3VL9 800-3AS20

1 unit

113

0.080

3VL9 800-3AT20

1 unit

113

0.130

3VL9 800-3AU10

1 unit

113

0.080

3VL9 800-3AW10

1 unit

113

0.130

3VL9 800-3HP00

1 unit

113

0.529

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/65

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

NSE0_00716

Motorized operating mechanisms


3- or 4-pole

3VL9 .00-3M.00

Motorized operating mechanisms


with stored energy mechanisms
for synchronization tasks1)2)
Degree of protection IP30, with locking device for
3 padlocks
50/60 Hz V AC

V DC

-42 ... 48
60
110 ... 127
220 ... 250

24
42 ... 48
60
110 ... 127
220 ... 250

For VL160X to VL250


(3VL1 to 3VL3)

A
A
A
A
A

Toggle handle extensions

3VL9 300-3MJ00
3VL9 300-3ML00
3VL9 300-3MS00
3VL9 300-3MN00
3VL9 300-3MQ00

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

2.140
2.140
2.140
2.140
2.140

-For VL400 (3VL4)

50/60 Hz V AC

V DC

-42 ... 48
60
110 ... 127
220 ... 250

24
42 ... 48
60
110 ... 127
220 ... 250

Toggle handle extensions

A
A
A
A
A

3VL9 400-3MJ00
3VL9 400-3ML00
3VL9 400-3MS00
3VL9 400-3MN00
3VL9 400-3MQ00

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

3.910
3.910
3.910
3.910
3.910

3VL9 400-3HN00

1 unit

113

0.100

For VL630 to VL800


(3VL5 to 3VL6)
50/60 Hz V AC

V DC

-42 ... 48
60
110 ... 127
220 ... 250

24
42 ... 48
60
110 ... 127
220 ... 250

Toggle handle extensions


Motorized operating mechanisms2)
Degree of protection IP30, with locking
device for 3 padlocks
16(B

3VL Molded Case Circuit Breakers up to 1600 A

50/60 Hz V AC

V DC

-42 ... 60
110 ... 127
220 ... 250

24
42 ... 60
110 ... 127
220 ... 250

A
A
A
A
A

3VL9 600-3MJ00
3VL9 600-3ML00
3VL9 600-3MS00
3VL9 600-3MN00
3VL9 600-3MQ00

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

113
113
113
113
113

4.800
4.800
4.800
4.800
4.800

3VL9 600-3HN00

1 unit

113

0.140

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.000
1.000
1.000
1.000

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.000
1.000
1.000
1.000

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.000
1.000
1.000
1.000

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.000
1.000
1.000
1.000

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.000
1.000
1.000
1.000

For VL160X (3VL1)

B
B
B
B

3VL9 100-3MA10
3VL9 100-3MC10
3VL9 100-3MD10
3VL9 100-3ME10
For VL160 and VL250
(3VL2 and 3VL3)

3VL9 .00-3M.10
50/60 Hz V AC

V DC

-42 ... 60
110 ... 127
220 ... 250

24
42 ... 60
110 ... 127
220 ... 250

50/60 Hz V AC

V DC

-42 ... 60
110 ... 127
220 ... 250

24
42 ... 60
110 ... 127
220 ... 250

B
B
B
B

3VL9 300-3MA10
3VL9 300-3MC10
3VL9 300-3MD10
3VL9 300-3ME10
For VL400 (3VL4)

B
B
B
B

3VL9 400-3MA10
3VL9 400-3MC10
3VL9 400-3MD10
3VL9 400-3ME10
For VL630 and VL800
(3VL5 and 3VL6)

50/60 Hz V AC

V DC

-42 ... 60
110 ... 127
220 ... 250

24
42 ... 60
110 ... 127
220 ... 250

B
B
B
B

3VL9 600-3MA10
3VL9 600-3MC10
3VL9 600-3MD10
3VL9 600-3ME10
For VL1250 and VL1600 (3VL7
and 3VL8)

50/60 Hz V AC

V DC

-42 ... 60
110 ... 127
220 ... 250

24
42 ... 60
110 ... 127
220 ... 250

1)

Not possible on VL160X with RCD module.

2)

For safety lock as an assembly kit for retrofitting see pages 2/84 to 2/88.

B
B
B
B

3VL9 800-3MA10
3VL9 800-3MC10
3VL9 800-3MD10
3VL9 800-3ME10

* You can order this quantity or a multiple thereof.

2/66

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
Switching
device

Rotary Size
operating
mechanisms

Cross-section Version3)
of the actuating shaft

DT

Individual parts for 8UC7


door-coupling rotary operating
mechanisms

Order No.
Type

Type

mm mm

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Price
per PU
kg

Individual parts for 8UC door-coupling rotary operating mechanisms


Handles with masking plate
(including flat gasket and fixing screws)
3VL1,
Standard
8UC71 1
66
3VL2,
EMERor
3VL3
GENCY88
STOP

C
C

8UC71 10-6BD
8UC71 20-8BD

1
1

1 unit
1 unit

103
103

0.200
0.200

8UC71 10-1BB
3VL4,
3VL5,
3VL6

8UC72 2

88

Standard
EMERGENCYSTOP

C
C

8UC72 10-6BD
8UC72 20-8BD

1
1

1 unit
1 unit

103
103

0.200
0.200

3VL7,
3VL8

8UC73 3

12 12

Standard
EMERGENCYSTOP

C
C

8UC73 10-6BD
8UC73 20-8BD

1
1

1 unit
1 unit

103
103

0.200
0.200

DT

Individual parts for 8UC6


door-coupling rotary operating
mechanisms

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

8UC72 10-6BD

8UC73 10-1BB
Rotary operating mechanisms

Cross-section
of the actuating shaft

Type

mm mm

Order No.

Price
per PU

kg

Individual parts for 8UC door-coupling rotary operating mechanisms


Coupling drivers for 3VL
8UC71 (plastic)
8UC71/8UC722) (die cast)
8UC73/74 (die cast)

66
88
12 12

C
A
B

8UC70 11-2AA
8UC60 17-2AA
8UC60 14

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.200
0.047
0.253

Extension shafts 300 mm long


8UC71
8UC71/8UC72
8UC73
8UC73/74

66
88
10 10
12 12

B
B
C
B

8UC60 31
8UC60 32
8UC60 33
8UC60 34

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.068
0.132
0.217
0.315

Extension shafts 600 mm long


8UC71
8UC71/8UC72
8UC73
8UC73/74

66
88
10 10
12 12

B
B
B
B

8UC60 81
8UC60 82
8UC60 83
8UC60 84

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.136
0.265
0.430
0.640

Shaft couplings
8UC71
8UC72
8UC73
8UC73/74

66
88
10 10
12 12

B
B
B
B

8UC60 21
8UC60 22
8UC60 23
8UC60 24

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.031
0.023
0.085
0.077

8 8 to 6 6
12 12 to
88

C
C

8UC70 58
8UC70 50

1
1

1 unit
1 unit

103
103

0.200
0.200

Rivet

nse0_00372

8UC60 14

NSE0_00373

Groove
8UC60 31

NSE0_00373

Groove
8UC60 81

nse0_00374

Lug Rivet
8UC60 21 to 8UC60 24
Reducers
8UC71
8UC72
ns

g0

_0

02

44

8UC70 58
1)

Non-interchangeability features.

2)

Shortened coupling driver with reduced tolerance compensation.

3)

Standard: Ti-grey handle, light-gray masking plate;


EMERGENCY-STOP: Red handle, yellow masking plate.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/67

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Switching device

Rated current Cross-section of


the actuating
shaft

Torque

Rotary
operating
mechanisms

Type

mm

Nm

Size

3VL1

16 ... 160

66

3VL2

50 ... 160

66

3VL3

200... 250

66

Illustrated:
Handle, masking plate

8UC Door-Coupling Rotary Operating Mechanisms


8UC71 - 3VL circuit breakers
75
NSE00362

Tripped

Reset

36

16 ... 160

88

3VL2

50 ... 160

88

3VL3

200 ... 250

88

75
Tripped

NSE00362

3VL1

(Supplied with door coupling rotary operating mechanism,


complete 3VL9 300-3H.05)

Reset

36

8UC72 - 3VL circuit breakers


200 ... 400

88

3VL5

315 ... 600

88

88

3VL6

320 ... 800

75
Tripped

NSE00363

3VL4

Reset

62

8UC73 - 3VL circuit breakers


3VL7

400 ... 1250

12 12

25

3VL8

640 ... 1600

12 12

25

100
Tripped

NSE00364

3VL Molded Case Circuit Breakers up to 1600 A

Reset

140
1)

Requires in addition a front-operated rotary operating mechanism with


shaft stub for direct mounting to the circuit breaker. For ordering the
complete operating mechanism see pages 2/62 to 2/65.

* You can order this quantity or a multiple thereof.

2/68

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
Version

DT Rotary operating mechanisms, PU


PS*/
PG
complete1)
(UNIT, P. unit
SET,
M)
Order No.

Standard:
Ti-grey handle,
light-gray
masking plate;

Price
per PU

Weight
per PU
approx.

Individual parts of the rotary operating mechanism

Handle with
masking plate

Coupling
drivers

Extension
shaft
(length
300 mm)

Reducer/
shaft coupling

Order No.

Order No.

Order No.

@ 6 mm

@ 6 mm

@ 8 mm by 6 mm

EMERGENCYSTOP:
Red handle,
yellow masking
plate
kg Order No.

Standard

8UC71 11-6BD15

1 unit 103

0.200 8UC71 10-6BD 8UC70 11-2AA 8UC60 31

8UC70 58

EMERGENCYSTOP

8UC71 21-8BD15

1 unit 103

0.200 8UC71 20-8BD 8UC70 11-2AA 8UC60 31

8UC70 58

Standard

8UC71 62-6BD22

1 unit 103

0.200 8UC71 10-6BD 8UC60 17-2AA 8UC60 32

8UC60 22

EMERGENCYSTOP

8UC71 72-8BD22

1 unit 103

0.200 8UC71 20-8BD 8UC60 17-2AA 8UC60 32

8UC60 22

Standard

8UC72 62-6BD26

1 unit 103

0.200 8UC72 10-6BD 8UC60 17-2AA 8UC60 32

8UC70 50

EMERGENCYSTOP

8UC72 62-8BD26

1 unit 103

0.200 8UC72 20-8BD 8UC60 17-2AA 8UC60 32

8UC70 50

@ 12 mm

@ 12 mm

@ 12 mm by 12 mm

Standard

8UC73 14-6BD44

1 unit 103

0.200 8UC73 10-6BD 8UC60 14

8UC60 34

8UC60 24

EMERGENCYSTOP

8UC73 24-8BD44

1 unit 103

0.200 8UC73 20-8BD 8UC60 14

8UC60 34

8UC60 24

(coupling driver
made of plastic)
@ 8 mm

@ 8 mm

@ 8 mm by 8 mm

(Die-cast
coupling driver
with reduced
tolerance
compensation)
@ 8 mm

@ 8 mm

@ 12 mm by 8 mm

(Die-cast
coupling driver
with reduced
tolerance
compensation)

(Die-cast
coupling driver)

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/69

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL160X (3VL1)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Plug-in versions/withdrawable versions


3- or 4-pole
Plug-in base assembly kits
Base, blade contacts for circuit breakers, terminal covers for degree of protection IP20, fixing
screws, trip pin
NSE0_00717

Rear terminals

3VL9 .00-4PA30

3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

A
A
A
A

3VL9 100-4PA30
3VL9 100-4PB30
3VL9 100-4PA40
3VL9 100-4PB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.170
2.460
2.850
3.200

A
A

3VL9 300-4PE30
3VL9 300-4PE40

1
1

1 unit
1 unit

113
113

0.375
0.500

A
A
A
A

3VL9 100-4PC30
3VL9 100-4PD30
3VL9 100-4PC40
3VL9 100-4PD40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.980
2.260
2.620
2.960

90 angle connecting adapters


For rear connection, 3-pole
For rear connection, 4-pole
Front-accessible terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

NSE00581

3VL9 .00-4PE30
Withdrawable version assembly kits
Upgrade of the plug-in base assembly kit to
Withdrawable version
including side panels
and racking mechanism.

3-pole
3-pole with RCD
4-pole
4-pole with RCD

-----

Withdrawable version
Same as plug-in base assembly kit, with additional side panels and racking mechanism

NSE0_00719

3VL9 .00-4WF30

NSE0_00683

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 .00-4WA30

Rear terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

-----

Front-accessible terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

-----

Blade contacts
As replacement for converting fixed-mounted
circuit breakers into plug-in/withdrawable circuit
breakers, including trip pin
1 set = 6 units
1 set = 8 units

3-pole
4-pole

A
A

3VL9 100-4PS30
3VL9 100-4PS40

1
1

1 unit
1 unit

113
113

0.226
0.295

3VL9 100-4PF00

1 unit

113

0.012

Trip pins and springs


As replacement for plug-in/withdrawable
circuit breaker
Auxiliary circuit plug connections for plug-in
bases
Accessory connections for plug-in circuit breakers (factory-wired connectors) and for plug-in
bases or withdrawable version (coupling with
screw terminal)

1)

1)

8 terminals

3VL9 300-4PJ00

1 unit

113

0.134

Position signaling switches


(connected/disconnected position)
For plug-in/withdrawable base, 1 CO,
max. 2 signaling switches possible

3VL9 000-4WL00

1 unit

113

0.019

It is recommended to use a maximum of 2 auxiliary circuit plug-in systems


per circuit breaker (16 terminals).

* You can order this quantity or a multiple thereof.

2/70

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL160 (3VL2)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL250 (3VL3)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

A
A
A
A

3VL9 200-4PA30
3VL9 200-4PB30
3VL9 200-4PA40
3VL9 200-4PB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.170
2.460
2.850
3.200

A
A
A
A

3VL9 300-4PA30
3VL9 300-4PB30
3VL9 300-4PA40
3VL9 300-4PB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.280
2.570
3.000
3.330

A
A

3VL9 300-4PE30
3VL9 300-4PE40

1
1

1 unit
1 unit

113
113

0.375 A
0.500 A

3VL9 300-4PE30
3VL9 300-4PE40

1
1

1 unit
1 unit

113
113

0.375
0.500

A
A
A
A

3VL9 200-4PC30
3VL9 200-4PD30
3VL9 200-4PC40
3VL9 200-4PD40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.980
2.260
2.620
2.960

A
A
A
A

3VL9 300-4PC30
3VL9 300-4PD30
3VL9 300-4PC40
3VL9 300-4PD40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

2.090
2.370
2.770
3.070

A
A
A
A

3VL9 300-4WF30
3VL9 300-4WG30
3VL9 300-4WF40
3VL9 300-4WG40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.260
2.031
1.280
2.050

A
A
A
A

3VL9 300-4WF30
3VL9 300-4WG30
3VL9 300-4WF40
3VL9 300-4WG40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.260
2.031
1.280
2.050

A
A
A
A

3VL9 200-4WA30
3VL9 200-4WB30
3VL9 200-4WA40
3VL9 200-4WB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

3.430
4.000
4.130
4.940

A
A
A
A

3VL9 300-4WA30
3VL9 300-4WB30
3VL9 300-4WA40
3VL9 300-4WB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

3.540
4.601
4.280
5.361

A
A
A
A

3VL9 200-4WC30
3VL9 200-4WD30
3VL9 200-4WC40
3VL9 200-4WD40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

3.240
3.810
3.940
4.710

A
A
A
A

3VL9 300-4WC30
3VL9 300-4WD30
3VL9 300-4WC40
3VL9 300-4WD40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

3.350
4.398
4.050
5.158

A
A

3VL9 200-4PS30
3VL9 200-4PS40

1
1

1 unit
1 unit

113
113

0.248 A
0.330 A

3VL9 300-4PS30
3VL9 300-4PS40

1
1

1 unit
1 unit

113
113

0.342
0.426

3VL9 300-4PF00

1 unit

113

0.013 A

3VL9 300-4PF00

1 unit

113

0.013

1)

1)

3VL9 300-4PJ00

1 unit

113

0.134 A

3VL9 300-4PJ00

1 unit

113

0.134

3VL9 000-4WL00

1 unit

113

0.019 A

3VL9 000-4WL00

1 unit

113

0.019

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/71

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL400 (3VL4)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Plug-in versions/withdrawable versions


3- or 4-pole
Plug-in base assembly kits
Base, blade contacts for circuit breakers, terminal covers for degree of protection IP20, fixing
screws, trip pin
NSE0_00717

Rear terminals

3VL9 .00-4PA30

3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

A
A
A

1 unit

113

5.869

1
1

1 unit
1 unit

113
113

8.008
10.100

3VL9 400-4PC30
--1)
3VL9 400-4PC40
3VL9 400-4PD40

1 unit

113

5.424

1
1

1 unit
1 unit

113
113

7.408
9.500

3VL9 400-4WF30
--1)
3VL9 400-4WF40
3VL9 400-4WG40

1 unit

113

3.400

1
1

1 unit
1 unit

113
113

3.600
3.800

3VL9 400-4WA30
--1)
3VL9 400-4WA40
3VL9 400-4WB40

1 unit

113

8.769

1
1

1 unit
1 unit

113
113

11.549
13.200

3VL9 400-4WC30
--1)
3VL9 400-4WC40
3VL9 400-4WD40

1 unit

113

8.324

1
1

1 unit
1 unit

113
113

10.949
12.600

3VL9 400-4PS30
3VL9 400-4PS40

1
1

1 unit
1 unit

113
113

0.720
0.960

3VL9 400-4PF00

1 unit

113

0.015

3VL9 400-4PA30
--1)
3VL9 400-4PA40
3VL9 400-4PB40

90 angle connecting adapters


For rear connection, 3-pole
For rear connection, 4-pole

---

Front-accessible terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

NSE00581

A
A
A

3VL9 .00-4PE30
Withdrawable version assembly kits
Upgrade of the plug-in base assembly kit to
Withdrawable version
including side panels
and racking mechanism.

3-pole
3-pole with RCD
4-pole
4-pole with RCD

A
A
A

Withdrawable version
Same as plug-in base assembly kit, with additional side panels and racking mechanism

NSE0_00719

3VL9 .00-4WF30

NSE0_00683

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 .00-4WA30

Rear terminals3)
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module
Front-accessible terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

A
A
A
A
A
A

Blade contacts
As replacement for converting fixed-mounted
circuit breakers into plug-in/withdrawable circuit
breakers, including trip pin
1 set = 6 units
3-pole
A
1 set = 8 units
4-pole
A
Trip pins and springs
As replacement for plug-in/withdrawable
circuit breaker

Auxiliary circuit plug connections for plug-in


bases
Accessory connections for plug-in circuit breakers (factory-wired connectors) and for plug-in
bases or withdrawable version (coupling with
screw terminal)

2)

8 terminals

3VL9 400-4PJ00

1 unit

113

0.144

Position signaling switches


(connected/disconnected position)
For plug-in/withdrawable base, 1 CO,
max. 2 signaling switches possible

3VL9 000-4WL00

1 unit

113

0.019

1)

For 3-pole applications please use 4-pole withdrawable version


with 4-pole RCD module and 4-pole circuit breaker.

2)

It is recommended to use a maximum of 3 auxiliary circuit plug-in systems


per circuit breaker (24 terminals).

3)

With VL800 (3VL6) to VL1600 (3VL8) as vertical connection.

* You can order this quantity or a multiple thereof.

2/72

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL630 (3VL5)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL800 (3VL6)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

A
A

3VL9 500-4PA30
-3VL9 500-4PA40
--

1 unit

113

8.200

1 unit

113

11.200

--A

1 unit

113

7.400

1 unit

113

9.600

3VL9 500-4WF30
-3VL9 500-4WF40
--

1 unit

113

3.600

1 unit

113

3.800

3VL9 500-4WA30
-3VL9 500-4WA40
--

1 unit

113

11.000 A

1 unit

113

15.000 A

3VL9 500-4WC30
-3VL9 500-4WC40
--

1 unit

113

10.300 A

1 unit

113

13.400 A

A
A

3VL9 500-4PS30
3VL9 500-4PS40

1
1

1 unit
1 unit

113
113

3VL9 500-4PF00

1 unit

A
A

A
A

A
A

kg

-------

3VL9 500-4PC30

3VL9 500-4PC40
--

Weight
per PU
approx.

-----

-----

3VL9 600-4WA30
-3VL9 600-4WA40
--

1 unit

113

40.104

1 unit

113

48.060

3VL9 600-4WC30
-3VL9 600-4WC40
--

1 unit

113

40.716

1 unit

113

48.876

1.260 A
1.680 A

3VL9 600-4PS30
3VL9 600-4PS40

1
1

1 unit
1 unit

113
113

1.500
2.000

113

0.018 A

3VL9 600-4PF00

1 unit

113

0.025

2)

2)

3VL9 600-4PJ00

1 unit

113

0.144 A

3VL9 600-4PJ00

1 unit

113

0.144

3VL9 000-4WL00

1 unit

113

0.019 A

3VL9 000-4WL00

1 unit

113

0.019

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/73

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL1250 (3VL7)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Plug-in versions/withdrawable versions


3- or 4-pole
Plug-in base assembly kits
Base, blade contacts for circuit breakers, terminal covers for degree of protection IP20, fixing
screws, trip pin
NSE0_00717

Rear terminals

3VL9 .00-4PA30

3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

-----

90 angle connecting adapters


For rear connection, 3-pole
For rear connection, 4-pole

---

Front-accessible terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

NSE00581

-----

3VL9 .00-4PE30
Withdrawable version assembly kits
Upgrade of the plug-in base assembly kit to
Withdrawable version
including side panels
and racking mechanism.

3-pole
3-pole with RCD
4-pole
4-pole with RCD

-----

Withdrawable version
Same as plug-in base assembly kit, with additional side panels and racking mechanism

NSE0_00719

3VL9 .00-4WF30

NSE0_00683

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 .00-4WA30

Rear terminals1)
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

3VL9 800-4WA30
-3VL9 800-4WA40
--

1 unit

113

39.996

1 unit

113

47.148

3VL9 800-4WC30
-3VL9 800-4WC40
--

1 unit

113

40.608

1 unit

113

47.964

A
A

3VL9 800-4PS30
3VL9 800-4PS40

1
1

1 unit
1 unit

113
113

2.000
2.660

3VL9 800-4PF00

1 unit

113

0.030

Front-accessible terminals
3-pole
3-pole with RCD module
4-pole
4-pole with RCD module

A
A

Blade contacts
As replacement for converting fixed-mounted
circuit breakers into plug-in/withdrawable circuit
breakers, including trip pin
1 set = 6 units
1 set = 8 units

3-pole
4-pole

Trip pins and springs


As replacement for plug-in/withdrawable
circuit breaker
Auxiliary circuit plug connections for plug-in
bases
Accessory connections for plug-in circuit breakers (factory-wired connectors) and for plug-in
bases or withdrawable version (coupling with
screw terminal)

2)

8 terminals

3VL9 800-4PJ00

1 unit

113

0.144

Position signaling switches


(connected/disconnected position)
For plug-in/withdrawable base, 1 CO,
max. 2 signaling switches possible

3VL9 000-4WL00

1 unit

113

0.019

1)

With VL800 (3VL6) to VL1600 (3VL8) as vertical connection.

2)

It is recommended to use a maximum of 3 auxiliary circuit plug-in systems


per circuit breaker (24 terminals).

* You can order this quantity or a multiple thereof.

2/74

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL1600 (3VL8)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

-----------

-----

3VL9 800-4WA30
-3VL9 800-4WA40
--

1 unit

113

39.996

1 unit

113

47.148

3VL9 800-4WC30
-3VL9 800-4WC40
--

1 unit

113

40.608

1 unit

113

47.964

A
A

3VL9 800-4PS30
3VL9 800-4PS40

1
1

1 unit
1 unit

113
113

2.000
2.660

3VL9 800-4PF00

1 unit

113

0.030

A
A

2)

3VL9 800-4PJ00

1 unit

113

0.144

3VL9 000-4WL00

1 unit

113

0.019

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/75

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Circuit breakers Rated
for system pro- current
tection, only for In
TM, starters,
disconnectors

Residual Delay time td


currents I adjustable
adjustable

Rated
operational
voltage Ue

V AC

0.03

Instantaneous

160

0.10

0.06

0.30

0.10

0.50

0.25

1.00

0.50

3.00

1.00

DT Order No.

Price
per PU

PU
PS*/
(UNIT, P. unit
SET, M)

PG

Weight
per PU
approx.

kg

RCD modules
3-pole
VL160X (3VL1)
NSE0_00582

Bottom
mounting1)3)
Mounting kit for
left side,
without
RCD1)2)3)

SENTRON VL160X
with RCD module
VL160 (3VL2)
mounted laterally on
the circuit breaker
(on left side)
VL250 (3VL3)
VL400 (3VL4)

160
250
400

127 ... 480

3VL9 112-5GA30

1 unit

113

1.340

3VL9 112-5GB30

1 unit

113

1.525

127 ... 480

3VL9 216-5GC30

1 unit

113

1.320

230 ... 690

3VL9 216-5GD30

1 unit

113

1.320

127 ... 480

3VL9 325-5GE30

1 unit

113

1.400

230 ... 690

3VL9 325-5GF30

1 unit

113

1.400

127 ... 480

--

230 ... 690

--

4-pole
VL160X (3VL1)
Bottom
mounting1)3)

160

Mounting kit for


left side,
without
RCD1)2)3)
NSE0_00583

3VL Molded Case Circuit Breakers up to 1600 A

VL160 (3VL2)
VL250 (3VL3)

SENTRON VL160X
up to VL400 with
VL400 (3VL4)
RCD module
mounted below the
circuit breaker

0.03

Instantaneous

0.10

0.06

0.30

0.10

0.50

0.25

1.00

0.50

3.00

1.00

160
250
400

Circuit breakers Rated


for system pro- current
tection, only for In
TM, starters,
disconnectors

Residual Delay time td


currents I adjustable
adjustable

127 ... 480

3VL9 112-5GA40

1 unit

113

1.590

3VL9 112-5GB40

1 unit

113

1.824

127 ... 480

3VL9 216-5GC40

1 unit

113

1.570

230 ... 690

3VL9 216-5GD40

1 unit

113

1.570

127 ... 480

3VL9 325-5GE40

1 unit

113

1.650

230 ... 690

3VL9 325-5GF40

1 unit

113

1.650

127 ... 480

3VL9 440-5GG40

1 unit

113

2.980

230 ... 690

3VL9 440-5GH40

1 unit

113

2.980

Addi- Order No. with "-Z"


tional 3VL. . . . - . E . . . - . . . . -Z
price
and additional
order code

Additional
price

Rated
operational
voltage Ue

3-pole
circuit breakers

Order No. with "-Z"


3VL. . . . - . D . . . - . . . . -Z
and additional
order code
@@@

V AC

Code for further


versions
-Z

4-pole
circuit breakers

@@@

Code for further


versions -Z

Circuit breakers with RCD module


3 and 4-pole
VL160X (3VL1)
(Bottom
mounting)

160

VL160 (3VL2)

160

VL250 (3VL3)

VL400 (3VL4)

250

400

0.03

Instantaneous

0.10

0.06

0.30

0.10

127 ... 480

A 0 1 1)3)

A 0 1 1)3)

0.50

0.25

1.00

0.50

127 ... 480

A 0 1

A 0 1

3.00

1.00

230 ... 690

A 0 2

A 0 2

127 ... 480

A 0 1

A 0 1

230 ... 690

A 0 2

A 0 2

127 ... 480

--

A 0 1

230 ... 690

--

A 0 2

Additional price
1)

Only the right-hand accessory compartment and the N conductor (4-pole)


accessory compartment can be used for the installation of accessories,
see Technical Information at
www.siemens.com/lowvoltage/support.

2)

The assembly kit consists of the mounting plate, wiring and covers for circuit breakers and RCD module (for 75 mm standard mounting rail).
The RCD module (3VL9 112-5GA30/-5GA40) must be ordered separately.

3)

VL160X (3VL1) + RCD module cannot be combined with motorized operating mechanism, front operating mechanism, door-coupling rotary operating mechanism, locking device for toggle levers, screw terminal
connections (3VL17..-....6-....) and Bowden wire interlocking.

* You can order this quantity or a multiple thereof.

2/76

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
Version

DT For VL160X (3VL1)


Order No.

PU
PS*/
Price (UNIT, P. unit
per PU SET, M)

PG

Weight
per PU
approx.
kg

Connection methods for fixed-mounted circuit breakers


3- or 4-pole
Front connecting bars1)
Phase barriers included.
Standard

NSE0_00702

3VL9 .00-4EC40

1 set = 3 units

3-pole

3VL9 216-4EC30

1 unit

113

0.198

1 set = 4 units

4-pole

3VL9 216-4EC40

1 unit

113

0.198

1 set = 3 units

3-pole

3VL9 216-4ED30

1 unit

113

0.189

1 set = 4 units

4-pole

3VL9 216-4ED40

1 unit

113

0.252

Short terminal (1 unit)

3VL9 100-4RA00

1 unit

113

0.126

Long terminal (1 unit)

3VL9 100-4RB00

1 unit

113

0.229

Terminal kit (2 short + 1 long)


3-pole

3VL9 100-4RC30

1 unit

113

0.481

Terminal kit (2 short + 2 long)


4-pole

3VL9 100-4RF40

1 unit

113

0.711

Short flat connector (1 unit)

3VL9 100-4RK00

1 unit

113

0.104

Long flat connector (1 unit)

3VL9 100-4RL00

1 unit

113

0.200

Flat connector kit


(2 short + 1 long)
3-pole

3VL9 100-4RM30

1 unit

113

0.408

Flat connector kit


(2 short + 2 long)
4-pole

3VL9 100-4RN40

1 unit

113

0.608

1 set = 3 units

3VL9 100-4TC30

1 unit

113

0.084

1 set = 4 units

3VL9 100-4TC40

1 unit

113

0.112

1 set = 3 units

3VL9 100-4TD30

1 unit

113

0.041

1 set = 4 units

3VL9 100-4TD40

1 unit

113

0.055

For increased pole spacing


NSE0_00722

3VL9 .00-4ED40
Rear terminals

NSE0_00723

3VL9 .00-4RA00,
3VL9 .00-4RB00

NSE0_00724

3VL9 .00-4RK00,
3VL9 .00-4RL00

Box terminals
For connection for flexible flat copper busbar or cable,
see Technical Information at
www.siemens.com/lowvoltage/support.
NSE0_00700

3VL9 .00-4TC.0
N S E 0 _ 0 1 5 2 9

3VL9 .00-4TD.0

Circular conductor terminals


Only for cables (Al or Cu)
Aluminum terminal (tinned)

Circular conductor terminal with terminal


covers for cable (Al or Cu)
1 set = 3 units

NSE0_00701

3VL9 .00-4TA.0

3VL9 115-4TD30

1 unit

113

0.150

1 set = 4 units

3VL9 115-4TD40

1 unit

113

0.150

Auxiliary conductor terminals


For box terminals/circular conductor terminals
1 set = 10 units

3VL9 200-3TN00

1 unit

113

0.130

1 set = 3 units

3VL9 116-4TA30

1 unit

113

0.055

1 set = 4 units

3VL9 116-4TA40

1 unit

113

0.070

Terminals with screw connection metric thread


With insulator (for rear) for use with busbars and cable
lugs, see Technical Information at
www.siemens.com/lowvoltage/support.

Connection covers
(terminal covers) for circuit breakers
Degree of protection IP30 for main connections
1 set = 2 units
NSE0_00730

3VL9 .00-3CB.0

Extended

3-pole

3VL9 300-8CA30

1 unit

113

0.204

Standard

3-pole

3VL9 300-8CB30

1 unit

113

0.053

Extended

4-pole

3VL9 300-8CA40

1 unit

113

0.264

Standard

4-pole

3VL9 300-8CB40

1 unit

113

0.071

3VL9 300-8CE00

1 unit

113

0.023

Phase barriers for circuit breakers, fixed-mounted,


plug-in or withdrawable versions
NSE0_00731

1 set = 2 units

3VL9 .00-8CE00
1)

Screw terminal connections are required for SENTRON VL160X and VL160 (3VL1 and 3VL2) circuit breakers,
see Technical Information at www.siemens.com/lowvoltage/support.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/77

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Accessories and spare parts
Version

DT

For VL160 (3VL2)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Connection components for fixed-mounted circuit breakers


3- or 4-pole
Front connecting bars1)
Phase barriers included.
NSE0_00702

3VL9 .00-4EC40

Standard
1 set = 3 units
1 set = 4 units

3-pole
4-pole

A
A

3VL9 216-4EC30
3VL9 216-4EC40

1
1

1 unit
1 unit

113
113

0.198
0.198

A
A

3VL9 216-4ED30
3VL9 216-4ED40

1
1

1 unit
1 unit

113
113

0.189
0.252

Short terminal (1 unit)


Long terminal (1 unit)

A
A

3VL9 200-4RA00
3VL9 200-4RB00

1
1

1 unit
1 unit

113
113

0.126
0.229

Terminal kit (2 short + 1 long) 3-pole


Terminal kit (2 short + 2 long) 4-pole

A
A

3VL9 200-4RC30
3VL9 200-4RF40

1
1

1 unit
1 unit

113
113

0.481
0.711

Short flat connector (1 unit)


Long flat connector (1 unit)

A
A

3VL9 200-4RK00
3VL9 200-4RL00

1
1

1 unit
1 unit

113
113

0.104
0.200

Flat connector kit (2 short + 1 long) 3-pole


Flat connector kit (2 short + 2 long) 4-pole

A
A

3VL9 200-4RM30
3VL9 200-4RN40

1
1

1 unit
1 unit

113
113

0.408
0.608

A
A

3VL9 200-4TC30
3VL9 200-4TC40

1
1

1 unit
1 unit

113
113

0.084
0.112

C
C

3VL9 200-4TD30
3VL9 200-4TD40

1
1

1 unit
1 unit

113
113

0.041
0.055

A
B

3VL9 215-4TD30
3VL9 215-4TD40

1
1

1 unit
1 unit

113
113

0.150
0.150

For increased pole spacing


NSE0_00722

3VL9 .00-4ED40

1 set = 3 units
1 set = 4 units

3-pole
4-pole

Rear terminals

NSE0_00723

3VL9 .00-4RA00,
3VL9 .00-4RB00

NSE0_00724

3VL9 .00-4RK00,
3VL9 .00-4RL00

Box terminals
Connection for flexible flat copper busbar or
cable,
see Technical Information at
www.siemens.com/lowvoltage/support.
1 set = 3 units
1 set = 4 units

NSE0_00700

3VL9 .00-4TC.0
N S E 0 _ 0 1 5 2 9

Circular conductor terminals


Only for cables (Al or Cu)
Aluminum terminal (tinned)
1 set = 3 units
1 set = 4 units

3VL9 .00-4TD.0

Circular conductor terminal with terminal


covers for cable (Al or Cu)
1 set = 3 units
1 set = 4 units

Multiple feed-in terminals


N S E 0 _ 0 1 5 4 2

N S E 0 _ 0 1 5 4 3

3VL9 .00-4TF.0

3 units
4 units
Multiple feed-in terminal
with terminal covers
3 units (2 70 ... 300)
4 units (2 70 ... 300)

Auxiliary conductor terminals


For box terminals/circular conductor terminals/multiple feed-in terminals
1 set = 10 units

NSE0_00701

3VL9 .00-4TA.0

--A

3VL9 200-3TN00

1 unit

113

0.130

A
A

3VL9 216-4TA30
3VL9 216-4TA40

1
1

1 unit
1 unit

113
113

0.055
0.070

A
A
A
A

3VL9 300-8CA30
3VL9 300-8CB30
3VL9 300-8CA40
3VL9 300-8CB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.204
0.053
0.264
0.071

3VL9 300-8CE00

1 unit

113

0.023

Terminals with screw connection metric thread


With insulator (for rear) for use with busbars and
cable lugs, see Technical Information at
www.siemens.com/lowvoltage/support.
1 set = 3 units
1 set = 4 units
Connection covers
(terminal covers) for circuit breakers
Degree of protection IP30 for main connections
1 set = 2 units

NSE0_00730

3VL9 .00-3CB.0

Extended
Standard
Extended
Standard

3-pole
3-pole
4-pole
4-pole

Phase barriers for circuit breakers, fixed-mounted,


plug-in or withdrawable versions

NSE0_00731

3VL9 .00-8CE00
1)

---

1 set = 2 units

Screw terminal connections are required for SENTRON VL160X and VL160 (3VL1 and 3VL2) circuit breakers,
see Technical Information at www.siemens.com/lowvoltage/support.

* You can order this quantity or a multiple thereof.

2/78

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL250 (3VL3)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL400 (3VL4)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

A
A

3VL9 300-4EC30
3VL9 300-4EC40

1
1

1 unit
1 unit

113
113

0.256 A
0.345 A

3VL9 400-4EC30
3VL9 400-4EC40

1
1

1 unit
1 unit

113
113

0.889
1.193

A
A

3VL9 300-4ED30
3VL9 300-4ED40

1
1

1 unit
1 unit

113
113

0.256 A
0.345 A

3VL9 400-4ED30
3VL9 400-4ED40

1
1

1 unit
1 unit

113
113

0.916
1.229

A
A

3VL9 300-4RA00
3VL9 300-4RB00

1
1

1 unit
1 unit

113
113

0.126 A
0.229 A

3VL9 400-4RA00
3VL9 400-4RB00

1
1

1 unit
1 unit

113
113

0.219
0.377

A
A

3VL9 300-4RC30
3VL9 300-4RF40

1
1

1 unit
1 unit

113
113

0.481 A
0.711 A

3VL9 400-4RC30
3VL9 400-4RF40

1
1

1 unit
1 unit

113
113

0.816
1.192

A
A

3VL9 300-4RK00
3VL9 300-4RL00

1
1

1 unit
1 unit

113
113

0.104 A
0.200 A

3VL9 400-4RK00
3VL9 400-4RL00

1
1

1 unit
1 unit

113
113

0.343
0.502

A
A

3VL9 300-4RM30
3VL9 300-4RN40

1
1

1 unit
1 unit

113
113

0.408 A
0.608 A

3VL9 400-4RM30
3VL9 400-4RN40

1
1

1 unit
1 unit

113
113

1.190
1.690

A
A

3VL9 300-4TC30
3VL9 300-4TC40

1
1

1 unit
1 unit

113
113

0.192 A
0.256 A

3VL9 400-4TC30
3VL9 400-4TC40

1
1

1 unit
1 unit

113
113

0.423
0.573

C
C

3VL9 300-4TD30
3VL9 300-4TD40

1
1

1 unit
1 unit

113
113

0.159 C
0.212 C

3VL9 400-4TD30
3VL9 400-4TD40

1
1

1 unit
1 unit

113
113

0.260
0.340

B
B

3VL9 324-4TD30
3VL9 324-4TD40

1
1

1 unit
1 unit

113
113

0.150
0.150

---

---

C
C

3VL9 400-4TF30
3VL9 400-4TF40

1
1

1 unit
1 unit

113
113

0.420
0.560

---

B
B

3VL9 460-4TF30
3VL9 460-4TF40

1
1

1 unit
1 unit

113
113

0.150
0.150

3VL9 300-3TN00

1 unit

113

0.150 A

3VL9 400-3TN00

1 unit

113

0.140

A
A

3VL9 300-4TA30
3VL9 300-4TA40

1
1

1 unit
1 unit

113
113

0.090 A
0.120 A

3VL9 400-4TA30
3VL9 400-4TA40

1
1

1 unit
1 unit

113
113

0.112
0.149

A
A
A
A

3VL9 300-8CA30
3VL9 300-8CB30
3VL9 300-8CA40
3VL9 300-8CB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.204
0.053
0.264
0.071

A
A
A
A

3VL9 400-8CA30
3VL9 400-8CB30
3VL9 400-8CA40
3VL9 400-8CB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.450
0.120
0.594
0.164

3VL9 300-8CE00

1 unit

113

0.023 A

3VL9 600-8CE00

1 unit

113

0.042

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/79

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL630 (3VL5)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Connection components for fixed-mounted circuit breakers


3- or 4-pole
Front connecting bars
Phase barriers included.
NSE0_00702

3VL9 .00-4EC40

Standard
1 set = 3 units
1 set = 4 units

3-pole
4-pole

A
A

3VL9 500-4EC30
3VL9 500-4EC40

1
1

1 unit
1 unit

113
113

1.028
1.371

A
A

3VL9 500-4ED30
3VL9 500-4ED40

1
1

1 unit
1 unit

113
113

1.059
1.412

For increased pole spacing


NSE0_00722

3VL9 .00-4ED40

1 set = 3 units
1 set = 4 units

3-pole
4-pole

Rear terminals

NSE0_00723

3VL9 .00-4RA00,
3VL9 .00-4RB00

NSE0_00724

3VL9 .00-4RK00,
3VL9 .00-4RL00
NSE0_00725

3VL Molded Case Circuit Breakers up to 1600 A

---

Terminal kit (2 short + 1 long) 3-pole


Terminal kit (2 short + 2 long) 4-pole

---

Short flat connector (1 unit)


Long flat connector (1 unit)

---

Flat connector kit (2 short + 1 long) 3-pole


Flat connector kit (2 short + 2 long) 4-pole

---

Flat connecting bar (1 unit)


Flat connecting bar
Set = 3 units, 3-pole
Flat connecting bar
Set = 4 units, 4-pole

3VL9 500-4RG00

1 unit

113

0.358

3VL9 500-4RH30

1 unit

113

1.075

3VL9 500-4RH40

1 unit

113

1.433

1 set = 3 units
1 set = 4 units

C
C

3VL9 500-4TG30
3VL9 500-4TG40

1
1

1 unit
1 unit

113
113

0.461
0.614

Auxiliary conductor terminals


For multiple feed-in terminals
1 set = 10 units

3VL9 400-3TN00

1 unit

113

0.140

A
A

3VL9 500-4TT30
3VL9 500-4TT40

1
1

1 unit
1 unit

113
113

1.350
1.800

C
C

3VL9 500-4TA30
3VL9 500-4TA40

1
1

1 unit
1 unit

113
113

0.150
0.200

A
A
A
A

3VL9 600-8CA30
3VL9 600-8CB30
3VL9 600-8CA40
3VL9 600-8CB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.696
0.210
0.960
0.270

3VL9 600-8CE00

1 unit

113

0.042

Multiple feed-in terminals


Only for cables (Al or Cu)
Aluminum terminal (tinned)

3VL9 .00-4RG00

N S E 0 _ 0 1 5 4 2

Short terminal (1 unit)


Long terminal (1 unit)

N S E 0 _ 0 1 5 4 3

3VL9 .00-4TF.0

Terminal plates1)
Connection for flexible flat copper busbar with
auxiliary conductor connection 0.5 4 mm2
(extended terminal covers or phase barriers
required)
1 set = 3 units
1 set = 4 units

N S E 0 _ 0 1 5 4 4

3VL9 .00-4TG.0

Terminals with screw connection metric thread


With insulator (for rear) for use with busbars and
cable lugs, see Technical Information at
www.siemens.com/lowvoltage/support.
1 set = 3 units
1 set = 4 units

N S E 0 _ 0 1 5 3 0

3VL9 .00-4TT.0

NSE0_00701

3VL9 .00-4TA.0

Connection covers
(terminal covers) for circuit breakers
Degree of protection IP30 for main connections
1 set = 2 units
Extended
Standard
Extended
Standard

3-pole
3-pole
4-pole
4-pole

Phase barriers for circuit breakers, fixed-mounted,


plug-in or withdrawable versions2)
NSE0_00730

1 set = 2 units

3VL9 .00-3CB.0

NSE0_00731

3VL9 .00-8CE00
1)

Front connecting bars included in scope of supply; not for 690 V AC/600 V DC.

* You can order this quantity or a multiple thereof.

2/80

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL800 (3VL6)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL1250 (3VL7)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

A
A

3VL9 600-4EC30
3VL9 600-4EC40

1
1

1 unit
1 unit

113
113

1.602 C
2.136 C

3VL9 800-4EC30
3VL9 800-4EC40

A
A

3VL9 600-4ED30
3VL9 600-4ED40

1
1

1 unit
1 unit

113
113

1.613
2.154

---

---

---

---

---

---

---

---

---

1
1

1 unit
1 unit

113
113

3.313
4.438

3VL9 600-4RG00

1 unit

113

1.604 A

3VL9 700-4RG00

1 unit

113

1.604

3VL9 600-4RH30

1 unit

113

4.812 A

3VL9 700-4RH30

1 unit

113

4.812

3VL9 600-4RH40

1 unit

113

6.416 A

3VL9 700-4RH40

1 unit

113

6.416

C
C

3VL9 600-4TG30
3VL9 600-4TG40

1
1

1 unit
1 unit

113
113

0.918 C
1.224 C

3VL9 700-4TG30
3VL9 700-4TG40

1
1

1 unit
1 unit

113
113

2.175
2.900

3VL9 400-3TN00

1 unit

113

0.140 A

3VL9 400-3TN00

1 unit

113

0.140

---

---

C
C

3VL9 600-4TA30
3VL9 600-4TA40

1
1

1 unit
1 unit

113
113

0.289 C
0.386 C

3VL9 800-4TA30
3VL9 800-4TA40

1
1

1 unit
1 unit

113
113

0.319
0.426

A
A
A
A

3VL9 600-8CA30
3VL9 600-8CB30
3VL9 600-8CA40
3VL9 600-8CB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

0.696
0.210
0.960
0.270

A
A
A
A

3VL9 800-8CA30
3VL9 800-8CB30
3VL9 800-8CA40
3VL9 800-8CB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

113
113
113
113

1.060
0.360
1.326
0.470

3VL9 600-8CE00

1 unit

113

0.042 C

3VL9 800-8CE00

1 unit

113

0.130

2)

Plug-in version: Not for VL1250 (3VL7),


withdrawable version: Not for VL800 (3VL6) and VL1250 (3VL7).

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/81

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL1600 (3VL8)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Connection components for fixed-mounted circuit breakers


3- or 4-pole
Front connecting bars
Phase barriers included.
Standard
NSE0_00702

3VL9 .00-4EC40

1 set = 3 units

3-pole

3VL9 800-4EC30

1 unit

113

3.313 1)

1 set = 4 units

4-pole

3VL9 800-4EC40

1 unit

113

4.438 1)

For increased pole spacing


NSE0_00722

3VL9 .00-4ED40

1 set = 3 units

3-pole

--

1 set = 4 units

4-pole

--

Rear terminals

NSE0_00723

3VL9 .00-4RA00,
3VL9 .00-4RB00

NSE0_00724

3VL9 .00-4RK00,
3VL9 .00-4RL00
NSE0_00725

3VL Molded Case Circuit Breakers up to 1600 A

Short terminal (1 unit)

--

Long terminal (1 unit)

--

Terminal kit (2 short + 1 long)


3-pole

--

Terminal kit (2 short + 2 long)


4-pole

--

Short flat connector (1 unit)

--

Long flat connector (1 unit)

--

Flat connector kit (2 short + 1 long)


3-pole

--

Flat connector kit (2 short + 2 long)


4-pole
Flat connecting bar (1 unit)

3VL9 .00-4RG00

Flat connecting bar


Set = 3 units, 3-pole
Flat connecting bar
Set = 4 units, 4-pole

-A

3VL9 800-4RG00

1 unit

113

1.527

3VL9 800-4RH30

1 unit

113

4.581

3VL9 800-4RH40

1 unit

113

6.108

Box terminals
For connection for flexible flat copper busbar or
cable, see Technical Information at
www.siemens.com/lowvoltage/support.

NSE0_00700

3VL9 .00-4TC.0

N S E 0 _ 0 1 5 4 4

3VL9 .00-4TG.0

NSE0_00701

3VL9 .00-4TA.0

1 set = 3 units

--

1 set = 4 units

--

Multiple feed-in terminals


Only for cables (Al or Cu)
Aluminum terminal (tinned)
1 set = 3 units

--

1 set = 4 units

--

Auxiliary conductor terminals


For box terminals/aluminum terminals

--

Terminals with screw connection metric thread


With insulator (for rear) for use with busbars and
cable lugs, see Technical Information at
www.siemens.com/lowvoltage/support.
1 set = 3 units

3VL9 800-4TA30

1 unit

113

0.319

1 set = 4 units

3VL9 800-4TA40

1 unit

113

0.426

Connection covers
(terminal covers) for circuit breakers
Degree of protection IP30 for main connections
1 set = 2 units

NSE0_00730

3VL9 .00-3CB.0

NSE0_00731

3VL9 .00-8CE00

Extended

3-pole

3VL9 800-8CA30

1 unit

113

1.060

Standard

3-pole

3VL9 800-8CB30

1 unit

113

0.360

Extended

4-pole

3VL9 800-8CA40

1 unit

113

1.326

Standard

4-pole

3VL9 800-8CB40

1 unit

113

0.470

3VL9 800-8CE00

1 unit

113

0.130

Phase barriers for fixed-mounted circuit


breakers
1 set = 2 units

1)

In scope of supply of circuit breaker.

* You can order this quantity or a multiple thereof.

2/82

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
Version

DT

For VL160X (3VL1)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Interlocks
3- or 4-pole
C

3VL9 300-3HL00

1 unit

113

0.052

Fixed-mounted circuit breakers

3VL9 300-8LC00

1 unit

113

0.215

Plug-in/withdrawable circuit breakers

3VL9 300-8LD00

1 unit

113

0.223

Locking devices for toggle levers


For locking the circuit breaker in the "OFF" position.
Up to 3 padlocks with 5 8 mm can be used.
Removable (padlocks not included)
Rear interlocking modules
For the mechanical interlocking of two adjacent
circuit breakers. The circuit breakers must be of the
same installation type and size.
(Mounting plate not included in scope of supply)

NSE0_00732

3VL9 .00-3HL00

Interlocking modules for Bowden wire


interlocking 1)
For the mechanical interlocking of two circuit
breakers.
Interlocking module for one circuit breaker

NSE0_00733

3VL9 .00-8L.00

Combination with next size up possible


(see Order No.)
C

3VL9 300-8LA00

1 unit

113

0.174

Wire length 0.5 m

3VL9 000-8LH10

1 unit

113

0.206

Wire length 1.0 m

3VL9 000-8LH20

1 unit

113

0.298

Wire length 1.5 m

3VL9 000-8LH30

1 unit

113

0.412

3VL9 715-8HA00

1 unit

113

0.309

NSE0_00734

Bowden wires for Bowden wire interlocking1)

3VL9 .00-8LA00
Safety lock assembly kits
Key can be removed with the circuit breaker in the
"OFF" position
For front-operated rotary operating mechanisms
Lock types
Ronis
For motorized operating mechanism with stored
energy mechanism

NSE0_00680

Lock types
Ronis
Filli Giussani

-A

3VL9 321-8HA00

1 unit

113

0.053

3VL9 300-8SA40

1 unit

113

0.030

1 unit

113

0.015

Sets of fixing screws


(metric thread)
Including the screws, washers and nuts required to
secure a 3- or 4-pole circuit breaker to a prepared
surface

3VL9 ...-8HA00

Set with 4 screws


Transparent covers for releases, sealable
To prevent access by unqualified personnel and
unauthorized changes to settings (seal not included)
Electronic releases
Thermal-magnetic

3VL9 300-8BM00
--

NSE0_01531a

Battery power supply for activating/


parameterizing the LCD ETU release, with test
function for all IEC and UL ETUs
(two 9 V blocks are required in addition)

-A

3VL9 000-8AP01
1)

Two interlocking modules and one Bowden wire are required. Cannot be
used in conjunction with motorized operating mechanism and withdrawable version.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/83

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL160 (3VL2)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Interlocks
3- or 4-pole
Locking devices for toggle levers
For locking the circuit breaker in the "OFF" position.
Up to 3 padlocks with 5 8 mm can be used.
Removable (padlocks not included)

3VL9 300-3HL00

1 unit

113

0.052

Fixed-mounted circuit breakers

3VL9 300-8LC00

1 unit

113

0.215

Plug-in/withdrawable circuit breakers

3VL9 300-8LD00

1 unit

113

0.223

Rear interlocking modules


For the mechanical interlocking of two adjacent
circuit breakers. The circuit breakers must be of the
same installation type and size.
(Mounting plate not included in scope of supply)

NSE0_00732

3VL9 .00-3HL00

Interlocking modules for Bowden wire


interlocking 1)
For the mechanical interlocking of two circuit
breakers.
Interlocking module for one circuit breaker

NSE0_00733

3VL9 .00-8L.00

Combinations with next size up/down possible


(see Order No.)
C

3VL9 300-8LA00

1 unit

113

0.174

Wire length 0.5 m

3VL9 000-8LH10

1 unit

113

0.206

Wire length 1.0 m

3VL9 000-8LH20

1 unit

113

0.298

Wire length 1.5 m

3VL9 000-8LH30

1 unit

113

0.412

3VL9 715-8HA00

1 unit

113

0.309

Bowden wires for Bowden wire interlocking1)

NSE0_00734

Safety lock assembly kits


Key can be removed with the circuit breaker in the
"OFF" position
For front-operated rotary operating mechanisms

3VL9 .00-8LA00

Lock types
Ronis
For motorized operating mechanism with stored
energy mechanism

NSE0_00680

Lock types
Ronis
Filli Giussani

-A

3VL9 321-8HA00

1 unit

113

0.053

3VL9 300-8SA40

1 unit

113

0.030

Electronic releases

3VL9 700-8BL00

1 unit

113

0.002

Thermal-magnetic

3VL9 300-8BM00

1 unit

113

0.015

Battery power supply for activating/


parameterizing the LCD ETU release, with test
function for all IEC and UL ETUs
(two 9 V blocks are required in addition)

3VL9 000-8AP01

1 unit

113

0.605

Sets of fixing screws


(metric thread)
Including the screws, washers and nuts required to
secure a 3- or 4-pole circuit breaker to a prepared
surface

3VL9 ...-8HA00

Set with 4 screws


Transparent covers for releases, sealable
To prevent access by unqualified personnel and
unauthorized changes to settings (seal not included)

NSE0_01531a

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 000-8AP01
1)

Two interlocking modules and one Bowden wire are required. Cannot be
used in conjunction with motorized operating mechanism and withdrawable version.

* You can order this quantity or a multiple thereof.

2/84

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL250 (3VL3)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL400 (3VL4)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

3VL9 300-3HL00

1 unit

113

0.052 C

3VL9 400-3HL00

1 unit

113

0.122

3VL9 300-8LC00

1 unit

113

0.215 C

3VL9 400-8LC00

1 unit

113

0.386

3VL9 300-8LD00

1 unit

113

0.223 C

3VL9 400-8LD00

1 unit

113

0.436

3VL9 300-8LA00

1 unit

113

0.174 C

3VL9 400-8LA00

1 unit

113

0.196

3VL9 000-8LH10

1 unit

113

0.206

--

3VL9 000-8LH20

1 unit

113

0.298 C

3VL9 000-8LH20

1 unit

113

0.298

3VL9 000-8LH30

1 unit

113

0.412 C

3VL9 000-8LH30

1 unit

113

0.412

3VL9 715-8HA00

1 unit

113

0.309 A

3VL9 715-8HA00

1 unit

113

0.309

3VL9 715-8HA00

1 unit

113

0.309

-A

3VL9 321-8HA00

1 unit

113

0.053

--

3VL9 300-8SA40

1 unit

113

0.030 C

3VL9 500-8SA40

1 unit

113

0.090

3VL9 700-8BL00

1 unit

113

0.002 C

3VL9 700-8BL00

1 unit

113

0.002

3VL9 300-8BM00

1 unit

113

0.015 A

3VL9 400-8BM00

1 unit

113

0.017

3VL9 000-8AP01

1 unit

113

0.605 B

3VL9 000-8AP01

1 unit

113

0.605

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/85

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL630 (3VL5)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Interlocks
3- or 4-pole
Locking devices for toggle levers
For locking the circuit breaker in the "OFF" position.
Up to 3 padlocks with 5 8 mm can be used.
Removable (padlocks not included)

3VL9 600-3HL00

1 unit

113

0.130

Fixed-mounted circuit breakers

3VL9 600-8LC00

1 unit

113

1.499

Plug-in/withdrawable circuit breakers

3VL9 600-8LD00

1 unit

113

5.076

1 unit

113

0.244

Rear interlocking modules


For the mechanical interlocking of two adjacent circuit breakers. The circuit breakers must be of the
same installation type and size. (Mounting plate not
included in scope of supply)

NSE0_00732

3VL9 .00-3HL00

Interlocking modules for Bowden wire


interlocking 1)
For the mechanical interlocking of two circuit
breakers.
Interlocking module for one circuit breaker

NSE0_00733

3VL9 .00-8L.00

Combinations with next size up/down possible


(see Order No.)
C

3VL9 600-8LA00

Bowden wires for Bowden wire interlocking1)


Wire length 0.5 m
NSE0_00734

--

Wire length 1.0 m

3VL9 000-8LH20

1 unit

113

0.298

Wire length 1.5 m

3VL9 000-8LH30

1 unit

113

0.412

3VL9 715-8HA00

1 unit

113

0.309

3VL9 715-8HA00

1 unit

113

0.309

Safety lock assembly kits


Key can be removed with the circuit breaker in the
"OFF" position
For front-operated rotary operating mechanisms

3VL9 .00-8LA00

Lock types
Ronis
For motorized operating mechanism with stored
energy mechanism

NSE0_00680

Lock types
Ronis
Filli Giussani

--

Sets of fixing screws


(metric thread)
Including the screws, washers and nuts required to
secure a 3- or 4-pole circuit breaker to a prepared
surface

3VL9 ...-8HA00

Set with 4 screws

3VL9 500-8SA40

1 unit

113

0.090

Electronic releases

3VL9 700-8BL00

1 unit

113

0.002

Thermal-magnetic

3VL9 600-8BM00

1 unit

113

0.019

Battery power supply for activating/


parameterizing the LCD ETU release, with test
function for all IEC and UL ETUs
(two 9 V blocks are required in addition)

3VL9 000-8AP01

1 unit

113

0.605

Transparent covers for releases, sealable


To prevent access by unqualified personnel and
unauthorized changes to settings (seal not included)

NSE0_01531a

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 000-8AP01
1)

Two interlocking modules and one Bowden wire are required.


Cannot be used in conjunction with motorized operating mechanism and
withdrawable version.

* You can order this quantity or a multiple thereof.

2/86

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL800 (3VL6)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL1250 (3VL7)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

3VL9 600-3HL00

1 unit

113

0.130 C

3VL9 800-3HL00

1 unit

113

0.238

3VL9 600-8LC00

1 unit

113

1.499 C

3VL9 800-8LC00

1 unit

113

2.935

3VL9 600-8LD00

1 unit

113

5.076 C

3VL9 800-8LD00

1 unit

113

3.825

3VL9 600-8LA00

1 unit

113

0.244 C

3VL9 800-8LA00

1 unit

113

0.283

--

--

3VL9 000-8LH20

1 unit

113

0.298

--

3VL9 000-8LH30

1 unit

113

0.412 C

3VL9 000-8LH30

1 unit

113

0.412

3VL9 715-8HA00

1 unit

113

0.309 A

3VL9 715-8HA00

1 unit

113

0.309

3VL9 715-8HA00

1 unit

113

0.309 A

3VL9 715-8HA00

1 unit

113

0.309

--

--

3VL9 600-8SA40

1 unit

113

0.090 A

3VL9 800-8SA40

1 unit

113

0.090

3VL9 700-8BL00

1 unit

113

0.002 C

3VL9 700-8BL00

1 unit

113

0.002

1 unit

113

0.605

--

3VL9 000-8AP01

--

1 unit

113

0.605 B

3VL9 000-8AP01

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/87

Siemens AG 2011

Molded Case Circuit Breakers


Accessories and spare parts
Version

DT

For VL1600 (3VL8)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Interlocks
3- or 4-pole
Locking devices for toggle levers
For locking the circuit breaker in the "OFF" position.
Up to 3 padlocks with 5 8 mm can be used.
Removable (padlocks not included)

3VL9 800-3HL00

1 unit

113

0.238

Circuit breakers, fixed-mounted1)

3VL9 800-8LC00

1 unit

113

2.935

Plug-in/withdrawable circuit breakers

3VL9 800-8LD00

1 unit

113

3.825

Interlocking modules for Bowden wire


interlocking 2)
For the mechanical interlocking of two circuit break- C
ers.
Interlocking module for one circuit breaker

3VL9 800-8LA00

1 unit

113

0.283

Rear interlocking modules


For the mechanical interlocking of two adjacent circuit breakers. The circuit breakers must be of the
same installation type and size.

NSE0_00732

3VL9 .00-3HL00

NSE0_00733

3VL9 .00-8L.00

Bowden wires for Bowden wire interlocking2)


Wire length 0.5 m

--

Wire length 1.0 m


NSE0_00734

Wire length 1.5 m

-C

3VL9 000-8LH30

1 unit

113

0.412

3VL9 715-8HA00

1 unit

113

0.309

3VL9 715-8HA00

1 unit

113

0.309

Safety lock assembly kits


Key can be removed with the circuit breaker in the
"OFF" position
For front-operated rotary operating mechanisms

3VL9 .00-8LA00

Lock types
Ronis
For motorized operating mechanisms

NSE0_00680

Lock types
Ronis
Filli Giussani

--

Sets of fixing screws


(metric thread)
Including the screws, washers and nuts required to
secure a 3- or 4-pole circuit breaker to a prepared
surface

3VL9 ...-8HA00

Set with 4 screws

3VL9 800-8SA40

1 unit

113

0.090

3VL9 700-8BL00

1 unit

113

0.002

1 unit

113

0.605

Transparent covers for releases, sealable


To prevent access by unqualified personnel and
unauthorized changes to settings (seal not included)
Electronic releases
Thermal-magnetic
Battery power supply for activating/
parameterizing the LCD ETU release, with test
function for all IEC and UL ETUs
(two 9 V blocks are required in addition)

--

3VL9 000-8AP01

NSE0_01531a

3VL Molded Case Circuit Breakers up to 1600 A

3VL9 000-8AP01
1)

Mounting plate not included in scope of supply.

2)

Two interlocking modules and one Bowden wire are required.


Cannot be used in conjunction with motorized operating mechanism and
withdrawable version.

* You can order this quantity or a multiple thereof.

2/88

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts

Busbar adapter systems with 40 mm or 60 mm busbar center-to-center spacing with components for busbar runs, adapters and switching device holders for
individual equipment possibilities, devices with an integrated adapter, as well as accessories and flat copper profiles. Observe the short-circuit strength of the
busbar system. Short-circuit strength greater than 50 kA on request.

See also "Busbar Systems" chapter.


Version

DT Order No.

Price
per PU

PU
PS*/
(UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

40 mm busbar adapter systems


According to DIN 43870 Part 2 for copper busbars
with sharp (DIN 1759) and with rounded (DIN 46433) edges,
width 12 mm and 15 mm, thickness 5 mm and 10 mm.
Up to 160 A
Busbar adapters, length 175 mm
With plug connection tags at top, 3-pole
With terminal cover (degree of protection IP10)1)
For one VL160X (3VL1) circuit breaker2)
108 mm wide
1)

For degree of protection IP30, the terminal covers from page 2/77 to 2/82
should be ordered.

2)

Usable only for 3VL circuit breakers with line-side box terminals.

8US10 11-4SL01

1 unit

143

0.585

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/89

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Accessories and spare parts
Version

DT Order No.

Price
per PU

PU
PS*/
(UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

60 mm busbar adapter systems


For copper busbars with sharp (DIN 1759) and with rounded (DIN 46433) edges,
width 12 mm to 30 mm, thickness 5 mm and 10 mm, also for T and double-T special profiles
Up to 160 A
Busbar adapters, length 175 mm
With plug connection tags at top, 3-pole
With terminal cover (degree of protection IP10)1)
For one VL160X/VL160 (3VL1, 3VL2) 108 mm wide A
circuit breaker2)

8US12 11-4SL01

1 unit

143

0.597

8US12 11-4SL00

1 unit

143

0.662

8US12 10-4AF00

1 unit

143

2.769

Up to 250 A
Busbar adapters, length 175 mm
With plug connection tags at top, 3-pole
With terminal cover (degree of protection IP10)1)
For one VL250 (3VL3) circuit breaker 108 mm wide A

8US12 114SL01

Up to 400 A
Busbar adapters, length 320 mm
With threaded inserts M4, M6 and M8
For various types of switching devices, 3-pole
Without connecting cables,
with M10 terminal screws at top and bottom1)
Adapter
185 mm wide A
Mounting plates for 8US12 104AF00

8US12 104AF00
1)

For VL400 (3VL4) circuit breakers


(also for VL160X+RCD, VL160, VL250 circuit
breakers (3VL1 + RCD, 3VL2, 3VL3))

8US19 27-4AF01

1 unit

143

0.575

For VL630 (3VL5) circuit breakers


(In max = 580 V)

8US12 13-4AF00

1 unit

143

2.880

The connecting cable between adapter and switching device should be manufactured in accordance
with the rated current as a round cable,
e.g. H07V-R, with a cable lug or as a flat conductor
for bolt-type connection M10 (adapter).

For degree of protection IP30, the terminal covers from page 2/77 to 2/82
should be ordered.
Type

Rated current In

2)

Usable only for 3VL circuit breakers with line-side box terminals.

DT Order No.

Price
per PU

PU
PS*/
(UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Further accessories
Current transformers (-T6) for N conductor/grounded neutral point of the transformer
for ground-fault protection in 4-wire three-phase systems1)
VL160/3VL2

3VL9 280-8TC00

1 unit

113

0.500

100

3VL9 210-8TC00

1 unit

113

0.450

160

3VL9 216-8TC00

1 unit

113

0.485

200

3VL9 320-8TC00

1 unit

113

0.445

250

3VL9 325-8TC00

1 unit

113

0.493

315

3VL9 440-8TC00

1 unit

113

0.493

400

3VL9 440-8TC00

1 unit

113

0.493

VL630/3VL5

630

3VL9 563-8TC00

1 unit

113

0.760

VL800/3VL6

800

3VL9 680-8TC00

1 unit

113

0.778

VL1250/3VL7 1000

3VL9 712-8TC00

1 unit

113

2.080

1250

3VL9 712-8TC00

1 unit

113

2.080

VL1600/3VL8 1600

3VL9 816-8TC00

1 unit

113

2.110

VL250/3VL3
VL400/3VL4

NSE-00572

1)

63, 80

Please note the rated current of the circuit breaker.

* You can order this quantity or a multiple thereof.

2/90

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
General criteria for the selection of current transformers for measurement purposes

4NC53 current transformers


Standards
Window-type current transformers

Rated primary current Ipn


Rated secondary current Isn
1A
5A

Accuracy class
Class 1
Class 3
Rated power Pn

Maximum voltage for equipment Um

Overcurrent limiting factor FS

Rated short-time thermal current Ith


Rated impulse current Idyn

EN 60044-1
The conductor to be measured (busbar or cable) is passed through the window opening and constitutes the
primary circuit of the window-type current transformer.
Pin-wound transformers: An economical solution especially for small primary currents of 5 ... 75 A is achieved
when the conductor to be measured is pin-wound several times.
Current transformers can be continuously loaded with 1.3 times the rated primary current (Ipn).
Particularly suitable for longer measuring leads. Cable losses of only 4 % in contrast to 5 A current transformers.
5 A current transformers generate 25 times the power losses on measuring leads as compared with 1 A current
transformers. These stray losses result in higher power in the case of long cables. Only recommended for use
with short measuring leads.
Operation measurement, internal metering
Current error 1 % at 1 x Ipn and 1.2 x Ipn
Coarse measurement
Current error 3 % at 0.5 x Ipn and 1.2 x Ipn
The rated power of transformers is specified in VA. The actual load rating should be similar to the rated power;
a lower actual load rating (underburden) increases the overcurrent factor and measuring devices may be damaged in case of a short-circuit, a higher actual load rating (overburden) has a negative effect on the accuracy.
With a frequency of 60 Hz the rated power increases to 1.2 times. With 162/3Hz the output power decreases to
1
/3 of the rated power.
This is the rms value of the maximum voltage between the conductors of a system. For this voltage the insulation must be rated at normal operating conditions.
4NC5 current transformers are suitable for 720 V.
The overcurrent limiting factor is expressed using the characters FS and a factor, e.g. FS5 or FS10.
When a short-circuit current flows through the primary winding of a current transformer, the load on the measuring devices connected to the current transformer is the lower the smaller the overcurrent limiting factor is.
The rated short-time thermal current Ith is the rms value of the primary current with a duration of one second,
whose heat effect the current transformer can resist without being damaged in the event of a short-circuited
secondary winding.
The rated impulse current Idyn is the highest instantaneous value of the current after a short-circuit whose force
the current transformer can resist without being damaged.
The rated impulse current is specified as peak value.

Siemens LV 10.1 2011

2/91

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Accessories and spare parts
4NC current transformers for measuring purposes
Rated primary current Ipn

Rating Pn

VA

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Classes 1 and 3, from 50 to 1500 A


Rated secondary current 1A
Class 3
For circular conductors with max. diameter 17.5 mm
For busbars up to max. 12 mm 10 mm
50
60
75

2.5
2.5
2.5

A
A
A

4NC51 12-0BC20
4NC51 13-0BC20
4NC51 15-0BC20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.428
0.432
0.425

A
A
A
A

4NC51 17-0CC20
4NC51 21-0CC20
4NC51 22-0CE20
4NC51 23-0CE20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.335
0.327
0.356
0.352

A
A
A
A

4NC52 22-0CE20
4NC52 23-0CE20
4NC52 24-0CE20
4NC52 25-0CE20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.464
0.477
0.363
0.373

A
A
A
A

4NC53 25-0CE20
4NC53 26-0CE20
4NC53 27-0CE20
4NC53 28-0CE20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.469
0.410
0.424
0.391

A
A
A

4NC54 31-0CH20
4NC54 33-0CH20
4NC54 34-0CH20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.644
0.667
0.713

4NC51 12-0BC20
Class 1
For circular conductors with max. diameter 17.5 mm
For 1 busbar up to max. 12 mm 10 mm

4NC51 17-0CC20

100
150
200
250

2.5
2.5
5
5

For circular conductors with max. diameter 28 mm


For 1 busbar up to max. 30 mm 10 mm
For 2 busbars up to max. 25 mm 5 mm

4NC52 22-0CE20

200
250
300
400

5
5
5
5

For circular conductors with max. diameter 36 mm


For 1 busbar up to max. 50 mm 10 mm
For 2 busbars up to max. 40 mm 5 mm
400
500
600
750

5
5
5
5

4NC53 25-0CE20
For circular conductors with max. diameter 45 mm
For 1 busbar up to max. 60 mm 10 mm
For 2 busbars up to max. 60 mm 10 mm
For 3 busbars up to max. 60 mm 5 mm
1000
1250
1500

10
10
10

4NC54 31-0CH20

* You can order this quantity or a multiple thereof.

2/92

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
Rated primary current Ipn

Rating Pn

VA

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Rated secondary current 5 A


Class 3
For circular conductors with max. diameter 17.5 mm
For 1 busbar up to max. 12 mm 10 mm
50
60
75

2.5
2.5
2.5

A
A
A

4NC51 12-2BC20
4NC51 13-2BC20
4NC51 15-2BC20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.426
0.430
0.431

A
A
A
A

4NC51 17-2CC20
4NC51 21-2CC20
4NC51 22-2CE20
4NC51 23-2CE20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.340
0.327
0.339
0.345

A
A
A
A

4NC52 22-2CE20
4NC52 23-2CE20
4NC52 24-2CE20
4NC52 25-2CE20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.467
0.474
0.356
0.379

A
A
A
A

4NC53 25-2CE20
4NC53 26-2CE20
4NC53 27-2CE20
4NC53 28-2CE20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.452
0.406
0.425
0.379

A
A
A

4NC54 31-2CH20
4NC54 33-2CH20
4NC54 34-2CH20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.660
0.631
0.669

4NC51 12-2BC20
Class 1
For circular conductors with max. diameter 17.5 mm
For 1 busbar up to max. 12 mm 10 mm

4NC51 17-2CC20

100
150
200
250

2.5
2.5
5
5

For circular conductors with max. diameter 28 mm


For 1 busbar up to max. 30 mm 10 mm
For 2 busbars up to max. 25 mm 5 mm

4NC52 22-2CE20

200
250
300
400

5
5
5
5

For circular conductors with max. diameter 36 mm


For 1 busbars up to max. 50 mm 10 mm
For 2 busbars up to max. 40 mm 5 mm
400
500
600
750

5
5
5
5

4NC53 25-2CE20
For circular conductors with max. diameter 45 mm
For 1 busbar up to max. 60 mm 10 mm
For 2 busbars up to max. 60 mm 10 mm
For 3 busbars up to max. 60 mm 5 mm
1000
1250
1500

10
10
10

4NC54 31-2CH20

4NC51 window-type current transformers, used as pin-wound transformers, Classes 1 and 3, from 5 A to 75 A
Pin-winding increases the primary current of the current transformer. Consequently, window-type current transformers can
also be used for low primary currents.
Basic type
Rated primary
current
Rating
Primary current to
be measured

4NC51 used as pinwound transformer

4NC51 17
100

4NC51 21
150

4NC51 22
200

4NC51 23
250

2.5

2.5

A
5
10
15

2.5
2.5
2.5
Number of required pin windings
Class 3
10
--5
6
--4
5

Class 1
-10
--

--10

----

----

20
25
30

-2
--

3
-2

-3
--

5
4
--

-6
5

10
8
--

-8
--

40
50
75

----

----

----

-2
--

-3
2

5
4
--

-5
--

A
VA

4NC51 12
50

4NC51 13
60

4NC51 15
75

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/93

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Accessories and spare parts
Version

DT

For VL160X (3VL1)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Further accessories
3- or 4-pole
Masking frames (cover frames) for door cutouts
A
IP40

Fixed-mounted or plug-in circuit breaker

3VL9 300-8BC00

1 unit

113

0.038

B1)
IP40

Fixed-mounted, plug-in or withdrawable circuit


breaker with front-operated rotary operating
mechanism or motorized operating mechanism
A

3VL9 300-8BG00

1 unit

113

0.099

C
IP20

Withdrawable circuit breaker with toggle lever


actuation. Assembly kit contains masking
frame and extended escutcheon
(cannot be used together with a motorized
operating mechanism/rotary operating mechanism)

--

D
IP40

Fixed-mounted circuit breaker or


plug-in circuit breaker
RCD circuit breaker masking frame

3VL9 300-8BD00

1 unit

113

0.034

RCD masking frame

3VL9 300-8BD00

1 unit

113

0.034

PU
Price (UNIT,
SET,
M)
per PU

PS*/
P. unit

PG

Weight
per PU
approx.

NSE-00574

Masking frame A

NSE-00575

Masking frame B

E 1)
IP40

Circuit breaker with RCD module and


front-operated rotary operating mechanism.
Assembly kit contains masking frame and
extended escutcheon

--

Circuit breaker with RCD module and


motorized operating mechanism.
Assembly kit contains masking frame and
extended escutcheon

--

Masking frame C
Version

DT

For VL400 (3VL4)


Order No.

kg

Further accessories
3- or 4-pole
Masking frames (cover frames) for door cutouts
A
IP40

Fixed-mounted or plug-in circuit breaker

3VL9 400-8BC00

1 unit

113

0.027

B1)
IP40

Fixed-mounted, plug-in or withdrawable circuit


breaker with front-operated rotary operating
mechanism or motorized operating mechanism
A

3VL9 400-8BG00

1 unit

113

0.149

C
IP20

Withdrawable circuit breaker with toggle lever


actuation. Assembly kit contains masking
frame and extended escutcheon
(cannot be used together with a motorized
operating mechanism/rotary operating mechanism)
A

3VL9 400-8BH00

1 unit

113

0.426

D
IP40

Fixed-mounted circuit breaker or


plug-in circuit breaker
RCD circuit breaker masking frame

3VL9 400-8BC00

1 unit

113

0.027

RCD masking frame

3VL9 400-8BD00

1 unit

113

0.047

circuit breaker with RCD module and


front-operated rotary operating mechanism.
Assembly kit contains masking frame and
extended escutcheon

3VL9 400-8BH00

1 unit

113

0.426

circuit breaker with RCD module and


motorized operating mechanism.
Assembly kit contains masking frame and
extended escutcheon

3VL9 400-8BJ00

1 unit

113

0.395

NSE-00577

Masking frame D

E1)
IP40
NSE-00578

Masking frame E

1)

For withdrawable version IP20.

* You can order this quantity or a multiple thereof.

2/94

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL160 (3VL2)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight DT
per PU
approx.

For VL250 (3VL3)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

3VL9 300-8BC00

1 unit

113

0.038 A

3VL9 300-8BC00

1 unit

113

0.038

3VL9 300-8BG00

1 unit

113

0.099 A

3VL9 300-8BG00

1 unit

113

0.099

3VL9 300-8BH00

1 unit

113

0.267 A

3VL9 300-8BH00

1 unit

113

0.267

3VL9 300-8BD00

1 unit

113

0.034 A

3VL9 300-8BD00

1 unit

113

0.034

3VL9 300-8BD00

1 unit

113

0.034 A

3VL9 300-8BD00

1 unit

113

0.034

3VL9 300-8BH00

1 unit

113

0.267 A

3VL9 300-8BH00

1 unit

113

0.267

3VL9 300-8BJ00

1 unit

113

0.230 A

3VL9 300-8BJ00

1 unit

113

0.230

DT

For VL630 (3VL5)

PG

Weight DT
per PU
approx.

For VL800 (3VL6)

Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.
kg

3VL9 600-8BC00

1 unit

113

0.055 A

3VL9 600-8BC00

1 unit

113

0.055

3VL9 600-8BG00

1 unit

113

0.177 A

3VL9 600-8BG00

1 unit

113

0.177

3VL9 600-8BH00

1 unit

113

0.575 A

3VL9 600-8BH00

1 unit

113

0.575

--

--

--

--

--

--

--

--

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/95

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Accessories and spare parts
Version

DT

For VL1250 (3VL7)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Further accessories
3- or 4-pole
Masking frames (cover frames) for door cutouts
A
IP40

Fixed-mounted or plug-in circuit breaker

3VL9 800-8BC00

1 unit

113

0.043

B1)
IP40

Fixed-mounted, plug-in or withdrawable


circuit breaker with front-operated rotary
operating mechanism or
motorized operating mechanism

3VL9 800-8BG00

1 unit

113

0.192

Withdrawable circuit breaker with toggle


lever actuation. Assembly kit contains
masking frame and extended escutcheon
(cannot be used together with a motorized
operating mechanism/rotary operating
mechanism)
A

3VL9 800-8BH00

1 unit

113

0.531

Fixed-mounted circuit breaker or


plug-in circuit breaker
RCD circuit breaker masking frame

--

RCD masking frame

--

Circuit breaker with RCD module and


front-operated rotary operating mechanism.
Assembly kit contains masking frame and
extended escutcheon

--

Circuit breaker with RCD module and


motorized operating mechanism.
Assembly kit contains masking frame and
extended escutcheon

--

NSE-00574

Masking frame A

NSE-00575

Masking frame B
C
IP20

Masking frame C
D
IP40

NSE-00577

Masking frame D
E1)
IP40

NSE-00578

Masking frame E
1)

For withdrawable version IP20.

* You can order this quantity or a multiple thereof.

2/96

Siemens LV 10.1 2011

Siemens AG 2011

Molded Case Circuit Breakers


3VL Molded Case Circuit Breakers up to 1600 A
Accessories and spare parts
DT

For VL1600 (3VL8)


Order No.

PU
Price (UNIT,
per PU SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3VL9 800-8BC00

1 unit

113

0.043

3VL9 800-8BG00

1 unit

113

0.192

3VL9 800-8BH00

1 unit

113

0.531

---

--

--

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

2/97

Siemens AG 2011

Molded Case Circuit Breakers


2

3VL Molded Case Circuit Breakers up to 1600 A


Accessories and spare parts
Version

DT Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Accessories for communication


3- or 4-pole
Data transmission through COM20, COM21
VL160 (3VL2) to VL1600 (3VL8)
COM20 (PROFIBUS module for SENTRON 3VL)
for ETU release with communication function
Module for connecting the SENTRON 3VL to the PROFIBUS DP,
including switching function and Zone Selective Interlocking functionality,
connection cable to ETU included in delivery of the ETU, length 1.5 m.

3VL9 000-8AU00

1 unit

113

1.038

COM21 (MODBUS module for SENTRON 3VL)


for ETU release with communication function
Module for connecting the SENTRON 3VL to the MODBUS RTU,
including switching function and Zone Selective Interlocking functionality,
connection cable to ETU included in delivery of the ETU, length 1.5 m.

3VL9 000-8AV00

1 unit

113

1.038

A
A
A

3VL9 000-8AQ61
3VL9 000-8AQ71
3VL9 000-8AQ81

1
1
1

1 unit
1 unit
1 unit

113
113
113

0.210
0.210
0.210

3UF7 910-0AA00-0

1 unit

131

0.030

3WL9 111-0AT28-0AA0

1 unit

103

0.900

BDA Plus1)
Same as BDA, but with additional Ethernet interface for connection to
Ethernet/Intranet/Internet

3WL9 111-0AT33-0AA0

1 unit

103

1.200

Connection cables for BDA and BDA Plus


Connection cables for connection of BDA and BDA Plus to LCD ETU release of the
SENTRON 3VL circuit breaker; length 1 m

3WL9 111-0BC20-0AA0

1 unit

103

0.200

3ZS2 311-0CC10-0YA0

1 unit

133

0.200

Connection cable ETU COM20/COM21


For VL400, length 3 m
For VL630 ... VL1600, length 3 m
For VL160 ... VL250, length 3 m
Addressing plugs
for assigning the PROFIBUS addresses without using a PC/PG
On COM20/COM21 through the system interface
Breaker Data Adapter (BDA)1)
Parameterization, operation, monitoring and diagnostics of SENTRON circuit
breakers using the local interface; Breaker Data Adapter, connection cable to the
SENTRON 3WL circuit breaker and to the programming device (e.g. notebook);
can be run with Internet Explorer with JAVA2 VM 1.4.0-01 and higher

Switch ES Power parameterization software


Parameterization, operation, monitoring, and diagnostics of SENTRON circuit break- A
ers via PROFIBUS DP; runs under Windows 95, Windows 98, Windows NT, Windows
2000 and Windows XP Professional, requires additional PROFIBUS card e.g. CP5613
1)

A 24 V DC power supply unit is required.

Communication:
For molded case circuit breakers with communication function
see pages 2/12 to 2/28 and 2/40 to 2/50.
For more information see also chapters "Measuring Devices
and E-Counters" and "Software".

More information
Manual for the SENTRON 3VL circuit breakers

SENTRON manual for communication solutions

This manual contains additional technical information, covering


a product description, mode of operation, electrical wiring system and retrofitting.

Free download from www.siemens.com/lowvoltage/manuals


See also "3WL Air Circuit Breakers/Non-Automatic Air Circuit
Breakers up to 6300 A (AC)", "Accessories and spare parts".

The manual and operating instructions are available in PDF format at: www.siemens.com/lowvoltage/manuals

* You can order this quantity or a multiple thereof.

2/98

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


3/2

Introduction

3/4

5SL Miniature Circuit Breakers


6000 A N

3/8
3/11
3/15
3/16
3/18
3/21

5SY and 5SP Miniature


Circuit Breakers
Introduction
5SY4, 10000 A
5SP4, high-current, 10000 A
5SP5, 5SY5, UC, 10000 A
5SY7, 15000 A
5SY8, 25 kA

3/23

5SJ6 . . .-.KS Miniature Circuit


Breakers with Plug-In Terminals

3/26

5SY6 0 Miniature Circuit Breakers,


1+N in 1 MW

3/29

Additional Components

3/37
3/43

Busbars
Standard 5ST3 6, 5ST3 7
According to UL 508, 5ST3 7. .-.HG

3/46

5SJ4 . . .-.HG Miniature Circuit


Breakers and Accessories,
acc. to UL 489 and IEC

3/55

5SP3 Main Miniature Circuit


Breakers, SHU

3/58

5SK9 Circuit Breaker Terminals


Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Introduction

Page

Field of application

Residential
buildings

Industry

Overview
Non-residential
buildings

Devices

Standards

5SL miniature circuit breakers,


6000 A

3/4

For all 0.3 to 63 A applications with B


EN 60898-1
and C tripping characteristics with
6000 A rated switching capacity acc. to
EN 60898-1.

5SY and 5SP miniature circuit


breakers

3/8

For all applications from 0.3 to 125 A


with a rated switching capacity of
10000 A and 15000 A acc. to
EN 60898-1. Applications for universal
current and from 0.3 to 63 A,
Version 25 kA, acc. to EN 60947-2.

5SJ6 . . .-.KS miniature circuit


breakers with plug-in terminals

3/23

For socket outlet and lighting circuits in EN 60898-1


all building installations.

EN 60898-1/2;
EN 60947-2

Used in

The plug-in terminals offer easy front


connection for manual insertion of conductors, which considerably reduces
mounting times.

5SY6 0 miniature circuit breakers,


1+N in 1 MW

3/26

For socket outlet and lighting circuits in EN 60898-1


all building installations where a switchable neutral conductor is required.
The miniature circuit breaker 1+N saves
space in the distribution board.

3/2

Additional components

3/29

Auxiliary switches, fault signal contacts,


shunt trips, undervoltage releases for
higher plant availability, RC units for
personal safety and remote controlled
mechanisms for remote switching.

--

Busbars

3/37

Busbars in 10 mm and 16 mm save


space in the distribution board and time
during mounting.

5SJ4 . . .-.HG miniature circuit


breakers and accessories,
acc. to UL 489 and IEC

3/46

Miniature circuit breakers can be used UL 489


as "branch circuit protection" and are
approved for the connection type "same
polarity" and "opposite polarity" in the
characteristics B, C and D acc. to
UL 489, from 0.3 to 63 A.

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Introduction

5SK9 circuit breaker terminals

3/58

Standards

Used in

Industry

5SP3 main miniature circuit breakers, 3/55


SHU

Field of application

Residential
buildings

Page

Non-residential
buildings

Devices

Voltage-independent selective main


DIN VDE 0641-21
miniature circuit breakers (SHU) in the
precounter sector support downstream
miniature circuit breakers by providing
better current limitation.

--

Circuit breaker terminals are used for


short-circuit protection or for protection
against overload and short circuits in
auxiliary and control circuits downstream of control transformers.

--

--

Siemens LV 10.1 2011

3/3

Siemens AG 2011

Miniature Circuit Breakers


5SL Miniature Circuit Breakers
6000 A

Overview
The new 5SL miniature circuit breaker is intended for use up to
6 kA. The devices have the system features characteristic of all
Siemens miniature circuit breakers.
The 5SL miniature circuit breakers can be used as main
switches for the disconnection or isolation of plants. They are
also suitable for the quick and easy mounting of additional components, such as auxiliary switches and fault signal contacts.

N
To facilitate cable entry, the devices are equipped with square
terminals for the joint accommodation of pin busbars with cables
from 0.75 mm2 to 35 mm2. The rated current range is between
0.3 and 63 A. The 5SL miniature circuit breakers are available in
characteristics B and C.

Benefits

Attractive device design


Easily recognizable, color-coded switching position indication
integrated in the handle.

Ergonomic handle and enclosure for user-friendly switching.

Square terminal version for joint accommodation of pin busbars with cables.

Easy-to-mount busbar assembly


Consistent bus-mounting concept throughout the Siemens
miniature circuit breaker range.

Effective touch protection when grasping and manually operating the latching slide with latch-down option.

Terminal for the accommodation of 2 cables of the same


cross-section (solid up to 2 x 10 mm2, finely stranded with end
sleeve, up to 2 x 4 mm2).

3/4

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SL Miniature Circuit Breakers

6000 A

Individual devices can be removed from the bus-mounted assembly without the use of tools.

The 5SL miniature circuit breakers are ideal for the quick and
easy mounting of auxiliary switches and fault signal contacts.

Technical specifications
5SL6
Standards

EN 60898-1

Approvals

See annex, chapter 20


B, C

Tripping characteristic
V AC

230/400

Min.

V AC/DC

24

Max.
Max.

V AC
V DC/pole

250/440
601)

kA AC

V AC

250/440
2/III

Rated voltage Un
Operational voltage

Rated switching capacity Icn

Acc. to EN 60898-1

Insulation coordination
Rated insulation voltage
Pollution degree for overvoltage category
Touch protection

Acc. to EN 50274

Yes

Handle end position, sealable

Yes

Degree of protection

IP20, with connected conductors

CFC and silicone-free

Yes

Conductor cross-sections

Solid and stranded


Finely stranded with end sleeve

mm2
mm2

0.75 ... 35
0.75 ... 25

Nm

2.5 ... 3

Terminals
Terminal tightening torque

Any

Mounting position
Service life, on average, with rated load

20000 actuations
C

Ambient temperature
Resistance to climate

Acc. to IEC 60068-2-30

Resistance to vibrations

Acc. to IEC 60068-2-6

1)

-25 ... +45, occasionally +55, max. 95 % humidity,


storage temperature: -40 ... +75
6 cycles

m/s2

50 at 25 ... 150 Hz and 60 at 35 Hz (4 sec)

The operational voltage 60 V DC/pole takes into account a battery charging voltage with a peak value of 72 V.

Siemens LV 10.1 2011

3/5

Siemens AG 2011

Miniature Circuit Breakers


5SL Miniature Circuit Breakers

6000 A

Selection and ordering data


6 000
3

Characteristic B
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic C
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 6000 A
1P, 230/400 V AC
0.3
0.5
1

1.6
2
3

----

A
A
A

5SL6 114-7
5SL6 105-7
5SL6 101-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.165
0.165
0.165

----

A
A
A

5SL6 115-7
5SL6 102-7
5SL6 103-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.165
0.165
0.165

4
6
8

-5SL6 106-6
--

A
002 A
A

5SL6 104-7
5SL6 106-7
5SL6 108-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.165
0.165
0.165

10
13
16

A
A
A

5SL6 110-6
5SL6 113-6
5SL6 116-6

002 A
002 A
002 A

5SL6 110-7
5SL6 113-7
5SL6 116-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.165
0.165
0.165

20
25
32

A
A
A

5SL6 120-6
5SL6 125-6
5SL6 132-6

002 A
002 A
002 A

5SL6 120-7
5SL6 125-7
5SL6 132-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.165
0.120
0.165

40
50
63

A
A
A

5SL6 140-6
5SL6 150-6
5SL6 163-6

002 A
002 A
002 A

5SL6 140-7
5SL6 150-7
5SL6 163-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.165
0.165
0.165

----

A
A
A

5SL6 514-7
5SL6 505-7
5SL6 501-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

----

A
A
A

5SL6 515-7
5SL6 502-7
5SL6 503-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

1P+N, 230 V AC
0.3
0.5
1

1.6
2
3
4
6
8

-5SL6 506-6
--

A
002 A
A

5SL6 504-7
5SL6 506-7
5SL6 508-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

10
13
16

A
A
A

5SL6 510-6
5SL6 513-6
5SL6 516-6

002 A
002 A
002 A

5SL6 510-7
5SL6 513-7
5SL6 516-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

20
25
32

A
A
A

5SL6 520-6
5SL6 525-6
5SL6 532-6

002 A
002 A
002 A

5SL6 520-7
5SL6 525-7
5SL6 532-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

40
50
63

A
A
A

5SL6 540-6
5SL6 550-6
5SL6 563-6

002 A
002 A
002 A

5SL6 540-7
5SL6 550-7
5SL6 563-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

----

A
A
A

5SL6 214-7
5SL6 205-7
5SL6 201-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

----

A
A
A

5SL6 215-7
5SL6 202-7
5SL6 203-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

2P, 400 V AC
0.3
0.5
1

1.6
2
3

1)

4
6
8

-5SL6 206-6
--

A
002 A
A

5SL6 204-7
5SL6 206-7
5SL6 208-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

10
13
16

A
A
A

5SL6 210-6
5SL6 213-6
5SL6 216-6

002 A
002 A
002 A

5SL6 210-7
5SL6 213-7
5SL6 216-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

20
25
32

A
A
A

5SL6 220-6
5SL6 225-6
5SL6 232-6

002 A
002 A
002 A

5SL6 220-7
5SL6 225-7
5SL6 232-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.240
0.330

40
50
63

A
A
A

5SL6 240-6
5SL6 250-6
5SL6 263-6

002 A
002 A
002 A

5SL6 240-7
5SL6 250-7
5SL6 263-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.330
0.330
0.330

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/6

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SL Miniature Circuit Breakers

N
6 000
3

6000 A

Characteristic B
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic C
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 6000 A
3P, 400 V AC
0.3
0.5
1

1.6
2
3

----

A
A
A

5SL6 314-7
5SL6 305-7
5SL6 301-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.465
0.465
0.465

----

A
A
A

5SL6 315-7
5SL6 302-7
5SL6 303-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.465
0.465
0.465

4
6
8

-5SL6 306-6
--

A
002 A
A

5SL6 304-7
5SL6 306-7
5SL6 308-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.465
0.465
0.465

10
13
16

A
A
A

5SL6 310-6
5SL6 313-6
5SL6 316-6

002 A
002 A
002 A

5SL6 310-7
5SL6 313-7
5SL6 316-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.465
0.465
0.360

20
25
32

A
A
A

5SL6 320-6
5SL6 325-6
5SL6 332-6

002 A
002 A
002 A

5SL6 320-7
5SL6 325-7
5SL6 332-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.465
0.465
0.465

40
50
63

A
A
A

5SL6 340-6
5SL6 350-6
5SL6 363-6

002 A
002 A
002 A

5SL6 340-7
5SL6 350-7
5SL6 363-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.465
0.465
0.465

----

A
A
A

5SL6 614-7
5SL6 605-7
5SL6 601-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

----

A
A
A

5SL6 615-7
5SL6 602-7
5SL6 603-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

3P+N, 400 V AC
0.3
0.5
1

1.6
2
3
4
6
8

-5SL6 606-6
--

A
002 A
A

5SL6 604-7
5SL6 606-7
5SL6 608-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

10
13
16

A
A
A

5SL6 610-6
5SL6 613-6
5SL6 616-6

002 A
002 A
002 A

5SL6 610-7
5SL6 613-7
5SL6 616-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

20
25
32

A
A
A

5SL6 620-6
5SL6 625-6
5SL6 632-6

002 A
002 A
002 A

5SL6 620-7
5SL6 625-7
5SL6 632-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

40
50
63

A
A
A

5SL6 640-6
5SL6 650-6
5SL6 663-6

002 A
002 A
002 A

5SL6 640-7
5SL6 650-7
5SL6 663-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

----

A
A
A

5SL6 414-7
5SL6 405-7
5SL6 401-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

----

A
A
A

5SL6 415-7
5SL6 402-7
5SL6 403-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

4P, 400 V AC
0.3
0.5
1

1.6
2
3

1)

4
6
8

-5SL6 406-6
--

A
002 A
A

5SL6 404-7
5SL6 406-7
5SL6 408-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

10
13
16

A
A
A

5SL6 410-6
5SL6 413-6
5SL6 416-6

002 A
002 A
002 A

5SL6 410-7
5SL6 413-7
5SL6 416-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

20
25
32

A
A
A

5SL6 420-6
5SL6 425-6
5SL6 432-6

002 A
002 A
002 A

5SL6 420-7
5SL6 425-7
5SL6 432-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

40
50
63

A
A
A

5SL6 440-6
5SL6 450-6
5SL6 463-6

002 A
002 A
002 A

5SL6 440-7
5SL6 450-7
5SL6 463-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/7

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
Introduction

Overview
MCBs are used to protect plants in buildings and for industrial
applications. The devices can be used as main control switches
for the disconnection or isolation of plants.

The devices are approved for worldwide use according to IEC


standards for systems up to 250/440 V AC. 60 V DC per pole is
permitted in DC systems.

Used in industrial applications and plant engineering, miniature


circuit breakers can be supplemented with additional components, such as auxiliary switches, fault signal contacts, shunt
trips, undervoltage releases, remote controls and RC units.

For North America, we also have additional certification to


UL 1077 for use as "supplementary protectors" in systems up to
480Y/277 V AC. For use in ship building, the devices also have
numerous certifications according to shipping classifications;
BV, DNV, GL and LRS. References to this can be found in the
annex, chapter 20.

Benefits

Optional top or bottom infeed as the terminals are identical


Clear and visible conductor connection in front of the busbar
facilitates controls
The conductor is easily inserted into the terminal thanks to the
large and easily accessible wiring space.

Integrated movable terminal covers located at the cable entries ensure the terminals are fully insulated when the screws
are tightened
The effective touch protection when grasping the device considerably exceeds the requirements of VBG 4/BGV A3.

Manual snap-on fixing and release systems that require no


tools enable fast assembly and disassembly of MCBs
Marked labeling field on all modular installation devices for
uniform, quick and easy identification.

Quick and easy manual removal of MCBs from the busbar assembly if e. g. connections need to be changed
Time-saving replacement of parts as busbars no longer need
to be freed from adjacent devices.

3/8

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
Introduction

Duplicate terminal clamps allow 2 conductors with different


cross-sections (cross-section combinations upon request) to
be fitted.

The 5SY miniature circuit breakers are ideal for the quick and
easy mounting of auxiliary switches and fault signal contacts.
Captive metal brackets on additional components ensure the
quick and easy mounting of devices on the miniature circuit
breakers without the need for tools.

Siemens LV 10.1 2011

3/9

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
Introduction

Technical specifications
Standards

5SY4

5SY5

5SY7

5SY8

5SP4

5SP5

EN 60898-1;
EN 60947-2

EN 60898-2

EN 60898-1;
EN 60947-2

EN 60947-2

EN 60898-1;
EN 60947-2

EN 60898-2

See annex, chapter 20

Approvals
Operational voltage

V AC
V DC

230/400
--

230/400
220/440/880

230/400
--

230/400
--

230/400
--

230/400
220/440

Min.

V AC/DC

24

24

24

24

24

24

Acc. to EN 60898-1/-2 and EN 60947-2

Max.
Max.

V DC/pole
V AC

601)
250/440

250
250/440

601)
250/440

601)
250/440

601)
250/440

250
250/440

Acc. to UL 1077 and CSA C22.2 No.235

Max.

V AC
V DC/pole

480Y/277
60

---

480Y/277
60

480Y/277
60

480Y/277
60

---

Icn acc. to IEC/EN 60898-1

kA AC

10

10

15

--

10

Icn acc. to IEC/EN 60898-2


Icu acc. to IEC/EN 60947-2

kA DC

10

10

15

--

10

10

kA AC
kA DC

---

-15

---

25
15

---

-15

kA AC

--

--

V AC
V DC/pole

250/440
--

250

--

--

--

250

Rated switching capacity2)

Acc. to UL1077 and CSA C22.2 No.235


Insulation coordination
Rated insulation voltage

3/III

Pollution degree for overvoltage category


Touch protection

Acc. to EN 50274

Yes

Main switch characteristics according to EN 60204

Yes

Handle end position, sealable

Yes

Degree of protection

Acc. to EN 60529

IP20, with connected conductors


Yes

CFC and silicone-free


Mounting
Snap-on fixing system

Yes

--

Standard mounting rail and screw fixing

--

Yes

Tunnel terminals at both ends

--

Yes

Combined terminals at both ends

Yes

--

Nm
lb. in

2.5 ... 3
22 ... 26

2.5 ... 3.5


22 ... 31

Terminals

Terminal tightening torque


Conductor cross-sections
Solid and stranded

mm2

0.75 ... 35

0.75 ... 50

Finely stranded, with end sleeve

mm2

0.75 ... 25

0.75 ... 35

AWG cables

AWG

14 ... 4

14 ... 2

Mains connection
AC

Any

DC

Any

Mounting position

Any

3)

Any

Service life
On average, with rated load

Actuations
Actuations

20000
For 5SY5 at 40 A, 50 A and 63 A 10000

Ambient temperature

-25 ... +45, occasionally +55, max. 95 % humidity

Storage temperature

-40 ... +75

Resistance to climate

Acc. to IEC 60068-2-30

Shock

Acc. to IEC 60068-2-27 m/s2

6 cycles

Resistance to vibrations

Acc. to IEC 60068-2-6

m/s2

150 at 11ms half-sine


50 at 25 ... 150 Hz and 60 at 35 Hz (4 sec)

1)

The operational voltage 60 V DC/pole takes into account a battery charging voltage with a peak value of 72 V.

2)

For detailed information, see engineering manual at:


www.siemens.com/lowvoltage/manuals.

3)

Ensure compliance with the specified polarity when connecting DC.

3/10

Siemens LV 10.1 2011

3)

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY4, 10 000 A

Selection and ordering data


10 000
3

Characteristic A
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic B
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A
1P, 230/400 V AC
0.5
1
1.6

A
}
B

5SY4 105-5
5SY4 101-5
5SY4 115-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

0.165
0.167
0.165

2
3
4

}
}
}

5SY4 102-5
5SY4 103-5
5SY4 104-5

001
001
001

----

1
1 unit
1
1 unit
1 1/12 units

0.166
0.168
0.152

6
8
10

}
B
}

5SY4 106-5
5SY4 108-5
5SY4 110-5

001 }
001
001 }

5SY4 106-6
-5SY4 110-6

1 1/12 units
1
1 unit
1 1/12 units

002
002

0.147
0.162
0.146

13
16
20

C
}
A

5SY4 113-5
5SY4 116-5
5SY4 120-5

001 }
001 }
001 }

5SY4 113-6
5SY4 116-6
5SY4 120-6

1
1 unit
1 1/12 units
1
1 unit

002
002
002

0.161
0.154
0.160

25
32
40

A
B
B

5SY4 125-5
5SY4 132-5
5SY4 140-5

001 }
001 }
001 B

5SY4 125-6
5SY4 132-6
5SY4 140-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.163
0.165
0.164

50
63
80

C
C

5SY4 150-5
5SY4 163-5
--

001 B
001 B
C

5SY4 150-6
5SY4 163-6
5SY4 180-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.168
0.173
0.159

C
B
B

5SY4 501-5
5SY4 515-5
5SY4 502-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

3
4
6

C
B
C

5SY4 503-5
5SY4 504-5
5SY4 506-5

001
001
001 }

--5SY4 506-6

1
1
1

1 unit
1 unit
1 unit

002

0.330
0.319
0.315

8
10
13

C
B
C

5SY4 508-5
5SY4 510-5
5SY4 513-5

001
001 }
001 }

-5SY4 510-6
5SY4 513-6

1
1
1

1 unit
1 unit
1/6 units

002
002

0.316
0.312
0.315

16
20
25

C
C
C

5SY4 516-5
5SY4 520-5
5SY4 525-5

001 }
001 B
001 B

5SY4 516-6
5SY4 520-6
5SY4 525-6

1
1
1

1/6 units
1 unit
1 unit

002
002
002

0.311
0.316
0.317

32
40
50

C
C
C

5SY4 532-5
5SY4 540-5
5SY4 550-5

001 B
001 C
001 C

5SY4 532-6
5SY4 540-6
5SY4 550-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.325
0.307
0.319

63

5SY4 563-5

001 C

5SY4 563-6

1 unit

002

0.346

C
B
B

5SY4 205-5
5SY4 201-5
5SY4 215-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

0.330
0.327
0.324

2
3
4

}
B
}

5SY4 202-5
5SY4 203-5
5SY4 204-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

0.325
0.324
0.322

6
8
10

}
C
}

5SY4 206-5
5SY4 208-5
5SY4 210-5

001 }
001
001 }

5SY4 206-6
-5SY4 210-6

1
1
1

1 unit
1 unit
1/6 units

002
002

0.314
0.300
0.306

13
16
20

C
}
B

5SY4 213-5
5SY4 216-5
5SY4 220-5

001 B
001 }
001 }

5SY4 213-6
5SY4 216-6
5SY4 220-6

1
1
1

1 unit
1/6 units
1 unit

002
002
002

0.315
0.295
0.313

25
32
40

B
A
B

5SY4 225-5
5SY4 232-5
5SY4 240-5

001 }
001 B
001 B

5SY4 225-6
5SY4 232-6
5SY4 240-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.318
0.323
0.323

50
63
80

C
C

5SY4 250-5
5SY4 263-5
--

001 B
001 B
C

5SY4 250-6
5SY4 263-6
5SY4 280-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.330
0.342
0.328

1P+N, 230 V AC
1
1.6
2

0.330
0.325
0.325

2P, 400 V AC
0.5
1
1.6

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/11

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY4, 10 000 A

10 000
3

Characteristic A
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic B
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A
3P, 400 V AC
0.5
1
1.6

C
A
C

5SY4 305-5
5SY4 301-5
5SY4 315-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

0.495
0.482
0.477

2
3
4

B
A
B

5SY4 302-5
5SY4 303-5
5SY4 304-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

0.485
0.490
0.456

6
8
10

B
C
B

5SY4 306-5
5SY4 308-5
5SY4 310-5

001 }
001
001 }

5SY4 306-6
-5SY4 310-6

1
1
1

1 unit
1 unit
1 unit

002
002

0.467
0.478
0.463

13
16
20

C
A
B

5SY4 313-5
5SY4 316-5
5SY4 320-5

001 B
001 }
001 }

5SY4 313-6
5SY4 316-6
5SY4 320-6

1
1
1

1 unit
1/4 units
1 unit

002
002
002

0.469
0.439
0.465

25
32
40

B
B
B

5SY4 325-5
5SY4 332-5
5SY4 340-5

001 }
001 }
001 }

5SY4 325-6
5SY4 332-6
5SY4 340-6

1
1
1

1 unit
1/4 units
1 unit

002
002
002

0.472
0.475
0.478

50
63
80

B
C

5SY4 350-5
5SY4 363-5
--

001 A
001 A
B

5SY4 350-6
5SY4 363-6
5SY4 380-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.490
0.499
0.481

C
C
C

5SY4 601-5
5SY4 615-5
5SY4 602-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

3
4
6

C
C
C

5SY4 603-5
5SY4 604-5
5SY4 606-5

001
001
001 B

--5SY4 606-6

1
1
1

1 unit
1 unit
1 unit

002

0.650
0.660
0.615

8
10
13

C
C
C

5SY4 608-5
5SY4 610-5
5SY4 613-5

001
001 B
001 C

-5SY4 610-6
5SY4 613-6

1
1
1

1 unit
1 unit
1 unit

002
002

0.660
0.616
0.625

16
20
25

C
C
C

5SY4 616-5
5SY4 620-5
5SY4 625-5

001 }
001 B
001 A

5SY4 616-6
5SY4 620-6
5SY4 625-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.616
0.611
0.632

32
40
50

C
C
C

5SY4 632-5
5SY4 640-5
5SY4 650-5

001 B
001 C
001 C

5SY4 632-6
5SY4 640-6
5SY4 650-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.636
0.608
0.631

63

5SY4 663-5

001 A

5SY4 663-6

1 unit

002

0.665

C
C
C

5SY4 401-5
5SY4 415-5
5SY4 402-5

001
001
001

----

1
1
1

1 unit
1 unit
1 unit

0.649
0.649
0.642

3
4
6

C
C
C

5SY4 403-5
5SY4 404-5
5SY4 406-5

001
001
001 A

--5SY4 406-6

1
1
1

1 unit
1 unit
1 unit

002

0.660
0.642
0.621

8
10
13

C
C
C

5SY4 408-5
5SY4 410-5
5SY4 413-5

001
001 B
001 C

-5SY4 410-6
5SY4 413-6

1
1
1

1 unit
1 unit
1 unit

002
002

0.601
0.609
0.650

16
20
25

C
C
C

5SY4 416-5
5SY4 420-5
5SY4 425-5

001 }
001 C
001 B

5SY4 416-6
5SY4 420-6
5SY4 425-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.612
0.619
0.617

32
40
50

C
C
C

5SY4 432-5
5SY4 440-5
5SY4 450-5

001 B
001 B
001 B

5SY4 432-6
5SY4 440-6
5SY4 450-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.636
0.634
0.645

63
80

5SY4 463-5
--

001 B
B

5SY4 463-6
5SY4 480-6

1
1

1 unit
1 unit

002
002

0.669
0.651

3P+N, 400 V AC
1
1.6
2

0.648
0.641
0.641

4P, 400 V AC
1
1.6
2

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/12

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY4, 10 000 A
10 000
3

In

Mount- DT
ing
width

MW1)

PG DT

Characteristic C
Order No.

Price
per PU

Characteristic D
Order No.

PU
Price (UNIT,
SET,
per PU
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A
1P, 230/400 V AC
0.3
0.5
1

B
}
}

5SY4 114-7
5SY4 105-7
5SY4 101-7

003 C
003 B
003 }

5SY4 114-8
5SY4 105-8
5SY4 101-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.167
0.166
0.165

1.6
2
3

A
}
}

5SY4 115-7
5SY4 102-7
5SY4 103-7

003 B
003 }
003 }

5SY4 115-8
5SY4 102-8
5SY4 103-8

1
1 unit
1 1/12 units
1
1 unit

004
004
004

0.163
0.155
0.160

4
5
6

}
C
}

5SY4 104-7
5SY4 111-7
5SY4 106-7

003 }
003
003 }

5SY4 104-8
-5SY4 106-8

1 1/12 units
1
1 unit
1
1 unit

004
004

0.158
0.149
0.159

8
10
13

}
}
}

5SY4 108-7
5SY4 110-7
5SY4 113-7

003 A
003 }
003 B

5SY4 108-8
5SY4 110-8
5SY4 113-8

1
1 unit
1 1/12 units
1
1 unit

004
004
004

0.156
0.155
0.156

15
16
20

C
}
C

5SY4 118-7
5SY4 116-7
5SY4 120-7

003
003 }
003 A

-5SY4 116-8
5SY4 120-8

1
1
1

1 unit
1 unit
1 unit

004
004

0.151
0.156
0.162

25
30
32

}
C
}

5SY4 125-7
5SY4 130-7
5SY4 132-7

003 B
003
003 B

5SY4 125-8
-5SY4 132-8

1
1
1

1 unit
1 unit
1 unit

35
40
45

B
}
B

5SY4 135-7
5SY4 140-7
5SY4 145-7

003
003 B
003

-5SY4 140-8
--

1
1
1

1 unit
1 unit
1 unit

50
60
63
80

A
B
B
B

5SY4 150-7
5SY4 160-7
5SY4 163-7
5SY4 180-7

003 B
003
003 B
003

5SY4 150-8
-5SY4 163-8
--

1
1
1
1

1 unit
1 unit
1 unit
1 unit

004

C
B
}

5SY4 514-7
5SY4 505-7
5SY4 501-7

003 C
003 C
003 B

5SY4 514-8
5SY4 505-8
5SY4 501-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.323
0.316
0.303

1.6
2
3

C
}
A

5SY4 515-7
5SY4 502-7
5SY4 503-7

003 C
003 A
003 B

5SY4 515-8
5SY4 502-8
5SY4 503-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.319
0.320
0.314

4
6
8

}
}
B

5SY4 504-7
5SY4 506-7
5SY4 508-7

003 B
003 A
003 C

5SY4 504-8
5SY4 506-8
5SY4 508-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.310
0.311
0.305

10
13
16

}
}
}

5SY4 510-7
5SY4 513-7
5SY4 516-7

003 }
003 B
003 A

5SY4 510-8
5SY4 513-8
5SY4 516-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.305
0.304
0.306

20
25
32

}
A
A

5SY4 520-7
5SY4 525-7
5SY4 532-7

003 B
003 B
003 B

5SY4 520-8
5SY4 525-8
5SY4 532-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.309
0.309
0.320

40
50
63
80

B
C
C
C

5SY4 540-7
5SY4 550-7
5SY4 563-7
5SY4 580-7

003 C
003 C
003 C
003

5SY4 540-8
5SY4 550-8
5SY4 563-8
--

1
1
1
1

1 unit
1 unit
1 unit
1 unit

004
004
004

0.312
0.322
0.332
0.321

A
}
}

5SY4 214-7
5SY4 205-7
5SY4 201-7

003 B
003 A
003 }

5SY4 214-8
5SY4 205-8
5SY4 201-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.325
0.325
0.320

1.6
2
3

}
}
}

5SY4 215-7
5SY4 202-7
5SY4 203-7

003 A
003 }
003 }

5SY4 215-8
5SY4 202-8
5SY4 203-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.319
0.318
0.313

4
5
6

}
C
}

5SY4 204-7
5SY4 211-7
5SY4 206-7

003 }
003
003 }

5SY4 204-8
-5SY4 206-8

1
1
1

1 unit
1 unit
1 unit

004
004

0.309
0.297
0.312

8
10
13

}
}
}

5SY4 208-7
5SY4 210-7
5SY4 213-7

003 A
003 }
003 A

5SY4 208-8
5SY4 210-8
5SY4 213-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.305
0.303
0.304

15
16
20

C
}
}

5SY4 218-7
5SY4 216-7
5SY4 220-7

003
003 }
003 }

-5SY4 216-8
5SY4 220-8

1
1
1

1 unit
1 unit
1 unit

004
004

0.294
0.305
0.317

25
30
32

}
B
}

5SY4 225-7
5SY4 230-7
5SY4 232-7

003 A
003
003 A

5SY4 225-8
-5SY4 232-8

1
1
1

1 unit
1 unit
1 unit

35
40
45

B
}
B

5SY4 235-7
5SY4 240-7
5SY4 245-7

003
003 A
003

-5SY4 240-8
--

1
1
1

1 unit
1 unit
1 unit

50
60
63
80

A
B
A
B

5SY4 250-7
5SY4 260-7
5SY4 263-7
5SY4 280-7

003 B
003
003 B
003

5SY4 250-8
-5SY4 263-8
--

1
1
1
1

1 unit
1 unit
1 unit
1/6 units

004
004
004

004

0.161
0.148
0.165
0.180
0.166
0.160
0.164
0.160
0.166
0.160

1P+N, 230 V AC
0.3
0.5
1

2P, 400 V AC
0.3
0.5
1

004
004
004
004
004

0.318
0.300
0.324
0.298
0.326
0.312
0.324
0.322
0.325
0.313

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/13

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY4, 10 000 A

10 000
3

Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A
3P, 400 V AC
0.3
0.5
1

C
B
}

5SY4 314-7
5SY4 305-7
5SY4 301-7

003 C
003 B
003 A

5SY4 314-8
5SY4 305-8
5SY4 301-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.481
0.474
0.478

1.6
2
3

C
}
}

5SY4 315-7
5SY4 302-7
5SY4 303-7

003 B
003 A
003 A

5SY4 315-8
5SY4 302-8
5SY4 303-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.474
0.476
0.466

4
5
6

}
C
}

5SY4 304-7
5SY4 311-7
5SY4 306-7

003 }
003
003 }

5SY4 304-8
-5SY4 306-8

1
1
1

1 unit
1 unit
1 unit

004
004

0.460
0.455
0.461

8
10
13

A
}
}

5SY4 308-7
5SY4 310-7
5SY4 313-7

003 B
003 }
003 B

5SY4 308-8
5SY4 310-8
5SY4 313-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.451
0.447
0.455

15
16
20

C
}
}

5SY4 318-7
5SY4 316-7
5SY4 320-7

003
003 }
003 }

-5SY4 316-8
5SY4 320-8

1
1
1

1 unit
1/4 units
1 unit

004
004

0.461
0.431
0.472

25
30
32

}
C
}

5SY4 325-7
5SY4 330-7
5SY4 332-7

003 }
003
003 C

5SY4 325-8
-5SY4 332-8

1
1
1

1 unit
1 unit
1 unit

35
40
45

C
}
B

5SY4 335-7
5SY4 340-7
5SY4 345-7

003
003 }
003

-5SY4 340-8
--

1
1
1

1 unit
1 unit
1 unit

50
60
63
80

}
C
}
B

5SY4 350-7
5SY4 360-7
5SY4 363-7
5SY4 380-7

003 }
003
003 }
003

5SY4 350-8
-5SY4 363-8
--

1
1
1
1

1 unit
1 unit
1 unit
1 unit

004

C
C
C

5SY4 614-7
5SY4 605-7
5SY4 601-7

003 C
003 C
003 C

5SY4 614-8
5SY4 605-8
5SY4 601-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.660
0.636

1.6
2
3

C
B
B

5SY4 615-7
5SY4 602-7
5SY4 603-7

003 C
003 C
003 C

5SY4 615-8
5SY4 602-8
5SY4 603-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.621
0.608
0.660

4
6
8

C
B
C

5SY4 604-7
5SY4 606-7
5SY4 608-7

003 C
003 C
003 C

5SY4 604-8
5SY4 606-8
5SY4 608-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.587
0.615
0.595

10
13
16

}
B
}

5SY4 610-7
5SY4 613-7
5SY4 616-7

003 B
003 C
003 }

5SY4 610-8
5SY4 613-8
5SY4 616-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.597
0.594
0.602

20
25
32

}
}
}

5SY4 620-7
5SY4 625-7
5SY4 632-7

003 B
003 A
003 A

5SY4 620-8
5SY4 625-8
5SY4 632-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.627
0.625
0.631

40
50
63
80

}
B
}
C

5SY4 640-7
5SY4 650-7
5SY4 663-7
5SY4 680-7

003 A
003 A
003 B
003

5SY4 640-8
5SY4 650-8
5SY4 663-8
--

1
1
1
1

1 unit
1 unit
1 unit
1 unit

004
004
004

0.633
0.641
0.639
0.640

C
C
C

5SY4 414-7
5SY4 405-7
5SY4 401-7

003 C
003 C
003 C

5SY4 414-8
5SY4 405-8
5SY4 401-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.639
0.633
0.636

1.6
2
3

C
B
C

5SY4 415-7
5SY4 402-7
5SY4 403-7

003 C
003 C
003 C

5SY4 415-8
5SY4 402-8
5SY4 403-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.623
0.630
0.660

4
6
8

B
}
C

5SY4 404-7
5SY4 406-7
5SY4 408-7

003 C
003 B
003 C

5SY4 404-8
5SY4 406-8
5SY4 408-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.610
0.610
0.571

10
13
16

}
C
}

5SY4 410-7
5SY4 413-7
5SY4 416-7

003 A
003 C
003 A

5SY4 410-8
5SY4 413-8
5SY4 416-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.597
0.571
0.600

20
25
32

}
}
}

5SY4 420-7
5SY4 425-7
5SY4 432-7

003 }
003 }
003 }

5SY4 420-8
5SY4 425-8
5SY4 432-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.626
0.617
0.640

40
50
63
80

}
}
}
B

5SY4 440-7
5SY4 450-7
5SY4 463-7
5SY4 480-7

003 A
003 }
003 }
003

5SY4 440-8
5SY4 450-8
5SY4 463-8
--

1
1
1
1

1 unit
1 unit
1 unit
1 unit

004
004
004

0.638
0.636
0.644
0.640

004
004
004

004

0.470
0.451
0.481
0.450
0.481
0.469
0.482
0.490
0.486
0.480

3P+N, 400 V AC
0.3
0.5
1

4P, 400 V AC
0.3
0.5
1

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/14

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SP4, high-current, 10 000 A

Selection and ordering data

Characteristic B

10 000
In

Mounting width

MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A, high current


1P, 230/400 V AC
80
100
125

1.5

B
C
B

5SP4 180-6
5SP4 191-6
5SP4 192-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.263
0.265
0.269

C
C
C

5SP4 280-6
5SP4 291-6
5SP4 292-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.532
0.527
0.534

4.5

B
B
C

5SP4 380-6
5SP4 391-6
5SP4 392-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.800
0.787
0.793

B
C
C

5SP4 480-6
5SP4 491-6
5SP4 492-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

1.046
1.038
1.062

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

2P, 400 V AC
80
100
125

3P, 400 V AC
80
100
125

4P, 400 V AC
80
100
125

Characteristic C

10 000
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

kg

MCBs 10000 A,
high current
1P, 230/400 V AC
80
100
125

1.5

A
A
A

5SP4 180-7
5SP4 191-7
5SP4 192-7

003 B
003 C
003

5SP4 180-8
5SP4 191-8
--

1
1
1

1 unit
1 unit
1 unit

004
004

0.257
0.254
0.248

A
A
A

5SP4 280-7
5SP4 291-7
5SP4 292-7

003 C
003 C
003

5SP4 280-8
5SP4 291-8
--

1
1
1

1 unit
1 unit
1 unit

004
004

0.505
0.515
0.521

}
}
A

5SP4 380-7
5SP4 391-7
5SP4 392-7

003 A
003 A
003

5SP4 380-8
5SP4 391-8
--

1
1
1

1 unit
1 unit
1 unit

004
004

0.762
0.783
0.787

A
A
A

5SP4 480-7
5SP4 491-7
5SP4 492-7

003 A
003 C
003

5SP4 480-8
5SP4 491-8
--

1
1
1

1 unit
1 unit
1 unit

004
004

1.031
1.033
1.031

2P, 400 V AC
80
100
125

3P, 400 V AC
80
100
125

4.5

4P, 400 V AC
80
100
125

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/15

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SP5, 5SY5, UC, 10 000 A

Selection and ordering data


10 000
3

Characteristic B
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic C
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A, UC
1P, 230/400 V AC,
220 V DC
0.3
0.5
1

1.6
2
3

C
B
}

5SY5 114-7
5SY5 105-7
5SY5 101-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.169
0.168
0.166

-5SY5 102-6
--

A
002 }
A

5SY5 115-7
5SY5 102-7
5SY5 103-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.164
0.167
0.162

---C

4
6
8

}
}

5SY5 104-6
5SY5 106-6
--

002 }
002 }
A

5SY5 104-7
5SY5 106-7
5SY5 108-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.163
0.163
0.162

10
13
16

}
C
A

5SY5 110-6
5SY5 113-6
5SY5 116-6

002 }
002 B
002 }

5SY5 110-7
5SY5 113-7
5SY5 116-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.160
0.164
0.161

20
25
32

C
C
C

5SY5 120-6
5SY5 125-6
5SY5 132-6

002 A
002 B
002 B

5SY5 120-7
5SY5 125-7
5SY5 132-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.163
0.165
0.164

40
50
63

C
C
C

5SY5 140-6
5SY5 150-6
5SY5 163-6

002 C
002 C
002 C

5SY5 140-7
5SY5 150-7
5SY5 163-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.164
0.171
0.169

----

B
B
B

5SP5 180-7
5SP5 191-7
5SP5 192-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.258
0.258
0.258

----

C
B
}

5SY5 214-7
5SY5 205-7
5SY5 201-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.333
0.328
0.324

----

B
}
}

5SY5 215-7
5SY5 202-7
5SY5 203-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.321
0.329
0.317

1P, 230/400 V AC,


220 V DC
80
100
125

1.5

2P, 400 V AC, 440 V DC


0.3
0.5
1

1.6
2
3
4
6
8

-5SY5 206-6
--

}
002 }
B

5SY5 204-7
5SY5 206-7
5SY5 208-7

1
1
1

1 unit
1/6 units
1 unit

003
003
003

0.319
0.300
0.313

10
13
16

}
C
}

5SY5 210-6
5SY5 213-6
5SY5 216-6

002 }
002 B
002 }

5SY5 210-7
5SY5 213-7
5SY5 216-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.314
0.322
0.314

20
25
32

A
A
B

5SY5 220-6
5SY5 225-6
5SY5 232-6

002 }
002 }
002 B

5SY5 220-7
5SY5 225-7
5SY5 232-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.319
0.321
0.322

40
50
63

C
C
C

5SY5 240-6
5SY5 250-6
5SY5 263-6

002 B
002 A
002 }

5SY5 240-7
5SY5 250-7
5SY5 263-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.323
0.333
0.342

B
B
B

5SP5 280-7
5SP5 291-7
5SP5 292-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.516
0.516
0.516

2P, 400 V AC, 440 V DC


80
100
125

----

For application examples, see engineering manual at:


www.siemens.com/lowvoltage/manuals.
1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/16

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SP5, 5SY5, UC, 10 000 A
10 000
3

Characteristic B
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic C
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 10000 A, UC
4P, 400 V AC, 880 V DC
0.3
0.5
1

1.6
2
3

----

C
C
C

5SY5 414-7
5SY5 405-7
5SY5 401-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

----

C
C
C

5SY5 415-7
5SY5 402-7
5SY5 403-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

4
6
8

-5SY5 406-6
--

C
002 C
C

5SY5 404-7
5SY5 406-7
5SY5 408-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

10
13
16

C
C
C

5SY5 410-6
5SY5 413-6
5SY5 416-6

002 C
002 C
002 C

5SY5 410-7
5SY5 413-7
5SY5 416-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

20
25
32

C
C
C

5SY5 420-6
5SY5 425-6
5SY5 432-6

002 C
002 C
002 C

5SY5 420-7
5SY5 425-7
5SY5 432-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

40
50
63

C
C
C

5SY5 440-6
5SY5 450-6
5SY5 463-6

002 C
002 C
002 C

5SY5 440-7
5SY5 450-7
5SY5 463-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.660
0.660
0.660

For application examples, see engineering manual at:


www.siemens.com/lowvoltage/manuals.
1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/17

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY7, 15 000 A

Selection and ordering data


Characteristic B

15 000
In

Mounting width

MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs 15000 A
1P, 230/400 V AC
6
10
13

A
A
C

5SY7 106-6
5SY7 110-6
5SY7 113-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.161
0.160
0.159

16
20
25

}
B
B

5SY7 116-6
5SY7 120-6
5SY7 125-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.159
0.161
0.162

32
40
50
63

B
C
C
C

5SY7 132-6
5SY7 140-6
5SY7 150-6
5SY7 163-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

002
002
002
002

0.164
0.212
0.168
0.176

C
C
C

5SY7 506-6
5SY7 510-6
5SY7 513-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.314
0.294
0.330

16
20
25

C
C
C

5SY7 516-6
5SY7 520-6
5SY7 525-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.311
0.314
0.321

32
40
50
63

C
C
C
C

5SY7 532-6
5SY7 540-6
5SY7 550-6
5SY7 563-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

002
002
002
002

0.321
0.336
0.330
0.330

B
B
C

5SY7 206-6
5SY7 210-6
5SY7 213-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.312
0.313
0.296

16
20
25

B
B
B

5SY7 216-6
5SY7 220-6
5SY7 225-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.302
0.313
0.316

32
40
50
63

C
C
C
C

5SY7 232-6
5SY7 240-6
5SY7 250-6
5SY7 263-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

002
002
002
002

0.325
0.324
0.321
0.336

B
B
C

5SY7 306-6
5SY7 310-6
5SY7 313-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.468
0.466
0.449

16
20
25

}
B
B

5SY7 316-6
5SY7 320-6
5SY7 325-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.462
0.465
0.472

32
40
50
63

B
B
B
C

5SY7 332-6
5SY7 340-6
5SY7 350-6
5SY7 363-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

002
002
002
002

0.488
0.481
0.490
0.485

C
C
C

5SY7 606-6
5SY7 610-6
5SY7 613-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.614
0.617
0.622

16
20
25

C
C
C

5SY7 616-6
5SY7 620-6
5SY7 625-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.606
0.622
0.634

32
40
50
63

C
C
C
C

5SY7 632-6
5SY7 640-6
5SY7 650-6
5SY7 663-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

002
002
002
002

0.638
0.635
0.649
0.665

C
B
C

5SY7 406-6
5SY7 410-6
5SY7 413-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.621
0.614
0.633

16
20
25

B
B
C

5SY7 416-6
5SY7 420-6
5SY7 425-6

1
1
1

1 unit
1 unit
1 unit

002
002
002

0.617
0.587
0.629

32
40
50
63

C
C
C
C

5SY7 432-6
5SY7 440-6
5SY7 450-6
5SY7 463-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

002
002
002
002

0.615
0.611
0.647
0.666

1P+N, 230 V AC
6
10
13

2P, 400 V AC
6
10
13

3P, 400 V AC
6
10
13

3P+N, 400 V AC
6
10
13

4P, 400 V AC
6
10
13

1)

1 MW (modular width) = 18 mm.


* You can order this quantity or a multiple thereof.

3/18

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY7, 15 000 A
Characteristic C

15 000
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

MCBs 15000 A
1P, 230/400 V AC
0.3
0.5
1

B
B
A

5SY7 114-7
5SY7 105-7
5SY7 101-7

003 C
003 C
003 C

5SY7 114-8
5SY7 105-8
5SY7 101-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.160
0.153
0.180

1.6
2
3

B
}
A

5SY7 115-7
5SY7 102-7
5SY7 103-7

003 C
003 C
003 C

5SY7 115-8
5SY7 102-8
5SY7 103-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.165
0.162
0.161

4
6
8

}
}
B

5SY7 104-7
5SY7 106-7
5SY7 108-7

003 B
003 B
003 C

5SY7 104-8
5SY7 106-8
5SY7 108-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.158
0.160
0.154

10
13
16

}
B
}

5SY7 110-7
5SY7 113-7
5SY7 116-7

003 B
003 C
003 B

5SY7 110-8
5SY7 113-8
5SY7 116-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.156
0.156
0.156

20
25
32

}
B
B

5SY7 120-7
5SY7 125-7
5SY7 132-7

003 C
003 C
003 C

5SY7 120-8
5SY7 125-8
5SY7 132-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.141
0.162
0.166

40
50
63

B
C
B

5SY7 140-7
5SY7 150-7
5SY7 163-7

003 C
003 C
003 C

5SY7 140-8
5SY7 150-8
5SY7 163-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.166
0.167
0.165

C
C
B

5SY7 514-7
5SY7 505-7
5SY7 501-7

003 C
003 C
003 C

5SY7 514-8
5SY7 505-8
5SY7 501-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.323
0.312
0.320

1.6
2
3

C
B
B

5SY7 515-7
5SY7 502-7
5SY7 503-7

003 C
003 C
003 C

5SY7 515-8
5SY7 502-8
5SY7 503-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.319
0.319
0.298

4
6
8

B
A
C

5SY7 504-7
5SY7 506-7
5SY7 508-7

003 B
003 C
003 C

5SY7 504-8
5SY7 506-8
5SY7 508-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.310
0.326
0.286

10
13
16

}
B
}

5SY7 510-7
5SY7 513-7
5SY7 516-7

003 C
003 C
003 B

5SY7 510-8
5SY7 513-8
5SY7 516-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.305
0.304
0.293

20
25
32

B
B
B

5SY7 520-7
5SY7 525-7
5SY7 532-7

003 C
003 C
003 C

5SY7 520-8
5SY7 525-8
5SY7 532-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.317
0.313
0.325

40
50
63

C
C
C

5SY7 540-7
5SY7 550-7
5SY7 563-7

003 C
003 C
003 C

5SY7 540-8
5SY7 550-8
5SY7 563-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.308
0.330
0.308

C
B
}

5SY7 214-7
5SY7 205-7
5SY7 201-7

003 C
003 C
003 B

5SY7 214-8
5SY7 205-8
5SY7 201-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.322
0.325
0.313

1.6
2
3

C
}
A

5SY7 215-7
5SY7 202-7
5SY7 203-7

003 C
003 A
003 B

5SY7 215-8
5SY7 202-8
5SY7 203-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.359
0.318
0.314

4
6
8

}
}
B

5SY7 204-7
5SY7 206-7
5SY7 208-7

003 A
003 A
003 B

5SY7 204-8
5SY7 206-8
5SY7 208-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.310
0.312
0.302

10
13
16

}
B
}

5SY7 210-7
5SY7 213-7
5SY7 216-7

003 A
003 C
003 }

5SY7 210-8
5SY7 213-8
5SY7 216-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.306
0.287
0.304

20
25
32

}
}
}

5SY7 220-7
5SY7 225-7
5SY7 232-7

003 B
003 B
003 C

5SY7 220-8
5SY7 225-8
5SY7 232-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.314
0.313
0.328

40
50
63

A
B
B

5SY7 240-7
5SY7 250-7
5SY7 263-7

003 C
003 C
003 C

5SY7 240-8
5SY7 250-8
5SY7 263-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.325
0.308
0.326

1P+N, 230 V AC
0.3
0.5
1

2P, 400 V AC
0.3
0.5
1

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/19

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY7, 15 000 A

Characteristic C

15 000
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

MCBs 15000 A
3P, 400 V AC
0.3
0.5
1

C
C
C

5SY7 314-7
5SY7 305-7
5SY7 301-7

003 C
003 C
003 C

5SY7 314-8
5SY7 305-8
5SY7 301-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.473
0.495
0.458

1.6
2
3

C
B
A

5SY7 315-7
5SY7 302-7
5SY7 303-7

003 C
003 C
003 C

5SY7 315-8
5SY7 302-8
5SY7 303-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.495
0.451
0.458

4
6
8

A
A
C

5SY7 304-7
5SY7 306-7
5SY7 308-7

003 C
003 C
003 B

5SY7 304-8
5SY7 306-8
5SY7 308-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.441
0.457
0.442

10
13
16

}
B
}

5SY7 310-7
5SY7 313-7
5SY7 316-7

003 B
003 C
003 A

5SY7 310-8
5SY7 313-8
5SY7 316-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.453
0.445
0.445

20
25
32

}
A
}

5SY7 320-7
5SY7 325-7
5SY7 332-7

003 B
003 A
003 B

5SY7 320-8
5SY7 325-8
5SY7 332-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.463
0.464
0.482

40
50
63

}
A
}

5SY7 340-7
5SY7 350-7
5SY7 363-7

003 B
003 B
003 B

5SY7 340-8
5SY7 350-8
5SY7 363-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.484
0.480
0.479

C
C
C

5SY7 614-7
5SY7 605-7
5SY7 601-7

003 C
003 C
003 C

5SY7 614-8
5SY7 605-8
5SY7 601-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.660
0.660

1.6
2
3

C
C
C

5SY7 615-7
5SY7 602-7
5SY7 603-7

003 C
003 C
003 C

5SY7 615-8
5SY7 602-8
5SY7 603-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.632
0.660

4
6
8

C
C
C

5SY7 604-7
5SY7 606-7
5SY7 608-7

003 C
003 C
003 C

5SY7 604-8
5SY7 606-8
5SY7 608-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.590
0.600

10
13
16

B
C
A

5SY7 610-7
5SY7 613-7
5SY7 616-7

003 C
003 C
003 C

5SY7 610-8
5SY7 613-8
5SY7 616-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.593
0.610
0.585

20
25
32

B
B
B

5SY7 620-7
5SY7 625-7
5SY7 632-7

003 C
003 C
003 C

5SY7 620-8
5SY7 625-8
5SY7 632-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.618
0.628
0.644

40
50
63

B
B
B

5SY7 640-7
5SY7 650-7
5SY7 663-7

003 C
003 C
003 C

5SY7 640-8
5SY7 650-8
5SY7 663-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.645
0.678
0.643

C
C
C

5SY7 414-7
5SY7 405-7
5SY7 401-7

003 C
003 C
003 C

5SY7 414-8
5SY7 405-8
5SY7 401-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.642
0.660
0.660

1.6
2
3

C
C
C

5SY7 415-7
5SY7 402-7
5SY7 403-7

003 C
003 C
003 C

5SY7 415-8
5SY7 402-8
5SY7 403-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.630
0.660

4
6
8

B
B
C

5SY7 404-7
5SY7 406-7
5SY7 408-7

003 C
003 C
003 C

5SY7 404-8
5SY7 406-8
5SY7 408-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.624
0.615
0.603

10
13
16

}
C
}

5SY7 410-7
5SY7 413-7
5SY7 416-7

003 B
003 C
003 B

5SY7 410-8
5SY7 413-8
5SY7 416-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.608
0.608
0.592

20
25
32

}
}
}

5SY7 420-7
5SY7 425-7
5SY7 432-7

003 B
003 B
003 B

5SY7 420-8
5SY7 425-8
5SY7 432-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.615
0.628
0.639

40
50
63

}
}
}

5SY7 440-7
5SY7 450-7
5SY7 463-7

003 B
003 B
003 B

5SY7 440-8
5SY7 450-8
5SY7 463-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.642
0.603
0.642

3P+N, 400 V AC
0.3
0.5
1

4P, 400 V AC
0.3
0.5
1

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/20

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY8, 25 kA

Selection and ordering data


Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

MCBs 25 kA
1P, 230/400 V AC
0.3
0.5
1

C
C
B

5SY8 114-7
5SY8 105-7
5SY8 101-7

003 C
003 C
003 C

5SY8 114-8
5SY8 105-8
5SY8 101-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.167
0.165
0.152

1.6
2
3

C
}
C

5SY8 115-7
5SY8 102-7
5SY8 103-7

003 C
003 B
003 C

5SY8 115-8
5SY8 102-8
5SY8 103-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.165
0.163
0.161

4
6
8

B
}
C

5SY8 104-7
5SY8 106-7
5SY8 108-7

003 C
003 C
003 C

5SY8 104-8
5SY8 106-8
5SY8 108-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.158
0.159
0.156

10
13
16

A
C
}

5SY8 110-7
5SY8 113-7
5SY8 116-7

003 C
003 C
003 C

5SY8 110-8
5SY8 113-8
5SY8 116-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.157
0.142
0.155

20
25
32

A
C
B

5SY8 120-7
5SY8 125-7
5SY8 132-7

003 B
003 C
003 C

5SY8 120-8
5SY8 125-8
5SY8 132-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.165
0.162
0.166

40
50
63

C
C
C

5SY8 140-7
5SY8 150-7
5SY8 163-7

003 C
003 C
003 C

5SY8 140-8
5SY8 150-8
5SY8 163-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.155
0.158
0.160

C
C
C

5SY8 514-7
5SY8 505-7
5SY8 501-7

003 C
003 C
003 C

5SY8 514-8
5SY8 505-8
5SY8 501-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.330
0.323
0.337

1.6
2
3

C
C
C

5SY8 515-7
5SY8 502-7
5SY8 503-7

003 C
003 C
003 C

5SY8 515-8
5SY8 502-8
5SY8 503-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.324
0.318
0.318

4
6
8

C
B
C

5SY8 504-7
5SY8 506-7
5SY8 508-7

003 C
003 C
003 C

5SY8 504-8
5SY8 506-8
5SY8 508-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.311
0.326
0.313

10
13
16

B
C
B

5SY8 510-7
5SY8 513-7
5SY8 516-7

003 C
003 C
003 C

5SY8 510-8
5SY8 513-8
5SY8 516-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.282
0.305
0.297

20
25
32

C
C
C

5SY8 520-7
5SY8 525-7
5SY8 532-7

003 C
003 C
003 C

5SY8 520-8
5SY8 525-8
5SY8 532-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.318
0.312
0.366

40
50
63

C
C
C

5SY8 540-7
5SY8 550-7
5SY8 563-7

003 B
003 B
003 B

5SY8 540-8
5SY8 550-8
5SY8 563-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.325
0.326
0.330

C
C
B

5SY8 214-7
5SY8 205-7
5SY8 201-7

003 C
003 C
003 C

5SY8 214-8
5SY8 205-8
5SY8 201-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.337
0.325
0.313

1.6
2
3

C
B
C

5SY8 215-7
5SY8 202-7
5SY8 203-7

003 C
003 B
003 C

5SY8 215-8
5SY8 202-8
5SY8 203-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.316
0.322
0.346

4
6
8

A
A
C

5SY8 204-7
5SY8 206-7
5SY8 208-7

003 C
003 A
003 C

5SY8 204-8
5SY8 206-8
5SY8 208-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.314
0.311
0.306

10
13
16

}
C
}

5SY8 210-7
5SY8 213-7
5SY8 216-7

003 B
003 C
003 C

5SY8 210-8
5SY8 213-8
5SY8 216-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.305
0.305
0.304

20
25
32

B
B
B

5SY8 220-7
5SY8 225-7
5SY8 232-7

003 C
003 B
003 C

5SY8 220-8
5SY8 225-8
5SY8 232-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.305
0.318
0.324

40
50
63

C
C
C

5SY8 240-7
5SY8 250-7
5SY8 263-7

003 C
003 C
003 C

5SY8 240-8
5SY8 250-8
5SY8 263-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.308
0.331
0.327

1P+N, 230 V AC
0.3
0.5
1

2P, 400 V AC
0.3
0.5
1

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/21

Siemens AG 2011

Miniature Circuit Breakers


5SY and 5SP Miniature Circuit Breakers
5SY8, 25 kA

Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

MCBs 25 kA
3P, 400 V AC
0.3
0.5
1

1.6
2
3

C
C
A
C
C
C
C

4
6
8

B
C
B

10
13
16

C
}
C

20
25
32

}
A
B

40
50
63

B
B

5SY8 314-7
5SY8 305-7
5SY8 301-7

003 C
003 C
003 C

5SY8 314-8
5SY8 305-8
5SY8 301-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.495
0.482
0.478

5SY8 315-7
5SY8 302-7
5SY8 303-7

003 C
003 C
003 C

5SY8 315-8
5SY8 302-8
5SY8 303-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.495
0.471
0.467

5SY8 304-7
5SY8 306-7
5SY8 308-7

003 C
003 C
003 C

5SY8 304-8
5SY8 306-8
5SY8 308-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.460
0.442
0.495

5SY8 310-7
5SY8 313-7
5SY8 316-7

003 C
003 C
003 C

5SY8 310-8
5SY8 313-8
5SY8 316-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.455
0.487
0.449

5SY8 320-7
5SY8 325-7
5SY8 332-7

003 C
003 B
003 B

5SY8 320-8
5SY8 325-8
5SY8 332-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.452
0.472
0.482

5SY8 340-7
5SY8 350-7
5SY8 363-7

003 C
003 B
003 C

5SY8 340-8
5SY8 350-8
5SY8 363-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.464
0.465
0.467

5SY8 614-7
5SY8 605-7
5SY8 601-7

003 C
003 C
003 C

5SY8 614-8
5SY8 605-8
5SY8 601-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.660
0.660

5SY8 615-7
5SY8 602-7
5SY8 603-7

003 C
003 C
003 C

5SY8 615-8
5SY8 602-8
5SY8 603-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.631
0.621

5SY8 604-7
5SY8 606-7
5SY8 608-7

003 C
003 C
003 C

5SY8 604-8
5SY8 606-8
5SY8 608-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.660
0.660

5SY8 610-7
5SY8 613-7
5SY8 616-7

003 C
003 C
003 C

5SY8 610-8
5SY8 613-8
5SY8 616-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.571
0.609
0.602

5SY8 620-7
5SY8 625-7
5SY8 632-7

003 C
003 C
003 C

5SY8 620-8
5SY8 625-8
5SY8 632-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.596
0.601
0.611

5SY8 640-7
5SY8 650-7
5SY8 663-7

003 C
003 C
003 C

5SY8 640-8
5SY8 650-8
5SY8 663-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.617
0.650
0.625

5SY8 414-7
5SY8 405-7
5SY8 401-7

003 C
003 C
003 C

5SY8 414-8
5SY8 405-8
5SY8 401-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.660
0.636

5SY8 415-7
5SY8 402-7
5SY8 403-7

003 C
003 C
003 C

5SY8 415-8
5SY8 402-8
5SY8 403-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.681
0.660

5SY8 404-7
5SY8 406-7
5SY8 408-7

003 C
003 C
003 C

5SY8 404-8
5SY8 406-8
5SY8 408-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.660
0.660
0.598

5SY8 410-7
5SY8 413-7
5SY8 416-7

003 C
003 C
003 C

5SY8 410-8
5SY8 413-8
5SY8 416-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.597
0.660
0.601

5SY8 420-7
5SY8 425-7
5SY8 432-7

003 C
003 C
003 C

5SY8 420-8
5SY8 425-8
5SY8 432-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.627
0.627
0.641

5SY8 440-7
5SY8 450-7
5SY8 463-7

003 C
003 C
003 C

5SY8 440-8
5SY8 450-8
5SY8 463-8

1
1
1

1 unit
1 unit
1 unit

004
004
004

0.647
0.646
0.644

3P+N, 400 V AC
0.3
0.5
1

1.6
2
3

C
C
C
C
C
C
C

4
6
8

C
C
C

10
13
16

C
B
C

20
25
32

C
B
C

40
50
63

C
A

4P, 400 V AC
0.3
0.5
1

1.6
2
3
4
6
8
10
13
16
20
25
32
40
50
63
1)

C
C
C
C
C
C
C
C
C
B
C
}
A
}
}
}
}
}

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/22

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SJ6 ...-.KS miniature circuit breakers
with plug-in terminals

Overview

Miniature circuit breakers with plug-in terminals are used for the
protection of socket outlets and lighting circuits with the most
common rated currents of 10 to 20 A.

Benefits

Double, self-contained, screwless outgoing terminals for fast


connection of conductors.

The plug-in terminal, offering easily accessible and angled cable entries for manual insertion, saves mounting time
Removal of individual conductors requires no tools and ensures high operating safety
No end sleeves required for finely stranded conductors. This
saves mounting time.

Conventional pin busbars are used for the incoming terminal.


This ensures clear, manageable and convenient access to all
terminals as part of the uniform Siemens connection concept.

Siemens LV 10.1 2011

3/23

Siemens AG 2011

Miniature Circuit Breakers


5SJ6 ...-.KS miniature circuit breakers
with plug-in terminals

Technical specifications
5SJ6 . . .-.KS
EN 60898-1

Standards

See annex, chapter 20

Approvals
Operational voltage

V AC

230/400

Min.

V AC/DC

24

Max.
Max.

V AC
V DC/pole

250/440
601)

kA AC

V AC

250/440
2/III

Rated switching capacity

Acc. to EN 60898-1

Insulation coordination
Rated insulation voltage
Pollution degree for overvoltage category
Touch protection

Acc. to EN 50274

Yes

Handle end position, sealable


Degree of protection

Yes
Acc. to EN 60529

IP20, with connected conductors

CFC and silicone-free

Yes

Terminals

Screwless terminals on the outgoing terminals for 1.5 ... 4 mm2

Conductor cross-sections
Top, plug-in terminals

- Solid, stranded and finely stranded, without end sleeve


- Finely stranded, with end sleeve
Bottom, tunnel terminal

- Solid, stranded or finely stranded, with end sleeve

mm2
mm2

1.5 ... 4
1.5 ... 2.5

mm2

0.75 ... 25
Any

Mounting position
Service life,
on average, with rated load

20000 actuations
C

Ambient temperature
Resistance to climate

Acc. to IEC 60068-2-30

Resistance to vibrations

Acc. to IEC 60068-2-6

1)

6 cycles
m/s2

The operational voltage 60 V DC/pole takes into account a battery charging voltage with a peak value of 72 V.

3/24

Siemens LV 10.1 2011

-25 ... +45, occasionally +55, max. 95 % humidity,


storage temperature: -40 ... +75
50 at 25 ... 150 Hz and 60 at 35 Hz (4 sec)

Siemens AG 2011

Miniature Circuit Breakers


5SJ6 ...-.KS miniature circuit breakers
with plug-in terminals

Selection and ordering data


6 000
3

Characteristic B
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic C
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Miniature circuit
breakers
with plug-in terminal
1P
10
13
16

20

B
B
A

5SJ6 110-6KS
5SJ6 113-6KS
5SJ6 116-6KS

002 B
002 B
002 B

5SJ6 110-7KS
5SJ6 113-7KS
5SJ6 116-7KS

1
1 unit
1 1/12 units
1
1 unit

003
003
003

0.117
0.098
0.123

5SJ6 120-6KS

002 B

5SJ6 120-7KS

1 1/12 units

003

0.103

B
B
B

5SJ6 510-6KS
5SJ6 513-6KS
5SJ6 516-6KS

002 B
002 B
002 B

5SJ6 510-7KS
5SJ6 513-7KS
5SJ6 516-7KS

1
1
1

1/6 units
1/6 units
1/6 units

003
003
003

0.209
0.210
0.208

5SJ6 520-6KS

002 B

5SJ6 520-7KS

1/6 units

003

0.209

B
B
B

5SJ6 210-6KS
5SJ6 213-6KS
5SJ6 216-6KS

002 B
002 B
002 B

5SJ6 210-7KS
5SJ6 213-7KS
5SJ6 216-7KS

1
1
1

1/6 units
1/6 units
1/6 units

003
003
003

0.229
0.228
0.226

5SJ6 220-6KS

002 B

5SJ6 220-7KS

1/6 units

003

0.226

B
B
B

5SJ6 310-6KS
5SJ6 313-6KS
5SJ6 316-6KS

002 B
002 B
002 B

5SJ6 310-7KS
5SJ6 313-7KS
5SJ6 316-7KS

1
1
1

1/4 units
1/4 units
1/4 units

003
003
003

0.353
0.357
0.358

5SJ6 320-6KS

002 B

5SJ6 320-7KS

1/4 units

003

0.354

1P+N
10
13
16

20

2P
10
13
16

20

3P
10
13
16

20

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/25

Siemens AG 2011

Miniature Circuit Breakers


5SY6 0 miniature circuit breakers
1+N in 1 MW

Overview
These miniature circuit breakers are used for the protection of
plants with switched neutral conductors in distribution boards
with little space. They are just a single modular width.

The devices are approved for worldwide use according to IEC


standards for systems up to 250 V AC. 60 V DC per pole is permitted in DC systems according to IEC standards.

Compact busbars facilitate installation in space saving distribution boards.

Benefits

Auxiliary switches and fault signal contacts from the highcapacity range can be freely mounted on these miniature
circuit breakers. This increases availability and cuts down on
logistics.

For 3-pole busbars, the 5ST3 6 busbar system is used


a universal system suitable for all miniature circuit breakers.

By actuating the latching slide, the miniature circuit breakers


can be quickly and easily removed from the assembly.

The infeed can be implemented either from the top or the


bottom. Additional terminals with lateral cable entry facilitate
mounting when using large conductor cross-sections.

3/26

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SY6 0 miniature circuit breakers
1+N in 1 MW

Technical specifications

5SY6 0..
EN 60898-1

Standards

See annex, chapter 20

Approvals
V AC

230

Min.

V AC/DC

24

Max.
Max.

V AC
V DC/pole

250
601)

Rated switching capacity Icn

kA AC

Insulation coordination
Rated insulation voltage
Pollution degree for overvoltage category

V AC

250
2/III

Rated voltage Un
Operational voltage

Touch protection

Acc. to EN 50274

Yes

Handle end position, sealable

Yes

Degree of protection

IP20, with connected conductors

CFC and silicone-free

Yes

Terminals
Solid and stranded,
top and bottom terminal
Finely stranded, with end sleeve,
top and bottom terminal
Terminal tightening torque

mm2

0.75 ... 16

mm2

0.75 ... 10

Nm

2.0 ... 2.5


Any

Mounting position
Service life
On average, with rated load

20000 actuations
at 2 A/4 A and 40 A: 8000 actuations
C

Ambient temperature
Resistance to climate

Acc. to IEC 60068-2-30

Resistance to vibrations

Acc. to IEC 60068-2-6

1)

-25 ... +45, occasionally +55, max. 95 % humidity,


storage temperature: -40 ... +75
6 cycles

m/s2

50 at 25 ... 150 Hz and 60 at 35 Hz (4 sec)

The operational voltage 60 V DC/pole takes into account a battery charging voltage with a peak value of 72 V.

Siemens LV 10.1 2011

3/27

Siemens AG 2011

Miniature Circuit Breakers


5SY6 0 miniature circuit breakers
1+N in 1 MW

Selection and ordering data


6 000
3

Characteristic B
In

Mount- DT
ing
width

MW1)

Characteristic C

Order No.

Price
per PU

PG DT

Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Miniature circuit breakers, compact, 1+N (1P+N), 230 V AC


N pole, right
2
4
6

D
D
002 A

5SY6 002-7
5SY6 004-7
5SY6 006-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.107
0.106
0.100

--5SY6 006-6

8
10
13

A
A

-5SY6 010-6
5SY6 013-6

D
002 A
002 A

5SY6 008-7
5SY6 010-7
5SY6 013-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.107
0.100
0.107

16
20
25

A
A
A

5SY6 016-6
5SY6 020-6
5SY6 025-6

002 A
002 A
002 A

5SY6 016-7
5SY6 020-7
5SY6 025-7

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.100
0.100
0.100

32
40

A
D

5SY6 032-6
5SY6 040-6

002 A
002 D

5SY6 032-7
5SY6 040-7

1
1

1 unit
1 unit

003
003

0.111
0.100

D
D
002 D

5SY6 002-7KL
5SY6 004-7KL
5SY6 006-7KL

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.106
0.100
0.100

N pole, left
2
4
6

1
D

--5SY6 006-6KL

8
10
13

D
D

-5SY6 010-6KL
5SY6 013-6KL

D
002 A
002 D

5SY6 008-7KL
5SY6 010-7KL
5SY6 013-7KL

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.107
0.100
0.107

16
20
25

A
D
D

5SY6 016-6KL
5SY6 020-6KL
5SY6 025-6KL

002 D
002 D
002 D

5SY6 016-7KL
5SY6 020-7KL
5SY6 025-7KL

1
1
1

1 unit
1 unit
1 unit

003
003
003

0.100
0.100
0.100

32
40

D
D

5SY6 032-6KL
5SY6 040-6KL

002 D
002 D

5SY6 032-7KL
5SY6 040-7KL

1
1

1 unit
1 unit

003
003

0.112
0.100

PG

Weight
per PU
approx.

Pin
Length
spacing
MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

mm

kg

5ST3 7 busbar systems, 10 mm2, 12 MW,


for MCBs 1+N in 1 MW of the compact range,
can be cut, with end caps

Single-phase
For 12 MCBs 1+N, gray
For 12 MCBs 1+N, blue

216
216

A
A

5ST3 762
5ST3 763

1
1

10 units
10 units

027
027

0.022
0.001

1016
1016

A
A

5ST3 764
5ST3 765

1
1

10 units
10 units

027
027

0.134
0.134

A
A

5ST3 766
5ST3 767

1
1

10 set
10 set

027
027

0.001
0.001

A
A
}

5ST3 613
5ST3 614
5ST3 615

1
1
1

10 units
10 units
10 units

027
027
027

0.030
0.056
0.075

5ST3 768

25 units

027

0.018

5ST3 7 busbar systems, 10 mm2,


for MCBs 1+N in 1 MW of the compact range,
can be cut, without end caps

Single-phase
For MCBs 1+N, gray
For MCBs 1+N, blue

End caps for 5ST3 76 busbars


1 set comprises a right and a left cap
Gray
Blue
5ST3 6 busbar systems, 10 mm2,
for MCBs, fixed lengths,
cannot be cut, fully insulated
Three-phase
For 6 MCBs 1+N
For 9 MCBs 1+N
For 12 MCBs 1+N

102
157.5
210

Terminals for 5ST3 76


Side terminal version
For conductors up to 25 mm2
1)

1 MW (modular width) = 18 mm.


* You can order this quantity or a multiple thereof.

3/28

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Additional components

Overview
The Siemens mounting concept supports the combination of all
5ST3 additional components with Siemens 5SY and 5SP miniature circuit breakers and with 5SU1 RCBOs.
5SL and 5SY6 0. . miniature circuit breakers are suitable for
mounting auxiliary switches and fault signal contacts. Auxiliary
switches can also be mounted on 5TE8 flush-mounting circuit
breakers and 5SG7 1 MINIZED switch disconnectors.
Auxiliary switches (AS)
The auxiliary switch (AS) always signals the contact position of
the miniature circuit breaker, regardless of whether the miniature
circuit breaker was tripped manually or as the result of a fault. An
additional version is also available for the switching of small currents and voltages for the control of programmable control systems (PLCs) acc. to EN 61131-2. The auxiliary switch with test
button enables the testing of control circuits without the need to
switch the miniature circuit breaker.
Fault signal contacts (FC)
The fault signal contact (FC) signals the automatic tripping of the
miniature circuit breaker in the event of a fault, such as an overload or a short circuit. If the fault signal contact is activated, the
contact position does not change if the miniature circuit breaker
is tripped manually. Fault signal contacts with TEST and RESET
buttons enable the testing of control circuits without the need to
trip the miniature circuit breaker. The red RESET button integrated in the handle also indicates the automatic tripping of the
MCB. The signal can be acknowledged manually using the
RESET button.

Shunt trips (ST)


Shunt trips are used for the remote tripping of miniature circuit
breakers.
Undervoltage releases (UR)
Undervoltage releases are integrated (e.g. in EMERGENCY
STOP loops), thus ensuring that the MCB trips in the event of an
emergency, which, in turn, ensures disconnection of the control
circuit according to EN 60204. In the event that the voltage is interrupted or too low, it also trips, i.e. prevents activation of the
MCB.
Remote controlled mechanisms (RC)
Remote controlled mechanisms are used for the remote ON/OFF
switching of miniature circuit breakers and the remote ON
switching of RC units, as well as the local manual switching of
these devices. A blocking function permits maintenance work. In
the event that a miniature circuit breaker or RC unit is tripped, an
acknowledgment must be carried out prior to switching back on.
The remote controlled mechanism has an operating mode selector switch with the functions: "Locked", "Manual" and "Remote
Switching". The mechanism can be mechanically latched and
locked, which serves to protect personnel during maintenance
work.
RC units
RC units can be combined with miniature circuit breakers of
characteristic A, B, C and D. They then form a combination of
RCCB and MCB for personnel, fire and line protection. The combinations can be tailored to meet individual requirements.
For information on RC units, please refer to the section "Residual
current protective devices".

Benefits
Can be universally retrofitted with all additional components

The 5SL, 5SY and 5SP miniature circuit breakers are ideal for
the quick and easy mounting of auxiliary switches and fault
signal contacts.
Captive metal brackets on additional components ensure the
quick and easy mounting of devices on the miniature circuit
breakers without the need for tools.

Fault signal contacts with TEST and RESET button enable the
simple testing of auxiliary circuits and, in the event of a fault,
acknowledgement of the fault over the RESET button, without
the need to switch the miniature circuit breakers.

Siemens LV 10.1 2011

3/29

Siemens AG 2011

Miniature Circuit Breakers


Additional components

The auxiliary switches with TEST button enable the simple manual testing of control circuits during operation of the entire plant
without the need to switch the miniature circuit breakers.

Technical specifications
Auxiliary switches (AS)
5ST3 010, 5ST3 010-2
5ST3 011, 5ST3 011-2
5ST3 012, 5ST3 012-2

Fault signal contacts (FC)


5ST3 013
5ST3 014
5ST3 015

5ST3 020, 5ST3 020-2


5ST3 021, 5ST3 021-2
5ST3 022, 5ST3 022-2

Standards

EN 62019; IEC/EN 60947-5-1; UL 1077; CSA C22.2 No. 235

Approvals

See annex, chapter 20

Short-circuit protection

Miniature circuit breaker or gG 6 A fuse

Contact load
Min.
Max.

50 mA, 24 V
--

1 mA/5 V DC
50 mA/30 V DC

50 mA, 24 V
--

400 V AC, AC-14, NO


230 V AC, AC-14, NO
400 V AC, AC-13, NC
230 V AC, AC-13, NC

A
A
A
A

2
6
2
6

-----

2
6
2
6

220 V DC, DC-13, NO+NC


110 V DC, DC-13, NO+NC
60 V DC, DC-13, NO+NC
24 V DC, DC-13, NO+NC

A
A
A
A

1
1
3
6

-----

1
1
3
6

20000 actuations

20000 actuations

20000 actuations

mm2
AWG

0.5 ... 2.5


22 ... 14

0.5 ... 2.5


22 ... 14

0.5 ... 2.5


22 ... 14

Nm
lb/in

0.5
4.5

0.5
4.5

0.5
4.5

Undervoltage releases
(UR)

Shunt trips (ST)

Remote controlled
mechanisms (RC)

5ST3 04.

5ST3 030

5ST3 031

5ST3 050

Service life, on average, with rated load


Conductor cross-sections
Terminals
Terminal tightening torque

EN 60947-1

Standards
V AC

230

110 ... 415

24 ... 60

230

V DC

24, 110

110

24 ... 60

--

Hz

--

50 ... 60

50 ... 60

Acc. to EN 60947-1, 7.2.1.3


- Releases
- Permissible fluctuations of the power supply

< 0.35 ... 0.7 Un


0.85 ... 1.1 Un

---

---

Acc. to EN 60947-1, 7.2.1.4

--

0.7 ... 1.1 Un

--

Short-circuit protection

Miniature circuit breaker or gG 6 A fuse

Minimum contact load

50 mA, 24 V

50 mA, 24 V

--

Tripping operations

max. 2000

max. 2000

--

Service life, on average, with rated load

20000 actuations

20000 actuations

20000 actuations

mm2
AWG

0.5 ... 2.5


22 ... 14

0.5 ... 2.5


22 ... 14

0.5 ... 2.5


22 ... 14

Nm
lb/in

0.8
6.8

0.8
6.8

0.5
4.5

Rated voltages Un
Rated frequency fn
Response limits

Conductor cross-sections
Terminals
Terminal tightening torque

For technical data on the RC units, please refer to the chapter, "Residual current protective devices".

3/30

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Additional components

Selection and ordering data


Rated voltage

Mount- DT
ing
width

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.

Un
V

MW1)

kg

Auxiliary switches (AS)


For 5SL, 5SY, 5SP miniature circuit breakers,
5SU1 RCBOs and 5TE8 switches
}
}

5ST3 010
5ST3 013

1
1

1 unit
1 unit

027
027

0.066
0.055

2 NO
For small output

A
B

5ST3 011
5ST3 014

1
1

1 unit
1 unit

027
027

0.055
0.054

2 NC
For small output

A
B

5ST3 012
5ST3 015

1
1

1 unit
1 unit

027
027

0.055
0.060

1 NO + 1 NC
For small output

0.5

Auxiliary switches (AS) with TEST button


For 5SL, 5SY, 5SP miniature circuit breakers,
5SU1 RCBOs and 5TE8 switches
1 NO + 1 NC

5ST3 010-2

1 unit

027

0.045

2 NO

0.5

5ST3 011-2

1 unit

027

0.045

2 NC

5ST3 012-2

1 unit

027

0.045

0.5

}
B
A

5ST3 020
5ST3 021
5ST3 022

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.056
0.056
0.057

0.5

A
A
A

5ST3 020-2
5ST3 021-2
5ST3 022-2

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.050
0.050
0.050

}
C
C

5ST3 040
5ST3 041
5ST3 042

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.107
0.105
0.101

}
C
}

5ST3 043
5ST3 044
5ST3 045

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.092
0.091
0.088

1
1

}
}

5ST3 030
5ST3 031

1
1

1 unit
1 unit

027
027

0.090
0.090

3.5

5ST3 050

1 unit

027

0.461

Fault signal contacts (FC)


For 5SL, 5SY, 5SP miniature circuit breakers and
5SU1 RCBOs
1 NO + 1 NC
2 NO
2 NC

Fault signal contacts (FC) with TEST and


ACKNOWLEDGE button
For 5SL, 5SY, 5SP miniature circuit breakers
and 5SU1 RCBOs
1 NO + 1 NC
2 NO
2 NC
Undervoltage releases (UR)
For 5SY, 5SP MCBs and 5SU1 RCBOs
but not suitable for use with 5SY6 0.. and 5SL MCBs
With integrated auxiliary switch
230 AC
110 DC
24 DC
Without integrated auxiliary switch
230 AC
110 DC
24 DC
Shunt trips (ST)
For 5SY, 5SP MCBs and 5SU1 RCBOs
but not suitable for use with 5SY6 0.. and 5SL MCBs
2 NO
2 NC

Remote controlled mechanisms (RC)


For 5SY, 5SP MCBs and 5SU1 RCBOs
but not suitable for use with 5SL MCB
230 AC

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/31

Siemens AG 2011

Miniature Circuit Breakers


Additional components

Rated residual Rated current


current

In

In

mA

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW1)

Weight
per PU
approx.

kg

RC units, type A, instantaneous tripping


For 5SY miniature circuit breakers,
not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
2P, 230 ... 400 V AC, 50 ... 60 Hz
10
30
300

0.3 ... 16
0.3 ... 40

30
100
300
500

0.3 ... 63

B
}
A

5SM2 121-6
5SM2 322-6
5SM2 622-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.207
0.209
0.199

A
B
B
B

5SM2 325-6
5SM2 425-6
5SM2 625-6
5SM2 725-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.215
0.211
0.203
0.198

A
A

5SM2 332-6
5SM2 632-6

1
1

1 unit
1 unit

007
007

0.314
0.295

B
B
B
B

5SM2 335-6
5SM2 435-6
5SM2 635-6
5SM2 735-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.359
0.327
0.298
0.322

}
}

5SM2 342-6
5SM2 642-6

1
1

1 unit
1 unit

007
007

0.337
0.326

A
B
A
A

5SM2 345-6
5SM2 445-6
5SM2 645-6
5SM2 745-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.397
0.357
0.328
0.326

3.5

B
B

5SM2 327-6
5SM2 627-6

1
1

1 unit
1 unit

007
007

0.529
0.458

B
A

5SM2 347-6
5SM2 647-6

1
1

1 unit
1 unit

007
007

0.934
0.682

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
3P, 230 ... 400 V AC, 50 ... 60 Hz
30
300

0.3 ... 40

30
100
300
500

0.3 ... 63

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
4P, 230 ... 400 V AC, 50 ... 60 Hz
30
300

0.3 ... 40

30
100
300
500

0.3 ... 63

For 5SP4 miniature circuit breakers


(characteristics B and C)
2P, 125 ... 230 V AC, 50 ... 60 Hz
30
300

80 ... 100

For 5SP4 miniature circuit breakers


(characteristics B and C)
4P, 230 ... 400 V AC, 50 ... 60 Hz
30
300

1)

80 ... 100

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/32

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Additional components
Rated residual Rated current
current
In

In

mA

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW1)

Weight
per PU
approx.
kg

RC units, type A, super resistant


For 5SY miniature circuit breakers,
not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
2P, 230 ... 400 V AC, 50 ... 60 Hz
30

0.3 ... 40

30

0.3 ... 63

5SM2 322-6KK01

1 unit

007

0.215

5SM2 325-6KK01

1 unit

007

0.214

5SM2 332-6KK01

1 unit

007

0.365

5SM2 335-6KK01

1 unit

007

0.365

5SM2 342-6KK01

1 unit

007

0.390

5SM2 345-6KK01

1 unit

007

0.388

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
3P, 230 ... 400 V AC, 50 ... 60 Hz
30

0.3 ... 40

30

0.3 ... 63

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
4P, 230 ... 400 V AC, 50 ... 60 Hz
30

0.3 ... 40

30

0.3 ... 63

RC units, type A, selective


For 5SY miniature circuit breakers,
not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
2P, 230 ... 400 V AC, 50 ... 60 Hz
300

0.3 ... 40

300

0.3 ... 63

5SM2 622-8

1 unit

007

0.210

5SM2 625-8

1 unit

007

0.210

B
B
D

5SM2 635-8
5SM2 735-8
5SM2 835-8

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.341
0.323
0.304

A
A
A

5SM2 645-8
5SM2 745-8
5SM2 845-8

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.373
0.333
0.333

3.5

5SM2 627-8

1 unit

007

0.519

A
A

5SM2 647-8
5SM2 847-8

1
1

1 unit
1 unit

007
007

0.838
0.706

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
3P, 230 ... 400 V AC, 50 ... 60 Hz
300
500
1000

0.3 ... 63

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8, 5SY6 0..
and 5SL,
4P, 230 ... 400 V AC, 50 ... 60 Hz
300
500
1000

0.3 ... 63

For 5SP4 miniature circuit breakers


(characteristics B and C)
2P, 125 ... 230 V AC, 50 ... 60 Hz
300

80 ... 100

For 5SP4 miniature circuit breakers


(characteristics B and C)
4P, 230 ... 400 V AC, 50 ... 60 Hz
300
1000

1)

80 ... 100

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/33

Siemens AG 2011

Miniature Circuit Breakers


Additional components

Version

Mount- DT
ing
width

Order No.

MW1)

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Terminal covers
For miniature circuit breakers, not suitable for
use with 5SY6 0. .,
For additional covering of the screw openings
per pole, sealable. In the case of 5SY, also
prevents removal of device from the standard
mounting rail.

5ST3 800

1 10 units

027

0.002

For 5SP and 5SY miniature circuit breakers


For padlock with max. 3 mm shackle

5ST3 801

1 unit

027

0.012

For 5SL miniature circuit breakers


For padlock with 3 ... 6 mm shackle

5ST3 806

5 units

027

0.007

5ST3 802

1 unit

027

0.031

5ST3 803

1 set

027

0.041

5ST3 807

1 set

027

0.034

0.5

5TG8 240

2 units

027

0.010

5ST2 201

1 unit

027

0.013

5ST2 173

1 set

027

0.049

Handle locking devices


Sealable to prevent unwanted mechanical
ON/OFF switching

Padlocks
For 5ST3 801 and 5ST3 806 handle locking devices

Locking devices
For 5SP and 5SY miniature circuit breakers
comprising 5ST3 801 handle locking device
and 5ST3 802 padlock
Locking devices
For 5SL miniature circuit breakers,
comprising 5ST3 806 handle locking device
and 5ST3 802 padlock
Spacers
Can be placed on either side of the standard
mounting rail. Two spacers allow for convenient cable routing

Fixing parts
Made of plastic, for use on a mounting plate

Inscription labels
15 mm x 9 mm, 3 frames 44 labels, can be
mounted on casing collar, white, self-adhesive

Labeling system
Inscription on self-adhesive labels for a uniform and tidy appearance in electrical power distribution.
The labeling program can be downloaded to your PC free of charge at:
www.siemens.com/labeling-tool
Recommended ELAT-3-747 labels for printing out on
normal printers can be ordered at:

Brady GmbH
Otto-Hahn-Str. 5-7
D-63222 Langen
Tel: +49 (0) 61 03/75 98-660
* You can order this quantity or a multiple thereof.

3/34

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Additional components
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Terminal covers, gray


For surface mounting, degree of protection IP40,
sealable, with 35 mm standard mounting rail
Up to 2.5 MW
Up to 4.5 MW

B
B

5SW3 004
5SW3 005

1
1

1 unit
1 unit

008
008

0.091
0.171

B
B

5SW3 006
5SW3 007

1
1

1/4 units
1 unit

008
008

0.133
0.162

5SW1 200

1 unit

008

0.447

End plates (for snapping onto standard mounting


rail)

5ST2 134

10 units

027

0.021

Angled profile (approx. 1 m long)

5ST2 135

5 units

027

0.288

Alternative flat profiles


(as a cover between the rows of devices length
approx. 1 m)

5ST2 136

5 units

027

0.239

7LF9 006

1 unit

027

0.070

Wall enclosures, gray


For flush mounting, degree of protection IP40
with 35 mm standard mounting rail
Up to 2.5 MW
Up to 4.5 MW

Molded-plastic enclosures, gray


For surface mounting, degree of protection IP54,
with 35 mm standard mounting rail, sealable
with transparent hinged lid
For 4.5 MW

Covers
Can be assembled as mini distribution board,
suitable for all devices, cover parts prepared for rail
mounting of conventional label caps, comprising:

Holders for front panel installation


Universal application for devices from 1 to 6 MW
Cutout dimensions:
Height 45+0.5 mm
Width: 23, 41, 59, 77, 95 or 113 mm

Intermediate frames for 70 mm devices in 55 mm


ALPHA SIMBOX distribution boards
Versions

8GB4 563

1-series

8GB4 561

1 unit

032

0.900

2-series

8GB4 562

1 unit

032

1.100

3-series

8GB4 563

1 unit

032

1.300

4-series

8GB4 564

1 unit

032

1.500

For further information on the ALPHA distribution boards, ALPHA SIMBOX small distribution boards and intermediate frames,
please refer to Catalog LV 10.2, chapter, "Distribution boards".

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/35

Siemens AG 2011

Miniature Circuit Breakers


Additional components

More information
The Siemens mounting concept supports the combination of all
5ST3 additional components with miniature circuit breakers of
the 5SY and 5SP series and RCBOs of the 5SU1 series.

The chart shows which additional components can be mounted


on either the right or the left.

5SL and 5SY6 0.. miniature circuit breakers are suitable for
mounting auxiliary switches and fault signal contacts. Auxiliary
switches can also be mounted on 5TE8 flush-mounting circuit
breakers and 5SG7 1 MINIZED switch disconnectors.
5SM2

5SY / 5SP4

5ST3

or

or

or

I2_18123a

RC-Unit

MCB

RC

AS

FC

AS
FC

AS
FC

AS
FC

FC
AS

AS
FC

FC
AS

AS
FC

FC
AS

5SU1

or

RCBO

RC-Unit:
MCB:
RCBO:
RC:
UR:
ST:
AS:
FC:

RC

Residual current unit


Miniature circuit breaker
Residual current operated circuit breaker
Remote controlled mechanism
Undervoltage release
Shunt trip
Auxiliary switch
Fault signal contact

ST

AS

or

FC

or

UR

AS

or

AS
FC

AS
FC

or

FC

or

AS
FC

AS
FC

For further information on the mounting concept for RCBOs, please refer to the chapter, "Residual Current Protective Devices".

3/36

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Busbars
Standard 5ST3 6, 5ST3 7

Overview
The busbar system with pin-type connections can be used for all
5SL6 and 5SJ6 . . .-.KS miniature circuit breakers and 5SY miniature circuit breakers with or without mounted auxiliary switch
(AS) or fault signal contact (FC).
Busbars in 10 mm2 and 16 mm2 versions are available.

Any free pins on the busbars can be made safe by covering with
touch protection.
For further information on bus-mounting miniature circuit breakers with residual current operated circuit breakers, please refer
to the chapter "Residual current protective devices".

The 5ST3 7 busbar system with bars that can be cut to length
can be tailored to any requirements.
The extremely flexible 5ST3 6 busbar system with fixed lengths
also enables installation in any length as the busbars can be
overlapped.
No further need for time-consuming tasks, such as cutting, cutting to length, deburring, cleaning of cut surfaces and mounting
of end caps.

Benefits

Between the devices, the busbar, located at the bottom and


behind the conductor, provides an optimum wiring space with
easy view of the inserted conductor. This enables easy control
of connections.

The ability to overlap the busbar mounting enables a crosssection enlargement of up to 32 mm2 using the respective
components, 10 mm2 and 16 mm2.

By overlapping the busbars with fixed lengths, it is possible to


achieve device combinations with any number of devices.

The fact that the connection of the conductor is always clearly


visible facilitates control and insertion of conductors of all pole
types and considerably reduces mounting times.

Siemens LV 10.1 2011

3/37

Siemens AG 2011

Miniature Circuit Breakers


Busbars
Standard 5ST3 6, 5ST3 7

Technical specifications
5ST3
Standards

EN 60439-1 (VDE 0660-500): 2005-01

Busbar material

SF-Cu F 24

Partition material

Plastic, Cycoloy 3600


heat-resistant over 90 C
flame-retardant and
self-extinguishing,
dioxin and halogen-free
V AC

400

Cross-section 10 mm2
Cross-section 16 mm2

A
A

63
80

Rated impulse withstand voltage Uimp

kV

Test pulse voltage (1.2/50)

kV

6.2

Rated conditional short-circuit current Icc

kA

25

Rated operational voltage Uc


Rated current In

Resistance to climate
Constant atmosphere
Humid heat

Acc. to DIN 50015


Acc. to IEC 60068-2-30

23/83; 40/92; 55/20


28 cycles

Insulation coordination
Overvoltage category
Pollution degree

III
2

Maximum busbar current IS/phase


Infeed at the start of the busbar
- Cross-section 10 mm2
- Cross-section 16 mm2

A
A

63
80

Infeed at the center of the busbar


- Cross-section 10 mm2
- Cross-section 16 mm2

A
A

100
130

Infeed at the start or end of the busbar

Infeed along the busbar or midpoint infeed


3

I201_13754a

I201_13755

The sum of the output current per branch (1, 2, 3 ... n) must not be greater
than the max. busbar current IS/phase.

3/38

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Busbars
Standard 5ST3 6, 5ST3 7

Selection and ordering data


Pin
Length
spacing
MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.
kg

mm2,

5ST3 6 busbar systems, 10


for MCBs, fixed lengths,
cannot be cut, fully insulated
Single-phase
For 2 MCBs 1P
For 6 MCBs 1P
For 12 MCBs 1P

33
105
210

A
A
A

5ST3 600
5ST3 601
5ST3 602

1
1
1

10 units
10 units
10 units

027
027
027

0.009
0.019
0.047

1.5

40
156.5
237

A
A
A

5ST3 603
5ST3 604
5ST3 605

1
1
1

10 units
10 units
10 units

027
027
027

0.010
0.030
0.044

75.5
105
210

A
A
A

5ST3 606
5ST3 607
5ST3 608

1
1
1

10 units
10 units
10 units

027
027
027

0.018
0.027
0.063

102
157.5
210

A
A
}

5ST3 613
5ST3 614
5ST3 615

1
1
1

10 units
10 units
10 units

027
027
027

0.030
0.056
0.075

1+1+1.5 115
237
1.5
125
229

A
A

5ST3 616
5ST3 617

1
1

10 units
10 units

027
027

0.038
0.090

A
A

5ST3 618
5ST3 620

1
1

10 units
10 units

027
027

0.046
0.075

For 1 RCCB 4P N right


and 8 MCBs 1P

210

5ST3 624

10 units

027

0.077

For 1 RCCB 4P N left


and 8 MCBs 1P

192

5ST3 667

10 units

027

0.061

145
215
215

A
A
A

5ST3 621
5ST3 622
5ST3 623

1
1
1

10 units
10 units
10 units

027
027
027

0.055
0.093
0.087

33
105
210

A
A
A

5ST3 630
5ST3 631
5ST3 632

1
1
1

10 units
10 units
10 units

027
027
027

0.007
0.025
0.048

1.5

40
156.5
237

A
A
A

5ST3 633
5ST3 634
5ST3 635

1
1
1

10 units
10 units
10 units

027
027
027

0.010
0.029
0.052

75.5
105
210

A
A
A

5ST3 636
5ST3 637
5ST3 638

1
1
1

10 units
10 units
10 units

027
027
027

0.012
0.037
0.089

1 + 1.5

75.5
120.5
210

A
A
A

5ST3 640
5ST3 641
5ST3 642

1
1
1

10 units
10 units
10 units

027
027
027

0.024
0.048
0.081

Single-phase,
for MCBs with AS or FC
For 2 MCBs 1P
For 6 MCBs 1P
For 9 MCBs 1P
2-phase
For 2 MCBs 2P
For 3 MCBs 2P
For 6 MCBs 2P

Three-phase
For 2 MCBs 3P
For 3 MCBs 3P
For 4 MCBs 3P
Three-phase,
for MCBs with AS or FC
For 2 MCBs 3P
For 4 MCBs 3P
For 6 MCBs 1P
For 9 MCBs 1P
Three-phase

4-phase
For 2 MCBs 4P or 3P+N
For 3 MCBs 4P or 3P+N
For 6 MCBs 2P or 1P+N
5ST3 6 busbars, 16 mm2,
for MCBs, fixed lengths,
cannot be cut, fully insulated
Single-phase
For 2 MCBs 1P
For 6 MCBs 1P
For 12 MCBs 1P
Single-phase,
for MCBs with AS or FC
For 2 MCBs 1P
For 6 MCBs 1P
For 9 MCBs 1P
2-phase
For 2 MCBs 2P
For 3 MCBs 2P
For 6 MCBs 2P

2-phase,
for MCBs with AS or FC
For 2 MCBs 2P
For 3 MCBs 2P
For 5 MCBs 2P
1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/39

Siemens AG 2011

Miniature Circuit Breakers


Busbars
Standard 5ST3 6, 5ST3 7

Pin
Length
spacing
MW1)

mm

102.5
157.5
210

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

5ST3 6 busbars, 16 mm2,


for MCBs, fixed lengths,
cannot be cut, fully insulated
Three-phase
For 2 MCBs 3P
For 3 MCBs 3P
For 4 MCBs 3P

A
A
}

5ST3 643
5ST3 644
5ST3 645

1
1
1

10 units
10 units
10 units

027
027
027

0.047
0.085
0.119

1+1+1.5 115
237
1.5
156
245

A
A

5ST3 646
5ST3 647

1
1

10 units
10 units

027
027

0.052
0.126

A
A

5ST3 648
5ST3 650

1
1

10 units
10 units

027
027

0.067
0.110

For 1 RCCB 4P N right


and 8 MCBs 1P

210

5ST3 654

10 units

027

0.108

For 1 RCCB 4P N left


and 8 MCBs 1P

210

5ST3 668

10 units

027

0.099

A
A
A

5ST3 651
5ST3 652
5ST3 653

1
1
1

10 units
10 units
10 units

027
027
027

0.071
0.130
0.118

5ST3 655

10 units

027

0.003

5ST3 656

1 set

027

5.460

5ST3 657

1 set

027

7.650

A
A

5ST3 730
5ST3 732

1
1

1 unit
1 unit

027
027

0.032
0.034

1
1+1.5

A
A

5ST3 734
5ST3 736

1
1

1 unit
1 unit

027
027

0.070
0.072

1
1+1+1.5
1.5

}
A
A

5ST3 738
5ST3 741
5ST3 743

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.084
0.078
0.075

5ST3 745

1 unit

027

0.119

A
A

5ST3 731
5ST3 733

1
1

1 unit
1 unit

027
027

0.153
0.157

1
1+1.5

A
A

5ST3 735
5ST3 737

1
1

1 unit
1 unit

027
027

0.343
0.327

1
1+1+1.5
1.5

}
A
A

5ST3 740
5ST3 742
5ST3 744

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.440
0.421
0.420

5ST3 746

1 unit

027

0.600

Three-phase,
for MCBs with AS or FC
For 2 MCBs 3P
For 4 MCBs 3P
For 6 MCBs 1P
For 9 MCBs 1P
Three-phase,

4-phase
For 2 MCBs 4P or 3P+N
For 3 MCBs 4P or 3P+N
For 6 MCBs 2P or 1P+N

Touch protection
For free connections, yellow (RAL 1004)
5 x 1 pin

Range
10 mm2
20 5ST3 613 + 10 5ST3 614 +
50 5ST3 615 + 50 5ST3 655
16 mm2
20 5ST3 643 + 10 5ST3 644 +
50 5ST3 645 + 50 5ST3 655
5ST3 7 busbar systems, 10 mm2 12 MW,
for MCBs,
can be cut, with end caps
Single-phase, angled
For 12 MCBs 1P
For 9 MCBs 1P with AS or FC

1
1.5

214

2-phase
For 6 MCBs 2P
For 4 MCBs 2P with AS or FC
Three-phase
For 4 MCBs 3P
For 3 MCBs 3P with AS or FC
For 3 MCBs 1P with AS or FC
4-phase
For 3 MCBs 4P or 3P+N

5ST3 7 busbar systems, 10 mm2 56 MW,


for MCBs,
can be cut, without end caps
Single-phase, angled
For MCBs 1P
For MCBs 1P with AS or FC

1
1.5

1016

2-phase
For MCBs 2P
For MCBs 2P with AS or FC
Three-phase
For MCBs 3P
For MCBs 3P with AS or FC
For MCBs 1P with AS or FC
4-phase
For MCBs 4P or 3P+N
1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/40

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Busbars
Standard 5ST3 6, 5ST3 7
Pin
Length
spacing
MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.
kg

5ST3 7 busbar systems, 16 mm2 12 MW,


for MCBs,
can be cut, with end caps
Single-phase, angled
For MCBs 1P
For MCBs 1P with AS or FC

}
A

5ST3 700
5ST3 702

1
1

1 unit
1 unit

027
027

0.039
0.040

1
1+1.5

}
A

5ST3 704
5ST3 706

1
1

1 unit
1 unit

027
027

0.092
0.090

1
1+1+1.5
1.5

}
A
A

5ST3 708
5ST3 711
5ST3 713

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.116
0.098
0.098

5ST3 715

1 unit

027

0.142

}
}

5ST3 701
5ST3 703

1
1

1 unit
1 unit

027
027

0.196
0.185

1
1+1.5

}
}

5ST3 705
5ST3 707

1
1

1 unit
1 unit

027
027

0.452
0.446

1
1+1+1.5
1.5

}
}
}

5ST3 710
5ST3 712
5ST3 714

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.610
0.580
0.540

5ST3 716

1 unit

027

0.798

5ST3 770-2

10 units

027

0.400

5ST3 770-3

10 units

027

0.550

5ST3 770-4

10 units

027

0.100

5ST3 770-5

10 units

027

0.160

A
}
A

5ST3 748
5ST3 750
5ST3 718

1
1
1

10 units
10 units
10 units

027
027
027

0.001
0.001
0.001

1
1.5

214

2-phase
For MCBs 2P
For MCBs 2P with AS or FC
Three-phase
For MCBs 3P
For MCBs 3P with AS or FC
For MCBs 1P with AS or FC
4-phase
For MCBs 4P or 3P+N

5ST3 7 busbar systems, 16 mm2 56 MW,


for MCBs,
can be cut, without end caps
Single-phase, angled
For MCBs 1P
For MCBs 1P with AS or FC

1
1.5

1016

2-phase
For MCBs 2P
For MCBs 2P with AS or FC
Three-phase
For MCBs 3P
For MCBs 3P with AS or FC
For MCBs 1P with AS or FC
4-phase
For MCBs 4P or 3P+N

5ST3 7 busbar systems, 10 mm2 56 MW


can be cut, with end caps, with touch protection
4-phase
For MCBs 2P and RCBOs 1P+N 1

1008

5ST3 7 busbar systems, 16 mm2 56 MW


can be cut, with end caps, with touch protection
4-phase
For MCBs 2P and RCBOs 1P+N 1

1008

5ST3 7 busbar systems, 10 mm2 16 MW


can be cut, with end caps, with touch protection
4-phase
For 6 MCBs 1P+N and
RCCBs 4P, N connection, right

288

5ST3 7 busbar systems, 16 mm2 16 MW


can be cut, with end caps, with touch protection
4-phase
For 6 MCBs 1P+N and
RCCBs 4P, N connection, right

288

End caps for 5ST3 7, can be cut


For single-phase busbars
For two-phase and three-phase busbars
For 4-phase busbars

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/41

Siemens AG 2011

Miniature Circuit Breakers


Busbars
Standard 5ST3 6, 5ST3 7

Pin
Length
spacing
MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.
kg

5ST3 7 busbar systems, 10 mm2 12 MW,


for MCBs 1+N in 1 MW of the compact range,
can be cut, with end caps

Single-phase
For 12 MCBs 1+N, gray
For 12 MCBs 1+N, blue

1
1

216

A
A

5ST3 762
5ST3 763

1
1

10 units
10 units

027
027

0.022
0.001

A
A

5ST3 764
5ST3 765

1
1

10 units
10 units

027
027

0.134
0.134

A
A

5ST3 766
5ST3 767

1
1

10 set
10 set

027
027

0.001
0.001

5ST3 768

25 units

027

0.018

5ST3 7 busbar systems, 10 mm2 56 MW,


for MCBs 1+N in 1 MW of the compact range,
can be cut, without end caps

Single-phase
For MCBs 1+N, gray
For MCBs 1+N, blue

1
1

1016

End caps for 5ST3 76


1 set comprises a right and a left cap
Gray
Blue
Terminals for 5ST3 76
Terminal version S
For conductors up to 25 mm2

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/42

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Busbars
According to UL 508, 5ST3 7 . . - . HG

Overview
Products according to UL standards are used in North America,
but also in several other countries. This is important in particular
for exporting machines or electrical switchgear and equipment
to the USA. Acceptance and delivery are possible only if the relevant UL standards are satisfied.
The 5ST3 7 busbar system according to UL 508 and CSA is suitable for both universal use worldwide with all 5SY and 5SP miniature circuit breakers for Supplementary Protection certified according to UL 1077 and for 3NW and 3NC fuse holders certified
according to UL 512.

The busbars are available in single-, two- and three-phase version with different pin spacings and with two cross-sections
18 mm and 25 mm. Infeed can be directly into the terminals of
the miniature circuit breaker or through connection terminals.
The connection terminals are available in two versions for direct infeed at the busbar or for infeed directly at the miniature circuit breaker/fuse holder. Pins that are not required can be covered with touch protection covers.

Benefits

Bus-mounting with infeed through a connection terminal directly on the miniature circuit breaker up to a conductor crosssection of 35 mm

Infeed directly on the miniature circuit breaker up to a crosssection of 35 mm and connection terminal for connection
directly on the busbar up to a conductor cross-section of
50 mm
Suitable for universal use according to both IEC and UL standards
Can be used for 5SY, 5SP miniature circuit breakers and for
Class CC, cylindrical and SITOR fuse holders
UL-tested combination device and busbar
Different cross-sections 18 mm and 25 mm.

Bus mounting with infeed at the fuse holder for conductor


cross-sections up to 35 mm

Siemens LV 10.1 2011

3/43

Siemens AG 2011

Miniature Circuit Breakers


Busbars
According to UL 508, 5ST3 7 . . - . HG

Technical specifications
5ST3 7. .-0HG

5ST3 7. .-2HG

Standards

UL 508, CSA C22.2 No. 14-M 95

Approvals

UL 508 File No. E328403


CSA

5ST3 770-0HG

5ST3 770-1HG

Operational voltage
Acc. to IEC
Acc. to UL 508

V AC
V AC

690
600

Rated conditional short-circuit current

kA

10

Dielectric strength
Surge strength

kV/mm
kV

25
> 9.5

Rated current

--

--

115

A
A

80
160

100
200

---

---

25

--

--

Maximum busbar current IS/phase


Infeed at the start of the busbar
Infeed at the center of the busbar
Insulation coordination
Overvoltage category
Pollution degree

III
2
2

mm Cu 18

Busbar cross-section

Any

Infeed
Conductor cross-sections

AWG
mm2

---

---

10 ... 1/0
6 ... 35

14 ... 1
6 ... 50

Nm
lbs/in

---

---

5
50

3.5
35

Terminals
Terminal tightening torque

Infeed at the start or end of the busbar

Infeed along the busbar or midpoint infeed


3

I201_13754a

I201_13755

The sum of the output current per branch (1, 2, 3 ... n) must not be greater
than the max. busbar current IS/phase.

3/44

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


Busbars
According to UL 508, 5ST3 7 . . - . HG

Selection and ordering data


Pin
Length DT
spacing
MW1)

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.
kg

5ST3 7. .-.HG busbars according to UL 508, 18 mm2,


can be cut, without end caps
Single-phase
For MCBs 1P (5SY) or
fuse holders 10 x 38/class CC
(3NC1 091, 3NW7 513-0HG)

For MCBs 1P (5SY, 5SP) with AS or 1.5


FC or fuse holders 14 x 51
(3NC1 491, 3NW7 111)

1000

5ST3 701-0HG

10 units

012

0.330

1000

5ST3 703-0HG

10 units

012

0.330

2-phase
For MCBs 2P (5SY) or
fuse holders 10 x 38 class CC
(3NC1 092, 3NW7 523-0HG)

1000

5ST3 705-0HG

10 units

012

0.700

For MCBs 2P (5SY) with AS or FC

1+1.5

1000

5ST3 707-0HG

10 units

012

0.690

For MCBs 3P (5SY) or


fuse holders 10 x 38 class CC
(3NC1 093, 3NW7 533-0HG)

1000

5ST3 710-0HG

10 units

012

0.850

For MCBs 3P (5SY) with AS or FC

1+1+1.5 1000

Three-phase

For MCBs 1P (5SY, 5SP) with AS or 1.5


FC or fuse holders 14 x 51
(3NC1 493, 3NW7 131)

1000

5ST3 712-0HG

10 units

012

0.850

5ST3 714-0HG

10 units

012

0.850

5ST3 7. .-.HG busbars according to UL 508, 25 mm2,


can be cut, without end caps
Single-phase
For MCBs 1P (5SP) or
fuse holders 14 x 51
(3NC1 491, 3NW7 111)

1.5

1000

5ST3 701-2HG

10 units

012

0.340

1.5

1000

5ST3 705-2HG

10 units

012

0.800

1.5

1000

5ST3 710-2HG

10 units

012

1.090

For single-phase busbars

5ST3 748-0HG

10 units

012

0.001

For two- and three-phase busbars

5ST3 750-0HG

10 units

012

0.002

5ST3 770-0HG

10 units

012

0.035

5ST3 770-1HG

10 units

012

0.035

5ST3 655-0HG

10 units

012

0.005

2-phase
For MCBs 2P (5SP) or
fuse holders 14 x 51
(3NC1 492, 3NW7 121)
Three-phase
For MCBs 3P (5SP) or
fuse holders 14 x 51
(3NC1 493, 3NW7 131)
End caps for 5ST3 7. .-.HG

Terminals according to UL 508


Infeed to device
35 mm2

Infeed to busbar
50 mm2
Touch protection covers for busbars according to UL 508
5 x 1 pin

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/45

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

Overview
UL standards are used in North America as well as in several
other countries. This is of particular importance to European exporters of electrical switchgear equipment for machines who export to the USA, as their products will only be accepted if they
meet the relevant UL standards.

The key difference between the three device series is their application in different power supply systems.
5SJ4 -.HG40: 240/120 V AC, 1-pole, "same polarity only",
5SJ4 -.HG41: 240 V AC, 1-, 2- and 3-pole,
5SJ4 -.HG42: 480Y/277 V AC, 1-, 2- and 3-pole.

A wide range of low-voltage circuit protection devices from


Siemens comply with UL standards and are therefore suitable for
implementation worldwide in both IEC/EN and UL applications
within the framework of their specified use.

The terminals are suitable for "field wiring". This means that the
devices can be installed not only in factory-finished distribution
boards and control cabinets, but also on-site in a customer system.

Miniature circuit breakers certified to UL 489 permit use as an


all-round solution for protection tasks in distribution boards, control cabinets and control systems to UL 508A as "branch protectors". In particular, they are also approved for the protection of
electrical circuits in heating, ventilating and cooling systems
(HVAC), as well as for DC applications up to 60 V/125 V.

Using this mounting concept, all additional 5ST3 . . .-.HG components can be combined with miniature circuit breakers of the
5SJ4 -.HG range. The auxiliary switch (AS) signals the contact
position. In the event of a fault, the fault signal contact (FC) signals the automatic tripping of the MCB as well as the contact position. Shunt trips (ST) are used for the remote tripping of miniature circuit breakers. Captive metal brackets on the additional
components ensure fast mounting on the devices.

This covers a wide range of protection tasks, in residential and


non-residential buildings, as well as in industry. The tripping
characteristics B, C and D to EN/IEC 60898-1 have been
adapted so that they fall in the permissible tripping range according to UL 489, as well as for applications at 25 C and 40 C.
This means that the devices are approved for use according to
both standards. The enclosure dimensions of the devices correspond to DIN format. This means that the device series are suitable for universal use worldwide according to IEC or UL standards.

Single-, two- and three-phase busbars in 3 lengths with 6, 12 or


18 pins are available as accessories for all device series. The infeed is via connection terminals, which are available in two versions, for direct infeed at either the busbar or the miniature circuit breakers. Pins that are not required can be covered with
touch protection covers.

Benefits
Can be used globally for all applications in residential, nonresidential and industrial buildings. This facilitates the planning of plants and enhances export opportunities
The devices can be used according to IEC/EN 60898-1 and
UL 489, which means these devices can be installed anywhere in the world
Miniature circuit breakers with 480Y/277 V up to 40 A, with
240/120 V and 240 V up to 63 A
Can be used for both AC voltage and DC voltage up to 125 V
Rated switching capacity up to 14 kA in acc with UL 489 and
up to 15 kA in acc. with IEC 60947-2
Fast mounting with busbars up to 115 A and feeder terminals
up to 50 mm2.
Infeed direct at miniature circuit breaker for conductor crosssections up to 35 mm2

Bus mounting with central infeed directly on the busbar up to


conductor cross-section of 50 mm2

3/46

Siemens LV 10.1 2011

Accessories: Auxiliary switches, fault signal contacts and


shunt trips up to 480 V can be easily mounted onto the miniature circuit breaker.

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

Technical specifications
5SJ4 . . .-.HG40

5SJ4 . . .-.HG41

Standards

EN 60898-1; EN 60947-2; UL 489; UL-File E243414; CSA C22.2 No. 5-02

Approvals

See annex, chapter 20


B, C, D

Tripping characteristic

C, D

Operational voltage

Min.

V AC/DC

24

Acc. to IEC 60898-1

Max.
Max.

V DC/pole
V AC

60
250/440

Acc. to UL 489 and CSA C22.2 No.5-02

Max.

V AC
DC V/1P
DC V/2P

240/120
60
--

240
60
125

480Y/277
60
125

kA AC
kA AC
kA AC

10
15
14/101)

14/101)

101)

V AC

250
3/III

Rated breaking capacity


Icn acc. to IEC 60898-1
Icu acc. to IEC 60947-2
Acc. to UL 489 and CSA C22.2 No.5-02
Insulation coordination
Rated insulation voltage
Pollution degree for overvoltage category

250/440

Touch protection according to EN 50274

Yes

Handle end position, sealable

Yes

Degree of protection to EN 60529

IP20, with connected conductors

CFC and silicone-free

Yes

Mounting

On standard mounting rail

Terminals
Combined terminals at both ends
Terminal tightening torque, only for Cu, 60/75 C
Conductor cross-sections
Solid and stranded, acc. to UL489 and CSA C22.2 No.5-02
Solid and stranded, according to IEC 60898-1
Finely stranded, with end sleeve

Nm
lb. in

Yes
3.5
31

AWG
mm2
mm2

14 ... 4
0.75 ... 35
0.75 ... 25

Mains connection

Any

Mounting position

Any

Service life, on average, with rated load

20000 actuations

EMC environment
Acc. to EN 60947-2
Ambient temperature

Suitable for environment "B" (immunity to interference not applicable)


C

1)

-25 ... +45, occasionally +55, max. 95 % humidity,


storage temperature: -40 ... +75
6 cycles

Resistance to climate acc. to IEC 60068-2-30


Resistance to vibrations acc. to IEC 60068-2-6

5SJ4 . . .-.HG42

m/s2

50 at 25 ... 150 Hz and 60 at 35 Hz (4 sec)

For detailed information about the rated switching capacity, see engineering manual at: www.siemens.com/lowvoltage/manuals.

Additional components

Auxiliary switches
(AS)

Fault signal contacts Shunt trips (ST)


(FC)

5ST3 010-0HG
5ST3 011-0HG
5ST3 012-0HG

5ST3 020-0HG
5ST3 021-0HG
5ST3 022-0HG

5ST3 030-0HG

5ST3 031-0HG

UL 489, UL-File E243414;


CSA 22.2 No. 5-02

Standards

IEC/EN 62019, IEC/EN 60947-5-1

IEC/EN 60947-1

V AC
A AC

400
2

230
6 (NC: AC13, S: AC14)

110 ... 415


--

24 ... 60
--

V DC
A DC

220
1

110
1

60
3

24
6 (DC13)

---

24 ... 60
--

V AC
A AC

480
1.5

277
3

240
4

120
6

110 ... 480


--

24 ... 60
--

V DC
A DC

125
1

60
3

---

24 ... 60
--

Operational voltage/operational current (load)


Acc. to IEC

Acc. to UL

Short-circuit protection

Miniature circuit breaker or 6 A fuse

Minimum contact load

50 mA, 24 V

Tripping operations

--

Service life, on average, with rated load

12000 actuations

--

max. 2000

Primary operating range

x Un

--

0.7 ... 1.1

Conductor cross-sections

AWG
mm2

22 ... 14
0.5 ... 2.5

22 ... 14
0.5 ... 2.5

Nm
lb/in

0.5
4.5

0.8
6.8

Terminals
Terminal tightening torque

Siemens LV 10.1 2011

3/47

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

Version

Busbars

Terminals

Type

5ST3 663-.HG
5ST3 664-.HG
5ST3 665-.HG

5ST3 666-0HG

Standards

UL 489;
UL File No. E243414

Operational voltage
Acc. to IEC
Acc. to UL 489

V AC
V AC

690
480Y/277 and 240

Rated conditional short-circuit current


Dielectric strength
Surge strength

kA
kV/mm
kV

15 (with NH3 355A gL/gG 500 V)


30
> 9.5

Rated current at 40 C ambient temperature

115

Insulation coordination
Pollution degree
Overvoltage category

5ST3 666-2HG

2
III
mm2

Busbar cross-section (Cu)

16
Any

Infeed
Conductor cross-sections
AWG cables
Solid and stranded

AWG
mm2

---

14 ... 2
1.5 ... 35

14 ... 1
1.5 ... 50

Terminal tightening torque

Nm
lb. in

---

3.3
30

3.3
30

Temperature resistance

200 UL 94-V0/0.4 mm

Terminals

Selection and ordering data


Characteristic B
In

Mounting width

MW1)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs
"same polarity only"
1P, 240 V AC
6
10
13

1)

B
B
C

5SJ4 106-6HG40
5SJ4 110-6HG40
5SJ4 113-6HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.153
0.157
0.152

15
16
20

C
C
C

5SJ4 118-6HG40
5SJ4 116-6HG40
5SJ4 120-6HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.153
0.149
0.147

25
30
32

C
C
C

5SJ4 125-6HG40
5SJ4 130-6HG40
5SJ4 132-6HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.154
0.154
0.154

35
40
45

C
C
C

5SJ4 135-6HG40
5SJ4 140-6HG40
5SJ4 145-6HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.156
0.156
0.120

50
60
63

C
C
C

5SJ4 150-6HG40
5SJ4 160-6HG40
5SJ4 163-6HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.159
0.120
0.162

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/48

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC
Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs
"same polarity only"
1P, 240 V AC
0.3
1
C
0.5
C
1
B

5SJ4 114-7HG40
5SJ4 105-7HG40
5SJ4 101-7HG40

012 C
012 C
012 C

5SJ4 114-8HG40
5SJ4 105-8HG40
5SJ4 101-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.152
0.152
0.156

1.6
2
3

C
B
B

5SJ4 115-7HG40
5SJ4 102-7HG40
5SJ4 103-7HG40

012 C
012 C
012 C

5SJ4 115-8HG40
5SJ4 102-8HG40
5SJ4 103-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.151
0.151
0.139

4
5
6

B
C
B

5SJ4 104-7HG40
5SJ4 111-7HG40
5SJ4 106-7HG40

012 C
012 C
012 C

5SJ4 104-8HG40
5SJ4 111-8HG40
5SJ4 106-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.153
0.150
0.150

8
10
13

B
B
C

5SJ4 108-7HG40
5SJ4 110-7HG40
5SJ4 113-7HG40

012 C
012 C
012 C

5SJ4 108-8HG40
5SJ4 110-8HG40
5SJ4 113-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.152
0.151
0.147

15
16
20

C
B
B

5SJ4 118-7HG40
5SJ4 116-7HG40
5SJ4 120-7HG40

012 C
012 C
012 C

5SJ4 118-8HG40
5SJ4 116-8HG40
5SJ4 120-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.153
0.152
0.152

25
30
32

B
C
C

5SJ4 125-7HG40
5SJ4 130-7HG40
5SJ4 132-7HG40

012 C
012 C
012 C

5SJ4 125-8HG40
5SJ4 130-8HG40
5SJ4 132-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.152
0.158
0.156

35
40
45

C
C
C

5SJ4 135-7HG40
5SJ4 140-7HG40
5SJ4 145-7HG40

012 C
012 C
012 C

5SJ4 135-8HG40
5SJ4 140-8HG40
5SJ4 145-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.161
0.156
0.159

50
60
63

C
C
C

5SJ4 150-7HG40
5SJ4 160-7HG40
5SJ4 163-7HG40

012 C
012 C
012 C

5SJ4 150-8HG40
5SJ4 160-8HG40
5SJ4 163-8HG40

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.159
0.157
0.157

C
C
C

5SJ4 114-7HG41
5SJ4 105-7HG41
5SJ4 101-7HG41

012 C
012 C
012 C

5SJ4 114-8HG41
5SJ4 105-8HG41
5SJ4 101-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.175

1.6
2
3

C
C
C

5SJ4 115-7HG41
5SJ4 102-7HG41
5SJ4 103-7HG41

012 C
012 C
012 C

5SJ4 115-8HG41
5SJ4 102-8HG41
5SJ4 103-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.168
0.171

4
5
6

C
C
C

5SJ4 104-7HG41
5SJ4 111-7HG41
5SJ4 106-7HG41

012 C
012 C
012 C

5SJ4 104-8HG41
5SJ4 111-8HG41
5SJ4 106-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.170
0.155
0.169

8
10
13

C
C
C

5SJ4 108-7HG41
5SJ4 110-7HG41
5SJ4 113-7HG41

012 C
012 C
012 C

5SJ4 108-8HG41
5SJ4 110-8HG41
5SJ4 113-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.172
0.173
0.172

15
16
20

C
C
C

5SJ4 118-7HG41
5SJ4 116-7HG41
5SJ4 120-7HG41

012 C
012 C
012 C

5SJ4 118-8HG41
5SJ4 116-8HG41
5SJ4 120-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.172
0.171

25
30
32

C
C
C

5SJ4 125-7HG41
5SJ4 130-7HG41
5SJ4 132-7HG41

012 C
012 C
012 C

5SJ4 125-8HG41
5SJ4 130-8HG41
5SJ4 132-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.172
0.155
0.155

35
40
45

C
C
C

5SJ4 135-7HG41
5SJ4 140-7HG41
5SJ4 145-7HG41

012 C
012 C
012 C

5SJ4 135-8HG41
5SJ4 140-8HG41
5SJ4 145-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.175
0.155

50
60
63

C
C
C

5SJ4 150-7HG41
5SJ4 160-7HG41
5SJ4 163-7HG41

012 C
012 C
012 C

5SJ4 150-8HG41
5SJ4 160-8HG41
5SJ4 163-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

MCBs
1P, 240 V AC
0.3
0.5
1

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/49

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs
2P, 240 V AC
0.3
0.5
1

C
C
C

5SJ4 214-7HG41
5SJ4 205-7HG41
5SJ4 201-7HG41

012 C
012 C
012 C

5SJ4 214-8HG41
5SJ4 205-8HG41
5SJ4 201-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.341
0.337

1.6
2
3

C
C
C

5SJ4 215-7HG41
5SJ4 202-7HG41
5SJ4 203-7HG41

012 C
012 C
012 C

5SJ4 215-8HG41
5SJ4 202-8HG41
5SJ4 203-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.332
0.332
0.329

4
5
6

C
C
C

5SJ4 204-7HG41
5SJ4 211-7HG41
5SJ4 206-7HG41

012 C
012 C
012 C

5SJ4 204-8HG41
5SJ4 211-8HG41
5SJ4 206-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.329
0.310
0.335

8
10
13

C
C
C

5SJ4 208-7HG41
5SJ4 210-7HG41
5SJ4 213-7HG41

012 C
012 C
012 C

5SJ4 208-8HG41
5SJ4 210-8HG41
5SJ4 213-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.337
0.332
0.332

15
16
20

C
C
C

5SJ4 218-7HG41
5SJ4 216-7HG41
5SJ4 220-7HG41

012 C
012 C
012 C

5SJ4 218-8HG41
5SJ4 216-8HG41
5SJ4 220-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.335
0.334

25
30
32

C
C
C

5SJ4 225-7HG41
5SJ4 230-7HG41
5SJ4 232-7HG41

012 C
012 C
012 C

5SJ4 225-8HG41
5SJ4 230-8HG41
5SJ4 232-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.333
0.336
0.342

35
40
45

C
C
C

5SJ4 235-7HG41
5SJ4 240-7HG41
5SJ4 245-7HG41

012 C
012 C
012 C

5SJ4 235-8HG41
5SJ4 240-8HG41
5SJ4 245-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.343
0.310

50
60
63

C
C
C

5SJ4 250-7HG41
5SJ4 260-7HG41
5SJ4 263-7HG41

012 C
012 C
012 C

5SJ4 250-8HG41
5SJ4 260-8HG41
5SJ4 263-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.343
0.310
0.310

C
C
C

5SJ4 314-7HG41
5SJ4 305-7HG41
5SJ4 301-7HG41

012 C
012 C
012 C

5SJ4 314-8HG41
5SJ4 305-8HG41
5SJ4 301-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

1.6
2
3

C
C
C

5SJ4 315-7HG41
5SJ4 302-7HG41
5SJ4 303-7HG41

012 C
012 C
012 C

5SJ4 315-8HG41
5SJ4 302-8HG41
5SJ4 303-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.488
0.486

4
5
6

C
C
C

5SJ4 304-7HG41
5SJ4 311-7HG41
5SJ4 306-7HG41

012 C
012 C
012 C

5SJ4 304-8HG41
5SJ4 311-8HG41
5SJ4 306-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.484
0.465
0.489

8
10
13

C
C
C

5SJ4 308-7HG41
5SJ4 310-7HG41
5SJ4 313-7HG41

012 C
012 C
012 C

5SJ4 308-8HG41
5SJ4 310-8HG41
5SJ4 313-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.498
0.492
0.494

15
16
20

C
C
C

5SJ4 318-7HG41
5SJ4 316-7HG41
5SJ4 320-7HG41

012 C
012 C
012 C

5SJ4 318-8HG41
5SJ4 316-8HG41
5SJ4 320-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.499
0.506
0.495

25
30
32

C
C
C

5SJ4 325-7HG41
5SJ4 330-7HG41
5SJ4 332-7HG41

012 C
012 C
012 C

5SJ4 325-8HG41
5SJ4 330-8HG41
5SJ4 332-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.494
0.504
0.504

35
40
45

C
C
C

5SJ4 335-7HG41
5SJ4 340-7HG41
5SJ4 345-7HG41

012 C
012 C
012 C

5SJ4 335-8HG41
5SJ4 340-8HG41
5SJ4 345-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.505
0.465

50
60
63

C
C
C

5SJ4 350-7HG41
5SJ4 360-7HG41
5SJ4 363-7HG41

012 C
012 C
012 C

5SJ4 350-8HG41
5SJ4 360-8HG41
5SJ4 363-8HG41

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.499
0.465
0.465

MCBs
3P, 240 V AC
0.3
0.5
1

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/50

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC
Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

MCBs
1P,
480Y/277 V AC
0.3
0.5
1

C
C
C

5SJ4 114-7HG42
5SJ4 105-7HG42
5SJ4 101-7HG42

012 C
012 C
012 C

5SJ4 114-8HG42
5SJ4 105-8HG42
5SJ4 101-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

1.6
2
3

C
C
C

5SJ4 115-7HG42
5SJ4 102-7HG42
5SJ4 103-7HG42

012 C
012 C
012 C

5SJ4 115-8HG42
5SJ4 102-8HG42
5SJ4 103-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

4
5
6

C
C
C

5SJ4 104-7HG42
5SJ4 111-7HG42
5SJ4 106-7HG42

012 C
012 C
012 C

5SJ4 104-8HG42
5SJ4 111-8HG42
5SJ4 106-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

8
10
13

C
C
C

5SJ4 108-7HG42
5SJ4 110-7HG42
5SJ4 113-7HG42

012 C
012 C
012 C

5SJ4 108-8HG42
5SJ4 110-8HG42
5SJ4 113-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

15
16
20

C
C
C

5SJ4 118-7HG42
5SJ4 116-7HG42
5SJ4 120-7HG42

012 C
012 C
012 C

5SJ4 118-8HG42
5SJ4 116-8HG42
5SJ4 120-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

25
30
32

C
C
C

5SJ4 125-7HG42
5SJ4 130-7HG42
5SJ4 132-7HG42

012 C
012 C
012 C

5SJ4 125-8HG42
5SJ4 130-8HG42
5SJ4 132-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.155
0.155
0.155

35
40

C
C

5SJ4 135-7HG42
5SJ4 140-7HG42

012
012

---

1
1

1 unit
1 unit

C
C
C

5SJ4 214-7HG42
5SJ4 205-7HG42
5SJ4 201-7HG42

012 C
012 C
012 C

5SJ4 214-8HG42
5SJ4 205-8HG42
5SJ4 201-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.310
0.310

1.6
2
3

C
C
C

5SJ4 215-7HG42
5SJ4 202-7HG42
5SJ4 203-7HG42

012 C
012 C
012 C

5SJ4 215-8HG42
5SJ4 202-8HG42
5SJ4 203-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.310
0.310

4
5
6

C
C
C

5SJ4 204-7HG42
5SJ4 211-7HG42
5SJ4 206-7HG42

012 C
012 C
012 C

5SJ4 204-8HG42
5SJ4 211-8HG42
5SJ4 206-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.310
0.310

8
10
13

C
C
C

5SJ4 208-7HG42
5SJ4 210-7HG42
5SJ4 213-7HG42

012 C
012 C
012 C

5SJ4 208-8HG42
5SJ4 210-8HG42
5SJ4 213-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.310
0.310

15
16
20

C
C
C

5SJ4 218-7HG42
5SJ4 216-7HG42
5SJ4 220-7HG42

012 C
012 C
012 C

5SJ4 218-8HG42
5SJ4 216-8HG42
5SJ4 220-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.310
0.310

25
30
32

C
C
C

5SJ4 225-7HG42
5SJ4 230-7HG42
5SJ4 232-7HG42

012 C
012 C
012 C

5SJ4 225-8HG42
5SJ4 230-8HG42
5SJ4 232-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.310
0.310
0.310

35
40

C
C

5SJ4 235-7HG42
5SJ4 240-7HG42

012
012

---

1
1

1 unit
1 unit

0.155
0.155

MCBs
2P,
480Y/277 V AC
0.3
0.5
1

1)

0.310
0.310

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/51

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

Characteristic C
In

Mount- DT
ing
width

MW1)

Order No.

Characteristic D
Price
per PU

PG DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MCBs
3P,
480Y/277 V AC
0.3
0.5
1

C
C
C

5SJ4 314-7HG42
5SJ4 305-7HG42
5SJ4 301-7HG42

012 C
012 C
012 C

5SJ4 314-8HG42
5SJ4 305-8HG42
5SJ4 301-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

1.6
2
3

C
C
C

5SJ4 315-7HG42
5SJ4 302-7HG42
5SJ4 303-7HG42

012 C
012 C
012 C

5SJ4 315-8HG42
5SJ4 302-8HG42
5SJ4 303-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

4
5
6

C
C
C

5SJ4 304-7HG42
5SJ4 311-7HG42
5SJ4 306-7HG42

012 C
012 C
012 C

5SJ4 304-8HG42
5SJ4 311-8HG42
5SJ4 306-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

8
10
13

C
C
C

5SJ4 308-7HG42
5SJ4 310-7HG42
5SJ4 313-7HG42

012 C
012 C
012 C

5SJ4 308-8HG42
5SJ4 310-8HG42
5SJ4 313-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

15
16
20

C
C
C

5SJ4 318-7HG42
5SJ4 316-7HG42
5SJ4 320-7HG42

012 C
012 C
012 C

5SJ4 318-8HG42
5SJ4 316-8HG42
5SJ4 320-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

25
30
32

C
C
C

5SJ4 325-7HG42
5SJ4 330-7HG42
5SJ4 332-7HG42

012 C
012 C
012 C

5SJ4 325-8HG42
5SJ4 330-8HG42
5SJ4 332-8HG42

1
1
1

1 unit
1 unit
1 unit

012
012
012

0.465
0.465
0.465

35
40

C
C

5SJ4 335-7HG42
5SJ4 340-7HG42

012
012

---

1
1

1 unit
1 unit

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

Mount- DT
ing
width

Order No.

0.465
0.465

PG

MW1)

Weight
per PU
approx.
kg

Auxiliary switches (AS) acc. to UL 489


1 NO + 1 NC

5ST3 010-0HG

1 unit

012

0.071

2 NO

0.5

5ST3 011-0HG

1 unit

012

0.050

2 NC

5ST3 012-0HG

1 unit

012

0.050

Fault signal contacts (FC) acc. to UL 489


1 NO + 1 NC

5ST3 020-0HG

1 unit

012

0.050

2 NO

0.5

5ST3 021-0HG

1 unit

012

0.050

2 NC

5ST3 022-0HG

1 unit

012

0.050

5ST3 030-0HG

1 unit

012

0.098

5ST3 031-0HG

1 unit

012

0.098

Shunt trips (ST) acc. to UL 489


110 ... 480 V AC
24 ... 60 V AC/DC

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

3/52

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

Accessories
Pin spacing

Length

MW1)

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Busbars according to UL 489


specially for 5SJ4 ... -.HG.. MCBs,
fixed length, cannot be cut2)
UL-File E321559
Single-phase
For 6 MCBs 1P
For 12 MCBs 1P
For 18 MCBs 1P

100
205
310

A
A
A

5ST3 663-0HG
5ST3 663-1HG
5ST3 663-2HG

1 10 units
1 10 units
1 10 units

012
012
012

0.056
0.112
0.170

100
205
310

A
A
A

5ST3 664-0HG
5ST3 664-1HG
5ST3 664-2HG

1 10 units
1 10 units
1 10 units

012
012
012

0.065
0.137
0.211

100
205
310

A
A
A

5ST3 665-0HG
5ST3 665-1HG
5ST3 665-2HG

1 10 units
1 10 units
1 10 units

012
012
012

0.067
0.155
0.243

Infeed at the miniature circuit breaker


Max. 35 mm2

5ST3 666-0HG

1 10 units

012

0.033

Infeed at the busbar


Max. 50 mm2

5ST3 666-2HG

1 10 units

012

0.034

3 1 pin

5ST3 666-1HG

1 10 units

012

0.003

Handle locking devices according to UL,


UL-File E321559

5ST3 801

1 unit

027

0.012

5ST3 802

1 unit

027

0.031

2-phase
For 3 MCBs 2P
For 6 MCBs 2P
For 9 MCBs 2P
Three-phase
For 2 MCBs 3P
For 4 MCBs 3P
For 6 MCBs 3P

Terminals according to UL 489


specially for 5SJ4 ... -.HG.. MCBs

Touch protection covers


for busbars acc. to UL 489

Can be sealed against unwanted manual ON/OFF switching, padlock with max. 3 mm shackle

Padlocks
For 5ST3 801 handle locking device

1)

1 MW (modular width) = 18 mm.

2)

All unassigned pins of the busbar must be covered with 5ST3 666-1HG
touch protection covers.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/53

Siemens AG 2011

Miniature Circuit Breakers


5SJ4 . . . - . HG miniature circuit breaker
and accessories, according to UL 489 and IEC

More information
Mounting concept for mounting 5ST3 0. .-0HG accessories on
5SJ4 . . .-.HG miniature circuit breakers
The diagram shows which additional components can be
mounted on the right.

2 auxiliary switches (AS) or fault signal contacts (FC) can


be mounted to the right of the miniature circuit breaker
(CB) in any combination
5ST30.

or

5SJ4 ...-.HG..

or

FC

AS

or

AS
FC

AS
FC

AS
FC

FC
AS

AS
FC

FC
AS

I2_18121

CB

or

ST

AS

or

FC

or

AS
FC

AS
FC

Max. 1 shunt trip (ST) can be mounted on the right of the


miniature circuit breaker (CB). 2 auxiliary switches (AS)
or fault signal contacts (FC) can also be mounted to the
right of the ST in any combination

CB:
ST:
AS:
FC:

Circuit breaker
Shunt trip
Auxiliary switch
Fault signal contact

3/54

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SP3 main miniature circuit breakers, SHU

Overview

Benefits

Selective main miniature circuit breakers are used as circuit


breakers at meter panels and provide an optimum solution.
Characteristic E is adapted to the special application requirements for cascade circuits between melting fuses and miniature
circuit breakers in distributor circuits.
An integrated adapter enables quick and easy mounting of the
devices on 40-mm busbars. The reduced width of 1.5 MW creates lots of additional space in the meter cabinet.
The screwless outgoing terminal provides optimum user-friendliness.

Used in conjunction with the downstream miniature circuit


breaker, selective main miniature circuit breakers ensure effective protection and optimum availability of the system.

Quick and easy installation due to direct bus-mounting


Space saving field installation due to reduced mounting width
Tool-free connection of meter cable
Reliable and high selectivity
Optimum availability of customer system
Voltage-independent operation of selective main miniature circuit breakers
Practical locking options
Excellent current limitation characteristics increase plant protection, thanks to the selective main miniature circuit breakers
supporting downstream miniature circuit breakers.
High and safe selectivity between sub-distribution and meter
panel ensures the continued supply of the unaffected circuits
in the event of a fault, thus improving plant availability
The selective main miniature circuit breaker prevents the
affected circuit from being reconnected until the fault is eliminated. Greater safety during operation
No previous knowledge required for operation of the selective
main miniature circuit breakers. This ensures fast and safe disconnection and reconnection of loads.
Complies with all the requirements of TAB 2007.

Technical specifications
5SP3 7. ., 5SP3 7. .-1

5SP3 7. .-2,
5SP3 7. .-2KK0.

DIN VDE 0645

E DIN VDE 0641-21

V AC
V AC

230/400
400

--

V AC
V AC

110
440

Rated frequency

Hz

50 ... 60

Rated current In

16 ... 100

Rated insulation voltage Ui

V AC

690

Rated switching capacity Icn

25000

Standards
Rated voltage Un
1-pole
3 x 1-pole
Operational voltage

Min.
Max.

5SP3 8. .-2

-400

16 ... 63

Insulation coordination
Overvoltage category
Pollution degree
Surge strength Uimp

IV
3
kV

Impact resistance

30 g, at least 3 impacts, impact duration 11 ms

Resistance to vibrations

2 g, 20 frequency cycles 5 ... 150 ... 15 Hz


OFF = green, ON = red

Switching position indication


Main conductor characteristics

Acc. to EN 60204-1

Handle end position, sealable

Yes
Yes

Cutoff

ON/OFF

--

Device depth

mm

92

Locking slide with lock, additional wire seal, cable


ties and Antilux

Degree of protection

IP20, with connected conductors

Mains connection

Any

Mounting position

Any

Mounting

On standard mounting rail Direct tool-free mounting on the busbar system


or interface adapter

Service life, on average, with rated load


Conductor connections

Actuations

20000
Saddle terminals at both
ends

Top

Screwless spring terminal for flexible cables,


in particular for meter connecting cables acc. to
DIN 43870-3

Bottom

Box terminal, also for infeed of the busbar system,


up to 100 A input terminal current

Siemens LV 10.1 2011

3/55

Siemens AG 2011

Miniature Circuit Breakers


5SP3 main miniature circuit breakers, SHU

5SP3 7. ., 5SP3 7. .-1

5SP3 7. .-2,
5SP3 7. .-2KK0.

mm2
mm2

2.5 ... 70
2.5 ... 50

---

mm2
2

---

2.5 ... 16
2.5 ... 50

Storage temperature

-40 ... +70

Ambient temperature

-25 ... +55

5SP3 8. .-2

Conductor cross-sections
Top and bottom, solid and stranded
Top and bottom, finely stranded

Top, finely stranded


Bottom, solid, stranded and finely stranded, with end sleeve mm

Selection and ordering data


In

Mount- DT
ing
width

MW1)

Main miniature circuit breakers, 1P, L1

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For direct bus-mounting (spacing: 40 mm), no further


accessories required
16
20
25

C
C
C

5SP3 716-2KK01
5SP3 720-2KK01
5SP3 725-2KK01

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.400
0.400
0.400

35
40
50

C
C
C

5SP3 735-2KK01
5SP3 740-2KK01
5SP3 750-2KK01

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.400
0.400
0.400

63

5SP3 763-2KK01

1 unit

005

0.400

C
C
C

5SP3 716-2KK02
5SP3 720-2KK02
5SP3 725-2KK02

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.400
0.400
0.400

35
40
50

C
C
C

5SP3 735-2KK02
5SP3 740-2KK02
5SP3 750-2KK02

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.400
0.400
0.400

63

5SP3 763-2KK02

1 unit

005

0.400

C
C
C

5SP3 716-2KK03
5SP3 720-2KK03
5SP3 725-2KK03

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.400
0.400
0.400

35
40
50

C
C
C

5SP3 735-2KK03
5SP3 740-2KK03
5SP3 750-2KK03

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.400
0.400
0.400

63

5SP3 763-2KK03

1 unit

005

0.400

C
C
C

5SP3 716-2
5SP3 720-2
5SP3 725-2

1
1
1

1 set
1 set
1 set

005
005
005

1.275
1.275
1.275

35
40
50

C
C
C

5SP3 735-2
5SP3 740-2
5SP3 750-2

1
1
1

1 set
1 set
1 set

005
005
005

1.275
1.275
1.275

63

5SP3 763-2

1 set

005

1.275

C
C
C

5SP3 816-2
5SP3 820-2
5SP3 825-2

1
1
1

1 unit
1 unit
1 unit

005
005
005

1.275
1.275
1.275

35
40
50

C
C
C

5SP3 835-2
5SP3 840-2
5SP3 850-2

1
1
1

1 unit
1 unit
1 unit

005
005
005

1.275
1.275
1.275

63

5SP3 863-2

1 unit

005

1.275

Main miniature circuit breakers, 1P, L2

1.5

For direct bus-mounting (spacing: 40 mm), no further


accessories required
16
20
25

Main miniature circuit breakers, 1P, L3

1.5

For direct bus-mounting (spacing: 40 mm), no further


accessories required
16
20
25

1.5

Main miniature circuit breakers, 1P


each1x L1, L2, L3, packaged as set
For direct bus-mounting (spacing: 40 mm), no further
accessories required
16
20
25

3 x 1.5

Main miniature circuit breakers, 3 x 1P


single-pole switching
For direct bus-mounting (spacing: 40 mm), no further
accessories required
16
20
25

1)

4.5

1 MW (modular width) = 18 mm.


* You can order this quantity or a multiple thereof.

3/56

Siemens LV 10.1 2011

Siemens AG 2011

Miniature Circuit Breakers


5SP3 main miniature circuit breakers, SHU
In

Mount- DT
ing
width

MW1)

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Main miniature circuit breakers, 1P


For mounting on standard mounting rail, busbar (spacing:
40 mm, with 5ST1 busbar adapter), or for screw fixing
16
20

C
C

5SP3 716
5SP3 720

1
1

1 unit
1 unit

005
005

0.474
0.461

25
32
35

C
C
C

5SP3 725
5SP3 732
5SP3 735

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.497
0.465
0.497

40
50
63

C
C
C

5SP3 740
5SP3 750
5SP3 763

1
1
1

1 unit
1 unit
1 unit

005
005
005

0.461
0.501
0.517

80
100

C
C

5SP3 780
5SP3 791

1
1

1 unit
1 unit

005
005

0.512
0.487

C
C

5SP3 780-1
5SP3 791-1

1
1

1 set
1 set

005
005

1.827
1.855

5ST1 322

1 10 units

005

0.025

5ST1 328

1 unit

005

0.256

5ST1 318

1 10 units

005

0.003

5ST1 323

3 units

005

0.011

5ST1 316

6 units

005

0.004

Main miniature circuit breakers, 3 x 1P


Premounted on 5ST1 324 busbar adapter; can be clipped
onto busbars (spacing: 40 mm); including three 5ST1 323
transparent operating protective covers
80
100

Mounting plates
For mounting on standard mounting rails according to EN 50022
For 1 or 2 standard mounting rails, universal application, tier spacing 125 mm

Busbar adapters for 5SP3 7. . and 5SP3 7. .-1


Suitable for busbar spacing 40 mm
can be equipped with 3 selective main miniature circuit breakers

Breaker blocking covers for 5SP3 7. . and 5SP3 7. .-1


To prevent manual off-switching

Operating protective covers, transparent, for 5SP3 7. .


and 5SP3 7. .-1
Multiple locking options against accidental and
intentional operation
Padlocks
Phillips screwdrivers
Special wrenches (Antilux)
These can be installed by the operator or the
power supply company
Terminal covers for 5SP3 7. . and 5SP3 7. .-1
2 units required per contactor
Terminal covers in compliance with cladding
dimensions acc. to DIN 43880

1)

1 MW (modular width) = 18 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/57

Siemens AG 2011

Miniature Circuit Breakers


5SK9 circuit breaker terminals

Overview

Benefits

Circuit breaker terminals are used for short-circuit protection or


for protection against overloading and short-circuiting in auxiliary and control circuits after control transformers. All terminals
are designed for 2 wires. The terminal block labeling accessories are used for inscription.

Integration of line protection switching function in the terminal


technology of control cabinets in compact 12 mm design
Display of switching position or the "Tripped" state for the fast
detection of faults
Switching/isolating function facilitates fault locating
Device versions with integrated auxiliary switch (AS) signal
the contact position
Device versions with floating through-type connection parallel
to the switching contacts facilitate line connection
These devices are listed as "Supplementary Protectors" according to UL 1077 (UL Recognized Components) and CSA 235
(CSA Component Accepted).

Technical specifications
5SK9 011-1KK2.,
5SK9 011-2KK2.

5SK9 011-4KK2.,
5SK9 011-6KK2.,
5SK9 011-8KK2.

DIN VDE 0660-101, IEC/EN 60947-2, UL 1077

Standards
Rated operational voltage

Max.

AC

250 V at 50/60 Hz

DC

60 V

Operational voltage

Min.

V AC/DC

24

Power loss

Max.

kV

Rated impulse withstand voltage


Pollution degree

Acc. to EN 60664-1

Rated current of through-type connection

16

Rated operational current of auxiliary switch

Mechanical service life

Actuations

16000

Electrical service life, on average, with rated load

Actuations

8000

Polarity with direct current

Any

Mounting position

Any

Resistance to vibrations

10 g at  70 Hz

Enclosures

With thermoplastic insulating body


Screw connection at both ends for 2 conductors each
Enclosed on both sides

Touch protection

Acc. to EN 50274-1

Yes

Terminal size

mm2

1.5

Terminal tightening torque, recommended

Nm

0.8

Solid

mm2

1 or 2 (0.75 ... 1.5)

Finely stranded, with end sleeve

mm2

1 or 2 (1 ... 2.5)

2.5

Conductor cross-sections

UAWG 14-12

Yes

--

sAWG 14

Yes

--

Stripped length

3/58

Siemens LV 10.1 2011

mm

10

Siemens AG 2011

Miniature Circuit Breakers


5SK9 circuit breaker terminals

Selection and ordering data


Version

In

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

A
Terminal size 1.5 mm2
With short-circuit release
1
2
4

}
}
A

5SK9 011-1KK24
5SK9 011-1KK25
5SK9 011-1KK26

1
1
1

10 units
10 units
10 units

027
027
027

0.053
0.052
0.053

6
10

}
A

5SK9 011-1KK27
5SK9 011-1KK28

1
1

10 units
10 units

027
027

0.053
0.050

1
2
4

}
}
}

5SK9 011-2KK24
5SK9 011-2KK25
5SK9 011-2KK26

1
1
1

10 units
10 units
10 units

027
027
027

0.053
0.052
0.053

6
10

}
A

5SK9 011-2KK27
5SK9 011-2KK28

1
1

10 units
10 units

027
027

0.053
0.050

A
A
A

5SK9 011-6KK24
5SK9 011-6KK25
5SK9 011-6KK26

1
1
1

5 units
5 units
5 units

027
027
027

0.096
0.093
0.092

A
A

5SK9 011-6KK27
5SK9 011-6KK28

1
1

5 units
5 units

027
027

0.093
0.090

A
}
}

5SK9 011-4KK24
5SK9 011-4KK25
5SK9 011-4KK26

1
1
1

5 units
5 units
5 units

027
027
027

0.089
0.092
0.091

6
10

A
B

5SK9 011-4KK27
5SK9 011-4KK28

1
1

5 units
5 units

027
027

0.105
0.088

0.5
1
2

A
}
}

5SK9 011-8KK23
5SK9 011-8KK24
5SK9 011-8KK25

1
1
1

5 units
5 units
5 units

027
027
027

0.092
0.092
0.097

4
6
10

D
}
B

5SK9 011-8KK26
5SK9 011-8KK27
5SK9 011-8KK28

1
1
1

5 units
5 units
5 units

027
027
027

0.092
0.090
0.090

Feeder terminals
Rated uninterrupted current 76 A
Connection up to 16 mm

5ST1 822-7KK00

10 units

027

0.010

Link rails, single-phase


Rated uninterrupted current 65 A

5ST1 822-7KK02

20 units

027

0.023

9 connections
104 mm long
For terminals: 5SK9 011-1KK2.,
5SK9 011-2KK2.

5ST1 822-7KK07

20 units

027

0.016

10 connections
206 mm long
For terminals: 5SK9 011-4KK2.,
5SK9 011-6KK2.

5ST1 822-7KK01

20 units

027

0.030

18 connections
206 mm long
For terminals: 5SK9 011-1KK2.,
5SK9 011-2KK2.

5ST1 822-7KK06

20 units

027

0.037

5 connections/pole
104 mm long

5ST1 822-7KK04

10 units

027

0.032

9 connections/pole
206 mm long

5ST1 822-7KK03

10 units

027

0.061

With overload and short-circuit release

Terminal size 2.5 mm2


With short-circuit release, auxiliary switch
with 1 NO and 1 NC
1
2
4
6
10
With overload and short-circuit release, auxiliary
switch with 1 NC and
through-type connection
1
2
4

With overload and short-circuit release,


auxiliary switch with 1 NO and 1 NC

5ST1 822-7KK02

5ST1 822-7KK06

5 connections
104 mm long
For terminals: 5SK9 011-4KK2.,
5SK9 011-6KK2., 5SK9 011-8KK2.

Link rails, two-phase


Rated uninterrupted current 120 A
for terminal 5SK9 011-4KK2.
5ST1 822-7KK04

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

3/59

Siemens AG 2011

Miniature Circuit Breakers


Notes

3/60

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current
Protective Devices
4/2

Introduction

4/3
4/5
4/6

5SM3 RCCBs, Type AC and Type A


5SM3 RCCBs, Type AC
5SM3 RCCBs, Type A

4/9

SIQUENCE 5SM3 and 5SU1


Universal Current-Sensitive
RCCBs, Type B and Type B+

4/13

Additional Components

4/15

5SM2 RC Units, Type A

4/18

5SU1 RCBOs, Type AC and Type A

4/23

Busbars

4/26

5SM1 and 5SZ9 RCCB Socket


Outlets

4/27

Accessories

4/28

Residual-Current Operated Circuit


Breakers
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices


Introduction

Page

Field of application

Residential
buildings

Industry

Devices

Non-residential
buildings

Overview
Standards

4/3

Personnel, material and fire protection, IEC/EN 61008


as well as protection against direct contact. SIGRES with active condensation
protection for use in harsh environments. Super resistant and selective
versions

SIQUENCE, the technology of universal VDE 0664-100


current-sensitive residual current proVDE 0664-200
tective devices
VDE V 0664-110

--

Remote controlled mechanisms, auxiliary switches for all residual current


operated circuit breakers.

IEC/EN 62019

--

4
5SM3 RCCBs, type AC and type A

SIQUENCE 5SM3 and 5SU1 universal 4/9


current-sensitive RCCBs, type B and
type B+

Additional components

4/13

Used in

Leakage current measurement device


for fault locating and the optimum
selection of RCCBs
5SM2 RC units, type A

4/15

The freely selectable combination of RC IEC/EN 61009


units with miniature circuit breakers permits the flexible configuration of RCBO
combinations

--

5SU1 RCBOs, type AC and type A

4/18

The ideal protection combination for all IEC/EN 61009


electrical circuits due to the compact
device versions of RCCBs and miniature circuit breakers in a single device

Busbars

4/23

Busbars in 10 mm2 and 16 mm2 save


-space in the distribution board and time
during mounting.

5SM1 and 5SZ9 RCCB socket outlets 4/26

For retrofitting in existing installations

VDE 0664

Accessories

4/27

Locking devices, covers - everything


you need for mounting

--

5SV8 residual current monitors

Ch. 12

Monitoring of residual currents in elec- IEC 62020


trical plants with indication if a specified EN 62020
limit value is exceeded.

--

see chapter: "Monitoring Devices


> Monitoring Devices for Electrical
Values > Residual current monitors"

4/2

Siemens LV 10.1 2011

Siemens AG 2011
-25

(Typ AC) (Typ A)

Residual Current Protective Devices


5SM3 RCCBs, type AC and type A

Overview
RCCBs of type A are used in all systems up to 240/415 V AC.
They trip in the event of both sinusoidal AC residual currents and
pulsating DC residual currents.
RCCBs with a rated residual current of maximum 30 mA are
used for personnel, material and fire protection, as well as for
protection against direct contact. RCCBs with a rated residual
current of 10 mA are primarily used in areas that represent an increased risk for personnel.
Since DIN VDE 0100-410 came into effect in June 2007, all
socket outlet current circuits up to 20 A must now also be fitted
with residual current protective devices with a rated residual current of max. 30 mA. This also applies to outdoor electrical circuits up to 32 A for the connection of portable equipment.
Devices with a rated residual current of maximum 300 mA are
used as preventative fire protection in case of insulation faults.
RCCBs with a rated residual current of 100 mA are primarily
used outside Europe.
SIGRES
SIGRES RCCBs were developed for use in harsh ambient conditions, such as swimming baths as protection against chlorine
and ozone, in the agricultural sector (ammonia), on building
sites and in the chemical industry (nitrogen oxide, sulfur dioxide,
solvents), in the food processing industry (hydrogen sulfide) and
in unheated rooms (dampness). The patented active condensation protection requires a continuous power supply and bottom
infeed if the RCCB is switched off.

Benefits
Instantaneous RCCBs with the N connection on the left-hand
side enable simple bus mounting with standard pin busbars
with miniature circuit breakers installed on the right-hand side
Instantaneous RCCBs with the N connection on the right-hand
side can be bus-mounted with miniature circuit breakers using
a special pin busbar
Instantaneous devices have a surge current withstand capability with current waveform 8/20 s of > 1 kA, super resistant
of > 3 kA and selective of > 5 kA. This ensures safe operation
SIGRES has an extremely long service life due to patented active condensation protection and the same dimensions for the
quick and easy replacement of instantaneous RCCBs already
installed
Super resistant devices increase plant availability, as unnecessary tripping is prevented in systems with short-time
glitches
Selective RCCBs increase plant availability, as in the event of
a fault, a staggered tripping time enables the selective tripping of RCCBs connected in series
Auxiliary switches or remote controlled mechanisms are also
available as additional components
The operating handle and the test button can be locked by
means of a handle locking device.
Design
RCCB

By use in ambient conditions in acc. with product standard


EN 61008-1, the operation interval for pressing the test button
can be extended to 1x a year.

RCBO

Super resistant
Super resistant (short-time delayed) RCCBs meet the maximum
permissible break times for instantaneous devices. However, by
implementing a short-time delay they prevent unnecessary trippings, and thus plant faults, when pulse-shaped leakage currents occur - as is the case when capacitors are switched on.

Selection
criterion
RC unit

Equipment Circuit,
load current,
residual current

B
B+

Type
A

AC

Version
K

1+N

SIGRES 500 V

50- 400 Hz

System, equipment,
ambient conditions

Selective
Can be used as upstream group switch for selective tripping
contrary to a downstream, instantaneous or super resistant
RCCB.

Number of poles
3

Equipment

3+N

Note:
You will find further information on the subject of residual current
protective devices in the technology primer "Residual current
protective devices",
Order No.: E10003-E38-9T-B3011 and in the
Technology Manual under:
www.siemens.com/lowvoltage/manuals.

Rated residual current In


protection objective
residual current protection
In > 30mA
Additional
Trip conditions
Fire
protection
limited In
protection
In 30 mA
In 300 mA

Installation
regulation
VDE 0100-410
-530
-7xx
-482
VDS 3501

Rated current In

Equipment

Only with RCBOs with


MCB characteristic
C

Trip conditions acc.


to VDE 0100-410
Equipment

I2_15509a

Selection aid for finding the suitable residual current protective device

Siemens LV 10.1 2011

4/3

Siemens AG 2011

Residual Current Protective Devices

-25

(Typ AC) (Typ A)

5SM3 RCCBs, type AC and type A

Technical specifications
Instantaneous

SIGRES

Super resistant

Selective

Standards

IEC/EN 61008-1 (VDE 0664-10), IEC/EN 61008-2-1 (VDE 0664-11);


IEC/EN 61543 (VDE 0664-30)

Approvals

IEC 61008-1, IEC 61008-2-1; EN 61008-1, EN 61008-2-1

Surge current withstand capability


with current waveform 8/20 s
Acc. to DIN VDE 0432-2

kA

>1

Minimum operational voltage for test function operation

V AC

100

Insulation coordination
Overvoltage category

>3

>5

--

--

--

--

--

2.5 ... 50

3.0 ... 3.5

III

Terminal conductor cross-sections


For 2 MW

At In = 16 A, 25 A, 40 A
At In = 100 A, 125 A

mm2
mm2

1.0 ... 16
1.5 ... 50

For 2.5 MW

At In = 63 A, 80 A

mm2

1.5 ... 25

For 4 MW

At In = 25 A, 40 A, 63 A, 80 A
At In = 125 A

mm2
mm2

1.5 ... 25
2.5 ... 50

Up to In 80 A

Nm

2.5 ... 3.0

At In = 100 A, 125 A
Mains connection

Nm

3.0 ... 3.5

--

--

Top or bottom

Bottom

Top or bottom

Terminal tightening torque

Any

Mounting position
Degree of protection

Acc. to EN 60529
(VDE 0470-1)

IP20, if the distribution board is installed, with connected conductors

Touch protection

Acc. to EN 50274
(VDE 0660-514)

Finger and back-of-hand safe

Service life

Test cycle acc. to IEC/EN 61008 Switching


cycles

> 10000

Storage temperature

-40 ... +75

Ambient temperature

-25 ... +45,


marked with

Resistance to climate

Acc. to IEC 60068-2-30

CFC and silicone-free

4/4

Siemens LV 10.1 2011

-25

28 cycles (55 C; 95 % rel. air humidity)


Yes

Siemens AG 2011
-25

(Type AC)

Residual Current Protective Devices


5SM3 RCCBs, type AC

Applications
Personnel and fire protection
- In  30 mA: additional protection in case of direct contact
- In  300 mA: preventative fire protection in the case of
ground fault currents
Product standards: VE/NORM EN 61008;
VE/NORM E 8601

Un 230/400 V; 50 to 60 Hz; can be used in systems up to:


240/415 V AC
G type: at least 10 ms trip delayed.
High surge current withstand capability: > 3 kA.

Selection and ordering data


Rated residual Rated current
current

In

In

mA

Max.
permissible
short-circuit
series fuse

Width DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

RCCBs, type AC
instantaneous
2P; 125 ... 230 V AC, 50 ... 60 Hz
30

100

25
40
401)

63

X
X
X

5SM3 312-0LB
5SM3 314-0LB
5SM3 314-0LA

1
1
1

1 unit
1 unit
1 unit

006
006
006

0.230
0.230
0.280

X
X

5SM3 412-0LB
5SM3 414-0LB

1
1

1 unit
1 unit

006
006

0.230
0.230

X
X
X

5SM3 342-0LB
5SM3 344-0LB
5SM3 344-0LA

1
1
1

1 unit
1 unit
1 unit

006
006
006

0.515
0.515
0.515

63
631)

X
X

5SM3 346-0LB
5SM3 346-0LA

1
1

1 unit
1 unit

006
006

0.515
0.522

25
40
401)

X
X
X

5SM3 442-0LB
5SM3 444-0LB
5SM3 444-0LA

1
1
1

1 unit
1 unit
1 unit

006
006
006

0.515
0.515
0.515

63
631)

X
X

5SM3 446-0LB
5SM3 446-0LA

1
1

1 unit
1 unit

006
006

0.515
0.522

25
40
63

X
X
X

5SM3 642-0LB
5SM3 644-0LB
5SM3 646-0LB

1
1
1

1 unit
1 unit
1 unit

006
006
006

0.515
0.515
0.515

25
40

4P; 230 ... 400 V AC, 50 ... 60 Hz


30

100

300

25
40
401)

63

4P; 230 ... 400 V AC, 50 ... 60 Hz


30

125

5SM3 345-0

1 unit

006

0.300

100

125

125

5SM3 445-0

1 unit

006

0.533

300

125

5SM3 645-0

1 unit

006

0.300

500

125

5SM3 745-0

1 unit

006

0.522

RCCBs, type AC
short-time delayed
2P; 125 ... 230 V AC, 50 ... 60 Hz
30

401)

63

5SM3 314-0LA01

1 unit

006

0.280

100

X
X
X
X

5SM3 344-0LB01
5SM3 344-0LA01
5SM3 346-0LB01
5SM3 346-0LA01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

006
006
006
006

0.515
0.515
0.515
0.522

X
X
X
X

5SM3 444-0LB01
5SM3 444-0LA01
5SM3 446-0LB01
5SM3 446-0LA01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

006
006
006
006

0.515
0.515
0.515
0.522

4P; 230 ... 400 V AC, 50 ... 60 Hz

1)

30

40
401)
63
631)

100

40
401)
63
631)

Thermal overload protection according to VE/NORM E 8001 possible


up to rated current of the RCCB.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/5

Siemens AG 2011

Residual Current Protective Devices

-25

(Type A)

5SM3 RCCBs, type A

Selection and ordering data


Rated residual Rated current
current

In

In

mA

Max.
permissible
short-circuit
series fuse

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

RCCBs, type A
Instantaneous
1P+N; 125 ... 230 V AC; 50 ... 60 Hz
N connection, right
10

16

63

5SM3 111-6

1 unit

007

0.251

30

16
25
40

63

A
}
}

5SM3 311-6
5SM3 312-6
5SM3 314-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.248
0.248
0.247

63
80
100
125

100

2.5

A
B
B
B

5SM3 316-6
5SM3 317-6
5SM3 318-6KK
5SM3 315-6KK

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.328
0.330
0.272
0.269

25
40
63

63

100

2.5

B
B
B

5SM3 412-6
5SM3 414-6
5SM3 416-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.240
0.240
0.315

125

B
B
B

5SM3 417-6
5SM3 418-6KK
5SM3 415-6KK

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.324
0.272
0.273

63

100

2.5

A
A
B

5SM3 612-6
5SM3 614-6
5SM3 616-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.231
0.233
0.299

125

Up to 40 A
100

80
100
125
300
63 A and 80 A

25
40
63

80
100
125

5SM3 617-6

1 unit

007

0.320

B
B

5SM3 618-6KK
5SM3 615-6KK

1
1

1 unit
1 unit

007
007

0.256
0.255

N connection, left
10

16

63

5SM3 111-6KL

1 unit

007

0.280

30

16
25
40

63

C
B
B

5SM3 311-6KL
5SM3 312-6KL
5SM3 314-6KL

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.280
0.251
0.249

63

100

2.5

5SM3 316-6KL

1 unit

007

0.327

100

40
63

63
100

2
2.5

C
C

5SM3 414-6KL
5SM3 416-6KL

1
1

1 unit
1 unit

007
007

0.280
0.310

300

25
40
63

63

100

2.5

B
B
B

5SM3 612-6KL
5SM3 614-6KL
5SM3 616-6KL

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.234
0.235
0.313

}
}
}

5SM3 342-6
5SM3 344-6
5SM3 346-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.494
0.495
0.530

A
}

5SM3 347-6
5SM3 348-6

1
1

1 unit
1 unit

007
007

0.535
0.538

100 A and 125 A

3P+N; 230 ... 400 V AC; 50 ... 60 Hz


N connection, right
30

25
40
63

100

80
100

Up to 80 A

125

125

100

40
63
100
125

100

300

25
40
63

100

80
100
125
100 A and 125 A

500

25
40
63
100
125

5SM3 345-6

1 unit

007

0.564

A
A
}
B

5SM3 444-6
5SM3 446-6
5SM3 448-6
5SM3 445-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.474
0.488
0.538
0.538

A
A
A

5SM3 642-6
5SM3 644-6
5SM3 646-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.457
0.460
0.460

A
}
A

5SM3 647-6
5SM3 648-6
5SM3 645-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.462
0.538
0.540

B
A
A

5SM3 742-6
5SM3 744-6
5SM3 746-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.462
0.463
0.460

}
A

5SM3 748-6
5SM3 745-6

1
1

1 unit
1 unit

007
007

0.538
0.527

125

125
100

125

* You can order this quantity or a multiple thereof.

4/6

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices

-25

(Type A)

5SM3 RCCBs, type A


Rated residual Rated current
current

In

In

mA

Max.
permissible
short-circuit
series fuse

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

RCCBs, type A
Instantaneous
3P+N; 230 ... 400 V AC; 50 ... 60 Hz
N connection, left
30

25
40
63
80

100

B
}
B
B

5SM3 342-6KL
5SM3 344-6KL
5SM3 346-6KL
5SM3 347-6KL

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.494
0.495
0.527
0.532

300

25
40
63
80

100

B
B
B
B

5SM3 642-6KL
5SM3 644-6KL
5SM3 646-6KL
5SM3 647-6KL

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.458
0.463
0.464
0.454

500

63

100

5SM3 746-6KL

1 unit

007

0.460

63

5SM3 311-6KK13

1 unit

007

0.248

RCCBs, type A
Instantaneous, special versions
1P+N; 24 ... 125 V AC; 50 ... 60 Hz
30

16

3P+N; 500 V AC; 50 ... 60 Hz


30

25
40
63

63

B
B
B

5SM3 352-6
5SM3 354-6
5SM3 356-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.493
0.497
0.531

300

25
40
63

63

B
B
B

5SM3 652-6
5SM3 654-6
5SM3 656-6

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.459
0.461
0.464

B
B

5SM3 342-6KK03
5SM3 344-6KK03

1
1

1 unit
1 unit

007
007

0.515
0.510

3P+N; 230 ... 400 V AC; 50 ... 400 Hz


30

25
40

80

RCCBs, type A
SIGRES instantaneous
1P+N; 125 ... 230 V AC; 50 ... 60 Hz
30

25
40

63

B
C

5SM3 312-6KK12
5SM3 314-6KK12

1
1

1 unit
1 unit

007
007

0.248
0.251

63
80

100

2.5

B
B

5SM3 316-6KK12
5SM3 317-6KK12

1
1

1 unit
1 unit

007
007

0.330
0.331

3P+N; 230 ... 400 V AC; 50 ... 60 Hz


30

25
40
63
80

100

B
B
B
B

5SM3 342-6KK12
5SM3 344-6KK12
5SM3 346-6KK12
5SM3 347-6KK12

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.495
0.499
0.529
0.530

300

40
63

100

B
B

5SM3 644-6KK12
5SM3 646-6KK12

1
1

1 unit
1 unit

007
007

0.457
0.458

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/7

Siemens AG 2011

Residual Current Protective Devices

-25

(Type A)

5SM3 RCCBs, type A


Rated residual Rated current
current

In

In

mA

Max.
permissible
short-circuit
series fuse

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

RCCBs, type A
SIGRES, selective
3P+N; 230 ... 400 V AC; 50 ... 60 Hz
300

63

100

5SM3 646-8KK12

1 unit

007

0.506

5SM3 312-6KK01
5SM3 314-6KK01
5SM3 316-6KK01

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.250
0.247
0.329

RCCBs, type A
Super resistant
1P+N; 125 ... 230 V AC; 50 ... 60 Hz
30

25
40
63

63
100

2.5

B
B
B

300

63

100

2.5

5SM3 616-6KK01

1 unit

007

0.314

3P+N; 230 ... 400 V AC; 50 ... 60 Hz


30

25
40
63

100

B
B
B

5SM3 342-6KK01
5SM3 344-6KK01
5SM3 346-6KK01

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.515
0.520
0.519

300

40
63
80

100

B
B
B

5SM3 644-6KK01
5SM3 646-6KK01
5SM3 647-6KK01

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.492
0.490
0.498

RCCBs, type A
Selective
1P+N; 125 ... 230 V AC; 50 ... 60 Hz
100

63

100

2.5

5SM3 416-8

1 unit

007

0.325

300

40
63
80

63
100
100

2
2.5

B
A
B

5SM3 614-8
5SM3 616-8
5SM3 617-8

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.248
0.314
0.314

3P+N; 230 ... 400 V AC; 50 ... 60 Hz


N connection, right

Up to 80 A

100

40
63

100

B
B

5SM3 444-8
5SM3 446-8

1
1

1 unit
1 unit

007
007

0.513
0.531

300

40
63
100
125

100

A
A
B
C

5SM3 644-8
5SM3 646-8
5SM3 648-8
5SM3 645-8

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.507
0.505
0.538
0.546

500

125

125

5SM3 745-8

1 unit

007

0.531

1000

63

100

5SM3 846-8

1 unit

007

0.470

100

5SM3 646-8KL

1 unit

007

0.513

125

N connection, left
300

63

* You can order this quantity or a multiple thereof.

4/8

Siemens LV 10.1 2011

Siemens AG 2011

kHz

Residual Current Protective Devices

-25

(Type B/type B+)

SIQUENCE 5SM3 and 5SU1 universal currentsensitive RCCBs, type B and type B+

Overview

Benefits

Frequency converters, medical devices and UPS systems are


seeing increasing use in industry. Smooth DC residual currents
or currents with low residual ripple may occur in the event of
faults on these devices.
Type A residual current protective devices are unable to detect
these smooth DC residual currents. Furthermore, such smooth
DC residual currents make Type A devices increasingly insensitive to AC residual currents and pulsating DC residual currents.
If a fault occurs, there is therefore no tripping and the desired
protective function is no longer assured.
UC-sensitive residual current protective devices of Types B and
B+ have an additional transformer which is supplied with a control signal. This enables an evaluation of the change of the transformer's operating range caused by smooth DC residual currents, thus ensuring the desired protective function.
The residual current protective devices of type B are suitable for
use in three-phase current systems before input circuits with rectifiers. They are not intended for use in DC systems and in networks with operating frequencies other than 50 Hz or 60 Hz.

Universal current-sensitive residual current protective devices


detect not only AC residual currents and pulsating DC residual
currents, but also smooth DC residual currents, thus ensuring
the desired protective function with all types of residual current.
With Type B, the tripping characteristic is adapted to the increase of leakage currents at higher frequencies in systems
with capacitive impedances and results in increased operating safety
Type B+ versions offer enhanced preventative fire protection
and correspond to the prestandards DIN V VDE V 0664-110
and/or DIN V VDE V 0664-210 and VdS Directive 3501
The RCBO is a compact device for up to 125 A. It provides not
only personnel, property and fire protection but also overload
and short-circuit protection for cables. Wiring and mounting
outlay is reduced as a result
The RCBOs offer external remote tripping over terminals
Y1/Y2. This supports implementation of central OFF circuits.

The devices in this series are designed as residual current operated circuit breakers (RCCBs) up to 80 A and as residual current
circuit breakers with integral overcurrent protection (RCBOs) for
100 A or 125 A in Characteristics C or D.
Type B+ residual current protective devices also offer enhanced,
preventative fire protection. In these versions, the tripping value
is limited to a maximum of 420 mA up to 20 kHz.

Technical specifications

Standards

SIQUENCE, RCCBs
Type B and type B+
5SM3

SIQUENCE RCBOs
Type B and type B+
5SU1

IEC/EN 61008-1 (VDE 0664-10);


VDE 0664-100;
IEC/EN 61543 (VDE 0664-30);
IEC 62423

IEC/EN 61009-1 (VDE 0664-20);


VDE 0664-200;
IEC/EN 61543 (VDE 0664-30);
IEC 62423

And in addition for type B+:


DIN V VDE V 0664-110
Versions

1P+N

3P+N

4P

Tripping characteristic

--

--

C, D

kA
kA

>3
--

>3
>5

>3
>5

Minimum operational voltage for test


function operation

V AC

150

150

150

Rated voltages Un

V AC

230

400

400, 480

Rated frequency fn

Hz

50 ... 60

Rated currents In

16, 25, 40, 63

25, 40, 63, 80

100, 125

Rated residual currents In

mA

30, 300

30, 300, 500

30, 300

Rated switching capacity


Im
Icn

A
kA

800
--

Surge current withstand capability with


current waveform 8/20 s
acc. to DIN VDE 0432-2
Super resistant
Selective

Insulation coordination
Overvoltage category

-10

III

Conductor cross-sections
Solid and stranded
Finely stranded, with end sleeve

mm2
mm2

1.5 ... 25
1.5 ... 16

6 ... 50
6 ... 35

Terminal tightening torques for all devices

Nm

2.5 ... 3.0

3.0 ... 3.5

Mains connection

Either top or bottom

Mounting position

Any

Degree of protection
acc. to EN 60529 (VDE 0470-1)

IP20, if the distribution board is installed, with connected conductors

Touch protection
acc. to EN 50274 (VDE 0660-514)

Finger and back-of-hand safe

Siemens LV 10.1 2011

4/9

Siemens AG 2011

Residual Current Protective Devices

kHz

-25

(Type B/type B+)

SIQUENCE 5SM3 and 5SU1 universal currentsensitive RCCBs, type B and type B+
SIQUENCE, RCCBs
Type B and type B+
5SM3

SIQUENCE RCBOs
Type B and type B+
5SU1

> 10 000 switching cycles

Service life, electrical and mechanical;


(test cycle according to regulations)
Storage temperature

-40 ... +75

Ambient temperature

-25 ... +45,


marked with

-25

Resistance to climate acc. to IEC 60068-2-30

28 cycles (55 C; 95 % rel. air humidity)

CFC and silicone-free

Yes

I t characteristic curves, see Technology Manual under:


www.siemens.com/lowvoltage/manuals.

Selection and ordering data


Rated
residual
current

Rated current Max. permissible Mount- DT


short-circuit
ing
series fuse
width

In

In

mA

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

SIQUENCE RCCBs, type B


Super resistant
1P+N; 230 V AC; 50 ... 60 Hz
30

16
25
40
63

100

A
A
A
A

5SM3 321-4
5SM3 322-4
5SM3 324-4
5SM3 326-4

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.590
0.590
0.588
0.591

300

16
25
40
63

100

A
A
A
A

5SM3 621-4
5SM3 622-4
5SM3 624-4
5SM3 626-4

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.600
0.600
0.591
0.586

3P+N; 230 ... 400 V AC; 50 ... 60 Hz


30

25
40
63
80

100

D
D
D
B

5SM3 342-4
5SM3 344-4
5SM3 346-4
5SM3 347-4

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.582
0.578
0.581
0.587

300

25
40
63
80

100

D
D
A
B

5SM3 642-4
5SM3 644-4
5SM3 646-4
5SM3 647-4

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.592
0.581
0.576
0.585

500

63
80

100

B
B

5SM3 746-4
5SM3 747-4

1
1

1 unit
1 unit

015
015

0.575
0.575

SIQUENCE RCCBs, type B


Selective
3P+N; 230 ... 400 V AC; 50 ... 60 Hz
300

63
80

100

B
B

5SM3 646-5
5SM3 647-5

1
1

1 unit
1 unit

015
015

0.578
0.587

500

63
80

100

B
D

5SM3 746-5
5SM3 747-5

1
1

1 unit
1 unit

015
015

0.520
0.520

SIQUENCE RCCBs, type B+


Super resistant
1P+N; 230 V AC; 50 ... 60 Hz
30

16
25
40
63

100

C
C
C
C

5SM3 321-4KK14
5SM3 322-4KK14
5SM3 324-4KK14
5SM3 326-4KK14

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.587
0.600
0.600
0.600

300

16
25
40
63

100

C
C
C
C

5SM3 621-4KK14
5SM3 622-4KK14
5SM3 624-4KK14
5SM3 626-4KK14

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.600
0.600
0.600
0.600

* You can order this quantity or a multiple thereof.

4/10

Siemens LV 10.1 2011

Siemens AG 2011

kHz

Residual Current Protective Devices

-25

(Type B/type B+)

SIQUENCE 5SM3 and 5SU1 universal currentsensitive RCCBs, type B and type B+
Rated
residual
current

Rated current Max. permissible Mount- DT


short-circuit
ing
series fuse
width

In

In

mA

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

SIQUENCE RCCBs, type B+


Super resistant
3P+N; 230 ... 400 V AC; 50 ... 60 Hz
30

25
40
63
80

100

C
C
C
C

5SM3 342-4KK14
5SM3 344-4KK14
5SM3 346-4KK14
5SM3 347-4KK14

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.600
0.600
0.600
0.600

300

25
40
63
80

100

C
C
C
C

5SM3 642-4KK14
5SM3 644-4KK14
5SM3 646-4KK14
5SM3 647-4KK14

1
1
1
1

1 unit
1 unit
1 unit
1 unit

015
015
015
015

0.600
0.600
0.600
0.600

C
C

5SM3 646-5KK14
5SM3 647-5KK14

1
1

1 unit
1 unit

015
015

0.600
0.600

SIQUENCE RCCBs, type B+


Selective
3P+N; 230 ... 400 V AC; 50 ... 60 Hz
300

63
80

100

SIQUENCE RCBOs, Type B


Super resistant ,
rated switching capacity 10 kA
4P; 400 V AC; 50 ... 60 Hz
Characteristic C
30

100
125

11

B
B

5SU1 374-7AK81
5SU1 374-7AK82

1
1

1 unit
1 unit

017
017

2.067
2.053

300

100
125

11

B
B

5SU1 674-7AK81
5SU1 674-7AK82

1
1

1 unit
1 unit

017
017

2.069
2.088

Characteristic D
30

100

11

5SU1 374-8AK81

1 unit

017

2.084

300

100

11

5SU1 674-8AK81

1 unit

017

2.082

11

C
B

5SU1 674-7CK81
5SU1 674-7CK82

1
1

1 unit
1 unit

017
017

2.050
2.050

11

5SU1 674-7BK82

1 unit

017

2.082

11

5SU1 674-8BK81

1 unit

017

2.078

4P; 480 V AC; 50 ... 60 Hz


Characteristic C
300

100
125

SIQUENCE RCBOs, Type B


Selective ,
rated switching capacity 10 kA
4P; 400 V AC; 50 ... 60 Hz
Characteristic C
300

125

Characteristic D
300

100

SIQUENCE RCBOs, Type B+


Super resistant ,
rated switching capacity 10 kA
4P; 400 V AC; 50 ... 60 Hz
Characteristic C
30

100
125

11

C
C

5SU1 374-7DK81
5SU1 374-7DK82

1
1

1 unit
1 unit

017
017

2.067
2.053

300

100
125

11

C
D

5SU1 674-7DK81
5SU1 674-7DK82

1
1

1 unit
1 unit

017
017

2.069
2.088

Characteristic D
30

100

11

5SU1 374-8DK81

1 unit

017

2.084

300

100

11

5SU1 674-8DK81

1 unit

017

2.082

11

C
C

5SU1 674-7FK81
5SU1 674-7FK82

1
1

1 unit
1 unit

017
017

2.050
2.050

4P; 480 V AC; 50 ... 60 Hz


Characteristic C
300

100
125

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/11

Siemens AG 2011

Residual Current Protective Devices

kHz

-25

(Type B/type B+)

SIQUENCE 5SM3 and 5SU1 universal currentsensitive RCCBs, type B and type B+
Rated
residual
current

Rated current Max. permissible Mount- DT


short-circuit
ing
series fuse
width

In

In

mA

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10 000

MW

kg

SIQUENCE RCBOs, Type B+


Selective ,
rated switching capacity 10 kA
4P; 400 V AC; 50 ... 60 Hz
Characteristic C
300

125

11

5SU1 674-7EK82

1 unit

017

2.082

11

5SU1 674-8EK81

1 unit

017

2.078

Characteristic D
300

100

* You can order this quantity or a multiple thereof.

4/12

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices


Additional components

Overview

Benefits

Auxiliary switches (AS) signal the contact position of the


RCCB.
Remote controlled mechanisms are used for the remote ON/OFF
switching of RCCBs. They also enable local manual switching.
A blocking function permits maintenance work. A tripped RCCB
must be acknowledged prior to switching back on.
The leakage current measurement device detects the leakage
currents - like the circuit breaker - thus providing a direct statement as to the current loading of the RCCB. It is used to measure
leakage currents up to 300 mA. This requires a voltmeter with an
internal resistance > 1 M/V and a measuring range for AC voltages of Ueff = 1 mV to 2 V. For the fault-free operation of an
RCCB, the measured leakage current should be no greater than
1/3 of the rated residual current.

Using captive brackets, the remote-controlled operating


mechanism can be attached (or retroffitted) to the right-hand
side of the basic device without the need for tools
Bus systems, such as instabus KNX, AS-Interface bus or
PROFIBUS, can be integrated in the communication over
binary inputs
The leakage current measurement device enables the systematic selection of the rated residual current, thus preventing
the inadvertent tripping of RCCBs.

Technical specifications
Auxiliary switches (AS)
5SW3 30.
Standards

IEC/EN 60947-5-1

Approvals

DIN VDE 0660-200

Auxiliary switches (AS)


5SW3 330

Terminals
Conductor cross-section

mm2

0.75 ... 2.5

Tightening torques

Nm

0.6 ... 0.8

Short-circuit protection

B6 or C6 or gL/gG 6 A fuse

Min. contact load

50 mA/24 V

Max. contact load


230 V AC, AC-12

230 V AC, AC-14

3.6

--

220 V DC, DC-12

0.5

Siemens LV 10.1 2011

4/13

Siemens AG 2011

Residual Current Protective Devices


Additional components

Selection and ordering data


Version

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW
Auxiliary switches (AS)
for 5SM3 RCCBs up to 80 A
1 NO + 1 NC

0.5

5SW3 300

1 1/10 units

008

0.050

2 NC

0.5

5SW3 301

1 1/10 units

008

0.049

2 NO

0.5

5SW3 302

1 1/10 units

008

0.050

0.5

5SW3 330

1 unit

008

0.041

3.5

5ST3 051

1 unit

027

0.449

5SM1 930-0

1 unit

008

0.489

Auxiliary switches (AS)


for 5SM3 RCCBs up to 100 ... 125 A, 3P+N
1 NO + 1 NC

Remote controlled mechanisms (RC)


for 5SM3 RCCBs up to 80 A
Rated voltage Un = 230 V AC

Leakage current measurement devices


Rated voltage Un = 500 V AC;
50 ... 60 Hz; 4P
Rated residual current In = 0 ... 300 mA
Rated current In = 63 A.

I201_13711a

Covers for connection terminals


For residual current operated circuit breakers
up to 80 A, sealable (2 units in plastic bag)
2

5SW3 010

1 1/50 units

008

0.008

2.5

5SW3 011

1 1/50 units

008

0.008

5SW3 008

1 1/50 units

008

0.008

5SW3 303

10 units

008

0.009

5ST3 802

1 unit

027

0.031

5SW3 312

1 set

008

0.028

Locking devices
For RCCBs up to 80 A, sealable and lockable
4.5 mm lock hasp diameter

Padlocks
For 5SW3 303 locking device

Locking devices with padlock


Comprising 5SW3 303 locking device and
5ST3 802 padlock

* You can order this quantity or a multiple thereof.

4/14

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices

-25

(Type A)

5SM2 RC units, type A

Overview

Benefits
Our wide variety of RC unit types and comprehensive range of
miniature circuit breakers offer a huge spectrum of combinations for all applications
All devices have surge current withstand capability of more
than 1 kA, thus ensuring safe and reliable operation
All additional components for miniature circuit breakers can
be retrofitted on the right-hand side
All 100 A and 125 A RC units offer external remote tripping
over terminals Y1/Y2. This supports implementation of central
OFF circuits.
Both components can be simply plugged into each other and
secured with captive metal brackets - no tools required. This
saves considerable time when mounting.

RC units of type A can be used in all systems up to


240/415 V AC. They trip in the event of both sinusoidal AC fault
currents and pulsating residual currents.
RCCBs with a rated residual current of maximum 30 mA are
used for personnel, material and fire protection, as well as for
protection against direct contact.
Devices with a rated residual current of maximum 300 mA are
used as preventative fire protection in case of insulation faults.
RC units are combined with miniature circuit breakers with characteristics A, B, C and D, provided that these are available in the
MCB range. The two components are simply plugged together
without the need for any tools.
They then form a combination of RCCB and MCB for personnel,
fire and line protection.
Super resistant
Super resistant (short-time delayed) RC units satisfy the maximum permissible break times for instantaneous devices. However, by implementing a short-time delay they prevent unnecessary trippings, and thus plant faults, when pulse-shaped
leakage currents occur - as is the case when capacitors are
switched on.
Selective
Can be used as upstream group switch for selective tripping
contrary to a downstream, instantaneous or super resistant
RCCB.
The dimensioning of the rated residual current depends on the
size of the plant.

Technical specifications
5SM2
Standards

IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21),


IEC/EN 61543 (VDE 0664-30)

Approvals

EN 61009-1, EN 61009-2-1; IEC 61009-1, IEC 61009-2-1

Surge current withstand capability


With current waveform 8/20 s
Acc. to DIN VDE 0432-2
Instantaneous
Super resistant
Selective

kA
kA
kA

>1
>3
>5

Minimum operational voltage for test function operation


Up to In = 63 A, 2 and 3-pole
Up to In = 63 A, 4-pole
At In = 80 ... 100 A

V AC
V AC
V AC

195
100
100

Rated voltage Un

V AC

230 ... 400

Rated frequency fn

Hz

50 ... 60

Rated currents In

0.3 ... 16; 0.3 ... 40; 0.3 ... 63; 80 ... 100

Rated residual currents In

mA

10, 30, 100, 300, 500, 1000

Insulation coordination
Overvoltage category

III

Terminal conductor cross-sections


Up to In 63 A
At In = 80 ... 100 A

mm2
mm2

1.5 ... 25
6.0 ... 50

Terminal tightening torque

Nm

2.5 ... 3.0


Either top or bottom

Mains connection

Any

Mounting position
Degree of protection

Acc. to EN 60529 (VDE 0470-1)

IP20, if the distribution board is installed, with connected conductors

Touch protection

Acc. to EN 50274 (VDE 0660-514)

Finger and back-of-hand safe

Service life

Test cycle acc. to DIN/EN 61009

> 10 000 switching cycles

Storage temperature

-40 ... +75

Ambient temperature

-25 ... +45,


marked with

Resistance to climate
CFC and silicone-free

Acc. to IEC 60068-2-30

-25

28 cycles (55 C; 95 % rel. air humidity)


Yes

Siemens LV 10.1 2011

4/15

Siemens AG 2011

Residual Current Protective Devices

-25

(Type A)

5SM2 RC units, type A

Selection and ordering data


Rated residual Rated current
current

In

In

mA

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

RC units, type A
Instantaneous
For 5SY miniature circuit breakers,
not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
2P, 230 ... 400 V AC, 50 ... 60 Hz
10

0.3 ... 16

5SM2 121-6

1 unit

007

0.207

30
300

0.3 ... 40

}
A

5SM2 322-6
5SM2 622-6

1
1

1 unit
1 unit

007
007

0.209
0.199

30
100
300
500

0.3 ... 63

A
B
B
B

5SM2 325-6
5SM2 425-6
5SM2 625-6
5SM2 725-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.215
0.211
0.203
0.198

A
A

5SM2 332-6
5SM2 632-6

1
1

1 unit
1 unit

007
007

0.314
0.295

B
B
B
B

5SM2 335-6
5SM2 435-6
5SM2 635-6
5SM2 735-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.359
0.327
0.298
0.322

}
}

5SM2 342-6
5SM2 642-6

1
1

1 unit
1 unit

007
007

0.337
0.326

A
B
A
A

5SM2 345-6
5SM2 445-6
5SM2 645-6
5SM2 745-6

1
1
1
1

1 unit
1 unit
1 unit
1 unit

007
007
007
007

0.397
0.357
0.328
0.326

3.5

B
B

5SM2 327-6
5SM2 627-6

1
1

1 unit
1 unit

007
007

0.529
0.458

B
A

5SM2 347-6
5SM2 647-6

1
1

1 unit
1 unit

007
007

0.934
0.682

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
3P; 230 ... 400 V AC; 50 ... 60 Hz
30
300

0.3 ... 40

30
100
300
500

0.3 ... 63

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
4P, 230 ... 400 V AC, 50 ... 60 Hz
30
300

0.3 ... 40

30
100
300
500

0.3 ... 63

For 5SP4 miniature circuit breakers


(characteristics B and C)
2P, 125 ... 230 V AC, 50 ... 60 Hz
30
300

80 ... 100

For 5SP4 miniature circuit breakers


(characteristics B and C)
4P, 230 ... 400 V AC, 50 ... 60 Hz
30
300

80 ... 100

* You can order this quantity or a multiple thereof.

4/16

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices

-25

(Type A)

5SM2 RC units, type A


Rated residual Rated current
current
In

In

mA

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

RC units, type A
Super resistant
For 5SY miniature circuit breakers,
not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
2P, 230 ... 400 V AC, 50 ... 60 Hz
30

0.3 ... 40

30

0.3 ... 63

5SM2 322-6KK01

1 unit

007

0.215

5SM2 325-6KK01

1 unit

007

0.214

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
3P; 230 ... 400 V AC; 50 ... 60 Hz
30

0.3 ... 40

30

0.3 ... 63

5SM2 332-6KK01

1 unit

007

0.365

5SM2 335-6KK01

1 unit

007

0.365

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
4P, 230 ... 400 V AC, 50 ... 60 Hz
30

0.3 ... 40

30

0.3 ... 63

5SM2 342-6KK01

1 unit

007

0.390

5SM2 345-6KK01

1 unit

007

0.388

5SM2 622-8

1 unit

007

0.210

5SM2 625-8

1 unit

007

0.210

RC units, type A
Selective
For 5SY miniature circuit breakers,
not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
2P, 230 ... 400 V AC, 50 ... 60 Hz
300

0.3 ... 40

300

0.3 ... 63

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
3P; 230 ... 400 V AC; 50 ... 60 Hz
1000

0.3 ... 40

5SM2 832-8

1 unit

007

0.301

300
500
1000

0.3 ... 63

B
B
D

5SM2 635-8
5SM2 735-8
5SM2 835-8

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.341
0.323
0.304

A
A
A

5SM2 645-8
5SM2 745-8
5SM2 845-8

1
1
1

1 unit
1 unit
1 unit

007
007
007

0.373
0.333
0.333

3.5

5SM2 627-8

1 unit

007

0.519

A
A

5SM2 647-8
5SM2 847-8

1
1

1 unit
1 unit

007
007

0.838
0.706

For 5SY miniature circuit breakers,


not suitable for use with 5SY5, 5SY8 and 5SY6 0. .,
4P, 230 ... 400 V AC, 50 ... 60 Hz
300
500
1000

0.3 ... 63

For 5SP4 miniature circuit breakers


(characteristics B and C)
2P, 125 ... 230 V AC, 50 ... 60 Hz
300

80 ... 100

For 5SP4 miniature circuit breakers


(characteristics B and C)
4P, 230 ... 400 V AC, 50 ... 60 Hz
300
1000

80 ... 100

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/17

Siemens AG 2011

Residual Current Protective Devices

-25

(Type AC) (Type A)

5SU1 RCBOs, type AC and type A

Overview

RCBOs are a combination of an RCCB and a miniature circuit


breaker in a compact design for personnel, fire and line protection. For personnel and fire protection, the residual current part
of the type A trips in the event of sinusoidal AC residual currents
and pulsating DC residual currents.
RCBOs with a rated residual current of maximum 30 mA are
used for personnel, material and fire protection, as well as for
protection against direct contact. RCBOs with a rated residual
current of 10 mA are primarily used in areas that represent an increased risk for personnel and the outdoor installations of residential buildings.
Devices with a rated residual current of maximum 300 mA are
used as preventative fire protection in case of insulation faults.
The MCB part of the RCBO protects lines against overload and
short circuits and is available in characteristics B and C.
Since DIN VDE 0100-410 came into effect in June 2007, all
socket outlet current circuits up to 20 A must now also be fitted
with residual current protective devices with a rated residual current of max. 30 mA. This also applies to outdoor electrical circuits up to 32 A for the connection of portable equipment.

In order to implement this protection, we recommend the national use of RCBOs with 30 mA.
Assignment to each individual branch circuit helps prevent the
unwanted tripping of fault-free circuits induced by the accumulation of operation-related leakage currents or by transient current pulses during switching operations.
Additional components of the 5SY miniature circuit breakers can
be mounted at the side and carry out additional functions.
For further details on additional components, please refer to the
chapter "Miniature Circuit Breakers".
RCBOs comprise one part for fault-current detection and one
part for overcurrent detection. They are equipped with a delayed
overload/time-dependent thermal release (thermal bimetal) for
low overcurrents and with an instantaneous electromagnetic release for higher overload and short-circuit currents.
The special contact materials used guarantee a long service life
and offer a high degree of protection against contact welding.

Benefits

For all versions


Clear and visible conductor connection in front of the busbar
facilitates controls
Large and easily accessible wiring space enables easy insertion of conductor in the terminals.
The surge current withstand capability of > 1 kA ensures safe
and reliable operation.
All additional components for miniature circuit breakers can
be retrofitted on the right-hand side.
For all 10 kA versions up to 40 A
Integrated movable terminal covers located at the cable entries ensure the terminals are fully insulated when the screws
are tightened. The effective touch protection when grasping
the device considerably exceeds the requirements of BGV A3.
The RCBOs can be quickly and easily removed from the
assembly by hand if connections need to be changed. This
saves time if parts need to be replaced because the busbars
no longer need to be freed from the adjacent miniature circuit
breakers.

4/18

Siemens LV 10.1 2011

For all 125 A versions


The RCBOs offer external remote tripping over terminals
Y1/Y2. This supports implementation of central OFF circuits.

Siemens AG 2011

-25

(Type AC) (Type A)

Residual Current Protective Devices


5SU1 RCBOs, type AC and type A

Technical specifications
Up to 40 A

125 A

IEC/EN 61009-1 (VDE 0664-20), IEC/EN 61009-2-1 (VDE 0664-21)


IEC/EN 61543; VDE 0664-30

Standards

IEC 61009-1, IEC 61009-2-1; EN 61009-1, EN 61009-2-1

Approvals
Rated voltages Un

V AC

125 ... 230

Rated frequency fn

Hz

50 ... 60

Rated currents In

6, 8, 10, 13, 16, 20, 25, 32, 40

125

Rated residual currents In

mA

10, 30, 300

30, 300, 1000

Rated switching capacity

kA

6, 10

10

--

kA
kA
kA

>1
>3
>5

--

V AC

100

Energy limitation class

400

Surge current withstand capability


With current waveform 8/20 s
Instantaneous
Super resistant
Selective

Acc. to DIN VDE 0432-2

Minimum voltage for operation of the test equipment


Insulation coordination
Overvoltage category

III

Terminal conductor cross-sections


Solid and stranded
Finely stranded with end sleeve

mm2
mm2

0.75 ... 35
0.75 ... 25

6 ... 50
6 ... 35

Terminal tightening torque

Nm

2.5 ... 3.0

3.0 ... 3.5

Top or bottom

Mains connection

Any

Mounting position
Degree of protection

Acc. to EN 60529
(VDE 0470-1)

IP20, if the distribution board is installed, with connected conductors

Touch protection

Acc. to EN 50274
(VDE 0660-514)

Finger and back-of-hand safe

Service life

Test cycle acc. to


IEC/EN 61009

Switching
cycles

> 10000

Storage temperature

-40 ... +75

Ambient temperature

-25 ... +45,


marked with

Acc. to IEC 60068-2-30

Resistance to climate

-25

28 cycles (55 C; 95 % rel. air humidity)


Yes

CFC and silicone-free

Selection and ordering data


Tripping characteristic B
Rated
Rated Mount- DT Order No.
residual current ing
current
width
In
In
mA

Tripping characteristic C

Price PG
per PU

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

RCBOs, type AC
RCBOs, type AC
Instantaneous
1P+N; 230 V AC; 50 ... 60 Hz
6 000
3
30

6
8
10
13
16

20
25
32
40
300

6
10
13
16
20
25
32
40

X
X
X
X

5SU1 356-0KK06
-5SU1 356-0KK10
5SU1 356-0KK13
5SU1 356-0KK16

010 X
X
010 X
010 X
010 X

5SU1 356-1KK06
5SU1 356-1KK08
5SU1 356-1KK10
5SU1 356-1KK13
5SU1 356-1KK16

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

010
010
010
010
010

0.279
0.278
0.279
0.283
0.279

X
X
X
X

5SU1 356-0KK20
5SU1 356-0KK25
5SU1 356-0KK32
5SU1 356-0KK40

010
010
010
010

X
X
X
X

5SU1 356-1KK20
5SU1 356-1KK25
5SU1 356-1KK32
5SU1 356-1KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.289
0.293
0.296
0.295

X
X
X
X

5SU1 656-0KK06
5SU1 656-0KK10
5SU1 656-0KK13
5SU1 656-0KK16

010
010
010
010

X
X
X
X

5SU1 656-1KK06
5SU1 656-1KK10
5SU1 656-1KK13
5SU1 656-1KK16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.279
0.278
0.283
0.280

X
X
X
X

5SU1 656-0KK20
5SU1 656-0KK25
5SU1 656-0KK32
5SU1 656-0KK40

010
010
010
010

X
X
X
X

5SU1 656-1KK20
5SU1 656-1KK25
5SU1 656-1KK32
5SU1 656-1KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.293
0.294
0.292
0.290

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/19

Siemens AG 2011

Residual Current Protective Devices

-25

(Type AC) (Type A)

5SU1 RCBOs, type AC and type A


Tripping characteristic B
Rated
Rated Mount- DT Order No.
residual current ing
current
width
In
In

mA

Tripping characteristic C

Price PG
per PU

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

RCBOs, type AC
Instantaneous
1P+N; 230 V AC; 50 ... 60 Hz
10 000
3
30

6
8
10
13
16

20
25
32
40
100

6
10
13
16

X
X
X
X

5SU1 354-0KK06
-5SU1 354-0KK10
5SU1 354-0KK13
5SU1 354-0KK16

010 X
X
010 X
010 X
010 X

5SU1 354-1KK06
5SU1 354-1KK08
5SU1 354-1KK10
5SU1 354-1KK13
5SU1 354-1KK16

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

010
010
010
010
010

0.260
0.260
0.260
0.260
0.260

X
X
X
X

5SU1 354-0KK20
5SU1 354-0KK25
5SU1 354-0KK32
5SU1 354-0KK40

010
010
010
010

X
X
X
X

5SU1 354-1KK20
5SU1 354-1KK25
5SU1 354-1KK32
5SU1 354-1KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.260
0.260
0.260
0.260

-----

X
X
X
X

5SU1 454-1KK06
5SU1 454-1KK10
5SU1 454-1KK13
5SU1 454-1KK16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.260
0.260
0.260
0.260

-----

X
X
X
X

5SU1 454-1KK20
5SU1 454-1KK25
5SU1 454-1KK32
5SU1 454-1KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.260
0.260
0.260
0.260

20
25
32
40
300

6
10
13
16

20
25
32
40

X
X
X
X

5SU1 654-0KK06
5SU1 654-0KK10
5SU1 654-0KK13
5SU1 654-0KK16

010
010
010
010

X
X
X
X

5SU1 654-1KK06
5SU1 654-1KK10
5SU1 654-1KK13
5SU1 654-1KK16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.260
0.260
0.260
0.260

X
X
X
X

5SU1 654-0KK20
5SU1 654-0KK25
5SU1 654-0KK32
5SU1 654-0KK40

010
010
010
010

X
X
X
X

5SU1 654-1KK20
5SU1 654-1KK25
5SU1 654-1KK32
5SU1 654-1KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.260
0.260
0.260
0.260

X
X
X

5SU1 354-0LB10
5SU1 354-0LB13
5SU1 354-0LB16

010 X
010 X
010 X

5SU1 354-1LB10
5SU1 354-1LB13
5SU1 354-1LB16

1
1
1

1 unit 010
1 unit 010
1 unit 010

0.260
0.260
0.260

X
X
X
X

5SU1 354-0LB20
5SU1 354-0LB25
5SU1 354-0LB32
5SU1 354-0LB40

010
010
010
010

X
X
X
X

5SU1 354-1LB20
5SU1 354-1LB25
5SU1 354-1LB32
5SU1 354-1LB40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

010
010
010
010

0.260
0.260
0.260
0.260

A
B
}

5SU1 356-6KK06
-5SU1 356-6KK10
5SU1 356-6KK13
5SU1 356-6KK16

011 A
B
011 }
011 A
011 }

5SU1 356-7KK06
5SU1 356-7KK08
5SU1 356-7KK10
5SU1 356-7KK13
5SU1 356-7KK16

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

011
011
011
011
011

0.279
0.278
0.279
0.283
0.279

B
B
B
B

5SU1 356-6KK20
5SU1 356-6KK25
5SU1 356-6KK32
5SU1 356-6KK40

011
011
011
011

B
A
B
B

5SU1 356-7KK20
5SU1 356-7KK25
5SU1 356-7KK32
5SU1 356-7KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.289
0.293
0.296
0.295

B
B
B
B

5SU1 656-6KK06
5SU1 656-6KK10
5SU1 656-6KK13
5SU1 656-6KK16

011
011
011
011

B
A
B
A

5SU1 656-7KK06
5SU1 656-7KK10
5SU1 656-7KK13
5SU1 656-7KK16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.279
0.278
0.283
0.280

B
B
B
B

5SU1 656-6KK20
5SU1 656-6KK25
5SU1 656-6KK32
5SU1 656-6KK40

011
011
011
011

B
B
B
B

5SU1 656-7KK20
5SU1 656-7KK25
5SU1 656-7KK32
5SU1 656-7KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.293
0.294
0.292
0.290

RCBOs, type AC
short-time delayed
2P (1P+N); AC 230 V;
50 ... 60 Hz
10 000
3
30

10
13
16

20
25
32
40

RCBOs, type A
RCBOs, type A
Instantaneous
1P+N; 230 V AC; 50 ... 60 Hz
6 000
3
30

6
8
10
13
16

20
25
32
40
300

6
10
13
16
20
25
32
40

* You can order this quantity or a multiple thereof.

4/20

Siemens LV 10.1 2011

Siemens AG 2011

-25

(Type AC) (Type A)

Residual Current Protective Devices


5SU1 RCBOs, type AC and type A
Tripping characteristic B

Rated
Rated Mount- DT Order No.
residual current ing
current
width
In
In
mA

Tripping characteristic C

Price PG
per PU

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

RCBOs, type A
Instantaneous
1P+N; 230 V AC; 50 ... 60 Hz
10 000
3
10

6
10
13
16

B
B
B
B

5SU1 154-6KK06
5SU1 154-6KK10
5SU1 154-6KK13
5SU1 154-6KK16

011
011
011
011

B
B
B
}

5SU1 154-7KK06
5SU1 154-7KK10
5SU1 154-7KK13
5SU1 154-7KK16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.288
0.287
0.290
0.284

30

6
8
10
13
16

B
B
B
}

5SU1 354-6KK06
-5SU1 354-6KK10
5SU1 354-6KK13
5SU1 354-6KK16

011 }
B
011 }
011 B
011 }

5SU1 354-7KK06
5SU1 354-7KK08
5SU1 354-7KK10
5SU1 354-7KK13
5SU1 354-7KK16

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

011
011
011
011
011

0.283
0.260
0.283
0.288
0.282

B
B
B
B

5SU1 354-6KK20
5SU1 354-6KK25
5SU1 354-6KK32
5SU1 354-6KK40

011
011
011
011

B
B
B
B

5SU1 354-7KK20
5SU1 354-7KK25
5SU1 354-7KK32
5SU1 354-7KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.289
0.288
0.292
0.286

B
B
B
B

5SU1 654-6KK06
5SU1 654-6KK10
5SU1 654-6KK13
5SU1 654-6KK16

011
011
011
011

B
B
B
B

5SU1 654-7KK06
5SU1 654-7KK10
5SU1 654-7KK13
5SU1 654-7KK16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.284
0.282
0.288
0.281

B
B
B
B

5SU1 654-6KK20
5SU1 654-6KK25
5SU1 654-6KK32
5SU1 654-6KK40

011
011
011
011

B
B
B
B

5SU1 654-7KK20
5SU1 654-7KK25
5SU1 654-7KK32
5SU1 654-7KK40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.285
0.285
0.287
0.289

B
}
B
}

5SU1 324-6FA06
5SU1 324-6FA10
5SU1 324-6FA13
5SU1 324-6FA16

011
011
011
011

B
}
B
}

5SU1 324-7FA06
5SU1 324-7FA10
5SU1 324-7FA13
5SU1 324-7FA16

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.421
0.414
0.423
0.414

B
B
B
B

5SU1 324-6FA20
5SU1 324-6FA25
5SU1 324-6FA32
5SU1 324-6FA40

011
011
011
011

B
B
B
B

5SU1 324-7FA20
5SU1 324-7FA25
5SU1 324-7FA32
5SU1 324-7FA40

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.427
0.432
0.427
0.427

5SU1 324-6KK82

011 B

5SU1 324-7KK82

1 unit 011

1.212

5SU1 624-6KK82

011 B

5SU1 624-7KK82

1 unit 011

0.930

5SU1 344-6KK82

011 B

5SU1 344-7KK82

1 unit 011

2.024

5SU1 644-6KK82

011 B

5SU1 644-7KK82

1 unit 011

2.025

20
25
32
40
300

6
10
13
16

20
25
32
40
2P; 230 V AC; 50 ... 60 Hz
10 000
3
30

6
10
13
16

20
25
32
40
2P; 400 V AC; 50 ... 60 Hz
10 000
30

125

300

125

6.5

4P; 400 V AC; 50 ... 60 Hz


10 000
30

125

300

125

11

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/21

Siemens AG 2011

Residual Current Protective Devices

-25

(Type AC) (Type A)

5SU1 RCBOs, type AC and type A


Tripping characteristic B
Rated
Rated Mount- DT Order No.
residual current ing
current
width
In
In

mA

Tripping characteristic C

Price PG
per PU

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

RCBOs, type A
Super resistant
1P+N; 230 V AC; 50 ... 60 Hz
10 000
3
30

10
16
20
25

-----

B
B
C
C

5SU1 354-7VK10
5SU1 354-7VK16
5SU1 354-7VK20
5SU1 354-7VK25

1
1
1
1

1 unit
1 unit
1 unit
1 unit

011
011
011
011

0.293
0.292
0.296
0.296

RCBOs, type A
Selective
2P; 400 V AC; 50 ... 60 Hz
10 000
300

125

6.5

5SU1 624-6WK82

011 B

5SU1 624-7WK82

1 unit 011

0.930

5SU1 644-6WK82

011 B

5SU1 644-7WK82

1 unit 011

2.018

4P; 400 V AC; 50 ... 60 Hz


10 000
300

125

11

Version

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Handle couplers for additional components


For mounting the additional components auxiliary switches, fault }
signal contacts, shunt trips and undervoltage releases onto 5SU1
RCBOs, you require a handle coupler (1 set = 5 units).

5ST3 805-1

1 set 027

0.006

Note:
The same additional components are used for RCBOs as for miniature circuit breakers. See chapter "Miniature Circuit Breakers".
5ST3

or

AS

or

FC

or

AS
FC

AS
FC

AS
FC

FC
AS

AS
FC

FC
AS

AS
FC

FC
AS

5SU1

or

or

I2_13658b

or

RCBO

RCBO:
RC:
UR:
ST:
AS:
FC:

RC

Residual current operated


circuit breaker
Remote controlled
mechanism
Undervoltage release
Shunt trip
Auxiliary switch
Fault signal contact

ST

AS

FC

or

UR

AS

AS
FC

AS
FC

or

FC

or

AS
FC

AS
FC

* You can order this quantity or a multiple thereof.

4/22

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices


Busbars

Overview
4-pole 5SM3 RCCBs are bus-mounted either together or in combination with miniature circuit breakers. RCCBs with an N wire
connection on the left-hand side facilitate installation because
standard busbars are used, as those used for mounting miniature circuit breakers.
2

Busbars in 10 mm and 16 mm versions are available.


The extremely flexible 5ST3 6 busbar system with fixed lengths
enables installation in any length as the busbars can be overlapped.

No further need for time-consuming tasks, such as cutting, cutting to length, deburring, cleaning of cut surfaces and mounting
of end caps.
Any free pins on the busbars can be made safe by covering with
touch protection.
If several RCBOs are bus-mounted together, this is implemented
with two-phase busbars, which are used as 1+N busbars.

Benefits
Connection of miniature circuit breakers to 4-pole RCCBs with
N connection right and three-phase busbar, using busbar
specially designed for this application. No cutting or end caps
required.

Connection of miniature circuit breakers to 4-pole RCCBs with


N connection left, with three-phase busbar that can be cut. No
additional items to be stored and busbars that are always
available.

Connection of 1P+N RCBOs with two-phase busbar. No cutting or end caps required.

Bus-mounting of RCCBs on busbar (3-phase +N) that can be


cut. A proven and frequently used application.

Siemens LV 10.1 2011

4/23

Siemens AG 2011

Residual Current Protective Devices


Busbars

Technical specifications
5ST3, 5ST2

Standards

EN 60439-1 (VDE 0660-500): 2005-01

Busbar material

SF-Cu F 24

Partition material

Plastic, Cycoloy 3600


Heat-resistant over 90 C
flame-retardant and
self-extinguishing,
dioxin and halogen-free
V AC 400

Rated operational voltage Ue


Rated current In
Cross-section 10 mm2
Cross-section 16 mm2

A
A

63
80

Rated impulse withstand voltage Uimp

kV

Test pulse voltage (1.2/50)

kV

6.2

Rated conditional short-circuit current Icc

kA

25

Resistance to climate
Constant atmosphere
Humid heat

Acc. to DIN 50015


Acc. to IEC 68-2-30

23/83; 40/92; 55/20


28 cycles

Insulation coordination

Acc. to IEC 664 (VDE 0110-1)

Overvoltage category
Pollution degree

III
2

Maximum busbar current IS/phase


Infeed at the start of the busbar
- Cross-section 10 mm2
- Cross-section 16 mm2

A
A

63
80

Infeed at the center of the busbar


- Cross-section 10 mm2
- Cross-section 16 mm2

A
A

100
130

Infeed at the start or end of the busbar

Infeed along the busbar or midpoint infeed


3

3
I201_13754a

I201_13755

The sum of the output current per branch (1, 2, 3 ... n) must not be greater
than the max. busbar current IS/phase.

Selection and ordering data


Version

Pin
spacing

Length

MW

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

5ST3 6 busbar systems,


fixed lengths, cannot be cut, fully insulated
For 1 FI 4P, N connection right, and 8 LS 1P
3-phase 10 mm2
3-phase 16 mm2

1
1

210
210

A
A

5ST3 624
5ST3 654

1 10 units
1 10 units

027
027

0.077
0.108

210
210

A
A

5ST3 608
5ST3 638

1 10 units
1 10 units

027
027

0.063
0.089

5ST3 717

1 25 units

027

0.115

A
}

5ST3 734
5ST3 704

1
1

027
027

0.070
0.092

For 6 RCBOs 1P+N together


2-phase 10 mm2
2-phase 16 mm2
5ST3 7 busbar systems,
12 MW, can be cut to length, with end caps
For 1 FI 4P, N connection right, and 8 LS 1P
3-phase 16 mm2
For 6 RCBOs 1P+N
2-phase 10 mm2
2-phase 16 mm2

1
1

216
216

1 unit
1 unit

* You can order this quantity or a multiple thereof.

4/24

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices


Busbars
Version

Pin
spacing

Length

MW

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

5ST3 7 busbar systems, with end caps,


can be cut to length, with touch protection
For RCBO 1P+N and MCB 2P
4-phase 10 mm2
4-phase 16 mm2

1
1

1008
1008

A
A

5ST3 770-2
5ST3 770-3

1 10 units
1 10 units

027
027

0.400
0.550

288
288

A
A

5ST3 770-4
5ST3 770-5

1 10 units
1 10 units

027
027

0.100
0.160

}
A

5ST3 750
5ST3 718

1 10 units
1 10 units

027
027

0.001
0.001

5ST3 655

1 10 units

027

0.003

5ST2 145

1 unit

027

0.145

5ST2 156

1 10 units

027

0.001

5ST2 157

027

0.028

For RCCB 4P, N right and 6 MCB 1P+N


4-phase 10 mm2
4-phase 16 mm2

1
1

End caps for 5ST3 7, can be cut


For two-phase and three-phase busbars
For 4-phase busbars
Touch protection
For free connections, yellow (RAL 1004)
5 x 1 pin
Busbars, 12 MW, with fork-type connections,
can be cut to length, with end caps
For bus mounting RCCBs together
Three-phase + N, 16 mm2
1

216

End caps for 5ST2 145 busbars, can be cut to length


For three-phase busbars

Terminals up to 35 mm2 (stranded),


for direct infeed of 5ST2 145 busbar
Side-by-side mounting possible

5 units

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/25

Siemens AG 2011

Residual Current Protective Devices


5SM1 and 5SZ9 RCCB socket outlets

Overview
Number of
poles

Rated
current In

Rated residual
current In

mA

(Type A)

RCCB protective socket outlets


For mounting onto device box, equipped with RCCB and
2 SCHUKO socket outlets

16

10, 30

Molded-plastic enclosures, equipped with RCCB and


SCHUKO socket outlet

16

10

= Type A for AC and pulsating DC residual currents

Application
RCCB protective socket outlets
Molded-plastic enclosure equipped with RCCB and flush-type
SCHUKO socket outlet or flush-type SCHUKO double
socket outlet
For electric devices where there is a risk of accidental contact
with live parts in the event of damage

Rated voltage: 230 V AC, 50 Hz to 60 Hz


For outdoor connection of gardening equipment and socket
outlets in workshops or for agricultural purposes
Degree of protection IP21 (5SM1 920-.),
degree of protection IP54 (5SZ9 2.6).

Selection and ordering data


Rated
residual
current
In

Rated current DT

mA

Order No.

In

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

RCCB protective socket outlets


RCCB protective socket outlets according to VDE 0664,
for mounting on device boxes, equipped with residual
current operated circuit breaker and 2 childproof
SCHUKO socket outlets, degree of protection IP21
10

16

30

5SM1 920-5

1 unit

008

0.513

5SM1 920-8

1 unit

008

0.533

5SZ9 206

1 unit

008

0.761

5SZ9 216

1 unit

008

0.763

RCCB protective socket outlet according to VDE 0664 in


molded-plastic enclosure, equipped with residual current
operated circuit breaker and flush-mounted SCHUKO
socket outlet, degree of protection IP54
10
30

16

* You can order this quantity or a multiple thereof.

4/26

Siemens LV 10.1 2011

Siemens AG 2011

Residual Current Protective Devices


Accessories

Accessories
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Terminal covers, gray


For surface mounting, degree of protection IP40,
sealable, with 35 mm standard mounting rail
Up to 2.5 MW

5SW3 004

1 unit

008

0.091

Up to 4.5 MW

5SW3 005

1 unit

008

0.171

Up to 2.5 MW

5SW3 006

1/4 units

008

0.133

Up to 4.5 MW

5SW3 007

1 unit

008

0.162

5SW1 200

1 unit

008

0.447

Wall enclosures, gray


For flush mounting, degree of protection IP40,
with 35 mm standard mounting rail

Molded-plastic enclosures, gray


for surface mounting, degree of protection IP54,
sealable, with 35 mm standard mounting rail,
with transparent hinged lid
For 4.5 MW

Covers
Can be assembled as mini distribution board, suitable
for all devices, cover parts prepared for rail mounting of
conventional label caps,
comprising:
End plates (for snapping onto standard mounting rail) }

5ST2 134

10 units

027

0.021

Angled profile (approx. 1 m long)

5ST2 135

5 units

027

0.288

Alternative flat profiles


(as a cover between the rows of devices length
approx. 1 m)

5ST2 136

5 units

027

0.239

5SW3 313

1 set

008

0.012

5ST2 201

1 unit

027

0.013

5ST2 173

1 set

027

0.049

Touch protection
For RCCBs up to 80 A
1 set contains 12 units
Fixing parts
Plastic
4 MW
Inscription labels (white)
15 mm 9 mm, 3 frames with 44 labels each
Any attachment and inscription,
self-adhesive

Labeling systems
Inscription on self-adhesive labels for a uniform and tidy appearance in electrical power distribution.
The labeling program can be downloaded to your PC free of charge at:
www.siemens.com/beta
Recommended ELAT-3-747 labels for printing
out on normal printers can be ordered at:

Brady GmbH
Otto-Hahn-Str. 5-7
D-63222 Langen
Tel.: +49 (0) 61 03/75 98-660

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

4/27

Siemens AG 2011

Residual Current Protective Devices


Residual-current operated circuit breakers

Application
Standards1)

Field of application

Required In

Recommended Siemens residual current


protective devices

[mA]

5SM.
(Type A)

5SM3
5SM3 . . .-6KK12
SIQUENCE
SIGRES
(Type B/type B+)

DIN VDE 0100-410 Sockets  20 A and end current circuits in the outdoor area
 32 A

 30

--

--

DIN VDE 0100-482 Fire protection for particular risks or safety hazard

30, 300

--

DIN VDE 0100-551 Low-voltage generating sets

 30

--

--

DIN VDE 0100-559 Luminaires and lighting installations, display stands for lights

 30

--

--

DIN VDE 0100-701 Rooms with baths or showers, socket outlets in zone 3

 30

--

--

DIN VDE 0100-702 Swimming pools, zone 1 and 2

 30

--

DIN VDE 0100-704 Construction and demolition site installations, socket outlet
current circuits (single-phase operation) up to 32 A

 30

--

 500

--

 30

--

DIN VDE 0100-706 Conductive areas with limited freedom of movement

 30

--

--

DIN VDE 0100-708 Feeding points for caravan parking spaces, camping sites

 30

--

--

--

--

and for hand-held equipment


DIN VDE 0100-705 Agricultural and general horticultural premises
Socket outlet current circuits

DIN VDE 0100-710 Medical premises, depending on application group 1 or 2 and  30 or


equipment
 300
DIN VDE 0100-722 Portable buildings, vehicles, mobile homes for fairgrounds

 500

--

--

DIN VDE 0100-723 Classrooms with experiment equipment

 30

--

--

DIN VDE 0100-738 Fountains zone 2, general

 500

--

Socket outlets in zone 2

 30

--

Zones 0 and 1

 30

--

DIN VDE 0100-739 Additional protection against direct contact in homes

 30

--

--

DIN VDE 0118-100 Mining plants

 500

--

General requirements
for correct selection
when using res. current
protection

--

 300
 30

---

 30
 500

 30
 500

---

---

30 (recommended)

DIN EN 50178
(VDE 0160)

Fitting of power installations with electronic equipment

DIN VDE 0832-100 Traffic signals


Class T1
Class U1
BG FE
BGI 608

Selection and operation of electrical equipment on worksites


General:
Socket circuits  32 A
Socket circuits > 32 A
Frequency-controlled equipment:
With plug-and-socket device  32 A
With plug-and-socket device > 32 A
Chemical industry and food processing industries

1)

The standards of the range DIN VDE 0100-4.., -5.., -7.. essentially
correspond to the IEC standards of the range IEC 60364-4, -5, -7;
they have, however, been modified.

Note:
For reasons of basic fire protection, we recommend a maximum
rated residual current of 300 mA for residual current protective
devices.

4/28

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
5/2

Introduction

5/9

NEOZED Fuse Systems


Introduction
NEOZED fuse links
MINIZED switch disconnectors and
MINIZED fuse switch disconnectors
NEOZED fuse bases and accessories

5/12

DIAZED Fuse Systems

5/4
5/7
5/8

5/18
5/22

Cylindrical Fuse Systems


Cylindrical fuse sets and cylindrical
fuse holders
Compact fuse holders for motor
starter combinations N

5/25

Class CC Fuse Systems

5/27

Busbar Systems

5/33
5/42
5/44

LV HRC Fuse Systems


LV HRC fuse links
LV HRC signal detectors
LV HRC sockets and accessories

5/50
5/58
5/61

5/63

SITOR Semiconductor Fuses


SITOR LV HRC design
SITOR, cylindrical fuse design
NEOZED and DIAZED design,
SILIZED
Photovoltaic Fuses
Cylindrical fuse design

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Introduction

Overview
Standards

5/4

MINIZED switch disconnectors, bases, Fuse system:


fuse links from 2 A to 63 A of operaIEC 60269-3;
tional class gG and accessories. Every- DIN VDE 0636-3;
thing you need for a complete system.

Used in

Industry

NEOZED fuse systems

Field of application

Residential
buildings

Page

Non-residential
buildings

Devices

Safety switching
devices
IEC/EN 60947-3
DIN VDE 0638

DIAZED fuse systems

5/12

Fuse links from 2 A to 100 A in various


operational classes, base versions with
classic screw base connections.
A widely used fuse system.

IEC 60269-3;
DIN VDE 0635;
DIN VDE 0636-3;
CEE 16

5/18

Line protection or protection of switching devices.

IEC 60269-1, -2, -3;


NF C 60-200;
NF C 63-210, -211;
NBN C 63269-2,
CEI 32-4, -12

Cylindrical fuse systems


Cylindrical fuse sets and
cylindrical fuse holders

The fuse holders with touch protection


ensure the safe "no-voltage" replacement of fuse links.
Auxiliary switches can be retrofitted.

Compact fuse holders for motor


starter combinations

5/22

For installing fused loaded motor starter IEC 60947-4


combinations.

--

Class CC fuse systems

5/25

These comply with American standard


and have UL and SCA approval, for
customers exporting OEM products
and mechanical engineers.

Modern design with touch protection


acc. to BGV A3 for use in "branch circuit protection".

Busbar systems

5/2

Siemens LV 10.1 2011

5/27

Fuse holders:
UL 512; CSA 22.2
Fuse links:
UL 248-4; CSA 22.2

Busbars for NEOZED fuse bases,


EN 60439-1
NEOZED fuse disconnectors, MINIZED
switch disconnectors, DIAZED fuse
systems and cylindrical fuse systems.

Siemens AG 2011

Fuse Systems

Page

Field of application

Non-residential
buildings

Residential
buildings

Industry

Introduction
Devices

Standards

Used in

LV HRC fuse links

5/33

Fuse links from 2 A to 1250 A for selec- IEC 60269-1, -2;


tive line protection and plant protection EN 60269-1;
in non-residential buildings, industry
DIN VDE 0636-2
and power supply companies.

LV HRC signal detectors

5/42

Signal detectors for when a fuse is


tripped on all LV HRC fuse links with
combination or front indicators with
non-insulated grip lugs.

LV HRC fuse systems

Plus the comprehensive accessory


range required for NH fuse systems.

5/44

Fuse bases for screw or snap-on


IEC 60269-1, -2;
mounting onto standard mounting rails, EN 60269-1;
available as 1-pole or 3-pole version
DIN VDE 0636-2

SITOR LV HRC design

5/50

Fuse links in LV HRC design and a


huge variety of models support a wide
range of applications from 500 V to
1500 V and 150 A to 1250 A.
Fuses with slotted blade contacts, bolton links or female thread and special
designs.

--

--

SITOR, cylindrical fuse design

5/58

Fuse sets, fuse holders usable as fuse


switch disconnectors and fuse bases
up to 600/690 V AC and 400/700 V DC
from 1 A to 100 A in the sizes
10 mm 38 mm, 14 mm 51 mm and
22 mm 58 mm.

--

--

NEOZED and DIAZED design,


SILIZED

5/61

NEOZED fuse links for 400 V AC and


250 V DC and DIAZED for 500 V AC
and 500 V DC.

--

--

Cylindrical fuse design

5/63

Fuses with a rated voltage of


1000 V DC and operational class gPV
for the protection of photovoltaic modules and their connecting cables.

LV HRC sockets and accessories

SITOR semiconductor fuses

Photovoltaic fuses
IEC 60269-6 (draft)

Siemens LV 10.1 2011

5/3

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
Introduction

Overview
The NEOZED fuse system is primarily used in distribution technology and industrial switchgear assemblies. The system is easy
to use and is also approved for domestic installation.

The MINIZED switch disconnectors are primarily used in switchgear assemblies and control engineering. They are approved for
switching loads as well as for safe switching in the event of short
circuits. The MINIZED D02 is also suitable for use in the precounter sector in household applications in compliance with the
recommendations of the VDEW according to TAB 2007.

Due to its small footprint, the MINIZED D01 fuse switch disconnector is primarily used in control engineering.
The NEOZED fuse bases are the most cost-effective solution for
the application of NEOZED fuses. All NEOZED bases must be
fed from the bottom to ensure that the threaded ring is insulated
during removal of the fuse link. The terminals of the NEOZED
bases are available in different versions and designs to support
the various installation methods.

Benefits

MINIZED switch disconnectors


Clear and visible conductor connection that can be easily
checked. This facilitates cable entry and saves time
With draw-out technology for no-voltage replacement of fuses.
This provides enhanced safety.
The infeed of the devices can be from the top or the bottom.
This enables flexible application.

NEOZED fuse bases made of molded plastic


Clear and visible conductor connection that can be easily
checked. This facilitates cable entry and saves time
Greater safety for personnel thanks to terminals with touch
protection acc. to BGV A3 at incoming and outgoing feeders.
This ensures enhanced safety
Two type ranges with different terminals offer expanded application options.

NEOZED fuse switch disconnectors


With draw-out technology for no-voltage replacement of fuses.
This provides enhanced safety.
Extremely slim design with a single MW per pole. This saves
space and costs.

NEOZED fuse bases made of ceramic


Different terminal versions support a huge range of different
installation methods. This increases flexibility
These bases are the most widely used devices for applications with NEOZED fuses. An unrivaled cost-effective solution.

5/4

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
Introduction

Technical specifications
NEOZED fuse links
5SE2
IEC 60269-3; DIN VDE 0636-3

Standards

gG

Operational class
V AC

400

V DC

250

Rated current In

2 ... 100

Rated breaking capacity

kA AC

50

kA DC

Rated voltage Un

Using adapter sleeves

Non-interchangeability
Resistance to climate

Up to 45 at 95 % rel. humidity

Ambient temperature

-5 ... +40, humidity 90 % at 20


MINIZED
switch disconnectors

MINIZED
Fuse bases,
fuse switch
made of ceramic
disconnectors

D02

D01

D01

D02

D03

D01/02

5SG7 1

5SG7 6

5SG1 5
5SG5 5

5SG1 6
5SG5 6

5SG1 8

5SG1 .01
5SG5 .01

5SG1 .30
5SG1 .31
5SG5 .30

16/63

16/63

DIN VDE 0638

Standards

Comfort
bases

Fuse bases

IEC 60269-3; DIN VDE 0636-3

IEC/EN 60947-3
Main switch characteristic
EN 60204-1

Yes

--

--

Insulation characteristic
EN 60664-1

Yes

--

--

Rated voltage Un

V AC

230/400, 240/415

400

1P

V DC

65

48

250

2P in series

V DC

130

110

250

Rated current In

63

16

16

Rated insulation voltage

V AC

500

400

--

Rated impulse withstand voltage

kV AC

2.5

--

--

--

63

16

--

AC-22 B

63

16

--

AC-23 B

35

--

--

DC-22 B

63

--

--

Overvoltage category

63

100

Utilization category acc. to VDE 0638


AC-22
Utilization category acc. to EN 60947-3

Sealable
When switched on

Yes

Yes, with sealable screw caps

Mounting position

Any, but preferably vertical

Reduction factor of In with 18 pole


Side-by-side mounting

0.9

--

On top of one another, with vertical standard


mounting rail

0.87

--

Degree of protection acc. to IEC 60529

IP20, with connected conductors

Terminals
With touch protection acc. to BGV A3

Yes

Ambient temperature

Terminal versions

No

Yes

-5 ... +40, humidity 90 % at 20


--

--

K, S

K/S

--

--

Conductor cross-sections
Solid and stranded

mm2

1.5 ... 35

1.5 ... 16

1.5 ... 4

1.5 ... 25

10 ... 50

0.75 ... 35

1.5 ... 35

Flexible, with end sleeve

mm2

1.5 ... 35

1.5

1.5

1.5

10

--

--

Finely stranded, with end sleeve

mm2

--

--

0.75 ... 25 --

--

--

--

Tightening torques

Nm

1.2

1.2

3.5/2.5

2.5 ... 3

Siemens LV 10.1 2011

5/5

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
Introduction

More information

Fuse bases D01 with terminal version BB


Incoming feeders, clamp-type terminal B
Outgoing feeders, clamp-type terminal B

Fuse bases D02, with terminal version SS


Incoming feeders, saddle terminal S
Outgoing feeders, saddle terminal S

5/6

Siemens LV 10.1 2011

Fuse bases D02, with terminal version KS


Incoming feeders, screw head contact K
Outgoing feeders, saddle terminal S

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
NEOZED fuse links

Selection and ordering data


Sizes

Identification
color

In

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

A
NEOZED fuse sets
Rated voltage 400 V AC/250 V DC,
operational class gG
D01

D02

2
4
6

Pink
Brown
Green

}
}
}

5SE2 302
5SE2 304
5SE2 306

1
10 units
1
10 units
1 10/500 units

016
016
016

0.005
0.013
0.009

10
13
16

Red
Black
Gray

}
A
}

5SE2 310
5SE2 013-2A
5SE2 316

1 10/500 units
1
10 units
1 10/500 units

016
016
016

0.007
0.006
0.005

20
25
32

Blue
Yellow
Black

}
}
B

5SE2 320
5SE2 325
5SE2 332

1
1
1

10 units
10 units
10 units

016
016
016

0.011
0.010
0.013

35
40
50

Black
Black
White

}
B
}

5SE2 335
5SE2 340
5SE2 350

1
1
1

10 units
10 units
10 units

016
016
016

0.011
0.015
0.013

Copper

5SE2 363

10 units

016

0.015

Blue
Red

}
}

5SE2 280
5SE2 300

1
1

10 units
10 units

016
016

0.035
0.042

63
D03

80
100

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/7

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
MINIZED switch disconnectors and
MINIZED fuse switch disconnectors

Selection and ordering data


Sizes

Number of In
poles

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW

MINIZED switch disconnectors with fuses


Using draw-out technology with touch protection to
BGV A3 (adapter sleeves not included in delivery)

D02

1P

63

1.5

5SG7 113

1 unit

016

0.141

1P+N

63

5SG7 153

1 unit

016

0.259

2P

63

5SG7 123

1 unit

016

0.276

3P

63

4.5

5SG7 133

1 unit

016

0.411

3P+N

63

5SG7 163

1 unit

016

0.524

4.5

B
B
B

5SG7 133-8BA25
5SG7 133-8BA35
5SG7 133-8BA50

1
1
1

1 unit
1 unit
1 unit

016
016
016

0.450
0.448
0.455

5SH5 532

1 unit

016

0.012

5SH5 527

1 10/100 units

016

0.001

Versions for Austria only,


with permanently fitted adapter sleeves,
incl. fuse set
D02

3P

25
35
50

Locking caps
In D02 MINIZED switch disconnectors
for applications in the precounter sector

Reducers
For fuse links D01
in MINIZED switch disconnectors D02
Auxiliary switches (AS)
For MINIZED switch disconnectors D02
}

5ST3 010

1 unit

027

0.066

2 NO

5ST3 011

1 unit

027

0.055

2 NC

5ST3 012

1 unit

027

0.055

1 NO + 1 NC

0.5

For technical specifications, see chapter 3


"Miniature Circuit Breakers" > "Additional
components"
Auxiliary switches (AS) with TEST button
For MINIZED switch disconnectors D02
A

5ST3 010-2

1 unit

027

0.045

2 NO

1 NO + 1 NC

0.5

5ST3 011-2

1 unit

027

0.045

2 NC

5ST3 012-2

1 unit

027

0.045

For technical specifications, see chapter 3


"Miniature Circuit Breakers" > "Additional
components"
MINIZED fuse switch disconnectors
For industrial applications
With draw-out technology and touch protection to
BGV A3 (not compatible with NEOZED adapter
sleeves)
D01

1P
1P+N
2P

16
16
16

1
2
2

A
B
B

5SG7 610
5SG7 650
5SG7 620

1
1
1

1 unit
1 unit
1 unit

016
016
016

0.082
0.169
0.165

3P
3P+N

16
16

3
4

A
B

5SG7 630
5SG7 660

1
1

1 unit
1 unit

016
016

0.241
0.323

For busbars, see page 5/29.

* You can order this quantity or a multiple thereof.

5/8

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
NEOZED fuse bases and accessories

Selection and ordering data


Sizes

Number of
poles

In

Matching
cover1)

Terminals2) Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW

NEOZED comfort bases made of molded plastic


With touch protection according to BGV A3
D01
D02

1P

16
63

---

1.5

}
}

5SG1 301
5SG1 701

1
1

3 units
3 units

016
016

0.114
0.116

D01
D02

3P

16
63

---

4.5

}
}

5SG5 301
5SG5 701

1
1

1 unit
1 unit

016
016

0.382
0.380

A
A

5SG1 330
5SG1 730

1
1

6 units
6 units

016
016

0.077
0.085

B
A

5SG1 331
5SG1 731

1
1

6 units
6 units

016
016

0.069
0.081

5SG5 330
5SG5 730

1
1

2 units
2 units

016
016

0.227
0.270

}
}
}

5SG1 553
5SG1 653
5SG1 693

1
1
1

6 units
6 units
6 units

016
016
016

0.065
0.091
0.080

NEOZED fuse bases made of molded plastic


For snap-on mounting on standard mounting rails, with cover
D01
D02

1P

16
63

(A1)
(A1)

1.5
1.5

For snap-on mounting on standard mounting rails,


without cover
D01
D02

1P

16
63

A1
A1

1.5
1.5

For snap-on mounting on standard mounting rails, with cover


D01
D02

3P

16
63

(A2)
(A2)

4.5
4.5

A
A

NEOZED fuse bases made of ceramic


For snap-on mounting on standard mounting rails, with cover
D01
D02
D02

1P

16 (A4)
63 (A10)
63 (A10)

BB
SS
KS

1.5
1.5
1.5

For snap-on mounting on standard mounting rails,


without cover
D01
D02
D02
D03

1P

16
63
63
100

A4
A10
A10
A6, A9

BB
SS
KS
KS

1.5
1.5
1.5
2.5

B
}
B
A

5SG1 595
5SG1 655
5SG1 695
5SG1 812

1
6 units
1
6 units
1
6 units
1 10 units

016
016
016
016

0.059
0.082
0.078
0.190

BB
SS
KS

1.5
1.5
2.5

B
B
B

5SG1 590
5SG1 650
5SG1 810

1
6 units
1
6 units
1 10 units

016
016
016

0.056
0.081
0.184

}
B
B

5SG1 594
5SG1 694
5SG1 813

1
6 units
1
6 units
1 10 units

016
016
016

0.085
0.107
0.249

5SG5 553
5SG5 653
5SG5 693

1
1
1

016
016
016

0.203
0.272
0.256

For screw fixing only, without cover


D01
D02
D03

1P

16 A4
63 A10
100 A6, A9

For snap-on mounting on standard mounting rails,


with cap
D01
D02
D03

1P

16 (A8)
63 (A8)
100 (A9)

BB
SS
KS

1.5
1.5
2.5

For snap-on mounting on standard mounting rails, with cover


D01
D02
D02

1)

3P

16 (A5)
63 (A11)
63 (A11)

Covers in parentheses are included in delivery.


Covers without parentheses are not included in delivery.

BB
SS
KS

}
}
}

4.5
4.5
4.5

2)

2 units
2 units
2 units

For terminal versions, see page 5/6.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/9

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
NEOZED fuse bases and accessories
Sizes

Number of
poles

In

Matching
cover

Terminals1) Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW

NEOZED fuse bases made of ceramic


For snap-on mounting on standard mounting rails,
without cover
D01
D02
D02

3P

16 A5
63 A11
63 A11

BB
SS
KS

4.5
4.5
4.5

B
B
B

5SG5 555
5SG5 655
5SG5 695

1
1
1

2 units
2 units
2 units

016
016
016

0.188
0.260
0.240

BB
SS
KS

4.5
4.5
4.5

B
B
B

5SG5 550
5SG5 650
5SG5 690

1
1
1

2 units
2 units
2 units

016
016
016

0.189
0.260
0.235

For screw fixing only, without cover


D01
D02
D02

3P

16 A5
63 A11
63 A11

NEOZED covers1)
Made of molded plastic, plug-in,
for fuse base made of molded plastic
D01,
D02

A1

1.5

5SH5 244

1 15 units

016

0.002

D01,
D02

A2

4.5

5SH5 245

5 units

016

0.005

For fuse bases made of ceramic


D01
D02

A4
A10

1.5
1.5

B
B

5SH5 251
5SH5 253

1 15 units
1 15 units

016
016

0.008
0.006

D01
D02

A5
A11

4.5
4.5

C
C

5SH5 252
5SH5 254

1
1

5 units
5 units

016
016

0.022
0.023

A6

2.5

5SH5 233

1 20 units

016

0.019

A8

5SH5 235

5 units

016

0.021

A9

5SH5 234

1 10 units

016

0.065

Screw-on
D03

NEOZED caps
Made of molded plastic, plug-in
D01, D02
Screw-on
D03

1)

For terminal versions, see page 5/6.

* You can order this quantity or a multiple thereof.

5/10

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
NEOZED Fuse Systems
NEOZED fuse bases and accessories
Sizes

For fuse links

Identification Mount- DT
color
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW

NEOZED screw caps


Molded plastic, with inspection hole
}
}

5SH4 116
5SH4 163

1 10/1000 units
1 10/200 units

016
016

0.007
0.009

A
A
A

5SH4 316
5SH4 363
5SH4 100

1
1
1

10 units
10 units
3 units

016
016
016

0.017
0.022
0.074

}
}

5SH4 317
5SH4 362

1
1

20 units
20 units

016
016

0.017
0.019

Pink
Brown
Green

}
A
}

5SH5 002
5SH5 004
5SH5 006

1
1
1

10 units
10 units
10 units

016
016
016

0.001
0.001
0.001

10/13

Red

5SH5 010

10 units

016

0.001

20
25
32/35/40

Blue
Yellow
Black

}
}
}

5SH5 020
5SH5 025
5SH5 035

1
1
1

10 units
10 units
10 units

016
016
016

0.002
0.001
0.003

50

White

5SH5 050

10 units

016

0.001

80

Silver

5SH5 080

25 units

016

0.001

Pink
Brown
Green

A
A
A

5SH5 402
5SH5 404
5SH5 406

1
1
1

10 units
10 units
10 units

016
016
016

0.001
0.005
0.002

Red
Gray

A
A

5SH5 410
5SH5 416

1
1

10 units
10 units

016
016

0.014
0.002

5SH5 100

1/10 units

016

0.023

5SH5 400

25 units

016

0.002

5SH5 417

25 units

016

0.001

5SH5 503

1 unit

016

0.299

D01
D02
Ceramic
D01, sealable
D02, sealable
D03
Ceramic, with inspection hole
D01
D02

NEOZED adapter sleeves


D01

D02

D03

2
4
6

For fuse links D01 in base D02 and


MINIZED switch disconnectors D02
D02

2
4
6
10/13
16

NEOZED adapter sleeve fitters

NEOZED retaining springs


For fuse links D01 in screw caps
D02

2 ... 16

For fuse links D01 in screw caps DL1)


DL1)

2 ... 16

Busbar adapters
for mounting D02 MINIZED switch discon4.5
nectors on busbars 12 5 mm at a distance
of 40 mm
Rated current 63 A, 16 mm

1)

This spring enables the use of NEOZED fuses in DL fuse bases, e.g. in unrenovated prefabricated buildings.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/11

Siemens AG 2011

Fuse Systems
DIAZED fuse systems

Overview
The DIAZED fuse system is one of the oldest fuse systems in the
world. It was developed by Siemens as far back as 1906. It is still
the standard fuse system in many countries to this day. It is particularly widely used in the harsh environments of industrial applications.
The series is available with rated voltages from 500 A to 750 V.

All DIAZED bases must be fed from the bottom to ensure an insulated threaded ring when the fuse link is being removed. Reliable contact of the fuse links is only ensured when used together
with DIAZED screw adapters.

The terminals of the DIAZED bases are available in different versions and designs to support the various installation methods.
The high-performing EZR bus-mounting system for screw connection is an outstanding feature. The busbars, which are particularly suited for bus-mounting bases, have a load capacity of up
to 150 A with lateral infeed.
DIAZED stands for Diametral gestuftes zweiteiliges Sicherungssystem mit Edisongewinde (diametral two-step fuse system with
Edison screw).

Benefits
DIAZED fuse systems are a result of a well-designed modular
system which enables the components to be combined in any
way to meet the various requirements and to facilitate different
installation methods.

$
%
&
(
)
*
+
,
.
/

1
10

7
5
2
9
6

11

DIAZED base
DIAZED cover
DIAZED cover ring
DIAZED cap
DIAZED fuse link, DII
DIAZED fuse link, NDz
DIAZED screw adapter
DIAZED adapter sleeve
DIAZED screw cap
Busbar, oblong hole, single-phase
Terminal, fork-type terminal, non-insulated

I201_16013a

Technical specifications
5SA, 5SB, 5SC, 5SD
IEC 60269-3; DIN VDE 0635; DIN VDE 0636-3; CEE 16

Standards
Operational class

Acc. to IEC 60269; DIN VDE 0636

Characteristic

Acc. to DIN VDE 0635

gG
Slow and quick

Rated voltage Un

V AC
V DC

500, 690, 750


500, 600, 750

Rated current In

2 ... 100

Rated breaking capacity

kA AC
kA DC

50, 40 at E16
8, 1.6 at E16
Any, but preferably vertical

Mounting position

Using screw adapter or adapter sleeves

Non-interchangeability
Degree of protection

Acc. to IEC 60529

IP20, with connected conductors

Resistance to climate

Up to 45, at 95 % rel. humidity

Ambient temperature

-5 ... +40, humidity 90 % at 20


Terminal version
B

DII

DIII

NDz

DII

DIII

DIII

DIV

DII

DIII

mm2
mm2
mm2

1.5
10
10

2.5
25
25

1.0
6
6

1.5
10
10

2.5
25
25

2.5
25
25

10
50
50

1.5
35
35

1.5
35
35

Nm
Nm
Nm
Nm

1.2
2.0
2.5
3.5

Size
Conductor cross-sections
Rigid, min.
Rigid, max.
Flexible, with end sleeve
Tightening torques

Screw M4
Screw M5
Screw M6
Screw M8

5/12

Siemens LV 10.1 2011

--4
--

Siemens AG 2011

Fuse Systems
DIAZED fuse systems

Selection and ordering data


Sizes Un

Identifica- Thread
tion color

In

V AC/V DC A

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW

DIAZED fuse links


Operational class gG
DII

500/500

DIII

500/500

DIV

500/400

2
4
6

Pink
Brown
Green

10
16
20
25

Red
Gray
Blue
Yellow

32
35
50
63

Black
Black
White
Copper

80 Silver
100 Red

}
}
}

5SB2 11
5SB2 21
5SB2 31

1
1
1

5 units
5 units
5 units

016
016
016

0.019
0.024
0.023

}
}
}
}

5SB2 51
5SB2 61
5SB2 71
5SB2 81

1
1
1
1

5 units
5 units
5 units
5 units

016
016
016
016

0.022
0.028
0.035
0.030

E33

B
A
A
A

5SB4 010
5SB4 11
5SB4 21
5SB4 31

1
1
1
1

5 units
5 units
5 units
5 units

016
016
016
016

0.046
0.051
0.048
0.054

R1"

B
B

5SC2 11
5SC2 21

1
1

3 units
3 units

016
016

0.129
0.119

E16

B
B
B

5SA2 11
5SA2 21
5SA2 31

1 10 units
1 10 units
1 10 units

016
016
016

0.011
0.020
0.015

B
B
B
B

5SA2 51
5SA2 61
5SA2 71
5SA2 81

1
1
1
1

10 units
10 units
10 units
10 units

016
016
016
016

0.012
0.013
0.014
0.030

B
B
B

5SA1 11
5SA1 21
5SA1 31

1 10 units
1 10 units
1 10 units

016
016
016

0.011
0.011
0.015

B
B
B
B

5SA1 51
5SA1 61
5SA1 71
5SA1 81

1
1
1
1

10 units
10 units
10 units
10 units

016
016
016
016

0.012
0.014
0.014
0.016

B
B
B
B

5SB1 11
5SB1 21
5SB1 31
5SB1 41

1
1
1
1

5 units
5 units
5 units
5 units

016
016
016
016

0.026
0.025
0.026
0.653

A
A
A

5SB1 51
5SB1 61
5SB1 71

1
1
1

5 units
5 units
5 units

016
016
016

0.025
0.028
0.032

E27

Characteristic: slow
TNDz 500/500

2
4
6

Pink
Brown
Green

10
16
20
25

Red
Gray
Blue
Yellow

Characteristic: quick
NDz

DII

500/500

500/500

2 Pink
4 Brown
6 Green
10
16
20
25

Red
Gray
Blue
Yellow

2
4
6
10

Pink
Brown
Green
Red1)

E16

E27

10 Red
16 Gray
20 Blue
25 Yellow
DIII

500/500

DIV

500/500

5SB1 81

5 units

016

0.031

E33

A
A
A

5SB3 11
5SB3 21
5SB3 31

1
1
1

5 units
5 units
5 units

016
016
016

0.050
0.049
0.054

R1"

B
B

5SC1 11
5SC1 21

1
1

3 units
3 units

016
016

0.123
0.124

B
B
B

5SD8 002
5SD8 004
5SD8 006

1
1
1

5 units
5 units
5 units

016
016
016

0.068
0.071
0.067

10 Red
16 Gray

B
B

5SD8 010
5SD8 016

1
1

5 units
5 units

016
016

0.067
0.072

20 Blue
25 Yellow

B
B

5SD8 020
5SD8 025

1
1

5 units
5 units

016
016

0.069
0.072

35 Black
50 White
63 Copper

B
B
B

5SD8 035
5SD8 050
5SD8 063

1
1
1

5 units
5 units
5 units

016
016
016

0.072
0.075
0.078

35 Black
50 White
63 Copper
80 Silver
100 Red

Operational class gG, use 5SF1 and 5SF5 fuse base


made of ceramic
For 2 A ... 25 A, use adaptor screw DII
DIII

1)

690/600

2 Pink
4 Brown
6 Green

E33

Use adaptor screw 6 A.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/13

Siemens AG 2011

Fuse Systems
DIAZED fuse systems
Sizes

Un

Identifi- Thread
cation
color

In

Terminals

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

V AC/V DC A
DIAZED fuse links
Characteristic: quick,
also for direct current railway facilities
For 2 A ... 25 A, use adaptor screw DII

DIII

750/750

2 Pink
4 Brown
6 Green

E33

A
B
B

5SD6 01
5SD6 02
5SD6 03

1
1
1

5 units
5 units
5 units

016
016
016

0.066
0.072
0.068

10 Red
16 Gray

B
B

5SD6 04
5SD6 05

1
1

5 units
5 units

016
016

0.072
0.042

20
25
35
50
63

B
A
B
B
B

5SD6 06
5SD6 07
5SD6 08
5SD6 10
5SD6 11

1
1
1
1
1

5 units
5 units
5 units
5 units
5 units

016
016
016
016
016

0.074
0.072
0.072
0.077
0.078

Blue
Yellow
Black
White
Copper

DIAZED fuse bases made of ceramic


1P, for standard mounting rail
25

E16

KK

5SF1 012

5 units

016

0.062

DII

NDz

500/500

25

E27

BB

5SF1 005

5 units

016

0.093

DIII1)

63

E33

BS

5SF1 205

5 units

016

0.142

DIII1)

63

E33

SS

5SF1 215

5 units

016

0.141

1P, for screw fixing


25

E16

KK

5SF1 01

5 units

016

0.057

DII

NDz

500/500

25

E27

BB

5SF1 024

5 units

016

0.100

DIII1)

63

E33

BS

5SF1 224

5 units

016

0.143

DIII1)

63

E33

SS

5SF1 214

5 units

016

0.146

5SF1 401

1 unit

016

0.604

1P, with flat terminal


DIV

100

R1"

3P, for standard mounting rail,


with cap and N-type fixpoint terminal
DII

500/500

DIII1)

3 25

E27

BB

5SF5 067

1 unit

016

0.449

3 63

E33

BB

5SF5 237

1 unit

016

0.635

3P, for screw fixing,


with cap and N-type fixpoint terminal
DII

500/500

DIII1)

3 25

E27

KB

5SF5 066

1 unit

016

0.441

3 63

E33

KB

5SF5 236

1 unit

016

0.624

DIAZED fuse bases made of molded plastic


With touch protection according to BGV A3
1P, for standard mounting rail or screw fixing
DII

500/500

DIII

25

E27

5SF1 060

1 3/108 units

016

0.146

63

E33

5SF1 260

1 3/132 units

016

0.200

3 25

E27

5SF5 068

1/36 units

016

0.475

3 63

E33

5SF5 268

1/44 units

016

0.595

3P
DII

500/500

DIII

1)

Also for 690 V AC/600 V DC.

* You can order this quantity or a multiple thereof.

5/14

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
DIAZED fuse systems
Sizes

Un

In

V AC/V DC

Thread

Terminals DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

DIAZED components 750 V


DIAZED fuse bases
1P, for screw fixing,
with fine thread and cap
DIII

750/750

63

E33S

KK

5SF4 230

1 unit

016

0.504

5SH1 161

5 units

016

0.134

DIAZED screw caps


Made of ceramic, with fine thread
DIII

750/750

63

E33S

DIAZED EZR bus-mounting bases


1P, to snap onto EZR busbars
For screw fixing
DII

500/500

25

E27

5SF6 005

5 units

016

0.080

DIII

500/500

63

E33

5SF6 205

5 units

016

0.114

0.013

DIAZED screw caps


Molded plastic, with inspection hole, black,
not for SILIZED fuse links
NDz

500/500

25

E16

5SH1 112

20 units

016

DII

500/500

25

E27

5SH1 221

5/200 units

016

0.024

63

E33

5SH1 231

5/5000 units

016

0.038

25

E27

5SH1 12

1 50/30000 units

016

0.037

63

E33

5SH1 13

30 units

016

0.063

DIII
Ceramic
DII

500/500

DIII

Ceramic, with inspection hole, sealable


DII

500/500

DIII

25

E27

5SH1 22

50/5000 units

016

0.046

63

E33

5SH1 23

30/5000 units

016

0.068

R1"

5SH1 141

1 unit

016

0.223

E33

5SH1 170

5 units

016

0.095

Ceramic
DIV

500/500

100

Ceramic, prolonged version


DIII

690/600

63

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/15

Siemens AG 2011

Fuse Systems
DIAZED fuse systems
Sizes

Thread

For
fuse links

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

A
DIAZED screw adapters
NDz

E16

2
4
6

C
C
C

5SH3 28
5SH3 31
5SH3 05

1
1
1

20 units
20 units
20 units

016
016
016

0.003
0.002
0.004

10
16

C
C

5SH3 06
5SH3 07

1
1

20 units
20 units

016
016

0.003
0.002

2
4
6

}
}
}

5SH3 10
5SH3 11
5SH3 12

1 25/1500 units
1 25/1500 units
1 25/1500 units

016
016
016

0.014
0.009
0.015

10
16
20

}
}
}

5SH3 13
5SH3 14
5SH3 15

1 25/1500 units
1 25/1500 units
1 25/1500 units

016
016
016

0.021
0.008
0.013

25

5SH3 16

1 25/1500 units

016

0.012

35
50
63

}
}
}

5SH3 17
5SH3 18
5SH3 20

1
1
1

25/850 units
25/850 units
25/850 units

016
016
016

0.025
0.018
0.019

80
100

C
C

5SH3 21
5SH3 22

1 10/1000 units
1 10/1000 units

016
016

0.006
0.004

For NDz/TNDz fuse links in base DII

5SH3 01

10 units

016

0.011

For DII fuse links in DIII base

5SH3 02

10 units

016

0.012

5SH3 703

1 unit

016

0.046

}
}

5SH2 032
5SH2 232

1
1

10/620 units
10/620 units

016
016

0.016
0.020

A
A
A

5SH2 01
5SH2 02
5SH2 22

1
1
1

5 units
5 units
5 units

016
016
016

0.044
0.249
0.049

Also for 5SF2 30 to 750 V


DII

E27

Also for 5SF2 30 to 750 V


DIII

E33

DIAZED adapter sleeves


DIV

R1"

DIAZED adapter sleeves for screw caps

DIAZED adapter sleeve fitters


DII/DIII

DIAZED covers
Made of molded plastic
Not for SILIZED fuse links
DII
DIII

5 bases = 12 MW E27
4 bases = 12 MW E33

DIAZED caps
Made of molded plastic
NDz
DII
DIII

E16
E27
E33

* You can order this quantity or a multiple thereof.

5/16

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
DIAZED fuse systems
Sizes

Thread

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

DIAZED cover rings


Ceramic DII and DIII, also for EZR bus-mounting base
DII
DIII

E27
E33

B
B

5SH3 32
5SH3 34

1
1

10 units
10 units

016
016

0.024
0.031

A
A

5SH3 401
5SH3 411

1
1

5/60 units
5/60 units

016
016

0.014
0.020

Made of molded plastic, also for EZR bus-mounting base


DII
DIII

E27
E33

More information

DIII fuse bases with terminal version BS


Outgoing feeders (top), saddle terminal S
Incoming feeders (bottom), clamp-type terminal B

NDz fuse bases with terminal version KK


Outgoing feeders (top), screw head contact K
Incoming feeders (bottom), screw head contact K

DIII fuse bases with terminal version BB


Outgoing feeders (top), clamp-type terminal B
Incoming feeders (bottom), clamp-type terminal B

DII fuse bases with terminal version SS


Outgoing feeders (top), saddle terminal S
Incoming feeders (bottom), saddle terminal S

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/17

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems
Cylindrical fuse sets and
cylindrical fuse holders

Overview

Benefits

Cylindrical fuses are standard in Europe. There are a range of


different cylindrical fuse links and holders that comply with the
standards IEC 60269-1, -2 and -3, and which are suitable for use
in industrial applications. In South West Europe they are also
approved for use in residential buildings.

The cylindrical fuse holders are also approved to UL 512.


The cylindrical fuse holders are tested and approved as fuse
disconnectors according to the switching device standard
IEC 60947-3. They are not suitable for switching loads.

Devices with pole number 1P+N are available in a single


modular width. This reduces the footprint by 50 %.
The sliding catch for type ranges 8 x 32 mm and 10 x 38 mm
enables the removal of individual devices from the assembly.
Space for a spare fuse in the plug-in module enables the fast
replacement of fuses. This saves time and money and
increases plant availability.
A flashing LED signals that a fuse link has been tripped. This
enables fast detection during runtime.

Cylindrical fuse holders can be supplied with or without signal


detectors. In the case of devices with signal detector, a small
electronic device with LED is located behind an inspection
window in the plug-in module. If the inserted fuse link is tripped,
this is indicated by the LED flashing.
The switching state of the fuse holder can be signaled over a
side-mounted auxiliary switch, which enables the integration of
the fuses in the automation process.

Technical specifications
Cylindrical fuse links
mm mm

Sizes

3NW6 3..

3NW6 0..

3NW6 1..

3NW6 2..

3NW8 0..

3NW8 1..

3NW8 2..

8 32

10 38

14 51

22 58

10 38

14 51

22 58

IEC 60269-1, -2, -3; NF C 60-200; NF C 63-210, -211; NBN C 63269-2, CEI 32-4, -12

Standards

gG

Operational class
Rated voltages Un

V AC

400 or 500

Rated current In

2 ... 20

kA AC
kA AC

100
20

aM
2 ... 32

4 ... 50

8 ... 100

0.5 ... 25

2 ... 50

10 ... 100

Rated breaking capacity


500 V version
400 V version

Any, but preferably vertical

Mounting position

Cylindrical fuse holders


mm mm

Sizes

3NW7 3..

3NW7 0..

3NW7 1..

3NW7 2..

8 32

10 38

14 51

22 58

IEC 60269-1, -2, -3; NF C 60-200; NF C 63-210, -211; NBN C 63269-2-1, CEI 32-4, -12

Standards

---

U
s

V AC
V AC

400
400

690
600

Rated current In

A AC

20

32

Rated breaking capacity

kA

20

100

Acc. to UL
Acc. to CSA

Approvals
Rated voltage Un

Acc. to UL/CSA

Switching capacity
Utilization category

---

50

100

2.5 ... 10
2.5 ... 25
2.5 ... 16

4 ... 10
4 ... 50
4 ... 35

6 ... 10

--

2.0

2.5

AC-20B (switching without load), DC-20B

No-voltage changing
Of fuse links

Yes

Sealable
When installed

Yes
Any, but preferably vertical

Mounting position
Degree of protection

U
s

Acc. to IEC 60529

IP20, with connected conductors

Terminals with touch protection


According to BGV A3 at incoming
and outgoing feeder
Ambient temperature

Yes

-5 ... +40, humidity 90 % at +20

mm2
mm2
mm2

0.5 ... 10
0.5 ... 10
0.5 ... 10

Conductor cross-sections
Rigid
Stranded
Finely stranded, with end sleeve

--

AWG (American Wire Gauge)


Tightening torques

5/18

Siemens LV 10.1 2011

Nm

1.2

10 ... 20

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems
Cylindrical fuse sets and
cylindrical fuse holders

Selection and ordering data


Sizes

In

Un

mm mm

V AC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Cylindrical fuse links,


operational class gG
8 32

2
4
6

400

B
B
B

3NW6 302-1
3NW6 304-1
3NW6 301-1

1
1
1

10 units
10 units
10 units

018
018
018

0.004
0.004
0.011

B
B
B

3NW6 303-1
3NW6 305-1
3NW6 307-1

1
1
1

10 units
10 units
10 units

018
018
018

0.001
0.001
0.004

}
}
}

3NW6 002-1
3NW6 004-1
3NW6 001-1

1
1
1

10 units
10 units
10 units

018
018
018

0.009
0.008
0.008

8
10
12

B
}
B

3NW6 008-1
3NW6 003-1
3NW6 006-1

1
1
1

10 units
10 units
10/100 units

018
018
018

0.008
0.008
0.008

16
20
25

}
B
B

3NW6 005-1
3NW6 007-1
3NW6 010-1

1
1
1

10 units
10 units
10 units

018
018
018

0.008
0.009
0.001

10
16
20
10 38

14 51

2
4
6

32

400

3NW6 012-1

10 units

018

0.008

4
6
8

500

B
B
B

3NW6 104-1
3NW6 101-1
3NW6 108-1

1
1
1

10 units
10 units
10/100 units

018
018
018

0.019
0.012
0.019

10
12
16

B
B
B

3NW6 103-1
3NW6 106-1
3NW6 105-1

1
1
1

10 units
10/100 units
10 units

018
018
018

0.022
0.017
0.023

20
25
32

B
B
B

3NW6 107-1
3NW6 110-1
3NW6 112-1

1
1
1

10 units
10 units
10 units

018
018
018

0.021
0.221
0.023

B
B

3NW6 117-1
3NW6 120-1

1
1

10 units
10 units

018
018

0.018
0.021

B
B
B

3NW6 208-1
3NW6 203-1
3NW6 206-1

1
1
1

10/100 units
10/100 units
10/100 units

018
018
018

0.051
0.052
0.056

16
20
25

B
B
B

3NW6 205-1
3NW6 207-1
3NW6 210-1

1
1
1

10 units
10 units
10 units

018
018
018

0.052
0.055
0.054

32
40
50

B
B
B

3NW6 212-1
3NW6 217-1
3NW6 220-1

1
1
1

10 units
10 units
10 units

018
018
018

0.052
0.048
0.054

63
80
100

B
B
B

3NW6 222-1
3NW6 224-1
3NW6 230-1

1
1
1

10 units
10 units
10 units

018
018
018

0.068
0.051
0.053

B
B

3NW8 000-1
3NW8 011-1

1
1

10 units
10 units

018
018

0.001
0.008

2
4
6

B
B
B

3NW8 002-1
3NW8 004-1
3NW8 001-1

1
1
1

10 units
10 units
10 units

018
018
018

0.007
0.007
0.006

8
10
12

B
A
B

3NW8 008-1
3NW8 003-1
3NW8 006-1

1
1
1

10 units
10 units
10/100 units

018
018
018

0.011
0.005
0.007

16
20
25

B
B
B

3NW8 005-1
3NW8 007-1
3NW8 010-1

1
1
1

10 units
10 units
10 units

018
018
018

0.008
0.006
0.008

B
B
B

3NW8 102-1
3NW8 104-1
3NW8 101-1

1
1
1

10/50 units
10 units
10/50 units

018
018
018

0.018
0.018
0.001

8
10
12

B
B
B

3NW8 108-1
3NW8 103-1
3NW8 106-1

1
1
1

10/50 units
10 units
10/50 units

018
018
018

0.018
0.016
0.018

16
20
25

B
B
B

3NW8 105-1
3NW8 107-1
3NW8 110-1

1
1
1

10 units
10 units
10 units

018
018
018

0.017
0.016
0.186

32
40
50

B
B
B

3NW8 112-1
3NW8 117-1
3NW8 120-1

1
1
1

10 units
10 units
10 units

018
018
018

0.019
0.018
0.019

40
50
22 58

500

8
10
12

400
500

400

Cylindrical fuse links,


operational class aM
10 38

14 51

0.5
1

2
4
6

500

400
500

400

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/19

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems
Cylindrical fuse sets and
cylindrical fuse holders
Sizes

In

mm mm

22 58

Number of
poles

DT

Order No.

PS*/
P. unit

PG

Weight
per PU
approx.

B
B

3NW8 203-1
3NW8 206-1

1 10/50 units
1 10/50 units

018
018

0.048
0.048

16
20
25

B
B
B

3NW8 205-1
3NW8 207-1
3NW8 210-1

1 10/50 units
1
10 units
1
10 units

018
018
018

0.048
0.046
0.040

32
40
50

B
B
B

3NW8 212-1
3NW8 217-1
3NW8 220-1

1
1
1

10 units
10 units
10 units

018
018
018

0.052
0.047
0.049

63
80
100

B
B
B

3NW8 222-1
3NW8 224-1
3NW8 230-1

1
1
1

10 units
10 units
10 units

018
018
018

0.046
0.054
0.050

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

10
12

Un

Price
PU
per PU (UNIT,
SET,
M)

kg

V AC
500

400

In

For fuse links


of size

Mount- DT
ing
width

mm mm

MW

Order No.

kg

Cylindrical fuse holders with signal detector


1P
20
32

8 32
10 38

1
1

C
A

3NW7 314
3NW7 014

1
1

1 unit
1 unit

018
018

0.067
0.066

50
100

14 51
22 58

1.5
2

B
B

3NW7 112
3NW7 212

1
1

1 unit
1 unit

018
018

0.100
0.150

20
32

8 32
10 38

1
1

C
A

3NW7 354
3NW7 054

1
1

1 unit
1 unit

018
018

0.082
0.080

50
100

14 51
22 58

3
4

B
B

3NW7 152
3NW7 252

1
1

1 unit
1 unit

018
018

0.224
0.359

20
32

8 32
10 38

2
2

C
A

3NW7 324
3NW7 024

1
1

1 unit
1 unit

018
018

0.135
0.134

50
100

14 51
22 58

3
4

B
B

3NW7 122
3NW7 222

1
1

1 unit
1 unit

018
018

0.217
0.328

20
32

8 32
10 38

3
3

C
A

3NW7 334
3NW7 034

1
1

1 unit
1 unit

018
018

0.198
0.199

50
100

14 51
22 58

4.5
6

B
B

3NW7 132
3NW7 232

1
1

1 unit
1 unit

018
018

0.327
0.495

20
32

8 32
10 38

3
3

C
A

3NW7 364
3NW7 064

1
1

1 unit
1 unit

018
018

0.216
0.215

50
100

14 51
22 58

6
8

B
B

3NW7 162
3NW7 262

1
1

1 unit
1 unit

018
018

0.444
0.681

1P+N

2P

3P

3P+N

Cylindrical fuse holders without signal detector


1P
20
32

8 32
10 38

1
1

A
}

3NW7 313
3NW7 013

1
1

1 unit
1/12 units

018
018

0.066
0.076

50
100

14 51
22 58

1.5
2

}
}

3NW7 111
3NW7 211

1
1

1 unit
1 unit

018
018

0.108
0.165

20
32

8 32
10 38

1
1

A
}

3NW7 353
3NW7 053

1
1

1 unit
1 unit

018
018

0.080
0.078

50
100

14 51
22 58

3
4

B
B

3NW7 151
3NW7 251

1
1

1 unit
1 unit

018
018

0.237
0.362

20
32

8 32
10 38

2
2

A
}

3NW7 323
3NW7 023

1
1

1 unit
1/6 units

018
018

0.133
0.132

50
100

14 51
22 58

3
4

}
}

3NW7 121
3NW7 221

1
1

1 unit
1 unit

018
018

0.217
0.326

1P+N

2P

* You can order this quantity or a multiple thereof.

5/20

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems
Cylindrical fuse sets and
cylindrical fuse holders
Number of
poles

In

For fuse links


of size

Mount- DT
ing
width

mm mm

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Cylindrical fuse holders without signal detector


3P
20
32

8 32
10 38

3
3

A
}

3NW7 333
3NW7 033

1
1

1 unit
1/4 units

018
018

0.194
0.194

50
100

14 51
22 58

4.5
6

}
}

3NW7 131
3NW7 231

1
1

1 unit
1 unit

018
018

0.324
0.488

20
32

8 32
10 38

3
3

A
}

3NW7 363
3NW7 063

1
1

1 unit
1 unit

018
018

0.208
0.205

50
100

14 51
22 58

6
8

A
A

3NW7 161
3NW7 261

1
1

1 unit
1 unit

018
018

0.452
0.685

B
B

3NW7 901
3NW7 902

1
1

1 unit
1 unit

018
018

0.048
0.048

3NW7 903

1 unit

018

0.034

3P+N

Auxiliary switches
For indicating disconnection of the fuse link, solely for
application of striker fuse links.
For retrofitting using the factory-fitted brackets.
Contact: 250 V AC, 5 A,
Minimum contact load: 12 V, 25 mA
For fuse bases
For fuse bases

14 51
22 58

0.5

For indicating the switching state of the fuse holder.


For retrofitting using the factory-fitted brackets.
Contact: 230 V AC, 6 A/110 V DC, 1 A
Minimum contact load: 12 V, 25 mA
Terminals 1.5 mm - 0.5 Nm
For fuse holders

10 38

0.5

More information
Mounting
Fuse holders, sizes 8 mm x 32 mm and 10 mm x 38 mm, have a
sliding catch that enables the removal of individual devices from
the assembly.
The infeed can be from the top or the bottom. Because the cylindrical fuse holders are fitted with the same anti-slip terminals at
the top and the bottom, the devices can also be rail-mounted at
the top or the bottom.
Auxiliary switches
Auxiliary switches are available for the cylindrical fuse holders.
These are simply clipped onto the base using the factory-fitted
brackets.
Sizes 8 mm 32 mm and 10 mm 38 mm:
The auxiliary switches support the remote display of the switching state ON or OFF of the fuse holder.
Sizes 14 mm 51 mm and 22 mm 58 mm:
The auxiliary switches support the remote display of fuse failure.
However, fuse links with strikers are required for this function.
When the fuse is tripped, a small striking pin - the striker - shoots
out of the front of the fuse. Over an armature link in the auxiliary
switch, the kinetic energy of this striker is used to switch a mini
switch, which then initializes this signal over a floating contact.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/21

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems

Compact fuse holders for


motor starter combinations

Overview
Fused motor starter combinations can be configured with the
fuse holders. The contactor and the fuse holder can be mounted
directly next to each other.

The accessories are generally UL-certified.


Customers can mount an auxiliary switch which signals the
switching state or prevents the fuse holder from switching off
under load by interrupting the contactor control, thus increasing
safety for the operator and process.

The strong current-limiting fuses ensure a type 2 protection level


(coordination according to IEC 60947-4, no damage protection)
for the contactor.

The UL version has an SCCR value of 200 kA.

Busbars and a matching three-phase feeder terminals complete


the product range.

Cylindrical fuse holder Class CC with signal detector and mounted auxiliary switch

Installation configuration of a cylindrical fuse holder and a SIRIUS contactor on busbar adapter for the 60 mm busbar system.

Technical specifications
Cylindrical fuse holders
3NW7 0. .-1
mm mm 10 38

Sizes

3NW7 5. .-1HG
Class CC

Standards

IEC 60269; UL 512; CSA

UL 512; CSA

Approvals
Acc. to UL
Acc. to CSA

U, UL File Number E171267

u, UL File Number E171267


s

Rated voltage Un

V AC

690

600

Rated current In

A AC

32

30

Rated short-circuit strength

kA

120 (at 500 V)


80 (at 690 V)

200

AC-20B (switching without load)

--

Switching capacity
Utilization category
kV

Rated impulse withstand voltage

6
III

Overvoltage category

Pollution degree
Max. power dissipation of the fuse link

No-voltage changing of fuse links

Yes

Sealable when installed

Yes

Lockable with padlock

Yes

Mounting position

Any, but preferably vertical


Any

Current direction
Degree of protection

acc. to IEC 60529

IP20, with connected conductors


Yes

Terminals with touch protection according to BGV A3


at incoming and outgoing feeder
Ambient temperature

-5 ... +40, humidity 90 % at +20

Conductor cross-sections
Finely stranded, with end sleeve
AWG cables (American Wire Gauge)

mm2
AWG

1 ... 4
18 ... 10

Nm
lb. in

1.5
13
PZ2

Tightening torques
Terminal screws

5/22

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems

Compact fuse holders for


motor starter combinations
Auxiliary switches
3NW7 903-1

Standards

IEC 60947

Approvals

U, s, UL 508, UL File Number E334003

Utilization category
Rated voltage Un

V AC
V DC

Rated current In

AC-12

DC-13

250
--

-24

-120

-240

AC-15
24
--

120
--

240
--

Acc. to UL
240
--

0.5

0.25

1.5

Busbars
5ST2 60.
3NW7 0. .-1

For cylindrical fuse holders


Pin spacing

mm

3NW7 5. .-1HG

15

Standards

DIN EN 60974-1, VDE 0660 part 100, IEC 60947-1:2004, UL 508, CSA 22.2

Approvals

u, UL 4248-1, UL File Number E337131

Busbar material

E-Cu 58 F25
PA66-V0

Partition material
Lamp wire resistance /1.5 mm2

960
Overvoltage category III, degree of pollution 2

Insulation coordination
Rated voltage Un
Acc. to UL
Acc. to IEC

V AC
V AC

-690

600
--

Maximum busbar current In


Acc. to UL
Acc. to IEC

A
A

-80

65
--

Terminal
5ST2 600
3NW7 0. .-1

For cylindrical fuse holders


Pin spacing

mm

3NW7 5. .-1HG

15

Standards

IEC 60999:2000, UL 508

Approvals

u, UL 4248-1, UL File Number E337131


PA66-V0

Enclosure/cover material
Lamp wire resistance /1 mm2

960

Temperature resistance PA66-V0, HDT B ISO 179,


UL 94-V0/1.5

200
Overvoltage category III, degree of pollution 2

Insulation coordination
Max. operational voltage Umax
Acc. to UL
Acc. to IEC

V AC
V AC

-690

600
--

Maximum electrical load Imax


Acc. to UL
Acc. to IEC

A
A

-80

65
--

Rated current In

63

Conductor cross-sections
Solid/stranded
Finely stranded, with end sleeve

mm2
mm2

2.5 ... 35
2.5 ... 25

Tightening torque of clamping screw

Nm

2.5 ... 3.5

Siemens LV 10.1 2011

5/23

Siemens AG 2011

Fuse Systems
Cylindrical Fuse Systems

Compact fuse holders for


motor starter combinations

Selection and ordering data


Number of In
poles

For fuse links of size

Mount- DT
ing
width

mm x mm

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3NW7 cylindrical fuse holders


Cylindrical fuse holders U

3P
32
10 x 38
Without signal detectors
With signal detector

2.5
B
B

3NW7 033-1
3NW7 034-1

1
1

1 unit
1 unit

017
017

7.700
0.190

B
B

3NW7 533-1HG
3NW7 534-1HG

1
1

1 unit
1 unit

018
018

0.181
0.200

3NW7 903-1

1 unit

017

0.010

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Cylindrical fuse holders class CC u


3P
30
class CC
Without signal detectors
With signal detector

2.5

Accessories
Auxiliary switches u
AC-12, 5 A, max. 250 V, 1 NO, 1 NC

Version

2.5

In

Pin
spacing

Length

mm

mm

63

15

45
90
135
180

kg

Busbar system 5ST2 60.


Busbars u
2 x 3P
3 x 3P
4 x 3P
5 x 3P

B
B
B
B

5ST2 601
5ST2 602
5ST2 603
5ST2 604

1
1
1
1

10 units
10 units
10 units
10 units

027
027
027
027

0.450
0.705
0.950
1.230

5ST2 600

1 10 units

027

0.500

DT

Order No.

PG

Weight
per PU
approx.

Accessories
Terminals u
For conductor cross-section 2.5 mm2 ... 35 mm2

Length of
adapter

Width of
adapter

mm

mm

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

kg

Device adapters
Busbar device adapters1) with connecting cables
(above) u
Size S00,
rated voltage 690 V AC,
rated current 25 A,
1 mounting rail (35 mm),
connection cable AWG 12
200
260

45

}
}

8US12 51-5DS10
8US12 51-5DT10

1
1

1 unit
1 unit

143
143

0.183
0.183

8US19 98-7CB45

1 10 units

143

0.009

Accessories
Mounting rails for busbar device adapter u
For assembly of additional devices

1)

45

Further device adapters and accessories, see chapter "Busbar Systems".

* You can order this quantity or a multiple thereof.

5/24

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Class CC fuse systems

Overview

Benefits
For switchgear and machine manufacturers who export their
systems. Compliance with the American standard is kept.
Approved according to UL and CSA for typical "branch circuit
protection" applications. This facilitates export.
Modern design with touch protection to BGV A3 ensures safe
installation.

Class CC fuses are used for "branch circuit protection".


The enclosed fuse holders are designed and tested to comply
with the US National Electrical Code NEC 210.20(A). This means
that when subject to continuous operation, only 80 % of the rated
current is permissible as operational current.
An operational current of 100 % of the rated current (30 A) is only
permissible short-time.

The devices are prepared for the inscription labels of the


ALPHA FIX terminal blocks 8WH8 120-7AA15 and
8WH8 120-7XA05.
There are three different series:
Characteristic: slow 3NW1 ...-0HG
For the protection of control transformers, reactors, inductances. Significantly slower than the minimum requirements
specified by UL for Class CC Fuses of 12 s at 2 In.
Characteristic: quick 3NW2 ...-0HG
For a wide range of applications, for the protection of lighting
installations, heating, control systems.
Characteristic: slow, current-limiting, 3NW3 ...-0HG
Slow for overloads and quick for short circuits. High current
limitation for the protection of motor circuits.
Note:
Compact fuse holders for motor starter combinations Class CC
can be found on page 5/24.

Technical specifications
Class CC fuse holders
3NW7 5.3-0HG
UL 512; CSA C22.2
UL 512; UL File No. E171267; CSA C22.2

Standards
Approvals
Rated voltage

V AC

600

Rated current In

30

Max. power dissipation of fuse links


With cable, 6 mm2
With cable, 10 mm2

W
W

3
4.3

Conductor cross-sections
Solid and stranded
AWG Conductor cross-section, solid and stranded

mm2
AWG

1.5 ... 25
18 ... 4
Class CC fuse links
3NW1...-0HG

Characteristic
Rated voltage

V AC

3NW3 ...-0HG

Slow

Quick

Slow, current limiting

600

600

600

V DC
Rated breaking capacity

3NW2 ...-0HG

UL 248-4; CSA C22.2


UL 248-4; UL File Number E258218; CSA C22.2

Standards
Approvals

kA AC

150 (3 .... 15 A)
300 (< 3 A, > 15 A)
200

Siemens LV 10.1 2011

5/25

Siemens AG 2011

Fuse Systems
Class CC fuse systems

Selection and ordering data


Number of
poles

Un

In

Mount- DT
ing
width

MW

30
30
30

1
2
3

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Class CC fuse holders


1P
2P
3P

600
600
600

C
C
C

Characteristic: slow
In1)

DT

Order No.

1 12 units
1
6 units
1
4 units

3NW7 513-0HG
3NW7 523-0HG
3NW7 533-0HG

018
018
018

0.069
0.139
0.208

PG

Weight
per PU
approx.

Characteristic: quick
Price PG
per PU

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

kg

A
Class CC fuse links
0.6 (6/10)
0.8 (8/10)
1
1.5 (1 )

C
C
C
C

3NW1 006-0HG
3NW1 008-0HG
3NW1 010-0HG
3NW1 015-0HG

018
018
018
018

--3NW2 010-0HG
--

1
1
1
1

10 units
10 units
10 units
10 units

2
3
4
5

C
C
C
C

3NW1 020-0HG
3NW1 030-0HG
3NW1 040-0HG
3NW1 050-0HG

018
018
018
018

C
C
C
C

3NW2 020-0HG
3NW2 030-0HG
3NW2 040-0HG
3NW2 050-0HG

1
1
1
1

10 units
10 units
10 units
10 units

018
018
018
018

0.008
0.005
0.009
0.010

6
8
10
12

C
C
C

3NW1 060-0HG
3NW1 080-0HG
3NW1 100-0HG
--

018
018
018

C
C
C
C

3NW2 060-0HG
3NW2 080-0HG
3NW2 100-0HG
3NW2 120-0HG

1
1
1
1

10 units
10 units
10 units
10 units

018
018
018
018

0.009
0.008
0.008
0.010

15
20
25
30

C
C
C
C

3NW1 150-0HG
3NW1 200-0HG
3NW1 250-0HG
3NW1 300-0HG

018
018
018
018

C
C
C

3NW2 150-0HG
3NW2 200-0HG
3NW2 250-0HG
--

1
1
1
1

10 units
10 units
10 units
10 units

018
018
018

0.010
0.009
0.012
0.002

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

018

0.009
0.011
0.008
0.010

Characteristic: slow,
current limiting
In1)

DT

Order No.

kg

A
Class CC fuse links
0.6 (6/10)
0.8 (8/10)
1
1.5 (1 )

1)

--3NW3 010-0HG
--

1 10 units

018

0.017

2
3
4
5

C
C
C
C

3NW3 020-0HG
3NW3 030-0HG
3NW3 040-0HG
3NW3 050-0HG

1
1
1
1

10 units
10 units
10 units
10 units

018
018
018
018

0.017
0.009
0.008
0.009

6
8
10
12

C
C
C
C

3NW3 060-0HG
3NW3 080-0HG
3NW3 100-0HG
3NW3 120-0HG

1
1
1
1

10 units
10 units
10 units
10 units

018
018
018
018

0.009
0.009
0.001
0.008

15
20
25
30

C
C
C
C

3NW3 150-0HG
3NW3 200-0HG
3NW3 250-0HG
3NW3 300-0HG

1
1
1
1

10 units
10 units
10 units
10 units

018
018
018
018

0.008
0.007
0.006
0.008

Values in brackets, American English Wording

* You can order this quantity or a multiple thereof.

5/26

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Busbar systems

Overview
Busbars with pin-type connections can be used for NEOZED
safety switching devices and fuse bases. Busbars in 10 mm2
and 16 mm2 versions are available.

Busbars with fork plugs are used for the most frequently used
NEOZED fuse bases made of ceramic.

Benefits

Clear and visible conductor connection that can be easily


checked when using NEOZED comfort base D02. This facilitates cable entry and saves time.

Bus-mounting of NEOZED fuse bases made of molded plastic


on three-phase busbar with fork plug, which can be cut to
length. Frequently used.

Bus-mounting of NEOZED fuse bases made of ceramic on


three-phase busbar with fork plug, which can be cut to length.
Most common application.

Bus-mounting of MINIZED fuse switch disconnectors D01 with


three-phase pin busbar, which can be cut to length with fork
plug. Tried and tested.

Clear and visible conductor connection that can be easily


checked when using MINIZED switch disconnectors D02.
This facilitates cable entry and saves time.

Bus-mounting of cylindrical fuse holders 8 mm 32 mm and


10 mm 38 mm with three-phase pin busbar which can be
cut to length.

Siemens LV 10.1 2011

5/27

Siemens AG 2011

Fuse Systems
Busbar systems

5
Bus-mounting of SITOR cylindrical fuse holders
10 mm x 38 mm with the same terminal connection as
Class CC fuse holders with three-phase pin busbar which can
be cut to length.

Bus mounting with infeed through a connection terminal


directly on the fuse holder up to a conductor cross-section of
35 mm

Technical specifications
5ST, 5SH
Standards

EN 60439-1: 2005-01

Busbar material

SF-Cu F 24

Partition material

Plastic, Cycoloy 3600


heat-resistant over 90 C
flame-retardant and
self-extinguishing,
dioxin and halogen-free
V AC

400

Cross-section 10 mm2
Cross-section 16 mm2

A
A

63
80

Rated impulse withstand voltage Uimp

kV

Test pulse voltage (1.2/50)

kV

6.2

Rated conditional short-circuit current Icc

kA

25

Rated operational voltage Uc


Rated current In

Resistance to climate
Constant atmosphere
Humid heat

Acc. to DIN 50015


Acc. to IEC 60068-2-30

23/83; 40/92; 55/20


28 cycles

Insulation coordination
Overvoltage category
Pollution degree

III
2

Maximum busbar current IS/phase


Infeed at the start of the busbar
- Cross-section 10 mm2
- Cross-section 16 mm2

A
A

63
80

Infeed at the center of the busbar


- Cross-section 10 mm2
- Cross-section 16 mm2

A
A

100
130

5/28

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Busbar systems
5ST3 7 . . - . HG busbars acc. to UL 508
5ST3 7. .-0HG

5ST3 7. .-2HG

Standards

UL 508, CSA C22.2 No. 14-M 95

Approvals

UL 508 File No. E328403


CSA

5ST3 770-0HG

5ST3 770-1HG

Operational voltage
Acc. to IEC
Acc. to UL 489

V AC
V AC

690
600

Rated conditional short-circuit current

kA

10 (RMS symmetrical 600 V for three cycles)

Dielectric strength
Surge strength

kV/mm
kV

25
> 9.5

Rated current

--

--

115

A
A

80
160

100
200

---

---

25

--

--

Maximum busbar current IS/phase


Infeed at the start of the busbar
Infeed at the center of the busbar
Insulation coordination
Overvoltage category
Pollution degree

III
2

Busbar cross-section

mm2 Cu 18
Any

Infeed
Conductor cross-sections

AWG
mm2

---

---

10 ... 1/0
6 ... 35

14 ... 1
1.5 ... 50

Nm
lbs/in

---

---

5
50

3.5
35

Terminals
Terminal tightening torque

Infeed at the start of the busbar

Infeed along the busbar or midpoint infeed


3

3
I201_13754a

I201_13755

The sum of the output current per branch must not be greater than the busbar current IS1.2 / phase.

Selection and ordering data


Phases

Conductor Load
crosscapacity
section
up to

Pin
spacing

Length

mm2

MW

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Busbars
For MINIZED switch disconnectors D02
For NEOZED comfort bases D01/D02
Made of molded plastic
5SG1 301, 5SG1 701, 5SG5 301, 5SG5 701
For NEOZED fuse bases D01/D02
Made of ceramic
Terminal version S (saddle terminal)
For cylindrical fuse holder 14 mm 51 mm
For cylindrical fuse holder SITOR 14 mm 51 mm
Can be cut to length, without end caps
Singlephase

16

130

1.5

1016

5ST3 703

1 unit

027

0.185

Threephase

16

120

1.5

1016

5ST3 714

1 unit

027

0.540

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/29

Siemens AG 2011

Fuse Systems
Busbar systems
Phases

Conductor Load
crosscapacity
section
up to

Pin
spacing

Length

mm2

MW

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For MINIZED fuse switch disconnectors D01


Can be cut to length, without end caps
Singlephase
Twophase
Threephase

16

120

1000

5ST2 190

1 unit

027

0.222

5ST2 191

1 unit

027

0.448

5ST2 192

1 unit

027

0.582

5ST2 186

1 unit

027

0.048

5ST2 187

1 unit

027

0.092

5ST2 188

1 unit

027

0.110

5SH5 321

1 unit

016

0.169

5SH5 322

1 unit

016

0.260

Can be cut to length, with 2 end caps


Singlephase
Twophase
Threephase

16

120

220

For NEOZED fuse bases D01/D02 made of molded plastic


5SG1 .30, 5SG1 .31, 5SG5 .30
For NEOZED fuse bases D01/D02 made of ceramic,
terminal version B and K (clamp-type terminal, screw head
contact)
Non-insulated
Singlephase

20

116

1.5

36

168

1.5

1000

Can be cut to length, without end caps


Singlephase

24

160

1.5

1000

5SH5 517

1 unit

016

0.342

Threephase

16

120

1.5

1000

5SH5 320

1 unit

016

0.562

5ST3 701

1 unit

027

0.196

5ST3 705

1 unit

027

0.452

1016

5ST3 710

1 unit

027

0.610

214

5ST3 700

1 unit

027

0.039

5ST3 704

1 unit

027

0.092

5ST3 708

1 unit

027

0.116

For cylindrical fuse holder 8 mm 32 mm and


10 mm 38 mm
For cylindrical fuse holder SITOR 10 mm 38 mm
For class CC fuse holder
Can be cut to length, without end caps
Singlephase
Twophase

16

Threephase

16

120

120

120

1016

Cannot be cut to length, fully insulated


Singlephase
Twophase
Threephase

16

End caps for busbars


For single-phase 5ST2 190 busbars

5ST2 196

1 10 units

027

0.001

For two-phase 5ST2 191 busbars and


for three-phase 5ST2 192 busbars

5ST2 197

1 10 units

027

0.001

For single-phase 5ST3 7, 5SH5 5 busbars

5ST3 748

1 10 units

027

0.001

For two-phase and three-phase 5ST3 7 busbars and


for three-phase 5SH5 320 busbars

5ST3 750

1 10 units

027

0.001

* You can order this quantity or a multiple thereof.

5/30

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
Busbar systems
Phases

Conductor Load capacity


crossup to
section

Length

mm2

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Touch protection for free connection of


pin busbars
Yellow, (RAL1004)
5 x 1 pin

5ST3 655

10 units

027

0.003

Terminals
For NEOZED fuse bases D01/D02 made of ceramic
For DIAZED fuse bases DII/DIII made of ceramic
Terminal version S
For con- 2 ... 25
ductors

5SH5 327

10/300 units

016

0.011

Terminal versions B and K


For con- 6 ... 25
ductors

5SH5 328

10/300 units

016

0.016

For the infeed of fork-type or pin busbars


For con- 6 ... 35
ductors

5ST2 157

5 units

027

0.028

Busbars
For 1-pole DIAZED fuse bases made of ceramic
with terminal versions BB and BS
Size DII, for 19 bases
Single24
phase

80

1000

5SH3 500

1/25 units

016

0.120

Size DIII, for 25 bases


Single39
120
phase

1000

5SH3 501

1/25 units

016

0.200

For size DII, 42 5SF6 005 bases


Single48
150
phase

2000

5SH3 54

5 units

016

0.700

For size DIII, 34 5SF6 205 bases


Single48
150
phase

2000

5SH3 55

5 units

016

0.750

1.5 ... 16

8JH4 122

10 units

046

0.009

10 ... 35

8JH4 124

10 units

046

0.023

Busbars
For DIAZED bus-mounting bases/EZR
with thread for screw adapters

Bus-mounting terminals
For DIAZED EZR bus-mounting bases
Non-insulated
For conductors
For conductors

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/31

Siemens AG 2011

Fuse Systems
Busbar systems
5ST3 7 . . - . HG busbars acc. to UL 508
Pin
spacing

Length

MW

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

5ST3 7. .-.HG busbars according to UL 508, 18 mm2,


can be cut, without end caps
Single-phase

For fuse holders 10 x 38


class CC (3NC1 091,
3NW7 513-0HG) or MCB 1P (5SY)

1000

5ST3 701-0HG

1 10 units

012

0.330

For fuse holders 14 x 51


(3NC1 491, 3NW7 111) or
MCB 1P (5SY, 5SP) with AS or FC

1.5

1000

5ST3 703-0HG

1 10 units

012

0.330

1000

5ST3 705-0HG

1 10 units

012

0.700

For fuse holder 10 x 38/class CC


(3NC1 093, 3NW7 533-0HG) or
MCB 3P (5SY)

1000

5ST3 710-0HG

1 10 units

012

0.850

For fuse holders 14 x 51


(3NC1 493, 3NW7 131) or
MCB 1P (5SY, 5SP) with AS or FC

1.5

1000

5ST3 714-0HG

1 10 units

012

0.850

Two-phase
For fuse holder 10 x 38/class CC
(3NC1 092, 3NW7 523-0HG) or
MCB 2P (5SY)
Three-phase

5ST3 7. .-.HG busbars according to UL 508, 25 mm2,


can be cut, without end caps
Single-phase
For fuse holders 14 x 51
(3NC1 491, 3NW7 111) or
MCB 1P (5SP)

1.5

1000

5ST3 701-2HG

1 10 units

012

0.340

1.5

1000

5ST3 705-2HG

1 10 units

012

0.800

1.5

1000

5ST3 710-2HG

1 10 units

012

1.090

For single-phase busbars

5ST3 748-0HG

1 10 units

012

0.001

For two- and three-phase busbars

5ST3 750-0HG

1 10 units

012

0.002

5ST3 770-0HG

1 10 units

012

0.035

5ST3 770-1HG

1 10 units

012

0.035

5ST3 655-0HG

1 10 units

012

0.005

Two-phase
For fuse holder 14 x 51
(3NC1 492, 3NW7 121) or
MCB 2P (5SP)
Three-phase
For fuse holder 14 x 51
(3NC1 493, 3NW7 131) or
MCB 3P (5SP)
End caps for 5ST3 7. .-.HG

Terminals according to UL 508


Infeed to device
35 mm2

Infeed to busbar
50 mm2
Touch protection cover for busbars
according to UL 508
5 x 1 pin

* You can order this quantity or a multiple thereof.

5/32

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links

Overview
LV HRC fuse systems (NH type) are used for installation systems
in non-residential, commercial and industrial buildings as well as
in systems of power supply companies. They therefore protect
essential building parts and installations.
LV HRC fuse systems (NH type) are fuse systems designed for
operation by experts. There are no constructional requirements
for non-interchangeability of rated current and touch protection.
The components and auxiliary equipment are designed in such
a way as to ensure the safe replacement of NH type fuses or isolation of systems.
LV HRC fuse links are available in the sizes 000, 00, 0, 1, 2, 3, 4
and 4a.

LV HRC fuse links are available in the following operational


classes:
gG for cable and line protection
aM for the short-circuit protection of switching devices in
motor circuits
gR or aR for the protection of power semiconductors
gS: The new operational class gS combines cable and line
protection with semiconductor protection.
LV HRC fuse links of size 000 can also be used in
LV HRC fuse bases, LV HRC fuse switch disconnectors,
LV HRC fuse strips as well as LV HRC in-line fuse switch disconnectors of size 00.
The fuse links 300 A, 355 A and 425 A comply with the standard
but do not have the VDE mark.

LV HRC components

2
6
7

8
1
9

14
10

15
I2_13743

11

16

12

17

13

18

19

$
%
&
(
)
*
+
,
.
/
0
1
2
3
4
5
6
7

LV HRC fuse base from the SR60 busbar system


LV HRC fuse base for busbar mounting
LV HRC fuse base, 3P
LV HRC fuse base, 1P
LV HRC contact cover
LV HRC fuse link
LV HRC signal detector
LV HRC partition
LV HRC protective cover
LV HRC fuse base with swivel mechanism
- For screw fixing on mounting plates
- For screw fixing on busbar systems
- For claw fixing on busbars
LV HRC protective cover for LV HRC fuse bases with swivel
mechanism
LV HRC swivel mechanism
LV HRC fuse base cover
LV HRC isolating link with insulated grip lugs
LV HRC isolating link with non-insulated grip lugs
LV HRC fuse puller with sleeve
LV HRC fuse puller

Siemens LV 10.1 2011

5/33

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links

Benefits

Tripped

Not tripped

Tripped

LV HRC fuse links with combination alarm signal the tripping


of a fuse by a clear color change from red to white. This enables fast identification and replacement of the tripped fuse
links. This increases plant availability
The insulated grip lugs made of metal are integrated in the top
and bottom covers of the fuse link in molded plastic and provide greater safety during replacement. The mark shown
below indicates that the grip lugs are insulated

Not tripped

In the standard series with front indicator, the front-mounted


red indicator signals the tripping of a fuse.
LV HRC fuse links are always equipped with silver-plated contact pins. This means that they are non-corroding and have
less contact resistance. This ensures the long-term operational safety of the plant.

Technical specifications
LV HRC fuse links
Operational class

Operational
class

gG

aM

3NA6 ...-4
3NA6 ...-4KK
3NA3 83.-8

3NA6 ...
3NA6 ...-7
3NA7 ...
3NA7 ...-7

3NA3 ...
3NA3 ...-7

3NA6 ...-6
3NA7 ...-6

3NA3 ...-6

3ND1
3ND2

IEC 60269-1, -2; EN 60269-1; DIN VDE 0636


DIN VDE 0636-2; CSA 22.2 No.106, File Number 016325_0_00 (CSA approval of fuses 500 V for 600 V)

Standards
Approvals
Rated voltage Un
Sizes 000 and 00
Sizes 1 and 2
Size 3
Sizes 4 and 4a (IEC design)

V AC

400

500

500

690

690

500

V DC

--

250

250

250

250

--

V AC

400

500

500

690

690

690

V DC

--

440

440

440

440

-690

V AC

500

690

V DC

440

440

V AC

500

--

V DC

400

Rated current In

10 ... 400

Rated breaking capacity

kA AC

120

kA DC

--

25

Non-corroding, silver-plated

Contact pins
Resistance to climate

5/34

2 ... 400

Siemens LV 10.1 2011

-20 ... +50 at 95 % relative humidity

2 ... 1250

-2 ... 315

2 ... 500

6 ... 630
--

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links

Selection and ordering data


Insulated grip lugs
Sizes

Mounting
width

In

Un

mm

V AC/V DC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with combination alarm,


operational class gG
000

00

21

B
B
B

3NA6 803-4
3NA6 805-4
3NA6 807-4

1 3 units
1 3 units
1 3 units

013
013
013

0.127
0.128
0.128

25
32
35

B
B
B

3NA6 810-4
3NA6 812-4
3NA6 814-4

1 3 units
1 3 units
1 3 units

013
013
013

0.128
0.128
0.123

40
50
63

B
B
B

3NA6 817-4
3NA6 820-4
3NA6 822-4

1 3 units
1 3 units
1 3 units

013
013
013

0.113
0.125
0.126

80
100

B
B

3NA6 824-4
3NA6 830-4

1 3 units
1 3 units

013
013

0.124
0.120

B
B

3NA6 824-4KK
3NA6 830-4KK

1 3 units
1 3 units

013
013

0.201
0.204

B
B

3NA6 832-4
3NA6 836-4

1 3 units
1 3 units

013
013

0.193
0.206

B
B
B

3NA6 114-4
3NA6 117-4
3NA6 120-4

1 3 units
1 3 units
1 3 units

013
013
013

0.293
0.290
0.287

63
80
100

B
B
B

3NA6 122-4
3NA6 124-4
3NA6 130-4

1 3 units
1 3 units
1 3 units

013
013
013

0.294
0.288
0.278

125
160

B
B

3NA6 132-4
3NA6 136-4

1 3 units
1 3 units

013
013

0.276
0.295

47.2

200
224
250

B
B
B

3NA6 140-4
3NA6 142-4
3NA6 144-4

1 3 units
1 3 units
1 3 units

013
013
013

0.421
0.442
0.420

47.2

50
63
80

B
B
B

3NA6 220-4
3NA6 222-4
3NA6 224-4

1 3 units
1 3 units
1 3 units

013
013
013

0.460
0.461
0.460

100
125
160

B
B
B

3NA6 230-4
3NA6 232-4
3NA6 236-4

1 3 units
1 3 units
1 3 units

013
013
013

0.461
0.457
0.463

200
224
250

B
B
B

3NA6 240-4
3NA6 242-4
3NA6 244-4

1 3 units
1 3 units
1 3 units

013
013
013

0.462
0.441
0.464

300
315
355
400

B
B
B
B

3NA6 250-4
3NA6 252-4
3NA6 254-4
3NA6 260-4

1
1
1
1

013
013
013
013

0.666
0.619
0.660
0.662

30

10
16
20

80
100

400/--

400/--

125
160

30

57.8

35
40
50

400/--

400/--

3 units
3 units
3 units
3 units

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/35

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links
Non-insulated
grip lugs
Size

Mount- In
ing
width

Un

mm

V AC/
V DC

DT

Order No.

Insulated grip lugs


Price PG
per PU

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with


combination alarm,
operational class gG

000

00

21

30

30

47.2

47.2

57.8

2 500/
4 250
6

B
B
B

3NA7 802
3NA7 804
3NA7 801

013
013
013

B
B
B

3NA6 802
3NA6 804
3NA6 801

1 3 units
1 3 units
1 3 units

013
013
013

0.130
0.126
0.116

10
16
20

B
}
}

3NA7 803
3NA7 805
3NA7 807

013
013
013

B
}
}

3NA6 803
3NA6 805
3NA6 807

1 3 units
1 3 units
1 3 units

013
013
013

0.128
0.129
0.128

25
32
35

}
B
}

3NA7 810
3NA7 812
3NA7 814

013
013
013

}
B
}

3NA6 810
3NA6 812
3NA6 814

1 3 units
1 3 units
1 3 units

013
013
013

0.121
0.129
0.129

40
50
63

B
}
}

3NA7 817
3NA7 820
3NA7 822

013
013
013

B
}
}

3NA6 817
3NA6 820
3NA6 822

1 3 units
1 3 units
1 3 units

013
013
013

0.123
0.124
0.125

80
100

}
}

3NA7 824
3NA7 830

013
013

}
}

3NA6 824
3NA6 830

1 3 units
1 3 units

013
013

0.128
0.124

80 500/
100 250
125

B
B
}

3NA7 824-7
3NA7 830-7
3NA7 832

013
013
013

B
B
}

3NA6 824-7
3NA6 830-7
3NA6 832

1 3 units
1 3 units
1 3 units

013
013
013

0.182
0.202
0.206

160

3NA7 836

013

3NA6 836

1 3 units

013

0.194

16 500/
20 440
25

B
B
B

3NA7 105
3NA7 107
3NA7 110

013
013
013

B
B
B

3NA6 105
3NA6 107
3NA6 110

1 3 units
1 3 units
1 3 units

013
013
013

0.305
0.286
0.290

35
40
50

B
B
B

3NA7 114
3NA7 117
3NA7 120

013
013
013

B
B
B

3NA6 114
3NA6 117
3NA6 120

1 3 units
1 3 units
1 3 units

013
013
013

0.284
0.295
0.288

63
80
100

B
B
B

3NA7 122
3NA7 124
3NA7 130

013
013
013

B
}
}

3NA6 122
3NA6 124
3NA6 130

1 3 units
1 3 units
1 3 units

013
013
013

0.281
0.289
0.290

125
160

}
}

3NA7 132
3NA7 136

013
013

}
}

3NA6 132
3NA6 136

1 3 units
1 3 units

013
013

0.292
0.283

200
224
250

}
B
}

3NA7 140
3NA7 142
3NA7 144

013
013
013

}
B
}

3NA6 140
3NA6 142
3NA6 144

1 3 units
1 3 units
1 3 units

013
013
013

0.442
0.439
0.419

B
B
B

3NA7 214
3NA7 220
3NA7 222

013
013
013

B
B
B

3NA6 214
3NA6 220
3NA6 222

1 3 units
1 3 units
1 3 units

013
013
013

0.435
0.435
0.460

80
100
125

B
B
B

3NA7 224
3NA7 230
3NA7 232

013
013
013

B
B
B

3NA6 224
3NA6 230
3NA6 232

1 3 units
1 3 units
1 3 units

013
013
013

0.459
0.434
0.463

160
200

}
}

3NA7 236
3NA7 240

013
013

}
}

3NA6 236
3NA6 240

1 3 units
1 3 units

013
013

0.462
0.437

224
250

B
}

3NA7 242
3NA7 244

013
013

B
}

3NA6 242
3NA6 244

1 3 units
1 3 units

013
013

0.462
0.463

300
315

-3NA7 252

013

B
}

3NA6 250
3NA6 252

1 3 units
1 3 units

013
013

0.656
0.627

355
400

-3NA7 260

013

B
}

3NA6 254
3NA6 260

1 3 units
1 3 units

013
013

0.657
0.659

35 500/
50 440
63

* You can order this quantity or a multiple thereof.

5/36

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links
Non-insulated
grip lugs
Sizes

Mounting
width

In

Un

mm

V AC/V DC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with front indicator,


operational class gG
000

00

21

30

30

30

47.2

}
}
}

3NA3 802
3NA3 804
3NA3 801

1
1
1

3 units
3 units
3 units

013
013
013

0.122
0.125
0.121

10
16
20

}
}
}

3NA3 803
3NA3 805
3NA3 807

1
1
1

3 units
3 units
3 units

013
013
013

0.130
0.123
0.120

25
32
35

}
}
}

3NA3 810
3NA3 812
3NA3 814

1
1
1

3 units
3 units
3/90 units

013
013
013

0.123
0.124
0.129

40
50
63

}
}
}

3NA3 817
3NA3 820
3NA3 822

1
1
1

3 units
3/90 units
3/90 units

013
013
013

0.127
0.122
0.124

80
100

}
}

3NA3 824
3NA3 830

1
1

3/90 units
3/90 units

013
013

0.128
0.124

2
4
6

500/250

125
160

400/250

}
}

3NA3 832-8
3NA3 836-8

1
1

3/60 units
3/60 units

013
013

0.120
0.160

35
50
63

500/250

B
B
B

3NA3 814-7
3NA3 820-7
3NA3 822-7

1
1
1

3 units
3 units
3 units

013
013
013

0.190
0.189
0.190

80
100
125

B
B
}

3NA3 824-7
3NA3 830-7
3NA3 832

1
1
1

3 units
3 units
3 units

013
013
013

0.198
0.191
0.192

160

3NA3 836

3 units

013

0.189

B
B
B

3NA3 001
3NA3 003
3NA3 005

1
1
1

3 units
3 units
3 units

013
013
013

0.266
0.244
0.255

20
25
32

B
B
B

3NA3 007
3NA3 010
3NA3 012

1
1
1

3 units
3 units
3 units

013
013
013

0.253
0.258
0.270

35
40
50

B
B
B

3NA3 014
3NA3 017
3NA3 020

1
1
1

3 units
3 units
3 units

013
013
013

0.271
0.253
0.266

63
80
100

A
B
A

3NA3 022
3NA3 024
3NA3 030

1
1
1

3 units
3 units
3 units

013
013
013

0.271
0.256
0.260

125
160

A
A

3NA3 032
3NA3 036

1
1

3 units
3 units

013
013

0.259
0.272

B
B
B

3NA3 105
3NA3 107
3NA3 110

1
1
1

3 units
3 units
3 units

013
013
013

0.283
0.285
0.275

35
40
50

B
B
B

3NA3 114
3NA3 117
3NA3 120

1
1
1

3 units
3 units
3 units

013
013
013

0.283
0.275
0.280

63
80
100

}
}
}

3NA3 122
3NA3 124
3NA3 130

1
1
1

3 units
3 units
3 units

013
013
013

0.284
0.269
0.270

125
160

}
}

3NA3 132
3NA3 136

1
1

3 units
3 units

013
013

0.271
0.290

200
224
250

}
A
}

3NA3 140
3NA3 142
3NA3 144

1
1
1

3 units
3 units
3 units

013
013
013

0.412
0.411
0.447

6
10
16

16
20
25

500/440

500/440

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/37

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links
Non-insulated
grip lugs
Sizes

Mounting
width

In

Un

mm

V AC/V DC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with front indicator,


operational class gG

47.2

57.8

57.8

71.2

35
50
63

B
B
A

3NA3 214
3NA3 220
3NA3 222

1 3 units
1 3 units
1 3 units

013
013
013

0.454
0.420
0.433

80
100
125

A
A
A

3NA3 224
3NA3 230
3NA3 232

1 3 units
1 3 units
1 3 units

013
013
013

0.431
0.430
0.429

160
200

}
}

3NA3 236
3NA3 240

1 3 units
1 3 units

013
013

0.432
0.427

224
250

}
}

3NA3 242
3NA3 244

1 3 units
1 3 units

013
013

0.432
0.440

300
315

A
}

3NA3 250
3NA3 252

1 3 units
1 3 units

013
013

0.626
0.625

355
400

}
}

3NA3 254
3NA3 260

1 3 units
1 3 units

013
013

0.617
0.624

B
B
A

3NA3 340
3NA3 342
3NA3 344

1 3 units
1 3 units
1 3 units

013
013
013

0.629
0.625
0.632

300
315

B
}

3NA3 350
3NA3 352

1 3 units
1 3 units

013
013

0.626
0.632

355
400

A
}

3NA3 354
3NA3 360

1 3 units
1 3 units

013
013

0.666
0.677

425
500
630

A
}
}

3NA3 362
3NA3 365
3NA3 372

1 3 units
1 3 units
1 3 units

013
013
013

0.892
0.880
0.885

B
A
A

3NA3 472
3NA3 475
3NA3 480

1
1
1

1 unit
1 unit
1 unit

013
013
013

2.577
2.580
2.584

3NA3 482

1 unit

013

2.608

B
B
A

3NA3 665
3NA3 672
3NA3 675

1
1
1

1 unit
1 unit
1 unit

013
013
013

2.692
2.694
2.707

A
A

3NA3 680
3NA3 682

1
1

1 unit
1 unit

013
013

2.708
2.748

200
224
250

500/440

500/440

Can only be used for 3NH3 530 LV HRC fuse base


4 (IEC design) 101.8

630
800
1000

500/440

1250

Can only be used for 3NH7 520 LV HRC fuse base or


for 3NJ56 43-0BB00 fuse switch disconnector with inline design
4a

101.8

500
630
800
1000
1250

500/440

* You can order this quantity or a multiple thereof.

5/38

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links
Non-insulated
grip lugs
Size

Mount- In
ing
width

Un

mm

V AC/
V DC

DT

Order No.

Insulated grip lugs


Price
per PU

PG

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with


combination alarm,
operational class gG
000

00

21

B
B
B

3NA7 802-6
3NA7 804-6
3NA7 801-6

013
013
013

B
B
B

3NA6 802-6
3NA6 804-6
3NA6 801-6

1 3 units
1 3 units
1 3 units

013
013
013

0.122
0.130
0.122

10
16
20

B
B
B

3NA7 803-6
3NA7 805-6
3NA7 807-6

013
013
013

B
B
B

3NA6 803-6
3NA6 805-6
3NA6 807-6

1 3 units
1 3 units
1 3 units

013
013
013

0.124
0.123
0.128

25
32
35

B
B
B

3NA7 810-6
3NA7 812-6
3NA7 814-6

013
013
013

B
B
B

3NA6 810-6
3NA6 812-6
3NA6 814-6

1 3 units
1 3 units
1 3 units

013
013
013

0.120
0.128
0.129

40 690/
50 250
63

B
B
B

3NA7 817-6
3NA7 820-6
3NA7 822-6

013
013
013

B
B
B

3NA6 817-6
3NA6 820-6
3NA6 822-6

1 3 units
1 3 units
1 3 units

013
013
013

0.203
0.196
0.202

B
B

3NA7 824-6
3NA7 830-6

013
013

B
B

3NA6 824-6
3NA6 830-6

1 3 units
1 3 units

013
013

0.187
0.202

B
B
B

3NA7 120-6
3NA7 122-6
3NA7 124-6

013
013
013

B
B
B

3NA6 120-6
3NA6 122-6
3NA6 124-6

1 3 units
1 3 units
1 3 units

013
013
013

0.271
0.280
0.284

100
125
160

B
B
B

3NA7 130-6
3NA7 132-6
3NA7 136-6

013
013
013

B
B
B

3NA6 130-6
3NA6 132-6
3NA6 136-6

1 3 units
1 3 units
1 3 units

013
013
013

0.291
0.282
0.293

47.2

200

3NA7 140-6

013

3NA6 140-6

1 3 units

013

0.439

47.2

80 690/
100 440
125

B
B
B

3NA7 224-6
3NA7 230-6
3NA7 232-6

013
013
013

B
B
B

3NA6 224-6
3NA6 230-6
3NA6 232-6

1 3 units
1 3 units
1 3 units

013
013
013

0.460
0.462
0.436

160
200

B
B

3NA7 236-6
3NA7 240-6

013
013

B
B

3NA6 236-6
3NA6 240-6

1 3 units
1 3 units

013
013

0.439
0.455

224
250

B
B

3NA7 242-6
3NA7 244-6

013
013

B
B

3NA6 242-6
3NA6 244-6

1 3 units
1 3 units

013
013

0.656
0.658

300
315

B
B

3NA7 250-6
3NA7 252-6

013
013

B
B

3NA6 250-6
3NA6 252-6

1 3 units
1 3 units

013
013

0.661
0.627

30

2 690/
4 250
6

80
100
1

30

57.8

50 690/
63 440
80

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/39

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links
Non-insulated
grip lugs
Sizes

Mounting
width

In

Un

mm

V AC/V DC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with front indicator,


operational class gG

000

00

}
}
}

3NA3 802-6
3NA3 804-6
3NA3 801-6

1 3 units
1 3 units
1 3 units

013
013
013

0.127
0.128
0.123

10
16
20

}
}
}

3NA3 803-6
3NA3 805-6
3NA3 807-6

1 3 units
1 3 units
1 3 units

013
013
013

0.123
0.126
0.133

25
32
35

}
B
}

3NA3 810-6
3NA3 812-6
3NA3 814-6

1 3 units
1 3 units
1 3 units

013
013
013

0.126
0.121
0.128

B
}
}

3NA3 817-6
3NA3 820-6
3NA3 822-6

1 3 units
1 3 units
1 3 units

013
013
013

0.190
0.191
0.191

}
}

3NA3 824-6
3NA3 830-6

1 3 units
1 3 units

013
013

0.195
0.200

B
B
B

3NA3 120-6
3NA3 122-6
3NA3 124-6

1 3 units
1 3 units
1 3 units

013
013
013

0.285
0.276
0.277

100
125
160

}
}
}

3NA3 130-6
3NA3 132-6
3NA3 136-6

1 3 units
1 3 units
1 3 units

013
013
013

0.274
0.288
0.286

47.2

200

3NA3 140-6

1 3 units

013

0.439

47.2

80
100
125

B
B
B

3NA3 224-6
3NA3 230-6
3NA3 232-6

1 3 units
1 3 units
1 3 units

013
013
013

0.455
0.448
0.452

160
200

}
}

3NA3 236-6
3NA3 240-6

1 3 units
1 3 units

013
013

0.424
0.451

224
250

B
}

3NA3 242-6
3NA3 244-6

1 3 units
1 3 units

013
013

0.657
0.652

300
315

B
}

3NA3 250-6
3NA3 252-6

1 3 units
1 3 units

013
013

0.631
0.666

B
B

3NA3 344-6
3NA3 352-6

1 3 units
1 3 units

013
013

0.659
0.634

21

30

2
4
6

40
50
63

690/250

690/250

80
100

30

57.8

50
63
80

690/440

690/440

57.8

250
315

690/440

71.2

355
400

B
}

3NA3 354-6
3NA3 360-6

1 3 units
1 3 units

013
013

0.982
1.026

425
500

B
}

3NA3 362-6
3NA3 365-6

1 3 units
1 3 units

013
013

1.025
0.982

* You can order this quantity or a multiple thereof.

5/40

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC fuse links
Non-insulated
grip lugs
Sizes

Mounting
width

In

Un

mm

V AC/V DC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LV HRC fuse links with front indicator,


operational class aM
000

21

6
10
16

500/--

B
B
B

3ND1 801
3ND1 803
3ND1 805

1 3 units
1 3 units
1 3 units

014
014
014

0.114
0.127
0.129

20
25
32

B
B
B

3ND1 807
3ND1 810
3ND1 812

1 3 units
1 3 units
1 3 units

014
014
014

0.128
0.122
0.130

35
40
50

B
B
B

3ND1 814
3ND1 817
3ND1 820

1 3 units
1 3 units
1 3 units

014
014
014

0.123
0.123
0.134

63
80

B
B

3ND1 822
3ND1 824

1 3 units
1 3 units

014
014

0.122
0.129

00

30

100
125
160

500/--

B
B
B

3ND1 830
3ND1 832
3ND1 836

1 3 units
1 3 units
1 3 units

014
014
014

0.177
0.189
0.199

30

63
80
100

690/--

B
B
B

3ND2 122
3ND2 124
3ND2 130

1 3 units
1 3 units
1 3 units

014
014
014

0.284
0.281
0.276

47.2

125
160

B
B

3ND2 132
3ND2 136

1 3 units
1 3 units

014
014

0.405
0.440

200
250

B
B

3ND2 140
3ND2 144

1 3 units
1 3 units

014
014

0.441
0.420

B
B

3ND2 232
3ND2 236

1 3 units
1 3 units

014
014

0.428
0.435

200
250

B
B

3ND2 240
3ND2 244

1 3 units
1 3 units

014
014

0.453
0.450

57.8

315
355
400

B
B
A

3ND2 252
3ND2 254
3ND2 260

1 3 units
1 3 units
1 3 units

014
014
014

0.634
0.654
0.629

57.8

315
355
400

B
B
B

3ND2 352
3ND2 354
3ND2 360

1 3 units
1 3 units
1 3 units

014
014
014

0.638
0.664
0.633

71.2

500
630

B
B

3ND1 365
3ND1 372

1 3 units
1 3 units

014
014

0.980
0.980

47.2

125
160

690/--

690/--

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/41

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC signal detectors

Overview
3NX1 024 signal detector top
The signal detector top can be used with LV HRC fuse links,
sizes 000, 00, 1 and 2, which are equipped with non-insulated
grip lugs and have a front indicator or combination alarm. It is
simply plugged into the grip lugs
5TT3 170 fuse monitors
If a fuse is tripped, the front indicator springs open and
switches a floating microswitch. This solution should not be
used for safety-relevant plants. For this purpose, we recommend our electronic fuse monitors.

Benefits
Uniform solution for all sizes
LV HRC signal detectors reliably indicate when a fuse has
tripped. Tripped fuses are quickly located. This saves time and
increases plant availability.

$
%
&
(
)
*

LV HRC fuse links


LV HRC signal detectors

Microswitch

The LV HRC signal detector top is a cost-effective solution for the


monitoring of Siemens LV HRC fuse links of sizes 000, 00, 1 and
2.

$
%
&
(

I2_13744

LV HRC signal detectors are used for remotely indicating that the
LV HRC fuse links have been tripped. 3 different solutions are
available:
3NX1 021 signal detectors with signal detector link
The LV HRC signal detectors with signal detector link support
monitoring of LV HRC fuse links with non-insulated grip lugs of
sizes 000 to 4 at 10 A or more. The signal detector link is connected in parallel to the LV HRC fuse link. In the event of a
fault, the LV HRC fuse links are released simultaneously with
the LV HRC fuse signaling link. A tripping pin switches a floating microswitch

Spring contact

LV HRC fuse links


Front indicator
Signal detector tops
Rocker/lever arm

Hinged lid

Signal detector links

5
4

$
(

2
3

&

5/42

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC signal detectors

Selection and ordering data


Sizes

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

3NX1 021

1 unit

014

0.039

kg
LV HRC signal detectors
000 ... 4
Only for SIEMENS 3NA3, 3NA7 and 3ND
LV HRC fuse links with non-insulated grip
lugs
Rated voltage up to 690 V AC/600 V DC
Contact: microswitches 250 V AC, 6 A
Connection: flat termination 2.3 mm

Signal detector links


000 ... 4
Rated voltage up to 690 V AC/600 V DC
Response value > 9 V; 2.5 A;
for standard applications

3NX1 022

1 3 units

014

0.014

Response value > 2 V; 7 A;


only for meshed networks

3NX1 023

1 3 units

014

0.023

000, 00, 1, 2 }

3NX1 024

1 unit

014

0.021

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Signal detector tops

Only for SIEMENS 3NA3, 3NA7 and 3ND


LV HRC fuse links with non-insulated grip
lugs
Rated voltage up to 690 V AC/600 V DC
Contact: microswitch 230 V AC, 5 A, 1 CO
Connection: flat termination 2.3 mm

Ue

In

Uc

Mount- DT
ing
width

V AC

MW

Order No.

kg

Fuse monitors
For all low-voltage fuse systems.
Can be used in asymmetric systems afflicted with
harmonics and regenerative feedback motors.
Signal also for disconnected loads.
230

3 AC 380 ... 415

5TT3 170

1 unit

027

0.153

For more information on fuse monitors, please refer to the chapter "Monitoring Devices > Monitoring of electrical values".

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/43

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC sockets and accessories

Overview
Terminals for all applications
Terminals are as different as the requirements of individual systems.

Flat terminals with screws are suitable for connecting busbars or


cable lugs. They have a torsion-proof screw connection with
shim, spring washer and nut. When tightening the nut, always
ensure compliance with the specified torque due to the considerable leverage effect.
The double busbar terminal differs from the flat connection in
that it supports connection of two busbars, one on the top and
one at the bottom of the flat connection.

The modern box terminal ensures efficient and reliable connection to the conductors. They support connection of conductors
with or without end sleeves.

With the flat connection with nut, terminal lug of the nut is torsionproof. When tightening the nut, the torque must be observed
because of the considerable leverage effect.

Up to three conductors can be clamped to the terminal strip.

The plug-in terminal is equipped for connecting two conductors.

One conductor can be clamped to the saddle-type terminal.

5/44

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC sockets and accessories

Benefits
The silver-plated Lyra contact provides a large contact area
for the pin of the LV HRC fuse link. This improves heat transmission and lowers the temperature. It also minimizes the aging of the fuse link in the maximum load range, in particular
when using SITOR fuses
The large contact area also facilitates replacement of
LV HRC fuse links
The spring washer tensioning the contact is mechanically
galvanized. This will prevent hydrogen embrittlement. The
contact is resistant to aging and there will be no dreaded annealing of contacts, which considerably improves operating
safety.

Technical specifications
LV HRC fuse bases, LV HRC bus-mounting bases
Size

000/00

Standards

IEC 60269-1, -2; EN 60269-1; DIN VDE 0636-2

Rated current In

160

160

Rated voltage Un

V AC
V DC

6901)
250

6901)
440

Rated short-circuit strength

kA AC

120

kA DC

25

Nm

M8
M8
14

mm2

2.5 ... 50

mm2

6 ... 70

mm2

2.5 ... 50

mm2
Nm

1.5 ... 16
2

1
250

400

630

1250
690
440

Flat terminal
Screw
Nut
Max. tightening torque

M10

M12

-38

65

Plug-in terminal
Conductor cross-section

--

Saddle-type terminal
Conductor cross-section

--

Box terminals
Conductor cross-section
Terminal strips
Conductor cross-section, 3-wire
Max. torque
for attachment of LV HRC fuse base
1)

-2.5

--

Extended rated voltage up to 1000 V (except LV HRC bus-mounting bases).


LV HRC fuse bases with swivel mechanism

Size

000/00

4a

20

32

M8
M8
14

M10
-38

M12

M16

Rated voltage Un

V AC
V DC

690
440

Power loss

Nm

Flat terminal
Screw
Nut
Max. tightening torque

65

Siemens LV 10.1 2011

5/45

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC sockets and accessories

Selection and ordering data


Sizes

In

Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

A
LV HRC fuse bases
Made of molded plastic, for standard rail mounting or screw fixing

160

1P
With flat terminals, screw
With saddle-type terminals

}
}

3NH3 051
3NH3 052

1 1/10 units
1 1/10 units

014
014

0.149
0.010

125

With box terminal, up to 50 mm2

3NH3 053

1 1/10 units

014

0.118

1P
With flat terminals, screw
With plug-in terminals
With saddle-type terminals

}
B
}

3NH3 030
3NH3 031
3NH3 032

1
1
1

3 units
3 units
3 units

014
014
014

0.217
0.260
0.204

With flat terminals and terminal strip


With flat terminals, nut
With flat and saddle-type terminals

B
B
B

3NH3 035
3NH3 038
3NH3 050

1
1
1

3 units
3 units
3 units

014
014
014

0.229
0.177
0.217

3P (incl. two partitions)


With flat terminals
With plug-in terminals
With saddle-type terminals
With flat terminals and terminal strip

}
B
B
B

3NH4 030
3NH4 031
3NH4 032
3NH4 035

1
1
1
1

1 unit
1 unit
1 unit
1 unit

014
014
014
014

0.715
0.883
0.717
0.743

A
B

3NH3 120
3NH3 122

1
1

3 units
3 units

014
014

0.411
0.473

}
B

3NH3 230
3NH3 220

1
1

3 units
3 units

014
014

0.738
0.737

3NH4 230

1 unit

014

2.086

}
A

3NH3 330
3NH3 320

1
1

1 unit
1 unit

014
014

0.817
0.819

}
A

3NH3 430
3NH3 420

1
1

1 unit
1 unit

014
014

1.077
1.080

000/00

Made of ceramic for screw fixing


000/00

160

Made of ceramic for screw fixing


0

160

1P
With flat terminals
With plug-in terminals

Made of ceramic for screw fixing


1

250

1P
With flat terminals
With double busbar terminals

Ceramic supports on base plate for screw fixing


1

250

3P (incl. two partitions)


With flat terminals

Made of ceramic for screw fixing


2

400

1P
With flat terminals
With double busbar terminals

Made of ceramic for screw fixing


3

630

1P
With flat terminals
With double busbar terminals

* You can order this quantity or a multiple thereof.

5/46

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC sockets and accessories
Sizes

In

Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

A
LV HRC fuse bases
Ceramic supports on base plate for screw fixing
(IEC design)
4

1250 1P
With flat terminals

3NH3 530

1 unit

014

3.116

B
B

3NH3 036
3NH3 037

1
1

1 unit
1 unit

014
014

0.235
0.243

B
B

3NH4 037
3NH4 045

1
1

1 unit
1 unit

014
014

1.023
0.997

A
B

3NH7 030
3NH7 031

1
1

1 unit
1 unit

014
014

0.416
0.421

3NH7 032

1 unit

014

0.393

A
B

3NH7 230
3NH7 231

1
1

1 unit
1 unit

014
014

1.086
1.501

3NH7 232

1 unit

014

1.212

B
B

3NH7 330
3NH7 331

1
1

1 unit
1 unit

014
014

2.157
2.523

3NH7 332

1 unit

014

2.450

LV HRC bus-mounting base made of molded plastic


For busbars 12 mm 5 mm to 12 mm 10 mm,
busbar space 40 mm
000/00

000/00

160 1P
With top saddle-type terminal
With bottom saddle-type terminal

80 3P, in tandem design


3 outgoing feeders, top and bottom with
saddle-type terminal
With 4 barriers
With 2 non-interrupted barriers

LV HRC fuse bases with swivel mechanism


With flat terminals and additional
saddle-type terminals (included)
000/00

160 1P
With screw fixing for mounting plate
With claw fixing for non-perforated
busbar
With screw fixing for perforated
busbar

250 1P
With screw fixing for mounting plate
With claw fixing for non-perforated
busbar
With screw fixing for perforated
busbar

Can also be used for fuse links of size 2


3

630 1P
With screw fixing for mounting plate
With claw fixing for non-perforated
busbar
With screw fixing for perforated
busbar, can be used as disconnector

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/47

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC sockets and accessories
Sizes

In

Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

A
LV HRC fuse bases with swivel mechanism
4a

1250 1P
With screw fixing
for mounting plate

3NH7 520

1 unit

014

5.428

000/00
0
1

}
B
}

3NX3 105
3NX3 114
3NX3 106

1
1
1

2/20 units
2/40 units
2/20 units

014
014
014

0.009
0.010
0.010

2
3

}
}

3NX3 107
3NX3 108

1
1

2/12 units
2/10 units

014
014

0.024
0.030

LV HRC contact covers for LV HRC fuse bases


Touch protection for contact pieces

LV HRC partitions for LV HRC fuse bases


As intermediate phase and end barrier
000/00

Type

0
1

3NH3 0/3NH4 0
3NH3 1
3NH3 2

}
B
}

3NX2 023
3NX2 030
3NX2 024

1
1
1

2 units
2 units
2 units

014
014
014

0.027
0.033
0.048

2
3

3NH3 3
3NH3 4

}
}

3NX2 025
3NX2 026

1
1

2 units
2 units

014
014

0.063
0.076

3NX3 115

10 units

014

0.039

3NX3 116

10 units

014

0.014

}
B

3NX3 105
3NX3 113

1
1

2/20 units
2/50 units

014
014

0.009
0.006

LV HRC protective covers IP2X


For LV HRC fuse bases
1P and 3P

000/00

LV HRC covers
000/00

For plugging into IP2X LV HRC protective


covers

LV HRC contact covers for LV HRC bus-mounting


bases
000/00

Touch protection for contact pieces


Outgoing terminal
Incoming terminal

LV HRC partitions for 3NH3 0 LV HRC bus-mounting


bases
000/00

As phase barrier

3NX2 027

2 units

014

0.018

000/00

As end barrier

3NX2 028

2/50 units

014

0.040

* You can order this quantity or a multiple thereof.

5/48

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
LV HRC Fuse Systems
LV HRC sockets and accessories
Sizes

Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Non-interrupted barriers
000/00

For 3NH4 0 LV HRC bus-mounting bases

3NX2 031

1 2/30 units

014

0.067

Fuse-base covers
For LV HRC fuse bases, red,
with inscription "Trennstelle" (isolating point)
C
C

3NX1 003
3NX1 004

1
1

3 units
3 units

014
014

0.013
0.087

Without sleeve

3NX1 013

1 unit

014

0.301

With sleeve

3NX1 014

1 unit

014

0.558

}
C

3NG1 002
3NG1 102

1 3/30 units
1 1/10 units

014
014

0.066
0.116

}
}
}

3NG1 202
3NG1 302
3NG1 402

1 1/10 units
1
1/5 units
1
1/5 units

014
014
014

0.159
0.228
0.281

B
B

3NG1 503
3NG1 505

1
1

014
014

0.679
0.701

000/00
1, 2, 3

Fuse pullers
000 ... 4

For LV HRC fuse links

Isolating links
For LV HRC fuse bases and
fuse switch disconnectors
With insulated grip lugs
000/00
0

Silver-plated

1
2
3
With non-insulated grip lugs
4
4a

Tinned
Nickel-plated

3 units
1/5 units

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/49

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design

Overview

Benefits

SITOR fuses protect power semiconductors from the effects of


short circuits because the super quick disconnect characteristic
is far quicker than with conventional LV HRC fuses (NH type).
They protect expensive devices and system components, such
as converters with fuses in the input and the DC link, UPS systems and soft starters for motors.

Panel mounting requirements have given rise to various connection versions and designs.
The fuses with blade contacts comply with IEC 60269-2 and are
suitable for installation in LV HRC fuse bases, in LV HRC fuse
switch disconnectors and switch disconnectors with fuses. They
also include fuses with slotted blade contacts for screw fixing
with 110 mm mounting dimension, whose sizes are according to
IEC 60269-4.
Fuses with slotted blade contacts for screw fixing with 80 mm or
110 mm mounting dimension are often screwed directly onto
busbars for optimum heat dissipation. Even better heat transmission is provided by the compact fuses with M10 or M12 female
thread, which are also mounted directly onto busbars.
Bolt-on links with 80 mm mounting dimension are another panelmounting version for direct busbar mounting.
The fuses for SITOR thyristor sets, railway rectifiers or electrolysis systems were developed specially for these applications.
The LV HRC bases useable for SITOR fuses and safety switching
devices are on pages 5/46 and 5/47.
Fuse characteristics, configuration notes and the assignments
of SITOR fuses to the fuse bases and 3NP and 3KL safety
switching devices can be found under:
www.siemens.com/lowvoltage/manuals
The new size 3 type ranges have a round ceramic body instead
of a square one. These series are characterized by small It values with low power dissipation and high capability under alternating load. The dimensions and functional dimensions correspond to the current standards IEC 60269-4/ EN 60269-4.
Note:
The ordering data of the fuses are listed in ascending order of
the rated voltage in the selection tables.

5/50

Siemens LV 10.1 2011

SITOR fuses have a high varying load factor, which ensures a


high level of operating safety and plant availability - even
when subject to constant load change.
The use of SITOR fuses in LV HRC bases or Siemens switch
disconnectors has been tested with regard to heat dissipation
and maximum current loading. This makes planning and
dimensioning easier and prevents consequential damage.
Our high standard of quality ensures good compliance with
the characteristic curve and accuracy. This ensures long-term
protection of devices.

Operational classes
Fuses are categorized according to function and operational
classes. SITOR semiconductor fuses, in LV HRC design, are
available in the following operational classes:
aR: for the short-circuit protection of power semiconductors
(partial range protection)
gR: for the protection of power semiconductors
(full range protection)
gS: The operational class gS combines cable and line protection with semiconductor protection (full range protection).

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design

Selection and ordering data


Sizes

Ie

Ue

V AC

Opera- Breaking
I2t value
tional
classes
A2s

Power Varyloss
ing
load
factor
W

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

WL

Weight
per PU
approx.
kg

SITOR LV HRC design


With slotted blade contacts for M10 screw fixing, mounting
dimension: 110 mm, or for installation in LV HRC fuse
bases or switch disconnectors
3

150
200
250
300
350
400

500 gR

aR

33 000 35
64 000 40
99 000 50

0.85
0.85
0.85

B
B
B

3NC2 423-3C
3NC2 425-3C
3NC2 427-3C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

132 000 65
249 000 60
390 000 50

0.85
0.85
0.85

B
B
B

3NC2 428-3C
3NC2 431-3C
3NC2 432-3C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

With slotted blade contacts with two M10 oblong slots, or


for installation in LV HRC fuse bases or fuse switch disconnectors
3

150
200
250
300
350
400

500 gR

aR

33 000 35
64 000 40
99 000 50

0.85
0.85
0.85

D
D
D

3NC2 423-0C
3NC2 425-0C
3NC2 427-0C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

132 000 65
249 000 60
390 000 50

0.85
0.85
0.85

D
C
D

3NC2 428-0C
3NC2 431-0C
3NC2 432-0C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

D
B

3NE1 437-1
3NE1 438-1

1 3 units
1 3 units

047
047

1.179
1.100

0.85
0.85
0.85

B
B
B

3NC8 423-3C
3NC8 425-3C
3NC8 427-3C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

0.85
0.85
0.9

B
B
C

3NC8 431-3C
3NC8 434-3C
3NC8 444-3C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

D
D
D
D

3NE1 224-3
3NE1 225-3
3NE1 227-3
3NE1 230-3

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.610
0.610
0.610
0.610

D
D
D
D

3NE1 331-3
3NE1 332-3
3NE1 333-3
3NE1 334-3

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.750
0.750
0.750
0.750

With blade contacts for mounting in LV HRC fuse bases or


switch disconnectors
3

710
800

600 gR

2 460 000 65
3 350 000 72

1.0
1.0

With slotted blade contacts for M10 screw fixing, mounting


dimension: 110 mm, or for installation in LV HRC fuse
bases or switch disconnectors
3

150
200
250
350
500
1 000

690 gR

600 aR

17 600 40
38 400 55
70 400 72
176 000 95
448 000 130
2 480 000 140

With slotted blade contacts for M10 screw fixing, mounting


dimension: 110 mm, or for installation in LV HRC fuse
bases or switch disconnectors
1

160
200
250
315

690 gR

18 600
51 800
80 900
168 000

30
28
35
42

1.0
1.0
1.0
1.0

With slotted blade contacts for M10 screw fixing, mounting


dimension: 110 mm, or for installation in LV HRC fuse
bases or switch disconnectors
2

350
400
450
500

690 gR

177 000
224 000
276 500
398 000

44
54
62
65

1.0
1.0
1.0
1.0

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/51

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design
Sizes

Ie

Ue

V AC

Operational
classes

Breaking
I2t value

Power
loss

Varying
load
factor

A2s

WL

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With slotted blade contacts for M12 screw fixing, mounting
dimension: 110 mm, or for installation in LV HRC fuse bases
or switch disconnectors

560
630
670

690 gR

710
800
850

890 000 60
1 390 000 62
1 640 000 65

1.0
1.0
1.0

D
D
D

3NE1 435-3
3NE1 436-3
3NE1 447-3

1 3 units
1 3 units
1 3 units

047
047
047

1.150
1.150
1.150

1 818 000 72
2 475 000 82
3 640 000 76

1.0
1.0
1.0

D
D
D

3NE1 437-3
3NE1 438-3
3NE1 448-3

1 3 units
1 3 units
1 3 units

047
047
047

1.150
1.150
1.150

With slotted blade contacts with two M10 oblong slots for
screw fixing, or for installation in LV HRC fuse bases or switch
disconnectors
3

150
200
250

690 gR

350
500

Size

Ie

Ue

V AC/
V DC

Operational
classes

17 600 40
38 400 55
70 400 72

0.85
0.85
0.85

B
B
B

3NC8 423-0C
3NC8 425-0C
3NC8 427-0C

1 3 units
1 3 units
1 3 units

047
047
047

0.940
0.940
0.940

176 000 95
448 000 130

0.85
0.85

B
B

3NC8 431-0C
3NC8 434-0C

1 3 units
1 3 units

047
047

0.940
0.940

Breaking Power
I2t value loss

Varying
load
factor

DT

Order No.

A2s

WL

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With M8 bolt-on links, mounting dimension: 80 mm,
for screwing onto busbars
000

1)

20

690/ gR
7001)

83 7

0.9

3NE8 714-1

1 10 units

047

0.128

25
32

140 9
285 10

0.9
0.9

B
A

3NE8 715-1
3NE8 701-1

1 10 units
1 10 units

047
047

0.130
0.110

40
50
63

490 12
815 15
1 550 16

0.9
0.9
0.95

A
A
A

3NE8 702-1
3NE8 717-1
3NE8 718-1

1 10 units
1 10 units
1 10 units

047
047
047

0.122
0.131
0.130

80
100
125

2 700 18
4 950 19
9 100 23

0.9
0.95
0.95

}
}
}

3NE8 720-1
3NE8 721-1
3NE8 722-1

1 10 units
1 10 units
1 10 units

047
047
047

0.132
0.123
0.130

160
200
250

17 000 31
30 000 36
55 000 42

0.9
0.9
0.9

}
}
}

3NE8 724-1
3NE8 725-1
3NE8 727-1

1 10 units
1 10 units
1 10 units

047
047
047

0.122
0.117
0.132

315

85 500 54

0.85

3NE8 731-1

1 10 units

047

0.127

aR

DC voltage acc. to UL.

* You can order this quantity or a multiple thereof.

5/52

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design
Sizes

Ie

Ue

V AC

Operational
classes

Breaking
I2t value

Power
loss

Varying
load
factor

A 2s

WL

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With blade contacts for mounting in LV HRC fuse bases or
switch disconnectors
000

200 3.0
430 3.5
780 4.0

1.0
1.0
1.0

}
}
}

3NE1 813-0
3NE1 814-0
3NE1 815-0

1 3 units
1 3 units
1 3 units

047
047
047

0.133
0.124
0.127

35
40
50

1 700 5.0
3 000 5.0
4 400 6.0

1.0
1.0
1.0

}
}
}

3NE1 803-0
3NE1 802-0
3NE1 817-0

1 3 units
1 3 units
1 3 units

047
047
047

0.128
0.126
0.129

63
80

9 000 7.0
18 000 8.0

1.0
1.0

}
}

3NE1 818-0
3NE1 820-0

1 3 units
1 3 units

047
047

0.126
0.124

33 000 10
63 000 11

1.0
1.0

}
}

3NE1 021-0
3NE1 022-0

1 3 units
1 3 units

047
047

0.204
0.195

16
20
25

690 gS

00

100
125

690 gS

160
200
250
315

690 gS

60 000
100 000
200 000
310 000

24
27
30
38

1.0
1.0
1.0
1.0

}
}
}
A

3NE1 224-0
3NE1 225-0
3NE1 227-0
3NE1 230-0

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.522
0.518
0.515
0.519

350
400
450
500

690 gS

430 000
590 000
750 000
950 000

42
45
53
56

1.0
1.0
1.0
1.0

}
}
A
A

3NE1 331-0
3NE1 332-0
3NE1 333-0
3NE1 334-0

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.687
0.519
0.689
0.765

560
630
710
800

690 gS

1 700 000
2 350 000
3 400 000
5 000 000

50
55
60
59

1.0
1.0
1.0
1.0

A
A
A
A

3NE1 435-0
3NE1 436-0
3NE1 437-0
3NE1 438-0

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

1.000
1.113
1.045
1.560

00

80
100
125

690 gR

1.0
1.0
1.0

A
A
A

3NE1 020-2
3NE1 021-2
3NE1 022-2

1 3 units
1 3 units
1 3 units

047
047
047

0.200
0.197
0.195

160
200
250
315

690 gR

18 600
51 800
80 900
168 000

30
28
35
42

1.0
1.0
1.0
1.0

A
A
A
A

3NE1 224-2
3NE1 225-2
3NE1 227-2
3NE1 230-2

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.535
0.508
0.533
0.519

350
400
450
500

690 gR

177 000
224 000
276 500
398 000

44
54
62
65

1.0
1.0
1.0
1.0

A
D
A
A

3NE1 331-2
3NE1 332-2
3NE1 333-2
3NE1 334-2

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.684
0.760
0.691
0.695

560
630
670

690 gR

890 000 60
1 390 000 62
1 640 000 65

1.0
1.0
1.0

A
A
A

3NE1 435-2
3NE1 436-2
3NE1 447-2

1 3 units
1 3 units
1 3 units

047
047
047

1.098
1.038
1.044

1 818 000 72
2 475 000 82
3 640 000 76

1.0
1.0
1.0

B
A
A

3NE1 437-2
3NE1 438-2
3NE1 448-2

1 3 units
1 3 units
1 3 units

047
047
047

1.031
1.067
1.048

710
800
850

5 800 10.5
11 000 11.5
23 000 13.5

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/53

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design
Sizes

Ie

Ue

V AC

Operational
classes

Breaking
I2t value

Power
loss

Varying
load
factor

A2s

WL

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With blade contacts for mounting in LV HRC fuse bases or
switch disconnectors (contd.)
00

25
35
50

690 gR

63
80
100

aR

125
160

180 7
400 9
700 14

0.95
0.95
0.95

}
}
}

3NE8 015-1
3NE8 003-1
3NE8 017-1

1 3 units
1 3 units
1 3 units

047
047
047

0.193
0.195
0.614

1 400 16
2 400 19
4 200 22

0.95
0.95
0.95

}
}
}

3NE8 018-1
3NE8 020-1
3NE8 021-1

1 3 units
1 3 units
1 3 units

047
047
047

0.196
0.206
0.207

6 500 28
13 000 38

0.95
0.95

}
}

3NE8 022-1
3NE8 024-1

1 3 units
1 3 units

047
047

0.195
0.195

120
130
135
145

0.85
0.85
0.9
0.9

C
D
C
D

3NC3 236-1
3NC3 237-1
3NC3 238-1
3NC3 240-1

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.785
0.785
0.785
0.785

975 000 155


1 382 000 165
1 990 000 175

0.95
0.95
0.95

C
D
C

3NC3 241-1
3NC3 242-1
3NC3 243-1

1 3 units
1 3 units
1 3 units

047
047
047

0.785
0.785
0.785

2 100 000 200


2 860 000 240

0.95
0.9

D
D

3NC3 244-1
3NC3 245-1

1 3 units
1 3 units

047
047

0.785
0.785

0.9
0.9
0.95
0.95

C
D
C
D

3NC3 236-6
3NC3 237-6
3NC3 238-6
3NC3 240-6

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.765
0.765
0.765
0.765

975 000 145


1 382 000 150
1 990 000 155

1.0
1.0
1.0

C
D
C

3NC3 241-6
3NC3 242-6
3NC3 243-6

1 3 units
1 3 units
1 3 units

047
047
047

0.765
0.765
0.765

2 100 000 175


2 860 000 195

1.0
0.95

C
C

3NC3 244-6
3NC3 245-6

1 3 units
1 3 units

047
047

0.765
0.765

With slotted blade contacts for M12 screw fixing,


mounting dimension: 80 mm
3

630
710
800
900

690 aR

1 000
1 100
1 250
1 400
1 600

500

244 000
346 000
498 000
677 000

With M12 female thread at both ends for direct busbar


mounting
3

630
710
800
900

690 aR

1 000
1 100
1 250
1 400
1 600

500

244 000
346 000
498 000
677 000

125
130
135
140

With slotted blade contacts for M10 screw fixing, mounting


dimension: 110 mm, or for installation in LV HRC fuse bases
or switch disconnectors
2

250
315
450

800 aR

500
710

29 700 105
60 700 120
191 000 140

0.85
0.85
0.85

}
}
}

3NE4 327-0B
3NE4 330-0B
3NE4 333-0B

1 3 units
1 3 units
1 3 units

047
047
047

0.780
1.539
0.682

276 000 155


923 000 155

0.85
0.85

}
}

3NE4 334-0B
3NE4 337

1 3 units
1 3 units

047
047

0.683
0.689

With blade contacts for mounting in LV HRC fuse bases or


switch disconnectors
0

32 1 000 gR
40
50
63
80
100
125
160

aR

280 12
500 13
800 16

0.9
0.9
0.9

}
}
}

3NE4 101
3NE4 102
3NE4 117

1 3 units
1 3 units
1 3 units

047
047
047

0.824
0.258
0.274

1 500 20
3 000 22
6 000 24

0.9
0.9
0.9

}
}
}

3NE4 118
3NE4 120
3NE4 121

1 3 units
1 3 units
1 3 units

047
047
047

0.257
0.261
0.260

14 000 30
29 000 35

0.9
0.9

}
}

3NE4 122
3NE4 124

1 3 units
1 3 units

047
047

0.265
0.274

* You can order this quantity or a multiple thereof.

5/54

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design
Sizes

Ie

Ue

V AC

Operational
classes

Breaking
I2t value

Power
loss

Varying
load
factor

A2s

WL

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With slotted blade contacts for M10 screw fixing, mounting
dimension: 110 mm, or for installation in LV HRC fuse bases
or switch disconnectors
1

100 1 000 aR
125
160

4 800 28
7 200 36
13 000 42

0.95
0.95
0.95

A
A
}

3NE3 221
3NE3 222
3NE3 224

1 3 units
1 3 units
1 3 units

047
047
047

0.510
0.506
0.513

200
250
315

30 000 42
48 000 50
80 000 65

0.95
0.95
0.95

}
}
}

3NE3 225
3NE3 227
3NE3 230-0B

1 3 units
1 3 units
1 3 units

047
047
047

0.586
0.580
0.513

350
400
450

100 000 75
135 000 85
175 000 95

0.9
0.9
0.9

A
A
}

3NE3 231
3NE3 232-0B
3NE3 233

1 3 units
1 3 units
1 3 units

047
047
047

0.515
0.520
0.580

400 1 000 aR
450
500

135 000 85
175 000 90
260 000 90

1.0
1.0
1.0

A
A
}

3NE3 332-0B
3NE3 333
3NE3 334-0B

1 3 units
1 3 units
1 3 units

047
047
047

0.683
0.687
0.697

560
630

360 000 95
600 000 100

1.0
1.0

}
}

3NE3 335
3NE3 336

1 3 units
1 3 units

047
047

0.692
0.810

800 000 105


850 000 130
920 000 165

1.0
0.95
0.95

}
}
}

3NE3 337-8
3NE3 338-8
3NE3 340-8

1 3 units
1 3 units
1 3 units

047
047
047

0.687
0.686
0.657

710
800
900

900 aR
800
690

With slotted blade contacts for M10 screw fixing, mounting


dimension: 130 mm
3

100 1 000 aR
224
315

13 500 25
54 000 85
218 000 80

1.0
1.0
1.0

D
B
B

3NE3 421-0C
3NE3 626-0C
3NE3 430-0C

1 3 units
1 3 units
1 3 units

047
047
047

1.120
1.120
1.120

400
450

364 000 110


488 000 110

1.0
1.0

B
B

3NE3 432-0C
3NE3 635-0C

1 3 units
1 3 units

047
047

1.120
1.120

500
630
710

870 000 95
1 280 000 132
1 950 000 145

1.0
1.0
1.0

B
D
D

3NE3 434-0C
3NE3 636-0C
3NE3 637-0C

1 3 units
1 3 units
1 3 units

047
047
047

1.120
1.120
1.120

3NE3 635-6

1 3 units

047

1.184

3NE3 637-1C

1 3 units

047

1.120

0.85
0.85
0.85
0.9
0.9

C
D
C
D
C

3NC3 336-1
3NC3 337-1
3NC3 338-1
3NC3 340-1
3NC3 341-1

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

1.020
1.020
1.020
1.020
1.020

0.9
0.9

D
D

3NC3 342-1
3NC3 343-1

1 3 units
1 3 units

047
047

1.020
1.020

With M10 female thread at both ends for direct mounting on


busbars
3

450 1 000 aR

488 000 110

1.0

With slotted blade contacts for M12 screw fixing, mounting


dimension: 140 mm
3

710 1 000 aR

1 950 000 145

1.0

With slotted blade contacts for M12 screw fixing, mounting


dimension: 110 mm, or for installation in LV HRC fuse bases
or switch disconnectors
3

630 1 000 aR
710
800
900
1 000

418 000
569 000
819 000
1 160 000
1 670 000

1 100
1 250

1 910 000 185


2 600 000 210

800

145
150
155
165
170

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/55

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design
Sizes

Ie

Ue

V AC

Operational
classes

Breaking
I2t value

Power
loss

Varying
load
factor

A2s

WL

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With M12 female thread at both ends for direct busbar
mounting
3

630 1 000 aR
710
800
900
1 000

418 000
569 000
819 000
1 160 000
1 670 000

130
140
150
160
165

0.90
0.90
0.90
0.95
0.95

C
D
C
D
C

3NC3 336-6
3NC3 337-6
3NC3 338-6
3NC3 340-6
3NC3 341-6

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

0.980
0.980
0.980
0.980
0.980

1 100
1 250

1 910 000 175


2 600 000 185

0.95
0.95

D
C

3NC3 342-6
3NC3 343-6

1 3 units
1 3 units

047
047

0.980
0.980

800

With slotted blade contacts for M12 screw fixing,


mounting dimension: 110 mm
3

315 1 250 aR
400
500
630

72 500
163 000
290 000
650 000

80
95
115
120

0.95
0.95
0.90
0.95

D
D
D
D

3NC3 430-1
3NC3 432-1
3NC3 434-1
3NC3 436-1

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

1.010
1.010
1.010
1.010

800 1 100

985 000 145

0.90

3NC3 438-1

1 3 units

047

1.150

With M12 female thread at both ends for direct busbar


mounting
3

315 1 250 aR
400
500
630

72 500
163 000
290 000
650 000

80
95
115
120

0.95
0.95
0.90
0.95

D
D
D
D

3NC3 430-6
3NC3 432-6
3NC3 434-6
3NC3 436-6

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

1.010
1.010
1.010
1.010

800 1 100

985 000 145

0.95

3NC3 438-6

1 3 units

047

1.110

With slotted blade contacts for M10 screw fixing, mounting


dimension: 210 mm
3

160 1 500 aR
224
315

54 000 56
138 000 80
311 000 115

1.0
1.0
1.0

D
C
D

3NE5 424-0C
3NE5 426-0C
3NE5 430-0C

1 2 units
1 2 units
1 2 units

047
047
047

1.860
1.860
1.860

350
450

428 000 135


870 000 145

1.0
0.95

D
D

3NE5 431-0C
3NE5 433-0C

1 2 units
1 2 units

047
047

1.860
1.860

3NE5 433-1C

1 2 units

047

1.860

D
B
D

3NE5 627-0C
3NE5 633-0C
3NE5 643-0C

1 3 units
1 3 units
1 3 units

047
047
047

1.520
1.520
1.520

With slotted blade contacts for M12 screw fixing, mounting


dimension: 210 mm
450

870 000 145

0.95

With slotted blade contacts for M10 screw fixing, mounting


dimension: 170 mm
3

250 1 500 aR
450
600

84 000 130
590 000 160
1 950 000 145

1.0
1.0
1.0

With slotted blade contacts for M10 screw fixing, mounting


dimension: 210 mm
3

200 2 000 aR
250
350
400
450
630

138 000
218 000
555 000
870 000

75
110
120
150

1.0
1.0
1.0
1.0

D
D
D
D

3NE7 425-0C
3NE7 427-0C
3NE7 431-0C
3NE7 432-0C

1
1
1
1

2 units
2 units
2 units
2 units

047
047
047
047

1.860
1.860
1.860
1.860

960 000 160


1 950 000 220

1.0
1.0

D
D

3NE7 633-0C
3NE7 636-0C

1 2 units
1 2 units

047
047

1.860
1.860

C
D
C
B

3NE7 633-1C
3NE7 648-1C
3NE7 636-1C
3NE7 637-1C

1 2 units
1 2 units
1 1 unit
1 2 units

047
047
047
047

1.860
1.860
1.860
1.860

With slotted blade contacts for M12 screw fixing, mounting


dimension: 210 mm
3

450 2 000 aR
525
630
710

960 000
1 120 000
1 950 000
3 110 000

160
210
220
275

1.0
1.0
1.0
1.0

* You can order this quantity or a multiple thereof.

5/56

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR LV HRC design
Sizes

Ie

Ue

V AC

Operational
classes

Breaking
I2t value

Power
loss

Varying
load
factor

A2s

WL

DT

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

SITOR LV HRC design


With slotted blade contacts for M12 screw fixing, mounting
dimension: 260 mm
3

125 2 500 aR
400
500
630

34 500 78
620 000 250
1 270 000 235
2 800 000 275

1.0
1.0
1.0
1.0

D
D
D
D

3NE9 622-1C
3NE9 632-1C
3NE9 634-1C
3NE9 636-1C

1
1
1
1

1 unit
1 unit
1 unit
1 unit

047
047
047
047

2.500
2.350
2.350
2.350

Fuses for special applications


For screwing onto water-cooled busbars, for rectifiers in
electrolysis systems
--1)

350
800 aR
600 1 000
630
800
800 1 000
710
1 250

900
600

260 000
888 000
888 000
1 728 000

80
150
145
170

0.9
0.9
0.9
0.9

X
D
D
D

3NC5 531
3NC5 840
3NC5 841
3NC5 838

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.671
1.485
1.177
3.569

620 000 150


2 480 000 210

0.9
0.9

D
D

3NE6 437-7
3NE9 450-7

1 3 units
1 3 units

047
047

1.062
1.072

D
D
C
D

3NE6 437
3NE9 440-6
3NE6 444
3NE9 450

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

1.030
0.960
1.105
1.011

D
D

3NE3 525-5
3NE3 535-5

1 2 units
1 2 units

047
047

0.744
0.735

C
B
B

3NE4 117-5
3NE4 121-5
3NE4 146-5

1 2 units
1 2 units
1 2 units

047
047
047

0.300
0.299
0.287

With M10 female thread at both ends for direct busbar


mounting, for air-cooled rectifiers in electrolysis systems
--1)

710
850
900
1 250

900
600
900
600

aR
gR
aR
aR

620 000
2 480 000
1 920 000
2 480 000

150
85
170
210

0.9
1.0
0.9
0.9

Fuses with installation holder for SITOR 6QG10 thyristor sets


--

200 1 000 aR
450

44 000 50
395 000 90

0.85
0.85

Fuses with installation holder for SITOR 6QG11 thyristor sets


--1)

50 1 000 gR
100
aR
170
aR

1 100 20
7 400 35
60 500 43

0.85
0.85
0.85

Fuses female thread at both ends for SITOR 6QG12 thyristor


sets
--1)

250
315
450

800 aR

500
710

29 700 105
60 700 120
191 000 140

0.85
0.85
0.85

}
}
}

3NE4 327-6B
3NE4 330-6B
3NE4 333-6B

1 3 units
1 3 units
1 3 units

047
047
047

0.650
0.655
0.642

276 000 155


923 000 155

0.85
0.95

}
}

3NE4 334-6B
3NE4 337-6

1 3 units
1 3 units

047
047

0.681
0.640

D
D

3NC7 327-2
3NC7 331-2

1 3 units
1 3 units

047
047

0.670
0.740

With M12 female thread at both ends for direct mounting on


busbars for railway supply rectifiers
--1)

1)

250
350

680 aR

635 000 25
1 430 000 32

0.9
0.9

Special design

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/57

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR, cylindrical fuse design

Overview

Benefits

SITOR cylindrical fuses protect power semiconductors from the


effects of short-circuits because the super quick disconnect
characteristic is far quicker than that of conventional fuses. They
protect expensive devices and system components such as
solid-state contactors, electronic relays (solid state), converters
with fuses in the input and in the DC link, UPS systems and soft
starters for motors up to 100 A.

The cylindrical design is approved for industrial applications.


The cylindrical fuse links comply with IEC 60269.
Cylindrical fuse holders also comply with IEC 60269 and
UL 512. The cylindrical fuse holders for 10 x 38 mm and
14 x 51 mm have been tested and approved as fuse switch disconnectors and the cylindrical fuse holders for 22 x 58 mm as
fuse disconnectors according to the switching device standard
IEC 60947-3. The utilization category and the tested current and
voltage values are specified in the Table "Technical Specifications".

Cylindrical fuses have an extremely compact design and a


correspondingly small footprint
The cylindrical fuses have IEC and UL approval and are suitable for universal use worldwide.
The use of SITOR cylindrical fuses in the cylindrical fuse holders and bases has been tested with regard to heat dissipation
and maximum current loading. This makes planning and
dimensioning easier and prevents consequential damage.
The use of fuse holders as switch disconnectors expands the
area of application of these devices and increases operating
safety.

The cylindrical fuse holders have been specially developed for


the application of SITOR fuse links with regard to heat tolerance
and heat dissipation and are therefore not recommended for
standard applications.
Cylindrical fuse bases do not offer the same comprehensive
touch protection as the fuse holders, but have better heat dissipation. The single-pole cylindrical fuse bases for 14 x 51 mm
and 22 x 58 mm allow modular expansion to multipole bases.

Technical specifications
mm mm

Sizes

10 38

14 51

22 58

Cylindrical fuse links


3NC1 0, 3NC1 4, 3NC2 2
IEC 60269-4; UL 248-13; CSA C22.2 No. 248.13
UL 248-13; UL File No. E167357; CSA C22.2 No. 248.13

Standards
Approvals

Fuse holders, fuse bases


3NC1, 3NC2
IEC 60269-2; EN 60947-3; UL 512; CSA C22.2 No. 39-M
UL 512; UL File No. E220063; CSA C22.2 No. 39-M

Standards
Approvals
Rated voltage

V AC

690

Rated current In

32

50

100

Max. power dissipation of fuse links


(conductor cross-section used)

3 (6 mm2)
4.3 (10 mm2)

5 (10 mm2)
6.5 (25 mm2)

9.5 (35 mm2)


11 (50 mm2)

Feeder terminals

mm2

1.5 ... 25

1.5 ... 35

4 ... 50

Conductor cross-sections
Solid and stranded
mm2
AWG Conductor cross-section, solid and stranded AWG

1.5 ... 25
18 ... 4

1.5 ... 35
14 ... 2

4 ... 50
10 ... 1/0

22B/32 A/400 V AC
22B/10 A/690 V AC

22B/50 A/400 V AC
22B/20 A/690 V AC

20B/690 V AC

50 (32 A gG)

100 (50 A gG)

100 (100 A gG)


80 (80 A gG)

Utilization category

Acc. to IEC 60947-3

Rated conditional short-circuit current


At 400 V

5/58

kA

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR, cylindrical fuse design

Selection and ordering data


Sizes

Ie

Ue

Breaking
I2t value

Power
loss

mm mm

V AC/
V DC

A2s

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Cylindrical fuse links, operational class aR


10 38

14 51

22 58

3
6
8

600/400

8
20
30

1.2
1.5
2

A
}
B

3NC1 003
3NC1 006
3NC1 008

1 10 units
1 10 units
1 10 units

047
047
047

0.008
0.008
0.006

10
12
16

60
110
150

2.5
3
3.5

}
B
}

3NC1 010
3NC1 012
3NC1 016

1 10 units
1 10 units
1 10 units

047
047
047

0.007
0.006
0.009

20
25
32

200
250
500

4.8
6
7.5

}
}
}

3NC1 020
3NC1 025
3NC1 032

1 10 units
1 10 units
1 10 units

047
047
047

0.016
0.008
0.010

1
2
3
4

660/7001)

1.2
10
15
25

5
3
2.5
3

B
}
B
}

3NC1 401
3NC1 402
3NC1 403
3NC1 404

1
1
1
1

10 units
10 units
10 units
10 units

047
047
047
047

0.018
0.020
0.018
0.018

5
6

690/7001)

9
12

1.5
1.5

B
}

3NC1 405
3NC1 406

1 10 units
1 10 units

047
047

0.021
0.022

10
15
20

20
75
120

4
5.5
6

}
}
}

3NC1 410
3NC1 415
3NC1 420

1 10 units
1 10 units
1 10 units

047
047
047

0.019
0.020
0.020

25
30
32

250
300
700

7
9
7.6

}
B
}

3NC1 425
3NC1 430
3NC1 432

1 10 units
1 10 units
1 10 units

047
047
047

0.020
0.020
0.028

40
50

900
1 800

8
9

}
}

3NC1 440
3NC1 450

1 10 units
1 10 units

047
047

0.020
0.001

220
300
450

4.6
5.6
7

B
B
B

3NC2 220
3NC2 225
3NC2 232

1
1
1

5 units
5 units
5 units

047
047
047

0.056
0.053
0.055

700
1 350

8.5
9.5

B
}

3NC2 240
3NC2 250

1
1

5 units
5 units

047
047

0.055
0.056

2 600
5 500
8 000

11
13.5
16

}
}
}

3NC2 263
3NC2 280
3NC2 200

1
1
1

5 units
5 units
5 units

047
047
047

0.051
0.055
0.052

90
100
500

4
5.5
6

B
B
B

3NC1 410-5
3NC1 415-5
3NC1 420-5

1 10 units
1 10 units
1 10 units

047
047
047

0.001
0.001
0.020

25
30
32

400
500
600

7
9
7.6

C
C
B

3NC1 425-5
3NC1 430-5
3NC1 432-5

1 10 units
1 10 units
1 10 units

047
047
047

0.001
0.020
0.022

40
50

900
2 000

8
9

B
B

3NC1 440-5
3NC1 450-5

1 10 units
1 10 units

047
047

0.020
0.020

240
350
500

5
6
8

C
C
B

3NC2 220-5
3NC2 225-5
3NC2 232-5

1 10 units
1
5 units
1
5 units

047
047
047

0.039
0.041
0.057

20
25
32

690/7001)

40
50
63
80
100

600/700

1)

Cylindrical fuse links with striking pin,


operational class aR
14 51

22 58

22 58
1)

10
15
20

20
25
32

690/7001)

690/7001)

40
50

800
1 500

9
9.5

B
B

3NC2 240-5
3NC2 250-5

1
1

5 units
5 units

047
047

0.039
0.058

63
80

3 000
6 000

11
13.5

B
B

3NC2 263-5
3NC2 280-5

1
1

5 units
5 units

047
047

0.040
0.057

8 500

16

3NC2 200-5

5 units

047

0.042

100

600/7001)

DC voltage acc. to UL.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

5/59

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
SITOR, cylindrical fuse design
Sizes

Version

mm mm

Rated voltage

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

V AC

Cylindrical fuse holders


Can be used as fuse switch disconnectors1)

}
}
}

3NC1 091
3NC1 092
3NC1 093

1 12 units
1
6 units
1
4 units

047
047
047

0.067
0.126
0.200

1P
2P
3P

}
}
B

3NC1 491
3NC1 492
3NC1 493

1
1
1

6 units
3 units
2 units

047
047
047

0.102
0.203
0.279

1P
2P
3P

}
}
B

3NC2 291
3NC2 292
3NC2 293

1
1
1

1 unit
3 units
2 units

047
047
047

0.204
0.358
0.512

10 38

1P
2P
3P

14 51

22 58

690

Cylindrical fuse holders


Can be used as fuse switch disconnectors,
with alarm switches for fuse links with striking pin1)
14 51
22 58

1P
1P

690

B
B

3NC1 491-5
3NC2 291-5

1
1

6 units
6 units

047
047

0.130
0.181

10 38

1P
2P
3P

600

B
C
B

3NC1 038-1
3NC1 038-2
3NC1 038-3

1 10 units
1
8 units
1
6 units

047
047
047

0.045
0.074
0.113

14 51
22 58

1P
1P

690

B
B

3NC1 451-1
3NC2 258-1

1
1

3 units
3 units

047
047

0.108
0.225

C
B

3NC1 038
3NC1 451

1 20 units
1 20 units

047
047

0.001
0.118

3NC1 000

047

0.069

Cylindrical fuse bases

Cylindrical fuse clips


For fuses 10 38
For fuses 14 51
Fuse tongs
10 38,
14 51,
22 58

1)

1 unit

Please observe the utilization category and current/voltage values specified in the "Technical specifications" table.

* You can order this quantity or a multiple thereof.

5/60

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
NEOZED and DIAZED design, SILIZED

Overview

Benefits

SILIZED is the brand name of the NEOZED fuses (D0 fuses) and
the DIAZED fuses (D fuses) with super quick characteristic for
semiconductor protection. The fuses are used in combination
with fuse bases, fuse screw caps and accessory parts of the
standard fuse system.
SILIZED fuses protect power semiconductors from the effects of
short-circuits because the super quick disconnect characteristic
is far quicker than that of conventional fuses. They protect expensive devices and system components, such as semiconductor contactors, static relays, converters with fuses in the input
and in the DC link, UPS systems and soft starters for motors
up to 100 A.

SILIZED fuses have an extremely compact design. This


means they have a very small footprint particularly the
NEOZED version.
The rugged and well-known DIAZED design complies with
IEC 60269-3. It is globally renowned and can be used in many
countries.
A huge range of fuse bases and accessories are available for
the NEOZED and DIAZED versions of the SILIZED fuses. This
increases the application options in many devices.

When using fuse bases and fuse screw caps made of molded
plastic, always heed the maximum permissible power loss
values due to the high power loss (power dissipation) of the
SILIZED fuses. When using these components, the following
maximum permissible power loss applies:
NEOZED D02: 5.5 W
DIAZED DII: 4.5 W
DIAZED DIII: 7.0 W
For this reason, sometimes a thermal permanent load of only
50 % is possible.
The DIAZED screw adapter DII for 25 A is used for the 30 A fuse
link.

Technical specifications
SILIZED fuse links,
NEOZED design
5SE1 3
Standards

DIN VDE 0636-3; IEC 60269-3;


DIN VDE 0636-4; IEC 60269-4

Operational class

gR

SILIZED fuse links,


DIAZED design
5SD4

Super quick

Characteristic
Rated voltage Un

V AC
V DC

400
250

500
500

Rated current In

10 ... 63

16 ... 100

Rated breaking capacity

kA AC
kA DC

50
8
Any, but preferably vertical

Mounting position

Using adapter sleeves

Non-interchangeability
Resistance to climate

up to 45 at 95 % rel. humidity

Ambient temperature

-5 ... +40, humidity 90 % at 20

Using screw adapter or adapter sleeves

Siemens LV 10.1 2011

5/61

Siemens AG 2011

Fuse Systems
SITOR Semiconductor Fuses
NEOZED and DIAZED design, SILIZED

Selection and ordering data


Sizes

Ie

Ue

Breaking
I2t value

Power
loss

V AC/
V DC

A2s

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Fuse links, NEOZED design, SILIZED


Operational class gR

D01

10
16

D02

Sizes

400/250

73
120

6.9
6.2

B
B

5SE1 310
5SE1 316

1 10 units
1 10 units

016
016

0.007
0.007

20
25
35

190
215
470

8.1
8.2
16.7

B
B
B

5SE1 320
5SE1 325
5SE1 335

1 10 units
1 10 units
1 10 units

016
016
016

0.012
0.013
0.013

50
63

1 960
4 230

12.0
15.5

B
B

5SE1 350
5SE1 363

1 10 units
1 10 units

016
016

0.017
0.016

DT

Order No.

Ie

Ue

Breaking
I2t value

Power
loss

V AC/
V DC

A2s

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Fuse links, DIAZED design, SILIZED


Operational class gR
DII

16
20
25
30

DIII

DIV

500/500

60
139
205
310

12.1
12.3
12.5
13.5

A
A
A
A

5SD4 20
5SD4 30
5SD4 40
5SD4 80

1
1
1
1

5 units
5 units
5 units
5 units

016
016
016
016

0.028
0.029
0.029
0.031

35
50
63

539
1 250
1 890

14.8
18.5
28

A
A
A

5SD4 50
5SD4 60
5SD4 70

1 5 units
1 5 units
1 5 units

016
016
016

0.047
0.048
0.049

80
100

4 200
8 450

34.3
41.5

B
B

5SD5 10
5SD5 20

1 3 units
1 3 units

016
016

0.131
0.115

* You can order this quantity or a multiple thereof.

5/62

Siemens LV 10.1 2011

Siemens AG 2011

Fuse Systems

Photovoltaic fuses
Cylindrical fuse design

In spite of the lack of uniform international and European standards, cylindrical fuses for photovoltaic applications are already
being deployed in many European countries.

There is still no uniform international or European standard for PV


fuses and fuse holders, but work on integrating the special requirements of these fuses in the IEC 60269 set of standards is in
progress. UL approval for the international market will be available soon.

The fuse inserts have a rated voltage of 1000 V and a high operational class of gPV for the protection of PV modules and their
connecting cables.

The correct selection and dimensioning of these fuses must take


account of the specific operating conditions as well as the data
of the PV modules when calculating the voltage and the current.

Overview

The cylindrical fuse holders can be supplied in single-pole and


two-pole versions with and without signal detectors. In the case
of devices with signal detector, a small electronic device with
LED is located behind an inspection window in the plug-in module. If the inserted fuse link is tripped, this is indicated by the LED
flashing.
The fuse holders size 10 mm x 38 mm have a sliding catch that
enables the removal of individual devices from the assembly.
The infeed can be from the top or the bottom. Because the cylindrical fuse holders are fitted with the same anti-slip terminals at
the top and the bottom, the devices can also be rail-mounted at
the top or the bottom.

Benefits
Protection of the module connection leads and the modules in
case of reverse currents
Safe disconnection in case of fault currents reduces the risk of
fire due to DC electric arcs
Safe isolation when the fuse holder is open
A flashing LED on the fuse holder indicates when the fuse link
disconnects. This enables fast detection during runtime.

The PV cylindrical fuse holders comply with IEC 60269-2 and are
regarded as fuse disconnectors in the sense of the switching
device standard IEC 60947. Under no circumstances are they
suitable for switching loads.

Technical specifications
Cylindrical fuse holders

Cylindrical fuse links


3NW7 0. .-4 cylindrical fuse
holders

Size

mm x mm 10 x 38
IEC 60269, IEC 60269-6 (draft),
IEC 60947

Standards

UL 712 (available soon)

Approvals
Rated voltage Un

V DC

1000

Rated current In

A DC

25

kA

30

Rated short-circuit strength


Switching capacity
Utilization category

AC-20B, DC-20B
(switching without load)

Max. power dissipation of


the fuse link

3.4

Rated impulse withstand


voltage

kV

Overvoltage category

II

Pollution degree

3NW6 0.. -4 cylindrical fuse links


Size

mm x mm 10 x 38

Standards

IEC 60269-6 (draft)

Approvals

UL 248-13 (available soon)


gPV

Operational class
Rated voltage Un

V DC

1000 at time constant (L/R) 3 ms

Rated current In

A DC

4 ... 16

kA DC

30

Rated breaking capacity


Any, but preferably vertical

Mounting position
Ambient temperature

-5 ... +40,
Humidity 90 % at +20

No-voltage changing of fuse links


Yes
Sealable when installed
Yes
Mounting position

Any, but preferably vertical

Current direction

Any (signal detector with antiparallel LED)

Degree of protection acc. to


IEC 60529

IP20, with connected conductors

Terminals are touch-protected according to BGVA3 at the incoming and out- Yes
going feeder
Ambient temperature

Conductor cross-sections
finely stranded, with end sleeve mm2
AWG (American Wire Gauge)
Tightening torques

Nm

-5 ... +40,
Humidity 90 % at +20
0.75 ... 25
18 ... 4
1.2

Siemens LV 10.1 2011

5/63

Siemens AG 2011

Fuse Systems
Photovoltaic fuses

Cylindrical fuse design

Selection and ordering data


Sizes

In

Un

Pv

mm x mm

A DC

V DC

DT

Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Cylindrical fuse links, operational class gPV


10 x 38

4
6
8

1000

10
12
16

Number of
poles

1.4
2.0
1.8

B
B
B

3NW6 004-4
3NW6 001-4
3NW6 008-4

1 10 units
1 10 units
1 10 units

018
018
018

0.008
0.010
0.008

2.5
2.0
2.7

B
B
B

3NW6 003-4
3NW6 006-4
3NW6 005-4

1 10 units
1 10 units
1 10 units

018
018
018

0.010
0.010
0.010

PG

Weight
per PU
approx.

In

For fuse links of size

Mount- DT
ing
width

A DC

mm x mm

MW

Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*/
P. unit

kg

Cylindrical fuse holders with signal detector


1P

25

10 x 38

3NW7 014-4

1 12 units

018

0.007

2P

25

10 x 38

3NW7 024-4

6 units

018

0.014

Cylindrical fuse holders without signal detector


1P

25

10 x 38

3NW7 013-4

1 12 units

018

0.006

2P

25

10 x 38

3NW7 023-4

018

0.013

6 units

* You can order this quantity or a multiple thereof.

5/64

Siemens LV 10.1 2011

Siemens AG 2011

Overvoltage Protection
Devices
6/2

Introduction

6/3

Lightning Arresters, Type 1

6/5

Combination Surge Arresters,


Type 1 and Type 2

6/7

Surge Arresters, Type 2

6/11

Surge Arresters, Type 3

6/12

Accessories for Surge Arresters

6/13

Link Rails

6/14

Configuration

6/16

Surge Arresters for Measuring and


Control Technology
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Overvoltage Protection Devices


Introduction

Field of application

Standards

Used in

Industry

Lightning arresters, type 1

Page

Residential
buildings

Devices

Non-residential
buildings

Overview

6/3

With plug-in protective modules for


TN-C, TN-S and TT systems
Rated voltage 350 V AC for lightning
currents from 25 kA to 100 kA.
All versions with remote signaling
contact.

EN 61643-11

EN 61643-11

EN 61643-11

With plug-in protective modules for


EN 61643-11
single-phase and three-phase systems.
Rated voltage, single-phase
24 V AC/DC, 60 V, 120 V, 230 V and
three-phase 230/400 V AC.

For installation in main distribution


boards, upstream or downstream of the
counter.
Combination surge arresters,
type 1 and type 2

6/5

With plug-in protective modules for


TN-C, TN-S and TT systems.
Rated voltage 350 V AC for lightning
currents from 25 kA to 100 kA.
All versions with remote signaling
contact.
For installation in main distribution
boards downstream of the counter.

Surge arresters, type 2

6/7

With plug-in protective modules for


TN-C, TN-S and TT systems
Rated voltage 350 V AC, rated
discharge surge current 20 kA and
discharge surge current 40 kA.
For installation in sub-distribution
boards.

Surge arresters, type 3

6/11

For installation as close as possible


upstream from the terminal equipment.

6/2

Accessories for surge arresters

6/12

Plug-in parts for lightning and surge


EN 61643-11
arresters and through-type terminals for
installation.

Link rails

6/13

Link rails provide the electrical intercon- -nection of the N conductors, PE conductors or PEN conductors of 1-pole
surge arresters, type 2.

Configuration

6/14

Everything you need to know about


overvoltage protection. Function,
mounting and technical connections.

Surge arresters for measuring and


control technology

6/16

With plug-in protective modules for


measuring and control technology for
installation in signal circuits.

--

Siemens LV 10.1 2011

EN 61643-21

Siemens AG 2011

Overvoltage Protection Devices


Lightning arresters, type 1

Overview

Benefits

Lightning arresters type 1 protect low-voltage systems against


any overvoltage or high impulse currents that may be triggered
by a direct or indirect lightning strike.
The protection level is lowered to 1.5 kV by the lightning arrester.
The lightning arresters are enclosed and are suitable for installation in the precounter area.
All spark gaps are tripped. For this reason, decoupling reactors
are no longer required for the installation of overvoltage protection devices.
The lightning arresters are tested using a wave-shaped 25 kA to
100 kA lightning impulse current with waveform 10/350 s.

The rated arrester voltage is a uniform 350 V AC. This increases safety in systems with extended voltage overshoots.
All lightning arresters are fitted with a mechanical fault indication, which does not require an extra power supply. This
means they can be installed in the precounter area, where
electrical plants can be protected particularly effectively.
The protective modules are plug-in versions. No dismantling
of electrical wires required when replacing the protective
modules. When taking insulation measurements, the protective modules are simply removed in order to ensure disconnection from the power supply.
All lightning arresters have a remote signaling contact, which
signals if the device fails.

Technical specifications
5SD7 411-1

5SD7 413-1

5SD7 414-1

IEC 61643-11; EN 61643-11


-UL/cUL

UL/cUL

UL/cUL

V AC

240

240/415

V AC

350

kA
kA

25
--

25
100

25/75
--

25/75
100

kA
kA

25
--

25
100

25/75
--

25/75
100

kV

 1.5

kA
A

50/25
--

50/25
100

50/25
--

50/25
100

ns
ns

 100
--

 100
 100

 100
--

 100
 100

For parallel connection


For series connection

A
A

315 gL/gG
125 gL/gG

Short-circuit strength with max. back-up fuse

kArms

50

Temperature range

-40 ... +80

Standards
Approvals
Rated voltage UN

5SD7 412-1

Rated arrester voltage UC


L/N, N/PE, L/PEN
Lightning impulse current Iimp (10/350 s)
L/N or L/PEN, 1P/3P
N/PE
Rated discharge surge current In (8/20 s)
L/N or L/PEN, 1P/3P
N/PE
Protection level Up
L/N, N/PE, L/PEN
Follow current discharge capacity Ifi (AC)
L/N or L/PEN
N/PE

for 264 V/350 V

Response time tA
L/N or L/PEN
L-(N)-PE
Max. back-up fuse

Acc. to IEC 61643-11

IP20, with connected conductors

Degree of protection
Conductor cross-section
Finely stranded
Solid
Mounting width

Acc. to DIN 43880

mm2
mm2

2.5 ... 25
2.5 ... 35

MW

Contact type
Operational voltage, max.

Yes

Remote signaling (RS)


V AC
V DC

Floating CO contact (plug-in)


250
125

Operational current, max.


- Resistive/inductive load
- Resistive/inductive load

A AC
1/1
mA DC 200/30

Conductor cross-section
- Finely stranded
- Solid

mm2
mm2

1.5
1.5

Siemens LV 10.1 2011

6/3

Siemens AG 2011

Overvoltage Protection Devices


Lightning arresters, type 1

Selection and ordering data


Version

Discharge
capacity

Mount- DT
ing
width

kA

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Lightning arresters

1P
25
For single-conductor systems
With remote signaling

5SD7 411-1

1 unit

008

0.424

2P
For TN-S and TT systems
With remote signaling

100

5SD7 412-1

1 unit

008

0.808

3P
For TN-C systems
With remote signaling

75

5SD7 413-1

1 unit

008

1.221

4P
For TN-S and TT systems
With remote signaling

100

5SD7 414-1

1 unit

008

1.609

* You can order this quantity or a multiple thereof.

6/4

Siemens LV 10.1 2011

Siemens AG 2011

Overvoltage Protection Devices


Combination surge arresters, type 1 and type 2

Overview

Benefits

Combination surge arresters type 1 and type 2 protect lowvoltage systems against the overvoltages and high currents
triggered by direct lightning strikes. They are tested by waveshaped lightning impulse, 25 KA to 100 kA with waveform
10/350 s.
The protection level is lowered to 1.5 kV by the combination
surge arresters.
A thermal isolating arrester disconnector offers a high degree of
protection against overload.
All spark gaps are tripped. For this reason, decoupling reactors
are no longer required for the installation of overvoltage protection devices.

The rated arrester voltage is a uniform 350 V AC. This increases safety in systems with extended voltage overshoots.
All combination surge arresters are fitted with a mechanical
fault indication, which does not require an extra power supply.
The protective modules are plug-in versions. No dismantling
of electrical wires required when replacing the protective
modules. When taking insulation measurements, the protective modules are simply removed in order to ensure disconnection from the power supply.
The same type 2 overvoltage protective modules are used as
for the slim version of the surge arresters (5SD7 42.). This
simplifies stock-keeping.
All combination surge arresters have a remote signaling
contact, which signals if the device fails.

Technical specifications
5SD7 441-1

5SD7 443-1

5SD7 444-1

IEC 61643-11; EN 61643-11


-KEMA, UL/cUL

KEMA, UL/cUL

KEMA, UL/cUL

V AC

240

240/415

V AC

350

kA
kA

25
--

25
100

25/75
--

25/75
100

kA
kA

25
--

25
100

25/75
--

25/75
100

kV

 1.5

kA
kA

25
--

25
100

25
--

25
100

ns
ns

 25
--

 100
 100

 100
--

 100
 100

For parallel connection


For series connection

A
A

315 gL/gG
125 gL/gG

Short-circuit strength with max. back-up fuse

kArms

25

Temperature range

-40 ... +80

Standards
Approvals
Rated voltage UN

5SD7 442-1

Rated arrester voltage UC


L/N, N/PE, L/PEN
Lightning impulse current Iimp (10/350 s)
L/N or L/PEN, 1P/3P
N/PE
Rated discharge surge current In (8/20 s)
L/N or L/PEN, 1P/3P
N/PE
Protection level Up
L/N, N/PE, L/PEN
Follow current discharge capacity Ifi (AC)
L/N or L/PEN
N/PE
Response time tA
L/N or L/PEN
L-(N)-PE
Max. back-up fuse

Acc. to IEC 61643-11

IP20, with connected conductors

Degree of protection
Conductor cross-section
Finely stranded
Solid
Mounting width

Acc. to DIN 43880

mm2
mm2

2.5 ... 25
2.5 ... 35

MW

Visual function/fault indication

Yes

Remote signaling (RS)

Yes

Contact type
Operational voltage, max.

V AC
V DC

Floating CO contact (plug-in)


250
125

Operational current, max.


- Resistive/inductive load
- Resistive/inductive load

A AC
1/1
mA DC 200/30

Conductor cross-section
- Finely stranded
- Solid

mm2
mm2

1.5
1.5

Siemens LV 10.1 2011

6/5

Siemens AG 2011

Overvoltage Protection Devices


Combination surge arresters, type 1 and type 2

Selection and ordering data


Version

Discharge
capacity

Mount- DT
ing
width

kA

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Combination surge arresters

1P
25
For single-conductor systems
With remote signaling

5SD7 441-1

1 unit

008

0.356

2P
For TN-S and TT systems
With remote signaling

100

5SD7 442-1

1 unit

008

0.741

3P
For TN-C systems
With remote signaling

75

5SD7 443-1

1 unit

008

1.004

4P
For TN-S and TT systems
With remote signaling

100

5SD7 444-1

1 unit

008

1.403

* You can order this quantity or a multiple thereof.

6/6

Siemens LV 10.1 2011

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters, type 2

Overview

Benefits

Surge arresters type 2 are used downstream of lightning arresters type 1 in main distribution boards or sub-distribution boards.
They protect low-voltage systems against transient overvoltages.
The type 2 surge arrester lowers the protection level to
1.4 / 1.5 kV. A remote signaling contact signals whether a
protective module has been disconnected from the network
by the thermal arrester disconnector or whether it is just not
plugged in.
All spark gaps are tripped. For this reason, decoupling reactors
are no longer required for the installation of overvoltage protection devices.
To ensure fault-free operation of photovoltaic systems, it is
essential to have standardized protection against lightning and
overvoltages. SPDs (5SD7 483-.) on the DC side protect the
photovoltaic generator and the inverter against overvoltages.

The rated arrester voltage is a uniform 350 V AC. This increases safety in systems with extended voltage overshoots.
All type 2 surge arresters are fitted with a mechanical fault
indication, which does not require an extra power supply.
A thermal isolating arrester installed in each device offers a
high degree of protection. In the event of overload, the surge
arrester is disconnected from the mains - the plant continues
running
The protective modules are plug-in versions. No dismantling
of electrical wires required when replacing the protective
modules. When taking insulation measurements, the protective modules are simply removed in order to ensure disconnection from the power supply.
All surge arresters are available with a remote signaling
contact, which signals if the device fails.

The SPDs 5SD7 473-. and 5SD7 485-. are especially available
for protecting IT systems.

Technical specifications
Surge arresters, standard design
N/PE

Single-pole

Multipole

Plug-in

Plug-in

3P

4P

3P

4P

3P

5SD7 481-0

5SD7 461-.

5SD7 463-.

5SD7 464-.

5SD7 473-.

5SD7 485-.

5SD7 483-.

IEC 61643-11; EN 61643-11


KEMA
--

Standards
Approvals
V AC

240

240

240/415

240/415

500

240/415

--

L/N

V AC

--

350

--

--

--

--

--

L/N or L/PEN
N/PE

V
V AC

-260

---

350 AC
--

350 AC
260

580 AC
--

440 AC
--

1000 DC
--

L/N

kA

--

20

--

--

--

--

--

L/N or L/PEN, 1P
N/PE

kA
kA

-20

---

20
--

20
20

15
--

20
--

15
--

Rated voltage UN
Rated arrester voltage UC

Rated discharge surge current In (8/20 s)

Max. discharge surge current Imax (8/20 s)


L/N

kA

--

40

--

--

--

--

--

L/N or L/PEN, 1P

kA

--

--

40

40

--

--

30

L/N or L/PEN, 1P/multipole


N/PE

kA
kA

-40

---

---

-40

30
--

40
--

---

Lightning impulse current Iimp (10/350 s)

kA

12

--

kV
kV

- 1.5

 1.4
--

 1.4
--

 1.4
 1.5

 2.5
--

 2.2
--

5
--

ns
ns

- 100

 25
--

 25
--

 25
 100

 25
--

 25
--

 25
--

Protection level Up
L/N or L/PEN
N/PE
Response time tA
L/N or L/PEN
N/PE
Max. back-up fuse

Acc. to IEC 61643-11

For parallel connection


For series connection

A
A

125 gL/gG
63 gL/gG

Short-circuit strength
with max. back-up fuse

kArms

25

Temperature range

-40 ... +80


IP20, with connected conductors

Degree of protection
Conductor cross-section
Finely stranded
Solid

mm2
mm2

1.5 ... 25
1.5 ... 35

Mounting width according to DIN 43880

MW

Visual function/fault indication

Yes

Siemens LV 10.1 2011

6/7

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters, type 2
Multipole surge arresters, narrow design
5SD7 422-0 5SD7 422-1 5SD7 423-0 5SD7 423-1 5SD7 424-0 5SD7 424-1
IEC 61643-11; DIN VDE 06754-6
KEMA
KEMA/
KEMA
UL/cUL

Standards
Approvals

KEMA/
UL/cUL

KEMA

V AC

240

240/415

240/415

V AC
V AC

350
264

350
--

350
264

kA
kA

20
20

20
--

20
20

kA
kA

40
40

40
--

40
40

kV
kV

 1.4
 1.5

 1.4
--

 1.4
 1.5

ns
ns

 25
 100

 25
--

 25
 100

For parallel connection


For series connection

A
A

125 gL/gG
63 gL/gG

Short-circuit strength with max. back-up fuse

kArms

25

25

25

Temperature range

-40 ... +80

Rated voltage UN
Rated arrester voltage UC
L/N or L/PEN
N/PE
Rated discharge surge current In (8/20 s)
L/N or L/PEN, 1P/3P
N/PE

Max. discharge surge current Imax (8/20 s)


L/N or L/PEN, 1P/3P
N/PE
Protection level Up
L/N or L/PEN
N/PE
Response time tA
L/N
N/PE
Max. back-up fuse

Acc. to IEC 61643-11

IP20, with connected conductors

Degree of protection
Conductor cross-section
Finely stranded
Solid
Mounting width

Acc. to DIN 43880

mm2
mm2

1.5 ... 16
1.5 ... 25

mm

26

38

Yes

Visual function/fault indication

Remote signaling contact


Yes

Remote signaling (RS)

Floating CO contact (plug-in)

Contact type
Operational voltage, max.

V AC
V DC

250
125

Operational current, max.


Resistive/inductive load
Resistive/inductive load

A AC
1/1
mA DC 200/30

Conductor cross-section
Finely stranded
Solid

mm2
mm2

6/8

Siemens LV 10.1 2011

1.5
1.5

50

KEMA/
UL/cUL

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters, type 2

Selection and ordering data


Version

Discharge
Mounting DT
surge current width
In/Imax
kA

MW

20/40
20/40

1
1

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Surge arresters,
standard design
1P, plug-in
- Without remote signaling
- With remote signaling

A
A

5SD7 461-0
5SD7 461-1

1
1

1 unit
1 unit

008
008

0.133
0.139

6
N/PE, 1P, plug-in
- Without remote signaling

20/40

5SD7 481-0

1 unit

008

0.122

20/40
20/40

3
3

A
B

5SD7 463-0
5SD7 463-1

1
1

1 unit
1 unit

008
008

0.362
0.371

15/30
15/30

3
3

A
A

5SD7 483-0
5SD7 483-1

1
1 unit
1 1/44 units

008
008

0.344
0.352

20/40
20/40

4
4

A
A

5SD7 464-0
5SD7 464-1

1
1

008
008

0.426
0.432

3P, plug-in, 3+0 circuit


For TN-C systems
- Without remote signaling
- With remote signaling

3P, plug-in
For protecting the DC part of the photovoltaic
systems up to 1000 V DC acc. to IEC 60364-7712
- Without remote signaling
- With remote signaling

4P, plug-in, 3+1 circuit


For TN-S and TT systems
- Without remote signaling
- With remote signaling

1 unit
1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

6/9

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters, type 2
Version

Discharge
Mounting DT
surge current width
In/Imax

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

kA

MW

15/30
15/30

3
3

A
A

5SD7 473-0
5SD7 473-1

1
1

1 unit
1 unit

008
008

0.384
0.371

4
4

A
A

5SD7 485-0
5SD7 485-1

1 1/44 units
1
1 unit

008
008

0.445
0.455

PG

Weight
per PU
approx.

Surge arresters,
standard design
3P, plug-in, 3+0 circuit
For IT systems
- Without remote signaling
- With remote signaling

6
4P, plug-in, 4+0 circuit
For IT systems with N-conductor incorporated in
the cable
- Without remote signaling
- With remote signaling

Version

20/40
20/40

Discharge
Mounting DT
surge current width
In/Imax

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

kg

kA

mm (MW)

20/40
20/40

24 (1 1/3) A
24 (1 1/3) B

5SD7 422-0
5SD7 422-1

1
1

1 unit
1 unit

008
008

0.220
0.229

20/40
20/40

36 (2)
36 (2)

A
B

5SD7 423-0
5SD7 423-1

1
1

1 unit
1 unit

008
008

0.320
0.317

20/40
20/40

48 (2 2/3) A
48 (2 2/3) A

5SD7 424-0
5SD7 424-1

1
1

1 unit
1 unit

008
008

0.407
0.423

Surge arresters,
narrow design
2P
For TN-S and TT systems
- Without remote signaling
- With remote signaling

3P
For TN-C systems
- Without remote signaling
- With remote signaling

4P
For TN-S and TT systems
- Without remote signaling
- With remote signaling

* You can order this quantity or a multiple thereof.

6/10

Siemens LV 10.1 2011

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters, type 3

Overview

Benefits
The protective modules are plug-in versions. No mounting
work required when replacing the protective modules
All type 3 surge arresters are fitted with a fault indication,
which does not require an extra power supply
In the event of a power failure, a remote signaling is output
over an optocoupler with open collector output.

Type 3 surge arresters are installed after the type 2 surge arresters in sub-distribution boards close to the loads in single or
multiphase systems and further limit the overvoltage in order to
protect the connected loads.

Technical specifications
Multipole surge arresters, plug-in
2P
Standards
Approvals

5SD7 432-2

5SD7 432-3

IEC 61643-11; EN 61643-11


KEMA

--

5SD7 432-4

5SD7 434-1
KEMA

Rated voltage UN

V AC

230

120

60

24

230/400

Rated load current IL (at 30 C)

26

26

26

26

3 26

Rated arrester voltage UC

V AC

253

150

100

34

335

Rated discharge surge current In (8/20 s)

kA

2.5

2.5

1.5

Max. discharge surge current Imax (8/20 s)

kA

10

10

6.5

4.5

Combined surge Uoc

kV

 1500/ 600

 850/ 350

 700/ 250

 550/ 100

 1200

Response time tA

ns

 100

 100

 100

 100

 100

Required back-up fuse, max.

25 gL/gG

25 gL/gG

25 gL/gG

25 gL/gG

25 gL/gG

Temperature range

-40 ... +85

LN/L(N)PE

Protection level Up

4P

5SD7 432-1

IP20, with connected conductors

Degree of protection
Conductor cross-section
Finely stranded
Solid
Acc. to DIN 43880

Mounting width

mm2
mm2

0.2 ... 4
0.2 ... 2.5

MW

Visual function/fault indication

Yes

Remote signaling (RS)

Yes

Contact type
Operational voltage, max.
Operational current, max.

V AC

NC contacts
250
3

Selection and ordering data


Version

Rated voltage
UN

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

MW

24

5SD7 432-4

1 unit

008

0.086

60

5SD7 432-3

1 unit

008

0.087

120

5SD7 432-2

1 unit

008

0.089

230

5SD7 432-1

1 unit

008

0.087

230/400

5SD7 434-1

1 unit

008

0.135

kg

Surge arresters, plug-in


2P
With remote signaling

4P
With remote signaling

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

6/11

Siemens AG 2011

Overvoltage Protection Devices


Accessories for surge arresters

Selection and ordering data


Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Plug-in parts for lightning arresters type 1 and


combination surge arresters type 1 and type 2
Lightning arresters L/N Ifi 50 kArms
for 5SD7 41 lightning arresters.
Lightning arresters N/PE
for 5SD7 41. lightning arresters and 5SD7 44.
combination surge arresters.

5SD7 418-1

1 unit

008

0.270

5SD7 418-0

1 unit

008

0.254

B
B

5SD7 448-1
5SD7 418-0

1
1

1 unit
1 unit

008
008

0.148
0.254

5SD7 428-1

1 unit

008

0.069

5SD7 428-0

1 unit

008

0.067

B
B

5SD7 468-1
5SD7 488-0

1
1

1 unit
1 unit

008
008

0.066
0.056

5SD7 488-1

1 unit

008

0.053

5SD7 498-1

1 unit

008

0.065

Rated voltage UN = 230 V

5SD7 437-1

1 unit

008

0.042

Rated voltage UN = 120 V

5SD7 437-2

1 unit

008

0.041

Rated voltage UN = 60 V

5SD7 437-3

1 unit

008

0.041

Rated voltage UN = 24 V

5SD7 437-4

1 unit

008

0.042

Plug-in parts for 5SD7 434-1 surge arresters,


type 3

5SD7 438-1

1 unit

008

0.060

Plug-in parts for lightning arresters type 1 and


combination surge arresters type 1 and type 2
Lightning arresters L/N Ifi 50 kArms
Lightning arresters N/PE
for 5SD7 41. lightning arresters and 5SD7 44.
combination surge arresters.
Plug-in parts for surge arresters type 2 and
combination surge arresters type 1 and type 2
Surge arresters L/N
for 5SD7 42. surge arresters and 5SD7 44.
combination surge arresters.
Lightning arresters N/PE
for 5SD7 41. lightning arresters and 5SD7 44.
combination surge arresters.
Plug-in parts for 5SD7 46. surge arresters,
type 2
Surge arresters L/N
Surge arresters N/PE

Plug-in parts for 5SD7 485-. surge arresters,


type 2
Surge arresters for IT systems

Plug-in parts for 5SD7 473-. and 5SD7 483-.


surge arresters, type 2
Surge arresters for photovoltaics and
IT systems

Plug-in parts for 5SD7 432-. surge arresters,


type 3

* You can order this quantity or a multiple thereof.

6/12

Siemens LV 10.1 2011

Siemens AG 2011

Overvoltage Protection Devices


Link rails

Overview

Benefits

Link rails let you combine 1-pole surge arresters to create


complete solutions for multiphase systems.

These link rails allow cable lengths to be reduced to a minimum


and save time during mounting.

Technical specifications
Link rails
5SD7 490-2, 5SD7 490-3, 5SD7 490-4
Standards

EN 60439-1

Busbar material

SF-Cu F 24

Plastic, cycolor 3600 temperature resistant  90 C

Partition material
Busbar cross-section

mm2

16

Rated operational voltage Uc

V AC

400

Cross-section 16 mm2

80

Rated impulse withstand voltage Uimp

kV

Test pulse voltage (1.2/50)

kV

6.2

Rated conditional short-circuit current Icc

kA

25

Rated current In

Resistance to climate
Constant atmosphere acc. to DIN 50015
Humid heat (acc. to IEC 68, Part 2-30)

23/83; 40/92; 55/20


28 cycles

Insulation coordination according to IEC 60664-1


Overvoltage category
Pollution degree

III
2

Maximum busbar current Is/phase


Cross-section 16 mm2

80

130

Maximum current in the arm IE/phase


Cross-section 16 mm2

Selection and ordering data


Version

Linking
sequence

Length

MW

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Link rails for the interconnection of single-pole


surge arresters, type 2
2-pole

34

5SD7 490-2

10/100 units

008

0.093

3-pole

51.8

5SD7 490-3

10/100 units

008

0.143

4-pole

69.6

5SD7 490-4

10/100 units

008

0.194

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

6/13

Siemens AG 2011

Overvoltage Protection Devices


Configuration

More information
Selection of overvoltage protection devices
Situation

Systems

Which type of building do you


want to protect?
Generally speaking, all our
devices are suitable for residential buildings, office buildings, industrial and commercial
buildings.
Low risk buildings

Basic protection
For installation upstream of counters in main distribution boards
or in combined main/sub-distribution boards

TN-S and TT systems

Surge arresters, type 2


Narrow design
5SD7 424-0, 5SD7 424-1

Wide design
5SD7 464-0, 5SD7 464-1
With or without remote signaling

- No outer lightning protection


- Power supply
over ground conductor

TN-C systems

Surge arresters, type 2


Narrow design
5SD7 423-0, 5SD7 423-1
Wide design
5SD7 463-0, 5SD7 463-1
With or without remote signaling

High-risk buildings

TN-S and TT systems

Lightning arresters, type 1


5SD7 414-1
With remote signaling

- Outer lightning protection


system

TN-C systems

Lightning arresters, type 1


5SD7 413-1
With remote signaling
5SD7411-1

TN-S and TT systems

Combination surge arresters, type 1 and type 2


5SD7 444-1

- Power supply
over overhead lines

With remote signaling

TN-C systems

Combination surge arresters, type 1 and type 2


5SD7 443-1

- Grounded aerial structures

With remote signaling


5SD7441-1

IT systems
without N-conductor incorporated in the
cable

IT systems
with N-conductor incorporated in the
cable

6/14

Siemens LV 10.1 2011

Typically, IT systems are only installed in special


building sections. There are generally still TN-C,
TN-S or TT systems in the area of the main
distribution board. In this case, the protective
devices shown above must be installed.

Siemens AG 2011

Overvoltage Protection Devices


Configuration

Medium protection

Fine protection

For installation upstream of counters in main distribution boards


or in combined main/sub-distribution boards

For installation directly upstream of the terminal equipment

Surge arresters, type 2

Surge arresters, type 3

Narrow design
5SD7 424-0, 5SD7 424-1

For installation in sub-distribution boards


or control cabinets

Standard design
5SD7 464-0, 5SD7 464-1

5SD7 432-x and 5SD7 434-1


With remote signaling

With or without remote signaling


Only required if the distance between the main and sub-distribution boards is > 10 m
Surge arresters, type 2
Narrow design
5SD7 423-0, 5SD7 423-1
Standard design
5SD7 463-0, 5SD7 463-1
With or without remote signaling
Only required if the distance between the main and sub-distribution boards is > 10 m
Surge arresters, type 2
Narrow design
5SD7 424-0, 5SD7 424-1
Standard design
5SD7 464-0, 5SD7 464-1
With or without remote signaling
Surge arresters, type 2
Narrow design
5SD7 423-0, 5SD7 423-1
Standard design
5SD7 463-0, 5SD7 463-1
With or without remote signaling
Surge arresters, type 2
Narrow design
5SD7 424-0, 5SD7 424-1
Standard design
5SD7 464-0, 5SD7 464-1
With or without remote signaling
Only required if the distance between the main and sub-distribution boards is > 10 m
Surge arresters, type 2
Narrow design
5SD7 423-0, 5SD7 423-1
Standard design
5SD7 463-0, 5SD7 463-1
With or without remote signaling
Only required if the distance between the main and sub-distribution boards is > 10 m
Surge arresters, type 2
5SD7 473-0, 5SD7 473-1
3-pole (3+0 circuit)
Uc = 580 V AC
with or without remote signaling
Surge arresters, type 2
5SD7 485-0, 5SD7 485-1
4-pole (4+0 circuit)
Uc = 440 V AC
with or without remote signaling

Siemens LV 10.1 2011

6/15

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters for
measuring and control technology

Overview

Benefits

The surge arresters for measuring and control technology are


overvoltage protection modules that comprise two parts, a basic
element and a plug-in part. Their application area is the protection of signal circuits.
The cable shields of basic elements can be either directly or indirectly grounded.
The mounting width of the new surge arrester is 1 MW.
Through the number of integrated paths, it is possible to protect
up to four signal cores or two double cores against overvoltages.

The two-component design offers users maximum maintenance convenience. The basic element is always a fixed integral part of the installation. There are therefore no laborious
access problems during repair work, etc.
The benefits:
- Two-part design comprising plug-in part and basic element
- Interruption-free and impedance neutral plugging in and
pulling out of the plug-in part
- Reverse polarity protection through mechanical encoding
- An electric surge voltage resistant connection is made automatically when it is snapped onto the standard mounting
rail no laborious wiring of ground.
The arrangement of suppressor diodes between signal cores
achieves a fine protection in connection with a fast response.
The low-limiting coupling of the suppressor diodes to the signal cores supports fast data transmission rates.
The use of gas-filled surge arresters ensures a high discharge
capacity.

Technical specifications
5SD7 502-0
IEC category/EN type

5SD7 520-1

5SD7 522-7

5SD7 530-3

5SD7 541-7

5SD7 550-4

C1/C2/C3/D1 C1/C2/C3/
D1/B2

C1/C2/C3/D1 C1/C2/C3/D1 C1/C2/C3/D1 C1/C2/C3/D1

Max. continuous voltage UC


Direct voltage
AC voltage

V DC
V AC

68
48

185
130

40
28

5.2
3.6

40
28

14
9.8

Rated current IN

mA

2000

450

450

450

300

450

Lightning test current Iimp 10/350 s Per path

kA

--

2.5

2.5

2.5

2.5

kA
kA

-20

10
10

10
10

10
10

-10

10
10

kA

40

10

20

20

20

20

V
V

- 600

 300
 300

 55
 450

 15
 15

- 55

 25
 25

Core - Core

--

 15

--

 25

--

 160
(C2/5 kA)
 160
(C2/5 kA)

 55

Core - Ground

--

 30

 55

 40

ns
ns

- 100

 500
 500

1
 100

 500
 500

-1

 500
 500

Symmetrical in the 50- system

dB

--

--

--

--

--

Asymmetrical in the 50- system


Symmetrical in the 100- system

dB
dB

0.1 (1 MHz)
--

-Typ. 0.2
(5 MHz)

Typ. 0.5
(1.5 MHz)
---

-0.2 (5 MHz)

0.5 (1.5 MHz) --0.2 (5 MHz)

MHz
MHz
MHz

----

--Typ. 70

Typ. 8
---

--Typ. 70

-Typ. 8
--

--Typ. 70

Resistor per path

--

--

2.2

2.2

4.7

2.2

Temperature range

-40 ... +85

Rated discharge current In

8/20 s

Core - Core
Core - Ground
Total surge current IN

8/20 s

Output voltage limit at 1 kV/s


Core - Core
Core - Ground
Residual voltage at In

Response time tA
Core - Core
Core - Ground
Insertion loss A E

Limit frequency fG (3 dB)


Symmetrical in the 50- system
Asymmetrical in the 50- system
Symmetrical in the 100- system

Degree of protection acc. to IEC 60529/EN 60529

IP20

Flammability class acc. to UL 94

V0

Test standards

EN 61643-21

6/16

Siemens LV 10.1 2011

IEC 61643-21 EN 61643-21

IEC 61643-21 EN 61643-21

IEC 61643-21

Siemens AG 2011

Overvoltage Protection Devices


Surge arresters for
measuring and control technology
Combination options for basic elements and plug-in parts
Plug-in part
Basic elements

5SD7 502-0

5SD7 520-1

5SD7 522-7

5SD7 530-3

5SD7 541-7

5SD7 550-4

5SD7 500-0

--

--

--

--

--

5SD7 512-1

--

--

--

--

5SD7 522-0

--

--

--

--

5SD7 522-1

--

--

--

--

5SD7 541-1

--

--

--

--

--

Selection and ordering data


Version

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW
Basic elements
For plug-in parts with protection circuit for a
2-wire ungrounded signal circuit

5SD7 512-1

1 unit

008

0.052

5SD7 522-1

1 unit

008

0.056

5SD7 522-0

1 unit

008

0.057

For plug-in parts with protection circuit for four con- 1


ductors single-sided grounded signal circuit

5SD7 541-1

1 unit

008

0.056

5SD7 500-0

1 unit

008

0.050

5SD7 530-3

1 unit

008

0.020

5SD7 520-1

1 unit

008

0.020

5SD7 522-7

1 unit

008

0.024

5SD7 550-4

1 unit

008

0.026

5SD7 541-7

1 unit

008

0.026

5SD7 502-0

1 unit

008

0.020

Jumper between terminals 3/4 (GND) and 9/10


For 5SD7 520-1 and 5SD7 530-3 plug-in parts
For plug-in parts with protection circuit for a
2-wire ungrounded signal circuit
Jumper between terminals 3/4 (GND) and 9/10
For 5SD7 522-1 and 5SD7 550-4 plug-in parts
For plug-in parts with protection circuit for a
2-wire ungrounded signal circuit
Gas arrester between terminals 3/4 (GND) and 9/10
For 5SD7 522-1 and 5SD7 550-4 plug-in parts

Jumper between terminals 3/4 (GND) and 9/10


For 5SD7 541-7 plug-in parts
Jumper between terminals 3/4 (GND) and 9/10
For 5SD7 502-0 plug-in parts
Plug-in parts - PROFIBUS
Protection for 2 signal cores with shared reference
potential
For 5SD7 512-1 basic element
Plug-in parts for analog telecommunication
interfaces
Protection for 2-wire Telecom cable
(Uk0 or T-DSL)
For 5SD7 512-1 basic element
Plug-in parts, 24 V AC
Protection for 2-wire ungrounded signal circuit.
Miniature protection element between the connected
cores
For 5SD7 522-0 and 5SD7 522-1 basic elements
Plug-in parts, 12 V DC
Protection for field bus systems and signal circuits in
3- or 4-wire method
For 5SD7 522-0 and 5SD7 522-1 basic elements
Plug-in parts, 24 V DC
Protection for 4 signal cores with shared reference
potential
For 5SD7 541-1 basic element
Plug-in parts, 2-wire
Coarse protection for 2 single-sided signal leads
For 5SD7 500-0 basic element

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

6/17

Siemens AG 2011

Overvoltage Protection Devices


Notes

6/18

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
7/2

Introduction

7/3
7/6
7/11
7/16
7/18
7/20
7/21

SENTRON 3LD Main and


EMERGENCY-STOP Switches
up to 250 A
Introduction
Front mounting
Floor mounting
Distribution board mounting
Molded-plastic enclosures
DC applications
Accessories

7/26
7/27

5TE1 Switch Disconnectors


up to 200 A
Introduction
General data

7/31
7/34
7/39
7/40

SENTRON 3KA, 3KE Switch


Disconnectors up to 1000 A
Introduction
Floor mounting
Molded-plastic enclosures
Accessories

7/43
7/45
7/47
7/48

SENTRON 3KL Switch


Disconnectors with Fuses
up to 800 A
Introduction
Floor mounting
Front mounting
Accessories

7/52
7/54
7/55

SENTRON 3KM Switch


Disconnectors with Fuses and
Isolating Plug Connector
up to 400 A
Introduction
For snapping onto busbars
Accessories

7/57
7/62
7/63

7/64
7/69
7/71
7/73
7/82

8UC Door-Coupling Rotary


Operating Mechanisms
For 3K switch disconnectors
Individual parts
Operating mechanisms for fixed
mounting

7/89
7/92
7/94
7/96
7/98

SENTRON 3NP1 Fuse Switch


Disconnectors up to 630 A
Introduction
Floor mounting
For 40 mm busbar system
For 60 mm busbar system
Accessories

7/106
7/108
7/109
7/109
7/110
7/114
7/117

SENTRON 3NP5 Fuse Switch


Disconnectors up to 630 A
Introduction
Floor mounting
For 40 mm busbar system
For 60 mm busbar system
With fuse monitoring
Accessories
Assembly kits for distribution systems

7/118
7/121
7/122
7/123

SENTRON 3NJ4, 3NJ5 In-Line Fuse


Switch Disconnectors up to 2000 A
Introduction
1-pole switchable
3-pole switchable
Accessories

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical Specifications
under Entry List:
- Updates
- Download
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/configurators
- Configurators

SENTRON 3NJ62 In-Line Switch


Disconnectors with Fuses
up to 630 A
Introduction
For LV HRC fuse links
For BS fuse links
For LV HRC and BS fuse links
Accessories

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
Introduction

Overview
Order No.

Page

3LD

7/3

5TE1

7/26

3KA, 3KE

7/31

3KL, 3KM

7/43

3NJ62

7/64

3NP1 / 3NP5

7/89

3NJ4, 3NJ5

7/118

Switch disconnectors
Main and EMERGENCY-STOP switches 16 A to 250 A
Devices for front mounting, floor mounting with door-coupling rotary operating
mechanism, distribution board mounting or in molded-plastic enclosures
Front mounting with four-hole and center hole arrangement
3-, 4- and 6-pole versions
3LD

3- and 4-pole load transfer switches


Solar plant isolators 800 V DC
100 A Switch Disconnectors up to 200 A
For floor and distribution board mounting
2-, 3- and 4-pole versions

5TE1
63 A switch disconnectors up to 1000 A
Devices for floor mounting with handle, with door-coupling rotary operating
mechanism, in molded-plastic enclosures and for mounting in control cabinet
side panels
3- and 4-pole versions
3KA/3KE

Accessories for use as load transfer switches and parallel switches

Switch Disconnectors with Fuses


Switch disconnectors with fuses up to 800 A
Devices for floor mounting with door-coupling rotary operating mechanism and for
mounting in control cabinet side panels
3KM versions with isolating plug connector for mounting on vertical busbars
3- and 4-pole versions
3KL

Suitable for NH and BS 88 fuse systems


In-line switch disconnectors with fuses, plug-in type, up to 630 A
2-, 3- and 4-pole versions
Suitable for NH and BS 88 fuse systems

3NJ62

Manually operated or with motorized operating mechanism


Optionally with integrated current transformers, auxiliary switches and electronic
fuse monitoring

Fuse switch disconnectors


Fuse switch disconnectors up to 630 A
Connection components are available for flat connection, saddle terminal connection, prism terminal connection and box terminal connection
Electromechanical and electronic fuse monitoring with/without network monitoring
function
Mounting variants for floor mounting and 40/60mm busbar system
3NP1
In-line fuse switch disconnectors up to 2000 A
1- and 3-pole switchable versions
Versions for secondary-side fusing of transformers
In-line incoming versions up to 2000 A with isolating links
Connection components are available for flat connection, stud bolt connection, saddle terminal connection, prism terminal connection and box terminal connection
Versions with/without integratable current transformer
Versions with/without electronic fuse monitoring

3NJ4/3NJ5

7/2

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Introduction

Overview

7
3
8

7
6
3
1

NSG0_00112a

4th contact (N conductor)

N or PE/ground terminal, continuous

Auxiliary switch 1 NO + 1 NC

Rotary operating mechanism, red/yellow

Rotary operating mechanism, black

Front plate, English/German

Terminal cover, three-pole

Terminal cover, single-pole

The 3LD main and EMERGENCY-STOP switches are manually


operated switch disconnectors according to IEC 60947-3/
EN 60947-3 and comply with the conditions for switch disconnectors.
In EN 60204-1, main control switches are called "disconnector
units", while EMERGENCY-STOP switches are termed "devices
for emergency shutdown".

The 3LD switches for 16 to 250 A are approved according to


UL 508 and can be used as "manual motor controllers" and
"motor disconnects".
Maintenance personnel can protect themselves against unauthorized startup with padlocks (up to three can be fitted).
The 3LD switches can be used in any mounting position.

Application
The 3LD switches are used for switching main and auxiliary circuits, but also for switching induction motors and other loads
during maintenance and repair work.

They can be used as:


ON-OFF switches
EMERGENCY-STOP switches
Main control switches according to EN 60204-1.

Siemens LV 10.1 2011

7/3

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Introduction

Design
Construction of the contacts
Each switch has three adjacent contact elements1). A fourth
leading contact for switching the N conductor, a continuous
PE terminal, an auxiliary switch (1 NO + 1 NC) can be fitted to
each side of the switch. The auxiliary switches operate as leading contacts on opening. On opening, the NO contact opens before the main contacts, so that a contactor carries the switching
capacity in the circuit and the maintenance or safety switch
switches at zero current. On closing, the auxiliary switch
switches later than or at the same time as the main contacts.
Construction of rotary operating mechanisms

The rotary operating mechanisms of the switches for front or


floor mounting are mounted on control cabinet doors, front or
side panels with four-hole or center-hole mounting with a standard diameter of 22.5 mm and operated from the outside. In their
Off position, they can be locked with up to three padlocks with a
hasp thickness of 8 mm. Controls with defeatable door-coupling
rotary operating mechanism are available in addition.
Switch position indicator:
The switch position is clearly marked with direction arrows and
an "O" for OFF and a "I" for ON at the front.
Switches for front mounting:
The switches for front mounting are connected directly to the
rotary operating mechanism through the fixing screws or - in
the case of center-hole mounting - a special-purpose coupling.
Switches for floor mounting:
The switches for floor mounting are snapped onto 35 mm
standard mounting rails according to EN 60715 or screwmounted on mounting plates. The actuators are connected to
the lower section of the switch through a door coupling, which
can be released in its zero position, and a 300 mm long switch
shaft. When the control cabinet door is open, the switch can
be protected against inadvertent operation by removing the
switch shaft from the lower section of the switch.
The mounting depth can be adapted to individual requirements by adjusting the switch shaft length.
Switches for distribution board mounting:
The switches for distribution board mounting are suited for operation in switchboards and for switching inside control cabinets or distributors. They have cap and mounting dimensions
to DIN 43880 and can be fitted under the same cover together
with miniature circuit breakers. The selector switches can be
locked in their Off position with up to 2 padlocks with a hasp
thickness of 6 mm.
Switches in molded-plastic enclosure:
For surface mounting of individual main and EMERGENCYSTOP switches, molded plastic-enclosed switches to degree
of protection IP65 are used. The actuators can be locked in
their Off position with three padlocks with a hasp thickness of
8 mm.
The molded-plastic enclosures each contain an N and/or a PE
terminal.
1)

3LD2 704-0TK53 switch


for front mounting
with rotary operating mechanism

3LD2 222-0TK1 switch


for front mounting
with knob

3LD2 122-7UK01 3-pole


changeover switch
for front mounting with knob

3LD2 103-3VK53 6-pole switch


for front mounting with rotary
operating mechanism

3LD2 144-0TK53 switch


for floor mounting
with rotary operating mechanism
and door coupling

3LD2 530-0TK11 switch


for distribution board mounting
with knob

3LD2 264-0TB5 switch


in molded-plastic enclosure

3LD2 217-1TL13 switch


for floor mounting
with rotary operating mechanism
and defeatable door coupling

3LD2 265-8VQ51-0AF6
solar plant isolator

3LD2 418-0TK13 switch


for floor mounting, 250 A,
with rotary operating mechanism
and door coupling

16 A versions have four contact elements; 3-pole changeover switches


and 6-pole main control switches have six contact elements.

7/4

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Introduction

Technical specifications
IEC 60947-3

Standards
Switches

Type

3LD2 0

Rated insulation voltage Ui

690

Rated operational voltage Ue


Rated frequency

V AC 690
50 ... 60
Hz

Rated impulse withstand voltage Uimp

Rated short-time withstand current (1 s current, rms value)

Short-circuit protection, max. back-up fuse (gG)

3LD2 1

3LD2 2

3LD2 5

3LD2 7

3LD2 8

3LD2 3

3LD2 4

690

690

690

690

690

690

690

690

340

640

640

1260

2000

2000

4000

4000

20

25

40

63

100

125

160

250

Rated conditional short-circuit current with upstream fuses


at AC 50/60Hz, 690V

kArms 50

50

50

50

50

20

50

50

Permissible let-through current of the fuse

kA

3.5

4.5

10

10

15

15

Rated uninterrupted current Iu

16

25

32

63

100

125

160

250

AC-21A load-break switch

Rated operational current Ie A

16

25

32

63

100

125

160

250

AC-3 motor load switches


In-service switching
of individual motors

Rating
At 220 ... 240 V
At 380 ... 440 V
At 660/690 V

kW
kW
kW

3.0
5.5
5.5

4.0
7.5
7.5

5.5
9.5
9.5

11.0
18.5
15.0

18.5
30.0
22.0

22.0
37.0
30.0

35.0
50.0
37.0

55.0
110.0
45.0

AC-23A main control switch


Repair switch
frequent, but not in-service switching
of individual motors

Rating
At 220 ... 240 V
At 380 ... 440 V
At 660/690 V

kW
kW
kW

4.0
7.5
7.5

5.0
9.5
9.5

6.0
11.5
11.5

11.0
22.0
18.5

18.5
37.0
30.0

22.0
45.0
37.0

45.0
75.0
45.0

75.0
132.0
55.0

0.5

1.1

1.8

4.5

7.5

12.0

36.0

36.0

Power loss per conducting path at Ie


Endurance mechanical

Switching cycles

100 000

Switching frequency

1/h

50

Permissible ambient temperature

-25 ... +55

690

Solid or stranded

mm2

1 ... 6

1.5 ... 16 1.5 ... 16 2.5 ... 35 4 ... 50

Finely stranded with end sleeve (max.)

mm2

10

Up to max.

Isolating features

Conductor cross-sections for main conductors 1)

Conductor cross-sections

Copper cable

Torque for terminal

4 ... 50

16 ...185 16 ... 185

10

16

35

35

150

AWG 18 ... 10 14 ... 8

14 ... 8

14 ... 6

12 ... 1

12 ... 1

Nm

2 ... 2.5

2.5 ... 3

2.5 ... 3

2.5 ... 3

9.5 ... 10 9.5 ... 10

Touch protection acc. to EN 50274

1.5 ... 2

2 ... 2.5

150

Yes

Auxiliary switches
Rated insulation voltage Ui

Rated operational voltage Ue

V AC 500
A

10

At 120 V

At 220 ... 240 V

At 380 ... 415 V

1.8

At 500 V

1.4

10

Rated uninterrupted current Iu


Rated operational current Ie, AC-15

500

Short-circuit protection, auxiliary switch,


max. back-up fuse (gG)
Conductor cross-sections for auxiliary conductors
Connection type

Terminals

Solid or stranded

mm2

2 (0.75 ... 2.5). 1 4

Finely stranded with end sleeve

mm2

2 (0.75 ... 1.5) 1 x 2.5

Torque for terminal

Nm

0.8

SENTRON 3LD main and EMERGENCY-STOP switches for UL/CSA


UL/CSA

Standards
Switches

Type 3LD2 0

3LD2 1

3LD2 2

3LD2 5

3LD2 7

3LD2 8

3LD2 3

3LD2 4

Rated operational voltage Ue


Rated uninterrupted current Iu

V AC 600
A
10
A 600
P 600
A
16

600
20
A 600
P 600
25

600
30
A 600
P 600
32

600
60
--63

600
100
--100

600
125
--125

600
160
--160

600
250
--250

3  120 V
240 V
480 V
600 V

HP
HP
HP
HP

1
3
7.5
10

3
7.5
10
15

3
10
20
30

5
15
40
50

10
30
60
75

15
40
75
100

-40
75
75

-50
100
75

1  120 V
240 V

HP
HP

0.5
1.5

2
3

2
3

3
10

---

---

---

---

14 ... 8
2 ... 2.5

14 ... 6
2.5 ... 3

12 ... 1
2.5 ... 3

12 ... 1
2.5 ... 3

1 ... MCM400
10
10

Current rating
Pilot duty

Conventional thermal current Ith


Maximum rated power (AC-3)
Alternating current operating
mechanisms 40 ... 60 Hz

Conductor cross-sections
Torque
1)

Cu cable

AWG 18 ... 10 14 ... 8


Nm 1.5 ... 2 2 ... 2.5

Depending on the cable infeed, only small cross-sections are possible with
devices in molded-plastic enclosures

Siemens LV 10.1 2011

7/5

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Front mounting

Selection and ordering data


Number and version of the
contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main contact Auxiliary con- P/AC-3


elements
tact elements
kW

DT

Order No.

Price
per PU

P/AC-23A Iu/
AC-21A
kW

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Main and EMERGENCY-STOP switches with rotary


operating mechanism/knob-operated mechanism
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
All versions with rotary operating mechanism
Exception: 3LD2 3 and 3LD2 4 with knob-operated mechanism
Including terminal cover for the infeed side
Front plate:
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm 67 mm
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm 67 mm
- 3LD2 3 to 3LD2 4: 96 mm 96 mm

Four-hole mounting

7
3LD2 203-0TK51

--

5.5
7.5
9.5
18.5
30
37
50
110

7.5
9.5
11.5
22.0
37.0
45.0
75.0
132.0

16
25
32
63
100
125
160
250

}
}
}
}
}
A
A
A

3LD2 003-0TK5@
3LD2 103-0TK5@
3LD2 203-0TK5@
3LD2 504-0TK5@
3LD2 704-0TK5@
3LD2 804-0TK5@
3LD2 305-0TK1@
3LD2 405-0TK1@

1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103
103
103

0.207
0.206
0.206
0.424
0.501
0.503
2.100
2.100

3+N

--

5.5
7.5
9.5
18.5

7.5
9.5
11.5
22.0

16
25
32
63

}
A
A
A

3LD2 003-1TL5@
3LD2 103-1TL5@
3LD2 203-1TL5@
3LD2 504-1TL5@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.217
0.243
0.243
0.424

30.0

37.0

100

3LD2 704-0TK5@
+1)
3LD9 280-0B

1 unit

103

0.501

1 unit

103

0.101

37.0

45.0

125

1 unit

103

0.503

3LD2 804-0TK5@
+1)
3LD9 280-0B

1 unit

103

0.101

50
110

75.0
132.0

160
250

A
A

3LD2 305-1TL1@
3LD2 405-1TL1@

1
1

1 unit
1 unit

103
103

2.600
2.600

1 NO + 1 NC 5.5
7.5
9.5
18.5
30.0
37

7.5
9.5
11.5
22.0
37.0
45.0

16
25
32
63
100
125

A
A
A
A
A
A

3LD2 003-1TP5@
3LD2 103-1TP5@
3LD2 203-1TP5@
3LD2 504-1TP5@
3LD2 704-1TP5@
3LD2 804-1TP5@

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

0.250
0.249
0.206
0.424
0.503
0.503

50.0

75.0

160

3LD2 305-0TK1@
+2)
3LD9 200-5B

1 unit

103

2.100

1 unit

103

0.046

110.0

132.0

250

1 unit

103

2.100

3LD2 405-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.046

7.5
9.5

16
25

A
A

3LD2 003-2EP5@
3LD2 103-2EP5@

1
1

1 unit
1 unit

103
103

0.272
0.287

9.5

11.5

32

3LD2 203-1TL5@
+2)
3LD9 200-5B

1 unit

103

0.243

1 unit

103

0.046

18.5

22.0

63

3LD2 504-1TP5@
+1)
3LD9 250-0BA

1 unit

103

0.424

1 unit

103

0.079

30.0

37.0

100

3LD2 704-0TK5@
+1)
3LD9 280-0B
+2)
3LD9 200-5B

1 unit

103

0.501

1 unit

103

0.101

1 unit

103

0.046

3LD2 804-0TK5@
+1)
3LD9 280-0B
+2)
3LD9 200-5B

1 unit

103

0.503

1 unit

103

0.101

1 unit

103

0.046

3LD2 305-1TL1@
+2)
3LD9 200-5B

1 unit

103

2.600

1 unit

103

0.046

3LD2 405-1TL1@
+2)
3LD9 200-5B

1 unit

103

2.600

1 unit

103

0.046

3LD2 704-0TK53

3+N

1 NO + 1 NC 5.5
7.5

}
}
}
}
}
37.0

45.0

125

A
}
}

50.0

75.0

160

110.0

132.0

250

}
}
Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

4. Contact element as N conductor to be ordered separately,


see "Accessories".

2)

>
1
3
Auxiliary switches 1 NO + 1 NC to be ordered separately,
see "Accessories".
* You can order this quantity or a multiple thereof.

7/6

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Front mounting
Number and version of the Rated data at
contacts
50 ... 60 Hz, 380 ... 440 V
Main contact Auxiliary
elements
contact
elements

DT

P/AC-3

P/AC-23A

Iu/
AC-21A

kW

kW

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches with rotary


operating mechanism/knob-operated mechanism
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
All versions with rotary operating mechanism
Exception: 3LD2 3 and 3LD2 4 with knob-operated mechanism
Including terminal cover for the infeed side
Front plate
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm 67 mm
- 3LD2 5 to 3LD2 8: 90 mm 90 mm
- 3LD2 3 to 3LD2 4: 96 mm 96 mm

Center-hole mounting 22.5 mm


3

3+N

--

--

3LD2 254-0TK53
3

1 NO +
1 NC

5.5

7.5

16

3LD2 054-0TK5@

1 unit

103

0.215

7.5

9.5

25

3LD2 154-0TK5@

1 unit

103

0.215

9.5

11.5

32

3LD2 254-0TK5@

1 unit

103

0.214

18.5

22

63

3LD2 555-0TK5@

1 unit

103

0.443

5.5

7.5

16

3LD2 054-1TL5@

1 unit

103

0.230

7.5

9.5

25

3LD2 154-1TL5@

1 unit

103

0.256

9.5

11.5

32

3LD2 254-1TL5@

1 unit

103

0.260

18.5

22

63

1 unit

103

0.443

3LD2 555-0TK5@
+1)
3LD9 250-0BA

1 unit

103

0.079

5.5

7.5

16

3LD2 054-1TP5@

1 unit

103

0.261

7.5

9.5

25

3LD2 154-1TP5@

1 unit

103

0.257

9.5

11.5

32

3LD2 254-0TK5@
+2)
3LD9 200-5B

1 unit

103

0.214

1 unit

103

0.046

18.5

22

63

1 unit

103

0.443

3LD2 555-0TK5@
+2)
3LD9 200-5B

1 unit

103

0.046

3+N

1 NO +
1 NC

5.5
7.5

7.5
9.5

16
25

A
C

3LD2 054-2EP5@
3LD2 154-2EP5@

1
1

1 unit
1 unit

103
103

0.276
0.304

9.5

11.5

32

3LD2 254-1TL5@
+2)
3LD9 200-5B

1 unit

103

0.260

1 unit

103

0.046

3LD2 555-0TK5@
+1)
3LD9 250-0BA
+2)
3LD9 200-5B

1 unit

103

0.443

1 unit

103

0.079

1 unit

103

0.046

}
18.5

22

63

A
}
}

Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

4. Contact element as N conductor to be ordered separately,


see "Accessories".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

>
1
3

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/7

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Front mounting
Number and version
of the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main contact Auxiliary


elements
contact
elements

P/AC-23A

Iu

kW

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


with knob-operated mechanism
Lockable in 0 position (can be modified to I position) with
max. 2 padlocks
Degree of protection at front side IP65
Including terminal cover for the infeed side
Front plate
- 48 mm 48 mm

Four-hole mounting
3

3+N

--

--

7.5

16

3LD2 022-0TK1@

1 unit

103

0.186

9.5

25

3LD2 122-0TK1@

1 unit

103

0.181

11.5

32

3LD2 222-0TK1@

1 unit

103

0.182

7.5

16

3LD2 022-1TL1@

1 unit

103

0.206

9.5

25

3LD2 122-1TL1@

1 unit

103

0.180

11.5

32

3LD2 222-0TK1@
+1)
3LD9 220-0B

1 unit

103

0.182

1 unit

103

0.039

3LD2 022-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.186

1 unit

103

0.046

3LD2 122-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.181

1 unit

103

0.046

3LD2 222-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.182

1 unit

103

0.046

3LD2 022-1TL1@
+2)
3LD9 200-5B

1 unit

103

0.206

1 unit

103

0.046

3LD2 122-1TL1@
+2)
3LD9 200-5B

1 unit

103

0.180

1 unit

103

0.046

3LD2 222-0TK1@
+1)
3LD9 220-0B
+2)
3LD9 200-5B

1 unit

103

0.182

1 unit

103

0.039

1 unit

103

0.046

}
3LD2 222-0TK11

1 NO + 1 NC 7.5

16

9.5

25

11.5

32

1 NO + 1 NC 7.5

16

9.5

25

11.5

32

}
}
}
3+N

}
}
}
}
Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

4. Contact element as N conductor to be ordered separately,


see "Accessories".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

>
1
3

* You can order this quantity or a multiple thereof.

7/8

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Front mounting
Number and version
of the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

P/AC-23A

Iu

kW

Auxiliary
contact
elements

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


with knob-operated mechanism
Lockable in 0 position (can be modified to I position)
with max. 2 padlocks
Degree of protection at front side IP65
Including terminal cover for the infeed side
Front plate: 48 mm 48 mm

Center-hole mounting 22.5 mm


3

3+N

--

--

7.5

16

3LD2 050-0TK1@

1 unit

103

0.197

9.5

25

3LD2 150-0TK1@

1 unit

103

0.191

11.5

32

3LD2 250-0TK1@

1 unit

103

0.192

7.5

16

3LD2 050-1TL1@

1 unit

103

0.215

9.5

25

3LD2 150-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.191

1 unit

103

0.046

11.5

32

3LD2 250-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.192

1 unit

103

0.046

3LD2 050-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.197

1 unit

103

0.046

3LD2 150-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.191

1 unit

103

0.046

3LD2 250-0TK1@
+2)
3LD9 200-5B

1 unit

103

0.192

1 unit

103

0.046

3LD2 050-1TL1@
+2)
3LD9 200-5B

1 unit

103

0.215

1 unit

103

0.046

3LD2 150-0TK1@
+1)
3LD9 220-0B
+2)
3LD9 200-5B

1 unit

103

0.191

1 unit

103

0.039

1 unit

103

0.046

3LD2 250-0TK1@
+1)
3LD9 220-0B
+2)
3LD9 200-5B

1 unit

103

0.192

1 unit

103

0.039

1 unit

103

0.046

}
}

3LD2 150-0TK13
3

1 NO +
1 NC

7.5

16

9.5

25

11.5

32

7.5

16

9.5

25

}
}
}

3+N

1 NO +
1 NC

}
}
}
11.5

32

A
}
}

Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

4. Contact element as N conductor to be ordered separately,


see "Accessories".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

>
1
3

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/9

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Front mounting
Number and version of Rated data at
the contacts
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

Auxiliary
contact
elements

DT

P/AC-3

P/AC-23A

Iu

kW

kW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


with rotary operating mechanism/
knob-operated mechanism (6-pole)
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
All versions with rotary operating mechanism
Exception: 3LD2 3 and 3LD2 4 with knob-operated mechanism
Including terminal cover for the infeed side
Front plate
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm 67 mm
- 3LD2 5: 90 mm 90 mm
- 3LD2 3 to 3LD2 4: 96 mm 96 mm

7
Four-hole mounting

3LD2 103-3VK53

--

1 NO +
1 NC

7.5

9.5

25

3LD2 103-3VK5@

1 unit

103

0.380

9.5

11.5

32

3LD2 203-3VK5@

1 unit

103

0.381

18.5

22.0

63

3LD2 504-3VK5@

1 unit

103

0.854

50

75

160

3LD2 305-3VK1@

1 unit

103

3.900

110

132

250

3LD2 405-3VK1@

1 unit

103

3.900

7.5

9.5

25

3LD2 103-4VP5@

1 unit

103

0.432

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

>
1

Actuator color
Black
Red/yellow (EMERGENCY-STOP)

Number and version of Rated data at


the contacts
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

Auxiliary
contact
elements

DT

P/AC-3

P/AC-23A

Iu

kW

kW

Order No.

kg

Changeover switches
with knob-operated mechanism
Black actuator
Knob-operated mechanism on 3LD2 3 and 3LD2 4 is lockable,
on all other versions it is non-lockable
Degree of protection at front side IP65

Four-hole mounting
3

--

3LD2 123-7UK01
3+N

7.5

9.5

25

3LD2 123-7UK01

1 unit

103

0.374

9.5

11.5

32

3LD2 223-7UK01

1 unit

103

0.378

18.5

22.0

63

3LD2 524-7UK01

1 unit

103

0.841

30.0

37.0

100

3LD2 724-7UK01

1 unit

103

1.061

50

75

160

3LD2 305-7UK01

1 unit

103

4.300

110

132

250

3LD2 405-7UK01

1 unit

103

4.400

50

75

160

3LD2 305-7UL01

1 unit

103

5.700

110

132

250

3LD2 405-7UL01

1 unit

103

5.700

3LD2 405-7UL01

* You can order this quantity or a multiple thereof.

7/10

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Floor mounting

Selection and ordering data


Number and version
of the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

P/AC-23A

Iu

kW

Auxiliary
contact
elements

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches with


door-coupling rotary operating mechanism
With shaft
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
Door-coupling rotary operating mechanism with integrated tolerance compensation (16 A to 125 A)
All versions with rotary operating mechanism

Exception: 3LD2 3 and 3LD2 4 with knob-operated


mechanism
Mounting using screws or snap-on mounting on 35 mm
standard mounting rail (16 A to 125 A)
Including terminal cover for the infeed side
Front plate
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm x 67 mm
- 3LD2 5 to 3LD2 8: 90 mm x 90 mm
- 3LD2 3 to 3LD2 4: 96 mm x 96 mm
Mounting dimensions
- 3LD2 0, 3LD2 1, 3LD2 2: 380 mm
- 3LD2 5 to 3LD2 8: 390 mm
- 3LD2 3 to 3LD2 4: 600 mm

Four-hole mounting
3

3+N
3LD2 213-0TK53

--

--

7.5

16

3LD2 013-0TK5@

1 unit

103

0.412

9.5

25

3LD2 113-0TK5@

1 unit

103

0.407

11.5

32

3LD2 213-0TK5@

1 unit

103

0.405

22

63

3LD2 514-0TK5@

1 unit

103

0.655

37

100

3LD2 714-0TK5@

1 unit

103

0.765

45

125

3LD2 814-0TK5@

1 unit

103

0.766

75

160

3LD2 318-0TK1@

1 unit

103

2.400

132

250

3LD2 418-0TK1@

1 unit

103

2.700

7.5

16

3LD2 013-1TL5@

1 unit

103

0.412

9.5

25

3LD2 113-1TL5@

1 unit

103

0.450

11.5

32

3LD2 213-1TL5@

1 unit

103

0.446

22

63

3LD2 514-1TL5@

1 unit

103

0.720

37

100

3LD2 714-0TK5@
+1)
3LD9 280-0C

1 unit

103

0.765

1 unit

103

0.102

45

125

1 unit

103

0.766

3LD2 814-0TK5@
+1)
3LD9 280-0C

1 unit

103

0.102

75

160

3LD2 318-1TL1@

1 unit

103

2.900

132

250

3LD2 418-1TL1@

1 unit

103

3.200

Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

>
1
3

4. Contact element as N conductor to be ordered separately,


see "Accessories".

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/11

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Floor mounting
Number and version
of the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

P/AC-23A

Iu

kW

7.5

16

9.5

25

Auxiliary
contact
elements

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Four-hole mounting (continued)


3

1 NO +
1 NC

}
}
}
}
}

11.5

32

22

63

37

100

45

125

75

160

132

250

7.5

16

9.5

25

}
}

3LD2 213-0TK53

}
}

}
3+N

1 NO +
1 NC

}
}
11.5

32

22

63

37

100

}
}
}
}
}
45

125

A
}
}

75

160

132

250

}
Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

4. Contact element as N conductor to be ordered separately,


see "Accessories".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

3LD2 013-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.412

1 unit

103

0.046

3LD2 113-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.407

1 unit

103

0.046

3LD2 213-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.405

1 unit

103

0.046

3LD2 514-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.655

1 unit

103

0.046

3LD2 714-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.765

1 unit

103

0.046

3LD2 814-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.766

1 unit

103

0.046

3LD2 318-0TK1@
+2)
3LD9 200-5C

1 unit

103

2.400

1 unit

103

0.046

3LD2 418-0TK1@
+2)
3LD9 200-5C

1 unit

103

2.700

1 unit

103

0.046

3LD2 013-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.412

1 unit

103

0.046

3LD2 113-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.450

1 unit

103

0.046

3LD2 213-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.446

1 unit

103

0.046

3LD2 514-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.720

1 unit

103

0.046

3LD2 714-0TK5@
+1)
3LD9 280-0C
+2)
3LD9 200-5C

1 unit

103

0.765

1 unit

103

0.102

1 unit

103

0.046

3LD2 814-0TK5@
+1)
3LD9 280-0C
+2)
3LD9 200-5C

1 unit

103

0.766

1 unit

103

0.102

1 unit

103

0.046

3LD2 318-1TL1@
+2)
3LD9 200-5C

1 unit

103

2.900

1 unit

103

0.046

3LD2 418-1TL1@
+2)
3LD9 200-5C

1 unit

103

3.200

1 unit

103

0.046

>
1
3

* You can order this quantity or a multiple thereof.

7/12

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Floor mounting
Number and version
of the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

P/AC-23A

Iu

kW

Auxiliary
contact
elements

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


with door-coupling rotary operating mechanism
With shaft
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
Door-coupling rotary operating mechanism with integrated tolerance compensation (16 A to 125 A)
All versions with rotary operating mechanism
Exception: 3LD2 3 and 3LD2 4 with knob-operated
mechanism

Mounting using screws or snap-on mounting on 35 mm


standard mounting rail (16 A to 125 A)
Including terminal cover for the infeed side
Front plate
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm x 67 mm
- 3LD2 5 to 3LD2 8: 90 mm x 90 mm
- 3LD2 3 to 3LD2 4: 96 mm x 96 mm
Mounting dimensions
- 3LD2 0, 3LD2 1, 3LD2 2: 380 mm
- 3LD2 5 to 3LD2 8: 390 mm
- 3LD2 3 to 3LD2 4: 600 mm

Center-hole mounting 22.5 mm


3

3+N

--

--

7.5

16

3LD2 044-0TK5@

1 unit

103

0.430

9.5

25

3LD2 144-0TK5@

1 unit

103

0.426

11.5

32

3LD2 244-0TK5@

1 unit

103

0.427

22

63

3LD2 545-0TK5@

1 unit

103

0.710

7.5

16

3LD2 044-1TL5@

1 unit

103

0.433

9.5

25

3LD2 144-1TL5@

1 unit

103

0.461

11.5

32

3LD2 244-1TL5@

1 unit

103

0.465

22

63

3LD2 545-0TK5@
+1)
3LD9 250-0CA

1 unit

103

0.710

1 unit

103

0.080

7.5

16

3LD2 044-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.430

1 unit

103

0.046

9.5

25

3LD2 144-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.426

1 unit

103

0.046

3LD2 244-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.427

1 unit

103

0.046

3LD2 545-0TK5@
+2)
3LD9 200-5C

1 unit

103

0.710

1 unit

103

0.046

3LD2 044-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.433

1 unit

103

0.046

3LD2 144-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.461

1 unit

103

0.046

3LD2 244-1TL5@
+2)
3LD9 200-5C

1 unit

103

0.465

1 unit

103

0.046

3LD2 545-0TK5@
+1)
3LD9 250-0CA
+2)
3LD9 200-5C

1 unit

103

0.710

1 unit

103

0.080

1 unit

103

0.046

3LD2 144-0TK53

}
3

1 NO +
1 NC

}
}
11.5

32

22

63

}
}
3+N

1 NO +
1 NC

7.5

16

9.5

25

11.5

32

22

63

}
}
}
}
}
Actuator color
Black
Red/yellow (EMERGENCY-STOP)

1)

4. Contact element as N conductor to be ordered separately,


see "Accessories".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

>
1
3

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/13

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Floor mounting
Number and version of
the contacts

Rated data at
50 ... 60 Hz, 380 V ... 440 V

Main
contact
elements

P/AC-3

P/AC-23A

Iu

kW

kW

Auxiliary
contact
elements

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches with


door-coupling rotary operating mechanism (6-pole)
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
Door-coupling rotary operating mechanism with integrated
tolerance compensation (for 3LD21)
All versions with rotary operating mechanism
Exception: 3LD2 3 and 3LD2 4 with door-coupling rotary
operating mechanism as selector switch
Mounting using screws or snap-on mounting on 35 mm
standard mounting rail

Including terminal cover for the infeed side


Front plate
- 3LD2 0, 3LD2 1, 3LD2 2: 67 mm 67 mm
- 3LD2 3, 3LD2 4: 96 mm 96 mm

Four-hole mounting
6

--

9.5

25

3LD2 113-3VK5@

1 unit

103

0.604

--

50

7.5

75

160

3LD2 318-3VK1@

1 unit

103

4.500

--

110

132

250

3LD2 418-3VK1@

1 unit

103

4.500

1 NO +
1 NC

25

3LD2 113-4VP5@

1 unit

103

0.645

9.5

9.5

3LD2 113-3VK51

>
1

Actuator color
Black
Red/yellow (EMERGENCY-STOP)

Number and version of Rated data at


the contacts
50 ... 60 Hz, 380 V ... 440 V

Main
contact
elements

Auxiliary
contact
elements

DT

P/AC-3

P/AC-23A

Iu

kW

kW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Changeover switches
with door-coupling rotary operating mechanism
Lockable in 0 position with up to 3 padlocks
Handle and cover black
Door-coupling rotary operating mechanisms as selector
switch
Degree of protection at front side IP65

Four-hole mounting
3

50

75

160

3LD2 318-7UK01

1 unit

103

5.000

110

132

250

3LD2 418-7UK01

1 unit

103

5.000

3+N

50

75

160

3LD2 318-7UL01

1 unit

103

6.400

3+N

110

132

250

3LD2 418-7UL01

1 unit

103

6.400

* You can order this quantity or a multiple thereof.

7/14

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Floor mounting
Number and version of
the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

P/AC-23A

Iu

kW

Auxiliary
contact
elements

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


with defeatable door-coupling rotary operating
mechanism
The SENTRON 3LD main and EMERGENCY-STOP switch
with defeatable door-coupling rotary operating mechanism enables you to conduct repairs, maintenance work
or tests on electrical plants and machines without having
to interrupt their operation. With the help of the defeatable door-coupling rotary operating mechanism, an electrician can bypass the interlock in ON position and open
the control cabinet door with the plant activated.

SENTRON 3LD main and EMERGENCY-STOP switches


with defeatable door-coupling rotary operating mechanism are approved according to UL 508.
With 300 mm switch shaft
Lockable in 0 position with up to 3 padlocks
Degree of protection at front side IP65
Door-coupling rotary operating mechanism with integrated tolerance compensation
Mounting using screws or snap-on mounting on 35 mm
standard mounting rail
Including terminal cover for the infeed side
Front plate 65 mm 65 mm

Four-hole mounting
3

3+N

--

--

7.5

16

3LD2 017-0TK1@

1 unit

103

0.412

11.5

32

3LD2 217-0TK1@

1 unit

103

0.412

22

63

3LD2 517-0TK1@

1 unit

103

0.412

7.5

16

3LD2 017-1TL1@

1 unit

103

0.412

11.5

32

3LD2 217-1TL1@

1 unit

103

0.412

22

63

3LD2 517-1TL1@

1 unit

103

0.412

3LD2 017-0TK..
Actuator color
Black
Red/yellow (EMERGENCY-STOP)

>
1
3

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/15

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Distribution board mounting

Selection and ordering data


Number and version of
the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

Main
contact
elements

P/AC-23A

Iu

kW

Auxiliary
contact
elements

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

ON/OFF and EMERGENCY-STOP switches


with masking plate and selector switch
With screw mounting
With snap-on mounting on 35 mm standard mounting rail
(16 to 125 A)
Lockable in 0 position with up to 2 (160 A and 250 A:
max. 3) padlocks
Degree of protection at front side IP44

Including terminal cover for the infeed and outgoing terminal (160 A and 250 A)
3

--

3LD2 530-0TK13

3+N

--

7.5

16

3LD2 030-0TK1@

1 unit

103

0.169

9.5

25

3LD2 130-0TK1@

1 unit

103

0.171

11.5

32

3LD2 230-0TK1@

1 unit

103

0.168

22

63

3LD2 530-0TK1@

1 unit

103

0.311

37

100

3LD2 730-0TK1@

1 unit

103

0.379

45

125

3LD2 830-0TK1@

1 unit

103

0.379

75

160

3LD2 330-0TK1@

1 unit

103

2.000

132

250

3LD2 430-0TK1@

1 unit

103

2.000

7.5

16

3LD2 030-1TL1@

1 unit

103

0.183

9.5

25

3LD2 130-0TK1@
+1)
3LD9 220-0C

1 unit

103

0.171

1 unit

103

0.039

11.5

32

3LD2 230-0TK1@
+1)
3LD9 220-0C

1 unit

103

0.168

1 unit

103

0.039

22

63

3LD2 530-0TK1@
+1)
3LD9 250-0CA

1 unit

103

0.311

1 unit

103

0.080

3LD2 730-0TK1@
+1)
3LD9 280-0C

1 unit

103

0.379

1 unit

103

0.102

3LD2 830-0TK1@
+1)
3LD9 280-0C

1 unit

103

0.379

1 unit

103

0.102

3LD2 330-0TK1@
+1)
3LD9 240-0C

1 unit

103

2.000

1 unit

103

0.500

3LD2 430-0TK1@
+1)
3LD9 240-0C

1 unit

103

2.000

1 unit

103

0.500

}
}
}

3LD2 330-0TK11
37

100

45

125

75

160

132

250

}
}
}
}
Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

>
1
3

4. contact element as N conductor to be ordered separately;


see "Accessories for floor mounting".

* You can order this quantity or a multiple thereof.

7/16

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Distribution board mounting
Number and version of
the contacts

Rated data at
50 ... 60 Hz, 380 ... 440 V

DT

Order No.

Main
contact
elements

Auxiliary
contact
elements

P/AC-23A

kW

1 NO +
1 NC

7.5

16

9.5

25

11.5

32

22

63

}
37

100

45

125

}
}
75

160

132

250

7.5

16

9.5

25

}
}
1 NO +
1 NC

PG

Weight
per PU
approx.

3LD2 030-0TK1@
+2)
3LD9 200-5C

1 unit

103

0.169

1 unit

103

0.046

3LD2 130-0TK1@
+2)
3LD9 200-5C

1 unit

103

0.171

1 unit

103

0.046

3LD2 230-0TK1@
+2)
3LD9 200-5C

1 unit

103

0.168

1 unit

103

0.046

3LD2 530-0TK1@
+2)
3LD9 200-5C

1 unit

103

0.311

1 unit

103

0.046

3LD2 730-0TK1@
+2)
3LD9 200-5C

1 unit

103

0.379

1 unit

103

0.046

3LD2 830-0TK1@
+2)
3LD9 200-5C

1 unit

103

0.379

1 unit

103

0.046

3LD2 330-0TK1@
+2)
3LD9 200-5C

1 unit

103

2.000

1 unit

103

0.046

3LD2 430-0TK1@
+2)
3LD9 200-5C

1 unit

103

2.000

1 unit

103

0.046

3LD2 030-1TL1@
+2)
3LD9 200-5C

1 unit

103

0.183

1 unit

103

0.046

3LD2 130-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 220-0C

1 unit

103

0.171

1 unit

103

0.046

1 unit

103

0.039

3LD2 230-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 220-0C

1 unit

103

0.168

1 unit

103

0.046

1 unit

103

0.039

3LD2 530-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 250-0CA

1 unit

103

0.311

1 unit

103

0.046

1 unit

103

0.080

3LD2 730-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 280-0C

1 unit

103

0.379

1 unit

103

0.046

1 unit

103

0.102

3LD2 830-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 280-0C

1 unit

103

0.379

1 unit

103

0.046

1 unit

103

0.102

3LD2 330-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 240-0C

1 unit

103

2.000

1 unit

103

0.046

1 unit

103

0.500

3LD2 430-0TK1@
+2)
3LD9 200-5C
+1)
3LD9 240-0C

1 unit

103

2.000

1 unit

103

0.046

1 unit

103

0.500

kg

3+N

PS*/
P. unit

Iu

}
3LD2 530-0TK11

Price
PU
per PU (UNIT,
SET,
M)

}
}
}
11.5

32

A
}
}

22

63

A
}
}

37

100

A
}
}

45

125

A
}
}

75

160

A
}
}

132

250

A
}
}

Actuator color
Black
Red/yellow (EMERGENCY-STOP)
1)

4. contact element as N conductor to be ordered separately;


see "Accessories for floor mounting".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

>
1
3

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/17

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Molded-plastic enclosures

Selection and ordering data


Number and version of Base
Rated data at
the contacts
terminal 50 ... 60 Hz,
380 ... 440 V
Main
contact
elements

Auxiliary
contact
elements

DT

P/AC-23A

Iu

kW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


With N- and/or PE-/ground base terminals
Lockable in 0 position with
up to 3 padlocks
Degree of protection IP65
Rotary operating mechanisms with center-hole mounting
For floor-mounted auxiliary switches

Metric screwed glands


3

3+N

--

--

3LD2 164-0TB53

PE + N 7.5

16

3LD2 064-0TB5@

1 unit

103

0.463

PE + N 9.5

25

3LD2 164-0TB5@

1 unit

103

0.463

PE + N 11.5

32

3LD2 264-0TB5@

1 unit

103

0.465

PE + N 22

63

3LD2 565-0TB5@

1 unit

103

0.906

PE + N 37

100

3LD2 766-0TB5@

1 unit

103

1.890

PE + N 45

125

3LD2 866-0TB5@

1 unit

103

1.890

PE

7.5

16

3LD2 064-1TC5@

1 unit

103

0.453

PE

9.5

25

3LD2 164-1TC5@

1 unit

103

0.487

PE

11.5

32

3LD2 264-1TC5@

1 unit

103

0.500

PE

22

63

3LD2 565-1TC5@

1 unit

103

0.960

PE + N 37

100

3LD2 766-0TB5@
+1)
3LD9 280-0C

1 unit

103

1.890

1 unit

103

0.102

PE + N 45

125

1 unit

103

1.890

3LD2 866-0TB5@
+1)
3LD9 280-0C

1 unit

103

0.102

3+N

1 NO +
1 NC

1 NO +
1 NC

7.5

16

3LD2 064-1GP5@

1 unit

103

0.507

9.5

25

3LD2 164-1GP5@

1 unit

103

0.501

11.5

32

3LD2 264-1GP5@

1 unit

103

0.488

22

63

3LD2 565-1GP5@

1 unit

103

0.935

37

100

3LD2 766-1GP5@

1 unit

103

1.838

45

125

3LD2 866-1GP5@

1 unit

103

1.843

PE

7.5

16

3LD2 064-1TC5@
+2)
3LD9 200-5C

1 unit

103

0.453

1 unit

103

0.046

PE

9.5

25

3LD2 164-1TC5@
+2)
3LD9 200-5C

1 unit

103

0.487

1 unit

103

0.046

PE

11.5

32

3LD2 264-1TC5@
+2)
3LD9 200-5C

1 unit

103

0.500

1 unit

103

0.046

PE

22

63

3LD2 565-1TC5@
+2)
3LD9 200-5C

1 unit

103

0.960

1 unit

103

0.046

37

100

3LD2 766-1GP5@
+1)
3LD9 280-0C

1 unit

103

1.838

1 unit

103

0.102

45

125

3LD2 866-1GP5@
+1)
3LD9 280-0C

1 unit

103

1.843

1 unit

103

0.102

}
}
}
}
}
}
Actuator color
Black

Red/yellow (EMERGENCY-STOP)
1)

4. contact element as N conductor to be ordered separately;


see "Accessories for floor mounting".

2)

Auxiliary switches 1 NO + 1 NC to be ordered separately,


see "Accessories".

>
1
3

* You can order this quantity or a multiple thereof.

7/18

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Molded-plastic enclosures
Number and version Base
Rated data at
of the contacts
terminal 50 ... 60 Hz,
380 ... 440 V
Main
Auxiliary
contact
contact
elements elements

DT

P/AC-3

P/AC-23A Iu

kW

kW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Main and EMERGENCY-STOP switches


with rotary operating mechanism (6-pole)
With N- and/or PE-/ground base terminals
Degree of protection IP65
Metric screwed glands
6

--

1 NO +
1 NC

PE + N 7.5

9.5

25

3LD2 165-3VB5@

1 unit

103

0.880

PE + N 9.5

11.5

32

3LD2 265-3VB5@

1 unit

103

0.878

PE + N 18.5

22.0

63

3LD2 566-3VB5@

1 unit

103

2.105

7.5

9.5

25

3LD2 165-4VD5@

1 unit

103

0.914

9.5

11.5

32

3LD2 265-4VD5@

1 unit

103

0.910

22.0

63

3LD2 566-4VD5@

1 unit

103

2.084

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

PE + N 18.5

3LD2 165-3VB53

>
1

Actuator color
Black
Red/yellow (EMERGENCY-STOP)

Number and version Base


Rated data at
of the contacts
terminal 50 ... 60 Hz,
380 ... 440 V
Main
Auxiliary
contact
contact
elements elements

DT

P/AC-3

P/AC-23A Iu

kW

kW

Order No.

kg

Changeover switches
with knob-operated mechanism
With N- and/or PE-/ground base terminals
Black actuator
Lockable in 0 position with up to 3 padlocks (25 A and 32 A)
Metric screwed glands
Degree of protection IP65
3

--

PE + N 7.5

9.5

25

3LD2 165-7UB01

1 unit

103

0.888

PE + N 9.5

11.5

32

3LD2 265-7UB01

1 unit

103

0.888

PE + N 18.5

22.0

63

3LD2 566-7UB01

1 unit

103

2.105

PE + N 30.0

37.0

100

3LD2 766-7UB01

1 unit

103

2.335

3LD2 165-7UB01

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/19

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
DC applications

Selection and ordering data


Mains voltage

Rated current Ie
at 800 V DC

Max.

DC-21A

DC-22A

V DC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Solar plant isolators


in molded-plastic enclosure
Molded-plastic enclosure IP65
Metric screwed glands
(W x H x D) 146 mm x 199 mm x 136 mm
Conductor cross-sections:
- Solid and stranded 1.5 16 mm2
- Finely stranded with end sleeve max. 10 mm2
Lockable

800

32

16

3LD2 265-8VQ5@-0AF6

1 unit

103

0.878

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

3LD2 265-8VQ5.-0AF6

>
1

Actuator color
Black
Red/yellow (EMERGENCY-STOP)

Mains voltage

Rated current Ie
at 800 V DC

Max.

DC-21A

DC-22A

V DC

DT

Order No.

kg

Solar plant isolators


for distribution board mounting
Conductor cross-sections:
- Solid and stranded 1.5 16 mm2
- Finely stranded with end sleeve up to 10 mm2
Actuator color: Black
800

32

16

3LD2 230-8VQ11-0AF6

1 unit

103

0.878

3LD2 265-8VQ11-0AF6

* You can order this quantity or a multiple thereof.

7/20

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Accessories

Selection and ordering data


Version

DT 3LD2 0

Order No.

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.

kg

For front mounting


}

3LD9 200-2B

1 unit

103

0.030

3LD9 200-5B

1 unit

103

0.046

3LD9 200-5BF

1 unit

103

0.028

3LD9 200-2C

1 unit

103

0.032

1 NO + 1 NC

3LD9 200-5C

1 unit

103

0.046

2 NO

3LD9 200-6C

1 unit

103

0.046

3LD9 200-5CF

1 unit

103

0.028

A
A

3LD9 224-1B

1 unit

103

0.072

3LD9 224-3B

1 unit

103

0.075

- Black

3LD9 224-1D

1 unit

103

0.080

- Red/Yellow

3LD9 224-3D

1 unit

103

0.081

3LD9 256-0A

5 units

103

0.027

Length 300 mm

3LD9 205-0C

5 units

103

0.476

Length 600 mm

3LD9 205-2C

5 units

103

0.476

With English/German inscription


(MAIN SWITCH/HAUPTSCHALTER)

3LD9 286-1A

1 10 units

103

0.005

Without inscription

3LD9 286-4A

1 10 units

103

0.054

1-pole

3LD9 201-2A

100

4 units

103

0.200

3-/4-pole

3LD9 201-1A

4 units

103

0.007

N or PE terminals
Through-type

3LD9 200-2B

3LD9 200-5B

Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off
1 NO + 1 NC
For mounting on the left and/or right, lagging switch-on,
with gold-plate contacts for SIMATIC request, leading
switch-off
1 NO + 1 NC

For floor mounting, distribution board mounting or molded-plastic


enclosures
N or PE terminals
Through-type

3LD9 200-2C
Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off

3LD9 200-5C (left)


3LD9 200-6C (right)

For mounting on the left and/or right, lagging switch-on,


with gold-plate contacts for SIMATIC request, leading
switch-off
1 NO + 1 NC

For front and floor mounting


Rotary operating mechanisms
Lockable in 0 position with up to 3 padlocks
For four-hole mounting, including seal
- Black
- Red/Yellow
3LD9 224-1B

For center-hole mounting, including seal and nut

3LD9 224-3D
Assembly tools
For center-hole mounting with nut

3LD9 256-0A
Switching shafts 6 x 6 mm

Inscription labels

3LD9 286-1A

Terminal covers as additional touch protection


(also for distribution board mounting)
Can be snapped on at top and bottom
3LD9 201-2A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/21

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Accessories
Version

DT 3LD2 1 and 3LD2 2

Order No.

PU
(UNIT,
SET,
M)
Price
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For front mounting


}

3LD9 220-0B

1 unit

103

0.039

3LD9 220-2B

1 unit

103

0.036

3LD9 200-5B

1 unit

103

0.046

3LD9 200-5BF

1 unit

103

0.028

3LD9 220-0C

1 unit

103

0.039

3LD9 220-2C

1 unit

103

0.037

}
}

3LD9 200-5C
3LD9 200-6C

1
1

1 unit
1 unit

103
103

0.046
0.046

3LD9 200-5CF

1 unit

103

0.028

- Black

3LD9 224-1B

1 unit

103

0.072

- Red/Yellow

3LD9 224-3B

1 unit

103

0.075

- Black

3LD9 224-1D

1 unit

103

0.080

- Red/Yellow

3LD9 224-3D

1 unit

103

0.081

3LD9 256-0A

5 units

103

0.027

Length 300 mm

3LD9 205-0C

5 units

103

0.476

Length 600 mm

3LD9 205-2C

5 units

103

0.476

With English/German inscription


(MAIN SWITCH/HAUPTSCHALTER)

3LD9 286-1A

1 10 units

103

0.005

Without inscription

3LD9 286-4A

1 10 units

103

0.054

1-pole

3LD9 221-2A

100

4 units

103

0.100

3-pole

3LD9 221-0A

4 units

103

0.007

4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type

3LD9 220-0B (left)


3LD9 220-2B (right)

Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off
1 NO + 1 NC
For mounting on the left and/or right, lagging switch-on,
leading switch-off, with gold-plate contacts for SIMATIC
request
1 NO + 1 NC

3LD9 200-5B

For floor mounting, distribution board mounting or molded-plastic


enclosures
4. contact (N conductor)
Leading switch-on, lagging switch-off

3LD9 220-0C
N or PE terminals
Through-type

3LD9 200-5C (left)


3LD9 200-6C (right)

Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off
1 NO + 1 NC
2 NO
For mounting on the left and/or right, lagging switch-on,
leading switch-off, with gold-plate contacts for SIMATIC
request
1 NO + 1 NC

For front and floor mounting


Rotary operating mechanisms
Lockable in 0 position with up to 3 padlocks
For four-hole mounting

3LD9 224-1B

For center-hole mounting, including seal and nut

3LD9 224-3D
Assembly tools
For center-hole mounting with nut

3LD9 256-0A
Switching shafts 6 x 6 mm

Inscription labels

3LD9 286-1A

Terminal covers as additional touch protection


(also for distribution board mounting)
Can be snapped on at top and bottom
3LD9 221-2A (left)
3LD9 221-0A (right)

* You can order this quantity or a multiple thereof.

7/22

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Accessories
Version

DT 3LD2 3 and 3LD2 4

Order No.

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.

kg

For front mounting


}

3LD9 240-0B

1 unit

103

0.500

3LD9 240-2B

1 unit

103

0.450

3LD9 200-5B

1 unit

103

0.046

3LD9 200-5BF

1 unit

103

0.028

3LD9 242-4F

5 units

103

0.159

3LD9 240-0C

1 unit

103

0.500

3LD9 240-2C

1 unit

103

0.450

1 NO + 1 NC

3LD9 200-5C

1 unit

103

0.046

2 NO

3LD9 200-6C

1 unit

103

0.046

3LD9 200-5CF

1 unit

103

0.028

- Black

3LD9 243-1B

1 unit

103

0.154

- Red/Yellow

3LD9 243-3B

1 unit

103

0.154

Length 300 mm

3LD9 245-0C

5 units

103

0.476

Length 600 mm

3LD9 245-2C

5 units

103

0.476

With English/German inscription


(MAIN SWITCH/HAUPTSCHALTER)

3LD9 286-1A

1 10 units

103

0.005

Without inscription

3LD9 286-4A

1 10 units

103

0.054

3LD9 241-2A

103

0.010

4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type
3LD9 240-0B (left)
3LD9 240-2B (right)
Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off
1 NO + 1 NC

3LD9 200-5B

For mounting on the left and/or right, lagging switch-on,


leading switch-off, with gold-plate contacts for SIMATIC
request
1 NO + 1 NC

For floor and distribution board mounting


Coupling piece
no ON-lock

3LD9 242-4F
4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type
3LD9 240-0C (left)
3LD9 240-2C (right)
Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off

3LD9 200-5C (left)


3LD9 200-6C (right)

For mounting on the left and/or right, lagging switch-on,


leading switch-off, with gold-plate contacts for SIMATIC
request
1 NO + 1 NC

For front and floor mounting


Knob-operated mechanism
Lockable in 0 position with up to 3 padlocks
For four-hole mounting, including seal
3LD9 243-1B

Switching shafts 8 x 8 mm

Inscription labels

3LD9 286-1A

Terminal covers as additional touch protection


(also for distribution board mounting)
Can be snapped on at top and bottom
1-pole

4 units

3LD9 241-2A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/23

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Accessories
Version

DT

3LD2 5

Order No.

PU
(UNIT,
SET,
M)
Price
per PU

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For front mounting


}

3LD9 250-0BA

1 unit

103

0.079

3LD9 250-2BA

1 unit

103

0.072

3LD9 200-5B

1 unit

103

0.046

3LD9 200-5BF

1 unit

103

0.028

3LD9 250-0CA

1 unit

103

0.080

3LD9 250-2CA

1 unit

103

0.073

}
}

3LD9 200-5C
3LD9 200-6C

1
1

1 unit
1 unit

103
103

0.046
0.046

3LD9 200-5CF

1 unit

103

0.028

- Black

3LD9 284-1B

1 unit

103

0.154

- Red/Yellow

3LD9 284-3B

1 unit

103

0.152

- Black

3LD9 284-1D

1 unit

103

0.155

- Red/Yellow

3LD9 284-3D

1 unit

103

0.155

3LD9 256-0A

5 units

103

0.027

Length 300 mm

3LD9 205-0C

5 units

103

0.476

Length 600 mm

3LD9 205-2C

5 units

103

0.476

With English/German inscription


(MAIN SWITCH/HAUPTSCHALTER)

3LD9 286-1A

1 10 units

103

0.005

Without inscription

3LD9 286-4A

1 10 units

103

0.054

1-pole

3LD9 251-2A

100

4 units

103

0.100

3-pole

3LD9 251-0A

4 units

103

0.009

4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type
3LD9 250-0BA (left)
3LD9 250-2BA (right)
Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off

1 NO + 1 NC
For mounting on the left and/or right, lagging switch-on,
leading switch-off, with gold-plate contacts for SIMATIC
request

3LD9 200-5B

1 NO + 1 NC

For floor mounting, distribution board mounting or molded-plastic


enclosures
4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type
3LD9 250-0CA (left)
3LD9 250-2CA (right)

3LD9 200-5C (left)


3LD9 200-6C (right)

Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off
1 NO + 1 NC
2 NO
For mounting on the left and/or right, lagging switch-on,
leading switch-off, with gold-plate contacts for SIMATIC
request
1 NO + 1 NC

For front and floor mounting


Rotary operating mechanisms
Lockable in 0 position with up to 3 padlocks
For four-hole mounting, including seal

3LD9 284-1B

For center-hole mounting, including seal and nut

3LD9 284-3D
Assembly tools
For center-hole mounting with nut

3LD9 256-0A
Switching shafts 6 x 6 mm

Inscription labels

3LD9 286-1A

Terminal covers as additional touch protection


(also for distribution board mounting)
Can be snapped on at top and bottom
3LD9 251-2A (left)
3LD9 251-0A (right)

* You can order this quantity or a multiple thereof.

7/24

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3LD Main and EMERGENCY-STOP Switches up to 250 A
Accessories
Version

DT

PU
(UNIT,
SET,
M)

3LD2 7 and 3LD2 8

Order No.

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.

kg

For front mounting


}

3LD9 280-0B

1 unit

103

0.101

3LD9 280-2B

1 unit

103

0.092

3LD9 200-5B

1 unit

103

0.046

3LD9 200-5BF

1 unit

103

0.028

3LD9 280-0C

1 unit

103

0.102

3LD9 280-2C

1 unit

103

0.093

1 NO + 1 NC

3LD9 200-5C

1 unit

103

0.046

2 NO

3LD9 200-6C

1 unit

103

0.046

3LD9 200-5CF

1 unit

103

0.028

Black

3LD9 284-1B

1 unit

103

0.154

Red/Yellow

3LD9 284-3B

1 unit

103

0.152

Length 300 mm

3LD9 205-0C

5 units

103

0.476

Length 600 mm

3LD9 205-2C

5 units

103

0.476

With English/German inscription


(MAIN SWITCH/HAUPTSCHALTER)

3LD9 286-1A

1 10 units

103

0.005

Without inscription

3LD9 286-4A

1 10 units

103

0.054

3LD9 281-2A

103

0.007

4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type
3LD9 280-0B (left)
3LD9 280-2B (right)
Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off
1 NO + 1 NC
3LD9 200-5B

For mounting on the left and/or right, lagging switch-on,


leading switch-off, with gold-plate contacts for SIMATIC request
1 NO + 1 NC

For floor mounting, distribution board mounting or molded-plastic


enclosures
4. contact (N conductor)
Leading switch-on, lagging switch-off
N or PE terminals
Through-type
3LD9 280-0C (left)
3LD9 280-2C (right)
Auxiliary switches
For mounting on the left and/or right, lagging switch-on,
leading switch-off

3LD9 200-5C (left)


3LD9 200-6C (right)

For mounting on the left and/or right, lagging switch-on,


leading switch-off, with gold-plate contacts for SIMATIC request
1 NO + 1 NC

For front and floor mounting


Rotary operating mechanisms for four-hole mounting
Lockable in 0 position with up to 3 padlocks,
including seal

3LD9 284-1B

Switching shafts 6 x 6 mm

Inscription labels

3LD9 286-1A

Terminal covers as additional touch protection (also for


distribution board mounting)
Can be snapped on at top and bottom
1-pole (1 pack = 4 units)

4 units

3LD9 281-2A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/25

Siemens AG 2011

Switch Disconnectors
5TE1 Switch Disconnectors up to 200 A
Introduction

Overview

Benefits

The 5TE1 switch disconnectors are available from 100 A to


200 A in 3 and 4-pole versions and can be used as main
switches, repair switches, outgoing feeder switches and emergency system interrupters.
The series corresponds to the requirements of IEC/EN 60947-3
and its key features are its compact and robust design, high
short-circuit strength, high DC switching capacity and comprehensive accessories.

Transparent enclosures ensure that the contact position is


always visible
Contacts with double breaks ensure reliable insulation characteristics
Can be locked in the OFF position to allow for maintenance
work.
With a red knob and yellow cap, it can also be used as an
emergency system interrupter.

Its small footprint means it is easy to install in all types of enclosures, distribution boards and control cabinets.
The devices are approved to UL 508 and KEMA certified.

Technical specifications

5TE1 .1

5TE1 .2

5TE1 .3

5TE1 .4

IEC/EN 60947-3, UL 508


UL 508 for the following types: 5TE1 320, 5TE1 330,
5TE1 340, 5TE1 420, 5TE1 430 and 5TE1 440.
UL File No. E302554

Standards
Approvals

Rated operational current Ie


With utilization category AC-21A

Per conducting path

At Ue=

400 V
415 V
500 V
690 V

A
A
A
A

100
100
100
100

125
125
125
125

160
160
160
160

200
200
200
200

Rated operational current Ie


With utilization category AC-22A

Per conducting path

At Ue=

400 V
415 V
500 V
690 V

A
A
A
A

100
100
100
63

125
125
100
63

160
160
160
160

200
200
200
200

Rated operational current Ie


With utilization category AC-23A

Per conducting path

At Ue=

400 V
415 V
500 V
690 V

A
A
A
A

80
80
50
40

125
125
125
63

160
160
125
80

Rated operational current Ie


With utilization category DC-23A

2 poles in series
2 poles in series
4 poles in series

110 V
220 V
220 V

A
A
A

100
-100

160
100
160

Rated operational voltage Ue

V AC

Acc. to UL: 480, acc. to IEC: 690

Rated insulation voltage Ui

V AC

690

Rated impulse withstand voltage Uimp

2000 m

kV

Impulse test voltage

At sea level

kV

12.3

kW
kW
kW
kW

44
46
35
36

At Ue=

Max. rated operational power


With utilization category AC-23A

400 V
415 V
500 V
690 V

88
92
86
76

Rated thermal current Ith

At 40 C, 50 C and 60 C

100

160

200

Rated making capacity

At 415 V AC-23A

1875

3200

4000

Rated breaking capacity

At 415 V AC-23A

1000

1920

2400

Rated ultimate short-circuit breaking capacity Icm

Per conducting path

400 V
415 V
500 V
690 V

kA
kA
kA
kA

10
10
6.7
6.7

Rated short-time withstand current Icw


(peak value)

Per conducting path

0.25 s
1s

kA
kA

5
2.5

400 V
415 V
500 V
690 V

kA
kA
kA
kA

50
50
50
33

33

20

18

kVar

50

60

77

97

4.5

6.5

10

At Ue=

Rated conditional short-circuit current


With back-up protection with back-up fuse
With identical rated current
Capacitive load

At Ue=

At 400 V

VA

2.9

Frequency

Hz

50/60

Conductor cross-sections
Solid and stranded
AWG cables
Copper busbars

mm2
AWG
mm2

6 ... 50
10 ... 1/0
--

Per pole

Endurance

Electrical
Mechanical

According to UL 508
UL 508 General Use 480 V
UL 508 Manual motor controller 230 V
UL 508 Manual motor controller 480 V
UL 508 Short-circuit at 480 V

In
FLA (Full load amperes)
Rating
Rating
With Class H or K5 fuses
With J fuses

7/26

Siemens LV 10.1 2011

6
3

2/3/4

Number of poles
Rated power dissipation Pv

125

69
72
86
60

-8
max. 20 6

Switching 1500
cycles 20000
A
A
hp
hp
kA
kA

-------

1000
10000
80
28
10
20
10
50

100
34
25
15

125
40
30
15

Siemens AG 2011

Switch Disconnectors
5TE1 Switch Disconnectors up to 200 A
General data

Selection and ordering data


Version

Ie

Ue

Width DT

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Switch disconnectors, lockable,


with gray knob and transparent enclosure,
mounting depth 92mm
2 NO
100
125

690

160
200

B
B

5TE1 210
5TE1 220

1
1

1 unit
1 unit

027
027

0.485
0.492

B
B

5TE1 230
5TE1 240

1
1

1 unit
1 unit

027
027

0.646
0.655

B
B

5TE1 310
5TE1 320

1
1

1 unit
1 unit

027
027

0.533
0.541

B
B

5TE1 330
5TE1 340

1
1

1 unit
1 unit

027
027

0.694
0.697

B
B

5TE1 410
5TE1 420

1
1

1 unit
1 unit

027
027

0.602
0.591

B
B

5TE1 430
5TE1 440

1
1

1 unit
1 unit

027
027

0.774
0.794

B
B

5TE1 610
5TE1 620

1
1

1 unit
1 unit

027
027

0.592
0.606

B
B

5TE1 630
5TE1 640

1
1

1 unit
1 unit

027
027

0.791
0.789

3 NO
100
125

690

160
200
4 NO
100
125

690

160
200
3 NO with N-conductor through-type terminal
100
125

690

160
200

Switch disconnectors with red knob and yellow cap,


can be used as emergency mains switching off device
acc. to IEC 60204-1, EN 60204-1 if switch is easily
accessible, mounting depth 92 mm
3 NO
100
125

690

160
200

B
B

5TE1 315
5TE1 325

1
1

1 unit
1 unit

027
027

0.545
0.550

B
B

5TE1 335
5TE1 345

1
1

1 unit
1 unit

027
027

0.693
0.722

B
B

5TE1 415
5TE1 425

1
1

1 unit
1 unit

027
027

0.596
0.609

B
B

5TE1 435
5TE1 445

1
1

1 unit
1 unit

027
027

0.803
0.806

4 NO
100
125
160
200

690

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/27

Siemens AG 2011

Switch Disconnectors
5TE1 Switch Disconnectors up to 200 A
General data

Accessories
Version

Ie

Ue

A AC

V AC

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Terminal covers
Sealable
For 100 A and 125 A load disconnect switches

5TE9 000

1 unit

027

0.043

For 160 A and 200 A load disconnect switches

5TE9 001

1 unit

027

0.037

1 set = 3 units

5TE9 003

1 set

027

0.245

1 set = 4 units

5TE9 004

1 set

027

0.323

Cage Clamp terminals

For 160 A und 200 A load disconnect switches,


14.5 mm terminal diameter for 35 mm2 cables,
hexagonal socket head screw 5 mm

Auxiliary switches
Can be mounted optionally left or right or both
sides (2 units);
minimum contact load 24 V, 50 mA
1 CO

230

5TE9 005

1 unit

027

0.042

2 CO

230

5TE9 006

1 unit

027

0.048

5TE9 014

1 unit

027

0.017

5TE9 015

1 set

027

0.078

B
B

5TE9 010
5TE9 011

1
1

1 unit
1 unit

027
027

0.177
0.234

B
B

5TE9 012
5TE9 013

1
1

1 unit
1 unit

027
027

0.175
0.234

Locking units
For up to three padlocks with max.  8 mm

Conversion kits, 4-pole, for 100 A and 125 A for the


connection of busbars or cables with cable lugs
For busbars max 15 mm wide
including terminal cover

Rotary actuators with extension axes for mounting


on hinged doors or enclosure lids, lockable, IP65
Black knob
Axis length 200 mm
Axis length 400 mm
Red knob
Axis length 200 mm
Axis length 400 mm

* You can order this quantity or a multiple thereof.

7/28

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
5TE1 Switch Disconnectors up to 200 A
General data

Dimensional drawings
5TE1 switch disconnectors, 100 A and 125 A

5TE9 auxiliary switches


73

9
90

5TE1 210
5TE1 220

5TE1 310
5TE1 315
5TE1 320
5TE1 325

5TE1 410
5TE1 415
5TE1 420
5TE1 425

42

92,5

5TE1 610
5TE1 620

5TE9 005
5TE9 006

5TE9 014 locking units


1x 2x 3x
max. 8 mm

5,5

73

90

45

13

ON
OFF

I2_07110a

80
70

44

I2_07112a

35

35

73

5TE1 switch disconnectors, 160 A and 200 A


35

45

90
44

I2_07109a

I2_07111c

45

90
75

44

70
144

5TE1 230
5TE1 240

5TE1 330
5TE1 335
5TE1 340
5TE1 345

5TE1 430
5TE1 435
5TE1 440
5TE1 445

92,5

5TE1 630
5TE1 640

5TE9 rotary actuators with extension axis

19 H 165/365

65
53,5

73
79

19 H 165/365

H+35 L H+100
2,5

SW16

H-7

SW16

H-7

65
53,5

H+35 L H+100

I2_07205b

2,5

73
79

0 37,5

6
32
I2_07206b

With switch disconnectors 100 A and 125 A


5TE9 010, 5TE9 011,
5TE9 012, 5TE9 013
It is possible to open the door in a disconnected state.

With switch disconnectors 160 A and 200 A


5TE9 010, 5TE9 011,
5TE9 012, 5TE9 013
It is possible to open the door in a disconnected state.

Siemens LV 10.1 2011

7/29

Siemens AG 2011

Switch Disconnectors
5TE1 Switch Disconnectors up to 200 A
General data

Schematics
Diagram

5TE9 auxiliary switches

1 3

1 3 5

1 3 5 7

1 2

2 4

2 4 6

2 4 6 8

5TE1 210
5TE1 220
5TE1 230
5TE1 240

5TE1 310
5TE1 320
5TE1 330
5TE1 340

2 4 6

2 4 6

5TE1 610
5TE1 620
5TE1 630
5TE1 640

5TE1 315
5TE1 325
5TE1 335
5TE1 345

5TE9 005

L1

L2

5TE9 006

1 3 5 7

1 3 5

1 3 5 N

5TE1 410
5TE1 420
5TE1 430
5TE1 440

1 2 3 4

2 4 6 8

5TE1 415
5TE1 425
5TE1 435
5TE1 445

More information
Connection of 5TE1 3 and 5TE1 4 switches, 160 and 200 A
10-12

I2_08070a

SW 5
SW 13

max. 12 Nm

10-12
8,5

max. 6
5TE9 003
5TE9 004
SW 5

7/30

20 max.
max. 14

Siemens LV 10.1 2011

Design
From 160 A: supplied with one terminal cover
160 A and 200 A: version for connection with cable lug
Screw fixing on base plate
Installation on standard mounting rail to EN 60715, which is
raised at least 5 mm from the base plate.

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Introduction

Overview

NSE0_01931b

7
4

1
2
3
4
5
6

Auxiliary switch (3SB for 3KA; 3KX for 3KE)


IP20 terminal cover (Operator side)
3K switch disconnector
Arcing contacts (only for 3KE)
Extension shaft
8UC7 door-coupling rotary operating mechanism in standard version
(ti-grey) or EMERGENCY-STOP version (red/yellow).
7 8UC9 knob for fixed mounting in standard version (black) or
EMERGENCY-STOP version (red/yellow).

All components from the switch to the actuator are provided with
non-interchangeability features.

For the 3KA switch disconnectors, complete kits for standard


and EMERGENCY-STOP application are available for installation
in the side and rear panels of control cabinets.

An operating linkage permits simultaneous switching of two 3KE


switch disconnectors with identical or different rated operational
currents.

A changeover operating mechanism is available for the use of


2 switch disconnectors in the 3KE series as load changeover
switches.

Identical accessories for 3KA switch disconnectors and for 3KL


and 3KM switch disconnectors with fuses simplify stock keeping.

Application
3KA and 3KE switch disconnectors are used as main,
EMERGENCY-STOP, maintenance and transfer switches in distribution boards for residential and non-residential buildings as
well as industrial switchboards. As three and four-pole versions,
they ensure activation and deactivation of the specified rated
current under load. At the same time, they constitute a safety isolating function and isolating distance in all low-voltage circuits.

All 3K switch disconnectors are climate-proof and meet the


requirements of IEC 60947-1 and IEC 60947-3. Switch disconnectors in the type-tested 8HP molded-plastic distribution board
enclosure (degree of protection IP65) are available for use as
safety switches.
Additional data, see catalog LV 10.2, chapter 18
"Distribution Boards" and chapter 19 "Terminal Blocks".

Siemens LV 10.1 2011

7/31

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Introduction

Technical specifications
Standards

IEC 60947-1, IEC 60947-3


3KA50

3KA51

3KA521)

3KA531)

3KA551)

3KA571)

3KA581)

63

80

125

160

250

400

6303)

Type
Rated uninterrupted current Iu

63

80

125

160

250

400

6303)

Rated insulation voltage Ui

690

690

1000

1000

1000

1000

1000

Rated impulse withstand voltage Uimp

kV

50/60 Hz AC

690

DC

V
V
V

440 (3 conducting paths series-connected)


220 (2 conducting paths series-connected)
110 (1 conducting path)

Rated short-circuit making capacity Icm


with upstream fuses4)
At 50/60 Hz 690 V AC, peak value

kA

220

220

220

220

176

176

105

Rated conditional short-circuit current with upstream


fuses4)
At 50/60 Hz 690 V AC, rms value
Max. rated current In of the fuses
Permissible let-through current of the fuses
Maximum permissible let-through I2t value

kA

100

100

100

100

80

80

50

A
kA
kA2s

63
8
55

80
10
55

160
17
223

160
17
223

400
305)
1000

400
305)
1000

630
405)
2600

Permissible let-through current of an upstream circuit


breaker
At 50/60 Hz 690 V AC, peak value

kA

15

25

25

32

Rated short-circuit making capacity without fuses


At AC 50 Hz/60 Hz 690 V, peak value

kA

20

25

35

500

650

1000

1280

2000

3200

5040

A
kW

63
30

80
40

125
65

160
80

250
132

400
200

6306)
350

500

640

1000

1280

2000

3200

3200

A
A
kW

63
63
40

80
80
50

125
125
90

160
160
110

250
250
185

400
400
280

630
400
280

500

500

1000

1280

2000

3200

3200

A
A
kW

63
63
50

80
63
50

125
125
110

160
160
150

250
250
220

400
400
375

630
400
375

A
A

250
63

260
63

500
125

640
160

10008)
2509)

1600
400

1600
400

Rated short-time current Icw


(1 s current, rms value)

kA

2.5

2.5

3.2

3.2

11

15

Permissible ambient temperature

C
C

-25 ... +55 for operation3)


-50 ... +80 when stored
15000

15 000

12 000

12 000

12 000

Conventional free-air thermal current Ith

2)

Rated operational voltage Ue

Switching capacity (infeed from the top or bottom)


At 400 V AC
Breaking current Ic (at p.f. = 0.35, rms value)
Rated operational current Ie at
- AC-21A, AC-22A, AC-23A
Motor switching capacity AC-23A
At 500 V AC
Breaking current Ic (at p.f. = 0.35, rms value)
Rated operational current Ie at
- AC-21A, AC-22A
- AC-23A
Motor switching capacity AC-23A
At 690 V AC
Breaking current Ic (at p.f. = 0.35, rms value)
Rated operational current Ie at
- AC-21A, AC-22A
- AC-23A
Motor switching capacity AC-23A
At 440 V DC (3 conducting paths series-connected)7)
Breaking current Ic (L/R = 15 ms)
Rated operational current Ie at DC-23A

Mechanical endurance, operating cycles

15 000

Degree of protection

IP00/IP20 (from the operator side, with busbar and terminal covers)

15 000

Power loss of the switch disconnector at Ith

12

22

22

33

72

170

Main conductor connections


Busbar systems, max. dimensions (w x t)
Cable lug, max. conductor cross-section (stranded)

mm
mm2

25 x 9
35

25 x 9
35

45 x 10
70

45 x 10
120

40 x 12
150

40 x 15
2 x 240

Nm

6 ... 7.5
M6

6 ... 7.5
M6

7 ... 10
M6

18 ... 22
M8

35 ... 45
M10

40 x 12
2 x 150 or
1 x 240
35 ... 45
M10

mm
mm2

---

---

---

---

20 x 2.5
70

20 x 2.5
120

20 x 2.5
120

Tightening torque
Terminal screws
Protective conductor connections
Flat bars
Cable lug, max. conductor cross-section (stranded)
1)

Technical specifications for approval on request.

5)

3ND1 switchgear protection fuse.

2)

Configuring note: Max. permissible operating temperature at connections


100 C.

6)

AC-23B.

7)

220 V DC (L1 and L3 series-connected) or 110 V DC


(one conducting path) at DC-23A.

8)

At 440 V L/R = 4 ms, at 220 V L/R = 15 ms.

9)

At 440 V DC-22A, at 220 V DC-23A.

3)

With 3KA58 for operation -25 C ... +35 C, 570 A at 55 C.

4)

Only available with fuses 3NA3 8, 3NA3 2 or 3ND1 8, 3ND1 2


(otherwise only 105 kA/50 kA).

7/32

Siemens LV 10.1 2011

35 ... 45
M10

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Introduction
Standards

IEC 60947-1, IEC 60947-3

Type

3KE42

3KE43

3KE44

3KE45

Rated uninterrupted current Iu

250

400

630

1000

Rated insulation voltage Ui

AC 1000, DC 1200

Rated impulse withstand voltage Uimp

kV

50/60 Hz AC

690

DC

440 (3 conducting paths series-connected)

220 (2 conducting paths series-connected)

Rated short-circuit making capacity Icm


At 50/60 Hz 690 V AC, peak value

kA

35

35

60

60

Rated short-circuit making capacity with upstream fuses


At 50/60 Hz 690 V AC, peak value

kA

105

105

105

84

Rated conditional short-circuit current with upstream


fuses
At 50/60 Hz 690 V AC (rms value)

50

50

50

40

Maximum permissible let-through I2t value

kA2s

2150

2150

5400

19000

Rated operational voltage Ue

Permissible let-through current of an upstream circuit


breaker
At 50/60 Hz 690 V AC, peak value

kA

35

35

60

60

Max. rated current In of the fuse

400

400

630

1000

Permissible let-through current of the fuses (peak value)

kA

38

38

60

75

1000

1000

2520

2520

Switching capacity (infeed from the top or bottom)


At 400 V AC
Breaking current Ic (at p.f. = 0.35, rms value)
Rated operational current Ie at
- AC-21A

250

400

630

1000

- AC-22A

250

330

630

800

- AC-23A

125

125

315

315

1000

1000

2520

2520

At 500 V AC
Breaking current Ic (at p.f. = 0.35, rms value)
Rated operational current Ie at
- AC-21A

250

400

630

1000

- AC-22A

250

330

630

800

- AC-23A

125

125

315

315

1 000

1000

2520

2520

At 690 V AC
Breaking current Ic (at p.f. = 0.35, rms value)
Rated operational current Ie at
- AC-21A

250

400

630

1000

- AC-22A

250

330

630

800

- AC-23A

125

125

315

315

1000

1000

2520

2520

- DC-21A

250

400

630

1000

- DC-22A

250

250

630

630

kA

12.5

12.5

21

21

-25 ... +55 for operation

-50 ... +80 when stored

At 440 V DC (3 conducting paths series-connected)


Breaking current Ic (L/R = 5 ms)
Rated operational current Ie at

Rated short-time current Icw


(1 s current, rms value)
Permissible ambient temperature
Mechanical endurance, operating cycles

10 000
IP00

Degree of protection
W

15

33

78

180

Busbar systems, max. dimensions (w x t)

mm

25 x 10

25 x 10

2 x 40 x 10

2 x 40 x 10

Cable lug, max. conductor cross-section (stranded)

mm2

2 x 150

2 x 150, 1 x 240

2 x 240

2 x 240

Power loss of the switch disconnector at Ith


Main conductor connections

Siemens LV 10.1 2011

7/33

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Floor mounting

Applications
3KA switch disconnectors are implemented as main switches
and EMERGENCY-STOP switches for normal switching duty and
isolation of main circuits and auxiliary circuits. Another field of
application is the switching of induction motors and other loads
in the event of maintenance and repair.

Main and EMERGENCY-STOP switches are manually operated


switch disconnectors according to IEC 60947-3 and
EN 60947-3 and comply with the conditions for switch disconnectors and the requirements of the machinery directive
EN 60204-1.

Selection and ordering data


All switch disconnectors with degree of protection IP00
Conductor connecting screws are generally included in the scope of supply
Rated uninterrupted current Iu

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

kg

Weight
per PU
approx.

Complete versions with 8UC7 door-coupling rotary operating


mechanism (black handle)
3-pole for motor loads and for power distribution
63
80
125
160

B
B
B
B

3KA50 30-1GE01
3KA51 30-1GE01
3KA52 30-1GE01
3KA53 30-1GE01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

1.444
1.403
2.383
2.426

250
400
630

B
B
B

3KA55 30-1GE01
3KA57 30-1GE01
3KA58 30-1GE01

1
1
1

1 unit
1 unit
1 unit

103
103
103

5.475
5.556
6.128

63
80
125
160

B
B
B
B

3KA50 40-1GE01
3KA51 40-1GE01
3KA52 40-1GE01
3KA53 40-1GE01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

2.498
2.540
2.490
2.458

250
400
630

B
B
B

3KA55 40-1GE01
3KA57 40-1GE01
3KA58 40-1GE01

1
1
1

1 unit
1 unit
1 unit

103
103
103

6.038
5.154
6.595

4-pole1) for power distribution

Basic switch versions without handle


3-pole for motor loads and for power distribution

3KA53 30-1AE01

63
80
125
160

B
B
B
}

3KA50 30-1AE01
3KA51 30-1AE01
3KA52 30-1AE01
3KA53 30-1AE01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.946
0.918
1.880
2.028

250
400
630

B
B
B

3KA55 30-1AE01
3KA57 30-1AE01
3KA58 30-1AE01

1
1
1

1 unit
1 unit
1 unit

103
103
103

4.514
4.630
5.151

63
80
125
160

B
B
B
B

3KA50 40-1AE01
3KA51 40-1AE01
3KA52 40-1AE01
3KA53 40-1AE01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

2.100
2.112
2.090
2.240

250
400
630

C
B
B

3KA55 40-1AE01
3KA57 40-1AE01
3KA58 40-1AE01

1
1
1

1 unit
1 unit
1 unit

103
103
103

5.042
5.195
5.740

4-pole1) for power distribution

3KA53 40-1AE01

8UC7 EMERGENCY-STOP door-coupling rotary operating


mechanisms (red handle, yellow indicator plate) for basic switch
versions without handle
3-pole for motor loads and for power distribution
63
80
125
160

B
B
B
B

8UC71 21-3BB10
8UC71 21-3BB10
8UC72 22-3BB20
8UC72 22-3BB20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.200
0.200
0.200
0.200

250
400
630

B
B
B

8UC73 23-3BB30
8UC73 23-3BB30
8UC73 23-3BB30

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.200
0.200
0.200

63
80
125
160

B
B
B
B

8UC72 22-3BB20
8UC72 22-3BB20
8UC72 22-3BB20
8UC72 22-3BB20

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.200
0.200
0.200
0.200

250
400
630

B
B
B

8UC73 23-3BB30
8UC73 23-3BB30
8UC73 23-3BB30

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.200
0.200
0.200

8UC71 21-3BB10
4-pole1) for power distribution

1)

Rated values reduced in the event of strong harmonics caused by frequency converter operation.

For 8UC7 EMERGENCY-STOP door-coupling rotary operating


mechanisms (red handle, yellow indicator plate),
see Accessories.
* You can order this quantity or a multiple thereof.

7/34

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Floor mounting
Rated uninterrupted current Iu

DT

3-pole, assembly kits for mounting


in control cabinet side panels

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

Assembly kits (IP40 from front)


Comprising: Lockable handle and
three terminal covers for the infeed
side
Order No.
A

Price
per PU

kg

Black handle
63
80
125
160

B
B
B
B

3KX3 516-2AA
3KX3 516-2AA
3KX3 536-2AA
3KX3 536-2AA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.591
0.591
0.843
0.843

250
400
630

B
B
B

3KX3 556-2AA
3KX3 556-2AA
3KX3 556-2AA

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.560
1.560
1.560

3KA53 30-1AE01 with


3KX3 536-2AA

EMERGENCY-STOP red handle


63
80
125
160

B
B
B
B

3KX3 516-2BA
3KX3 516-2BA
3KX3 536-2BA
3KX3 536-2BA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.584
0.584
0.860
0.860

250
400
630

B
B
B

3KX3 556-2BA
3KX3 556-2BA
3KX3 556-2BA

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.590
1.590
1.590

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/35

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Floor mounting
All switch disconnectors with degree of protection IP00
With high speed closing and opening
Conductor connecting screws are generally included in the scope of supply
Rated uninterrupted current Iu

DT

3-pole, operating mechanism and


actuation from the front
Direct operating mechanisms
Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.
kg

Complete versions with black handle


250
400
630
1000

B
B
B
B

3KE42 30-0BA
3KE43 30-0BA
3KE44 30-0BA
3KE45 30-0BA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

4.210
4.178
7.184
7.838

B
B
B
B

3KE42 30-0AA
3KE43 30-0AA
3KE44 30-0AA
3KE45 30-0AA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

3.879
3.870
6.915
7.427

8UC93 71
+
3KX2 210-0H

1 unit

103

0.146

1 unit

103

0.236

8UC93 71
+
3KX2 210-0H

1 unit

103

0.146

1 unit

103

0.236

8UC93 75
+
3KX2 210-0H

1 unit

103

0.165

1 unit

103

0.236

8UC93 75
+
3KX2 210-0H

1 unit

103

0.165

1 unit

103

0.236

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

3KE43 30-0BA

Basic switch versions without handle


250
400
630
1000

EMERGENCY-STOP red handles + coupling sockets


for basic switch versions without handle
250

B
400

B
B

630

B
B

1000

B
B

Rated uninterrupted current Iu

DT

3-pole, operating mechanism and


actuation from the front
Door-coupling rotary operating
mechanisms (lockable)
Order No.

Price
per PU

kg

Complete versions with 8UC7 door-coupling rotary operating


mechanism (black handle)
250
400
630
1000

B
B
B
B

3KE42 30-0GA
3KE43 30-0GA
3KE44 30-0GA
3KE45 30-0GA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

5.032
5.041
7.885
8.532

B
B
B
B

3KE42 30-0AA
3KE43 30-0AA
3KE44 30-0AA
3KE45 30-0AA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

3.879
3.870
6.915
7.427

8UC73 24-3BB44

1 unit

103

0.200

Basic switch versions without handle


250
400
630
1000

8UC7 EMERGENCY-STOP door-coupling rotary operating


mechanisms (red handle, yellow indicator plate)
for basic switch versions without handle
250, 400, 630, 1000

* You can order this quantity or a multiple thereof.

7/36

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Floor mounting
Rated uninterrupted current Iu

DT

3-pole, rear operating mechanism


and actuation
Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.
kg

Basic switch versions without handle


Direct operating mechanisms
250
400
630
1000

B
B
C
C

3KE42 30-0CA
3KE43 30-0CA
3KE44 30-0CA
3KE45 30-0CA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

5.306
5.030
7.395
7.990

B
B
C
C

3KE42 30-0CA
3KE43 30-0CA
3KE44 30-0CA
3KE45 30-0CA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

5.306
5.030
7.395
7.990

8UC93 70
+
8UB95 30
+
8UC96 31-0B

1 unit

103

0.128

1 unit

103

0.028

1 unit

103

0.011

8UC93 70
+
8UB95 30
+
8UC96 31-0B

1 unit

103

0.128

1 unit

103

0.028

1 unit

103

0.011

8UC93 74
+

1 unit

103

0.145

8UB95 30
+
8UC96 31-0B

1 unit

103

0.028

1 unit

103

0.011

8UC93 74
+
8UB95 30
+
8UC96 31-0B

1 unit

103

0.145

1 unit

103

0.028

1 unit

103

0.011

8UC93 70
+
8UC95 63
+
8UC96 31-0B

1 unit

103

0.128

1 unit

103

0.271

1 unit

103

0.011

8UC93 70
+
8UC95 63
+
8UC96 31-0B

1 unit

103

0.128

1 unit

103

0.271

1 unit

103

0.011

8UC93 74
+
8UC95 63
+
8UC96 31-0B

1 unit

103

0.145

1 unit

103

0.271

1 unit

103

0.011

8UC93 74
+
8UC95 63
+
8UC96 31-0B

1 unit

103

0.145

1 unit

103

0.271

1 unit

103

0.011

Direct operating mechanisms (lockable)


250
400
630
1000

Handles (black) + masking plates + display plates (silver)


for basic switch versions without handle
Direct operating mechanisms
250

A
A
400

B
A
A

630

A
1000

B
A
A

Direct operating mechanisms (lockable)


250

B
B
A

400

B
B
A

630

B
B
A

1000

B
B
A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/37

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Floor mounting
Rated uninterrupted current Iu

DT

3-pole, rear operating mechanism


and actuation
Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.
kg

EMERGENCY-STOP red handles + masking plates + display plates


(yellow) for basic switch versions without handle
Direct operating mechanisms
250

B
A
A

400

B
A
A

630

B
A
A

1000

B
A
A

8UC93 71
+
8UB95 30
+
8UC96 33-0B

1 unit

103

0.146

1 unit

103

0.028

1 unit

103

0.011

8UC93 71
+
8UB95 30
+
8UC96 33-0B

1 unit

103

0.146

1 unit

103

0.028

1 unit

103

0.011

8UC93 75
+
8UB95 30
+
8UC96 33-0B

1 unit

103

0.165

1 unit

103

0.028

1 unit

103

0.011

8UC93 75
+
8UB95 30
+
8UC96 33-0B

1 unit

103

0.165

1 unit

103

0.028

1 unit

103

0.011

8UC93 71
+
8UC95 63
+
8UC96 33-0B

1 unit

103

0.146

1 unit

103

0.271

1 unit

103

0.011

8UC93 71
+
8UC95 63
+
8UC96 33-0B

1 unit

103

0.146

1 unit

103

0.271

1 unit

103

0.011

8UC93 75
+
8UC95 63
+
8UC96 33-0B

1 unit

103

0.165

1 unit

103

0.271

1 unit

103

0.011

8UC93 75
+
8UC95 63
+
8UC96 33-0B

1 unit

103

0.165

1 unit

103

0.271

1 unit

103

0.011

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

Direct operating mechanisms (lockable)


250

B
B
A

400

B
B
A

630

B
B
A

1000

B
B
A

Rated uninterrupted current Iu

DT

3-pole, rear rotary operating


mechanisms (lockable)
Door-coupling rotary operating
mechanisms (lockable)
Order No.

Price
per PU

kg

Basic switch versions without handle


250
400
630
1000

B
B
C
C

3KE42 30-0CA
3KE43 30-0CA
3KE44 30-0CA
3KE45 30-0CA

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

5.306
5.030
7.395
7.990

8UC73 14-1BB44

1 unit

103

0.200

8UC73 24-3BB44

1 unit

103

0.200

8UC7 door-coupling rotary operating mechanisms (black handle)


for basic switch versions without handle
250, 400, 630, 1000

8UC7 EMERGENCY-STOP door-coupling rotary operating


mechanisms (red handle, yellow indicator plate)
for basic switch versions without handle
250, 400, 630, 1000

* You can order this quantity or a multiple thereof.

7/38

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Molded-plastic enclosures

Benefits
Lockable with 3 padlocks
Generous terminal compartment
Degree of protection IP65

Maintenance-free
Easy mounting

Application
Our master and EMERGENCY-STOP switches provide absolute
safety, even during maintenance and repair work. All-round
safety for people and machines.

building and industrial installations as well as the food and


chemical industry. Even with the enclosure open, they comply
with protection class 2. IP20 is the minimum!

With their high degree of protection IP65, they can even withstand dust and water spray, providing unparalleled safety in the

Selection and ordering data


Main
Auxiliary
contact
contacts
elements

P/AC-23A
at
380 ...
400 V
kW

Iu
At 660/
690 V
kW

Conductor crosssection of main


conductor/PEN
mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Main control switches complete with rotary operating mechanism, black1)


3

--

65
80
132

110
150
220

125
160
250

200

375

400

350
315

375
315

35/352)
120/702)
150/702)

2 150 or
1 240/120
630
2 240/120
3)
2 240/240
800

C
C
C

8HP2 707
8HP2 711
8HP2 712

1
1
1

1 unit
1 unit
1 unit

046
046
046

5.240
8.039
12.242

8HP2 717

1 unit

046

12.378

C
C

8HP2 718
8HP2 738

1
1

1 unit
1 unit

046
046

13.050
14.290

C
C
C

8HP2 747
8HP2 748
8HP2 761

1
1
1

1 unit
1 unit
1 unit

046
046
046

5.217
7.992
12.340

8HP2 762

1 unit

046

12.354

C
C

8HP2 763
8HP2 758

1
1

1 unit
1 unit

046
046

12.875
14.329

8HP2 7..

EMERGENCY-STOP switches complete with rotary operating mechanism,


red/yellow1)
3

--

65
80
132

110
150
220

125
160
250

200

375

400

350
315

375
315

35/352)
120/702)
150/702)

2 150 or
1 240/120
630
2 240/120
3)
2 240/240
800

1)

With PE/ground or N terminal.

2)

For a fifth conductor, the same terminal can be fitted additionally.

3)

At ambient temperatures up to 35 C.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/39

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Accessories

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3KA50 30/3KA51 30
Terminal covers
For 3-pole devices (1set = 6 units)
For 4-pole devices (1set = 8 units)

3KX3 552-3DA01

3KX3 516-1AA

}
B

3KX3 552-3DA01
3KX3 552-3DB01

1
1

1 unit
1 unit

103
103

0.077
0.102

C
B

8UC71 11-1BB10
8UC71 21-3BB10

1
1

1 unit
1 unit

103
103

0.200
0.200

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm

3KX3 516-1AA

1 unit

103

0.088

Extension shaft 300 mm long

8UC60 31

1 unit

103

0.068

Extension shaft 600 mm long

8UC60 81

1 unit

103

0.136

Shaft connecting pieces

8UC60 21

1 unit

103

0.031

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

Terminal covers
For 3-pole 3KA52 devices (1set = 6 units)

3KX3 552-3DA01

1 unit

103

0.077

For 3KA53

3KX3 553-3DA01

1 unit

103

0.147

For 4-pole 3KA52 devices (1set = 8 units)

3KX3 552-3DB01

1 unit

103

0.102

For 3KA53

3KX3 553-3DB01

1 unit

103

0.170

C
B

8UC72 12-1BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm

3KX3 536-1AA

1 unit

103

0.155

Extension shaft 300 mm long

8UC60 32

1 unit

103

0.132

Extension shaft 600 mm long

8UC60 82

1 unit

103

0.265

Shaft connecting pieces

8UC60 22

1 unit

103

0.023

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

1 NO + 1 NC, 20 ms leading

3KX3 552-3EA01

1 unit

103

0.019

Terminal covers
For 3-pole devices (1set = 6 units)
For 4-pole devices (1set = 8 units)

}
B

3KX3 557-3DA01
3KX3 557-3DB01

1
1

1 unit
1 unit

103
103

0.277
0.362

C
B

8UC73 13-1BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm

3KX3 176-1E

1 unit

103

0.285

Extension shaft 300 mm long

8UC60 33

1 unit

103

0.217

Extension shaft 600 mm long

8UC60 83

1 unit

103

0.430

Shaft connecting pieces

8UC60 23

1 unit

103

0.085

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

1 NO + 1 NC, 20 ms leading

3KX3 552-3EA01

1 unit

103

0.019

Door-coupling rotary operating mechanisms


IP65
Black handle, shaft 300 mm
EMERGENCY-STOP (yellow/red),
square shaft 300 mm

Auxiliary switches

3SB14 00-0A

3KA50 40/3KA51 40/3KA52/3KA53

3KX3 552-3DA01

Door-coupling rotary operating mechanisms


IP65
Black handle, shaft 300 mm
EMERGENCY-STOP (yellow/red),
square shaft 300 mm

8UC72 12-1BB20

Auxiliary switches

3SB14 00-0A

3KA55/3KA57/3KA58

Door-coupling rotary operating mechanisms


IP65
Black handle, shaft 300 mm
EMERGENCY-STOP (yellow/red),
square shaft 300 mm

3KX3 176-1E

Auxiliary switches

3SB14 00-0A

* You can order this quantity or a multiple thereof.

7/40

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Accessories
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3KE42/3KE43
Changeover switches
Changeover switches with interruption
Switch I ON Switch II OFF
Switch I OFF Switch II OFF
Switch I ON Switch II ON

3KX2 210-0D

1 unit

103

2.442

Door-coupling rotary operating


mechanisms IP65
Handle (black), shaft 300 mm

8UC74 14-1BF44

1 unit

103

0.200

Direct operating mechanisms


Twin handle (black) for fixed mounting

8UC93 81

1 unit

103

0.264

3KX2 210-0E

1 unit

103

2.448

8UC74 14-1FG44

1 unit

103

0.200

8UC93 81

1 unit

103

0.264

Switch I ON Switch II ON
Switch I OFF Switch II OFF

3KX2 250-1A

1 unit

103

0.750

Door-coupling rotary operating


mechanisms IP65
Handle (black), shaft 300 mm

8UC74 14-1BB44

1 unit

103

0.200

EMERGENCY-STOP door-coupling rotary


operating mechanisms IP65
Twin handle (red), shaft 300 mm

8UC74 24-3BB44

1 unit

103

0.200

Direct operating mechanisms


Handle (black) for fixed mounting

8UC93 81

1 unit

103

0.264

3KX3 557-3DA01

1 unit

103

0.277

C
B

8UC73 14-1BB44
8UC73 24-3BB44

1
1

1 unit
1 unit

103
103

0.200
0.200

Extension shaft 300 mm long

8UC60 34

1 unit

103

0.315

Extension shaft 600 mm long

8UC60 84

1 unit

103

0.640

Auxiliary switches with switching cam


1 NO + 1 NC (complete mounting kit)

3KX2 231-1A

1 unit

103

0.049

Grounding brackets

3KX2 252-1A

1 unit

103

0.049

Arc chute
(spare part with 3 arc-splitter assemblies)

3KY2 202-0B

1 unit

103

0.640

Arcing contacts
(spare part with 3 fixed and 3 movable contacts)

3KY2 204-0A

1 unit

103

0.202

3KX2 210-0D

Changeover switches without interruption


Switch I ON Switch II OFF
B
Switch I ON Switch II ON
Switch I OFF Switch II ON
Door-coupling rotary operating
mechanisms IP65
Handle (black), shaft 300 mm
Direct operating mechanisms
Twin handle (black) for fixed mounting

Parallel switches

Further accessories
Terminal covers
(1 set = 6 units)

3KX3 557-3DA01
Door-coupling rotary operating
mechanisms IP65
Black handle, shaft 300 mm
EMERGENCY-STOP (yellow/red),
square shaft 300 mm

3KX2 231-1A

3KY2 204-0A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/41

Siemens AG 2011

Switch Disconnectors
SENTRON 3KA, 3KE Switch Disconnectors up to 1000 A
Accessories
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3KE44/3KE45
Changeover switches
Changeover switches with interruption
Switch I ON Switch II OFF
Switch I OFF Switch II OFF
Switch I OFF Switch II ON
3KX2 210-0D

Door-coupling rotary operating


C
mechanisms IP65
Handle (black) for changeover switches with
interruption, shaft 300 mm
Direct operating mechanisms
Twin handle (black) for fixed mounting

Changeover switches without interruption


Switch I ON Switch II OFF
B
Switch I ON Switch II ON
Switch I OFF Switch II ON

3KX2 210-0D

1 unit

103

2.442

8UC74 14-1BF44

1 unit

103

0.200

8UC93 81

1 unit

103

0.264

3KX2 210-0E

1 unit

103

2.448

Door-coupling rotary operating


mechanisms IP65
Handle (black) for changeover switches
without interruption, shaft 300 mm

8UC74 14-1FG44

1 unit

103

0.200

Direct operating mechanisms


Twin handle (black) for fixed mounting

8UC93 81

1 unit

103

0.264

Switch I ON Switch II ON
Switch I OFF Switch II OFF

3KX2 250-1A

1 unit

103

0.750

Door-coupling rotary operating


mechanisms IP65
Handle (black), shaft 300 mm

8UC74 14-1BB44

1 unit

103

0.200

EMERGENCY-STOP door-coupling rotary


operating mechanisms IP65
Twin handle (red), shaft 300 mm

8UC74 24-3BB44

1 unit

103

0.200

Direct operating mechanisms


Handle (black) for fixed mounting

8UC93 81

1 unit

103

0.264

3KX2 252-0C

1 unit

103

0.424

C
B

8UC73 14-1BB44
8UC73 24-3BB44

1
1

1 unit
1 unit

103
103

0.200
0.200

Extension shaft 300 mm long

8UC60 34

1 unit

103

0.315

Extension shaft 600 mm long

8UC60 84

1 unit

103

0.640

Auxiliary switches
1 NO + 1 NC (complete mounting kit)

3KX2 231-1A

1 unit

103

0.049

Grounding brackets

3KX2 252-1A

1 unit

103

0.049

Arc chute
(spare part with 3 arc-splitter assemblies)

3KY2 232-0A

1 unit

103

1.040

Arcing contacts
Spare part with 3 fixed and 3 movable contacts

3KY2 234-0A

1 unit

103

0.105

Parallel switches

Further accessories
Terminal covers
(top and bottom)
Door-coupling rotary operating
mechanisms IP65
Black handle, shaft 300 mm
EMERGENCY-STOP (yellow/red),
square shaft 300 mm

3KX2 231-1A

3KY2 232-0A

* You can order this quantity or a multiple thereof.

7/42

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Introduction

Overview

NSE0_01557b

1
4

9
8
3
3KL or 3KM basic device
Plug-in contact strip for 3KM
3

Fuses, optionally BS-88 or LV HRC fuses


Terminal cover, IP20 (vertical to operator side)
Coupling driver with extension shaft

Optional
8UC9 knob for fixed mounting in standard version (black) or
EMERGENCY-STOP version (red), or
9 8UC7 door-coupling rotary operating mechanism in standard
version (ti-grey) or EMERGENCY-STOP version (red/yellow)

Standard products from the Siemens 3SB1 range


are used as auxiliary switches.
Single-pole terminal cover from 63 A to 630 A, IP20
(vertical to operator side)

All components from the switch to the actuator are provided with
non-interchangeability features.

All switch disconnectors feature double contact interruption and


an isolating distance. As a result, the fuses of the switch disconnectors are de-energized in the OFF position.
Generally all 3K.5 switch disconnectors can can be secured to
the shaft with padlock against unauthorized reclosing.

Identical accessories for 3KA load disconnectors and 3KL and


3KM load disconnectors with fuses simplifies inventory.
Please inquire about a special variant with reduced values that
is particularly resistant to atmospheres high in sulfur, e.g. in the
paper and cellulose processing industries.

Application
3KL switch disconnectors with fuses protect against overload
and short-circuits as main and EMERGENCY-STOP switches of
switch boards, distribution boards, power supply and motor outgoing feeders.
In conjunction with Siemens SITOR semiconductor fuses, they
are also used in UPS systems, frequency converters and capacitor control systems.

All 3K switch disconnectors are climate-proof and meet the


requirements of IEC 60947-1 and IEC 60947-3.

Siemens LV 10.1 2011

7/43

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Introduction

Technical specifications
Standards

IEC 60947-1, IEC 60947-3


3KL50

3KL521)

3KL531)

3KL551)

3KL571)

3KL611)

3KL621)

Rated uninterrupted current Iu


For fuse links acc. to DIN 43620,
(when SITOR semiconductor fuses are used,
a reduction of rated current is necessary,
see reference to technical information at start of chapter)

A
Size

63
00 and
000

125
00 and
000

160
00 and
000

250
1 and 2

400
1 and 2

630
3 and 2

800
3 and 2

Conventional free-air thermal current Ith2)

63

125

160

250

400

630

800

Rated insulation voltage Ui

690

1000

1000

1000

1000

1000

1000

Rated impulse withstand voltage Uimp

kV

Rated operational voltage Ue


50/60 Hz AC
DC

V
V

690
440 (3 conducting paths series-connected)
220 (2 conducting paths series-connected) 3)

Rated short-circuit making capacity with fuses


peak value at 50/60 Hz 690 V AC

kA

220

220

220

176

176

105

105

Rated conditional short-circuit current with fuses

kA

100

100

100

80

80

50

50

Max. rated current In of the fuses

80

160

160

400

400

6304)

800

Max. permissible power loss of the installed fuse


NH
BS

W
W

6
9
8 (A2/A3) 11.5 (A4)

11.5
11.5

32
32

45
45

48
48

62
60.5

Permissible let-through current of the fuses

kA

17

17

305)

305)

50

50

Maximum permissible let-through I2t value

kA2s

55

223

223

1000

1000

5400

10500

At 400 V AC
Breaking current Ic (at p.f. = 0.35, rms)
Rated operational current Ie with AC-21A, AC-22A, AC-23A
Motor switching capacity AC-23A

A
A
kW

500
63
30

1000
125
65

1280
160
80

2000
250
132

3200
400
200

5100
6306)
335

6400
8006)
400

At 500 V AC
Breaking current Ic (at p.f. = 0.35, rms)
Rated operational current Ie with AC-21A, AC-22A, AC-23A
Motor switching capacity AC-23A

A
A
kW

500
63
40

1000
125
90

1280
160
110

2000
250
185

3200
400
280

5100
6306)
425

6400
8006)
500

At 690 V AC
Breaking current Ic (at p.f. = 0.35, rms)
Rated operational current Ie with AC-21A, AC-22A, AC-23A
Motor switching capacity AC-23A

A
A
kW

500
63
50

1000
125
110

1280
160
150

2000
250
220

3200
400
375

5100
6305)
560

6400
8005)
700

At 440 V DC (3 conducting paths series-connected)7)


Breaking current Ic (L/R = 15 ms)
Rated operational current Ie at DC-23A

A
A

250
63

500
125

640
160

10008)
25010)

1600
400

25209)
63010)

25209)
63010)

Rated short-time current Icw (1 s current, rms value)

kA

2.5

3.2

3.2

11

32

32

Permissible ambient temperature

C
C

-25 ... +55 for operation4),


-50 ... +80 when stored
12000

12000

3000

3000

Type

At 50/60 Hz 690 V AC (rms value)

Switching capacity (infeed from the top or bottom)

Mechanical endurance, operating cycles

15000

Degree of protection

IP00/IP20 (from the operator side, with fuse and terminal covers)

15000

15000

8.5

22

36

33

86

140

225

Main conductor connections


Busbar systems, max. dimensions (w x t)

mm

25 x 9

45 x 10

45 x 10

40 x 12

40 x 15

40 x 17

40 x 17

Cable lug, max. conductor cross-section (stranded)

mm2

35

70

120

150

2 x 150 or 2 x 240
1 x 240

2 x 240

Tightening torque
Terminal screws

Nm

6 ... 7.5
M6

7 ... 10
M6

18 ... 22
M8

35 ... 45
M10

35 ... 45
M10

56
M12

56
M12

mm
mm2

---

---

---

20 x 2.5
70

20 x 2.5
120

---

---

Power loss of the switch disconnector at Ith


(plus power loss of the fuses)

Protective conductor connections


Flat bars
Cable lug, max. conductor cross-section (stranded)
1)

Technical specifications for approval on request.

Note:

2)

Configuring note: Max. permissible operating temperature for fuse blades


135 C, for connections 100 C.

For the 3KL switch disconnectors, complete kits for standard


and EMERGENCY-STOP application are available for installation
in the side and rear panels of control cabinets.

3)

110 V (one conducting path).

4)

With 3KL61 for operation -25 C ... +35 C, at +55 C: Ith = 570 A.

5)

With 3ND1 switchgear protection fuse.

6)

AC-23B.

7)

220 V DC (L1 and L3 series-connected) or 110 V DC


(one conducting path) at DC-23A.

8)

At 440 V L/R = 4 ms, at 220 V L/R = 15 ms.

9)

Only DC-22A (L/R = 2.5 ms)

10)

At 440 V DC-22A, at 220 V DC-23A.

7/44

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Floor mounting

Selection and ordering data


All switch disconnectors with degree of protection IP00
Conductor connecting screws and fuse partitions are generally included in the scope of supply
Rated uninterrupted
current Iu

LV HRC fuse links1)


acc. to DIN 436202)
Size

DT

Order No.

Operational
class

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Complete versions with 8UC7 door-coupling rotary operating


mechanism (black handle)
3-pole for NH fuse systems
63
125
160
250

00 and 000
00 and 000
00 and 000
1 and 2

gG, aM
gG, aM
gG, aM
gG, aM

B
B
B
B

3KL50 30-1GB01
3KL52 30-1GB01
3KL53 30-1GB01
3KL55 30-1GB01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

1.460
2.414
2.600
6.112

400
630
6303)
8003)

2 and 1
3 and 2
3 and 23)
3 and 23)

gG, aM
gG, aM
gG, aM3)
gG, aM3)

B
B
D
C

3KL57 30-1GB01
3KL61 30-1GB00
3KL61 30-1GB02
3KL62 30-1GB02

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
113
113
113

6.067
18.070
15.200
15.200

4-pole for NH fuse systems


63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
C

3KL50 40-1GB01
3KL52 40-1GB01
3KL53 40-1GB01

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.542
2.623
2.776

250
400
630

1 and 2
2 and 1
3 and 2

gG, aM
gG, aM
gG, aM

B
B
B

3KL55 40-1GB01
3KL57 40-1GB01
3KL61 40-1GB00

1
1
1

1 unit
1 unit
1 unit

103
103
113

6.642
6.886
16.690

3-pole for fuses acc. to BS 88


63
125

Form A2/A3
Form A2/A3

B
B

3KL50 30-1GG01
3KL52 30-1GG01

1
1

1 unit
1 unit

103
103

1.455
2.360

125
160

Form A4
Form A4

B
B

3KL52 30-1GJ01
3KL53 30-1GJ01

1
1

1 unit
1 unit

103
103

2.406
2.575

250
400

Form B1-B3
Form B1-B3

B
B

3KL55 30-1GG01
3KL57 30-1GG01

1
1

1 unit
1 unit

103
103

6.115
6.582

630
800

Form C1-C3
Form C1-C3

C
D

3KL61 30-1GG00
3KL62 30-1GG00

1
1

1 unit
1 unit

113
113

16.278
15.400

4-pole for fuses acc. to BS 88


63
125

Form A2/A3
Form A2/A3

B
B

3KL50 40-1GG01
3KL52 40-1GG01

1
1

1 unit
1 unit

103
103

2.563
2.560

125
160

Form A4
Form A4

B
B

3KL52 40-1GJ01
3KL53 40-1GJ01

1
1

1 unit
1 unit

103
103

2.614
2.780

250
400

Form B1-B3
Form B1-B3

B
B

3KL55 40-1GG01
3KL57 40-1GG01

1
1

1 unit
1 unit

103
103

6.639
7.148

630

Form C1-C3

3KL61 40-1GG00

1 unit

113

16.996

Basic switch versions without handle


3-pole for NH fuse systems

3KL52 30-1AB01

63
125
160
250

00 and 000
00 and 000
00 and 000
1 and 2

gG, aM
gG, aM
gG, aM
gG, aM

}
}
}
}

3KL50 30-1AB01
3KL52 30-1AB01
3KL53 30-1AB01
3KL55 30-1AB01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

1.055
1.989
2.200
5.715

400
630
6303)
8003)

2 and 1
3 and 2
3 and 23)
3 and 23)

gG, aM
gG, aM
gG, aM3)
gG, aM3)

}
A
A
A

3KL57 30-1AB01
3KL61 30-1AB0
3KL61 30-1AB02
3KL62 30-1AB02

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
113
113
113

5.400
17.696
14.000
15.200

4-pole for NH fuse systems


63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
B

3KL50 40-1AB01
3KL52 40-1AB01
3KL53 40-1AB01

1
1
1

1 unit
1 unit
1 unit

103
103
103

2.219
2.195
2.344

250
400
630

1 and 2
2 and 1
3 and 2

gG, aM
gG, aM
gG, aM

B
B
A

3KL55 40-1AB01
3KL57 40-1AB01
3KL61 40-1AB00

1
1
1

1 unit
1 unit
1 unit

103
103
113

5.577
5.670
15.423

3KL52 40-1AB01
3-pole for fuses acc. to BS 88

3KL52 30-1AJ01

63
125

Form A2/A3
Form A2/A3

B
B

3KL50 30-1AG01
3KL52 30-1AG01

1
1

1 unit
1 unit

103
103

0.993
1.939

125
160

Form A4
Form A4

B
B

3KL52 30-1AJ01
3KL53 30-1AJ01

1
1

1 unit
1 unit

103
103

2.033
2.170

250
400

Form B1-B3
Form B1-B3

B
B

3KL55 30-1AG01
3KL57 30-1AG01

1
1

1 unit
1 unit

103
103

5.145
5.666

630
800

Form C1-C3
Form C1-C3

A
C

3KL61 30-1AG00
3KL62 30-1AG00

1
1

1 unit
1 unit

113
113

15.075
14.200

Fuse monitoring through 5TT3 170 safety monitor with a floating


1 NO signaling contact, see chapter 5 "Fuse Systems".

For footnotes, see page 7/46.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/45

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Floor mounting
Rated uninterrupted
current Iu

LV HRC fuse links1)


acc. to DIN 436202)

Size

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Operational
class

kg

4-pole for fuses acc. to BS 88

3KL52 40-1AJ01
with fuses

63
125

Form A2/A3
Form A2/A3

B
B

3KL50 40-1AG01
3KL52 40-1AG01

1
1

1 unit
1 unit

103
103

2.145
2.161

125
160

Form A4
Form A4

B
B

3KL52 40-1AJ01
3KL53 40-1AJ01

1
1

1 unit
1 unit

103
103

2.120
2.230

250
400

Form B1-B3
Form B1-B3

B
B

3KL55 40-1AG01
3KL57 40-1AG01

1
1

1 unit
1 unit

103
103

5.666
6.441

630

Form C1-C3

3KL61 40-1AG00

1 unit

113

15.708

8UC7 EMERGENCY-STOP door-coupling rotary operating mechanisms


(red handle, yellow indicator plate)
for basic switch versions without handle
3-pole for NH fuse systems
63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
B

8UC71 21-3BB10
8UC72 22-3BB20
8UC72 22-3BB20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.200
0.200
0.200

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

8UC73 23-3BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

630

3 and 2

gG, aM

8UC74 24-3BB44
+

1 unit

103

0.200

8UC92 53

1 unit

103

0.115

800

3 and 2

gG, aM

1 unit

103

0.200

8UC74 24-3BB44
+
8UC92 53

1 unit

103

0.115

8UC71 21-3BB10

4-pole for NH fuse systems


63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
B

8UC72 22-3BB20
8UC72 22-3BB20
8UC72 22-3BB20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.200
0.200
0.200

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

8UC73 23-3BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

630

3 and 2

gG, aM

1 unit

103

0.200

8UC74 24-3BB44
+
8UC92 53

1 unit

103

0.115

3-pole for fuses acc. to BS 88


63
125

Form A2/A3
Form A2/A3

B
B

8UC71 21-3BB10
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

125
160

Form A4
Form A4

B
B

8UC72 22-3BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

250
400

Form B1-B3
Form B1-B3

B
B

8UC73 23-3BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

630

Form C1-C3

8UC74 24-3BB44
+
8UC92 53

1 unit

103

0.200

1 unit

103

0.115

800

Form C1-C3

1 unit

103

0.200

8UC74 24-3BB44
+
8UC92 53

1 unit

103

0.115

4-pole for fuses acc. to BS 88


63
125

Form A2/A3
Form A2/A3

B
B

8UC72 22-3BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

125
160

Form A4
Form A4

B
B

8UC72 22-3BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

250
400

Form B1-B3
Form B1-B3

B
B

8UC73 23-3BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

630

Form C1-C3

8UC74 24-3BB44
+
8UC92 53

1 unit

103

0.200

1 unit

103

0.115

Fuse monitoring through 5TT3170 safety monitor with a floating


1 NO signaling contact, see chapter 5 "Fuse Systems".
Footnotes for pages 7/45 and 7/46:
1)

Silver-plated fuse blades. Silver-plated isolating links can be used if


desired.

2)

For the assignment of semiconductor fuses see "Accessories".

3)

With SITOR 3NE fuse links cUus-approved.

* You can order this quantity or a multiple thereof.

7/46

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Front mounting

Selection and ordering data


All switch disconnectors with degree of protection IP00
Conductor connecting screws and fuse partitions are generally included in the scope of supply
Rated uninterrupted
current Iu

LV HRC fuse links1)


acc. to DIN 436202)

Size

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Operational
class

kg

Assembly kits (IP40) comprising: lockable handle, cover for NH fuse


systems (locked in ON state) and three terminal covers for infeed side
for basic switch versions without handle
3-pole, assembly kits for mounting in control cabinet side
panels
Black handle
63
125
160

00
00
00

gG, aM
gG, aM
gG, aM

B
B
B

3KX3 516-3AA
3KX3 526-3AA
3KX3 536-3AA

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.626
0.820
0.880

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

3KX3 556-3AA
3KX3 556-3AA

1
1

1 unit
1 unit

103
103

1.720
1.720

EMERGENCY-STOP red handle


63
125
160

00
00
00

gG, aM
gG, aM
gG, aM

B
B
B

3KX3 516-3BA
3KX3 526-3BA
3KX3 536-3BA

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.625
0.846
0.883

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

3KX3 556-3BA
3KX3 556-3BA

1
1

1 unit
1 unit

103
103

1.690
1.690

Fuse monitoring through 5TT3170 safety monitor with a floating


1 NO signaling contact, see chapter 5 "Fuse Systems".
1)

Silver-plated fuse blades. Silver-plated isolating links can be used if


desired.

2)

For the assignment of semiconductor fuses see "Accessories".

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/47

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Accessories

Selection and ordering data


Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3KL50 30
Terminal covers
3KX3 552-3DA01

For 3-pole devices (1set = 6 units)

3KX3 552-3DA01

1 unit

103

0.077

Fuse covers
(interlock only detachable in the OFF position)

3KX3 517-3AA

1 unit

103

0.041

Cover IP20
For 3-pole devices

3KX3 507-0CA02

1 unit

103

0.400

Fuse partitions
(1 set = 5 units)

3KX3 507-0AA01

1 unit

103

0.044

Lyre-shaped fuse covers


(1 set = 6 units)

3KX3 507-0BA01

1 unit

103

0.033

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm
C
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

8UC71 11-1BB10
8UC71 21-3BB10

1
1

1 unit
1 unit

103
103

0.200
0.200

3KX3 5.7-3AA

3KX3 507-0BA01

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm

3KX3 516-1AA

1 unit

103

0.088

Extension shaft 300 mm long

8UC60 31

1 unit

103

0.068

Extension shaft 600 mm long

8UC60 81

1 unit

103

0.136

Shaft connecting pieces

8UC60 21

1 unit

103

0.031

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

11.90

1 unit

102

0.020

2 NC

3SB14 00-0H

11.90

1 unit

102

0.020

Fuse monitor connections


(1 set = 6 units)

3KX3 505-0AA

1 unit

103

0.014

3KL52

3KX3 552-3DA01

1 unit

103

0.077

3KL53

3KX3 553-3DA01

1 unit

103

0.147

3KL50 40, 3KL52

3KX3 552-3DB01

1 unit

103

0.102

3KL53

3KX3 553-3DB01

1 unit

103

0.170

Fuse covers1)
(interlock only detachable in the OFF position)

3KX3 527-3AA

1 unit

103

0.071

Cover IP20
For 3KL52 3-pole devices

3KX3 527-0CA02

1 unit

103

0.765

Cover IP20
For 3KL53 3-pole devices

3KX3 537-0CA02

1 unit

103

0.765

Fuse partitions
(1 set = 5 units)

3KX3 507-0AA01

1 unit

103

0.044

Lyre-shaped fuse covers


(1 set = 6 units)

3KX3 507-0BA01

1 unit

103

0.033

Auxiliary switches

3SB14 00-0A

3KL50 40/3KL52/3KL53
Terminal covers
For 3-pole devices (1 set = 6 units)
3KX3 552-3DA01

For 4-pole devices (1set = 8 units)

3KX3 5.7-3AA

3KX3 507-0BA01
1)

For 3KX3 527-3AA: Not suitable for use with type A4 BS fuses.

* You can order this quantity or a multiple thereof.

7/48

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Accessories
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm
C
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

8UC72 12-1BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm

3KX3 536-1AA

1 unit

103

0.155

Extension shaft 300 mm long

8UC60 32

1 unit

103

0.132

Extension shaft 600 mm long

8UC60 82

1 unit

103

0.265

Shaft connecting pieces

8UC60 22

1 unit

103

0.023

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

1 NO + 1 NC, 20 ms leading

3KX3 552-3EA01

1 unit

103

0.019

Fuse monitor connections


(1 set = 6 units)

3KX3 505-0AA

1 unit

103

0.014

}
B

3KX3 557-3DA01
3KX3 557-3DB01

1
1

1 unit
1 unit

103
103

0.277
0.362

Fuse covers
(interlock only detachable in the OFF position)

3KX3 557-3AA

1 unit

103

0.212

Cover IP20
For 3-pole devices

3KX3 557-0CA02

1 unit

103

1.235

Fuse partitions
(1 set = 5 units)

3KX3 557-0AA01

1 unit

103

0.162

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm
C
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

8UC73 13-1BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

Auxiliary switches

3SB14 00-0A

3KL55/3KL57
Terminal covers
For 3-pole devices (1set = 6 units)
For 4-pole devices (1set = 8 units)

3KX3 5.7-3AA

Operating mechanisms for fixed mounting, size 3


Black handle, shaft 250 mm

3KX3 176-1E

1 unit

103

0.285

Extension shaft 300 mm long

8UC60 33

1 unit

103

0.217

Extension shaft 600 mm long

8UC60 83

1 unit

103

0.430

Shaft connecting pieces

8UC60 23

1 unit

103

0.085

3KX3 176-1E

Auxiliary switches
1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

1 NO + 1 NC, 20 ms leading

3KX3 552-3EA01

1 unit

103

0.019

Fuse monitor connections


(1 set = 6 units)

3KX3 505-0AA

1 unit

103

0.014

3SB14 00-0A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/49

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Accessories
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3KL61/3KL62
Terminal covers
For 3-pole devices (1set = 6 units)
For 4-pole devices (1set = 8 units)

}
B

3KX3 561-3DA01
3KX3 561-3DB01

1
1

1 unit
1 unit

103
103

0.263
0.365

Fuse covers
Cover plate
Complete covers1)

A
A

3KX3 561-0AA00
3KX3 561-1AA00

1
1

1 unit
1 unit

113
113

0.408
0.408

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm

8UC74 14-1BB44
+
8UC92 53

1 unit

103

0.200

1 unit

103

0.115

1 unit

103

0.200

8UC74 24-3BB44
+
8UC92 53

1 unit

103

0.115

Operating mechanisms for fixed mounting, size 5


Black handle, shaft 250 mm

3KX3 616-1A

1 unit

103

0.490

Extension shaft 300 mm long

8UC60 34

1 unit

103

0.315

Extension shaft 600 mm long

8UC60 84

1 unit

103

0.640

Shaft connecting pieces

8UC60 24

1 unit

103

0.077

3KX3 612-1B

1 unit

113

0.201

8UC92 53

}
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

Auxiliary switches2)
1 NO + 1 NC
1)

2)

Only for NH fuse systems.

For more 3SB34 00-0. contact blocks with other contact types, see
catalog IC 10, chapter 10 "Pushbutton Units and Indicator Lights".

SITOR fuses for 3KL and KM fuse switch disconnectors: Assignment table
For switch disconnectors
Type 3KL
Permissible
(Type 3KM) load current1)

Order No.

SITOR fuses
Required
conductor
crosssection
Cu

Size

Operational
class

mm 2

Rated Rated DT
current voltage

Price
per PU

PU
PS*/
(UNIT, P. unit
SET, M)

PG

Weight
per PU
approx.

kg

SITOR 3NE1 fuses for 3KL5, 3KL6 and 3 KM5


3KL50 30
16
(3KM50 30) 20
25
35
40
50
63

1.5
2.5
4
6
10
10
16

000 1)
000 1)
000 1)
000 1)
000 1)
000 1)
000 1)

gR/gS
gR/gS
gR/gS
gR/gS
gR/gS
gR/gS
gR/gS

16
20
25
35
40
50
63

690
690
690
690
690
690
690

}
}
}
}
}
}
}

3NE1 813-0
3NE1 814-0
3NE1 815-0
3NE1 803-0
3NE1 802-0
3NE1 817-0
3NE1 818-0

1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047

0.133
0.124
0.127
0.128
0.126
0.129
0.126

3KL52 30
80
(3KM52 30) 100
125
125

25
35
50
50

000 1)
00
00
00

gR/gS
gR/gS
gR/gS
gR

80
100
125
125

690
690
690
690

}
}
}
A

3NE1 820-0
3NE1 021-0
3NE1 022-0
3NE1 022-2

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.124
0.204
0.195
0.195

3KL55 30 160
(3KM55 30) 160
200
200
250
245

70
70
95
95
120
120

1
1
1
1
1
1

gR/gS
gR
gR/gS
gR
gR/gS
gR

160
160
200
200
250
250

690
690
690
690
690
690

}
A
}
A
}
A

3NE1 224-0
3NE1 224-2
3NE1 225-0
3NE1 225-2
3NE1 227-0
3NE1 227-2

1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047

0.522
0.535
0.518
0.508
0.515
0.533

3KL57 30 315
(3KM57 30) 280

2 70
2 70

1
1

gR/gS
gR

315
315

690
690

A
A

3NE1 230-0
3NE1 230-2

1 3 units
1 3 units

047
047

0.519
0.519

3KL57
350 (330)2)
3KL61 30 350 (300)2)
(3KM57 30) 400 (375) 2)

2 95
2 95
2 95

2
2
2

gR/gS
gR
gR/gS

350
400
400

690
690
690

}
A
}

3NE1 331-0
3NE1 331-2
3NE1 332-0

1 3 units
1 3 units
1 3 units

047
047
047

0.687
0.684
0.519

3KL61 30 450 (400) 2)


(3KM57 30) 450 (325) 2)
500 (400) 2)
500 (350) 2)

2 120
2 120
2 120
2 120

2
2
2
2

gR/gS
gR
gR/gS
gR

450
450
500
500

690
690
690
690

A
A
A
A

3NE1 333-0
3NE1 333-2
3NE1 334-0
3NE1 334-2

1
1
1
1

047
047
047
047

0.689
0.691
0.765
0.695

1)

Permissible load current in the switch disconnector.


In the case of cyclic loads, the currents may have to be reduced again
(precise values on request).

2)

Values in blue in brackets apply to 3KM switch disconnectors.

3 units
3 units
3 units
3 units

* You can order this quantity or a multiple thereof.

7/50

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KL Switch Disconnectors with Fuses up to 800 A
Accessories
For switch disconnectors
Type 3KL Permissible
(Type 3KM) load current1)

3KL61 30
(3KL62)

Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

3NE1 437-0
3NE1 437-1
3NE1 437-2
3NE1 438-0
3NE1 438-1
3NE1 438-2

1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047

1.045
1.179
1.031
1.560
1.100
1.067

A
A

3NE1 447-2
3NE1 448-2

1
1

3 units
3 units

047
047

1.044
1.048

SITOR fuses
Required
conductor
crosssection
Cu

Size

Operational
class

3
3
3
3
3

gR/gS
gR
gR
gR/gS
gR
gR
gR
gR

mm 2

630 (710)3)
630 (710)3)
630 (700)3)
630 (800)3)
630 (800)3)
630 (760)3)

2 x (40 x 5)
2 x (40 x 5)
2 x (40 x 5)
2 x (50 x 5)
2 x (50 x 5)
2 x (50 x 5)

630 (670)3)
630 (790)3)

2 x (40 x 5) 3
2 x (40 x 8) 3

Rated
current

Rated
voltage

DT

710
710
710
800
800
800

690
600
690
690
600
690

A
D
B
A
B
A

670
850

690
690

Price
per PU

kg

SITOR fuses 3NE3 ... 3NE8, 3NC2 for 3KL5, 3KL6 and 3KM5
3KL50
(3KM50)

25
33
45
54

4
6
10
16

00
00
00
00

gR
gR
gR
gR

25
35
50
63

690
690
690
690

}
}
}
}

3NE8 015-1
3NE8 003-1
3NE8 017-1
3NE8 018-1

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.193
0.195
0.614
0.196

3KL52
(3KM52)

68
89
106
130

25
35
50
70

00
00
00
00

aR
aR
aR
aR

80
100
125
160

690
690
690
690

}
}
}
}

3NE8 020-1
3NE8 021-1
3NE8 022-1
3NE8 024-1

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.206
0.207
0.195
0.195

32
40
50
63

6
10
10
16

0
0
0
0

gR
gR
gR
gR

32
40
50
63

1000
1000
1000
1000

}
}
}
}

3NE4 101
3NE4 102
3NE4 117
3NE4 118

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.824
0.258
0.274
0.257

80
95
120
150

25
35
50
70

0
0
0
0

aR
aR
aR
aR

80
100
125
160

1000
1000
1000
1000

}
}
}
}

3NE4 120
3NE4 121
3NE4 122
3NE4 124

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.261
0.260
0.265
0.274

90
110
140
175
210

35
50
70
95
120

1
1
1
1
1

aR
aR
aR
aR
aR

100
125
160
200
250

1000
1000
1000
1000
1000

A
A
}
}
}

3NE3 221
3NE3 222
3NE3 224
3NE3 225
3NE3 227

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

0.510
0.506
0.513
0.586
0.580

3KL57
(3KM57)

240
265
290
320

185
240
240
2 150

1
1
1
1

aR
aR
aR
aR

315
350
400
450

1000
1000
1000
1000

}
A
A
}

3NE3 230-0B
3NE3 231
3NE3 232-0B
3NE3 233

1
1
1
1

3 units
3 units
3 units
3 units

047
047
047
047

0.513
0.515
0.520
0.580

3KL61
(3KL62)
(3KM57)

340 (360)3) (290)4)


380 (400)3) (320) 4)
440 (470)3) (360)4)
500 (530)3) (400)4)
540 (580)3) (400)4)

240
2 150
2 150
2 185
2 185

2
2
2
2
2

aR
aR
aR
aR
aR

400
450
500
560
630

1000
1000
1000
1000
1000

A
A
}
}
}

3NE3 332-0B
3NE3 333
3NE3 334-0B
3NE3 335
3NE3 336

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

0.683
0.687
0.697
0.692
0.810

600 (640)3) (400)4)


630 (720)3) (400)4)
630 (800)3) (400)4)

2 200
2 200
2 200

2
2
2

aR
aR
aR

710
800
900

900
800
690

3NE3 337-8
3NE3 338-8
3NE3 340-8

1
1
1

3 units
3 units
3 units

047
047
047

0.687
0.686
0.657

200 (200)3) (175)4)


260 (260)3) (230)4)
370 (370)3) (340)4)
425 (450)3) (380)4)
600 (630)3) (400)4)

120
240
2 x (30 x 5)
2 x (30 x 5)
2 x (40 x 5)

2
2
2
2
2

aR
aR
aR
aR
aR

250
315
450
500
710

800
800
800
800
800

}
}
}
}
}
}
}
}

3NE4 327-0B
3NE4 330-0B
3NE4 333-0B
3NE4 334-0B
3NE4 337

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

0.780
1.539
0.682
0.683
0.689

145 (150)3)
180 (190)3)
225 (240)3)
255 (270)3)
330 (345)3)
400 (400)3)

70
95
120
185
240
240

3
3
3
3
3
3

gR
gR
gR
gR
gR
gR

150
200
250
300
350
400

500
500
500
500
500
500

B
B
B
B
B
B

3NC2 423-3C
3NC2 425-3C
3NC2 427-3C
3NC2 428-3C
3NC2 431-3C
3NC2 432-3C

1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047

0.940
0.940
0.940
0.940
0.940
0.940

135 (140)3)
180 (190)3)
225 (240)3)
300 (315)3)
425 (450)3)

70
95
120
240
2 150

3
3
3
3
3

gR
gR
gR
gR
gR

150
200
250
350
500

660
660
660
660
660

B
B
B
B
B

3NC8 423-3C
3NC8 425-3C
3NC8 427-3C
3NC8 431-3C
3NC8 434-3C

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

0.940
0.940
0.940
0.940
0.940

630 (800)3)

2 (60 x 6) 3

aR

1000

600

3NC8 444-3C

3 units

047

0.940

3KL552)
(3KM55)2)

3KL61
(3KL62)

1)

Permissible load current in the switch disconnector.


In the case of cyclic loads, the currents may have to be reduced again
(precise values on request).

2)

Due to the mechanical stress on the relatively long fuse blades,


SITOR 3NE4 1 fuses should be switchable only occasionally and
only at zero current.

3)

Values in black in brackets apply to 3KL62 switch disconnectors.

4)

Values in blue in brackets apply to 3KM switch disconnectors.

For technical specifications and dimensional drawings of the


SITOR fuses, see chapter 5 "Fuse Systems"

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/51

Siemens AG 2011

Switch Disconnectors
SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
Introduction

Overview

NSE0_01557b

7
1
4

9
8
3
3KL or 3KM basic device
Plug-in contact strip for 3KM
3

Fuses, optionally BS-88 or LV HRC fuses


Terminal cover, IP20 (vertical to operator side)
Coupling driver with extension shaft

Optional
8UC9 knob for fixed mounting in standard version (black) or
EMERGENCY-STOP version (red), or
9 8UC7 door-coupling rotary operating mechanism in standard
version (ti-grey) or EMERGENCY-STOP version (red/yellow)

Standard products from the Siemens 3SB1 range


are used as auxiliary switches.
Single-pole terminal cover from 63 A to 630 A, IP20
(vertical to operator side)

All components from the switch to the actuator are provided with
non-interchangeability features.

All switch disconnectors feature double contact interruption and


an isolating distance. As a result, the fuses are de-energized
when the switch disconnectors are in the disconnected position.
The 3KM switch disconnectors with fuses also feature an isolating plug connector. This facilitates mounting and contact establishment in motor control centers (MCCs) in conjunction with vertical busbars. Generally all 3K.5 switch disconnectors can can

be secured to the shaft with padlock against unauthorized reclosing.


Identical accessories for 3KA switch disconnectors and for 3KL
and 3KM switch disconnectors with fuses simplify stock keeping. Please inquire about a special variant with reduced values
that is particularly resistant to atmospheres high in sulfur, e. g. in
the paper and cellulose processing industries.

Application
3KM switch disconnectors with fuses protect against overload
and short-circuits as main and EMERGENCY-STOP switches of
switch boards, distribution boards, power supply and motor outgoing feeders. In conjunction with Siemens SITOR semiconductor fuses, they are also used in UPS systems, frequency
converters and capacitor control systems.

7/52

Siemens LV 10.1 2011

All 3K switch disconnectors are climate-proof and meet the


requirements of IEC 60947-1 and IEC 60947-3.

Siemens AG 2011

Switch Disconnectors
SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
Introduction

Technical specifications
Standards

IEC 60947-1, IEC 60947-3


3KM50

3KM52

3KM53

3KM55

3KM57

Rated uninterrupted current Iu


For fuse links acc. to DIN 43620,
(when SITOR semiconductor fuses are used,
a reduction of rated current is necessary,
see reference to technical information at start of chapter)

A
Size

63
00 and 000

125
00 and 000

160
00 and 000

250
1 and 2

400
1 and 2

Conventional free-air thermal current Ith1)

63

125

160

250

400

Rated insulation voltage Ui

690

1000

1000

1000

1000

Rated impulse withstand voltage Uimp

kV

Type

Rated operational voltage Ue


50/60 Hz AC

690

DC

V
V

440 (3 conducting paths series-connected)


220 (2 conducting paths series-connected) 2)

Rated short-circuit making capacity with fuses


(peak value, at 50/60 Hz 690 V AC)

kA

220

220

220

176

176

Rated conditional short-circuit current with fuses


At 50/60 Hz 690 V AC (rms value)

kA

100

100

100

80

80

Max. rated current In of the fuses

80

160

160

400

400

Max. permissible power loss of the installed fuse


NH

11.5

32

45

BS

8 (A2/A3)

11.5 (A4)

11.5

32

45

Permissible let-through current of the fuses

kA

17

17

303)

303)

Maximum permissible let-through I2t value

kA2s

55

223

223

1000

1000

Switching capacity (infeed from the top or bottom)


At 400 V AC
Breaking current Ic (at p.f. = 0.35, rms)

500

1000

1280

2000

3200

Rated operational current Ie with AC-21A, AC-22A, AC-23A

63

125

160

250

400

Motor switching capacity AC-23A

kW

30

65

80

132

200

At 500 V AC
Breaking current Ic (at p.f. = 0.35, rms)

500

1000

1280

2000

3200

Rated operational current Ie with AC-21A, AC-22A, AC-23A

63

125

160

250

400

Motor switching capacity AC-23A

kW

40

90

110

185

280

At 690 V AC
Breaking current Ic (at p.f. = 0.35, rms)

500

1000

1280

2000

3200

Rated operational current Ie with AC-21A, AC-22A, AC-23A

63

125

160

250

400

Motor switching capacity AC-23A

kW

50

110

150

220

375

At 440 V DC (3 conducting paths series-connected)4)


Breaking current Ic (L/R = 15 ms)

250

500

640

10004)

1600

Rated operational current Ie at DC-23A

63

125

160

2505)

400

Rated short-time current (1 s current), rms value

kA

2.5

3.2

3.2

11

Permissible ambient temperature

C
C

-25 ... +55 for operation6)


-50 ... +80 when stored
15000

12000

12000

Mechanical endurance, operating cycles

15000

Degree of protection

IP00/IP20 (from the operator side, with fuse and terminal covers)

15000

8.5

22

36

33

86

Busbar systems, max. dimensions (w t)

mm

25 9

45 10

45 10

40 12

40 15

Cable lug, max. conductor cross-section (stranded)

mm2

35

70

120

150

2 150 or
1 240

Busbar systems, max. dimensions (w t)

mm

25 9

45 10

45 10

40 12

40 15

Tightening torque

Nm

6 ... 7.5

7 ... 10

18 ... 22

35 ... 45

35 ... 45

M6

M6

M8

M10

M10

Power loss of the switch disconnector at Ith


(plus power loss of the fuses)
Main conductor connections

Terminal screws
Protective conductor connections
Flat bars

mm

--

--

--

20 2.5

20 2.5

Cable lug, max. conductor cross-section (stranded)

mm2

--

--

--

70

120

1)

Configuring note: Max. permissible operating temperature for fuse blades


135 C, for connections 100 C.

2)

110 V (one conducting path).

3)

220 V DC (L1 and L3 series-connected) or 110 V DC


(one conducting path) at DC-23A.

4)

At 440 V L/R = 4 ms, at 220 V L/R = 15 ms.

5)

At 440 V DC-22A, at 220 V DC-23A.

6)

3ND1 switchgear protection fuse.

Siemens LV 10.1 2011

7/53

Siemens AG 2011

Switch Disconnectors
SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
For snapping onto busbars

Selection and ordering data


All switch disconnectors with degree of protection IP00
Mounting on vertical busbars with busbar center-to-center spacing of 60 mm and bar thickness from 5 mm to 6.35 mm
Conductor connecting screws and fuse partitions are generally included in the scope of supply.
Rated uninterrupted
current Iu

LV HRC fuse links1) acc. to


DIN 436202)

Size

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Operational
class

kg

Complete versions with 8UC7 door-coupling rotary operating


mechanisms
3-pole for NH fuse systems
(black handle)

63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
B

3KM50 30-1GB01
3KM52 30-1GB01
3KM53 30-1GB01

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.890
2.860
2.935

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

3KM55 30-1GB01
3KM57 30-1GB01

1
1

1 unit
1 unit

103
103

5.670
6.938

3-pole for fuses acc. to BS 88


Complete versions with 8UC7 door-coupling rotary
operating mechanism (black handle)
125

Form A2/A3

3KM52 30-1GG01

1 unit

103

2.785

125
160

Form A4
Form A4

C
C

3KM52 30-1GJ01
3KM53 30-1GJ01

1
1

1 unit
1 unit

103
103

2.340
2.926

250
400

Form B1-B3
Form B1-B3

C
C

3KM55 30-1GG01
3KM57 30-1GG01

1
1

1 unit
1 unit

103
103

6.651
7.175

Basic switch versions without handle


3-pole for NH fuse systems
63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
C

3KM50 30-1AB01
3KM52 30-1AB01
3KM53 30-1AB01

1
1
1

1 unit
1 unit
1 unit

103
103
103

1.515
2.450
2.516

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

3KM55 30-1AB01
3KM57 30-1AB01

1
1

1 unit
1 unit

103
103

5.698
5.966

3KM53 30-1AB01
with fuses
3-pole for fuses acc. to BS 88
63
125

Form A2/A3
Form A2/A3

C
C

3KM50 30-1AG01
3KM52 30-1AG01

1
1

1 unit
1 unit

103
103

1.450
2.405

125
160

Form A4
Form A4

C
C

3KM52 30-1AJ01
3KM53 30-1AJ01

1
1

1 unit
1 unit

103
103

2.430
2.520

250
400

Form B1-B3
Form B1-B3

C
C

3KM55 30-1AG01
3KM57 30-1AG01

1
1

1 unit
1 unit

103
103

5.689
6.250

3KM55 30-1AG01
with fuses

8UC7 EMERGENCY-STOP door-coupling rotary operating mechanisms


(red handle, yellow indicator plate)
for basic switch versions without handle

8UC71 21-3BB10

63
125
160

00 and 000
00 and 000
00 and 000

gG, aM
gG, aM
gG, aM

B
B
B

8UC71 21-3BB10
8UC72 22-3BB20
8UC72 22-3BB20

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.200
0.200
0.200

250
400

1 and 2
2 and 1

gG, aM
gG, aM

B
B

8UC73 23-3BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

8UC7 EMERGENCY-STOP door-coupling rotary operating


mechanisms (red handle, yellow indicator plate)
63
125

Form A2/A3
Form A2/A3

B
B

8UC71 21-3BB10
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

125
160

Form A4
Form A4

B
B

8UC72 22-3BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

250
400

Form B1-B3
Form B1-B3

B
B

8UC73 23-3BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

Fuse monitoring through 5TT3170 safety monitor with a floating


1 NO signaling contact, see chapter 5 "Fuse Systems".
1)

Silver-plated fuse blades. Silver-plated isolating links can be used if


desired.

2)

For the assignment of semiconductor fuses see "3KL Switch Disconnectors


with Fuses up to 800 A" --> "Accessories".
* You can order this quantity or a multiple thereof.

7/54

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
Accessories

Selection and ordering data


Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3KM50
Terminal covers
For 3-pole devices (1set = 6 units)

3KX3 552-3DA01

1 unit

103

0.077

Fuse covers
(interlock only detachable in the OFF position)

3KX3 517-3AA

1 unit

103

0.041

Fuse partitions
(1 set = 5 units)

3KX3 507-0AA01

1 unit

103

0.044

Lyre-shaped fuse covers


(1 set = 6 units)

3KX3 507-0BA01

1 unit

103

0.033

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm
C
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

8UC71 11-1BB10
8UC71 21-3BB10

1
1

1 unit
1 unit

103
103

0.200
0.200

3KX3 5.7-3AA

3KX3 507-0BA01

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm

3KX3 516-1AA

1 unit

103

0.088

Extension shaft 300 mm long

8UC60 31

1 unit

103

0.068

Extension shaft 600 mm long

8UC60 81

1 unit

103

0.136

Shaft connecting pieces

8UC60 21

1 unit

103

0.031

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

Fuse monitor connections


(1 set = 6 units)

3KX3 505-0AA

1 unit

103

0.014

}
}
B
B

3KX3 552-3DA01
3KX3 553-3DA01
3KX3 552-3DB01
3KX3 553-3DB01

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.077
0.147
0.102
0.170

Fuse covers1)
(interlock only detachable in the OFF position)

3KX3 527-3AA

1 unit

103

0.071

Fuse partitions
(1 set = 5 units)

3KX3 507-0AA01

1 unit

103

0.044

Lyre-shaped fuse covers


(1 set = 6 units)

3KX3 507-0BA01

1 unit

103

0.033

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm
C
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

8UC72 12-1BB20
8UC72 22-3BB20

1
1

1 unit
1 unit

103
103

0.200
0.200

3KX3 536-1AA

1 unit

103

0.155

Auxiliary switches

3SB14 00-0A

3KM52/3KM53
Terminal covers
For 3-pole devices (1set = 6 units)
For 4-pole devices (1set = 8 units)

3KM52
3KM53
3KM52
3KM53

3KX3 5.7-3AA

3KX3 507-0BA01

Operating mechanisms for fixed mounting


Black handle, shaft 250 mm
1)

For 3KX3 527-3AA: Not suitable for use with type A4 BS fuses.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/55

Siemens AG 2011

Switch Disconnectors
SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
Accessories
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Extension shaft 300 mm long

8UC60 32

1 unit

103

0.132

Extension shaft 600 mm long

8UC60 82

1 unit

103

0.265

Shaft connecting pieces

8UC60 22

1 unit

103

0.023

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

1 NO + 1 NC, 20 ms leading

3KX3 552-3EA01

1 unit

103

0.019

Fuse monitor connections


(1 set = 6 units)

3KX3 505-0AA

1 unit

103

0.014

}
B

3KX3 557-3DA01
3KX3 557-3DB01

1
1

1 unit
1 unit

103
103

0.277
0.362

Fuse covers
(interlock only detachable in the OFF position)

3KX3 557-3AA

1 unit

103

0.212

Fuse partitions
(1 set = 5 units)

3KX3 557-0AA01

1 unit

103

0.162

Door-coupling rotary operating mechanisms IP65


Black handle, shaft 300 mm
C
EMERGENCY-STOP (yellow/red), square shaft 300 mm B

8UC73 13-1BB30
8UC73 23-3BB30

1
1

1 unit
1 unit

103
103

0.200
0.200

kg

Auxiliary switches

3SB14 00-0A

3KM55/3KM57
Terminal covers
For 3-pole devices (1set = 6 units)
For 4-pole devices (1set = 8 units)

3KX3 5.7-3AA

3KX3 557-0AA01

Operating mechanisms for fixed mounting, size 3


Black handle, shaft 250 mm

3KX3 176-1E

1 unit

103

0.285

Extension shaft 300 mm long

8UC60 33

1 unit

103

0.217

Extension shaft 600 mm long

8UC60 83

1 unit

103

0.430

Shaft connecting pieces

8UC60 23

1 unit

103

0.085

1 NO + 1 NC

3SB14 00-0A

1 unit

102

0.020

2 NO

3SB14 00-0G

1 unit

102

0.020

2 NC

3SB14 00-0H

1 unit

102

0.020

1 NO + 1 NC, 20 ms leading

3KX3 552-3EA01

1 unit

103

0.019

Fuse monitor connections


(1 set = 6 units)

3KX3 505-0AA

1 unit

103

0.014

3KX3 176-1E

Auxiliary switches

3SB14 00-0A

* You can order this quantity or a multiple thereof.

7/56

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
For 3K switch disconnectors

Overview
Available sizes
Rotary
operating
mechanisms

Size

Rated
torque1)

Shaft profile

Masking plate

8UC71

Nm

mm x mm

mm x mm

6x6

8UC72

75 x 75

8x8

75 x 75

8UC73

25

10 x 10 or 12 x 12

100 x 100

8UC74

40/552)

12 x 12

100 x 100

1)

Operating mechanisms tested with triple torque (according to


EN 60947-3). They are therefore also suitable for applications in this area.

2)

Operation with two hands.

Degree of protection

Degree of protection when installed is IP65.


Standards
8UC7 door-coupling rotary operating mechanisms are in line
with for example the following standards:
8UC7 rotary operating mechanism in STANDARD version (left) and
EMERGENCY-STOP version (right)

With door-coupling rotary operating mechanisms it is also possible to operate switch disconnectors from the outside with the
control cabinet doors closed
The rotary operating mechanisms are available in "STANDARD"
and "EMERGENCY-STOP" versions with the following differences:
STANDARD version: Masking plates in light-gray with black
inscription, handles in ti-grey.
EMERGENCY-STOP version: Masking plates in yellow with
black inscription, handles in red.

Standard

Title

IEC 60204-1, EN 60204-1

Safety of machinery; Electrical equipment


of machines

IEC 60439-1, EN 60439-1

Low-voltage switchgear and controlgear


assemblies

IEC 60947-3, EN 60947-3

Low-voltage switchgear and controlgear;


Switches, disconnectors, switch disconnectors and fuse-combination units

Siemens LV 10.1 2011

7/57

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
For 3K switch disconnectors

Benefits

Application

Can be locked
The retractable locking device integrated in the handles is suitable for padlocks with shackle diameters of 4.5 mm to 8.5 mm
(locks according to DIN 7465).
Up to three padlocks with a shackle diameter of 8.5 mm and up
to five padlocks with a shackle diameter of 6 mm can be fitted
simultaneously.
Non-interchangeability
In order to ensure that, when installing switches and door-coupling operating mechanisms, all components are assembled in
the correct position with respect to one another, the components
are provided with non-interchangeability features (rivel and lug).
Stops

Stops are used to prevent damage occuring as the result of excessive torque. These stops are supplied loose with the rotary
operating mechanisms and can be fitted as required. Stops are
fitted at the factory to size 1 and 2 rotary operating mechanisms
with a 90 operating angle (exception: 3RV motor starter protectors/circuit breakers).
Tolerance compensation
8UC7 rotary operating mechanisms are capable of taking up a
radial eccentricity of max. 3 mm between the actuating shaft of
the switching device and the door-coupling rotary operating
mechanism. Supporting the extension shaft is recommended
with greater tolerances.

NS

E0

_0

09

45

Coupling
drivers

With tolerance +3
compensation

Shaft
length

Without
+1.5 2.5 x+23.5
tolerance
compensation

Permissible radial eccentricity and axial tolerance compensation in mm

Pull-out strength
The pull-out strength of interlocked operating mechanisms, e.g. pulling
off the shaft or destruction of the operating mechanism, amounts to 800 N
when the pulling force acts directly onto the operating mechanism in direction of shaft.

7/58

Siemens LV 10.1 2011

8UC7 door-coupling rotary operating mechanisms can be used


in electrical controls, distribution boards and switchboards in
cases where switches have to be mounted behind covers, end
plates and doors that must be opened and where they are to be
operated manually from outside.
Interlocking conditions
The basic versions of the rotary operating mechanisms comply
with the following interlocking conditions:
Operating mechanism and switch in "0" (OFF) position:
The control cabinet door can be opened. With padlocks fitted,
the control cabinet door remains locked however.
Operating mechanism and switch in "I" (ON) position:
The control cabinet door cannot be opened in this position.
However, the interlock can be overridden and the control cabinet door opened by trained personnel for performing checks.
No padlocks can be fitted in "I" position.
Other interlocking conditions:
If no door interlock is required, the user can remove the door
interlocking plate of the rotary operating mechanism.
It is easy for the user to fit padlocks to the rotary operating
mechanisms in the "I" position as well. In this case the door
cannot be opened, the operating mechanism cannot be actuated and the door interlock cannot be overridden.
Operating conditions and ambient conditions
The temperature range for operation of the rotary operating
mechanisms is between -25 C and +60 C.
Thanks to the use of glass fiber-reinforced molded plastic for
handles and masking plates as well as metal components with
surface protection, the rotary operating mechanisms are suitable for rough conditions, high air humidity and aggressive atmospheres.

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
For 3K switch disconnectors

Design
Components

Switch position

The rotary operating mechanisms consist of a masking plate


with handle, including seal and fixing screws for door installation, an extension shaft (300 mm) and a coupling driver to be
mounted onto the switch shaft.

In order to ensure compliance with locking and interlocking conditions, the controls and operating mechanisms must be installed such that, with two-position switches the "0" position lies
at 9 o'clock and the "I" position at 12 o'clock.

Operating mechanisms for 3KA / 3KL / 3KM switch disconnectors do not have a shaft coupling since the extension shaft is fitted directly into the switch. Extension shafts with a length of
600 mm are also available.

1
90

0
2
7

NSE0_00352a

1 12 o'clock position
2

9 o'clock position

4
3

Positions for two-position switches with 90 operating angle

2
10
1
8

NSE0_00022a

Handle with masking frame

Seal

Door

Fixing screws

Coupling driver

Extension shaft

Adapter

Operating shaft of switching device

Switching device

10

Tripped plate (can be glued on if required)

Design, schematic representation

Siemens LV 10.1 2011

7/59

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
For 3K switch disconnectors

Selection and ordering data


Door-coupling rotary operating mechanisms, fully lockable with padlocks,
with door interlock supplied with seal and fixing screws
Switching device Rated current Cross-section of Torque
the actuating
shaft

Rotary
Illustrated: Handle,
operating
masking plate
mechanisms

Type

Nm

Size

mm

8UC71
For switch disconnectors with or without fuses
6x6
6x6

3
3

80

6x6

3KA511)

NSE00355

75

3KL501), 3KM501) 63
63
3KA501)

36

8UC72
For switch disconnectors with or without fuses
3KL52, 3KM52

125

3KL53, 3KM53
3KA52
3KA53

75

8x8

7.5

160

8x8

7.5

125

8x8

7.5

160

8x8

7.5

2
NSE00356

62

8UC73
For switch disconnectors with or without fuses

100

250

10 x 10

16

3KL57, 3KM57

400

10 x 10

16

3KA55

250

10 x 10

16

3KA57
3KA58

400
630

10 x 10
10 x 10

16
16

3
NSE00357

3KL55, 3KM55

140

For switch disconnectors without fuses

100

250

12 x 12

15

3KE43

400

12 x 12

15

3KE44

630

12 x 12

24

3KE45

1000

12 x 12

24

3
NSE00357

3KE42

140

8UC74
For switch disconnectors with fuses

100

630

12 x 12

30

3KL622)

800

12 x 12

30

4
NSE00358

3KL612)

200

For switch disconnectors as changeover switches with break-before-make


feature
250

12 x 12

20

3KE43 (2 units)

400

12 x 12

20

3KE44 (2 units)

630

12 x 12

30

3KE45 (2 units)

1000

12 x 12

30

NSE0_01892

3KE42 (2 units)

100

200

For switch disconnectors as changeover switches without break-beforemake feature


250

12 x 12

40

3KE43 (2 units)

400

12 x 12

40

3KE44 (2 units)

630

12 x 12

55

3KE45 (2 units)

1000

12 x 12

55

100

3KE42 (2 units)

200

NSE0_01891

For load disconnect switch as parallel connection

1)

2)

250

12 x 12

40

3KE43 (2 units)

400

12 x 12

40

3KE44 (2 units)

630

12 x 12

55

3KE45 (2 units)

1000

12 x 12

55

Valid only for 3-pole switching devices. For 4-pole switching devices, an
operating mechanism with 8 x 8 mm actuating shaft must be used,
see lower level for 3KA52, 3KL52 or 3KM52.

100

4
NSE00358

3KE42 (2 units)

200

3)

The door interlocking plate must be removed.

4)

With shortened 8UC60 16/8UC60 17 coupling driver and reduced tolerance compensation, see "Dimensional Drawings".

Additionally required for 3KL61: 1 shaft coupling, order no. 8UC92 53,
see individual parts, table, page 7/62.

* You can order this quantity or a multiple thereof.

7/60

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
For 3K switch disconnectors

Individual parts
Version

DT

Rotary operating mechanisms,


complete
Order No.

Standard

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Price
per PU

Weight Handle with


per PU masking plate
approx.
Order No.

Coupling
drivers

Extension shaft
Length 300 mm

Shaft couplings

Order No.

Order No.

Order No.

kg
@ 6 mm

@ 6 mm

@ 6 mm by 6 mm

8UC60 11

8UC60 31

Not required

8UC71 11-1BB10

1 unit

103

0.200 8UC71 10-1BB

Standard4) C

8UC71 61-1BB10

1 unit

103

0.200 8UC71 10-1BB

8UC60 16

8UC60 31

Not required

EMERGENCYSTOP

8UC71 21-3BB10

1 unit

103

0.200 8UC71 20-3BB

8UC60 11

8UC60 31

Not required

@ 8 mm

@ 8 mm

@ 8 mm by 8 mm

Standard

8UC72 12-1BB20

1 unit

103

0.200 8UC72 10-1BB

8UC60 12

8UC60 32

Not required

Standard4) C

8UC72 62-1BB20

1 unit

103

0.200 8UC72 10-1BB

8UC60 17

8UC60 32

Not required

EMERGENCYSTOP

8UC72 22-3BB20

1 unit

103

0.200 8UC72 20-3BB

8UC60 12

8UC60 32

Not required

@ 10 mm

@ 10 mm

@ 10 mm by 10 mm

Standard

8UC73 13-1BB30

1 unit

103

0.200 8UC73 10-1BB

8UC60 13

8UC60 33

Not required

EMERGENCYSTOP

8UC73 23-3BB30

1 unit

103

0.200 8UC73 20-3BB

8UC60 13

8UC60 33

Not required

@ 12 mm

@ 12 mm

@ 12 mm by 12 mm

Standard

8UC73 14-1BB44

1 unit

103

0.200 8UC73 10-1BB

8UC60 14

8UC60 34

8UC60 24

EMERGENCYSTOP

8UC73 24-3BB44

1 unit

103

0.200 8UC73 20-3BB

8UC60 14

8UC60 34

8UC60 24

@ 12 mm

@ 12 mm

@ 12 mm by 12 mm

Standard

8UC74 14-1BB44

1 unit

103

0.200 8UC74 10-1BB

8UC60 14

8UC60 34

8UC60 24

EMERGENCYSTOP

8UC74 24-3BB44

1 unit

103

0.200 8UC74 20-3BB

8UC60 14

8UC60 34

8UC60 24

@ 12 mm

@ 12 mm

@ 12 mm by 12 mm

Standard

8UC74 14-1BF44

1 unit

103

0.200 8UC74 10-1BF

8UC60 14

8UC60 34

8UC60 24

@ 12 mm

@ 12 mm

@ 12 mm by 12 mm

Standard

8UC74 14-1FG44

1 unit

103

0.200 8UC74 10-1FG

8UC60 14

8UC60 34

8UC60 24

@ 12 mm

@ 12 mm

@ 12 mm by 12 mm

Standard

8UC74 14-1BB44

1 unit

103

0.200 8UC74 10-1BB

8UC60 14

8UC60 34

8UC60 24

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/61

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
Individual parts

Selection and ordering data


Switching
device

Type

Rotary
operating
mechanisms

Size

Crosssection
of the
actuating
shaft

Version4) DT

Individual parts for 8UC7


door-coupling rotary
operating mechanisms
Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Price
per PU

mm mm

Type

Weight
per PU
approx.

kg

Handles with masking plate (including flat gasket and fixing screws)
3KL50,
3KM50,
3KA50,
3KA51

8UC71

66

Standard C

8UC71 10-1BB

1 unit

103

0.200

EMERGENCYSTOP

8UC71 20-3BB

1 unit

103

0.200

Standard C

8UC72 10-1BB

1 unit

103

0.200

EMERGENCYSTOP

8UC72 20-3BB

1 unit

103

0.200

Standard C

8UC73 10-1BB

1 unit

103

0.200

EMERGENCYSTOP

8UC73 20-3BB

1 unit

103

0.200

Standard C

8UC74 10-1BB

1 unit

103

0.200

EMERGENCYSTOP

8UC74 20-3BB

1 unit

103

0.200

Standard C

8UC74 10-1BF

1 unit

103

0.200

Standard C

8UC74 10-1FG

1 unit

103

0.200

Standard C

8UC74 10-1BB

1 unit

103

0.200

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

8UC71

3KL52, 3KM52, 8UC72


3KL53, 3KM53,
3KA52, 3KA53

3KL55, 3KM55, 8UC73


3KL57, 3KM57,
3KA55, 3KA57,
3KE42, 3KE43,
3KE44, 3KE45

3KL61, 3KL62

88

8UC72
10 10
or
12 x 12

8UC73
8UC74

3KE42, 3KE43, 8UC743) 4


3KE44, 3KE45

8UC74

12 12

12 12

Rotary operating
mechanisms

Cross-section of the
actuating shaft

Type

mm mm

DT

Individual parts for 8UC6


door-coupling rotary
operating mechanisms
Order No.

Price
per PU

kg

Coupling drivers, extension shafts, shaft couplings and reducers


Coupling drivers for 3K

Rivet

nse0_00372

8UC60 11

8UC71
8UC712)
8UC72
8UC722)
8UC73
8UC73/74

66
66
88
88
10 10
12 12

B
A
B
A
B
B

8UC60 11
8UC60 16
8UC60 12
8UC60 17
8UC60 13
8UC60 14

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103
103

0.078
0.070
0.075
0.043
0.251
0.253

B
B
C
B

8UC60 31
8UC60 32
8UC60 33
8UC60 34

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.068
0.132
0.217
0.315

66
88
10 10
12 12

B
B
B
B

8UC60 81
8UC60 82
8UC60 83
8UC60 84

1 unit

103

0.136

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.265
0.430
0.640

66
88
10 10
12 12
12 12

B
B
B
B
}

8UC60 21
8UC60 22
8UC60 23
8UC60 24
8UC92 53

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

103
103
103
103
103

0.031
0.023
0.085
0.077
0.115

8 8 to 6 6
12 12 to 8 8

C
C

8UC70 58
8UC70 50

1
1

1 unit
1 unit

103
103

0.200
0.200

Extension shafts 300 mm long


8UC71
8UC72
8UC73
8UC73/74

NSE0_00373

Groove
8UC60 31 ... 34

66
88
10 10
12 12

Extension shafts 600 mm long


8UC71
8UC72
8UC73
8UC73/74

NSE0_00373

Groove
8UC60 81 ... 84

Shaft couplings

nse0_00374

Lug Rivet
8UC60 21 to 8UC6024

8UC71
8UC72
8UC73
8UC73/74
8UC74 (3KL61)
Reducers
8UC71
8UC72

ns

g0

2
00

44

8UC70 58

ns

g0

_0

02

45

8UC70 50

1)

Non-interchangeability features.

2)

Shortened coupling driver with reduced tolerance compensation.

3)

For switch disconnectors as changeover switches in various versions,


see table on page 7/60

4)

Standard: Ti-grey handle, light-gray masking plate;


EMERGENCY-STOP: Red handle, yellow masking plate.

* You can order this quantity or a multiple thereof.

7/62

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
8UC Door-Coupling Rotary Operating Mechanisms
Operating mechanisms for fixed mounting

Selection and ordering data

8UC93 54

Switching
device

Crosssection
of the
actuating
shaft

Torque
of the
operating
mechanism1)

Oper- Color of
ating
handle
mechanism

DT

Type

mm mm Nm

Size

3KA50,
3KA51,
3KL50,
3KM50

66

Black

2)

7.5

Black

2)

7.5

Black

Operating mechanisms for fixed


mounting

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

8UC93 54

1 unit

103

0.031

8UC93 60

1 unit

103

0.047

8UC93 62

1 unit

103

0.041

Order No.

Price
per PU

kg

8UC93 60

8UC93 65

3KA52
3KA53,
3KL52,
3KM52,
3KL53,
3KM53

88

3KL55,
3KM55,
3KL57,
3KM57

10 10

7
16

3KA55,
3KA57,
3KA58

Red

8UC93 63

1 unit

103

0.044

Black

8UC93 65

1 unit

103

0.138

Red

8UC93 66

1 unit

103

0.160

3KE42,
3KE43

12 12

16

Black

3)

8UC93 70

1 unit

103

0.128

Red

3)

8UC93 71

1 unit

103

0.146

3KE44,
3KE45

12 12

30

Black

3)

8UC93 74

1 unit

103

0.145

Red

3)

8UC93 75

1 unit

103

0.165

Black

8UC93 81

1 unit

103

0.264

Red

8UC93 82

1 unit

103

0.273

8UC93 74
3KL61

12 12

55

8UC93 81
1)

Operating mechanisms were tested with triple torque (EN 60947-3). They
are therefore qualified for use in all controls, especially for disconnectors.

2)

Red handle available on request.

3)

Also required: 3KX2 210-0H coupling socket.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/63

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
Introduction

Overview

All key product features at a glance


In-line
Type-tested according to IEC EN 60947-3
Voltage levels up to 690 V AC/440 V DC
160 A to 630 A for LV HRC and BS 88 fuse links, according to
IEC 60269-1/EN 60269-1
2-, 3- and 4-pole versions available
185 mm phase center distance of plug-in contacts
Manually operated or with motorized operating mechanism
Electronic fuse monitoring (EFM)
Developed for switchgears in plug-in design
Horizontal or vertical mounting position
Front panel locked in ON position
Degree of protection IP41
3NJ62 Switch Disconnectors with Fuses

Overview of components and accessory parts





























7/64

11

Connection terminals

12

Stud terminal

13

Terminal cover

Motor drive

14

Multifunction plug

Connection module

15

Holder for measuring device with electronic fuse monotoring (EFM10)

Blanking cover

16

Holder for measuring device with electronic fuse monotoring (EFM20/25)

Guide rails

17

Holder for measuring device without EFM

Busbar cover

18

Bimetal current measuring device

Contact extension

19

Moving-iron current measuring device

Current transformer

20

BS fuse

10 Current transformer bar

21

NH fuse

22

Auxiliary switch

3NJ62 switch disconnector basic device


here in size 00, open, without front cover

Hand drive

Siemens LV 10.1 2011

,B

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
Introduction

Benefits
Key advantages for switchgear manufacturers due to the
following:
Compact, modular design
Simple and efficient mounting due to incoming plug-in contact
High packing density in the field
Cable connection with cable clamps or cable lugs
Can be mounted in different control cabinet depths
Comprehensive range of accessories
The advantages for users are:
Conversion, retrofitting and replacement without switching off
the switchgear
Dead-state fuse replacement
Maintenance free
High personal safety
Operating handle can be locked in OFF position
Clear and unambiguous switch position indicator

Application

Function
Fuse monitoring
Fuse monitoring is used to detect, indicate and report faults.
The electronic fuse monitors are available in 2 versions.
EFM10 electronic fuse monitor:
For use up to 690 V AC
Operational voltage < 20 V
Display: ready-to-run
Individual fault display per phase
1 CO contact as centralized fault signaling unit
EFM20/25 electronic fuse monitor and line monitor:
EFM20 for use up to 690 V AC, EFM25 for use up to 440 V DC
Operational voltage < 13 V (EFM20) < 20 V (EFM25)
Test function
Closed-circuit principle or open-circuit principle
2 CO contacts as centralized fault signaling unit incl. line monitoring functions with phase failure detection (EFM20), undervoltage/overvoltage detection

The plug-in 3NJ6 switch disconnectors with fuses are installed


in low-voltage distribution boards where a minimum amount of
space is available for a maximum number of cable ducts to the
power distribution. They can be easily fitted in all common control cabinets (minimum depth: 400 mm).
The plug-in 3NJ62 switch disconnectors with fuses are available
for rated uninterrupted currents from 160 A to 630 A.
LV HRC fuse links according to IEC 60269-1/EN 60269-1 (sizes
NH 00 to NH 3) or BS fuse links according to BS 88 provide overload and short-circuit protection up to 690 V AC.
The switch disconnectors can be retrofitted at any time with auxiliary switches, an ammeter (48 mm x 48 mm) and current transformers, with no extra space required. For installation in control
cabinets of > 400 mm depth, the mounting depth of the disconnectors can be increased by 200 mm using a contact extension.
Further installation accessories, such as guide rails and blanking covers, complete the product range.

EFM10 electronic fuse monitor

EFM20/25 electronic fuse monitor

Siemens LV 10.1 2011

7/65

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
Introduction

Technical specifications
Main devices of sizes 00 and 1
Size

BG00

Switch disconnectors with fuses


Type 3NJ62...

BS

...02-3
...02-4
...43-3

...53-3

Switching capacity

Size 1

NH

Rated insulation voltage Ui

Rated impulse withstand voltage Uimp

Rated operational current Ie

...03-1
...04-1
...04-2

...62-3
...62-4

...03-3
...03-4

...12-3
...12-4

...13-1
...14-1
...14-2

...13-3
...13-4

...63-3
...63-4

...72-3
...72-4

...74-1
...74-2

...73-3
...73-4

--

--

1000
8000
63

100

160

--

160

125

For LV HRC fuse links (NH type)

--

--

00 and 000

160

125

250
1

For BS fuse links acc. to BS 88

A3

A3

00T1)

B2

Rated operational voltage Ue


At 50/60Hz rated frequency
At DC

V
V

690
--

Utilization category

--

-230

-440

500
--

690
--

500
--

690
--

AC23B

DC23B DC21B

AC22B

AC23B

100
66

60
60

100
55

100
66

690
230

440

DC23B DC21B AC22B AC23B

Rated conditional short-circuit current


Short-circuit strength (rms value)
Short-circuit making capacity
(rms value)

kA
kA

60
60

100
55

66

Rated making capacity


p.f. = 0.65
p.f. = 0.45
p.f. = 0.35

A
A
A

-630
--

-1000
--

----

----

480
---

375
---

--1600

--1250

----

----

750
---

--2500

A
A
A

-504
--

-800
--

----

----

480
---

375
---

--1280

--1000

----

----

750
---

--2000

Rated breaking capacity


p.f. = 0.65
p.f. = 0.45
p.f. = 0.35
Endurance
Operating cycles total

2000

1600

1600

Electrical (690 V p.f. = 0.65)

300

200

200

Power loss (no fuse links)

Permissible ambient temperature

17

43

78
-5...+55

Horizontal and vertical with bottom connection

Permissible mounting positions

IP41

Degree of protection (in operating


state)

Main conductor connections

Connection type
Cable lug connection
Conductor cross-section
(Al/Cu, solid or stranded) acc. to
DIN 46235 (Cu) and DIN 46239 (Al)
Screw size
Torque

mm2

1x 10-95
2x 16-70

1x 25-240
2x 25-70

Nm

M8
15

M12
30

mm2
mm2
mm2
mm2
Nm

1x 10-50
1x 10-50
1x 16-95
1x 16-95
15

Terminal connection

1)

Conductor cross-section (Al/Cu), rm


Conductor cross-section (Al/Cu), re
Conductor cross-section (Al/Cu), sm
Conductor cross-section (Al/Cu), se
Required torque

The fuse is available from Lawson fuses (UK) and does not correspond to
BS 88.

7/66

Siemens LV 10.1 2011

1x
1x
1x
1x

16-185
16-150
35-240
35-300
25

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
Introduction
Main devices of sizes 2 and 3
Size

Size 2

3NJ62 switch disconnectors with fuses NH

...22-3
...22-4

BS

...82-3
...82-4

Size 3
...23-1
...24-1
...24-2

...23-3
...23-4

...32-3
...32-4

...33-1
...34-1
...34-2

...33-3
...33-4

...83-3
...83-4

...92-3
...92-4

...94-1
...94-2

...93-3
...93-4
...33-3
...33-4

Switching capacity

Rated insulation voltage Ui

1000

Rated impulse withstand voltage Uimp

8000

Rated operational current Ie


For fuse links acc. to IEC 60269/ BS88

400

For LV HRC fuse links (NH type)

630

500

2 and 1

3 and 2

B4

3T1)

For BS fuse links acc. to BS 88

630

500

500
--

690
--

Rated operational voltage Ue


At 50/60Hz rated frequency
At DC

V
V

Utilization category

-230

-440

690
--

DC23B

DC21B

AC22B

AC23B

230
--

440
--

DC23B

DC21B

500
--

690
-AC22B

AC23B

Rated conditional short-circuit current


Short-circuit strength (rms value)
Short-circuit making capacity
(rms value)

kA
kA

60
60

100
55

66

60
60

100
55

66

Rated making capacity


p.f. = 0.65
p.f. = 0.45
p.f. = 0.35

A
A
A

----

----

1200
---

--4000

----

----

1890
---

1500
---

--6300

--5000

A
A
A

----

----

1200
---

--3200

----

----

1890
---

1500
---

--5040

--4000

Rated breaking capacity


p.f. = 0.65
p.f. = 0.45
p.f. = 0.35
Endurance
Operating cycles total

1000

1000

electrical (690 V p.f. = 0.65)

200

200

158

357

Power loss
(no fuse links)

Permissible ambient temperature

-5...+55
Horizontal and vertical with bottom connection

Permissible mounting positions

IP41

Degree of protection (in operating


state)

Main conductor connections

Connection type
Cable lug connection
Conductor cross-section
Conductor cross-section
(Al/Cu, solid or stranded) acc. to
DIN 46235 (Cu) and DIN 46239 (Al)
Screw size
Torque

mm2

Nm

1x 25-300
2x 25-240

1x 25-300
2x 25-240

2x M12
30

2x M12
30

Terminal connection

1)

Conductor cross-section (Al/Cu), rm


Conductor cross-section (Al/Cu), re
Conductor cross-section (Al/Cu), sm
Conductor cross-section (Al/Cu), se
Required torque

mm2
mm2
mm2
mm2
Nm

2x
2x
2x
2x

16-185
16-150
35-240
35-300
25

2x
2x
2x
2x

16-185
16-150
35-240
35-300
25

The fuse is available from Lawson fuses (UK) and does not correspond to
BS 88.

Siemens LV 10.1 2011

7/67

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
Introduction
Auxiliary switches

Electronic fuse monitor, DC-version (EFM 25)

Acc. to IEC 60947-5-1

Size

2/3

690

Blind power uptake

VA

S approx. 2.5

Rated impulse withstand voltage Uimp

8000

Internal resistance of measurement


circuit

M

Rin > 6

A
A
A
A

8
6
4
2

Storage temperature
Operating temperature
Operating temperature
(500 V and/or 500 A)

C
C
C

- 20 ... + 80
- 5 ... + 55
- 5 ... + 35

Rated operational current Ie

At AC15, Ue = 120 V
At AC15, Ue = 230 V
At AC15, Ue = 400 V
At AC15, Ue = 690 V

Size

00

Blind power uptake

Rated operating voltage of the main


switching devices

V DC

S approx. 2.5

Voltage limits

15

Rin > 6

Undervoltage
Overvoltage

V
V

200
240

Voltage drop for faulty fuses

> 20

Delay time

VA

Internal resistance of measurement circuit M


Storage temperature
Operating temperature
Operating temperature (500 V or 500 A)

IP40

Protection rating in closed in-line


connector

Electronic fuse monitor AC-version (EFM 10)

00

Rated insulation voltage Ui

C
C
C

2/3

- 20 ... + 80
- 5 ... + 55
- 5 ... + 35
IP40

Protection rating in closed in-line


connector
Rated operating voltage of the main
switching devices

V AC
Hz

Voltage limits

15

Signaling relay acc. to IEC 60947-5-1

A
kV
V

Ith = 1.5
Uimp = 4
Ui = 250

220 ... 440

0.1
as relay 1
(fuse
monitor)

Relay 2

230 ... 690


50/60

Off

Storage function

Closed-circuit principle

Open/closed-circuit principle

Run mode

Mode

Display of
voltage values/
signals

Menu option

Load capacity of the signaling relay


Ue
DC - 13; Ie
AC - 15; Ie
Short-circuit protection

V
A
A

24
1

125
0.2
1.5

240
0.1

Max. fuse protection


Diazed 2 A gG

Size

00

VA

Rin > 6

C
C
C

Rated operating volatge of the main


switching devices

V AC
Hz

Voltage limits

15

Undervoltage
Overvoltage

V
V

375
425

Voltage drop for faulty fuses

> 13

Delay time

0.1

Moving-iron measuring instruments


Bi-metal measuring instruments

Display of
voltage values/
signals

Signaling relay acc. to IEC 60947-5-1

A
kV
V

Signaling relay 2

V
A
A

Short-circuit protection

7/68

Siemens LV 10.1 2011

24
1

125
0.2
1.5

240
0.1

Max. fuse protection


Diazed 2 A gG

-15

Power consumption
Moving-iron measuring instruments
Bi-metal measuring instruments

VA

0.6
1

VA

Motorized operating mechanisms


00

Control supply voltage

V DC

Power consumption

2/3

24 2
1.1

1.3

2.8

Service life (no limitation of circuit


breaker acc. to IEC 60947-3)
Operating cycles total

1600
200

Switch cycles under load


Signal duration

Load capacity of the signaling relay


Ue
DC - 13; Ie
AC - 15; Ie

min
min

Size

Ith = 1.5
Uimp = 4
Ui = 250
1 changeover for fuse
monitoring
1 changeover as output
for central fault
OR as signaling relay 1
(presetting)

Signaling relay 1

1.2 times
2 times

Slave pointer

Run mode

Menu option

x/1 A or x/5 A

Moving-iron measuring instruments


Bi-metal measuring instruments

Off

Mode

240
0.1

Overload

Closed-circuit principle

Open/closed-circuit principle

125
0.2
1.5

Max. fuse protection


Diazed 2 A gG

Inputs

as relay 1
(fuse
monitor)

Storage function

24
1

Ammeters

230 ... 690


50/60

Relay 2

V
A
A

Short-circuit protection

IP40

Protection rating in closed in-line


connector

Load capacity of the signaling relay


Ue
DC - 13; Ie
AC - 15; Ie

- 20 ... + 80
- 5 ... + 55
- 5 ... + 35

Ith = 1.5
Uimp = 4
Ui = 250
1 changeover for fuse
monitoring
1 changeover as output
for central fault
OR as signaling relay 1
(presetting)

Signaling relay 1

2/3

S approx. 2.5

Internal resistance of measurement circuit M


Storage temperature
Operating temperature
Operating temperature (500 V or 500 A)

A
kV
V

Signaling relay 2

Electronic fuse monitor, AC-version (EFM 20)


Blind power uptake

Signaling relay acc. to IEC 60947-5-1

min. 0.5 or
continuous signal

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC fuse links

Selection and ordering data


Rated current In

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

kg

2-pole, high switching capacity H


Manually operated N
160
250
400
630

00
1
2
3

Manually operated, EFM 25 N


160
250
400
630

00
1
2
3

Motorized operating mechanisms N


160
250
400
630

00
1
2
3

C
C
C
C

3NJ62 02-3AA0@-0AA0
3NJ62 12-3AA0@-0AA0
3NJ62 22-3AA0@-0AA0
3NJ62 32-3AA0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

C
C
C
C

3NJ62 02-3AE0@-0AA0
3NJ62 12-3AE0@-0AA0
3NJ62 22-3AE0@-0AA0
3NJ62 32-3AE0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

C
C
C
C

3NJ62 02-4AA0@-0AA0
3NJ62 12-4AA0@-0AA0
3NJ62 22-4AA0@-0AA0
3NJ62 32-4AA0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

Motorized operating mechanisms, EFM 25 N


160
250
400
630

3-pole, standard switching capacity S


Manually operated N
160
250
400
630

00
1
2
3

C
C
C
C

3NJ62 02-4AE0@-0AA0
3NJ62 12-4AE0@-0AA0
3NJ62 22-4AE0@-0AA0
3NJ62 32-4AE0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

7.450
7.450
15.700
16.060

00
1
2
3

A
A
A
A

3NJ62 03-1AA0@-@@@@
3NJ62 13-1AA0@-@@@@
3NJ62 23-1AA0@-@@@@
3NJ62 33-1AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

B
B
B
B

3NJ62 03-1AB0@-@@@@
3NJ62 13-1AB0@-@@@@
3NJ62 23-1AB0@-@@@@
3NJ62 33-1AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

00
1
2
3

B
B
B
B

3NJ62 03-1AC0@-@@@@
3NJ62 13-1AC0@-@@@@
3NJ62 23-1AC0@-@@@@
3NJ62 33-1AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

00
1
2
3

A
A
A
A

3NJ62 03-3AA0@-@@@@
3NJ62 13-3AA0@-@@@@
3NJ62 23-3AA0@-@@@@
3NJ62 33-3AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

B
B
B
B

3NJ62 03-3AB0@-@@@@
3NJ62 13-3AB0@-@@@@
3NJ62 23-3AB0@-@@@@
3NJ62 33-3AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

B
B
B
B

3NJ62 03-3AC0@-@@@@
3NJ62 13-3AC0@-@@@@
3NJ62 23-3AC0@-@@@@
3NJ62 33-3AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

C
C
C
C

3NJ62 03-4AA0@-@@@@
3NJ62 13-4AA0@-@@@@
3NJ62 23-4AA0@-@@@@
3NJ62 33-4AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

3NJ62 03-4AB0@-@@@@
3NJ62 13-4AB0@-@@@@
3NJ62 23-4AB0@-@@@@
3NJ62 33-4AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

4.330
7.450
15.700
16.060

3NJ62 03-4AC0@-@@@@
3NJ62 13-4AC0@-@@@@
3NJ62 23-4AC0@-@@@@
3NJ62 33-4AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

4.330
7.450
15.700
16.060

Manually operated, EFM 10 N


160
250
400
630

00
1
2
3

Manually operated, EFM 20 N


160
250
400
630

Weight
per PU
approx.

3-pole, high switching capacity H


Manually operated
160
250
400
630

Manually operated, EFM 10 N

160
250
400
630

00
1
2
3

Manually operated, EFM 20 N

160
250
400
630

00
1
2
3

Motorized operating mechanisms


160
250
400
630

00
1
2
3

Motorized operating mechanisms, EFM 10 N

160
250
400
630

00
1
2
3

C
C
C
C

Motorized operating mechanisms, EFM 20 N

160
250
400
630

00
1
2
3

C
C
C
C

Order No. supplement

Add. price

Standard Order No. supplement


(more Order No. supplements from page 7/73 onwards)
Without auxiliary switches, ammeters, current transformers

0 0AA0

None

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/69

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC fuse links
Rated current In

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

4-pole, standard switching capacity S


Manually operated
160
250
400
630

00
1
2
3

Manually operated, EFM 10 N

160
250
400
630

00
1
2
3

Manually operated, EFM 20 N

160
250
400
630

00
1
2
3

Motorized operating mechanisms N

160
250
400
630

00
1
2
3

A
A
A
A

3NJ62 04-1AA0@-@@@@
3NJ62 14-1AA0@-@@@@
3NJ62 24-1AA0@-@@@@
3NJ62 34-1AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.160
10.380
18.900
20.000

B
B
B
B

3NJ62 04-1AB0@-@@@@
3NJ62 14-1AB0@-@@@@
3NJ62 24-1AB0@-@@@@
3NJ62 34-1AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.830
9.950
18.200
18.560

B
B
B
B

3NJ62 04-1AC0@-@@@@
3NJ62 14-1AC0@-@@@@
3NJ62 24-1AC0@-@@@@
3NJ62 34-1AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.830
9.950
18.200
18.560

C
C
C
C

3NJ62 04-2AA0@-@@@@
3NJ62 14-2AA0@-@@@@
3NJ62 24-2AA0@-@@@@
3NJ62 34-2AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.160
10.380
18.900
20.000

3NJ62 04-2AB0@-@@@@
3NJ62 14-2AB0@-@@@@
3NJ62 24-2AB0@-@@@@
3NJ62 34-2AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

7.330
10.450
18.700
19.060

3NJ62 04-2AC0@-@@@@
3NJ62 14-2AC0@-@@@@
3NJ62 24-2AC0@-@@@@
3NJ62 34-2AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

7.330
10.450
18.700
19.060

Motorized operating mechanisms, EFM 10 N

160
250
400
630

00
1
2
3

C
C
C
C

Motorized operating mechanisms, EFM 20 N

160
250
400
630

00
1
2
3

C
C
C
C

Add. price

Order No. supplement

Standard Order No. supplement


(more Order No. supplements from page 7/73 onwards)
Without auxiliary switches, ammeters, current transformers

0 0AA0

None

* You can order this quantity or a multiple thereof.

7/70

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For BS fuse links

Selection and ordering data


Rated current In

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

kg

2-pole, high switching capacity H


Manually operated N
160
250
400
630

00T1)
B2
B4
3T1)

Manually operated, EFM 25 N

160
250
400
630

00T1)
B2
B4
3T1)

Motorized operating mechanisms N

160
250
400
630

Weight
per PU
approx.

00T1)
B2
B4
3T1)

C
C
C
C

3NJ62 62-3AA0@-0AA0
3NJ62 72-3AA0@-0AA0
3NJ62 82-3AA0@-0AA0
3NJ62 92-3AA0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

C
C
C
C

3NJ62 62-3AE0@-0AA0
3NJ62 72-3AE0@-0AA0
3NJ62 82-3AE0@-0AA0
3NJ62 92-3AE0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

C
C
C
C

3NJ62 62-4AA0@-0AA0
3NJ62 72-4AA0@-0AA0
3NJ62 82-4AA0@-0AA0
3NJ62 92-4AA0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

Motorized operating mechanisms, EFM 25 N


00T1)
B2
B4
3T1)

C
C
C
C

3NJ62 62-4AE0@-0AA0
3NJ62 72-4AE0@-0AA0
3NJ62 82-4AE0@-0AA0
3NJ62 92-4AE0@-0AA0

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

4.330
7.450
15.700
16.060

63
100
160

A3
A3
00T1)

C
C
C

3NJ62 43-3AA0@-@@@@
3NJ62 53-3AA0@-@@@@
3NJ62 63-3AA0@-@@@@

1
1
1

1 unit
1 unit
1 unit

143
143
143

3.630
3.630
3.630

250
400
630

B2
B4
3T1)

C
C
C

3NJ62 73-3AA0@-@@@@
3NJ62 83-3AA0@-@@@@
3NJ62 93-3AA0@-@@@@

1
1
1

1 unit
1 unit
1 unit

143
143
143

6.750
15.000
15.360

C
C
C
C

3NJ62 63-3AB0@-@@@@
3NJ62 73-3AB0@-@@@@
3NJ62 83-3AB0@-@@@@
3NJ62 93-3AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

C
C
C
C

3NJ62 63-3AC0@-@@@@
3NJ62 73-3AC0@-@@@@
3NJ62 83-3AC0@-@@@@
3NJ62 93-3AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.830
6.950
15.200
15.560

C
C
C
C

3NJ62 63-4AA0@-@@@@
3NJ62 73-4AA0@-@@@@
3NJ62 83-4AA0@-@@@@
3NJ62 93-4AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

3.630
6.750
15.000
15.360

3NJ62 63-4AB0@-@@@@
3NJ62 73-4AB0@-@@@@
3NJ62 83-4AB0@-@@@@
3NJ62 93-4AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

4.330
7.450
15.700
16.060

3NJ62 63-4AC0@-@@@@
3NJ62 73-4AC0@-@@@@
3NJ62 83-4AC0@-@@@@
3NJ62 93-4AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

4.330
7.450
15.700
16.060

160
250
400
630

3-pole, high switching capacity H


Manually operated

Manually operated, EFM 10 N

160
250
400
630

00T1)
B2
B4
3T1)

Manually operated, EFM 20 N

160
250
400
630

00T1)
B2
B4
3T1)

Motorized operating mechanisms


160
250
400
630

00T1)
B2
B4
3T1)

Motorized operating mechanisms, EFM 10 N

160
250
400
630

00T1)
B2
B4
3T1)

C
C
C
C

Motorized operating mechanisms, EFM 20 N

160
250
400
630

00T1)
B2
B4
3T1)

C
C
C
C

Order No. supplement

Add. price

Standard Order No. supplement


(more Order No. supplements from page 7/73 onwards)
Without auxiliary switches, ammeters, current transformers
1)

0 0AA0

None

The fuse is available from Lawson fuses (UK) and


does not correspond to BS 88.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/71

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For BS fuse links
Rated current In

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

kg

4-pole, standard switching capacity S


Manually operated
160
250
400
630

00T1)
B2
B4
3T1)

Manually operated, EFM 10 N

160
250
400
630

00T1)
B2
B4
3T1)

Manually operated, EFM 20 N

160
250
400
630

Weight
per PU
approx.

00T1)
B2
B4
3T1)

C
C
C
C

3NJ62 64-1AA0@-@@@@
3NJ62 74-1AA0@-@@@@
3NJ62 84-1AA0@-@@@@
3NJ62 94-1AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.160
10.380
18.900
20.000

C
C
C
C

3NJ62 64-1AB0@-@@@@
3NJ62 74-1AB0@-@@@@
3NJ62 84-1AB0@-@@@@
3NJ62 94-1AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.830
9.950
18.200
18.560

C
C
C
C

3NJ62 64-1AC0@-@@@@
3NJ62 74-1AC0@-@@@@
3NJ62 84-1AC0@-@@@@
3NJ62 94-1AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.830
9.950
18.200
18.560

C
C
C
C

3NJ62 64-2AA0@-@@@@
3NJ62 74-2AA0@-@@@@
3NJ62 84-2AA0@-@@@@
3NJ62 94-2AA0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

6.160
10.380
18.900
20.000

3NJ62 64-2AB0@-@@@@
3NJ62 74-2AB0@-@@@@
3NJ62 84-2AB0@-@@@@
3NJ62 94-2AB0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

7.330
10.450
18.700
19.060

3NJ62 64-2AC0@-@@@@
3NJ62 74-2AC0@-@@@@
3NJ62 84-2AC0@-@@@@
3NJ62 94-2AC0@-@@@@

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

7.330
10.450
18.700
19.060

Motorized operating mechanisms


160
250
400
630

00T1)
B2
B4
3T1)

Motorized operating mechanisms, EFM 10 N

160
250
400
630

00T1)
B2
B4
3T1)

C
C
C
C

Motorized operating mechanisms, EFM 20 N

160
250
400
630

00T1)
B2
B4
3T1)

C
C
C
C

Order No. supplement

Add. price

Standard Order No. supplement


(more Order No. supplements from page 7/73 onwards)
Without auxiliary switches, ammeters, current transformers
1)

0 0AA0

None

The fuse is available from Lawson fuses (UK) and


does not correspond to BS 88.

* You can order this quantity or a multiple thereof.

7/72

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links

Options
1. Order No. supplement:
Auxiliary switch wired to multi-function plug
DT

Order No. supplement


3NJ62 ..-....@-....

Additional
price

PS*/
P. unit

Without
1 NO contact

}
B

0
1

None

1 unit
1 unit

1 NC contact

1 unit

1 NO contact + 1 NC contact

1 unit

3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

2. Order No. supplement:


Ammeter and current transformer wired
Ammeters

Current transformers
Primary
current

Secondary
current

Without

Without

DT
Accuracy
class

Order No. supplement

For size NH 00 and BS 00T


Without

Without

0AA0

None

1 unit

T1

NSE0_01925

1 current transformer to 1 ammeter

Moving iron
Moving iron

50
50

1
5

1
1

B
B

1DB1
1DB4

1 unit
1 unit

Moving iron
Moving iron

100
100

1
5

1
1

B
B

1DD1
1DD4

1 unit
1 unit

Moving iron
Moving iron

150
150

1
5

1
1

B
B

1DE1
1DE4

1 unit
1 unit

Bi-metal
Bi-metal

50
50

1
5

1
1

B
B

2DB1
2DB4

1 unit
1 unit

Bi-metal
Bi-metal

100
100

1
5

1
1

B
B

2DD1
2DD4

1 unit
1 unit

Bi-metal
Bi-metal

150
150

1
5

1
1

B
B

2DE1
2DE4

1 unit
1 unit

NSE0_01967

1 current transformers to multi-function plug

T1

Without
Without

50
50

1
5

1
1

B
B

0BB1
0BB4

1 unit
1 unit

Without
Without
Without
Without
Without
Without

100
100
100
100
100
100

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BD1
0BD2
0 B D3
0BD4
0BD5
0BD6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

150
150
150
150
150
150

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BE1
0BE2
0BE3
0BE4
0BE5
0BE6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

3 current transformers to multi-function plug

T2
T3

NSE0_01968

T1

Without
Without

50
50

1
5

1
1

B
B

0CB1
0CB4

1 unit
1 unit

Without
Without
Without
Without
Without
Without

100
100
100
100
100
100

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CD1
0CD2
0CD3
0CD4
0CD5
0CD6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

150
150
150
150
150
150

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CE1
0CE2
0CE3
0CE4
0CE5
0CE6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/73

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 00 and BS 00T (continued)

T1

NSE0_01924

1 current transformer to 1 ammeter and multi-function plug

Moving iron
Moving iron

50
50

1
5

1
1

B
B

1EB1
1EB4

1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

100
100
100
100
100
100

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1ED1
1ED2
1ED3
1ED4
1ED5
1ED6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

150
150
150
150
150
150

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EE1
1EE2
1 E E3
1EE4
1EE5
1EE6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal

50
50

1
5

1
1

B
B

2EB1
2EB4

1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

100
100
100
100
100
100

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2ED1
2ED2
2ED3
2ED4
2ED5
2ED6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

150
150
150
150
150
150

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EE1
2EE2
2EE3
2EE4
2EE5
2EE6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

1 unit
1 unit

3 current transformers to 1 ammeter and multi-function plug

T1

T3

NSE0_01923

T2

Moving iron
Moving iron

50
50

1
5

1
1

B
B

1 FB 1
1 FB 4

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

100
100
100
100
100
100

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FD1
1FD2
1FD3
1 FD 4
1FD5
1FD6

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

150
150
150
150
150
150

1
5
5
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

Bi-metal
Bi-metal

50
50

1
5

1
1

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

100
100
100
100
100
100

1
1
1
5
5
5

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

150
150
150
150
150
150

1
1
1
5
5
5

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

1FE1
1FE2
1FE3
1FE4
1FE5
1FE6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

B
B

2FB1
2FB4

1 unit
1 unit

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FD1
2FD2
2FD3
2 FD 4
2 FD 5
2 FD 6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FE1
2FE2
2 F E3
2FE4
2FE5
2FE6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

7/74

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

Without

Without

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 1 and BS B2


Without

Without

0AA0

None

1 unit

T1

NSE0 01925

1 current transformer to 1 ammeter

Moving iron
Moving iron

50
50

1
5

1
1

B
B

1DB1
1DB4

1 unit
1 unit

Moving iron
Moving iron

100
100

1
5

1
1

B
B

1DD1
1DD4

1 unit
1 unit

Moving iron
Moving iron

150
150

1
5

1
1

B
B

1DE1
1DE4

1 unit
1 unit

Moving iron
Moving iron

200
200

1
5

1
1

B
B

1 D F1
1DF4

1 unit
1 unit

Moving iron
Moving iron

250
250

1
5

1
1

B
B

1DG
1DG4

1 unit
1 unit

Bi-metal
Bi-metal

50
50

1
5

1
1

B
B

2DB1
2DB4

1 unit
1 unit

Bi-metal
Bi-metal

100
100

1
5

1
1

B
B

2DD1
2DD4

1 unit
1 unit

Bi-metal
Bi-metal

150
150

1
5

1
1

B
B

2DE1
2DE4

1 unit
1 unit

Bi-metal
Bi-metal

200
200

1
5

1
1

B
B

2 D F1
2 D F4

1 unit
1 unit

Bi-metal
Bi-metal

250
250

1
5

1
1

B
B

2DG1
2DG4

1 unit
1 unit

NSE0_01967

1 current transformers to multi-function plug

T1

Without
Without

50
50

1
5

1
1

B
B

0BB1
0BB4

1 unit
1 unit

Without
Without
Without
Without

100
100
100
100

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0BD1
0BD2
0BD4
0BD5

1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without

150
150
150
150

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0BE1
0BE2
0BE4
0BE5

1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without

200
200
200
200

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0B F1
0BF2
0BF4
0BF5

1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without

250
250
250
250

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0BG1
0BG 2
0BG 4
0BG5

1 unit
1 unit
1 unit
1 unit

3 current transformers to multi-function plug

T2
T3

NSE0_01968

T1

Without
Without

50
50

1
5

1
1

B
B

0CB1
0CB4

1 unit
1 unit

Without
Without
Without
Without

100
100
100
100

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0C D 1
0C D 2
0C D 4
0C D 5

1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without

150
150
150
150

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0C E 1
0C E 2
0C E 4
0C E 5

1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without

200
200
200
200

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0C F 1
0C F 2
0 C F4
0CF5

1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without

250
250
250
250

1
1
5
5

1
0.5
1
0.5

B
B
B
B

0CG1
0CG2
0CG4
0CG5

1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/75

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 1 and BS B2 (continued)

T1

NSE0_01924

1 current transformer to 1 ammeter and multi-function plug

Moving iron
Moving iron

50
50

1
5

1
1

B
B

1EB1
1EB4

1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron

100
100
100
100

1
1
5
5

1
0.5
1
0.5

B
B
B
B

1ED1
1ED2
1ED4
1ED5

1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron

150
150
150
150

1
1
5
5

1
0.5
1
0.5

B
B
B
B

1EE1
1EE 2
1EE 4
1EE 5

1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

200
200
200
200
250
250
250
250

1
1
5
5
1
1
5
5

1
0.5
1
0.5
1
0.5
1
0.5

B
B
B
B
B
B
B
B

1EF1
1EF2
1EF4
1EF5
1EG1
1EG2
1EG4
1EG5

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal

50
50

1
5

1
1

B
B

2EB1
2EB4

1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

100
100
100
100

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2ED1
2E D2
2E D4
2E D5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

150
150
150
150

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2 EE1
2EE2
2EE4
2EE5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

200
200
200
200

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2 EF1
2EF2
2EF4
2EF5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

250
250
250
250

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2 EG 1
2 EG 2
2 EG 4
2 EG 5

1 unit
1 unit
1 unit
1 unit

3 current transformers to 1 ammeter and multi-function plug

T1

T3

NSE0_01923

T2

Moving iron
Moving iron

50
50

1
5

1
1

B
B

1FB1
1FB4

1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron

100
100
100
100

1
1
5
5

1
0.5
1
0.5

B
B
B
B

1FD1
1FD2
1FD4
1FD5

1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron

150
150
150
150

1
1
5
5

1
0.5
1
0.5

B
B
B
B

1FE1
1FE 2
1FE 4
1FE 5

1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron

200
200
200
200

1
1
5
5

1
0.5
1
0.5

B
B
B
B

1FF 1
1FF2
1FF4
1FF5

1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron

250
250
250
250

1
1
5
5

1
0.5
1
0.5

B
B
B
B

1FG1
1FG 2
1FG 4
1FG5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal

50
50

1
5

1
1

B
B

2 FB1
2FB4

1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

100
100
100
100

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2FD1
2F D2
2F D4
2F D5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

150
150
150
150

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2 FE1
2 F E2
2FE4
2FE5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

200
200
200
200

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2 FF1
2FF2
2FF4
2FF5

1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal

250
250
250
250

1
1
5
5

1
0.5
1
0.5

B
B
B
B

2 FG 1
2 FG 2
2 FG 4
2 FG 5

1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

7/76

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

Without

Without

DT

3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

0AA0

None

1 unit

Accuracy
class

Order No. supplement

For size NH 2 and BS B4


Without

T1

NSE0_01925

1 current transformer to 1 ammeter

Moving iron
Moving iron

300
300

1
5

1
1

B
B

1DH1
1DH4

1 unit
1 unit

Moving iron
Moving iron

400
400

1
5

1
1

B
B

1DJ1
1DJ4

1 unit
1 unit

Bi-metal
Bi-metal

300
300

1
5

1
1

B
B

2DH1
2DH4

1 unit
1 unit

Bi-metal
Bi-metal

400
400

1
5

1
1

B
B

2DJ1
2DJ4

1 unit
1 unit

NSE0_01967

1 current transformers to multi-function plug

T1

Without
Without
Without
Without
Without
Without

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BH1
0BH2
0BH3
0BH4
0BH5
0BH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BJ1
0BJ2
0BJ3
0BJ4
0BJ5
0BJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

3 current transformers to multi-function plug

NSE0_01968

T1
T2
T3

Without
Without
Without
Without
Without
Without

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CH1
0CH2
0 C H3
0CH4
0CH5
0CH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CJ1
0CJ2
0CJ3
0CJ4
0CJ5
0CJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

T1

NSE0_01924

1 current transformer to 1 ammeter and multi-function plug


Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EH1
1EH2
1EH3
1EH4
1EH5
1EH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EJ1
1EJ2
1EJ3
1EJ4
1EJ5
1EJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EH1
2EH2
2EH3
2EH4
2EH5
2EH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EJ1
2EJ2
2EJ3
2EJ4
2EJ5
2EJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/77

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 2 and BS B4 (continued)


3 current transformers to 1 ammeter and multi-function plug

T1

T3

NSE0_01923

T2

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FH1
1FH2
1FH3
1FH4
1FH5
1FH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FJ1
1FJ2
1FJ3
1FJ4
1FJ5
1FJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FH1
2FH2
2FH3
2FH4
2FH5
2FH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FJ1
2FJ2
2FJ3
2FJ4
2FJ5
2FJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

7/78

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 3 and BS 3T


Without

Without Without

Without

0AA0

None

1 unit

T1

NSE0 01925

1 current transformer to 1 ammeter

Moving iron
Moving iron

300
300

1
5

1
1

B
B

1DH1
1DH4

1 unit
1 unit

Moving iron
Moving iron

400
400

1
5

1
1

B
B

1DJ1
1DJ4

1 unit
1 unit

Moving iron
Moving iron

500
500

1
5

1
1

B
B

1DK1
1DK4

1 unit
1 unit

Moving iron
Moving iron

600
600

1
5

1
1

B
B

1DL1
1DL4

1 unit
1 unit

Bi-metal
Bi-metal

300
300

1
5

1
1

B
B

2DH1
2DH4

1 unit
1 unit

Bi-metal
Bi-metal

400
400

1
5

1
1

B
B

2DJ1
2DJ4

1 unit
1 unit

Bi-metal
Bi-metal

500
500

1
5

1
1

B
B

2DK1
2DK4

1 unit
1 unit

Bi-metal
Bi-metal

600
600

1
5

1
1

B
B

2DL1
2DL4

1 unit
1 unit

NSE0_01967

1 current transformers to multi-function plug

T1

Without
Without
Without
Without
Without
Without

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BH1
0BH2
0BH3
0BH4
0BH5
0BH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BJ1
0BJ2
0BJ3
0BJ4
0BJ5
0BJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

500
500
500
500
500
500

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BK1
0BK2
0BK3
0BK4
0BK5
0BK6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

600
600
600
600
600
600

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0BL1
0BL2
0BL3
0BL4
0BL5
0BL6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

3 current transformers to multi-function plug

T2
T3

NSE0_01968

T1

Without
Without
Without
Without
Without
Without

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CH1
0CH2
0CH3
0 CH 4
0CH5
0CH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CJ1
0CJ2
0CJ3
0CJ4
0CJ5
0CJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

500
500
500
500
500
500

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CK1
0CK2
0CK3
0CK4
0CK5
0CK6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Without
Without
Without
Without
Without
Without

600
600
600
600
600
600

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

0CL1
0CL2
0CL3
0CL4
0CL5
0CL6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/79

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 3 and BS 3T (continued)

T1

NSE0_01924

1 current transformer to 1 ammeter and multi-function plug


Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

400
400
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EH1
1 EH 2
1EH3
1EH4
1EH5
1EH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EJ1
1EJ2
1EJ3
1EJ4
1EJ5
1EJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

500
500
500
500
500
500

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EK1
1EK2
1EK3
1EK4
1EK5
1EK6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

600
600
600
600
600
600

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1EL1
1EL2
1 E L3
1EL4
1EL5
1EL6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EH1
2EH2
2EH3
2EH4
2EH5
2EH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EJ1
2EJ2
2EJ3
2EJ4
2EJ5
2EJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

500
500
500
500
500
500

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EK1
2EK2
2EK3
2EK4
2EK5
2EK6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

600
600
600
600
600
600

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2EL1
2EL2
2EL3
2EL4
2EL5
2EL6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

7/80

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 In-line Switch Disconnectors with Fuses up to 630 A
For LV HRC and BS fuse links
Ammeters

Current transformers
Primary
current

Secondary
current

DT
Accuracy
class

Order No. supplement


3NJ62 ..-.....-@@@@

Additional
price

PS*/
P. unit

For size NH 3 and BS 3T (continued)


3 current transformer to 1 ammeter and multi-function plug

T1

T3

NSE0_01923

T2

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FH1
1FH2
1FH3
1FH4
1FH5
1FH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FJ1
1FJ2
1FJ3
1FJ4
1FJ5
1FJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

500
500
500
500
500
500

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FK1
1FK2
1FK3
1FK4
1FK5
1FK6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Moving iron
Moving iron
Moving iron
Moving iron
Moving iron
Moving iron

600
600
600
600
600
600

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

1FL1
1FL2
1FL3
1FL4
1FL5
1FL6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

300
300
300
300
300
300

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FH1
2FH2
2FH3
2FH4
2FH5
2FH6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

400
400
400
400
400
400

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FJ1
2FJ2
2FJ3
2FJ4
2FJ5
2FJ6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

500
500
500
500
500
500

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FK1
2FK2
2FK3
2FK4
2FK5
2FK6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal
Bi-metal

600
600
600
600
600
600

1
1
1
5
5
5

1
0.5
0.5 calibrated
1
0.5
0.5 calibrated

B
B
D
B
B
D

2FL1
2FL2
2FL3
2FL4
2FL5
2FL6

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/81

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories

Selection and ordering data


Version

DT

Order No.

Price per
PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH 00, BS A3 and BS 00T


Terminals

3NJ69 23-1BA00

Single terminal for 2-/3-pole devices, 10 ... 95 mm2


(1 set = 3 units)

3NJ69 23-1BA00

1 unit

143

0.210

Single terminal for 4-pole devices, 10 ... 95 mm2


(1 set = 4 units)

3NJ69 24-1BA00

1 unit

143

0.280

For 2-/3-pole devices

3NJ69 23-1DA00

1 unit

143

0.063

Only for 4th pole

3NJ69 04-1DA00

1 unit

143

0.070

3-pole

3NJ69 23-1EB00

1 unit

143

1.700

4-pole

3NJ69 24-1EB00

1 unit

143

2.000

EFM 10 electronic fuse monitoring for AC networks

3NJ69 20-3FB00

1 unit

143

0.400

EFM 20 electronic fuse monitoring for AC networks

3NJ69 20-3FC00

1 unit

143

0.450

EFM 25 electronic fuse monitoring for DC networks

3NJ69 20-3FE00

1 unit

143

0.450

1 NO contact (1 NO) with cover

3NJ69 20-2BB00

1 unit

143

0.080

1 NO contact (1 NO)

3NJ69 00-2BC00

1 unit

143

0.020

1 unit

143

0.080

Terminal covers

3NJ69 23-1DA00
Contact extensions

3NJ69 23-1EB00
Electronic fuse monitor and line monitor

3NJ69 23-3FB00

3NJ69 23-3FC00
Auxiliary switches

3NJ69 20-2BB00

1 NC contact (1 NC) with cover

3NJ69 20-2CB00

1 NC contact (1 NC)

3NJ69 00-2CC00

1 unit

143

0.020

A
A

3NJ69 20-3BB11
3NJ69 20-3BB21

1
1

1 unit
1 unit

143
143

0.160
0.160

3NJ69 00-2BC00
Current transformers for main devices and contact
extensions
 = Feed-through opening diameter

3NJ69 20-3BD11

1 VA,  21 mm
1 VA,  21 mm

50 A / 1 A
50 A / 5 A

Class 1
Class 1

100 A / 1 A
100 A / 1 A
100 A / 1 A

Class 1
2.5 VA,  21 mm
Class 0.5
1.5 VA,  21 mm
Class 0.5 calibrated 1.5 VA,  14 mm

A
A
D

3NJ69 20-3BD11
3NJ69 20-3BD12
3NJ69 20-3BD13

1
1
1

1 unit
1 unit
1 unit

143
143
143

0.160
0.160
0.160

100 A / 5 A
100 A / 5 A
100 A / 5 A

Class 1
2.5 VA,  21 mm
Class 0.5
1.5 VA,  21 mm
Class 0.5 calibrated 1.5 VA,  14mm

A
A
D

3NJ69 20-3BD21
3NJ69 20-3BD22
3NJ69 20-3BD23

1
1
1

1 unit
1 unit
1 unit

143
143
143

0.160
0.160
0.160

150 A / 1 A
150 A / 1 A
150 A / 1 A

Class 1
2.5 VA,  21 mm
Class 0.5
1.5 VA,  21 mm
Class 0.5 calibrated 2.5 VA,  14 mm

A
A
D

3NJ69 20-3BE11
3NJ69 20-3BE12
3NJ69 20-3BE13

1
1
1

1 unit
1 unit
1 unit

143
143
143

0.170
0.170
0.170

150 A / 5 A
150 A / 5 A
150 A / 5 A

Class 1
1.5 VA,  21 mm
Class 0.5
1.5 VA,  21 mm
Class 0.5 calibrated 2.5 VA,  14 mm

A
A
D

3NJ69 20-3BE21
3NJ69 20-3BE22
3NJ69 20-3BE23

1
1
1

1 unit
1 unit
1 unit

143
143
143

0.170
0.170
0.170

* You can order this quantity or a multiple thereof.

7/82

Siemens LV 1 0.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories
Version

DT

Order No.

Price per
PU

PU
(UNIT.
SET. M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH 00, BS A3 and BS 00T (continued)


Current transformer busbars for current transformers with feed-through opening  21 mm
3NJ69 20-3DB00

For 1 current transformers

3NJ69 20-3DB00

1 unit

143

0.070

For 3 current transformers

3NJ69 20-3DC00

1 unit

143

0.210

For 4 current transformers1)

3NJ69 20-3DD00

1 unit

143

0.280

Current transformer busbars for current transformers with feed-through opening  14 mm


3NJ69 20-3DC00

For 1 current transformers

3NJ69 20-3DE00

1 unit

143

0.070

For 3 current transformers

3NJ69 20-3DF00

1 unit

143

0.210

For 4 current transformers1)

3NJ69 20-3DG00

1 unit

143

0.280

Holders for ammeters

3NJ69 00-4GA00

1 unit

143

0.040

3NJ69 20-3DD00
For sizes 00, 1, 2, 3

3NJ69 00-4GA00
Ammeters
Moving-iron measuring instruments for measurements on transformer x/1A with double overload

3NJ69 00-4H...

50 A / 1 A

0.6 VA

3NJ69 00-4HB11

1 unit

143

0.100

100 A / 1 A

0.6 VA

3NJ69 00-4HD11

1 unit

143

0.100

150 A / 1 A

0.6 VA

3NJ69 00-4HE11

1 unit

143

0.100

Moving-iron measuring instruments for measurements on transformer x/5A with double overload
50 A / 5 A

0.6 VA

3NJ69 00-4HB21

1 unit

143

0.100

100 A / 5 A

0.6 VA

3NJ69 00-4HD21

1 unit

143

0.100

150 A / 5 A

0.6 VA

3NJ69 00-4HE21

1 unit

143

0.100

Bi-metal measuring instruments for measurements


on transformer x/1A with 1.2-times the overload
50 A / 1 A

1 VA

3NJ69 00-4HB12

1 unit

143

0.100

100 A / 1 A

1 VA

3NJ69 00-4HD12

1 unit

143

0.100

150 A / 1 A

1 VA

3NJ69 00-4HE12

1 unit

143

0.100

Bi-metal measuring instruments for measurements


on transformer x/5A with 1.2-times the overload
3NJ69 00-4H...

50 A / 5 A

1 VA

3NJ69 00-4HB22

1 unit

143

0.100

100 A / 5 A

1 VA

3NJ69 00-4HD22

1 unit

143

0.100

150 A / 5 A

1 VA

3NJ69 00-4HE22

1 unit

143

0.100

Multi-function plugs
6 x 2.5 mm2, with fixing screws

3NJ69 20-3EB00

1 unit

143

0.047

8 x 2.5 mm2, without fixing screws

3NJ69 20-3ED00

1 unit

143

0.047

10 x 1.5 mm2 and 8 x 2.5 mm2,


without fixing screws

3NJ69 20-3EE00

1 unit

143

0.070

For NH: 3NJ62 03-1AA... and 3NJ62 03-3AA...


without/with EFM

3NJ69 23-4BB00

1 unit

143

0.400

For BS: 3NJ62 03-1AA... and 3NJ62 03-3AA...


without/with EFM

3NJ69 23-4BC00

1 unit

143

0.400

3NJ69 20-3EB00

3NJ69 20-3ED00

3NJ69 20-3EE00
Front panel
3NJ69 23-4BB00

1)

Not available in combination with multi-function plug

* You can order this quantity or a multiple thereof.

Siemens LV 1 0.1 2011

7/83

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories
Version

DT

Order No.

Price per
PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH 1 and BS B2


Terminals

3NJ69 33-1BA00

Single terminal for 2-/3-pole devices, 16 ... 300 mm2


(1 set = 3 units)

3NJ69 33-1BA00

1 unit

143

0.230

Single terminal for 4-pole devices, 16 ... 300 mm2


(1 set = 4 units)

3NJ69 34-1BA00

1 unit

143

0.310

For 2-/3-pole devices

3NJ69 33-1DA00

1 unit

143

0.146

Internal terminal covers for 2-/3-pole devices

3NJ69 33-1DB00

1 unit

143

0.020

Only for 4th pole

3NJ69 04-1DA00

1 unit

143

0.070

3-pole

3NJ69 33-1EB00

1 unit

143

2.400

4-pole

3NJ69 34-1EB00

1 unit

143

2.800

EFM 10 electronic fuse monitoring for AC networks

3NJ69 30-3FB00

1 unit

143

0.400

EFM 20 electronic fuse monitoring for AC networks

3NJ69 30-3FC00

1 unit

143

0.450

EFM 25 electronic fuse monitoring for DC networks

3NJ69 30-3FE00

1 unit

143

0.450

1 NO contact (1 NO) with cover

3NJ69 30-2BB00

1 unit

143

0.050

1 NO contact (1 NO)

3NJ69 00-2BC00

1 unit

143

0.020

1 NC contact (1 NC) with cover

3NJ69 30-2CB00

1 unit

143

0.050

1 NC contact (1 NC)

3NJ69 00-2CC00

1 unit

143

0.020

Terminal covers

3NJ69 33-1DA00

3NJ69 33-1DB00
Contact extensions

3NJ69 33-1EB00
Electronic fuse monitor and line monitor

3NJ69 23-3FB00

3NJ69 23-3FC00
Auxiliary switches

3NJ69 30-2BB00

3NJ69 00-2BC00
Current transformers
For main devices and contact extensions
 = Feed-through opening diameter

3NJ69 20-3BD11

50 A / 1 A
50 A / 5 A

Class 1
Class 1

1 VA,  21 mm
1 VA,  21 mm

A
A

3NJ69 20-3BB11
3NJ69 20-3BB21

1
1

1 unit
1 unit

143
143

0.160
0.160

100 A / 1 A
100 A / 1 A
100 A / 5 A
100 A / 5 A

Class 1
Class 0.5
Class 1
Class 0.5

2.5 VA,  21 mm
1.5 VA,  21 mm
2.5 VA,  21 mm
1.5 VA,  21 mm

A
A
A
A

3NJ69 20-3BD11
3NJ69 20-3BD12
3NJ69 20-3BD21
3NJ69 20-3BD22

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

0.160
0.160
0.160
0.160

150 A / 1 A
150 A / 1 A
150 A / 5 A
150 A / 5 A

Class 1
Class 0.5
Class 1
Class 0.5

2.5 VA,  21 mm
1.5 VA,  21 mm
1.5 VA,  21 mm
1.5 VA,  21 mm

A
A
A
A

3NJ69 20-3BE11
3NJ69 20-3BE12
3NJ69 20-3BE21
3NJ69 20-3BE22

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

0.170
0.170
0.170
0.170

200 A / 1 A
200 A / 1 A
200 A / 5 A
200 A / 5 A

Class 1
Class 0.5
Class 1
Class 0.5

2.5 VA,  21 mm
5 VA,  21 mm
2.5 VA,  21 mm
2.5 VA,  21 mm

A
A
A
A

3NJ69 30-3BF11
3NJ69 30-3BF12
3NJ69 30-3BF21
3NJ69 30-3BF22

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

0.180
0.180
0.180
0.180

250 A / 1 A
250 A / 1 A
250 A / 5 A
250 A / 5 A

Class 1
Class 0.5
Class 1
Class 0.5

5 VA,  21 mm
5 VA,  21 mm
2.5 VA,  21 mm
2.5 VA,  21 mm

A
A
A
A

3NJ69 30-3BG11
3NJ69 30-3BG12
3NJ69 30-3BG21
3NJ69 30-3BG22

1
1
1
1

1 unit
1 unit
1 unit
1 unit

143
143
143
143

0.180
0.180
0.180
0.180

* You can order this quantity or a multiple thereof.

7/84

Siemens LV 1 0.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories
Version

DT

Order No.

Price per
PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH 1 and BS B2 (continued)


Current transformer busbars for current transformers with feed-through opening  21 mm

3NJ69 30-3DB00

For 1 current transformers

3NJ69 30-3DB00

1 unit

143

0.210

For 3 current transformers

3NJ69 30-3DC00

1 unit

143

0.310

For 4 current transformers1)

3NJ69 30-3DD00

1 unit

143

0.410

Holders for ammeters

3NJ69 00-4GA00

1 unit

143

0.040

A
A
A
A
A

3NJ69 00-4HB11
3NJ69 00-4HD11
3NJ69 00-4HE11
3NJ69 00-4HF11
3NJ69 00-4HG11

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143

0.100
0.100
0.100
0.100
0.100

A
A
A
A
A

3NJ69 00-4HB21
3NJ69 00-4HD21
3NJ69 00-4HE21
3NJ69 00-4HF21
3NJ69 00-4HG21

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143

0.100
0.100
0.100
0.100
0.100

A
A
A
A
A

3NJ69 00-4HB12
3NJ69 00-4HD12
3NJ69 00-4HE12
3NJ69 00-4HF12
3NJ69 00-4HG12

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143

0.100
0.100
0.100
0.100
0.100

A
A
A
A
A

3NJ69 00-4HB22
3NJ69 00-4HD22
3NJ69 00-4HE22
3NJ69 00-4HF22
3NJ69 00-4HG22

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143

0.100
0.100
0.100
0.100
0.100

6 x 2.5 mm2, with fixing screws

3NJ69 20-3EB00

1 unit

143

0.047

8 x 2.5 mm2, without fixing screws

3NJ69 20-3ED00

1 unit

143

0.047

10 x 1.5 mm2 and 8 x 2.5 mm2,


without fixing screws

3NJ69 20-3EE00

1 unit

143

0.070

For NH: 3NJ62 13-1AA... and 3NJ62 13-3AA...


without/with EFM

3NJ69 33-4BB00

1 unit

143

0.500

For BS: 3NJ62 13-1AA... and 3NJ62 13-3AA...


without/with EFM

3NJ69 33-4BC00

1 unit

143

0.500

3NJ69 30-3DC00

3NJ69 30-3DD00

For sizes 00, 1, 2, 3

3NJ69 00-4GA00
Ammeters
Moving-iron measuring instruments for measurements on transformer x/1A with double overload

3NJ69 00-4H...

50 A / 1 A
100 A / 1 A
150 A / 1 A
200 A / 1 A
250 A / 1 A

0.6 VA
0.6 VA
0.6 VA
0.6 VA
0.6 VA

Moving-iron measuring instruments for measurements on transformer x/5A with double overload
50 A / 5 A
100 A / 5 A
150 A / 5 A
200 A / 5 A
250 A / 5 A

0.6 VA
0.6 VA
0.6 VA
0.6 VA
0.6 VA

Bi-metal measuring instruments for measurements


on transformer x/1A with 1.2-times the overload
50 A / 1 A
100 A / 1 A
150 A / 1 A
200 A / 1 A
250 A / 1 A
3NJ69 00-4H...

1 VA
1 VA
1 VA
1 VA
1 VA

Bi-metal measuring instruments for measurements


on transformer x/5A with 1.2-times the overload
50 A / 5 A
100 A / 5 A
150 A / 5 A
200 A / 5 A
250 A / 5 A

1 VA
1 VA
1 VA
1 VA
1 VA

Multi-function plugs

3NJ69 20-3EB00

3NJ69 40-3EE00
Front panel
3NJ69 33-4BB00

1)

Not available in combination with multi-function plug.

* You can order this quantity or a multiple thereof.

Siemens LV 1 0.1 2011

7/85

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories
Version

DT

Order No.

Price per
PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH 2, NH 3, BS B4 and BS 3T


Terminals

3NJ69 43-1CA00

Double terminal for 2-/3-pole devices,


2 x (16 mm2 ... 300 mm2, 1 set = 6 units)
Double terminal for 4-pole devices,
2 x (16 mm2 ... 300 mm2, 1 set = 8 units)

3NJ69 43-1CA00

1 unit

143

0.450

3NJ69 44-1CA00

1 unit

143

0.600

For 2-/3-pole devices

3NJ69 43-1DA00

1 unit

143

0.195

Only for 4th pole

3NJ69 04-1DA00

1 unit

143

0.070

3-pole

3NJ69 43-1EB00

1 unit

143

8.400

4-pole

3NJ69 44-1EB00

1 unit

143

9.200

EFM 10 electronic fuse monitoring for AC networks

3NJ69 40-3FB00

1 unit

143

0.400

EFM 20 electronic fuse monitoring for AC networks

3NJ69 40-3FC00

1 unit

143

0.450

EFM 25 electronic fuse monitoring for DC networks

3NJ69 40-3FE00

1 unit

143

0.450

1 NO contact (1 NO) with cover

3NJ69 40-2BB00

1 unit

143

0.024

1 NO contact (1 NO)

3NJ69 00-2BC00

1 unit

143

0.020

1 NC contact (1 NC) with cover

3NJ69 40-2CB00

1 unit

143

0.024

1 NC contact (1 NC)

3NJ69 00-2CC00

1 unit

143

0.020

Terminal covers

3NJ69 43-1DA00
Contact extensions

3NJ69 44-1EB00
Electronic fuse monitor and line monitor

3NJ69 23-3FB00

3NJ69 23-3FC00
Auxiliary switches

3NJ69 40-2BB00

3NJ69 00-2BC00
Current transformers
For main devices and contact extensions

3NJ69 40-3B...

300 A / 1 A
300 A / 1 A
300 A / 1 A
300 A / 5 A
300 A / 5 A
300 A / 5 A

Class 1
Class 0.5
Class 0.5 calibrated
Class 1
Class 0.5
Class 0.5 calibrated

5 VA
5 VA
5 VA
5 VA
5 VA
5 VA

A
A
D
A
A
D

3NJ69 40-3BH11
3NJ69 40-3BH12
3NJ69 40-3BH13
3NJ69 40-3BH21
3NJ69 40-3BH22
3NJ69 40-3BH23

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143
143

0.330
0.330
0.330
0.330
0.330
0.330

400 A / 1 A
400 A / 1 A
400 A / 1A
400 A / 5 A
400 A / 5 A
400 A / 5 A

Class 1
Class 0.5
Class 0.5 calibrated
Class 1
Class 0.5
Class 0.5 calibrated

5 VA
5 VA
5 VA
5 VA
5 VA
5 VA

A
A
D
A
A
D

3NJ69 40-3BJ11
3NJ69 40-3BJ12
3NJ69 40-3BJ13
3NJ69 40-3BJ21
3NJ69 40-3BJ22
3NJ69 40-3BJ23

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143
143

0.430
0.430
0.430
0.430
0.430
0.430

500 A / 1 A
500 A / 1 A
500 A / 1 A
500 A / 5 A
500 A / 5 A
500 A / 5 A

Class 1
Class 0.5
Class 0.5 calibrated
Class 1
Class 0.5
Class 0.5 calibrated

5 VA
5 VA
5 VA
5 VA
5 VA
5 VA

A
A
D
A
A
D

3NJ69 40-3BK11
3NJ69 40-3BK12
3NJ69 40-3BK13
3NJ69 40-3BK21
3NJ69 40-3BK22
3NJ69 40-3BK23

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143
143

0.460
0.460
0.460
0.460
0.460
0.460

600 A / 1 A
600 A / 1 A
600 A / 1 A
600 A / 5 A
600 A / 5 A
600 A / 5 A

Class 1
Class 0.5
Class 0.5 calibrated
Class 1
Class 0.5
Class 0.5 calibrated

5 VA
5 VA
5 VA
5 VA
5 VA
5 VA

A
A
D
A
A
D

3NJ69 40-3BL11
3NJ69 40-3BL12
3NJ69 40-3BL13
3NJ69 40-3BL21
3NJ69 40-3BL22
3NJ69 40-3BL23

1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143
143

0.460
0.460
0.460
0.460
0.460
0.460

* You can order this quantity or a multiple thereof.

7/86

Siemens LV 1 0.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories
Version

DT

Order No.

Price per
PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH 2, NH 3, BS B4 and BS 3T (continued)


Holders for ammeters

3NJ69 00-4GA00

1 unit

143

0.040

For sizes 00, 1, 2, 3

3NJ69 00-4GA00
Ammeters
Moving-iron measuring instruments for measuring
input on transformer x/1A with double overload

3NJ69 00-4H...

300 A / 1 A

0.6 VA

3NJ69 00-4HH11

1 unit

143

0.100

400 A / 1 A

0.6 VA

3NJ69 00-4HJ11

1 unit

143

0.100

500 A / 1 A

0.6 VA

3NJ69 00-4HK11

1 unit

143

0.100

600 A / 1 A

0.6 VA

3NJ69 00-4HL11

1 unit

143

0.100

Moving-iron measuring instruments for measuring


input on transformer x/5A with double overload
300 A / 5 A

0.6 VA

3NJ69 00-4HH21

1 unit

143

0.100

400 A / 5 A

0.6 VA

3NJ69 00-4HJ21

1 unit

143

0.100

500 A / 5 A

0.6 VA

3NJ69 00-4HK21

1 unit

143

0.100

600 A / 5 A

0.6 VA

3NJ69 00-4HL21

1 unit

143

0.100

Bi-metal measuring instruments for measurements


on transformer x/1A with 1.2-times the overload

3NJ69 00-4H...

300 A / 1 A

1 VA

3NJ69 00-4HH12

1 unit

143

0.100

400 A / 1 A

1 VA

3NJ69 00-4HJ12

1 unit

143

0.100

500 A / 1 A

1 VA

3NJ69 00-4HK12

1 unit

143

0.100

600 A / 1 A

1 VA

3NJ69 00-4HL12

1 unit

143

0.100

Bi-metal measuring instruments for measurements


on transformer x/5A with 1.2-times the overload
300 A / 5 A

1 VA

3NJ69 00-4HH22

1 unit

143

0.100

400 A / 5 A

1 VA

3NJ69 00-4HJ22

1 unit

143

0.100

500 A / 5 A

1 VA

3NJ69 00-4HK22

1 unit

143

0.100

600 A / 5 A

1 VA

3NJ69 00-4HL22

1 unit

143

0.100

8 x 2.5 mm2, with fixing screws

3NJ69 40-3EC00

1 unit

143

0.147

8 x 2.5 mm2, without fixing screws

3NJ69 40-3ED00

1 unit

143

0.147

12 x 1.5 mm2 and 8 x 2.5 mm2,


without fixing screws

3NJ69 40-3EF00

1 unit

143

0.170

For NH: 3NJ62 23-1AA... and 3NJ62 23-3AA...


without/with EFM

3NJ69 43-4BB00

1 unit

143

0.700

For BS: 3NJ62 23-1AA... and 3NJ62 23-3AA...


without/with EFM

3NJ69 43-4BC00

1 unit

143

0.700

For NH: 3NJ62 33-1AA... and 3NJ62 33-3AA...


without/with EFM

3NJ69 53-4BB00

1 unit

143

0.700

For BS: 3NJ62 33-1AA... and 3NJ62 33-3AA...


without/with EFM

3NJ69 53-4BC00

1 unit

143

0.700

Multi-function plugs

3NJ69 40-3EC00

3NJ69 40-3ED00

3NJ69 40-3EF00
Front panel

3NJ69 43-4BB00

* You can order this quantity or a multiple thereof.

Siemens LV 1 0.1 2011

7/87

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A
Accessories
Version

DT

Order No.

Price per
PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Common accessories
Busbar covers
Mounting height 200 mm, IP20

3NJ69 16-4EA00

1 unit

113

0.472

3NJ69 00-4CB00

1 unit

143

0.800

For power takeoff from field distribution bus up to 400 A A

3NJ69 15-3BA00

1 unit

113

1.524

3NJ69 16-4EA00
Blanking covers
Mounting height 50 mm, IP41
3NJ69 00-4CB00
Connection modules

3NJ69 15-3BA00
Guide rails
Depth 200 mm (1 x left and 1 x right)

3NJ69 00-4FB00

1 unit

143

1.300

Depth 400 mm (1 x left and 1 x right)

3NJ69 00-4FC00

1 unit

143

1.800

For NH00

XPT:8PT9624

1 unit

195

0.497

For NH1, 2, 3

XPT:8PT9625

1 unit

195

0.505

3NJ69 00-4FB00

3NJ69 00-4FC00
NH fuse puller tongs

* You can order this quantity or a multiple thereof.

7/88

Siemens LV 1 0.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Introduction

Overview
All key product features at a glance
Box terminals available for all sizes
Connection of circular conductors and laminated conductors
Fuse monitoring possible throughout
Busbar supports can be built over
Conversion of 5 /10 mm thick busbars without parts which can
be lost or broken off
Convertibility of cable feeder at top/bottom without intervention in the internal conducting paths
Optimum integration in various system environments through
cover levels and on busbar systems with/without base
Touch protection also with rear incoming unit
Fuses are removed using a release shaft without the fuses
being touched
All units can be sealed and locked

3NP1 Fuse Switch Disconnectors

Overview of components and accessory parts













NSG0_00235












Box terminal



Auxiliary conductor connection for box terminal

Reach-around protection for Siemens busbar system



Flat connector

Reach-around protection for Rittal busbar system



Auxiliary conductor connection for flat connector

Locking device



Deep-drawn connection module

Auxiliary switch with actuator



Prism terminal

Molded-plastic masking frame



Auxiliary conductor connection for prism terminal

Fuse carrier with MFM electromechanical fuse monitoring



Saddle terminal

Fuse carrier with EFM 10 electronic fuse monitoring



Cable connection cover

 Fuse carrier with EFM 20/25 electronic fuse monitoring



Cable connection cover with rear reach-around protection

SENTRON 3NP1 fuse switch disconnector

Cover support





Siemens LV 10.1 2011

7/89

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Introduction

Benefits
Advantages during planning and configuration
Low level of equipment variance through easy convertibility of
cable feeder at top/bottom (delivered from factory with cable
feeder at bottom).
Only one device variant for applications in industry and infrastructure thanks to touch and reach-around protection as a
standard feature.
Uniform grid sizes for easy configuration.

Application
Possible uses

Mounting

3NP1 fuse switch disconnectors can be used for protecting and


switching the most diverse electrical loads:
Motor starter combinations
In conjunction with SITOR fuses for the protection of frequency
converters and soft starters
Fusing of compensation modules
Cable feeders
Group fusing of small loads

Floor mounting

The devices are optimized for operation in all kinds of system


environments:
Low-voltage switchboards for power distribution and MCCs
(e.g. main and sub-distribution boards)
Distribution systems with cover levels of 32 and 70 mm or
45 and 70 mm
Mechanical engineering
Railway applications
Fuse monitors are used to detect, indicate and report faults:
MFM electromechanical fuse monitoring for AC/DC networks
EFM 10 electronic fuse monitoring for AC networks
EFM 20 electronic fuse monitoring with line monitoring for
AC networks
EFM 25 electronic fuse monitoring with line monitoring for
DC networks

45

70

NH 000, 00

System
cover
(alternatively) NH 1, 2, 3

NSG0_00236

Mounting plate

3NP1 fuse switch disconnector for floor mounting

Busbar mounting
Mounting on Siemens 8US
busbar systems with 32/70 mm
cover level

Mounting on Rittal Riline 60


busbar systems with base

70
32

Advantages during operation and service


The optional rear covers for the cable connections guarantee
optimum touch protection even for distribution boards with access from the rear.
Innovative design enables the highest safety for equipment
and personnel.
Fuses can be released and removed using a release shaft.
Lockable and sealable design enables safe working and prevents unauthorized access.

Advantages during installation


Only one device variant is required for cable feeders at
top/bottom and there is no need to intervene in the internal
conducting paths.
One device variant with very high short-circuit values dispenses with having to order and install arc splitters to increase
the electrical values.
On all sizes it is possible to install two CO contacts for indicating the switch position.
All devices feature all-round touch protection.
Box terminals are available for all sizes and shorten the mounting time appreciably.
Snapping on the sizes NH000 and NH00 shortens the mounting time greatly compared to fixing with screws.
The screw-fixing method on sizes NH1, NH2 and NH3 provides for easy positioning and at the same time secure contacting of the larger and heavier device variants.
Small space requirement through compact devices and busbar supports which can be built over.
Device variants for busbar mounting can be converted to
5 mm or 10 mm thick busbars without parts which can be lost
or broken off.

NSG0_00237

Base
Mounting plate
Busbar support
Busbar support

Standards and specifications


The 3NP1 fuse switch disconnectors are compliant with:
IEC 60947-1, EN 60947-1
IEC 60947-3, EN 60947-3

7/90

Siemens LV 10.1 2011

3NP1 fuse switch disconnector for busbar mounting

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Introduction

Technical specifications
Standards

IEC/EN 60439-1

Type

3NP1 123...

3NP1 133...

3NP1 143...

3NP1 153...

3NP1 163...

Rated uninterrupted current Iu

160

160

250

400

630

For fuse links acc. to IEC 60269-1

Size

000

00 and 000

1 and 0

2 and 1

3 and 2

Conventional free-air thermal current


Ith

160

160

250

400

630

50 Hz/60 Hz AC

690

690

690

690

690

DC (3 conducting paths series-connected)

440

440

440

440

440

DC (2 conducting paths series-connected)

220/240

220/240

220/240

220/240

220/240

Rated insulation voltage Ui1)

1000

1000

1000

1000

1000

Rated impulse withstand voltage Uimp

kV

Rated conditional short-circuit current with


fuses

Size/A

000 / 160

00 / 160

1 / 250

2 / 400

3 / 630

Rated current at 500 V / 690 V AC

kA

80

80

80

80

50

Permissible let-through current of the fuses,


peak value

kA

10

15

25

40

50

Short-circuit strength with fuses

Size/A

000 / 160

00 / 160

1 / 250

2 / 400

3 / 630

Rated current at 500 V / 690 V, rms value

kA

120

120

120

100

100

Let-through I2t value

kA2s

56

158

780

2150

5400

Permissible let-through current of the fuses,


peak value

kA

15

23

32

40

60

Rated switching capacity at 500 V AC

kA

17

17

17

Rated operational voltage Ue

Rated making and breaking capacity


At AC-21B, 22B, 23B

400 V AC

160

160

250

400

630

At AC-21B

500 V AC

160

160

250

400

630

At AC-22B

500 V AC

125

160

250

400

630

At AC-23B

500 V AC

40

63

200

315

500

At AC-21 B

690 V AC

160

160

250

400

630

At AC-22B

690 V AC

50

125

250

400

500

At AC-23B

690 V AC

25

35

100

125

200

At DC-21B

240 V DC

160

160

250

400

630

At DC-22B

240 V DC

100

160

250

400

630

At DC-23B

240 V DC

80

100

200

250

400

At DC-21B

440 V DC

100

160

250

400

630

At DC-22B

440 V DC

50

125

200

315

500

At DC-23B

440 V DC

25

63

100

160

250

Capacitor rating

kvar

50

50

50

50

50

Rated current In

72

72

72

72

72

Capacitor switching capacity


At 400 V AC

At 525 V AC
Capacitor rating

kvar

50

50

50

50

50

Rated current In

55

55

55

55

55

Permissible ambient temperature2)

-25 ... +55 for operation, -50 ... +80 during storage
1000

1000

2000

Mechanical endurance, operating cycles

2000

1600

Degree of protection (operator side)


Without molded-plastic masking frame/cable lug
cover

IP30 (switch closed) / IP20 (switch open)


IP40 (switch closed) / IP20 (switch open)

With molded-plastic masking frame/cable lug cover


Power loss of the switch at Ith (plus fuses)

12

23

34

48

Max. conductor cross-section of main conductor


connection
Flat terminals

mm2

--

Up to 95 (M8)

Up to 150 (M10)

Up to 240 (M10)

Up to 300 (M10)

Box terminals

mm2

1.5 ... 50

6 ... 70

70 ... 185

120 ... 240

150 ... 300

Prism terminal

mm2

--

16 ... 95

70 ... 150

120 ... 240

150 ... 300

Saddle terminals

mm2

--

1.5 ... 70

70 ... 150

120 ... 240

150 ... 300

Laminated conductors in box terminal

mm

8x8

9x8

10 x 20

10 x 32

10 x 32

3NP19...-1FA00 auxiliary switch

0.25 (Ith = 5 A)

3NP19...-1FB00 auxiliary switch

0.1 (Ith = 0.1 A)

Rated operational current of auxiliary switch

Permissible mounting positions


1)

Up to pollution degree 2, above this Ui = 690 V.

Vertical and horizontal (no derating)


2)

Only with isolating links; otherwise, please observe specifications of fuse


manufacturer.

Siemens LV 10.1 2011

7/91

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Floor mounting

Selection and ordering data


Rated current Iu

NH type LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For 45 mm cover level


Basic units
Flat terminals
160

00 / 000

3NP1 133-1CA10

1 unit

143

0.730

Box terminals

1001)

000

3NP1 123-1CA20

1 unit

143

0.470

160

00 / 000

3NP1 133-1CA20

1 unit

143

0.730

00 / 000

3NP1 133-1CA11

1 unit

143

1.170

00 / 000

3NP1 133-1CA21

1 unit

143

1.170

3NP1 133-1CA12

1 unit

143

0.870

3NP133-1CA20

With electromechanical MFM fuse monitoring


Flat terminals
160
Box terminals
160

3NP1 133-1CA21

With electronic EFM 10 fuse monitoring


Flat terminals
160

00 / 000

Box terminals
1001)

000

3NP1 123-1CA22

1 unit

143

0.590

160

00 / 000

3NP1 133-1CA22

1 unit

143

0.870

3NP1 133-1CA13

1 unit

143

0.870

3NP1 133-1CA22

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
160

00 / 000

Box terminals
1001)

000

3NP1 123-1CA23

1 unit

143

0.590

160

00 / 000

3NP1 133-1CA23

1 unit

143

0.870

3NP1 133-1CA23
1)

160 A available in combination with feeder terminal 3NP1 923-1BD00

* You can order this quantity or a multiple thereof.

7/92

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Floor mounting
Rated current Iu

NH type LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For 70 mm cover level


Basic units
Flat terminals
250

1 and 0

3NP1 143-1DA10

1 unit

143

2.190

400

2 and 1

3NP1 153-1DA10

1 unit

143

4.210

630

3 and 2

3NP1 163-1DA10

1 unit

143

6.310

250

1 and 0

3NP1 143-1DA20

1 unit

143

2.190

400

2 and 1

3NP1 153-1DA20

1 unit

143

4.660

630

3 and 2

3NP1 163-1DA20

1 unit

143

6.730

Box terminals

3NP1 143-1DA20

With electromechanical MFM fuse monitoring


Flat terminals
250

1 and 0

3NP1 143-1DA11

1 unit

143

2.630

400

2 and 1

3NP1 153-1DA11

1 unit

143

4.650

630

3 and 2

3NP1 163-1DA11

1 unit

143

6.750

250

1 and 0

3NP1 143-1DA21

1 unit

143

2.630

400

2 and 1

3NP1 153-1DA21

1 unit

143

5.100

630

3 and 2

3NP1 163-1DA21

1 unit

143

7.170

Box terminals

3NP1 143-1DA21

With electronic EFM 10 fuse monitoring


Flat terminals
250

1 and 0

3NP1 143-1DA12

1 unit

143

2.330

400

2 and 1

3NP1 153-1DA12

1 unit

143

4.350

630

3 and 2

3NP1 163-1DA12

1 unit

143

6.450

250

1 and 0

3NP1 143-1DA22

1 unit

143

2.330

400

2 and 1

3NP1 153-1DA22

1 unit

143

4.800

630

3 and 2

3NP1 163-1DA22

1 unit

143

6.870

Box terminals

3NP1 143-1DA22

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
250

1 and 0

3NP1 143-1DA13

1 unit

143

2.330

400

2 and 1

3NP1 153-1DA13

1 unit

143

4.350

630

3 and 2

3NP1 163-1DA13

1 unit

143

6.450

250

1 and 0

3NP1 143-1DA23

1 unit

143

2.330

400

2 and 1

3NP1 153-1DA23

1 unit

143

4.800

630

3 and 2

3NP1 163-1DA23

1 unit

143

6.870

Box terminals

3NP1 143-1DA23

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/93

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
For 40 mm busbar system

Selection and ordering data


Rated current Iu

NH type LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For cover level 32 / 70 mm with reach-around protection


for Siemens 8US busbar system and Rittal system without base
for busbar width 12 to 30 mm and thickness 5 mm or 10 mm
Basic units
Flat terminals
160

00 / 000

3NP1 133-1BB10

1 unit

143

0.980

Box terminals

1001)

000

3NP1 123-1BB20

1 unit

143

0.820

160

00 / 000

3NP1 133-1BB20

1 unit

143

0.980

00 / 000

3NP1 133-1BB11

1 unit

143

1.420

00 / 000

3NP1 133-1BB21

1 unit

143

1.420

3NP1 133-1BB12

1 unit

143

1.120

3NP1 133-1BB20

With electromechanical MFM fuse monitoring


Flat terminals
160
Box terminals
160

3NP1 133-1BB21

With electronic EFM 10 fuse monitoring


Flat terminals
160

00 / 000

Box terminals
1001)

000

3NP1 123-1BB22

1 unit

143

0.940

160

00 / 000

3NP1 133-1BB22

1 unit

143

1.120

3NP1 133-1BB13

1 unit

143

1.120

3NP1 133-1BB22

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
160

00 / 000

Box terminals
1001)

000

3NP1 123-1BB23

1 unit

143

0.940

160

00 / 000

3NP1 133-1BB23

1 unit

143

1.120

3NP1 133-1BB23
1)

160 A available in combination with feeder terminal 3NP1 923-1BD00

Note:
Delivered from factory with cable feeder at bottom and convertible by the customer.

* You can order this quantity or a multiple thereof.

7/94

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
For 40 mm busbar system
Rated current Iu

NH type LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For Rittal system with base


for busbar width 12 to 30 mm and thickness 5 mm or 10 mm
Basic units
Flat terminals
160

00 / 000

3NP1 133-1JB10

1 unit

143

0.980

Box terminals
1001)

000

3NP1 123-1JB20

1 unit

143

0.820

160

00 / 000

3NP1 133-1JB20

1 unit

143

0.980

00 / 000

3NP1 133-1JB11

1 unit

143

1.420

00 / 000

3NP1 133-1JB21

1 unit

143

1.420

3NP1 133-1JB12

1 unit

143

1.120

3NP1 133-1JB20

With electromechanical MFM fuse monitoring


Flat terminals
160
Box terminals
160

3NP1 133-1JB21

With electronic EFM 10 fuse monitoring


Flat terminals
160

00 / 000

Box terminals
1001)

000

3NP1 123-1JB22

1 unit

143

0.940

160

00 / 000

3NP1 133-1JB22

1 unit

143

1.120

3NP1 133-1JB13

1 unit

143

1.120

3NP1 133-1JB22

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
160

00 / 000

Box terminals
1001)

000

3NP1 123-1JB23

1 unit

143

0.940

160

00 / 000

3NP1 133-1JB23

1 unit

143

1.120

3NP1 133-1JB23
1)

160 A available in combination with feeder terminal 3NP1 923-1BD00

Note:
Delivered from factory with cable feeder at bottom and convertible by the customer.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/95

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
For 60 mm busbar system

Selection and ordering data


Rated current Iu

NH type LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For cover level 32/70 mm, with reach-around protection


for Siemens 8US busbar system and Rittal Riline60 system without base
for busbar width 12 to 30 mm and thickness 5 mm or 10 mm
Basic units
Flat terminals
160

00 / 000

3NP1 133-1BC10

1 unit

143

0.980

250

1 and 0

3NP1 143-1BC10

1 unit

143

2.850

400

2 and 1

3NP1 153-1BC10

1 unit

143

4.760

630

3 and 2

3NP1 163-1BC10

1 unit

143

6.840

Box terminals

3NP1 133-1BC20

1001)

000

3NP1 123-1BC20

1 unit

143

0.820

160

00 / 000

3NP1 133-1BC20

1 unit

143

0.980

250

1 and 0

3NP1 143-1BC20

1 unit

143

2.850

400

2 and 1

3NP1 153-1BC20

1 unit

143

4.990

630

3 and 2

3NP1 163-1BC20

1 unit

143

7.040

With electromechanical MFM fuse monitoring


Flat terminals
160

00 / 000

3NP1 133-1BC11

1 unit

143

1.420

250

1 and 0

3NP1 143-1BC11

1 unit

143

3.290

400

2 and 1

3NP1 153-1BC11

1 unit

143

5.200

630

3 and 2

3NP1 163-1BC11

1 unit

143

7.280

Box terminals
3NP1 133-1BC21

160

00 / 000

3NP1 133-1BC21

1 unit

143

1.420

250

1 and 0

3NP1 143-1BC21

1 unit

143

3.290

400

2 and 1

3NP1 153-1BC21

1 unit

143

5.430

630

3 and 2

3NP1 163-1BC21

1 unit

143

7.480

With electronic EFM 10 fuse monitoring


Flat terminals
160

00 / 000

3NP1 133-1BC12

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC12

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC12

1 unit

143

4.900

630

3 and 2

3NP1 163-1BC12

1 unit

143

6.980

Box terminals
3NP1 133-1BC22

1001)

000

3NP1 123-1BC22

1 unit

143

0.940

160

00 / 000

3NP1 133-1BC22

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC22

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC22

1 unit

143

5.130

630

3 and 2

3NP1 163-1BC22

1 unit

143

7.180

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
160

00 / 000

3NP1 133-1BC13

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC13

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC13

1 unit

143

4.900

630

3 and 2

3NP1 163-1BC13

1 unit

143

6.980

Box terminals
3NP1 133-1BC23

1)

1001)

000

3NP1 123-1BC23

1 unit

143

0.940

160

00 / 000

3NP1 133-1BC23

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC23

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC23

1 unit

143

5.130

630

3 and 2

3NP1 163-1BC23

1 unit

143

7.180

160 A available in combination with feeder terminal 3NP1 923-1BD00

Note:
Delivered from factory with cable feeder at bottom and convertible by the customer.

* You can order this quantity or a multiple thereof.

7/96

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
For 60 mm busbar system
Rated current Iu

NH type LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For Rittal Riline60 system with base


for busbar width 12 to 30 mm and thickness 5 mm or 10 mm
Basic units
Flat terminals
160

00 / 000

3NP1 133-1JC10

1 unit

143

0.980

250

1 and 0

3NP1 143-1JC10

1 unit

143

2.850

400

2 and 1

3NP1 153-1JC10

1 unit

143

4.760

630

3 and 2

3NP1 163-1JC10

1 unit

143

6.840

Box terminals

3NP1 133-1JC20

1001)

000

3NP1 123-1JC20

1 unit

143

0.820

160

00 / 000

3NP1 133-1JC20

1 unit

143

0.980

250

1 and 0

3NP1 143-1JC20

1 unit

143

2.850

400

2 and 1

3NP1 153-1JC20

1 unit

143

4.990

630

3 and 2

3NP1 163-1JC20

1 unit

143

7.040

With electromechanical MFM fuse monitoring


Flat terminals
160

00 / 000

3NP1 133-1JC11

1 unit

143

1.420

250

1 and 0

3NP1 143-1JC11

1 unit

143

3.290

400

2 and 1

3NP1 153-1JC11

1 unit

143

5.200

630

3 and 2

3NP1 163-1JC11

1 unit

143

7.280

Box terminals
3NP1 133-1JC21

160

00 / 000

3NP1 133-1JC21

1 unit

143

1.420

250

1 and 0

3NP1 143-1JC21

1 unit

143

3.290

400

2 and 1

3NP1 153-1JC21

1 unit

143

5.430

630

3 and 2

3NP1 163-1JC21

1 unit

143

7.480

With electronic EFM 10 fuse monitoring


Flat terminals
160

00 / 000

3NP1 133-1JC12

1 unit

143

1.120

250

1 and 0

3NP1 143-1JC12

1 unit

143

2.990

400

2 and 1

3NP1 153-1JC12

1 unit

143

4.900

630

3 and 2

3NP1 163-1JC12

1 unit

143

6.980

Box terminals
3NP1 133-1JC22

1001)

000

3NP1 123-1JC22

1 unit

143

0.940

160

00 / 000

3NP1 133-1JC22

1 unit

143

1.120

250

1 and 0

3NP1 143-1JC22

1 unit

143

2.990

400

2 and 1

3NP1 153-1JC22

1 unit

143

5.130

630

3 and 2

3NP1 163-1JC22

1 unit

143

7.180

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
160

00 / 000

3NP1 133-1JC13

1 unit

143

1.120

250

1 and 0

3NP1 143-1JC13

1 unit

143

2.990

400

2 and 1

3NP1 153-1JC13

1 unit

143

4.900

630

3 and 2

3NP1 163-1JC13

1 unit

143

6.980

Box terminals
3NP1 133-1JC23

1)

1001)

000

3NP1 123-1JC23

1 unit

143

0.940

160

00 / 000

3NP1 133-1JC23

1 unit

143

1.120

250

1 and 0

3NP1 143-1JC23

1 unit

143

2.990

400

2 and 1

3NP1 153-1JC23

1 unit

143

5.130

630

3 and 2

3NP1 163-1JC23

1 unit

143

7.180

160 A available in combination with feeder terminal 3NP1 923-1BD00

Note:
Delivered from factory with cable feeder at bottom and convertible by the customer.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/97

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH000


Connection methods
Feeder terminals, 16 ... 95 mm2
(1 set = 3 units)

3NP1 923-1BD00

1 unit

143

0.097

3-way terminal, 3 x 2.5 ... 16 mm2,


for box terminal
(1 set= 3 units)

3NP1 923-1BE20

1 unit

143

0.134

Covering caps
For 1 blank space on a three-phase busbar
(1 set = 20 units)

3NP1 923-1BF10

1 unit

143

0.012

For 2 x NH000

3NP1 923-1BF20

1 unit

143

0.268

For 3x NH000

3NP1 923-1BF30

1 unit

143

0.436

For 4x NH000

3NP1 923-1BF40

1 unit

143

0.650

Connection piece, Iu = max. 225 A


For 3-phase busbars
(1 set = 3 units)

3NP1 923-1BF50

1 unit

143

0.263

Auxiliary conductor connection, 0.25 ... 1 mm2


For box terminal
(1 set= 3 units)

3NP1 923-1BG40

1 unit

143

0.004

3NP1 923-1BD00

7
3NP1 923-1BE20

3NP1 923-1BF10
3-phase busbar
Iu = max. 225 A
(1 set = 5 units)
3NP1 933-1BF30

3NP1 933-1BF50

* You can order this quantity or a multiple thereof.

7/98

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH000 (continued)


Device covers, auxiliary switches
Reach-around protection for busbar mounting
(1x top, 1x bottom)
For System Siemens 8US

3NP1 923-1CA10

1 unit

143

0.048

For System Rittal

3NP1 923-1CA20

1 unit

143

0.053

Cable connection covers


Only for busbar systems 40 mm / 60 mm, top and bottom

3NP1 923-1CB00

1 unit

143

0.039

Masking frame supports


(1 set = 2 units)

3NP1 923-1CF00

1 unit

143

0.012

3NP1 923-1DA00

1 unit

143

0.049

3NP1 923-1EA00

1 unit

143

0.009

1 CO

3NP1 920-1FA00

1 unit

143

0.012

1 CO contact, solid-state compatible

3NP1 920-1FB00

1 unit

143

0.012

Standard

3NP1 923-1GA00

1 unit

143

0.124

With electronic EFM 10 fuse monitoring

3NP1 923-1GB20

1 unit

143

0.551

With electronic EFM 20 fuse monitoring and


line monitoring

3NP1 923-1GB30

1 unit

143

0.573

With electronic EFM 25 fuse monitoring and


line monitoring

3NP1 923-1GB50

1 unit

143

0.573

3NP1 900-1HA00

1 unit

143

0.006

3NP1 923-1CA10

3NP1 923-1CB00

3NP1 923-1CF00
System masking frames
Dimensions (H x W) 215 x 130 mm

3NP1 923-1DA00
Fixing kits
For 1 standard mounting rail

3NP1 923-1EA00
Auxiliary switches

3NP1 920-1FA00
Fuse carriers

3NP1 923-1GA00
Locking devices
(1 set = 10 units)
3NP1 900-1HA00

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/99

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH00


Connection
Saddle terminals, 1.5 ... 70 mm2
For flat connection
(1 set= 3 units)

3NP1 933-1BA00

1 unit

143

0.081

Prism terminal single, 35... 95 mm2


For flat connection
(1 set= 3 units)

3NP1 933-1BB10

1 unit

143

0.121

Connection module, 6 ... 70 mm2


For flat terminals
For 32 mm cover level with box terminal

3NP1 933-1BC00

1 unit

143

0.145

3-way terminal, 3 x 2.5 ... 16 mm2


For flat terminals
(1 set = 3 units)

3NP1 933-1BE10

1 unit

143

0.087

3-way terminal, 3 x 2.5 ... 16 mm2


For box terminal
(1 set= 3 units)

3NP1 923-1BE20

1 unit

143

0.134

Auxiliary conductor connection, 0.25 ... 1 mm2


For flat connection
(1 set= 3 units)

3NP1 933-1BG10

1 unit

143

0.006

Auxiliary conductor connection, 0.25 ... 1 mm2


For prism terminal
(1 set= 3 units)

3NP1 933-1BG30

1 unit

143

0.004

Auxiliary conductor connection, 0.25 ... 1 mm2


For box terminal
(1 set= 3 units)

3NP1 933-1BG40

1 unit

143

0.006

3NP1 933-1BA00

3NP1 933-1BB10

3NP1 933-1BC00

3NP1 933-1BE10

3NP1 923-1BE20

3NP1 933-1BG10

3NP1 933-1BG30

3NP1 933-1BG40

* You can order this quantity or a multiple thereof.

7/100

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH00 (continued)


Device covers, auxiliary switches
Reach-around protection for busbar mounting
(1x at top, 1x at bottom)

3NP1 933-1CA10

For System Siemens 8US

3NP1 933-1CA10

1 unit

143

0.058

For System Rittal

3NP1 933-1CA20

1 unit

143

0.044

Cable connection covers (at top and bottom)


For flat terminal

3NP1 933-1CB00

1 unit

143

0.045

Cable connection covers with rear reach-around protection in case of busbar mounting (at top and bottom)
For flat terminal

3NP1 933-1CC00

1 unit

143

0.093

3NP1 933-1CB00

3NP1 933-1CC00
Cable connection covers with rear reach-around
A
protection in case of busbar mounting (at top and bottom)
For flat terminal

3NP1 933-1CD00

1 unit

143

0.079

3NP1 933-1CF00

1 unit

143

0.012

3NP1 933-1DA00

1 unit

143

0.024

3NP1 933-1EB00

1 unit

143

0.009

1 CO

3NP1 930-1FA00

1 unit

143

0.012

1 CO contact, solid-state compatible

3NP1 930-1FB00

1 unit

143

0.012

Standard

3NP1 933-1GA00

1 unit

143

0.165

With electromechanical MFM fuse monitoring

3NP1 933-1GB10

1 unit

143

1.293

With electronic EFM 10 fuse monitoring

3NP1 933-1GB20

1 unit

143

0.589

With electronic EFM 20 fuse monitoring


and line monitoring

3NP1 933-1GB30

1 unit

143

0.611

With electronic EFM 25 fuse monitoring and


line monitoring

3NP1 933-1GB50

1 unit

143

0.611

3NP1 900-1HA00

1 unit

143

0.006

3NP1 933-1CD00
Masking frame supports
(1 set = 2 units)

3NP1 933-1CF00
System masking frames
Dimensions (H x W) 215 x 130 mm
Fixing kits
For 2 standard mounting rails 125/150 mm

3NP1 933-1EB00
Auxiliary switches

3NP1 930-1FB00
Fuse carriers

3NP1 933-1GB10

Locking devices
(1 set = 10 units)

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/101

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH1


Connection
Saddle terminals, 70 ... 150 mm2
For flat terminal
(1 set = 3 units)

3NP1 943-1BA00

1 unit

143

0.144

Prism terminal single, 70... 150 mm2


For flat terminal
(1 set = 3 units)

3NP1 943-1BB10

1 unit

143

0.270

Prism terminals double, 2 x 35 ... 70 mm2


For flat terminal
(1 set = 3 units)

3NP1 943-1BB20

1 unit

143

0.311

Auxiliary conductor connection, 0.25 ... 1 mm2


For flat terminal
(1 set = 3 units)

3NP1 943-1BG10

1 unit

143

0.009

Auxiliary conductor connection, 0.25 ... 1 mm2


For saddle-type or prism terminals
(1 set = 3 units)

3NP1 943-1BG30

1 unit

143

0.004

Auxiliary conductor connection, 0.25 ... 1 mm2


For box terminal
(1 set= 3 units)

3NP1 943-1BG40

1 unit

143

0.014

3NP1 943-1BA00

3NP1 943-1BB10

7
3NP1 943-1BB20

3NP1 943-1BG10

3NP1 943-1BG30

3NP1 943-1BG40

* You can order this quantity or a multiple thereof.

7/102

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH1 (continued)


Device covers, auxiliary switches
Reach-around protection for busbar mounting
(1x at top, 1x at bottom)
3NP1 943-1CA10

For System Siemens 8US

3NP1 943-1CA10

1 unit

143

0.024

For System Rittal

3NP1 943-1CA20

1 unit

143

0.034

Cable connection covers (at top and bottom)

3NP1 943-1CB00

1 unit

143

0.172

Cable connection covers with rear reach-around


protection (at top and bottom)

3NP1 943-1CD00

1 unit

143

0.277

3NP1 943-1CB00

7
3NP1 943-1CD00
Masking frame supports (1 set = 2 units)

3NP1 943-1CF00

1 unit

143

0.026

3NP1 943-1DA00

1 unit

143

0.092

3NP1 943-1EB00

1 unit

143

0.017

1 CO

3NP1 940-1FA00

1 unit

143

0.018

1 CO contact, solid-state compatible

3NP1 940-1FB00

1 unit

143

0.018

Standard

3NP1 943-1GA00

1 unit

143

0.602

With electromechanical MFM fuse monitoring

3NP1 943-1GB10

1 unit

143

1.726

With electronic EFM 10 fuse monitoring

3NP1 943-1GB20

1 unit

143

1.022

With electronic EFM 20 fuse monitoring


and line monitoring

3NP1 943-1GB30

1 unit

143

1.044

With electronic EFM 25 fuse monitoring and


line monitoring

3NP1 943-1GB50

1 unit

143

1.044

3NP1 900-1HA00

1 unit

143

0.006

System masking frames


Dimensions (H x W) 375 x 220 mm
Fixing kits
For 2 standard mounting rails 125/150 mm

3NP1 943-1EB00
Auxiliary switches

3NP1 940-1FA00
Fuse carriers

3NP1 943-1GB20
Locking devices
(1 set = 10 units)

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/103

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH2


Connection
Saddle terminals, 120 ... 240 mm2
For flat terminal
(1 set = 3 units)

3NP1 953-1BA00

1 unit

143

0.187

Prism terminal single, 120... 240 mm2


For flat terminal
(1 set = 3 units)

3NP1 953-1BB10

1 unit

143

0.420

Prism terminals double, 2 x 70 ... 120 mm2


For flat terminal
(1 set = 3 units)

3NP1 953-1BB20

1 unit

143

0.473

Auxiliary conductor connection, 0.25 ... 1 mm2


For flat terminal
(1 set = 3 units)

3NP1 943-1BG10

1 unit

143

0.009

Auxiliary conductor connection, 0.25 ... 1 mm2


For saddle-type or prism terminals
(1 set = 3 units)

3NP1 953-1BG30

1 unit

143

0.006

Auxiliary conductor connection, 0.25 ... 1 mm2


For box terminals
(1 set = 3 units)

3NP1 953-1BG40

1 unit

143

0.029

For System Siemens 8US

3NP1 953-1CA10

1 unit

143

0.028

For System Rittal

3NP1 953-1CA20

1 unit

143

0.038

Cable connection covers (at top and bottom)

3NP1 953-1CB00

1 unit

143

0.242

Cable connection covers


With rear reach-around protection (at top and bottom)

3NP1 953-1CD00

1 unit

143

0.362

Masking frame supports (1 set = 2 units)

3NP1 943-1CF00

1 unit

143

0.026

3NP1 953-1DA00

1 unit

143

0.097

1 CO

3NP1 940-1FA00

1 unit

143

0.018

1 CO contact, solid-state compatible

3NP1 940-1FB00

1 unit

143

0.018

Standard

3NP1 953-1GA00

1 unit

143

0.754

With electromechanical MFM fuse monitoring

3NP1 953-1GB10

1 unit

143

1.797

With electronic EFM 10 fuse monitoring

3NP1 953-1GB20

1 unit

143

1.093

With electronic EFM 20 fuse monitoring and


line monitoring

3NP1 953-1GB30

1 unit

143

1.115

With electronic EFM 25 fuse monitoring and


line monitoring

3NP1 953-1GB50

1 unit

143

1.115

3NP1 900-1HA00

1 unit

143

0.006

3NP1 953-1BA00

3NP1 953-1BB10

7
3NP1 953-1BB20

3NP1 943-1BG10

3NP1 953-1BG30

3NP1 953-1BG40

Device covers, auxiliary switches


Reach-around protection for busbar mounting
(1x at top, 1x at bottom)
3NP1 953-1CA10

3NP1 953-1CB00

System masking frames


Dimensions (H x W) 375 x 245 mm
Auxiliary switches

3NP1 940-1FA00
Fuse carriers

3NP1 953-1GB30
Locking devices
(1 set = 10 units)

* You can order this quantity or a multiple thereof.

7/104

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP1 Fuse Switch Disconnectors up to 630 A
Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For size NH3


Connection
Saddle terminals, 150 ... 300 mm2
For flat terminal
(1 set = 3 units)

3NP1 963-1BA00

1 unit

143

0.210

Prism terminal single, 150... 300 mm2


For flat terminal
(1 set = 3 units)

3NP1 963-1BB10

1 unit

143

0.643

Prism terminals double, 2 x 150 ... 185 mm2


For flat terminal
(1 set = 3 units)

3NP1 963-1BB20

1 unit

143

0.681

Auxiliary conductor connection, 0.25 ... 1 mm2


For flat terminal
(1 set = 3 units)

3NP1 943-1BG10

1 unit

143

0.009

Auxiliary conductor connection, 0.25 ... 1 mm2


For saddle-type or prism terminals
(1 set = 3 units)

3NP1 953-1BG30

1 unit

143

0.006

Auxiliary conductor connection, 0.25 ... 1 mm2


For box terminals
(1 set = 3 units)

3NP1 953-1BG40

1 unit

143

0.029

For System Siemens 8US

3NP1 963-1CA10

1 unit

143

0.032

For System Rittal

3NP1 963-1CA20

1 unit

143

0.043

Cable connection covers (at top and bottom)

3NP1 963-1CB00

1 unit

143

0.269

Cable connection cover


With rear reach-around protection (at top and bottom)

3NP1 963-1CD00

1 unit

143

0.411

Masking frame supports (1 set = 2 units)

3NP1 943-1CF00

1 unit

143

0.026

3NP1 963-1DA00

1 unit

143

0.116

1 CO

3NP1 940-1FA00

1 unit

143

0.018

1 CO contact, solid-state compatible

3NP1 940-1FB00

1 unit

143

0.018

Standard

3NP1 963-1GA00

1 unit

143

0.825

With electromechanical MFM fuse monitoring

3NP1 963-1GB10

1 unit

143

1.966

With electronic EFM 10 fuse monitoring

3NP1 963-1GB20

1 unit

143

1.262

With electronic EFM 20 fuse monitoring and


line monitoring

3NP1 963-1GB30

1 unit

143

1.284

With electronic EFM 25 fuse monitoring and


line monitoring

3NP1 963-1GB50

1 unit

143

1.284

3NP1 900-1HA00

1 unit

143

0.006

3NP1 963-1BA00

3NP1 963-1BB10

3NP1 963-1BB20

3NP1 943-1BG10

3NP1 953-1BG30

3NP1 953-1BG40

Device covers, auxiliary switches


Reach-around protection for busbar mounting
(1x at top, 1x at bottom)
3NP1 963-1CA10

3NP1 963-1CB00

System masking frames


Dimensions (H x W) 375 x 290 mm
Auxiliary switches

3NP1 940-1FA00
Fuse carriers

3NP1 963-1GB50

Locking devices
(1 set = 10 units)
* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/105

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Introduction

Overview

Application
The SENTRON 3NP5 fuse switch disconnectors are ideally
suited for surface mounting and installation in distribution
boards (e.g. ALPHA, SIKUS), meter cabinets
(e.g. ALPHA 400-ZS), and molded-plastic distribution systems
such as 8HP.
The possibility of mounting them onto a range of different busbar
systems allows their very diverse implementation in switchgear
cabinet and control engineering.
The SENTRON 3NP5 fuse switch disconnectors are ideal for
operation in combination with other switching devices, for example in capacitor modules for reactive-power compensation.

3NP5 0

In conjunction with semiconductor protection fuses (e.g. SITOR),


these are used for the effective protection of frequency converters and soft starters.

3NP5 2
3NP5 4

7
3NP5 fuse switch disconnector range

SENTRON 3NP5 fuse switch disconnectors are controls for the


occasional manual switching/isolating of loads and distribution
boards. They are able to switch on, control and switch off the
specified rated current (including a specific overload).
With the SENTRON 3NP5 fuse switch disconnectors, all poles of
downstream electric loads can be safely disconnected from the
system under load.

7/106

Siemens LV 10.1 2011

The SENTRON 3NP5 fuse switch disconnectors are suitable for


use in any climate and comply with standards IEC 60947-1 and
IEC 60947-3.
In addition, the SENTRON 3NP5 series of fuse switch disconnectors complies with the requirements of BS 5419 and is also approved for operation in marine applications.
All SENTRON 3NP5 fuse switch disconnectors can be sealed as
standard (or can be sealed through accessories).

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Introduction

Technical specifications
Standards

IEC 60947-1, IEC 60947-3


3NP50

3NP52

3NP53

3NP54

Rated uninterrupted current Iu

160

250

400

630

For fuse links acc. to IEC 60269-1

Size

00

1 and 0

2 and 1

3 and 2

Conventional free-air thermal current Ith

160

250

400

630

Rated operational voltage Ue


50/60 Hz AC
DC

V
V

690
440 (3 conducting paths series-connected),
220 (2 conducting paths series-connected and with fuse monitoring
through 3RV)

Rated insulation voltage Ui

6901)

6901)

6901)

6901)

Rated impulse withstand voltage Uimp

kV

Rated conditional short-circuit current


with fuses (by fast switch on)
With fuse links
Rated current
At 500 V AC (rms value)
Permissible let-through current of the fuses (peak value)

Size/A
kA
kA

00/160
50
15

1/250
50
25

2/400
50
40

3/630
50
50

Short-circuit strength with fuses (with closed disconnector)


With fuse links
Rated current
At 500 V AC (rms value)
Maximum permissible let-through I2t value
Permissible let-through current of the fuses (peak value)

Size/A
kA
kA2s
kA

00/160
100
223
23

1/250
100
780
32

2/400
50
2150
40

3/630
50
5400
60

Rated short-circuit making capacity with isolating links2)


At 500 V AC (peak value)

Size
kA

00
6

1
17

2
17

3
17

A
A

00
1600
160

1
2500
250

0
1600
160

2
4000
400

1
2500
250

3
5040
630

2
4000
400

A
A

1300
160

2500
250

1600
160

4000
400

2500
250

5040
630

4000
400

A
A
A

800
160
100

1280
250
160

1000
160
125

2520
400
315

1600
250
200

3200
630
400

2520
400
315

At 220 (440) V DC, with 2 (3) conducting paths series-connected and fuse links:
Breaking current Ic (L/R = 15 ms)
A
A
Rated operational current Ie at DC-23B

640
160

1000
250

640
160

1600
250

1600
250

2520
630

1600
400

Capacitor switching capacity


Capacitor rating at 400 V AC
Rated current In at 525 V AC
Capacitor rating
Rated current In

kvar
A
kvar
A

80
116
100
110

90
130
125
137

Permissible ambient temperature

-25 ... +55 for operation4), -50 ... +80 when stored

Type

Rated making and breaking capacity2) (infeed from top or bottom)3)


Size
Breaking current Ic (p.f. = 0.35) at 400 V AC, with fuse links, rms value,
Rated operational current Ie at AC-21B, AC-22B, AC-23B at 500 V AC, with fuse
links
Breaking current Ic (p.f. = 0.35) (rms. value)
Rated operational current Ie at AC-21B, AC-22B, AC-23B at 690 V AC, with fuse
links
Breaking current Ic (p.f. = 0.35) (rms. value)
Rated operational current Ie at AC-21B, AC-22B
Rated operational current Ie at AC-23B

Mechanical endurance, operating cycles

1600

Degree of protection
Without molded-plastic masking frame
With molded-plastic masking frame with closed fuse carrier on the operator side
With molded-plastic masking frame with open fuse carrier

IP005)
IP30
IP10

150
216
200
220

250
361
300
330

Power loss of the switch at Ith (without power loss of fuse links)
Without busbar adapter

7.8 (16.3)6)

7.5

15

39

Main conductor connections


Cable lug, max. conductor cross-section (stranded)
Busbar
Clamp terminals

mm2
mm
mm2

2.5 ... 120


16 ... 22
2.5 ... 50

6 ... 150
22 ... 30
35 ... 120

6 ... 240
22 ... 30
--

6 ... 2 240
22 ... 30
--

16/6
A 6.3 ... 0.8

Auxiliary switch 1 NO + 1 NC (accessories)


(the same voltage potential must be applied to both NO and NC contact)
At 50 Hz/60 Hz to 400 V AC, rated operational current Ie at AC-12/AC-15 A
Flat terminal (DIN 46244)
Permissible mounting positions

Vertical or horizontal
(partially reduced switching capacity with horizontal mounting)

Signaling contact for solid-state fuse monitoring


Rated operational current Ie
At 250 V, DC-13
At 240 V, AC-15
Thermal free-air rated current Ith

2 NO + 1 NC
A
A
A

0.27
1.5
5

1)

When observing degree of pollution 2 (instead of 3) operation is also possible up to Ui = 1000 V.

4)

When using isolating links. If using fuse links, please observe specifications of fuse manufacturer.

2)

Rated making and breaking current according to IEC 60947-3


Rated making current
I = 10 Ie (AC-23); 3 Ie (AC-22); 1.5 Ie (AC-21)
Rated breaking current
Ie = 8 Ie (AC-23); 3 Ie (AC-22); 1.5 Ie (AC-21).

5)

For 3NP52 with terminal clamp connection, degree of protection IP10.

6)

With busbar adapter.

3)

When using electronic fuse monitoring, infeed must be from the top.

Siemens LV 10.1 2011

7/107

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Floor mounting

Selection and ordering data


Rated Connection types
uninter- (on both sides)
rupted
current
Iu
Connection For conductor crosssection

For LV
HRC fuse
links
acc. to
IEC 60269

For
isolating
links

Auxiliary DT
switch on
switch
disconnectors

Degree of protection IP00,


without fuse links,
without isolating links,
with terminal screws

NH size

NH
size

Version

Order No.

1)

PU
PS*/
(UNIT, P. unit
SET,
M)

PG

Price
per PU

mm2

Weight
per PU
approx.

kg

Completely compartmentalized, with high speed closing features


00 and
000

00

Without4) }
1 NO + B
1 NC

3NP50 60-0CA00
3NP50 60-0CA10

1
1

1 unit
1 unit

103
103

1.608
1.650

Clamp
terminals

1 conductor 00 and
2.5 ... 50 or 000
2 conductors
1 2.5 ... 50
1 2.5 ... 35

00

Without4) A
1 NO + B
1 NC

3NP50 60-0CB00
3NP50 60-0CB10

1
1

1 unit
1 unit

103
103

1.739
1.748

Flat
terminals

6 ... 1505)

1 and 0

Without
1 NO +
1 NC

}
A

3NP52 60-0CA00
3NP52 60-0CA10

1
1

1 unit
1 unit

103
103

5.475
5.491

Clamp
terminals

35 ... 120

1 and 0

Without
1 NO +
1 NC

C
B

3NP52 60-0CB00
3NP52 60-0CB10

1
1

1 unit
1 unit

103
103

5.605
5.814

400

Flat
terminals

6 ... 2405)

2 and 1

Without
1 NO +
1 NC

}
A

3NP53 60-0CA00
3NP53 60-0CA10

1
1

1 unit
1 unit

103
103

6.532
6.551

630

Flat
terminals

6 ... 2 2405) 3 and 2

Without
1 NO +
1 NC

}
B

3NP54 60-0CA00
3NP54 60-0CA10

1
1

1 unit
1 unit

103
103

7.945
7.958

160

Flat
2.5 ... 1503)
connector2)

3NP50 60-0CA00
250

3NP52 60-0CA00

3NP53 60-0CA00

3NP54 60-0CA00
1)

For LV HRC fuse links, see chapter 5 "Fuse Systems".

2)

For 3NP50 60 with flat connectors, appropriate 3NY1 106 cable lug covers
must be used to provide finger-safe cover, according to EN 50274
(see Accessories).

3)

According to DIN 46234 or 16 mm2 ... 95 mm2 according to DIN 46235


(use M10 cable lug as necessary).

4)

If auxiliary switch is retrofitted, additional drill holes are required on the


switch.

5)

According to DIN 46234 or DIN 46235; with cable lug to DIN 46235:
Min. conductor cross-section 16 mm2 (use M12 cable lug if necessary).

* You can order this quantity or a multiple thereof.

7/108

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
For 40 mm busbar system

Selection and ordering data


Rated
uninterrupted
current
Iu

Connection types
(on both sides)

For LV HRC
fuse links
acc. to
DIN 436201)

For isolating
links

Connection

NH size

NH size Version

For conductor crosssection

Auxiliary
switch on
switch disconnectors

DT

Degree of protection IP00,


without fuse links,
without isolating links,
with terminal screws
Order No.

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Price
per PU

mm2

Weight
per PU
approx.

kg

Completely compartmentalized, with high speed closing features2)


Busbars with a width of 12 mm and thickness of 5 mm or 10 mm
160

Flat
terminals

2.5 ... 1503)


Connection
at bottom

00 and 000

Without
1 NO +
1 NC

C
B

3NP50 65-1CF00
3NP50 65-1CF10

1
1

1 unit
1 unit

103
103

2.380
2.370

Clamp
terminal

1 conductor 00 and 000


2.5 ... 50 or
2 conductors
1 2.5 ... 50
1 2.5 ... 35
bottom connection

Without
1 NO +
1 NC

B
B

3NP50 65-1CG00
3NP50 65-1CG10

1
1

1 unit
1 unit

103
103

2.433
2.437

1)

For LV HRC fuse links, see chapter 5 "Fuse Systems".

2)

For accessories and more devices on busbar systems, see "Accessories".

3)

According to DIN 46234 or 16 ... 95 mm2 according to DIN 46235


(use M10 cable lug as necessary).

For 60 mm busbar system

Overview
Note:
For switch versions "For installation in any distribution board" and
busbar adapters see page 7/117.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/109

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
With fuse monitoring

Selection and ordering data


Fuse monitoring by motor starter protectors
Floor mounting
Rated
uninterrupted
current
Iu

Connection types
(on both sides)

Auxiliary switches

Connection

On switch On MSP
disconnector

For LV HRC
fuse links
acc. to
1)
For conduc- DIN 43620
tor crosssection

mm

NH size

Version

DT

Degree of protection IP00,


without fuse links,
without isolating links,
with terminal screws
Order No.

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Price
per PU

Version

kg

Completely compartmentalized, with high speed closing features


with fuse monitoring by SIRIUS motor starter protectors
With plug-in connection of the auxiliary switch connecting cable
(length approx. 1 m) to the motor starter protector
160

Flat
2.5 ... 1503) 00 and 000
terminals
2)

Clamp
1 conductor 00 and 000
terminals 2.5... 50
2 conductor
1 2.5 ... 50
1 2.5 ... 35
250

Flat
6 ... 1504)
terminals

Clamp
35 ... 120
terminals

1 and 0

1 and 0

3NP52 60-0EA86
400

Flat
6 ... 2404)
terminals

2 and 1

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

3NP50 60-0EA86

1 unit

103

2.484

3NP50 60-0EA26

1 unit

103

2.550

3NP50 60-0EB86

1 unit

103

2.616

3NP50 60-0EB26

1 unit

103

2.650

3NP52 60-0EA86

1 unit

103

6.014

3NP52 60-0EA26

1 unit

103

6.867

3NP52 60-0EB86

1 unit

103

7.095

3NP52 60-0EB26

1 unit

103

6.659

3NP53 60-0EA86

1 unit

103

7.083

3NP53 60-0EA26

1 unit

103

5.410

3NP54 60-0EA86

1 unit

103

8.462

3NP54 60-0EA26

1 unit

103

9.233

3NP53 60-0EA86
630

Flat
6 ... 2
terminals 2404)

3 and 2

3NP54 60-0EA86
1)

For LV HRC fuse links, see chapter 5 "Fuse Systems".

2)

For 3NP50 60 with flat connectors, appropriate 3NY1 106 cable lug covers
must be used to provide finger-safe cover, according to EN 50274
(see Accessories).

3)

According to DIN 46234 or 16 ... 95 mm2 according to DIN 46235


(use M10 cable lug as necessary).

4)

According to DIN 46234 or DIN 46235, with cable lug to DIN 46235:
Min. conductor cross-section 16 mm2 (use M12 cable lug if necessary).

* You can order this quantity or a multiple thereof.

7/110

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
With fuse monitoring
For 40 mm busbar system
Rated
uninterrupted
current
Iu

Connection types
(on both sides)
Connection

For conductor crosssection


mm2

For LV HRC
fuse links
acc. to
DIN 436201)

Auxiliary switches

NH size

Version

DT

On switch On MSP
disconnector

Degree of protection IP00,


without fuse links,
without isolating links,
with terminal screws
Order No.

Version

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Price
per PU

Weight
per PU
approx.

kg

Completely compartmentalized, with high speed closing features with fuse


monitoring by SIRIUS motor starter protectors 2)
Busbars with a width of 12 mm and thickness of 5 mm or 10 mm
160

Flat
2.5 ... 1503)
terminals
Connection
at bottom

00 and 000

Clamp
1 conductor 00 and 000
terminals
2.5 ... 50
2 conductors
1 2.5 ... 50
1 2.5 ... 35
Connection
at bottom

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1 NO +
1 NC
1 NO +
1 NC

1 NO +
1 NC
2 NO

1)

For LV HRC fuse links, see chapter 5 "Fuse Systems".

2)

For accessories and more devices on busbar systems, see chapter 10


"Busbar Systems".

3)

According to DIN 46234 or 16 mm2 ... 95 mm2 according to DIN 46235


(use M10 cable lug as necessary).

3NP50 65-1EF86

1 unit

103

2.908

3NP50 65-1EF26

1 unit

103

2.950

3NP50 65-1EG86

1 unit

103

3.020

3NP50 65-1EG26

1 unit

103

2.973

For 60 mm busbar system


Note:
For switch versions "For installation in any distribution board" and
busbar adapters see page 7/117.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/111

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
With fuse monitoring
Fuse monitoring by electronic fuse monitoring device
Floor mounting
Rated
uninterrupted
current
Iu

Connection types
(on both sides)
Connec- For contion
ductor
crosssection
mm2

For LV HRC Auxiliary switches


fuse links
acc. to
On
On the
DIN 436201) switch
fuse
discon- monitor
nector
NH size

Version

DT

Degree of protection IP00,


without fuse links,
without isolating links,
with terminal screws
Order No.

PU
(UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Price
per PU

Version

kg

Completely compartmentalized, with high speed closing feature,


with electronic fuse monitoring (self-powered), open-circuit principle
For rated operational voltages Ue from 400 V to 500 V AC,
infeed must come from above!
With plug-in connection for connecting cables from auxiliary switches
(approx. 1 m long) to the fuse monitoring device, status indicator:
green LED illuminated, fault indication: green LED flashing,
fuse failure: red LED (display per phase)
160

Flat
terminals 2)

2.5 ...
1203)

00 and 000

1 NO +
1 NC

2 NO +
1 NC

3NP50 60-0HA13

1 unit

103

2.375

Clamp
1 con00 and 000
terminals ductors:
2.5 ... 50

1 NO +
1 NC

2 NO +
1 NC

3NP50 60-0HB13

1 unit

103

2.500

2 conductors:
1
2.5 ... 50
1
2.5 ... 35

3NP50 60-0HA13
250

Flat
6 ... 1504) 1 and 0
terminals

1 NO +
1 NC

2 NO +
1 NC

3NP52 60-0HA13

1 unit

103

5.865

400

Flat
6 ... 2404) 2 and 1
terminals

1 NO +
1 NC

2 NO +
1 NC

3NP53 60-0HA13

1 unit

103

6.951

630

Flat
6 ...2404) 3 and 2
terminals

1 NO +
1 NC

2 NO +
1 NC

3NP54 60-0HA13

1 unit

103

8.513

3NP52 60-0HA13

3NP53 60-0HA13

3NP54 60-0HA13
1)

For LV HRC fuse links, see chapter 5 "Fuse Systems".

2)

For 3NP50 60 with flat connectors, appropriate 3NY1 106 cable lug covers
must be used to provide finger-safe cover, according to EN 50274
(see Accessories).

3)

According to DIN 46234 or 16 mm2 ... 95 mm2 according to DIN 46235


(use M10 cable lug as necessary).

4)

According to DIN 46234 or DIN 46235; with cable lug to DIN 46235:
Min. conductor cross-section 16 mm2 (use M12 cable lug if necessary).

* You can order this quantity or a multiple thereof.

7/112

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
With fuse monitoring
For 40 mm busbar system
Rated
uninterrupted
current
Iu

Connection types
(on both sides)
Connec- For contion
ductor
crosssection
mm2

For LV HRC Auxiliary switches


fuse links
acc. to
On
On the
DIN 436201) switch
fuse
discon- monitor
nector
NH size

Version

DT

Degree of protection IP00,


without fuse links,
without isolating links,
with terminal screws
Order No.

PU
PS*/
(UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.

Price
per PU

Version

kg

Completely compartmentalized, with high speed closing feature,


with electronic fuse monitoring (self-powered), open-circuit principle
For rated operational voltages Ue from 400 V to 500 V AC, infeed
must come from above!
Busbars with a width of 12 mm and thickness of 5 mm or 10 mm
160

Flat
terminals

2.5 ...
1202)
Connection at
bottom

00 and 000

1 NO +
1 NC

2 NO +
1 NC

3NP50 65-1HF13

1 unit

103

2.776

7
3NP50 65-1HF13
1)

For LV HRC fuse links, see chapter 5 "Fuse Systems".

2)

According to DIN 46234 or 16 mm2 ... 95 mm2 according to DIN 46235


(use M10 cable lug as necessary).

For 60 mm busbar system


Note:
For switch versions "For installation in any distribution board" and
busbar adapters see page 7/117. .

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/113

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Accessories

Selection and ordering data


Version

For fuse switch


disconnectors

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Fuse carriers
3NP50 6.-.C..0
3NP52 60-.C..0
3NP53 60-.C..0
3NP54 60-.C..0

B
B
B
B

3NY1 074
3NY1 371
3NY1 372
3NY1 373

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

0.620
0.263
1.510
1.690

With fuse monitoring by 3RV1 MSPs


(with auxiliary switch 1 NO + 1 NC),
with plug-in connection,
without connector and connecting cable

3NP50 6.-.E..6
3NP52 60-.E..6
3NP53 60-.E..6
3NP54 60-.E..6

B
B
B
B

3NY1 420
3NY1 421
3NY1 422
3NY1 423

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

1.405
1.900
1.980
2.600

Connector and connecting cable


1 m long
3 m long

3NP5 with 3RV1 B


B

3NY1 910
3NY1 911

1
1

1 unit
1 unit

103
103

0.097
0.261

With electronic fuse monitoring for


400 V ... 500 V
(with auxiliary switch 2 NO + 1 NC),
with plug-in connection,
without connector and connecting cable

3NP50 6.-.H.13
3NP52 60-.H.13
3NP53 60-.H.13
3NP54 60-.H.13

B
C
B
C

3NY1 513-0
3NY1 513-2
3NY1 513-3
3NY1 513-4

1
1
1
1

1 unit
1 unit
1 unit
1 unit

103
103
103
103

1.235
2.130
2.146
0.325

Plugs and connecting cables (6-pole)


3 m long

3NP5 with EFM

3NY1 915

1 unit

103

0.372

With actuating cams,


screws and washers
(mounting kit)

3NP501)

3NY3 033

1 unit

103

0.015

With fixing bracket and


screws (mounting kit)

3NP52 ... 3NP54 B

3NY3 034

1 unit

103

0.015

3NP50
3NP52
3NP53, 3NP54

B
B
B

3NY4 031
3NY4 011
3NY4 012

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.218
0.215
0.240

A
A
A

3NY1 102
3NY1 103
3NY1 104

1
1
1

1 unit
1 unit
1 unit

103
103
103

0.071
0.075
0.084

3NY1 074

3NY1 513-3

3NY1 915
Auxiliary switches 1 NO + 1 NC

3NY3 033

3NY3 034
Arc chute
(3 units each are required
for 3NP52, 3NP53 and
3NP54)

3NY4 031

3NY4 011
Molded-plastic masking frames
As replacement for mask- 300 220 mm 3NY1 210
ing frames from assembly 300 245 mm 3NY1 211
kits for installation (without 300 290 mm 3NY1 212
fixing brackets and small
parts)
1)

If retrofitted, drill holes required.

* You can order this quantity or a multiple thereof.

7/114

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Accessories
SITOR fuses for 3NP5 fuse switch disconnectors: Assignment table
For switch disconnectors

SITOR fuses

Type

NH
size

Permissible
load
current1)

Required
conductor
crosssection
Cu

mm 2

Operational
class

Order No.
Rated
current

Rated
voltage2)

DT

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

SITOR 3NE1 fuses for 3NP5


1.5
2.5
4
6
10
10
16
25

000
000
000
000
000
000
000
000

gR/gS
gR/gS
gR/gS
gR/gS
gR/gS
gR/gS
gR/gS
gR/gS

16
20
25
35
40
50
63
80

690
690
690
690
690
690
690
690

}
}
}
}
}
}
}
}

3NE1 813-0
3NE1 814-0
3NE1 815-0
3NE1 803-0
3NE1 802-0
3NE1 817-0
3NE1 818-0
3NE1 820-0

1
1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047
047

0.133
0.124
0.127
0.128
0.126
0.129
0.126
0.124

100
125
125

35
50
50

00
00
00

gR/gS
gRgS
gR

100
125
125

690
690
690

}
}
A

3NE1 021-0
3NE1 022-0
3NE1 022-2

1
1
1

3 units
3 units
3 units

047
047
047

0.204
0.195
0.195

3NP52

160
160
200
200
250
250

70
70
95
95
120
120

1
1
1
1
1
1

gR/gS
gR
gR/gS
gR
gR/gS
gR

160
160
200
200
250
250

690
690
690
690
690
690

}
A
}
A
}
A

3NE1 224-0
3NE1 224-2
3NE1 225-0
3NE1 225-2
3NE1 227-0
3NE1 227-2

1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047

0.522
0.535
0.518
0.508
0.515
0.533

3NP53

315
315
350
350
400

2 70
2 70
2 95
2 95
2 95

2
2
2
2
2

gR/gS
gR
gR/gS
gR
gR/gS

315
315
350
350
400

690
690
690
690
690

A
A
}
A
}

3NE1 230-0
3NE1 230-2
3NE1 331-0
3NE1 331-2
3NE1 332-0

1
1
1
1
1

3 units
3 units
3 units
3 units
3 units

047
047
047
047
047

0.519
0.519
0.687
0.684
0.519

3NP54

450
450
500

2 120
2 120
2 120

2
2
2

gR/gS
gR
gR/gS

450
450
500

690
690
690

A
A
A

3NE1 333-0
3NE1 333-2
3NE1 334-0

1
1
1

3 units
3 units
3 units

047
047
047

0.689
0.691
0.765

560
560
630
625
710
690
685
800
750
720
655
820

2 150
2 150
2 185
2 185
2 (40 x 5)
2 (40 x 5)
2 (40 x 5)
2 (50 x 5)
2 (50 x 5)
2 (50 x 5)
2 (40 x 5)
2 (40 x 8)

3
3
3
3
3
3
3
3
3
3
3
3

gR/gS
gR
gR/gS
gR
gR/gS
gR
gR
gR/gS
gR
gR
gR
gR

560
560
630
630
710
690
710
800
750
800
670
850

690
690
690
690
690
600
600
690
600
600
690
690

A
A
A
A
A
D
B
A
B
A
A
A

3NE1 435-0
3NE1 435-2
3NE1 436-0
3NE1 436-2
3NE1 437-0
3NE1 437-1
3NE1 437-2
3NE1 438-0
3NE1 438-1
3NE1 438-2
3NE1 447-2
3NE1 438-2

1
1
1
1
1
1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047
047
047
047
047
047

1.000
1.098
1.113
1.038
1.045
1.179
1.031
1.560
1.100
1.067
1.044
1.067

3NP50

16
20
25
35
40
50
63
80

SITOR fuses 3NE3 ... 3NE8, 3NC2 up to 3NC8 for 3NP5


3NP50

25
33
45
54
68
89
106
130

4
6
10
16
25
35
50
70

00
00
00
00
00
00
00
00

gR
gR
gR
gR
aR
aR
aR
aR

25
35
50
63
80
100
125
160

690
690
690
690
690
690
690
690

}
}
}
}
}
}
}
}

3NE8 015-1
3NE8 003-1
3NE8 017-1
3NE8 018-1
3NE8 020-1
3NE8 021-1
3NE8 022-1
3NE8 024-1

1
1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047
047

0.193
0.195
0.614
0.196
0.206
0.207
0.195
0.195

3NP523)

32
40
50
63
80
95
120
150

6
10
10
16
25
35
50
70

0
0
0
0
0
0
0
0

gR
gR
gR
gR
aR
aR
aR
aR

32
40
50
63
80
100
125
160

1000
1000
1000
1000
1000
1000
1000
1000

}
}
}
}
}
}
}
}

3NE4 101
3NE4 102
3NE4 117
3NE4 118
3NE4 120
3NE4 121
3NE4 122
3NE4 124

1
1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047
047

0.824
0.258
0.274
0.257
0.261
0.260
0.265
0.274

3NP53

100
120
150
190
230
285
310
330
360

35
50
70
95
120
185
240
240
2 150

1
1
1
1
1
1
1
1
1

aR
aR
aR
aR
aR
aR
aR
aR
aR

100
125
160
200
250
315
350
400
450

1000
1000
1000
1000
1000
1000
1000
1000
1000

A
A
}
}
}
}
A
A
}

3NE3 221
3NE3 222
3NE3 224
3NE3 225
3NE3 227
3NE3 230-0B
3NE3 231
3NE3 232-0B
3NE3 233

1
1
1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047
047
047

0.510
0.506
0.513
0.586
0.580
0.513
0.515
0.520
0.580

210
270
400

120
2
240
2
2 x (30 x 5) 2

aR
aR
aR

250
315
450

800
800
800

}
}
}

3NE4 327-0B
3NE4 330-0B
3NE4 333-0B

1
1
1

3 units
3 units
3 units

047
047
047

0.780
1.539
0.682

1)

In the case of cyclic loads, the currents may have to be reduced again
(precise values on request).

2)

When maintaining overvoltage category 2 (instead of 3) and degree of pollution 2 (instead of 3) to EN 60 947-1, the rated insulation voltage of the
3NP fuse switch disconnector is also Ui = 1000 V.

3)

Due to the mechanical stress on the relatively long fuse blades, SITOR
3NE41 fuses should be switchable only occasionally and only at zero current.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/115

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Accessories
For switch disconnectors

SITOR fuses

Type

Permissible
load
current1)

Required
conductor
crosssection
Cu

NH
size

Operational
class

mm 2

3NP54

360
400
450
510
580
630
630
630

240
2 x 150
2 x 150
2 x 185
2 x 185
2 200
2 200
2 200

2
2
2
2
2
2
2
2

aR
aR
aR
aR
aR
aR
aR
aR

450
600

2 x (30 x 5) 2
2 x (40 x 5) 2

145
180
225
255
330
400

70
95
120
185
240
240

135
180
225
300
425
800

70
95
120
240
2 x 150
3 x (60 x 6)

Order No.

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

3NE3 332-0B
3NE3 333
3NE3 334-0B
3NE3 335
3NE3 336
3NE3 337-8
3NE3 338-8
3NE3 340-8

1
1
1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047
047
047

0.683
0.687
0.697
0.692
0.810
0.687
0.686
0.657

}
}

3NE4 334-0B
3NE4 337

1
1

3 units
3 units

047
047

0.683
0.689

500
500
500
500
500
500

B
B
B
B
B
B

3NC2 423-3C
3NC2 425-3C
3NC2 427-3C
3NC2 428-3C
3NC2 431-3C
3NC2 432-3C

1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047

0.940
0.940
0.940
0.940
0.940
0.940

660
660
660
660
660
600

B
B
B
B
B
C

3NC8 423-3C
3NC8 425-3C
3NC8 427-3C
3NC8 431-3C
3NC8 434-3C
3NC8 444-3C

1
1
1
1
1
1

3 units
3 units
3 units
3 units
3 units
3 units

047
047
047
047
047
047

0.940
0.940
0.940
0.940
0.940
0.940

DT

Rated
current

Rated
voltage2)

400
450
500
560
630
710
800
900

1000
1000
1000
1000
1000
900
800
690

A
A
}
}
}
}
}
}

aR
aR

500
710

800
800

3
3
3
3
3
3

gR
gR
gR
gR
gR
gR

150
200
250
300
350
400

3
3
3
3
3
3

gR
gR
gR
gR
gR
aR

150
200
250
350
500
1000

1)

In the case of cyclic loads, the currents may have to be reduced again
(precise values on request).

2)

When maintaining overvoltage category 2 (instead of 3) and degree of pollution 2 (instead of 3) to EN 60 947-1, the rated insulation voltage of the
3NP fuse switch disconnector is also Ui = 1000 V.

3)

Due to the mechanical stress on the relatively long fuse blades, SITOR
3NE41 fuses should be switchable only occasionally and only at zero current.

Price
per PU

kg

For technical specifications and dimensional drawings of the


SITOR fuses, see chapter 5 "Fuse Systems"

* You can order this quantity or a multiple thereof.

7/116

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NP5 Fuse Switch Disconnectors up to 630 A
Assembly kits for distribution systems

Selection and ordering data


Version

For fuse switch Dimensions


disconnectors

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

mm

For installation in any distribution board


Molded-plastic masking frames
For installation in the cabinet

Height Width

3NP50 with and 215 135


without auxiliary switch
With auxiliary
215 135
switch

3NY1 105

1 1/400 units

103

0.045

3NY1 115

1 1/400 units

103

0.044

For installation in metal front


plates

With and without auxiliary


switch

220 160

3NY1 125

1 unit

103

0.062

For covering the connection


terminals

3NP50 with and 265 135


without auxiliary switch

3NY1 107

1 unit

103

0.073

For covering the cable lug


connections

3NP50 with and 290 135


without auxiliary switch

3NY1 106

1 1/225 units

103

0.071

For separate covering of the


upper and lower cable lug
connections

With auxiliary
switch

290 135

3NY1 116

1 1/225 units

103

0.071

3NP50 with and 290 135


without auxiliary switch

3NY1 108

1 1/200 units

103

0.048

3NY1 107

3NY1 106

Assembly kits for flush mounting


With molded-plastic masking
frame, fixing brackets and
small parts. For disconnectors with and without auxiliary
switches

3NP50 60

250 149

3NY1 208

1 unit

103

0.531

3NP52 60

300 220

3NY1 210

1 unit

103

0.287

3NP53 60

300 245

3NY1 211

1 unit

103

0.298

3NP54 60

300 290

3NY1 212

1 unit

103

0.313

3NY1 212
Covers for cable lug connections

Cover length

Can be screwed onto free


screw end to protect against
accidental touch
(1 set = 6 units)

3NP52

99

3NY1 241

1 unit

103

0.205

3NP53/3NP54

95

3TX6 546-3B

1 unit

101

0.260

120

3NY1 245

1 unit

103

0.336

3NP50

2.5 ... 50 mm2 1) B

3NY1 903

1 unit

103

0.108

3NP52

35 ... 120 mm2

3NY1 907

1 unit

103

0.225

3TX6 546-3B
Conductor
cross-section

Clamp terminals
(1 set = 3 units)

3NY1 907
Busbar width

Busbar adapters
For 60 mm busbar system

3NP50

8US12 91-4SB00

1 unit

143

0.551

3NP52, 3NP53, 250 (length


A
320mm, M10
3NP542)
terminal screws,
connecting cables must be
manufactured)

108

8US12 10-4AG00

1 unit

143

3.060

3NP50

3NY1 940

1 unit

103

0.010

8US12 10-4AG00
Sealing lugs
Retrofittable
(1 pack = 10 units)
1)

Also available in 2-wire version: 1 2.5 mm2 ... 50 mm2 and


1 2.5 ... 35 mm2.

2)

Disconnector is wider than adapter. The adapter can, however, be


expanded to 276 mm with two 8US19 98-2BM00 side modules.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/117

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Introduction

Overview
All key product features at a glance
Compliant with IEC/EN 60439-1, IEC/EN 60947-3
Voltage levels up to 690 V AC
Rated operational current from 160 A to 2000 A
Fuse links according to IEC 60269 Part 1 can be used nickelplated fuse blades are not permissible due to the high transfer
resistance
In open position safe from touch by the back of the hand
(exception 3NJ56: IP00)
Parking position for maintenance
1-pole or 3-pole switchable
Vertical and horizontal mounting position
Climate-proof
Degree of protection IP30 with closed fuse carriers, IP10 with
open fuse carriers (exception 3NJ56: IP00)

7
3NJ4/3NJ5 fuse switch disconnectors

Overview of all components and accessory parts: 3NJ4/3NJ5 in size 00

13

3
12

7
8
9
10

16*BD

11

7/118

Siemens LV 10.1 2011

1 Cover

9 Prism terminal

2 Terminal strip

10 Box terminal

3 Busbar terminal

11 Cover

4 Adapter for screw fixing


on busbar systems

12 3NJ4/5 fuse switch disconnector


Basic device size 00

5 Current transformer

13 Auxiliary switch mounting kit

6 Distance compensation
7 Flat connector
8 Saddle terminal

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Introduction
Overview of all components and accessory parts: 3NJ4/3NJ5 in sizes 1 to 3

4
5
6

16*BE

1 Terminal strip

V terminal

2 Distance
compensation
3 Auxiliary switch

Box terminal

Cover

4 Flat connector
5 Stud terminal

Benefits
Parking position
For maintenance e.g., the fuse carriers of the 1-pole switchable
in-line fuse switch disconnectors of sizes 1 to 3 and the 3-pole
switchable in-line fuse switch disconnectors of size 00 can be
mounted after being turned by 180 (fuse facing outwards).

9 3NJ4/5 fuse switch


disconnector
Basic device size 1/2/3

Application
SENTRON 3NJ41 and 3NJ56 single-pole and 3-pole in-line fuse
switch disconnectors are designed for installation in low-voltage
distribution boards, substations and cable distribution cubicles.

This results in the following advantages:


Visible disconnection point
Depot for fuse links (parking position)
No opportunity for mistakes on replacing the fuse links
Additional touch protection in the vicinity of the lyre-shaped
contacts
Siemens LV 10.1 2011

7/119

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Introduction

Technical specifications
Standards

IEC 60947-1, IEC 60947-3

Type

3NJ41 0
3NJ50

3NJ41 2

3NJ41 3

3NJ41 4

3NJ56

3NJ41 5

3NJ41 8

3NJ41 6

3NJ41 7

Conventional thermal current

Free-air with gG fuses, Ith

160

250

400

630

1250

630

800

1260

1600

Free-air with isolating link, Ith

--

--

--

800

--

1000

1250

1600

2000

Free-air with gTr fuses, Ith

--

--

--

--

1154

722

910

1154

1444

Rated apparent power of the transformer, Sn

kVA

--

--

--

--

800

500

630

800

1000

For fuse links and isolating links

Size

00

4a

2x3

2x3

gG acc. to IEC 60269, In

160

250

400

630

1250

630

800

2 x 630

2 x 800

Free-air with isolating link, In

--

--

--

--

--

1000

1250

2 x 800

2 x 1000

gTr acc. to VDE 0636-2011, Irat

--

--

--

--

1154

722

909

2 x 577

2 x 722

gTr acc. to VDE 0636-2011, Sn

kVA

--

--

--

--

800

500

630

2 x 400

2 x 500

Rated operational voltage Ue


At 40 Hz ...60 Hz AC

690

690

690

690

690

690

400

690

400

Rated insulation voltage Ui

800

1000

1000

1000

1000

1000

690

1000

690

Rated impulse withstand voltage Uimp

kV

12

12

12

12

12

12

Rated conditional short-circuit current with fuses


With gG fuse (rms value)

kA

80/50

110

110

110

80

110

50

80

50

With gTr fuse (rms value)

kA

--

--

--

--

--

--

50

--

--

Max. permissible power loss per


fuse link

12

32

45

48

110

51

61

48

51

Rated short-time withstand current ICW


rms value

kA

--

14.5

14.5

14.5

35

14.5

14.5

25

25

Rated making and breaking capacity


Rated operational current Ie for gG fuses
At AC-21B

400 V AC

160

250

400

630

1250

630

800

2 x 630

2 x 800

AC-22B

400 V AC

160

250

400

630

1250

630

800

2 x 630

2 x 800

AC-23B

400 V AC

--

250

400

--

--

--

--

--

--

AC-21B

500 V AC

160

250

400

630

1250

--

--

--

--

AC-22B

500 V AC

160

250

400

630

1250

--

--

--

--

AC-23B

500 V AC

--

--

--

--

--

--

--

--

--

AC-21B

690 V AC

100

250

400

630

1250

--

--

--

--

AC-22B

690 V AC

100

250

--

--

--

--

--

--

--

AC-23B

690 V AC

--

--

--

--

--

--

--

--

--

--

--

--

--

--

722

910

2 x 577

2 x 722

--

1000

1250

2 x 800

2 x 1000

--

--

--

--

Rated operational current Ie for gTr fuses


At AC-22B

400 V AC

Rated operational current Ie for isolating links


At AC-22B

--

--

--

--

Capacitive switching capacity

400 V AC

kvar

--

105 ...
115

155 ...
185

250 ...300 --

Permissible ambient temperature

-25 ... +55, > 35 C with derating factors

Mechanical endurance, operating cycles

1400

1400

800

800

500

800

500

500

500

Electrical endurance, operating cycles

200

200

200

200

100

100

100

100

100

IP30

IP30

IP30

IP30

IP10

IP30

IP30

IP30

IP30

IP10

IP10

IP10

IP10

IP00

IP10

IP10

IP10

IP10

18

23

54

115

190

275

155

350

375

Degree of protection
With closed fuse carrier,
with terminal cover and peripheral cover
With open fuse carrier
Power loss of the main current paths at Ith

Main conductor connections


M8

M10

M12

M12

M16

2 M12

2 M12

3 M12

4 M12

Flat bars

mm

20

30

30

30

80

80 x 10

80 x 10

--

--

Cable lug, max. conductor cross-section


(stranded)

mm2

95

240

240

240

2 300

2 300

2 300

3 300
4 x 185

4 300
4 x 185

Tightening torque

Nm

12 ... 15

30 ... 35

35 ... 40

35 ... 40

50 ... 60

35 ... 40

35 ... 40

35 ... 40

35 ... 40

Clamp/V terminals

mm2

1.5 ... 70 25 ... 300 25 ... 300 25 ... 300 --

--

--

--

--

M8

M12

M12

M12

M16

M12

M12

M12

M12

16 ... 18

35 ... 40

35 ... 40

35 ... 40

50 ... 60

35 ... 40

35 ... 40

35 ... 40

35 ... 40

Terminal screws

Fixing screws
Required tightening torque for mounting on busbars

7/120

Siemens LV 10.1 2011

Nm

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
1-pole switchable

Selection and ordering data


Rated
For fuse
Center-tooperational links acc. to center
current Ie IEC 60269-1 clearance

NH size

Connection type
DT
(terminal screws/clamptype terminals included in
the scope of supply)1)
optionally top or bottom
(rotatable!)

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.

kg

In-line fuse switch disconnectors, 1-pole switchable


160

00 and 000

185

M8 flat connector

3NJ50 13-0BD00

1 unit

143

2.561

250

185

M10 flat connector

3NJ41 21-3BF01

1 unit

143

5.284

400

2 and 1

185

M12 flat connector

3NJ41 31-3BF01

1 unit

143

5.363

630

3 and 2

185

M12 flat connector

3NJ41 41-3BF01

1 unit

143

6.098

1250

4a

185

M16 60 stud terminal

3NJ56 43-0BB00

1 unit

143

23.608

7
3NJ41 21-3BF01

In-line fuse switch disconnectors, 1-pole switchable,


for integratable current transformers
250

185

M10 flat connector

3NJ41 21-3BF11

1 unit

143

5.690

400

2 and 1

185

M12 flat connector

3NJ41 31-3BF11

1 unit

143

5.720

630

3 and 2

185

M12 flat connector

3NJ41 41-3BF11

1 unit

143

6.680

3NJ41 21-3BF11
1)

Fixing screws for mounting on busbars must be ordered separately.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/121

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
3-pole switchable

Selection and ordering data


Rated
For fuse
Center-tooperational links acc. to center
current Ie IEC 60269-1 clearance

NH size

Connection type
(terminal screws/clamptype terminals included in
the scope of supply)1)
optionally top or bottom
(rotatable!)

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.

kg

In-line fuse switch disconnectors, 3-pole switchable


160

100

M8 flat connector

3NJ41 03-3BF02

1 unit

143

1.400

F70 box terminal

3NJ41 03-3BR02

1 unit

143

1.479

160

00 and 000

185

M8 flat connector

3NJ50 33-0BD00

1 unit

143

2.608

250

185

M10 flat connector

3NJ41 23-3BF01

1 unit

143

5.481

M12 stud terminal

3NJ41 23-3BJ01

1 unit

143

5.512

V terminal

3NJ41 23-3BT01

1 unit

143

5.908

M12 flat connector

3NJ41 33-3BF01

1 unit

143

5.540

M12 stud terminal

3NJ41 33-3BJ01

1 unit

143

5.580

V terminal

3NJ41 33-3BT01

1 unit

143

5.899

M12 flat connector

3NJ41 43-3BF01

1 unit

143

6.426

M12 stud terminal

3NJ41 43-3BJ01

1 unit

143

6.321

V terminal

3NJ41 43-3BT01

1 unit

143

6.675

400

00 and 000

2 and 1

185

3NJ41 23-3BF01
630

3 and 2

185

In-line fuse switch disconnectors, 3-pole switchable,


with electronic fuse monitoring (EFM)
160

00 and 000

100

M8 flat connector

3NJ41 03-3CF02

1 unit

143

1.400

250

185

M10 flat connector

3NJ41 23-3CF01

1 unit

143

1.400

400

2 and 1

185

M12 flat connector

3NJ41 33-3CF01

1 unit

143

1.400

630

3 and 2

185

M12 flat connector

3NJ41 43-3CF01

1 unit

143

1.400

3NJ41 .3-3CF..

In-line fuse switch disconnectors, 3-pole switchable,


for integratable current transformers
160

00 and 000

100

M8 flat connector

3NJ41 03-3BF12

1 unit

143

1.140

250

185

M10 flat connector

3NJ41 23-3BF11

1 unit

143

5.890

400

2 and 1

185

M12 flat connector

3NJ41 33-3BF11

1 unit

143

5.910

630

3 and 2

185

M12 flat connector

3NJ41 43-3BF11

1 unit

143

6.870

In-line fuse switch disconnectors, 3-pole switchable, for integratable


current transformers, with electronic fuse monitoring (EFM)
160

00 and 000

100

M8 flat connector

3NJ41 03-3CF12

1 unit

143

1.400

250

185

M10 flat connector

3NJ41 23-3CF11

1 unit

143

1.400

400

2 and 1

185

M12 flat connector

3NJ41 33-3CF11

1 unit

143

1.400

630

3 and 2

185

M12 flat connector

3NJ41 43-3CF11

1 unit

143

1.400

PS*/
P. unit

PG

Weight
per PU
approx.

Transformer
apparent
power

Rated
apparent
power of
the gTr
fuses

Center-tocenter
clearance

Rated current Rated operaDT


tional current Ie
of gTr fuses
with 3NJ49148BA00 isolating
link

kVA

kVA

mm

Order No.

Price
PU
per PU (UNIT,
SET,
M)

kg

In-line fuse switch disconnectors, 3-pole switchable,


for secondary-side fusing of transformers and feeder lines
500

500

185

722

1000

3NJ41 53-3BF01

1 unit

143

11.030

630

630

185

909

1250

3NJ41 83-3BF01

1 unit

143

12.943

800

2 x 400

185

2 x 577

1600

3NJ41 63-3BF01

1 unit

143

12.943

1000

2 x 500

185

2 x 722

2000

3NJ41 73-3BF01

1 unit

143

12.943

3NJ41 63-3BF01
1)

Fixing screws for mounting on busbars must be ordered separately.

* You can order this quantity or a multiple thereof.

7/122

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Accessories

Selection and ordering data


Version

For in-line
fuse switch
disconnectors
or dimensions

DT

Order No.

Cover
Size 00
Additional touch protection with
use of cable lugs

3NJ50 33,
3NJ5013

Cover1)
Size 1 to 3
Additional touch protection
with use of cable lugs or connection
from above

3NJ41 2 to
3NJ41 4,
3NJ41 5,
3NJ41 8

Covers size 3
For double bars

3NJ41 4

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

3NJ49 12-1FA02

1 unit

143

0.090

3NJ49 12-1AA01

1 unit

143

0.103

3NJ49 12-1EA00

1 unit

143

0.200

3NJ49 12-1DA02

1 unit

143

0.005

50 mm wide

3NJ49 12-2AA00

1 unit

143

0.189

According to the size of the switch


disconnectors: sizes 1 to 3
(for fitting in the cutout of the control
panels)

100 mm wide

3NJ49 12-2BA00

1 unit

143

0.215

For 3NJ41 03

50 mm wide

3NJ49 12-2CA00

1 unit

143

0.090

Fixing clips
(1 set = 4 units, including
fixing accessories)
2 units per side, for fixing the cover of
the control panel front

3NJ41

3NJ49 18-0AA00

1 unit

143

0.130

kg

33NJ49 12-1AA01

3NJ49 12-1EA00
Cover size 00
3NJ41 03
(can also be used as spacer)
top and bottom
to cover long cable lugs and compensate for combination of 3NJ41 03 with
terminals 3NJ41 2 to 3NJ41 4
(1 set = 2 units: short and long 2) )

3NJ49 12-1DA02
Blanking covers
For panel cut-out

3NJ49 12-2AA01

3NJ49 12-2BA00

3NJ49 12-2CA01

3NJ49 18-0AAA00
1)

With cable lugs and connection from above, the terminal cover can be
extended by connecting two units together.

2)

Can be shortened (in exchange for short cover, included in the scope of
supply of the in-line disconnector).

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/123

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Accessories
Version

For in-line
fuse switch
disconnectors
or dimensions

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

Unequipped section cover for busbars


To be fitted directly in the drilled holes of the busbars

$ Busbar center-to-center spacing 185 mm 50 mm wide

3NJ49 12-3AA00

1 unit

143

0.148

% Busbar center-to-center spacing 185 mm 100 mm wide

3NJ49 12-3BA01

1 unit

143

0.372

& Busbar center-to-center spacing 100 mm 50 mm wide


(Also for covering a blank space on
3NJ49 18-0DA02 or 3NJ59 30-3BB)

3NJ49 12-3CA00

1 unit

143

0.105

For fitting of two 3NJ41 03 fuse switch


3NJ41 03
disconnectors (= 1 holder) onto a busbar
system with 185 mm center-to-center
spacing (including adaptation of the
installation depth to that of the 3NJ41 2 to
3NJ41 4 fuse switch disconnectors)

3NJ49 18-0DA02

1 unit

143

0.751

For fitting two 3NJ50 fuse switch disconnectors (= 1 holder) (to adapt the overall
depth of sizes 1 to 3)

3NJ59 30-3BB

1 unit

143

0.675

For fitting one 3NJ41 03 fuse switch dis3NJ41 03


connector (= 3 separate brackets) onto a
busbar system with 60 mm center-to-center spacing

3NJ49 18-0EA00

1 unit

143

0.232

Adapters with busbar terminals


3NJ41 03
For fitting two 3NJ41 03 fuse switch
disconnectors (= 1 holder) onto a busbar
system with 185 mm center-to-center
spacing (including adaptation of the overall
depth to the 3NJ41 2 to 3NJ41 4 fuse switch
disconnectors)

3NJ49 18-0DB02

1 unit

143

0.751

Fixing screws
for fitting 3NJ41 03 switch disconnectors
with integratable current transformers onto
adapters
(1 set = 3 items)

3NJ41 03

3NJ49 18-0DC02

1 unit

143

0.200

Busbar supports
For 100 mm and 185 mm center-to-center
spacing, for screwing on of busbars

3NJ41 and 3NJ5

3NJ59 74-0AB

1 unit

143

0.463

Grounding kit with


connecting cable 25 mm2

3NJ41 4 to
3NJ41 8

3NJ49 10-1AA00

1 unit

143

4.200

Busbar terminals

3NJ41 03

3NJ49 11-3AA00

1 unit

143

0.176

For rapid mounting of the in-line


disconnectors onto the busbars
(1 set = 3 units)

3NJ41 2 to
3NJ41 4

3NJ49 11-3BA01

1 unit

143

0.607


Adapters for screw fixing on busbar systems

3NJ49 18-0DA02

3NJ49 18-0EA00

3NJ50 13 and
3NJ50 33

3NJ59 74-0AB

3NJ49 10-1AA00

3NJ49 11-3AA00

3NJ49 11-3BA01

* You can order this quantity or a multiple thereof.

7/124

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Accessories
Version

For fuse switch


disconnectors

DT

Order No.

Saddle terminals
Connector Cu, 1.5 ... 70 mm2
(1 set = 3 units)

3NJ41 03

Prism terminal kit


Connector Al/Cu, 10 ... 70 mm2
(1 set = 3 units)

3NJ41 03

Box terminal kit


Connector Al/Cu, 95 ... 240 mm2
(for connection to flat connector)
(1 set= 3 units)

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

3NJ49 11-4AA00

1 unit

143

0.041

3NJ49 11-1AA00

1 unit

143

0.098

3NJ41 2 to 3NJ41 4 A

3NJ49 11-2BQ00

1 unit

143

0.949

kg

3NJ49 11-4AA00

3NJ49 11-1AA00

3NJ4911-2BQ00
Busbar connection assembly kit for NH 1, 2, 3
With flat connector
2 x 240 mm2

3NJ41 2 to 3NJ41 4 A

3NJ49 11-5AA00

1 unit

143

0.500

2 x 300 mm2/3 x 120 mm2

3NJ41 2 to 3NJ41 4 A

3NJ49 11-5BA00

1 unit

143

1.700

1 x 400 mm2

3NJ41 2 to 3NJ41 4 A

3NJ49 11-5CA00

1 unit

143

1.800

3NJ49 11-5AA00

3NJ49 11-5BA00

3NJ49 11-5CA00
Busbar connection assembly kit for NH3
as double bars
3 x 300 mm2 / 4 x 185 mm2

3NJ41 4

3NJ49 11-6AA00

1 unit

143

2.800

4 x 240 mm2

3NJ41 4

3NJ49 11-6BA00

1 unit

143

3.800

3NJ49 11-6AA00

3NJ49 11-6BA00

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/125

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Accessories
Version

For fuse switch


disconnectors

DT

Order No.

Mechanical coupling of operating


handles

3NJ41 4

Auxiliary switch mounting kit

3NJ41 to 3NJ50

3NJ41 8

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.

3NJ49 11-6CA00

1 unit

143

0.150

3NJ49 13-1AA01

1 unit

143

0.029

3NJ49 14-8AA00

1 unit

143

1.341

3NJ49 14-8BA00

1 unit

143

2.800

3NJ49 18-1AA00

1 unit

143

0.120

kg

3NJ49 11-6BA00
For sizes 00 to 3 with connecting
cables, for 3-pole switchable switch
disconnectors only

3NJ49 13-6AA02
Fuse 630 kVA 909 A
Size NH 3
Specially for the protection of
transformers
(minimum order quantity 3 units)

Isolating links
Size NH 3, 1250 A

3NJ49 14-8BA00
Mounting hooks
(one per in-line disconnector required)

3NJ49 18-1AA00
Distance compensation

3NJ41 03

3NJ49 15-1BA00

1 unit

143

0.020

For fuse switch disconnectors, with


integratable current transformers if no
current transformer is built in.

3NJ41 2 to 3NJ41 4 }

3NJ49 15-2BA00

1 unit

143

0.095

Terminal strips

3NJ41 03

3NJ49 15-1CA00

1 unit

143

0.030

3NJ41 2 to 3NJ41 4 }

3NJ49 15-2CA00

1 unit

143

0.110

3NJ49 15-1BA00

3NJ49 15-2BA00

3NJ49 15-1CA00

3NJ49 15-2CA00

* You can order this quantity or a multiple thereof.

7/126

Siemens LV 10.1 2011

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Accessories
Version

For fuse switch


disconnectors

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

Current transformers .../1 A

3NJ49 15-1FB20

3NJ49 15-2HA20

100/1 A, Cl. 0.5, 1.5 VA


100/1 A, Cl. 1, 2.0 VA
150/1 A, Cl. 0.5, 2.5 VA
150/1 A, Cl. 0.5 calibrated, 2.5 VA
150/1 A, Cl. 1, 3.0 VA
75/1 A, Cl. 1, 1.5 VA
100/1 A, Cl. 0.5, 1.5 VA
100/1 A, Cl. 1, 2.0 VA
150/1 A, Cl. 0.5, 2.5 VA
150/1 A, Cl. 1, 2.5 VA
250/1 A, Cl. 0.5, 2.5 VA
250/1 A, Cl. 0.5 calibrated, 2.5 VA
250/1 A, Cl. 1, 5.0 VA
400/1 A, Cl. 0.5, 2.5 VA
400/1 A, Cl. 0.5 calibrated, 2.5 VA
400/1 A, Cl. 1, 5.0 VA
500/1 A, Cl. 0.5, 2.5 VA
500/1 A, Cl. 1, 5.0 VA
600/1 A, Cl. 0.5, 2.5 VA
600/1 A, Cl. 0.5 calibrated, 2.5 VA
600/1 A, Cl. 1, 5.0 VA

3NJ41 03
3NJ41 03
3NJ41 03
3NJ41 03
3NJ41 03
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4

C
C
C
D
}
C
C
C
C
C
C
D
}
C
D
}
C
C
C
D
}

3NJ49 15-1EA10
3NJ49 15-1EA20
3NJ49 15-1FA10
3NJ49 15-1FA11
3NJ49 15-1FA20
3NJ49 15-2DA20
3NJ49 15-2EA10
3NJ49 15-2EA20
3NJ49 15-2FA10
3NJ49 15-2FA20
3NJ49 15-2GA10
3NJ49 15-2GA11
3NJ49 15-2GA20
3NJ49 15-2HA10
3NJ49 15-2HA11
3NJ49 15-2HA20
3NJ49 15-2JA10
3NJ49 15-2JA20
3NJ49 15-2KA10
3NJ49 15-2KA11
3NJ49 15-2KA20

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143

0.250
0.250
0.250
0.250
0.250
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190

3NJ41 03
3NJ41 03
3NJ41 03
3NJ41 03
3NJ41 03
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4
3NJ41 2 to 3NJ41 4

C
C
C
D
}
D
D
D
C
C
C
D
}
C
D
}
D
D
D
D
}

3NJ49 15-1EB10
3NJ49 15-1EB20
3NJ49 15-1FB10
3NJ49 15-1FB11
3NJ49 15-1FB20
3NJ49 15-2DB20
3NJ49 15-2EB10
3NJ49 15-2EB20
3NJ49 15-2FB10
3NJ49 15-2FB20
3NJ49 15-2GB10
3NJ49 15-2GB11
3NJ49 15-2GB20
3NJ49 15-2HB10
3NJ49 15-2HB11
3NJ49 15-2HB20
3NJ49 15-2JB10
3NJ49 15-2JB20
3NJ49 15-2KB10
3NJ49 15-2KB11
3NJ49 15-2KB20

1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit

143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143
143

0.250
0.250
0.250
0.250
0.250
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190
0.190

Current transformers .../5 A

3NJ49 15-1FB20

100/5 A, Cl. 0.5, 1.0 VA


100/5 A, Cl. 1, 1.5 VA
150/5 A, Cl. 0.5, 1.5 VA
150/5 A, Cl. 0.5 calibrated, 1.5 VA
150/5 A, Cl. 1, 2.5 VA
75/5 A, Cl. 1, 1.5 VA
100/5 A, Cl. 0.5, 1.0 VA
100/5 A, Cl. 1, 2.0 VA
150/5 A, Cl. 0.5, 1.5 VA
150/5 A, Cl. 1, 2.5 VA
250/5 A, Cl. 0.5, 2.5 VA
250/5 A, Cl. 0.5 calibrated, 2.5 VA
250/5 A, Cl. 1, 3.75 VA
400/5 A, Cl. 0.5, 2.5 VA
400/5 A, Cl. 0.5 calibrated, 2.5 VA
400/5 A, Cl. 1, 5.0 VA
500/5 A, Cl. 0.5, 2.5 VA
500/5 A, Cl. 1, 5.0 VA
600/5 A, Cl. 0.5, 2.5 VA
600/5 A, Cl. 0.5 calibrated, 2.5 VA
600/5 A, Cl. 1, 5.0 VA

3NJ49 15-2HB20

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

7/127

Siemens AG 2011

Switch Disconnectors
SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Notes

7/128

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
8/2

Introduction

8/5

Control Switches

8/8

Pushbuttons

8/12

Light Indicators

8/15

ON/OFF Switches

8/20

DC Isolators

8/22

Busbar Systems

8/24

Remote Control Switches

8/28

Switching Relays

8/30
8/33

Insta Contactors
Insta contactors, DC technology
Insta contactors, AC technology

8/37

Soft-Starting Devices

8/38
8/45
8/49
8/51

Timers
Digital time switches
Mechanical time switches
Timers for buildings
Timers for industrial applications
Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Introduction

Field of application

Industry

Devices

Standards

Used in

Control switches

8/5

For the switching of lighting and other


electrical devices up to 20 A.

IEC/EN 60947-3;

IEC/EN 60669-1;
GB14048.3-2002
CCC
For use in control cabinets for the logical
linking of functions.

Pushbuttons

8/8

To be used as pushbuttons in control


IEC/EN 60947-3;

systems, e.g. to switch on seal-in circuits IEC/EN 60669-1;


or as pushbuttons with maintained-con- GB14048.3-2002 CCC
tact function for manual use, as control
switches or for the switching of loads up
to 20 A.

--

Light indicators

8/12

Light indicators for signaling switching


states or faults in systems.

DIN VDE 0710-1

--

ON/OFF switches

8/15

For the switching of lighting, motors and 16 A ... 25 A and


other electrical devices from 20 to 125 A. 40 A ... 100 A:
IEC/EN 60947-3;
IEC/EN 60669-1,
(VDE 0632-1)

Non-residential
buildings

Page

Residential
buildings

Overview

32 A and 125 A:
IEC/EN 60947-3;
GB14048.3-2002 CCC

8/2

DC isolators

8/20

The DC isolator is a specific switch disconnector for activating the solar modules in photovoltaic systems according
to DIN VDE 0100-712.

IEC/EN 60947-3,
IEC/EN 60669-1

Busbar Systems

8/22

For fast and safe connection

IEC/EN 60439-1

--

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices

Page Field of application

Standards

Non-residential

Residential
buildings

Industry

Introduction
Devices

Used in

Remote control switches

8/24

For the switching of lighting up to


16 A in rooms using several pushbuttons and central ON/OFF
switches.

IEC 60669-1
IEC 60669-2
IEC 60669-3
EN 60669
EN 60669-2-2 and
EN 60669-2-2/A1

Switching relays

8/28

For the switching of small loads up


to 16 A or as coupling devices in
control systems.

EN 60947-5-1

--

8
Insta contactors
Insta contactors, DC technology

8/30

Insta contactors 24, 40 and 63 A for


the switching of heating, lighting,
such as fluorescent lamps, incandescent lamps, ohmic or inductive
loads.

IEC 60947-4-1
IEC 60947-5-1
IEC 61095
EN 60947-4-1
EN 60947-5-1
EN 61095
UL 508

Insta contactors, AC technology

8/33

Insta contactors 20, 25, 40 and 63 A


for the switching of heating, lighting,
such as fluorescent lamps, incandescent lamps, ohmic or inductive
loads.

IEC 60947-4-1

IEC 60947-5-1, IEC 61095,


EN 60947-4-1
EN 60947-5-1
EN 61095
NF C 61-480
(NF EN 61095)

Soft-starting devices

8/37

Protection of machines with transEN 60947-4-2


mission, belt or chain drives, conveyor belts, fans, pumps,
compressors, packing machines or
door operating mechanisms

--

--

Siemens LV 10.1 2011

8/3

Siemens AG 2011

Switching Devices

Page

Field of application

Standards

Used in

Residential
buildings

Industry

Devices

Non-residential
buildings

Introduction

8/38

Minute-precise switching of devices and system components in day, week and year programs. Unique due to the wide variety of
functions offered by the Mini and Top versions;
for PC programming Astro, Profi and Expert

IEC 60730-1 and


IEC 60730-2-7

Accurate and 15-minute switching accuracy.


With automatic time setting during commissioning and automatic switching to daylight
savings.

IEC 60730-1 and


IEC 60730-2-7

Timers
Digital time switches

Mechanical time switches

8/45

EN 60730-1 and
EN 60730-2-7

EN 60730-1 and
EN 60730-2-7
UL 60730

8/4

Timers for buildings

8/49

Lighting controls with stairwell lighting timers


IEC 60699
ensure the safe use of stairwells and save
EN 60669,
energy. Expanded applications for common
DIN 18015
rooms and garages, as well as the time switching of ventilators and fluorescent lamps.

Timers for industrial


applications

8/51

Multifunctional, delay, wiper, flashing and OFF- IEC 60255


delay timers in control circuits expand the use EN 60255
of distribution boards in both small and large
plants.

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Control switches

Overview
Two-way switches are used in control cabinets and distribution
boards for switching small loads on/off or over.

Control switches in a range of contact versions have an integral


control lamp for the ON setting.

Group switches with center position permit the positions


open/stop/closed, for example to control anti-clockwise rotation
- Off - clockwise rotation.

The auxiliary switch (AS) signals the contact position of the


switch. It has the same design as the auxiliary switch used for
the miniature circuit breakers (see Chapter "Miniature Circuit
Breakers").

Benefits

8
The control switches can be bus-mounted with each other or
with 5TE4 8 pushbuttons, 5TE5 8 light indicators or 5TT4 1 remote control switches and 5TT4 2 switching relays. This saves
time and space.
For busbars, see page 8/22.

The handle locking device prevents undesired manual on and


off switching. This increases operational safety.
The handle locking device is a universal accessory for all
switches and miniature circuit breakers. This simplifies
logistics.

Technical specifications
5TE8 1
IEC/EN 60947-3;
IEC/EN 60669-1
EN 60669

Standards
Approvals
Rated operational current Ie

Per conducting path

Rated operational voltage Ue

1-pole
Multipole

V AC
V AC

Rated power dissipation Pv

Contact per pole

Conventional thermal current Ithe (enclosed)

VA

20
230
400
0.7

20

Rated breaking capacity

At p.f. = 0.65

60

Rated making capacity

At p.f. = 0.65

60

Short-circuit strength
In conjunction with fuse of the same
rated operational current

EN 60269 gL/gG

kA

10

kV

>5

Open contacts
Between the poles

mm
mm

2>2
>7

mm

>7

Rated impulse withstand voltage Uimp


Clearances
Creepage distances
Mechanical service life

Switching cycles

Electrical service life

Switching cycles

Minimum contact load


Rated short-time currents
Per conducting path at p.f. = 0.7
(The respective rated surge current can
be calculated by multiplying by a factor of 1.5).

Up to 0.2 s
Up to 0.5 s
Up to 1 s
Up to 3 s

Terminals
Max. tightening torque

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Permissible ambient temperature


Resistance to climate
At 95 % relative humidity

Acc. to DIN 50015

25000
10000
V; mA

10; 300

A
A
A
A

650
400
290
170

Nm

1
1.2

mm2
mm2

1.5 ... 6
1 ... 6

-5 ... +40

45

Siemens LV 10.1 2011

8/5

Siemens AG 2011

Switching Devices
Control switches

Selection and ordering data


Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Two-way switches (20 A)


With sealable switch position,
separate handle locking device can be retrofitted
Mountable auxiliary switch
1 NO + 1 NC

20

400

5TE8 151

1 unit

027

0.075

Auxiliary switch cannot be retrofitted


2 NO + 2 NC

20

400

5TE8 152

1 unit

027

0.095

3 NO + 1 NC

20

400

5TE8 153

1 unit

027

0.094

1 CO

20

230

5TE8 161

1 unit

027

0.072

2 CO

20

400

5TE8 162

1 unit

027

0.090

8
Group switches with center position (20 A)
With sealable switch position,
separate handle locking device can be retrofitted
Auxiliary switch cannot be retrofitted
1 CO

20

230

5TE8 141

1 unit

027

0.060

2 CO

20

400

5TE8 142

1 unit

027

0.091

Control switch (20 A)


With fixed mounted glow lamp 230 V or diode 48 V,
with replaceable, white transparent luminescent cap,
with sealable switch position, separate handle locking
device can be retrofitted
Auxiliary switch cannot be retrofitted
6
6

1
1

}
B

5TE8 101
5TE8 101-3

1
1

1 unit
1 unit

027
027

0.070
0.056

1 NO, for max. 150 m cable length


20
230
6

5TE8 105

1 unit

027

0.066

2 NO

20

400

5TE8 102

1 unit

027

0.078

3 NO

20

400

5TE8 103

1 unit

027

0.091

1.5

5TE8 108

1 unit

027

0.137

1 NO

20
20

230
48

With mounted auxiliary switch (1 NO, 1 NC)


3 NO
20
400
6

* You can order this quantity or a multiple thereof.

8/6

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Control switches
Version

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW
Auxiliary switches (AS)
For right-side retrofitting with factory-fitted brackets,
for further technical specifications, see also Section
"Miniature circuit breakers"
1 NO + 1 NC

0.5

5ST3 010

1 unit

027

0.066

2 NO

0.5

5ST3 011

1 unit

027

0.055

2 NC

0.5

5ST3 012

1 unit

027

0.055

5ST3 801

1 unit

027

0.012

Handle locking devices


For all 5TE8 switches,
can be sealed against unwanted manual ON/OFF
switching,
for padlock with max. 3 mm shackle

Spacers
Contour for modular devices with a mounting depth
of 70 mm;
can be snapped onto either side of the busbar, so
that two spacers allow for convenient cable routing
0.5

5TG8 240

1 2 units

027

0.010

5TG8 068

027

0.006

Cap sets
For manual changing of the luminous plates for
5TE8 10 control switches
Cap set comprising 1 red, green, yellow, white and
blue plate each

1 set

For busbars for control switch, see page 8/22.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/7

Siemens AG 2011

Switching Devices
Pushbuttons

Overview
The pushbuttons are used in control systems, e.g. to switch on
seal-in circuits or as pushbuttons with maintained-contact

function for manual use, as control switches or for the switching


of loads up to 20 A.

Benefits

Pushbuttons with setting function for momentary-contact or


maintained-contact operation can be changed over after
installation and connection. This increases the application
options of the devices and saves laborious working in the
distribution board.

Pushbuttons and light indicators with separate infeed in one


device. This means they can also be used for voltages other
than the switching voltage.
Control pushbuttons with remote signaling pilot light in one
modular width in momentary-contact or maintained-contact
operation save space.

In the case of devices with two pushbuttons and two lamps,


each pushbutton must be set separately. This increases the
application options of devices.

Pilot lights and caps can also be safely replaced during operation without the use of tools. Functionality is quickly restored.
A range of different-colored, transparent caps enable the
signaling of plant states in compliance with IEC 60073. Three
indications are possible for each device - this saves space.

The lamps are mounted in a slotted base, which protects


against polarity reversal. Thus, correct polarization is always
ensured for DC applications.

8/8

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Pushbuttons

Technical specifications
5TE4 8
IEC/EN 60947-3;
IEC/EN 60669-1
EN 60669-1

Standards
Approvals
Rated operational current Ie

Per conducting path

20

Rated operational voltage Ue

1-pole
Multipole

V AC
V AC

230
400

Rated power dissipation Pv

Per pole

VA

0.6

20

Conventional thermal current Ithe (enclosed)


Rated breaking capacity

At p.f. = 0.65

60

Rated making capacity

At p.f. = 0.65

60

kV

>5

mm
mm

2>2
>7

mm

>7

Rated impulse withstand voltage Uimp


Open contacts
Between the poles

Clearances
Creepage distances

Switching cycles

Mechanical service life


Minimum contact load
Rated short-time currents
Per conducting path at p.f. = 0.7

Up to 0.2 s
Up to 0.5 s
Up to 1 s
Up to 3 s

(The respective rated surge current can


be calculated by multiplying by a factor of 1.5).
Terminals
Max. tightening torque

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Permissible ambient temperature


Resistance to climate
At 95 % relative humidity

Acc. to DIN 50015

Power loss of 5TG8 05.-. LEDs

5TG8 05.-.

Rated power dissipation Pv


LED

VA

25000
V; mA

10; 300

A
A
A
A

650
400
290
170

Nm

1
1.2

mm2
mm2

1.5 ... 6
1 ... 6

-5 ... +40

45

0.4

Color coding according to IEC 60073


Color

Safety of people or environment

Process state

System state

Red

Danger

Emergency

Faulty

Yellow

Warning/Caution

Abnormal

Green

Safety

Normal

Blue

Stipulation

White
Gray
Black

No special significance assigned

Siemens LV 10.1 2011

8/9

Siemens AG 2011

Switching Devices
Pushbuttons

Selection and ordering data


Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Pushbuttons without maintained-contact function


1 NO + 1 NC
1 gray pushbutton

20

400

5TE4 800

1 unit

027

0.073

1 NO, 1 NO
1 green pushbutton, 20
1 blue pushbutton

400

5TE4 804

1 unit

027

0.093

20

400

5TE4 805

1 unit

027

0.074

1 NO + 1 NC
1 green pushbutton 20

400

5TE4 806

1 unit

027

0.067

1 NO + 1 NC
1 yellow pushbutton 20

400

5TE4 807

1 unit

027

0.074

1 NO + 1 NC
1 blue pushbutton

400

5TE4 808

1 unit

027

0.071

1 NO + 1 NC
1 red pushbutton

20

Pushbuttons with maintained-contact function


1 NO + 1 NC
1 gray pushbutton

20

400

5TE4 810

1 unit

027

0.074

2 NO
1 gray pushbutton

20

400

5TE4 811

1 unit

027

0.074

3 NO + N
1 gray pushbutton

20

400

5TE4 812

1 unit

027

0.093

4 NC
1 gray pushbutton

20

400

5TE4 813

1 unit

027

0.092

2 CO
1 gray pushbutton

20

400

5TE4 814

1 unit

027

0.089

Control pushbuttons with maintained-contact function


and/or momentary-contact function and lamp, 230 V
For max. 5 m cable length
1 NO + 1 NC
1 red pushbutton

20

400

5TE4 820

1 unit

027

0.083

1 NO
1 red pushbutton

20

230

5TE4 821

1 unit

027

0.073

2 NO
1 red pushbutton

20

400

5TE4 823

1 unit

027

0.084

2 NC
1 red pushbutton

20

400

5TE4 824

1 unit

027

0.083

5TE4 822

1 unit

027

0.074

Control pushbuttons with maintained-contact function


and/or momentary-contact function and lamp, 230 V
For max. 150 m cable length
1 NO
1 red pushbutton

20

230

Double pushbuttons with maintained-contact function and/or


momentary-contact function
1 NO and 1 NC,
1 green pushbutton, 20
1 red pushbutton

400

5TE4 830

1 unit

027

0.078

1 NO, 1 NC and 1NO, 1 NC


1 green pushbutton, 20
1 red pushbutton

400

5TE4 831

1 unit

027

0.095

* You can order this quantity or a multiple thereof.

8/10

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Pushbuttons
Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Double pushbutton with maintained-contact function


and/or momentary-contact function and two lamps, 230 V
For max. 5 m cable length
1 NO and 1 NO,
20
1 green pushbutton,
1 red pushbutton

400

5TE4 840

1 unit

027

0.094

1 NO and 1 NC,
20
1 green pushbutton,
1 red pushbutton

400

5TE4 841

1 unit

027

0.094

PG

Weight
per PU
approx.

Version

Ie

Un

mA

LEDs for manual replacement


White
Red
Yellow

0.4

DT

12 ... 60 AC/DC

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

kg

C
C
C

5TG8 056-0
5TG8 056-1
5TG8 056-2

1
1
1

5 units
5 units
5 units

027
027
027

0.005
0.005
0.005

C
C

5TG8 056-3
5TG8 056-4

1
1

5 units
5 units

027
027

0.005
0.005

C
C
C

5TG8 057-0
5TG8 057-1
5TG8 057-2

1
1
1

5 units
5 units
5 units

027
027
027

0.005
0.005
0.005

C
C

5TG8 057-3
5TG8 057-4

1
1

5 units
5 units

027
027

0.005
0.005

C
C
C

5TG8 058-0
5TG8 058-1
5TG8 058-2

1
1
1

5 units
5 units
5 units

027
027
027

0.005
0.005
0.005

C
C

5TG8 058-3
5TG8 058-4

1
1

5 units
5 units

027
027

0.005
0.005

Gray, non-transparent (1 set = 5 units)

5TG8 060

1 set

027

0.001

Red, transparent (1 set = 5 units)

5TG8 061

1 set

027

0.004

Green, transparent (1 set = 5 units)

5TG8 062

1 set

027

0.001

Yellow, transparent (1 set = 5 units)

5TG8 063

1 set

027

0.004

Blue, transparent (1 set = 5 units)

5TG8 064

1 set

027

0.003

Black, non-transparent (1 set = 5 units)

5TG8 065

1 set

027

0.001

White, transparent (1 set = 5 units)

5TG8 066

1 set

027

0.003

Red and green (1 set contains 10 lamps per color),


yellow, blue and white (1 set contains 5 lamps per color)

5TG8 067

1 set

027

0.011

Red, green, yellow (1 set = 3 units)

5TG8 070

1 set

027

0.007

Green
Blue
White
Red
Yellow

0.4

115 AC/DC

Green
Blue
White
Red
Yellow

0.4

230 AC

Green
Blue
Cap sets, manually replaceable with colored caps with
or without lamps

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/11

Siemens AG 2011

Switching Devices
Light indicators

Overview
Light indicators are used to signal switching states or faults in
systems.

They are available as single, double or triple light indicators.


The triple light indicators are used as phase or signal indicators.

Benefits

Pilot lights and caps can also be safely replaced during operation without the use of tools. Functionality is quickly restored.
A range of different-colored, transparent caps enable the
signaling of plant states in compliance with IEC 60073. Three
indications are possible for each device - this saves space.

The lamps are mounted in a slotted base, which protects


against polarity reversal. This ensures the correct polarization
for all DC applications.
A range of different-colored, transparent caps enable the
signaling of plant states in compliance with IEC 60073. Three
indications are possible for each device - this saves space.

The devices have preferred positions for the N terminals, so


that it is possible to bus-mount several devices. This ensures
fast and simple installation
The options for bus mounting are described in the chapter
"Miniature circuit breakers".

A light indicator with three lamps enables three-phase signaling and "traffic-light signaling" in a single modular width. This
saves valuable installation space and makes things more
manageable. This enables implementation of the signaling of
system states as defined in IEC 60073.

8/12

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Light indicators

Technical specifications
5TE5 8
DIN VDE 0710-1

Standards
Rated operational voltage Ue

Max.

Rated power dissipation Pv


Clearances

Between the terminals

Terminals
Max. tightening torque

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Permissible ambient temperature


Resistance to climate
At 95 % relative humidity

Acc. to DIN 50015

V AC

230 (for different voltages see 5TG8 lamps)

VA

See 5TG8 lamps

mm

>7

Nm

1
1.2

mm2
mm2

1.5 ... 6
1 ... 6

-5 ... +40

45

Color coding according to IEC 60073

5TG8 05.
Rated power dissipation Pv
LED

VA

Meaning

0.4

Safety of people
and environment

Process state

System state

Color
Red

Danger

Emergency

Faulty

Yellow

Warning/Caution

Abnormal

Green

Safety

Normal

Blue

Stipulation

White

No special significance assigned

Selection and ordering data


Version

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Light indicators for a max. cable length of up to 5 m


With 1 red lamp
230
6
With 2 lamps, green and red
With 3 green lamps
With 3 lamps, red, yellow and green

}
}
}
}

5TE5 800
5TE5 801
5TE5 802
5TE5 803

1 1/12 units
1
1 unit
1
1 unit
1
1 unit

027
027
027
027

0.051
0.068
0.076
0.076

5TE5 804

027

0.063

Light indicators for a max. cable length of up to 250 m


With 1 red lamp

230

1 unit

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/13

Siemens AG 2011

Switching Devices
Light indicators
Ie

Ue

mA

0.4

12 ... 60 AC/DC

LEDs for manual replacement


White
Red
Yellow

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

C
C
C

5TG8 056-0
5TG8 056-1
5TG8 056-2

1
1
1

5 units
5 units
5 units

027
027
027

0.005
0.005
0.005

C
C

5TG8 056-3
5TG8 056-4

1
1

5 units
5 units

027
027

0.005
0.005

C
C
C

5TG8 057-0
5TG8 057-1
5TG8 057-2

1
1
1

5 units
5 units
5 units

027
027
027

0.005
0.005
0.005

C
C

5TG8 057-3
5TG8 057-4

1
1

5 units
5 units

027
027

0.005
0.005

C
C
C

5TG8 058-0
5TG8 058-1
5TG8 058-2

1
1
1

5 units
5 units
5 units

027
027
027

0.005
0.005
0.005

C
C

5TG8 058-3
5TG8 058-4

1
1

5 units
5 units

027
027

0.005
0.005

Red, transparent
(1 set = 5 units)

5TG8 061

1 set

027

0.004

Green, transparent
(1 set = 5 units)

5TG8 062

1 set

027

0.001

Yellow, transparent
(1 set = 5 units)

5TG8 063

1 set

027

0.004

Blue, transparent
(1 set = 5 units)

5TG8 064

1 set

027

0.003

White, transparent
(1 set = 5 units)

5TG8 066

1 set

027

0.003

Red and green


(1 set = 10 lamps per color),
yellow, blue and white
(1 set = 5 lamps per color)

5TG8 067

1 set

027

0.011

Red, green, yellow


(1 set = 3 units)

5TG8 070

1 set

027

0.007

Green
Blue
White
Red
Yellow

0.4

115 AC/DC

Green
Blue
White
Red
Yellow

0.4

230 AC

Green
Blue
Cap sets for manual changing of colored caps

* You can order this quantity or a multiple thereof.

8/14

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
ON/OFF switches

Overview
The devices are used for the switching of lighting, motors and
other electrical devices.

The ON/OFF switches in the rated currents 32 A to 125 A can be


used as switch disconnectors according to IEC/EN 60947-3.

The rated currents of the range are 20 A to 125 A. There is a


compact series of space-saving devices with up to 4 NO contacts in a single MW available for rated currents 20 A and 32 A.

A special version of the ON/OFF switch with rated current 63 A


is available for use in meter cabinets. This version can be locked
in the "OFF" position using a special key. The clamping screws
are mechanically covered so that they are no longer accessible.

Benefits

8
The switches can be retrofitted with auxiliary switches without
the need for tools
Uniform auxiliary switches for miniature circuit breakers and
switches. So no need to stock-keep additional components.

Clear and visible conductor connection in front of the busbar


for safe and easy mounting.
The infeed can be either from the top or the bottom as the
terminals are identical. This simplifies connection.

The 20 A and 32 A switches can be bus-mounted with each


other or with 5TE4 8 pushbuttons, 5TE5 8 light indicators or
5TT4 1 remote control switches and 5TT4 2 switching relays.
This saves time and space
For busbars, see page 8/22.

Spacers can be used as a compensating element and have a


width of 0.5 MW. They come with an integrated wiring duct for
the insertion of conductors.
Two oppositely installed spacers thus offer space for large
conductor cross-sections up to a 15 mm diameter. This simplifies cable routing in the distribution board.
The handle locking device is a universal accessory for all
switches and miniature circuit breakers. This simplifies
logistics.

The handle locking device prevents undesired manual on and


off switching. This increases operational safety.

Siemens LV 10.1 2011

8/15

Siemens AG 2011

Switching Devices
ON/OFF switches

Technical specifications
Standards

5TE8 2

IEC/EN 60947-3;
IEC/EN 60669-1

IEC/EN 60947-3

EN 60669-1

Approvals
Rated operational current Ie

Per conducting path

20

Rated operational voltage Ue

1-pole
Multipole

V AC
V AC

230
400

Rated power dissipation Pv

Per pole, max.

VA

0.7

32

20

32

Rated breaking capacity

At p.f. = 0.65

60

96

Rated making capacity

At p.f. = 0.65

60

96

Rated short-circuit making capacity Icm


In conjunction with fuse of the same rated
operational current

EN 60269 gL/gG

kA

10

kV

>5

Open contacts
Between the poles

mm
mm

2>2
>7

Creepage distances

mm

>7

Mechanical service life

Switching 25000
cycles

Electrical service life

Switching 10000
cycles

Minimum contact load

V; mA

10; 300

A
A
A
A

650
400
290
170

Nm

1
1.2

mm2
mm2

1.5 ... 6
1 ... 6

-5 ... +40

45

Conventional free-air thermal current Ith

Rated impulse withstand voltage Uimp


Clearances

5TE8 1

Rated short-time withstand current Icw


Per conducting path at p.f. = 0.7
(The corresponding rated surge current can be
established by multiplying by factor 1.5.)

Up to 0.2 s
Up to 0.5 s
Up to 1 s
Up to 3 s

Terminals
Max. tightening torque

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Permissible ambient temperature


Resistance to climate
At 95 % relative humidity

8/16

Siemens LV 10.1 2011

Acc. to DIN 50015

1000
630
450
250

Siemens AG 2011

Switching Devices
ON/OFF switches
5TE8 3

5TE8 4

5TE8 5

5TE8 6

5TE8 7

5TE8 8

IEC/EN 60947-3

Standards

--

IEC/EN 60669-1

--

EN 60669-1

Approvals
Rated operational current Ie

Per conducting path

Rated operational voltage Ue

1-pole
Multipole

V AC
V AC

Rated power dissipation Pv

Per pole, max.

VA

Conventional free-air thermal current Ith

32

40

63

80

100

125

230
400
0.7

0.9

2.2

3.5

5.5

8.6

32

40

63

80

100

125

Rated breaking capacity

At p.f. = 0.65

96

120

196

240

300

375

Rated making capacity

At p.f. = 0.65

96

120

196

240

300

375

Rated short-circuit making capacity Icm


In conjunction with fuse of the same
rated operational current

EN 60269 gL/gG

kA

10

kV

>5

Open contacts
Between the poles

mm
mm

>7
>7

Creepage distances

mm

>7

Mechanical service life

Switching 20000
cycles

Electrical service life

Switching 10000
cycles

5000

1000

Minimum contact load

V; mA

24; 300

1-pole
2-pole
3-/4-pole

kW
kW
kW

5
9
15

6.5
11
15

10
18
30

13
22
39

16
28
48

16
28
48

Up to 0.2 s
Up to 0.5 s
Up to 1 s
Up to 3 s

A
A
A
A

760
500
400
280

950
630
500
350

1500
1000
800
560

2700
1650
1350
800

3400
2100
1700
1000

3400
2100
1700
1000

Nm

2
3.5

mm2
mm2

1 ... 35
1 ... 35

-5 ... +40

45

Rated impulse withstand voltage Uimp


Clearances

Rated power
Switching of resistive loads
including moderate overload AC-21
Rated short-time withstand current Icw
Per conducting path at p.f. = 0.7
(The corresponding rated surge current can be
established by multiplying by factor 1.5.)
Terminals
Max. tightening torque

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Permissible ambient temperature


Resistance to climate
At 95 % relative humidity

Acc. to DIN 50015

2.5 ... 50
2.5 ... 50

Selection and ordering data


Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

ON/OFF switches (20 A and 32 A)


With sealable switch position,
separate handle locking device can be retrofitted,
Mountable auxiliary switch
1 NO
20
230
32
2 NO
20
400
32

}
B
}
}
B
B

5TE8 111
5TE8 211
5TE8 112
5TE8 212
5TE8 113
5TE8 213

1 1/12 units
1
1 unit
1
1 unit
1
1 unit
1
1 unit
1
1 unit

027
027
027
027
027
027

0.068
0.066
0.075
0.076
0.086
0.086

B
}

5TE8 114
5TE8 214

1
1

1 unit
1 unit

027
027

0.094
0.094

1.5

B
B

5TE8 118
5TE8 218

1
1

1 unit
1 unit

027
027

0.138
0.143

Auxiliary switch cannot be retrofitted


3 NO + N
20
400
6
32
With mounted auxiliary switch
3 NO + N
20
400
32

3 NO

20
32

400

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/17

Siemens AG 2011

Switching Devices
ON/OFF switches
Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

ON/OFF switches (32 A to 125 A)


Can be used as switch disconnector
According to EN 60947-1
With sealable switch position, separate handle locking
device can be retrofitted, auxiliary switches can be retrofitted
1 NO, red handle

63
100

1 NO, gray handle

32
40
63
80
100
125

230

B
B

5TE8 521
5TE8 721

1
1

1 unit
1 unit

027
027

0.108
0.110

35

B
B
B

5TE8 311
5TE8 411
5TE8 511

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.113
0.113
0.117

50

B
B
B

5TE8 611
5TE8 711
5TE8 811

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.124
0.123
0.124

B
B

5TE8 522
5TE8 722

1
1

1 unit
1 unit

027
027

0.195
0.216

63
100

2 NO, gray handle

32
40
63

35

}
}
}

5TE8 312
5TE8 412
5TE8 512

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.215
0.216
0.215

80
100
125

50

B
B
B

5TE8 612
5TE8 712
5TE8 812

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.237
0.240
0.229

B
B

5TE8 523
5TE8 723

1
1

1 unit
1 unit

027
027

0.321
0.355

400

35
50

2 NO, red handle

400

35
50

3 NO, red handle

63
100

3 NO, gray handle

32
40
63

35

}
}
}

5TE8 313
5TE8 413
5TE8 513

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.321
0.320
0.321

80
100

50

}
}

5TE8 613
5TE8 713

1
1

1 unit
1 unit

027
027

0.337
0.355

B
B

5TE8 524
5TE8 724

1
1

1 unit
1 unit

027
027

0.430
0.476

35
50

3 NO+ N, red
handle

63
100

3 NO+ N, gray
handle

32
40
63

35

}
}
}

5TE8 314
5TE8 414
5TE8 514

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.428
0.430
0.426

80
100
125

50

}
}
}

5TE8 614
5TE8 714
5TE8 814

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.475
0.476
0.477

32
40
63

35

B
B
B

5TE8 315
5TE8 415
5TE8 515

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.424
0.434
0.436

80
100
125
125

50

B
B
B
B

5TE8 615
5TE8 715
5TE8 815
5TE8 813

1
1
1
1

1 unit
1 unit
1 unit
1 unit

027
027
027
027

0.479
0.481
0.482
0.357

5TE8 533

1 unit

027

0.311

1 NO + 1 NC
2 NO
2 NC

0.5
0.5
0.5

}
A
A

5ST3 010
5ST3 011
5ST3 012

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.066
0.055
0.055

Auxiliary switches for small output


1 NO + 1 NC
2 NO
2 NC

0.5
0.5
0.5

}
B
B

5ST3 013
5ST3 014
5ST3 015

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.055
0.054
0.060

4 NO, gray handle

400

35
50

ON/OFF switches 63 A
Can be used as switch disconnector
According to EN 60947-1
Terminal access from the bottom and off-position lockable
with special key (exclusive power supply company tool)
Reduced lower terminal entry for conductors with
approx. 7 mm diameter
3 NO

63

400

35

Auxiliary switches (AS)


for all 5TE8 switches,
for right-side retrofitting with factory-fitted brackets,
for further technical specifications, see also
Section "Miniature circuit breakers"

* You can order this quantity or a multiple thereof.

8/18

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
ON/OFF switches
Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Handle locking devices


For all 5TE8 switches,
can be sealed against unwanted manual
ON/OFF switching,
for padlock with max. 3 mm shackle

5ST3 801

1 unit

027

0.012

5ST3 800

1 10 units

027

0.002

Terminal covers
For all 5TE8 5 to 5TE8 8 switches,
in 1 MW per pole version,
for covering screw openings,
sealable
Spacers

Contour for modular devices with a mounting


depth of 70 mm;
can be snapped onto either side of the busbar,
so that two spacers allow for convenient cable
routing
0.5

5TG8 240

2 units

027

0.010

5TE9 112

1 unit

027

0.114

5TE9 113

1 unit

027

0.114

Phase connectors
For easier wiring in various wiring versions
and bus mountings or as a fixpoint terminal for conductors from 2.5 mm2 to 50 mm2
1P

125

230

50

N-conductor connectors
For easier wiring in various wiring versions
and bus mountings or as a fixpoint terminal for N conductors from 2.5 mm2 to 50 mm2 with blue color marking
1P

125

230

50

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/19

Siemens AG 2011

Switching Devices
DC isolators

Overview

Benefits
Compact DIN rail device for applications up to 1000 V DC
Separate switching position display for unambiguous indication of the switching state
Compatible with all miniature circuit breaker accessories
reduced stock-keeping
The effective touch protection when grasping the device considerably exceeds the requirements of BGV A3.
Manual snap-on fixing and release systems that require no
tools enable fast assembly and disassembly of switch disconnectors
Clear and visible conductor connection that can be easily
checked in front of the busbar

DIN VDE 0100-712 specifies the use of special switch disconnectors for isolating solar modules in photovoltaic systems. With
a high rated voltage of 1000 V DC, the 5TE2 515-1 switch disconnectors from Siemens go well above and beyond meeting
these requirements.
The optimally coordinated BETA Low-Voltage Circuit Protection
product range which includes DC overvoltage protection and
universal current-sensitive SIQUENCE TYPE B RCCBs enables the quick and easy implementation of standard-conform
protection for photovoltaic systems.

Technical specifications
5TE2 515-1
IEC/EN 60947-3, IEC/EN 60669-1

Standards
Rated operational current Ie

63

Rated operational voltage Ue

For 4 poles in series

V DC

1000

Rated power dissipation Pv

Per pole, max.

4.4

Rated short-circuit strength Icw

1000 V DC, 4-pole

760

Rated short-circuit making capacity Icm

1000 V DC, 4-pole

500

Rated impulse withstand voltage Uimp

kV

>5

Mechanical service life

Switching 10000
cycles

Electrical service life

Switching
cycles

5000
DC-21B

Utilization category
Minimum contact load
Terminals
Max. tightening torque

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Permissible ambient temperature


Resistance to climate
At 95 % relative humidity

Acc. to DIN 50015

V; mA

24; 300

Nm

PZ 2
2.5 ... 3

mm2
mm2

0.75 ... 35
0.75 ... 25

-25 ... +45

45

Selection and ordering data


Version

Ie

Ue

Conductor
crosssections

Mount- DT
ing
width

V AC

Up to mm2

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

DC isolators
1000 V DC,
can be used as switch disconnector according to
EN 60947-1,
with sealable switch position,
separate handle locking device can be retrofitted,
auxiliary switch can be retrofitted
4 NO

63

--

35

5TE2 515-1

1 unit

027

0.672

1 NO + 1 NC
2 NO
2 NC

0.5
0.5
0.5

}
A
A

5ST3 010
5ST3 011
5ST3 012

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.066
0.055
0.055

Auxiliary switches for small output


1 NO + 1 NC
2 NO
2 NC

0.5
0.5
0.5

}
B
B

5ST3 013
5ST3 014
5ST3 015

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.055
0.054
0.060

Auxiliary switches (AS)


for DC isolator 5TE2, for right-side retrofitting with
factory-fitted brackets,
for further technical specifications, see also Section "Miniature circuit breakers"

* You can order this quantity or a multiple thereof.

8/20

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
DC isolators

Configuration

- 5

+ 7

- 1

- 4

+ 6

- 8

+ 2

+ 2

PV

- +
WR

I201_14005

- 1

For this reason it is essential to comply with the polarity specifications of the switches when connecting the conductor. Suitable
precautions should be taken during plant configuration to
ensure there can be no polarity reversal in DC operation
(e.g. photovoltaic plants).

- 5

+ 7

- 4

+ 6

- 8

WR
+ +

I201_14006

For DC voltages up to 1000 V, the four poles need to be connected in series. In contrast to normal flush-mounting switches,
these devices are also fitted with arcing chambers and permanent solenoids to aid the positive quenching of the electric arc in
direct currents.

PV

Legend:
PV: Photovoltaic
WR: Inverter

Siemens LV 10.1 2011

8/21

Siemens AG 2011

Switching Devices
Busbar systems

Overview
Siemens has developed a rail-mounting concept which makes
the linking of switching devices just as easy as that of miniature
circuit breakers.

The arrangement of the terminals on the devices is adapted to


the bus mounting. With only two busbars, this saves considerable mounting time.

Benefits

Uniform bus mounting on many devices


All 5TE8 switches (20 A and 32 A), 5TE4 8 pushbuttons,
5TE5 8 light indicators and 5TT4 1 remote control switches
and 5TT4 2 switching relays can be bus-mounted. This makes
installation tasks considerably easier.

Infeed: The phase busbar is fed in at the tunnel terminal for


conductors up to 6 mm2 up to 32 A. No additional feeder
terminals required.

8/22

Siemens LV 10.1 2011

All 5TE8 switches (20 A and 32 A) in 1 MW can be fed via the


single or two-phase busbars. Thus 2 two-phase busbars
support a 4-pole infeed. This is unique.

Siemens AG 2011

Switching Devices
Busbar systems

Selection and ordering data


Version

Length DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

mm
Single-phase busbars
For all 5TE8, 20 A and 32 A switches

210

5TE9 100

1 10 units

027

0.034

220

5TE9 101

1 10 units

027

0.076

5TE9 102

027

0.001

In the 12 MW version for the cutting of unused


terminal lugs to ensure insulation clearances if
one device terminal is to be supplied separately
despite being mounted on the busbar,
modular clearance = 1 MW
Busbar infeed to unit terminal with conductor
cross-section of 6 mm2 up to 32 A
Can be mounted top or bottom in the front or
rear terminal area
Note:
An end cap is not required on single-phase
busbars.
Two-phase busbars
For all 5TE8, 20 A and 32 A switches
In 12 MW version with 1 MW division, whereby
the two busbars are offset by 0.5 MW
Both copper conductors of the two-phase busbar are insulated together.
Busbar infeed to unit terminal with conductor
cross-section of 6 mm2 up to 32 A
Can be mounted from top or bottom, or in the
front or rear terminal area, thus allowing realization of a 4-conductor connection using two twophase busbars.
End caps for two-phase busbars
End caps for 5TE9 101 two-phase busbars to
keep insulation clearances when the bar is
being cut.

1 set

1 set = 10 units
5ST3 6 and 5ST3 7 busbar systems
All busbars of the 5ST3 6 and 5ST3 7 busbar
systems can also be used for all 5TE8 switches
from 32 A to 125 A in 1 MW per pole versions
(see chapter "Miniature Circuit Breakers").

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/23

Siemens AG 2011

Switching Devices
Remote control switches

Overview

Benefits

Remote control switches are used in residential and non-residential buildings, as well as the switchgear engineering sector.
They trip in the event of current inrushes, i.e. pulses, and then
electromechanically save the switching position (i.e. without
auxiliary power), even in the event of a power failure. In residential and non-residential buildings, used in conjunction with pushbuttons, they facilitate installation of systems where, for example, a corridor light needs to be switched from more than one
location. Because they save the switching position without
standby losses, they enable the energy-efficient control of
lighting.
With special functions, such as central and group control, or
series and shutter/blind control sequences, even high feature
control tasks can be implemented easily and energy-efficiently.
All the devices have the VDE mark and can also be equipped
with an additional auxiliary switch. All devices have a switching
position indicator and are operated manually. The switching
noise is particularly quiet and meets the requirements of residential buildings.

Note:
Busbars to match the 5TT4 1 remote control switch can be found
on page 8/22.

8/24

Siemens LV 10.1 2011

All the devices have the VDE mark. This increases operational
safety.
Remote control switches with central/group switching support
convenient and high feature applications
High functional reliability due to electromechanical design
without fault-prone electronics
The devices have no standby losses
All devices have a switching position indicator and are operated manually. This enables simple on-site operation and fast
recognition of the switching state.
The remote control switches can be bus-mounted on
5TE9 100 and 5TE9 101 busbars; e.g.: bus mounting of the
N conductor and/or infeed.
All the remote control switches can be fitted with an additional
auxiliary switch. This increases application flexibility.

Siemens AG 2011

Switching Devices
Remote control switches

Technical specifications
Remote control switches
5TT4 101
5TT4 102
5TT4 105
5TT4 115

5TT4 103
5TT4 104

Auxiliary switches
5TT4 12
5TT4 15

5TT4 13
5TT4 14

Standards

IEC 60669-1, IEC 60669-2, IEC 60669-3,


EN 60669, EN 60669-2-2, EN 60669-2-2/A1

Approvals

VDE 0632

Contact type

1 NO
2 NO
1 NO 1 NC

Manual operation

Yes

Switching position indication

Yes

3 NO
4 NO

1 NO
2 NO
3 NO
1 NO 1 NC

Series
Shutter/
blind

5TT4 900

5TT4 901

1 CO

1 CO

---

Rated control voltage Uc

V AC
V DC

8 ... 230
12 ... 110

---

Primary operating range

Uc

0.8 ... 1.1

--

Rated frequency fc (AC types)

Hz

50

--

Rated impulse withstand voltage Uimp

kV

Magnet coil, only pulse


Per contact at 16 A

W/VA
W

4.5/7
1.2

Minimum contact load

V AC; mA 10; 100

10; 100

5 AC/DC; 1

Rated operational current Ie at p.f. = 0.6 ... 1

16

0.1

V AC
V AC
V AC
V AC
V AC

250
400
--250

250
-----

30 AC/DC

Rated power dissipation Pv


9/13

4.5/7

---

Rated operational voltage Ue

1 NO
2 NO
3 NO
4 NO
1 NO + 1 NC

--400
400
--

250
400
400
-250

-250
----

Glow lamp load at 230 V

mA

--

With one 5TT4 920 compensator


With two 5TT4 920 compensators

mA
mA

25
45

---

Incandescent lamp load

2400

--

Permissible

--

> 1.2

< 1.2

Different phases between magnet coil/contact


mm

Contact gap

Safe separation
Creepage distances and clearances between magnet coil/contact mm

>6

Pushbutton malfunction
Protected against continuous voltage, safe due to design

Yes

Minimum pulse duration

ms

Electrical service life


At Ie/Ue or specified lamp load

In switching cycles 50000

Terminals screw (Pozidriv)

Acc. to DIN 50015

Permissible ambient temperature


Degree of protection
Mounting position
1)

Yes1)

Yes

--

50

Conductor cross-sections
Rigid
Flexible, with end sleeve
Resistance to climate
At 95 % relative humidity

PTC

Acc. to EN 60529

mm2
mm2

1.5 ... 6
1 ... 6

35

-10 ... +40

0.5 ... 4
0.75 ... 4

IP20, with connected conductors


Any

For 2.5 MW 5TT4 123-0 devices with PTC.

Siemens LV 10.1 2011

8/25

Siemens AG 2011

Switching Devices
Remote control switches

Selection and ordering data


Contacts

Ue

Ie

Uc

Uc

Mount- DT
ing
width

V AC

A AC

V AC

V DC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Remote control switches,


auxiliary switches can be retrofitted
1 NO

250

16

230
115
24
12
8

}
B
}
B
B

5TT4 101-0
5TT4 101-1
5TT4 101-2
5TT4 101-3
5TT4 101-4

1 1/12 units
1
1 unit
1
1 unit
1
1 unit
1
1 unit

027
027
027
027
027

0.135
0.138
0.134
0.133
0.128

2 NO

400

16

230
115
24
12
8

}
B
}
B
B

5TT4 102-0
5TT4 102-1
5TT4 102-2
5TT4 102-3
5TT4 102-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.144
0.150
0.144
0.145
0.141

3 NO

16

230
24

}
}

5TT4 103-0
5TT4 103-2

1
1

1 unit
1 unit

027
027

0.199
0.198

4 NO

16

230
24

}
}

5TT4 104-0
5TT4 104-2

1
1

1 unit
1 unit

027
027

0.211
0.210

230
115
24
12
8

}
B
}
B
B

5TT4 105-0
5TT4 105-1
5TT4 105-2
5TT4 105-3
5TT4 105-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.144
0.151
0.144
0.145
0.140

}
}
}

5TT4 115-1
5TT4 115-2
5TT4 115-3

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.144
0.147
0.144

5TT4 121-0

1 unit

027

0.155

5TT4 121-2

1 unit

027

0.165

5TT4 122-0

1 unit

027

0.163

5TT4 122-2

1 unit

027

0.175

8
1 NO + 1 NC

250

16

1 NO + 1 NC

250

16

110
24
12

Remote control switches with central ON/OFF switching,


auxiliary switch cannot be retrofitted
1 NO

250

16

230

1.5

24
2 NO

400

16

230

1.5

24
3 NO

400

16

230

2.5

5TT4 123-0

1 unit

027

0.227

1 NO + 1 NC

250

16

230

1.5

5TT4 125-0

1 unit

027

0.163

Remote control switches, with central and group ON/OFF


switching, auxiliary switch cannot be retrofitted
1 NO

250

16

230
24

1.5
1.5

}
}

5TT4 151-0
5TT4 151-2

1
1

1 unit
1 unit

027
027

0.145
0.144

2 NO

400

16

230
24

1.5
1.5

}
}

5TT4 152-0
5TT4 152-2

1
1

1 unit
1 unit

027
027

0.156
0.155

}
}

5TT4 132-0
5TT4 132-3

1
1

1 unit
1 unit

027
027

0.143
0.130

}
B
C

5TT4 142-0
5TT4 142-2
5TT4 142-3

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.144
0.145
0.143

Series remote control switches


Contact sequence 1 - 2 - 1+2 - 0
auxiliary switch cannot be retrofitted
2 NO

250

16

230
12

Blinds remote control switches


Contact sequence 1 - 0 - 2 - 0
auxiliary switch cannot be retrofitted
2 NO

250

16

230
24
12

* You can order this quantity or a multiple thereof.

8/26

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Remote control switches
Contacts

Ue

Ie

Mount- DT
ing
width

V AC

A AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Auxiliary switches
One device can be retrofitted per remote control switch
1 CO
250 V AC/5 A

250

1 CO
For small outputs

30 AC/DC 0.1

0.5

5TT4 900

1 unit

027

0.049

0.5

5TT4 901

1 unit

027

0.050

5TT4 920

1 unit

027

0.073

Compensators
For increasing the glow lamp load by 20 mA
250

--

8
More information
Mechanical storage

Busbar mounting

Remote control switches are used to switch lighting by means of


several pushbuttons. This makes complex cross/two-way
switching unnecessary. With each pushbutton impulse, the remote control switch changes its contact position from "OFF" to
"ON", etc. In the event of a power failure, the last switching position is mechanically stored. Electromechanical remote control
switches have no standby loss.
Pushbutton malfunction
Pushbuttons can jam, which may expose remote control
switches to a continuous voltage. All remote control switches are
protected against this type of malfunction through their design or
through PTC.
Central switching functions
Versions with central ON/OFF function allow the central switching of all connected remote control switches. This type of central
switching can also be actuated using a time switch. All remote
control switches can be switched to the ON or OFF switching
state, regardless of their current switching state.
Contact sequences

All 5TT4 1 remote control switches can be bus-mounted with


each other. This saves time and space.
Note:
Busbars to match the 5TT4 1 remote control switch can be found
on page 8/22.

1 2 1+2 0 or 1 - 0 - 2 - 0 means:

0: No contact closed
1: Only contact 1 closed
2: Only contact 2 closed
1+2: Contact 1 and Contact 2 are closed
The contact positions are constantly changing with each pushbutton impulse.
Note:
Synchronous switching of the contacts cannot be guaranteed
with parallel switching. Products with central/group switching
must be used for the mutual control of several remote control
switches.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/27

Siemens AG 2011

Switching Devices
Switching relays

Overview

Benefits
Fast and simple installation thanks to bus-mounting
Switching position indicator when checking the plant for
enhanced safety
Manual intervention possible at any time easy fault locating
due to manual operation.

Switching relays are used in residential, non-residential and industrial buildings for the purpose of contact multiplication. They
can be used with safe isolation between coil voltage and contact. Switching relays for direct voltages in particular are seeing
increasing use.
With the 5TE9 100 and 5TE9 101 busbar, the switching relays
can be mounted quickly and safely, e.g. by bus-mounting the
N-conductor and/or infeed and this applies to the whole range
of switching relays.
Note:
Busbars to match the 5TT4 2 switching relay can be found on
page 8/22.

Technical specifications
5TT4 201-.

5TT4 202-.

5TT4 204-.

Standards

EN 60947-5-1, EN 60669-2-2

Contact type

1 NO

Manual operation

Yes

Rated control voltage Uc

V AC
V DC

8 ... 230
--

Primary operating range

Uc

0.8 ... 1.1

Rated frequency fc

Hz

50

Rated impulse withstand voltage Uimp

kV

Rated power dissipation Pv


Magnet coil
Per contact at 16 A

W/VA
W

2.4/3.0
1.0

Minimum contact load

V AC; mA 10; 100

Rated operational current Ie


At p.f. = 0.6 ... 1

Different phases
Between magnet coil/contact

4 NO

mm

> 1.2

Safe separation
Between creepage distances and clearances
magnet coil/contact

mm

>6

At Ie/Ue or specified lamp load

Acc. to DIN 50015

Permissible ambient temperature


Degree of protection

Acc. to EN 60529

Mounting position

8/28

Siemens LV 10.1 2011

5TT4 217-.

2 CO

2 CO

2.4/3.0

4.8/6.0

2.4/3.0

2.4/3.0

2.4/3.0

1.7

400

400

400

250

400

400

Switch50000
ing cycles

screw (Pozidriv)

Conductor cross-sections
Rigid
Flexible, with end sleeve

5TT4 207-.

-12 ... 110

Electrical service life

Resistance to climate
At 95 % relative humidity

1 NO + 1 NC 1 CO

Permissible

Contact gap

Terminals

5TT4 206-.

16
250

Rated operational voltage Ue

2 NO

5TT4 205-.

1
mm2
mm2

1.5 ... 6
1 ... 6

35

-10 ... +40


IP20, with connected conductors
Any

< 1.2

Siemens AG 2011

Switching Devices
Switching relays

Selection and ordering data


Contacts

Ue

Ie

Uc

Uc

Mount- DT
ing
width

V AC

A AC

V AC

V DC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Switching relays for AC voltage


1 NO

250

16

230
115
24
12
8

}
B
}
}
}

5TT4 201-0
5TT4 201-1
5TT4 201-2
5TT4 201-3
5TT4 201-4

1 1/12 units
1
1 unit
1
1 unit
1
1 unit
1
1 unit

027
027
027
027
027

0.130
0.138
0.132
0.131
0.129

2 NO

400

16

230
115
24
12
8

}
B
}
B
B

5TT4 202-0
5TT4 202-1
5TT4 202-2
5TT4 202-3
5TT4 202-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.143
0.147
0.142
0.142
0.139

4 NO

400

16

230
115
24
12
8

A
B
A
B
B

5TT4 204-0
5TT4 204-1
5TT4 204-2
5TT4 204-3
5TT4 204-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.266
0.276
0.278
0.262
0.261

1 NO +
1 NC

400

16

230
115
24
12
8

A
B
}
B
B

5TT4 205-0
5TT4 205-1
5TT4 205-2
5TT4 205-3
5TT4 205-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.142
0.147
0.144
0.142
0.139

1 CO

250

16

230
115
24
12
8

}
B
}
B
B

5TT4 206-0
5TT4 206-1
5TT4 206-2
5TT4 206-3
5TT4 206-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.135
0.140
0.137
0.136
0.137

2 CO

400

16

230
115
24
12
8

A
B
}
B
B

5TT4 207-0
5TT4 207-1
5TT4 207-2
5TT4 207-3
5TT4 207-4

1
1
1
1
1

1 unit
1 unit
1 unit
1 unit
1 unit

027
027
027
027
027

0.149
0.153
0.150
0.145
0.147

}
}
A
}

5TT4 217-1
5TT4 217-6
5TT4 217-2
5TT4 217-3

1
1
1
1

1 unit
1 unit
1 unit
1 unit

027
027
027
027

0.150
0.135
0.152
0.145

5TG8 240

2 units

027

0.010

Switching relays for direct voltage


2 CO

400

16

110
30
24
12

Spacers
In the case of higher ambient temperatures, we 0.5
recommend placing a spacer after every second
switching relay for better heat dissipation.

More information
Busbar mounting
All 5TT4 2 switching relays can be bus-mounted with each
other. This saves time and space.
Note:
Busbars to match the 5TT4 2 switching relay can be found on
page 8/22.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/29

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, DC technology

Overview
Insta contactors are standard devices in installation technology
and belong to the BETA switching device range. Insta contactors are particularly suitable for switching heating, lighting and
motors.
While Insta contactors have seen a considerable decline in use
in the electrical heating sector in residential buildings, they have
gained considerable significance for lighting circuits in buildings. Insta contactors are increasingly used in industry for
motors where distribution technology plays a major role, e.g. in
auxiliary installations for heat pumps and air conditioning technology.

In addition to their basic function, they can also be used for the
ON/OFF switching of single-phase and three-phase electrical
motors.
The 5TT5 7 Insta contactors meet the requirements of EN 60947
and are approved to UL 508.

Benefits

Safe cable routing through the cable entry funnel - saves time
during installation.
The insulation goes right through into the cable entry funnel thus ensuring maximum touch protection.

8/30

Siemens LV 10.1 2011

Switching position indicator for fast recognition of operating


state offers greater safety when checking the plant.

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, DC technology

Technical specifications
5TT5 73
4-pole

5TT5 74
4-pole

5TT5 75
4-pole

EN 60947-4-1; EN 60947-5-1; EN 61095; UL 508


UL 508; UL File No. E303328

Standards
Approvals
Rated frequency at AC fn

Hz

40 ... 450

Rated control voltage Uc

V AC
V DC

24, 115, 230


24, 110, 220

Primary operating range

Uc

0.85 ... 1.1

Rated operational voltage Ue

440

Rated operational current Ie


AC-1/AC-7a, NO contacts
AC-1/AC-7a, NC contacts
AC-3/AC-7b, NO contacts
AC-3/AC-7b, NC contacts

At V AC
A
A
A
A

Acc. to UL 480; acc. to IEC 440


24
40
24
30
9
22
6
--

63
30
30
--

Rated power dissipation Pv


Pick-up power
Holding power
Per contact AC-1/AC-7a

VA/W
VA/W
VA

4/4
4/4
1.5

5/5
5/5
3

6.5/6.5
4.2/4.2
6

Switching times
Closing (NO contacts)
Opening (NO contacts)

ms
ms

 40
 40

Rated impulse withstand voltage Uimp

kV

4

Contact gap (S contacts) min.

mm

2.4

2.8

2.6

For switching
cycles
For switching
cycles

150000
170000

240000

For switching
cycles

1 million

Switching
cycles/h
Switching
cycles/h

300

V AC

230

kW
kW

5.3
16

8.8
26

13.8
41

11

15

Electrical service life


At Ie and load

AC-1/AC-7a
AC-3/AC-7b

Mechanical service life


Maximum switching frequency
At load

AC-1/AC-7a
AC-3/AC-7b

Switching of resistive loads AC-1


For rated operational power Ps (NO contacts)
Single-phase
Three-phase

500000

24, 230
24, 220

600

Switching of three-phase asynchronous motors AC-3


for rated operational power Ps (NO contacts)
Single-phase
Three-phase

V AC

400

kW
kW

-4

Minimum switching capacity

V; mA

 17;  200

72

176

240

35

63

80

1
1

1
2

1
2

0.9
2.5

0.9
2.5

Overload withstand capability


Per conducting path (NO contacts only)

At 10 s

Short-circuit protection, according to coordination type 1


Back-up fuse characteristic gL/gG
Terminals
Coil connection
Main connection

screw (Pozidriv)

Tightening torques
Coil connection
Main connection

Nm
Nm

0.9
1.0

Conductor cross-sections
Coil connection
- Solid
- Stranded, with end sleeve
- AWG cables
Tightening torques

mm2
mm2
AWG
lb. in

1.5 ... 4
1.5 ... 2.5
16 ... 10
8

Main connection
- Solid
- Stranded, with end sleeve
- AWG cables
Tightening torques

mm2
mm2
AWG
lb. in

1.5 ... 10
1.5 ... 2.5
16 ... 8
9

Permissible ambient temperature


For operation
For storage

C
C

-25 ... +55


-50 ... +80

Degree of protection

Acc. to EN 60529

According to UL 508
UL 508 General Use 240 V/480 V
UL 508 AC discharge lamps
UL 508 motor load 240 V
UL 508 motor load 480 V
UL 508 Short-circuit at 480 V

In
FLA
Power
Power
K5 fuses

2.5 ... 25
2.5 ... 16
16 ... 4
20

IP20, with connected conductors


A
A
A
hp
hp
A
kA

24
24
24
3
5
25
5

40
40
30
7.5
15
40

63
63
40
10
15
75

Siemens LV 10.1 2011

8/31

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, DC technology

Selection and ordering data


Contacts

Ue

Ie

Uc

V AC

A AC

V AC

Mount- DT
ing
width
V DC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Insta contactors
For AC or DC continuous operation,
with switching position indication,
with DC magnetic system
4 NO

5TT5 730-0

440

24

230
115
24

220
110
24

A
B
A

5TT5 730-0
5TT5 730-1
5TT5 730-2

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.260
0.261
0.267

3 NO + 1 NC 440

24

230
24

220
24

A
A

5TT5 731-0
5TT5 731-2

1
1

1 unit
1 unit

027
027

0.259
0.266

2 NO + 2 NC 440

24

230
24

220
24

A
A

5TT5 732-0
5TT5 732-2

1
1

1 unit
1 unit

027
027

0.261
0.264

4 NC

440

24

230
24

220
24

A
B

5TT5 733-0
5TT5 733-2

1
1

1 unit
1 unit

027
027

0.257
0.265

4 NO

440

40

230
24

220
24

A
A

5TT5 740-0
5TT5 740-2

1
1

1 unit
1 unit

027
027

0.434
0.446

3 NO + 1 NC 440

401)

230
24

220
24

A
B

5TT5 741-0
5TT5 741-2

1
1

1 unit
1 unit

027
027

0.437
0.447

2 NO + 2 NC 440

401)

230
24

220
24

A
B

5TT5 742-0
5TT5 742-2

1
1

1 unit
1 unit

027
027

0.435
0.446

4 NO

63

230
24

220
24

A
A

5TT5 750-0
5TT5 750-2

1
1

1 unit
1 unit

027
027

0.443
0.446

3 NO + 1 NC 440

63

1)

230
24

220
24

B
B

5TT5 751-0
5TT5 751-2

1
1

1 unit
1 unit

027
027

0.445
0.441

2 NO + 2 NC 440

631)

230
24

220
24

B
B

5TT5 752-0
5TT5 752-2

1
1

1 unit
1 unit

027
027

0.441
0.451

5TT5 900

1 unit

027

0.059

5TT5 901

1 unit

027

0.059

5TG8 240

1 2 units

027

0.010

5TT5 902

1 set

027

0.007

5TT5 903

1 set

027

0.008

440

5TT5 740-0

Auxiliary switches
For installation on the left of Insta contactors 24 A, 40 A
and 63 A, max. one auxiliary current switch per Insta
contactor, minimum contact load AC 24 V; 5 mA.
2 NO
230
4
0.5
AC-15
1 NO + 1 NC 230
4
0.5
AC-15

Spacers
For heat dissipation between the Insta contactors. 0.5
We recommend placing a spacer after every
second Insta contactor.
Can be mounted reciprocally, so that two spacers
enable greater cable routing.

Sealable terminal covers


For Insta contactors 24 A,
(1 set = 2 units)
For Insta contactors 40 A and 63 A
(1 set = 2 units)
1)

For NC contacts 30 A.

* You can order this quantity or a multiple thereof.

8/32

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, AC technology

Overview
The 5TT5 8 Insta contactors are equipped with an AC magnetic
system and are ideal for use under harsh conditions. The auxiliary switches can be mounted without tools. When equipped
with terminal covers, the devices can also be sealed.

Insta contactors without manual switch


Insta contactors are playing an ever growing role in lighting circuits in buildings Insta contactors are increasingly used in industry for motors where distribution technology plays a major role,
e.g. in installations for heat pumps and air conditioning technology. In addition to their basic function, they can also be used for
the ON/OFF switching of single-phase and three-phase electrical motors.
Insta contactors with manual switch
A key feature of Insta contactors with manual operation is the
fact that users can switch consumers/loads on and off by hand.

Benefits

Extremely long service life of 3 million switching cycles is a


testimony to their reliability
Safe cable entry through cable entry funnel - saves time
during assembly
Insulated right through to the cable entry funnel. This provides
enhanced touch protection
Auxiliary switches can be retrofitted on all versions even on
the 20 A type. More functionality when using the devices.

Insta contactors with O/I/Automatic function enable the testing


of a plant by manual switch without the need to apply a control
voltage
Switching position indicator for fast recognition of operating
state offers greater safety when checking the plant.

Siemens LV 10.1 2011

8/33

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, AC technology

Technical specifications
Insta contactors
5TT5 80.

5TT5 84.

5TT5 85.

5TT5 910

IEC 60947-4-1, IEC 60947-5-1, IEC 61095;


EN 60947-4-1, EN 60947-5-1, EN 61095
EN 61095

Standards
Approvals

Number of poles

5TT5 82.,
5TT5 83.

Auxiliary
switches

24, 115, 230

24, 230

24, 230

--

Rated frequency at AC

Hz

50/60

Rated control voltage Uc

V AC

24, 230

Primary operating range

Uc

0.85 ... 1.1

Rated operational voltage Ue

V AC

230

400

Rated operational current Ie

20

25

40

-230/400
63

6/4 (230/400 V)

Rated power dissipation Pv


Pick-up power (without manual switch
or manual switch in "I" position)
Pick-up power (with manual switch in "AUTO" position)
Holding power
Per contact

VA/W

6/3.8

10/5

15.4/6

--

VA/W
VA/W
VA

12/10
2.8/1.2
1.7

33/25
5.5/1.6
2.2

62/50
7.7/3
4

----

Switching times
Closing (NO contacts)
Opening (NO contacts)
Closing (NC contacts)
Opening (NC contacts)

ms
ms
ms
ms

15 ... 25
20
20 ... 30
10

10 ... 20
20
20 ... 30
10

15 ... 20
10
5 ... 10
10 ... 15

Rated impulse withstand voltage Uimp

kV

Rated insulation voltage Ui

440

500

Contact gap, minimum

mm

3.6

3.4

Electrical service life


At Ie and load
AC-1/AC-7a
AC-3/AC-7b

For switching
cycles

200000
300000

500000

100000
150000

---

For switching
cycles

3 million

In switching
cycles/h

600

kW
kW

4
--

5.4
16

8.7
26

13.3
40

---

1.31)
--

1.3
4

3.7
11

5
15

---

Mechanical service life


Maximum switching frequency
At load
Switching of resistive loads AC-1/AC-7a
For rated operational power Ps
Single-phase 230 V
Three-phase 400 V

Switching of three-phase asynchronous motors AC-3/AC-7b


For rated operational power Ps
Single-phase 230 V
kW
Three-phase 400 V
kW

-----

V; mA

17; 50

72

68

176

240

--

Short-circuit protection, according to coordination type 1


Back-up fuse characteristic gL/gG
A

20

25

63

80

Minimum switching capacity


Overload withstand capability
Per conducting path
(NO contacts only)

Terminals
Coil connection
Main connection

At 10 s

screw (Pozidriv)

Tightening torques
Coil connection
Main connection
Conductor cross-sections
Coil connection
Main connection

Rigid
Flexible,
with end sleeve
Rigid
Flexible,
with end sleeve

Permissible ambient temperature


For operation
For storage
Degree of protection
1)

Acc. to EN 60529

For NO contacts only.

8/34

12; 5

Siemens LV 10.1 2011

1
1

1.2
3.5

-1

Nm
Nm

0.6
1.2

-0.8

mm2
mm2

1.0 ... 2.5


1.0 ... 2.5

mm2
mm2

1.0 ... 10
1.0 ... 6

C
C

-5 ... +55
-30 ... +80

--1 ... 25
1 ... 16

IP20, with connected conductors

1 ... 2.5
1 ... 2.5

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, AC technology

Selection and ordering data


Version

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Insta contactors without manual switch


For alternating current continuous operation,
with switching position indication,
with AC magnetic system

5TT5 800-0

}
}

5TT5 800-0
5TT5 800-2

1
1

1 unit
1 unit

027
027

0.143
0.141

230
24

}
}

5TT5 801-0
5TT5 801-2

1
1

1 unit
1 unit

027
027

0.141
0.142

20

230
24

}
}

5TT5 802-0
5TT5 802-2

1
1

1 unit
1 unit

027
027

0.143
0.141

400

25

230
115
24

}
B
}

5TT5 830-0
5TT5 830-1
5TT5 830-2

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.258
0.274
0.272

3 NO + 1 NC

400

25

230
115
24

}
B
B

5TT5 831-0
5TT5 831-1
5TT5 831-2

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.260
0.274
0.272

4 NO
for high capacitive
loads up to 150 F

400

25

230

5TT5 820-0

1 unit

027

0.230

2 NO + 2 NC

400

25

230
24

}
}

5TT5 832-0
5TT5 832-2

1
1

1 unit
1 unit

027
027

0.260
0.273

4 NC

400

25

230
24

}
B

5TT5 833-0
5TT5 833-2

1
1

1 unit
1 unit

027
027

0.258
0.271

4 NO

400

40

230
24

}
}

5TT5 840-0
5TT5 840-2

1
1

1 unit
1 unit

027
027

0.393
0.389

3 NO + 1 NC

400

40

230
24

B
B

5TT5 841-0
5TT5 841-2

1
1

1 unit
1 unit

027
027

0.387
0.398

2 NO + 2 NC

400

40

230
24

B
B

5TT5 842-0
5TT5 842-2

1
1

1 unit
1 unit

027
027

0.398
0.388

4 NC

400

40

230
24

}
B

5TT5 843-0
5TT5 843-2

1
1

1 unit
1 unit

027
027

0.396
0.396

4 NO

400

63

230
24

}
}

5TT5 850-0
5TT5 850-2

1
1

1 unit
1 unit

027
027

0.390
0.397

3 NO + 1 NC

400

63

230
24

}
B

5TT5 851-0
5TT5 851-2

1
1

1 unit
1 unit

027
027

0.391
0.391

2 NO + 2 NC

400

63

230
24

B
B

5TT5 852-0
5TT5 852-2

1
1

1 unit
1 unit

027
027

0.400
0.388

4 NC

400

63

230
24

}
B

5TT5 853-0
5TT5 853-2

1
1

1 unit
1 unit

027
027

0.403
0.396

0.5

}
}

5TT5 910-0
5TT5 910-1

1
1

1 unit
1 unit

027
027

0.045
0.046

1
2
3

B
B
B

5TT5 910-5
5TT5 910-6
5TT5 910-7

1 2 units
1 2 units
1 2 units

027
027
027

0.002
0.003
0.003

2 NO

230

20

230
24

1 NO + 1 NC

230

20

2 NC

230

4 NO

5TT5 830-0

5TT5 840-0

Auxiliary switches
For mounting on right-hand side
Max. one auxiliary switch per Insta contactor.
2 NO
1 NO + 1 NC

230, AC-15
230, AC-15

6
6

---

5TT5 910-0
Sealable terminal covers
For Insta contactor 20 A
For Insta contactor 25 A
For Insta contactors 40 A and 63 A

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/35

Siemens AG 2011

Switching Devices
Insta Contactors
Insta contactors, AC technology
Version

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Insta contactors with manual switch 0/I/Automatic


For alternating current continuous operation,
with switching position indication,
with AC magnetic system
}
}

5TT5 800-6
5TT5 800-8

1
1

1 unit
1 unit

027
027

0.141
0.143

B
B

5TT5 801-6
5TT5 801-8

1
1

1 unit
1 unit

027
027

0.143
0.148

}
}

5TT5 830-6
5TT5 830-8

1
1

1 unit
1 unit

027
027

0.261
0.261

}
B

5TT5 831-6
5TT5 831-8

1
1

1 unit
1 unit

027
027

0.261
0.263

}
B

5TT5 840-6
5TT5 840-8

1
1

1 unit
1 unit

027
027

0.399
0.402

230
24

B
B

5TT5 841-6
5TT5 841-8

1
1

1 unit
1 unit

027
027

0.399
0.406

230

5TT5 850-6

1 unit

027

0.394

5TT5 910-0

1 unit

027

0.045

5TT5 910-1

1 unit

027

0.046

B
B
B

5TT5 910-5
5TT5 910-6
5TT5 910-7

1 2 units
1 2 units
1 2 units

027
027
027

0.002
0.003
0.003

2 NO

230

20

230
24

1 NO + 1 NC

230

20

230
24

4 NO

400

25

230
24

3 NO + 1 NC

400

25

230
24

4 NO

400

40

230
24

3 NO + 1 NC

400

40

4 NO

400

63

5TT5 800-6

5TT5 830-6
3

5TT5 840-6
Auxiliary switches
For mounting on right-hand side
Max. one auxiliary switch per Insta contactor.
2 NO

230, AC-15

--

1 NO + 1 NC

230, AC-15

--

0.5

Sealable terminal covers


For Insta contactor 20 A
For Insta contactor 25 A
For Insta contactors 40 A and 63 A

1
2
3

* You can order this quantity or a multiple thereof.

8/36

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Soft-starting devices

Overview
The soft-starting device is an electronic control for the soft
startup of one-phase asynchronous machines. A phase control
causes the current to rise steadily. This also increases the motor
torque and the drive starts up smoothly. Because drive elements
are handled more gently they can be designed more cost-effectively. As well as a considerable reduction in startup noise, this
also helps prevent the tipping or sliding of materials to be transported. The starting current is minimized. There is no speed
adjustment. There is no marked soft start behavior without a
mechanically connected load.
If the power semiconductor is to be protected against short circuits or ground faults during startup, a super-quick fuse must be
installed. Otherwise, the usual line and motor protective measures must be used. In the case of high switching frequencies,
we recommend installing a thermistor motor protection for
monitoring the permissible motor temperature.

The soft-starting device must not be operated with capacitive


load. In order to ensure the safety of persons and systems, only
suitably qualified personnel should work on these devices.
To prevent losses in the device, the power electronics are
bridged with relay contacts after startup. Can be retrofitted in
existing plants at any time.

Benefits
On completion of startup, the power semiconductors are
bridged, which prevents overheating in the case of frequent
starting and inhibits premature wear and tear
Separate setting of ramp up time and starting torque enables
optimum adaptation to the mechanics
The LEDs for startup and continuous operation provide
constant information on the operating state.

Technical specifications
5TT3 440

5TT3 441

EN 60947-4-2

Standards
Supply/motor voltage

V AC

400

Primary operating range

Uc

0.8 ... 1.1

Rated power

VA

3.5

Rated frequency

Hz

50/60

1.4

3.5
4.6

1.7
0.7

VA
VA

5500
300

1500
100

Startup voltage

30 ... 70

20 ... 70

Starting ramp

0.1 ... 10

Recovery time

ms

100

200

Switching
cycles/h
Switching
cycles/h

36 (up to 3kW)

10

20 (from 3...5.5 kW)

10
20

Rated power dissipation Pv


Rated output of motor
- Max.
- Min.

Coil/drive
Contact1) per pole

230

At 400 V
At 400 V

Switching frequency
3 IN, TAN = 10 s, u = 20 %
3 IN, TAN = 10 s, u = 20 %
Semiconductor fuse

Super quick

35

Conductor cross-sections

Rigid
Flexible, with end sleeve

max. mm2
min. mm2

2 2.5
1 0.5

-20 ... +60

-20 ... +55

20/60/4

20/55/4

Permissible ambient temperature


Acc. to EN 60068-1

Resistance to climate
1)

For rated operational current.

Selection and ordering data


Version

Ue

Pc

Mount- DT
ing
width

V AC

MW

230

100 ... 1500 2

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Soft-starting devices
Single-phase

5TT3 441

1 unit

027

0.160

5TT3 440

1 unit

027

0.450

Soft-starting devices mounting depth 55 mm


Three-phase,
2-phase motor control

400

300 ... 5500 6

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/37

Siemens AG 2011

Switching Devices
Timers
Digital time switches

Overview

Benefits

These days, time switching is taken for granted.


In fact, it is now hard to imagine many process sequences and
energy saving processes without time switching. It could also be
argued that time switching satisfies a basic need in the electrical
installation sector.
The new generation of digital time switches have a much more
diverse range of functions than earlier devices and, thanks to
better solutions, are simpler to operate.
They can be used for switching systems or system components,
or for functions, such as: irrigation systems, greenhouses, public
gardens, swimming pools, filtering installations, canopy controls, school bells, church bells, shop window lighting, advertising lighting, gym lighting, traffic signal controls, street lighting,
illuminated signs, office lighting, lighting of stairwells and
entrances, object illumination, preheating of industrial furnaces,
spraying machines, ovens, heating systems, air-conditioning
systems, fans and ventilation systems, heating and circulation
pumps and sauna systems.

All devices have the VDE mark and are UL approved


(not 7LF4 444).

8/38

Siemens LV 10.1 2011

The menu-assisted operation with background lighting, contrast setting of the display and illuminated keys offer a clear
overview for any application
The text-assisted programming of the time switches with their
logical 4 pushbutton system and extremely intuitive menudriven handling saves time
Simple programming on the PC enables the fast creation of
complicated switching programs, thus saving time and
eliminating errors
Data keys enable the transfer of programs to the switch key,
thus saving huge amounts of time during commissioning and
maintenance
Intuitive operation of 5-way joystick
Energy saving option via astro function.

Siemens AG 2011

Switching Devices
Timers
Digital time switches

Technical specifications
Mini

Top

Profi

Astro

Expert

7LF4 401-5

7LF4 411
7LF4 412

7LF4 421
7LF4 422

7LF4 431
7LF4 432

7LF4 444

Standards

EN 60730-1, -2-7; UL 60730

EN 60730-1, -2-7

Approvals

VDE, UL 60730-1,-2-7/UL 917 CSA C22.2 No. 14 and 177

VDE

V AC
V AC/DC
Uc
Hz

110 ... 240


-0.85 ... 1.1
50 ... 60

120, 230
-0.85 ... 1.1
50 ... 60

120, 230
24
0.85 ... 1.11)
50 ... 602)

230
-0.85 ... 1.1
50 ... 60

120/230
24
80 .. 253 V1)
50 ... 602)

VA

0.035

2.5/43)

1
250
16
10

1 or 2

V AC
A
A

1 CO
>5
6000 (20 A)

1 or 2 CO
10
100000

4 CO

Supply
Rated control supply voltage Uc
- Primary operating range
- Frequency ranges
Rated power dissipation Pv
Channels/contacts
Switching channels
- Rated operational voltage Ue
- Rated operational current Ie

At p.f. = 1
At p.f. = 0.6

Contacts
- Mechanical switching cycles (in millions)
- Electrical switching cycles
At p.f. = 1
Minimum contact load
- Incandescent lamp load
- Fluorescent lamp load

At 7 F
Uncorrected

- Energy-saving lamp load

V; mA
A
VA
VA
W

12; 100
5
58
1400
100

8
60

Safety
Different phases permissible between actuator/contact

Yes

Rated impulse withstand voltage Uimp


- EMC: burst
Acc. to IEC 61000-4-4
- EMC: surge
Acc. to IEC 61000-4-5
- Electrostatic discharge
Acc. to IEC 61000-4-2

kV
kV
kV
kV

4
> 4.4
> 2.0
> 8.0

Power reserve storage


- Battery type

6/2
Li primary cell

6
Yes

Mains/battery

Program memory

Captive

--

Overvoltage category

Acc. to EN 61010-1

III

Function
Minimum switching sequences

1 min

Make and break cycles

1 min

Clock errors per day

Typical

Control input

Terminal S

s/day

+0.3 14)

1s
1s

0.86

--

Memory spaces
- Programs5)
- Pulse (alternatively)
- Pulse cycle

28
---

0.2
Yes

56 (2 28)

28 (2 14)
84
-1 s ... < 60 min --

4 3 28

Connections
Terminals screw (Pozidriv)

PZ 1

Conductor cross-sections of main current paths


- Rigid, max.
- Rigid, min.
- Flexible with end sleeve
Max.

mm2
mm2
mm2

4
1.5
2.5

Permissible ambient temperature

-10 ... +55

Storage temperature

-20 ... +60

Environmental conditions
-20 ... +55

Resistance to climate

Acc. to EN 60068-1

10/055/21

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Safety class

Acc. to EN 60730-1

II

1)

For 24 V devices (7LF4 421-2, 7LF4 422-2 and 7LF4 444-2):


Tolerance -10/+10 %; operating range 0.9 ... 1.1 Uc.

2)

For 24 V devices (7LF4 421-2, 7LF4 422-2 and 7LF4 444-2):


Frequency range 0 ... 60 Hz.

3)

For 24 V device (7LF4 444-2): Pv = 4 VA.

4)

At 25C a clock error of +0.3s is assumed. Accuracy may deviate by a


further 1s around this value.

5)

A program consists of an ON time, an OFF time and assigned ON and OFF


days or day blocks.

20/055/21

Siemens LV 10.1 2011

8/39

Siemens AG 2011

Switching Devices
Timers
Digital time switches

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Mini digital time switches


Weekly program
1 channel
1 CO

250

16

110 ... 240 1

7LF4 401-5

1 unit

027

0.156

Top digital time switches


Weekly program
With text-assisted programming concept languages:
German, English, French, Italian, Dutch, Spanish
1 channel
56 programs

1 CO

250

16

230

7LF4 411-0

1 unit

027

0.157

1 CO

250

16

120

7LF4 411-1

1 unit

027

0.159

2 channels
56 programs (28 per channel)
2 CO

250

16

230

7LF4 412-0

1 unit

027

0.182

2 CO

250

16

120

7LF4 412-1

1 unit

027

0.181

Profi digital time switches


Weekly program
With text-assisted programming concept languages:
German, English, French, Italian, Dutch, Spanish
Simple program creation by means of PC using the
software included with the 7LF4 940-0 USB adapter
Vacation program
Random program
Operating hours meter, counting range: 65535 h
1 channel
56 programs
Pulse function, 84 start times
1 CO

250

16

230

7LF4 421-0

1 unit

027

0.195

1 CO

250

16

120

7LF4 421-1

1 unit

027

0.192

1 CO

250

16

24 AC/DC 2

7LF4 421-2

1 unit

027

0.189

2 channels
56 programs (28 per channel)
2 CO

250

16

230

7LF4 422-0

1 unit

027

0.210

2 CO

250

16

120

7LF4 422-1

1 unit

027

0.209

2 CO

250

16

24 AC/DC 2

7LF4 422-2

1 unit

027

0.207

Astro digital time switches


Weekly program
Astro function
With text-assisted programming concept languages:
German, English, French, Italian, Dutch, Spanish
Simple program creation by means of PC using the
software included with the 7LF4 940-0 USB adapter
Vacation program
1 h test
Input disable over PIN code
Operating hours meter, counting range: 65535 h
1 channel
28 programs
With control input,
delay time 0 min ... 23 h 59 min
1 CO

250

16

230

7LF4 431-0

1 unit

027

0.206

230

7LF4 432-0

1 unit

027

0.221

2 channels
28 programs (14 per channel)
2 CO

250

16

* You can order this quantity or a multiple thereof.

8/40

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Timers
Digital time switches
Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Expert digital time switches

Weekly program
Year program
Exception program (priority program)
Astro function
With text-assisted programming concept languages:
German, English, French, Italian, Dutch, Spanish
Simple program creation by means of PC using the
software included with the 7LF4 940-0 USB adapter
Cycle function for channel 1
Vacation function
1 h test
Input disable over PIN code
Operating hours meter, counting range: 65535 h
84 programs per channel
With control input (only 1 channel),
delay time 0 min ... 23 h 59 min
With Expert data key, Order No. 7LF4 940-2

4 channels
4 CO

250

16

120/230

7LF4 444-0

1 unit

027

0.460

4 CO

250

16

24 AC/DC 6

7LF4 444-2

1 unit

027

0.450

7LF4 940-1

1 unit

027

0.020

7LF4 940-2

1 unit

027

0.022

7LF4 940-0

1 unit

027

0.111

7LF9 006

1 unit

027

0.070

Data keys for digital time switches: Profi and Astro


Programming at the PC
(7LF4 940-0 USB adapter and software required)
Read-in of programs to the time switch
Writing of programs from the time switch
Transfer of programs
- From PC to time switch and vice versa
- From time switch to time switch
Data keys for Expert digital time switch
Programming at the PC
(7LF4 940-0 USB adapter and software required)
Read-in of programs to the time switch
Writing of programs from the time switch
Transfer of programs
- From PC to time switch and vice versa
- From time switch to time switch
USB adapter and software for digital time switches:
Profi, Astro and Expert
For the reading and writing of data keys at the PC
With programming software
With one data key for Profi, Astro
Order No. 7FL4 940-1
Can be connected over USB interface
System requirements:
- Windows 7, Windows Vista, Windows 2000,
Windows ME, Windows XP or Windows 98
Second Edition
- USB connection
- 40 MB free disk space
Holder for front panel installation
Universal application for devices from 1 to 6 MW
Cutout dimensions:
Height 45+0.5 mm
Width 23 mm, 41 mm, 59 mm, 77 mm, 95 mm or 113 mm B

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/41

Siemens AG 2011

Switching Devices
Timers
Digital time switches

More information
Mini digital time switches
Easy commissioning:
You can get started with the programming straight away. Profi,
Astro and Expert are supplied with the time, date and automatic
daylight savings for Central Europe already set.
Clear contrast:
In order to maintain an overview even in bad light conditions and
extreme temperatures, the contrast of the display can be
adjusted - practical down to the very last detail.
Convenient programming:
It has never been so easy and uncomplicated to operate and
program a digital time switch.

The Mini digital time switch with a width of only 1 MW and its
hourly, daily and weekly program is ideal for replacement and
use in distribution boards with limited space.
The Mini digital time switch can be used flexibly as it can also be
operated in battery mode with all its functionalities. Furthermore,
the actuator of the clock can be removed from its enclosure for
easy programming over the 5-way joystick prior to mounting.
Top, Profi, Astro and Expert digital time switches
Whether you are programming locally using the text-assisted
programming, or sitting comfortably in front of your PC, the task
is quicker and easier with the Top, Profi, Astro and Expert digital
time switches.

1-channel time switches allow input of up to 56 switching programs, 2-channel time switches allow up to 28 programs per
channel and 4-channel time switches up to 84 programs per
channel. This means that the Profi, Astro and Expert time
switches are ideally equipped for even the most complex of
tasks.
Each entry required is clearly indicated so no prolonged studying of the operating instructions. And, particularly practical: you
don't even need a power supply to program the digital time
switches.
The Profi, Astro and Expert digital time switches offer more than
reliable switching. Numerous integrated convenience functions
make them versatile and simple problem solvers.
A data key enables easy programming of the Profi, Astro and
Expert digital time switches at a PC, simplifies the setting of time
switch programs and saves enormous amounts of time. This prevents human error and enables simple copying of complete time
switch programs to different time switches.
Astro function:

Simple operation:
Four programming pushbuttons offer user-friendly assistance
with a text menu.
Easy-to-read display:
And if you need to change the settings of the digital time switch
at the back of a dark control cabinet, the integral background
lighting of the display and the lighting of the control elements
offer a clear overview.

8/42

Siemens LV 10.1 2011

The Astro and Expert time switches have one key strength: the
Astro function. The exact time of sunrise and sunset is available
for every location and every day in the year. This means, for
example, that the connected outer lighting is only switched on
when it is dark - whether it is winter when the days are shorter or
in summer when the days are much longer. The benefits are
obvious:
Cost-savings, because electricity is only used when the lighting is really needed, and because this prolongs the service life
of the lighting itself. Particularly in the case of dusk-dependent
lighting controls.
Safety and convenience, because the light is always switched
on when it's dark
Ease-of-use, because the digital time switch doesn't have to
be reprogrammed throughout the year
Installation couldn't be easier, because Astro digital time
switches work in the distribution board. No further need for
laborious cable laying to the light sensors. This means that it
is not necessary to lay cables across the lightning protection
zones. The compact 2-MW series is also ideally suited for retrofitting or replacement.
It goes without saying that the digital time switches Astro and
Expert don't just switch at dawn and dusk, complex, combined
programs are also possible. You always have the choice between astronomically calculated and individually set switching
times, or a combination of both.

Siemens AG 2011

Switching Devices
Timers
Digital time switches
PC programming:

Control input:
The delay time that can be adjusted in the control input enables
an additional switching of the relay, parallel to the switching program. Settable overtravel 0 min to 23 h 59 min, the delay time
starts as soon as the voltage drops out at the control input.
1 h test:
The "1H TEST" function can be used for simulating switching. If
"1H TEST" is activated, the switching outputs are switched for
one hour. At the end of the specified time, the digital time switch
automatically resumes execution of the switching commands
according to the programmed switching times.
PIN code:
Input and programming can be disabled using a four-digit PIN
code.
Week programs:

The Profi, Astro and Expert digital time switches support plug-in
data keys. This provides even greater safety and convenience.
For example, the data key lets you read out a program from a
digital time switch, copy it to a PC, where it can be saved and
edited - or simply transfer it to another time switch. You can also
work with several data keys and it takes only a matter of seconds
to change programs.
A safety copy ensures fast service. So if a time switch has been
interfered with, you can simply use the data key to transfer the
stored program back to the time switch.
Thanks to the standard operator interface, based on MS-Office,
there is no need for laborious program training.
Pulse function for 1-channel devices:
With the pulse function, up to 84 start times and a pulse time can
be programmed onto the time switch. The pulse duration can be
selected between 1 s and 59 min 59 s.
Random function:
If the random function is activated, the set switching times are
shifted within a range of +/- 30 min.
Operating hours meter:
For commercial fields of application in particular, it is often necessary to establish the running time of the switched load, e.g.
lighting. The operating hours meter shows the total ON time per
channel and the date of the last reset.

Programs that are designed to be repeated regularly every


week, e.g. light control, heating control. A weekly program
comprises an ON/OFF time and assigned ON/OFF days.
Year programs:
Programs that are only to be executed within a defined period of
validity. They overlap with the week programs of the same channel according to an OR operation. The period of validity is specified by entering the start/end date. Validity from start date
00:00:00 to end date 24:00:00. The start date must be prior to
the end date. Within their period of validity, these programs act
as weekly programs. Outside their period of validity, these
programs have no influence on the switching behavior.
Exception programs:
have a higher priority than week and year programs. Week and
year programs of the same channel will not be executed within
the period of validity of an exception program. However, within
the period of validity other exception programs will be executed.
The different exception programs overlap according to an OR
operation.
Cycle function:
On the year time switch, channel 1 has an additional option for
"cyclic switching". The term "cyclic switching" means that within
a specific period, the time switch is switched on for a specific
duration (ON time). The cycle time can be set between 2 seconds and 2 hours. The ON time can be set between one second
and one hour.

Vacation period function:


In the vacation program, the vacation period is set with start and
end date. If the vacation program is activated, the digital time
switch does not carry out any programmed switching commands during the relative period but, depending on the respective input, is set to "CONTINUOUSLY OFF" or "CONTINUOUSLY
ON" during the vacation period. At the end of the specified
vacation period, the digital time switch automatically resumes
execution of the switching commands according to the
programmed switching times.

Siemens LV 10.1 2011

8/43

Siemens AG 2011

Switching Devices
Timers
Digital time switches
USB adapters

The Profi, Astro and Expert time switches are easy to program at
the PC using the data key with the USB adapter and software.
This enables the simple and fast creation of complicated time
switch programs. Storing and copying time switch programs is
also very easy and convenient.

Clear data on the annual ON time of the consumer enables a


precise statement on the annual power consumption.
You can create switching programs for digital time switches
easily and conveniently at the PC in the comfort of your own
home, store it on the data key and transfer it to the time switch
on site.
You save time not only when creating and transferring programs, but also during maintenance.

8/44

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Timers
Mechanical time switches

Overview
These days, time switching is taken for granted.
These days, energy savings through time switching have become a matter of course. In fact, it is now hard to imagine many
process sequences without time switching.
Mechanical time switches are used wherever the minimum
switching interval is sufficient. The switching control pins can be
set without the use of tools at minimum intervals of 15 minutes.
They can be used for switching systems or system components,
or for functions, such as: irrigation systems, greenhouses, public
gardens, swimming pools, filtering installations, canopy controls, church bells, shop window lighting, advertising lighting,
gym lighting, traffic signal controls, street lighting, illuminated
signs, office lighting, lighting of stairwells and entrances, object
illumination, preheating of industrial furnaces, spraying machines, ovens, heating systems, air-conditioning systems, fans
and ventilation systems, heating and circulation pumps and
sauna systems.

Benefits
The automatic setting system automatically sets the clock timers during commissioning. No need to manually adjust the
pointer for daylight savings.
The automatic make ready system also continues to operate
automatically after a voltage failure. No need for manual time
reset.
The precision quartz clock mechanism adds all clock errors to
approx. +/- 1 min clock accuracy per year. So there is also no
need to reset the clock timer during operation.

All devices have the VDE mark and are approved to UL.

Siemens LV 10.1 2011

8/45

Siemens AG 2011

Switching Devices
Timers
Mechanical time switches

Technical specifications
Synchronous time switches without power
reserve

Quartz-clock time switches with power reserve

7LF5
300-1

7LF5
301-1

7LF5
300-5

7LF5
300-6

7LF5
300-7

7LF5
301-0

Standards

EN 60730-1, -2-7, UL 917

Approvals

UL 60730-1,-2-7/UL 917 CSA C22.2 No. 14 and 177

Operating mode

Synchronous

Time program

Day

Day

7LF5
301-4

7LF5
301-5

7LF5
301-6

7LF5
301-7

7LF5
305-0

Day

Week

Day

Week

Day

0.2

0.2

1 CO

1 CO

1 CO

1 CO

1 CO

Quartz
Week

Hour

Day

Day

Supply
Rated control supply voltage Uc
- Primary operating range

V AC 230
Uc 0.85 ... 1.1

230
0.85 ... 1.1

Rated frequency
- Frequency ranges

Hz
Hz

50
50

50
50/60

Rated power dissipation Pv

VA

Channels/contacts

Switching channels
- Rated operational voltage Ue
- Rated operational current Ie
At p.f. = 1
At p.f. = 0.6

1
V AC 250

1
250

A
A

16
4

Contacts
- Mechanical switching cycles
in millions
- Electrical switching cycles at p.f. = 1

16
4
1 NO
20
100000

1 CO

1 CO

1 NO

1 CO

1 NO
20
100000

V; mA 4; 1
5
A

4; 1
5

VA
VA

60
1400

60
1400

Different phases permissible


between actuator/contact

Yes

Yes

Electrical isolation, creepage distances


and clearances, actuator/contact
mm

8/6

8/6

Minimum contact load


- Incandescent lamp load
- Fluorescent lamps
At 7 A
Uncorrected
Safety

Rated impulse withstand voltage Uimp kV


drive/contact
kV
- EMC: burst acc. to IEC 61000-4-4

> 4.4

> 4.4

- EMC: surge acc. to IEC 61000-4-5

kV

> 2.0

> 2.0

- Electrostatic discharge acc. to


IEC 61000-4-2

kV

> 8.0

> 8.0

a
h

----

100 h
48
NiMH
cell

6
-Li primary cell

100 h
48
NiMH cell

a
a

---

6
5

10

III

III

Power reserve storage


- Minimum loading time
- Battery type
- Service life of battery
At 20 C
At 40 C
Overvoltage category acc. to
EN 61010-1
Function
Minimum switching sequences

min

30

240

30

30

240

30

240

30

Make and break cycles

min

15

120

37.5 s

10

15

120

15

120

10

Switching accuracy

min

30

0.2

30

30

System-synchronized

2.5 s

Terminals screw (Pozidriv)

PZ 1

PZ 1

Conductor cross-sections of main current


paths
- Rigid, max.
mm2
- Rigid, min.
mm2
- Flexible, with end sleeve
mm2
- Flexible, without end sleeve
mm2

4
1.5
2.5
4

4
1.5
2.5
4

Clock errors per day

60/year

2.5 s

Connections

Environmental conditions
Permissible ambient temperature

-10 ... +55

-10 ... +55

Storage temperature

-10 ... +60

-10 ... +60

Resistance to climate acc. to EN 60068-1

10/055/21

10/055/21

Degree of protection acc. to EN 60529

IP20, with connected conductors

IP20, with connected conductors

Safety class acc. to EN 61140

II

II

8/46

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Timers
Mechanical time switches

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Synchronous time switches without power


reserve, 1 MW
Day disk
1 NO

250

16

230

7LF5 300-1

1 unit

027

0.083

250

16

230

7LF5 300-7

1 unit

027

0.083

Hour disk
1 NO

Synchronous time switches without power reserve,


3 MW
Day disk
1 CO

250

16

230

7LF5 300-5

1 unit

027

0.151

250

16

230

7LF5 300-6

1 unit

027

0.153

--

7LF5 301-0

1 unit

027

0.196

7LF5 301-1

1 unit

027

0.088

Week disk
1 CO

Synchronous time switches without power reserve,


for wall mounting
Day disk
1 CO

250

16

230

Quartz-clock time switches with power reserve


Day disk
1 NO

250

16

230

Quartz-clock time switches with power reserve


and automatic time setting
for Central European time zone

Time set automatically during commissioning


Automatic daylight savings
With quartz clock mechanism
clock accuracy 0.2 s/day
5-year power reserve
(time buffer in the event of a voltage failure)

Day disk
1 CO

250

16

230

7LF5 301-4

1 unit

027

0.182

250

16

230

7LF5 301-5

1 unit

027

0.179

Week disk
1 CO

Quartz-clock time switches with power reserve


Clock accuracy 2.5 s/day
Day disk
1 CO

250

16

230

7LF5 301-6

1 unit

027

0.157

250

16

230

7LF5 301-7

1 unit

027

0.158

--

7LF5 305-0

1 unit

027

0.205

Week disk
1 CO

Quartz-clock time switches with power reserve,


for wall mounting (surface mounting)
Day disk
1 CO

250

16

230

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/47

Siemens AG 2011

Switching Devices
Timers
Mechanical time switches
Version

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Holder for front panel installation


Universal application for devices from 1 to 6 MW
Cutout dimensions:
Height 45+0.5 mm
Width 23 mm, 41 mm, 59 mm, 77 mm, 95 mm or
113 mm

7LF9 006

1 unit

027

0.070

More information

Mechanical time switches with day disk

Mechanical time switches with week disk

Synchronous time switches without power reserve

LED display

The control gear is driven by a synchronous motor so it is dependent on the power supply frequency. If this frequency is unstable, the devices cannot be used. In the event of a power failure,
the time switch will stop.

The adjustment data for Central Europe are stored and an LED
provides information on the current state.

Quartz-clock time switches with power reserve


A quartz electronic circuit supplies the drive with a stabilized frequency so that the time switch is not dependent on the power
supply frequency. In the event of a power failure, the time switch
continues to operate on its power reserve.
Automatic setting system

So: simply unpack, snap into place, connect and set the desired
switching times - no tools required! This saves time and money.
Clear design
Extremely intuitive thanks to clear design. The switching times
are easy to read.
With the weekly time switch, the make and break cycles are only
120 minutes with a minimum switching interval of 240 minutes.

This supports fast and easy installation of the 7LF5 301-4 and
7LF5 301-5 time switches. These time switches self-adjust during commissioning in fast mode to the correct time and correct
day within the Central European zone. They also automatically
set the correct time for daylight saving. A further advantage is
the quartz-precise adjustment of the correct time and the correct
day as soon as the supply voltage is reconnected after a power
failure.
Precision quartz mechanism
Clock accuracy: The internal precision clockwork has an accuracy of 1 min. per year. Until now, this level of accuracy and automatic operational safety was only possible using digital time
switches.
Optimization of power consumption due to minimum make and
break cycles of 15 minutes: it is possible to set the switching
times in 15-minute patterns, with a switching interval of at least
30 minutes.

* You can order this quantity or a multiple thereof.

8/48

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Timers
Timers for buildings

Overview

Benefits

In many installations there is great savings potential to be found


in the lighting of corridors, stairwells and ancillary rooms. Many
installations are in operation for hours without anyone being
present. Lighting which is switched on unnecessarily in ancillary
rooms often goes unnoticed for days.
Due to the gradual phasing out of incandescent lamps starting
in September 2009, it is crucial we switch to other types of lighting. In particular compact fluorescent lamps (energy-saving
lamps such as the Osram Dulux EL) will be used more frequently
in stairwells as in other areas.

Energy savings through disconnection of unnecessary equipment


Reliable durable switching of different illuminants using patented contact design
Suitable for energy-saving lamps
Ultra-quiet stairwell lighting timers - ideal for residential areas
Warning of impending switch-off according to DIN 18015-2 for
stairwell lighting in apartment houses.

Our stairwell lighting timers offer different levels of convenience,


depending on the range of functions. On stairwell lighting timers
from Siemens, the required time can be precisely set without
tools using the push-to-lock knurling wheel. With modern fourwire installations, stairwell lighting timers can always just be
pressed again. A maintained light switch prevents the need for
repeated pressing, for example when moving house. The various types are available either with or without warning prior to
switch-off.

Technical specifications
7LF6 110 7LF6 111 7LF6 113 5TT1 303 7LF6 114 7LF6 115 7LF6 116 7LF6 112
IEC 60669, EN 60669

Standards
Supply
Rated control supply voltage Uc
- Primary operating range

At 50/60 Hz

V AC
Uc

230
0.9 ... 1.1

Rated power dissipation Pv

VA

Approx. 5

Setting range

min

0.5 ... 10

Accuracy

30

Manual switches

Automatic/permanent

Voltage endurance

0.5 ... 10 3 ... 60

--

700

10

16

0.3

>3

0.5 ... 10

Yes
ms

Minimum push duration

1 ... 10

At pushbutton input
(pushbutton malfunction)

30
Yes

700

V AC
A

250
16

Contact gap

mm

>3

Minimum contact load

V; mA

10; 300

Max. incandescent lamp load

2000

--

2000

--

Max. energy-saving lamp load 14 W

Unit(s)

20

--

20

--

Unit(s)
Unit(s)
Unit(s)
Unit(s)

20
2 20
10
25

--6
3

20
2 20
10
25

Glow lamp load

mA

50

10

50

Max. fan load

VA

--

Short-circuit strength
Channels/contacts
Switching channels
- Rated operational voltage Ue
- Rated operational current Ie

Fluorescent lamp load 58 W


- Uncorrected
- DUO circuit
- Siemens ECG

At p.f. = 1

1 lamp
2 lamps

--

-200

Connections
Terminals screw (Pozidriv)

PZ 1

Conductor cross-sections of main current paths


- Rigid
- Flexible, with end sleeve
Min.

mm2
mm2

1.5 ... 6
1

-20 ... +50

Environmental conditions
Resistance to climate

Acc. to EN 60068-1

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Siemens LV 10.1 2011

8/49

Siemens AG 2011

Switching Devices
Timers
Timers for buildings

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Stairway lighting timers


With switch for continuous light and latch setting,
setting range 0.5 ... 10 minutes
For 3-wire circuit, L-momentary contact,
not resettable
250

16

230

7LF6 110

1 unit

027

0.080

7LF6 111

1 unit

027

0.088

7LF6 113

1 unit

027

0.088

7LF6 114

1 unit

027

0.088

7LF6 116

1 unit

027

0.071

7LF6 115

1 unit

027

0.088

7LF6 112

1 unit

027

0.082

5TT1 303

1 unit

027

0.143

For 4-wire circuit, L-momentary contact, resettable,


or 3-wire circuit, N-momentary contact, resettable
250

16

230

With warning by flashing prior to switching off,


for 4-wire circuit, L-momentary contact, resettable,
or 3-wire circuit, N-momentary contact, resettable
250

16

230

Lighting timers
With switch for continuous light and push-to-lock knurling wheel setting,
with warning by flashing prior to switch-off, setting range
0.5 ... 10 minutes,
4-fold extension of runtime by pressing the pushbutton
for 1 second,
for 4-wire circuit, L-momentary contact,
or 3-wire circuit, N-momentary contact
250

16

230

Energy-saving timers
With switches for continuous light and push-to-lock
knurling wheel setting,
setting range 3 ... 60 minutes,
switch off by pressing pushbutton a second time briefly
(< 1 s) as with remote control switch, reset by pressing
pushbutton a second time for longer (> 1 s),
for 4-wire circuit, L-momentary contact, resettable,
or 3-wire circuit, N-momentary contact, resettable
250

16

230

With switch for continuous light and push-to-lock knurling wheel setting,
with warning by flashing prior to switch-off, setting range
3 ... 60 minutes,
switch off by pressing pushbutton second time as with
remote control switch,
for 4-wire circuit, L-momentary contact, resettable,
or 3-wire circuit, N-momentary contact, resettable
250

16

230

Timers for fans up to 200 VA


With switch for continuous operation and push-to-lock
knurling wheel setting,
setting range 0.5 ... 10 minutes,
for delayed switch-on of fan
250

16

230

ECG control switch for ECG 1 ... 10 V


With transparent cap, with switch for continuous light
and position indication, range 1 ... 10 minutes,
with warning of switching off through dimming,
direct voltage output 1 ... 10 V for controlling 20 ECG
250

10

230

* You can order this quantity or a multiple thereof.

8/50

Siemens LV 10.1 2011

Siemens AG 2011

Switching Devices
Timers
Timers for industrial applications

Overview

Benefits
Suitable for universal use because the devices can be operated with 12 - 240 V AC/DC and work across a broad range
from seconds to hours
An off-delay without auxiliary power supports expanded
application.

Time relays are primarily used in series applications where the


use of PLC controls is too labor and cost-intensive. Multifunction
relays are now the market standard. Operation is clear, simple
and offers a range of functions.

Technical specifications
5TT3 185

5TT3 181
5TT3 182
5TT3 183

5TT3 184

110 ... 240


110 ... 240

EN 60255; EN 61810

Standards
Supply
Rated control supply voltage Uc

V AC
V DC
Uc

12 ... 240
12 ... 240
0.8 ... 1.1

220 ... 240


--

Rated frequency fn

Hz

45 ... 400

50/60

Rated power dissipation Pv

VA

Approx. 1.5

Approx. 5

- Primary operating range

Approx. 1

See setting ranges, timing intervals

Setting ranges
ms

15 ... 80

Approx. 40

Approx. 100

Switching channels
- Rated operational voltage Ue
- Rated operational current Ie

V AC
A

250
4

Contact gap
- Minimum contact load

mm
V; mA

 contact
10; 300
-1.5 105

1.5 105
--

Recovery time

Contacts

Rated impulse withstand voltage Uimp

Input/output

kV

>4

Electrical service life

In switching cycles
At AC-15

1A

1.5 105
--

Connections
Terminals screw (Pozidriv)

Conductor cross-sections of main current


paths
- Rigid, max.
- Flexible, with end sleeve, min.

mm2
mm2

2 2.5
2 1.5

-40 ... +60

Environmental conditions
Permissible ambient temperature
Resistance to climate

40/60/4

Acc. to EN 60068-1

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Multifunction timers
Programmable for:
response delay; passing make contact function;
delayed pulse generator; clock generator starting
with impulse; off-delay; pulse converter; passing
break contact function; response/off-delay
1 CO

250

DC 12 ... 240
AC 12 ... 240

5TT3 185

1 unit

027

0.085

220 ... 240 AC 1

5TT3 181

1 unit

027

0.090

220 ... 240 AC 1

5TT3 182

1 unit

027

0.079

220 ... 240 AC 1

5TT3 183

1 unit

027

0.084

110 ... 240 AC 1


110 ... 240 DC

5TT3 184

1 unit

027

0.077

Delay timers
1 CO

250

Wiper timers
1 CO

250

Flashing timers
Pulse time is equal to idle time
1 CO

250

Off-delay timers
1 CO

250

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

8/51

Siemens AG 2011

Switching Devices
Timers
Timers for industrial applications

More information
5TT3 185 multifunctional timers

Time operation interruption/time addition

Setting aids

For the functions AV, EW, IE, BI, the timing interval can be interrupted at any time by activating B1 (+) and by removing the control voltage continued again (time addition).

The period of the flashing of the green LED 1 when set for a timing interval is 1 s 4%, which can therefore be used as a setting
aid. This is particularly useful in the lower time setting range and
for long delay times because the multiplication factors between
the individual time ranges are exact.
Example:
Delay time to be set: 40 min.
Using the fine setting, this delay time can be set within the setting range 3 ... 300 min. However, in this case it takes a long time
to check the time and requires several operational sequences in
realtime. To speed up the setting process, the setting range will
be switched to 0.03 ... 3 min. In this case, the required value corresponds to a delay time 0.4 min (= 24 s). The timing interval is
triggered and the potentiometer is set to 24 flashing periods of
the yellow LED 2. The device is then set back to the setting
range 3 ... 300 min and the setting process is completed.

The functions RV, IF, AW, AV/RV can be controlled using the control input B1 (+) with potential against terminal A2. The auxiliary
voltage of terminal A1 can be used for this purpose, as well as
any other voltage within the range 12 ... 240 V AC/DC. The operation of parallel loads (e.g. contactors) from B1 (+) to A2 is also
permissible.
If voltage is simultaneously applied to the control input B1 (+)
and A1 for the IF function, this triggers an output pulse with the
set time interval t1.

Possible time setting ranges t:

Position Contact
Function
c
switch

Control S1

0.02
0.06
0.3
0.03
0.3
3
0.3
3

A1-A2
St

B1-A2

Response delay

AV

Passing make contact


function

EW

Pulse generator, delayed IE

Flashing relay,
starting with impulse

BI

15-18
15-16
15-18
15-16

1
6
30
3
30
300
30
300

s
s
s
min
min
min
h
h

15-18
15-16
15-18
15-16

Control S2

...
...
...
...
...
...
...
...

0,5 s

t
t

t
A1 15
16 18

A1-A2
LED 1 green

B1-A2
OFF-delay

RV

Pulse shape

IF

Passing break contact


function

AW

AV/RV

Response delay
OFF-delay
Control S1

L+

E1
LED 2 yellow

15-18
15-16

15-18
15-16
15-18
15-16
15-18
15-16

t
t

L+
S2

A2

B1(+) A1

Contact S1
For the functions: response delay,
passing make contact function,
pulse generator delayed,
clock generator (start with pulse)
the timing interval is triggered by
closing the switching contact S1.

8/52

Siemens LV 10.1 2011

t
t

User interfaces

S1
A1

E2

t
B1(+) A2

I2_10908b

Control S2

A2

Control contact S2
The functions: off-delay,
pulse shape, passing break contact
function, response and off-delay are
triggered by continuous power
supply over the control contact S2
between A1 and B1 (+).

LED 1
LED 2
E1
Z
E2

I201_11970

Control input B1

Front view

Status display
LED 1 green: status display
Switching position indication
LED 2 yellow: switching
Setting range adjuster
position
Fine adjuster for setting ranges
indication
Function settings for timing intervals E1: Setting range adjuster
Z: Fine adjuster for
Device displays
setting ranges
LED 1 Lights up if operational voltage
E2: Function settings for
is applied (green)
timing intervals
LED 2 indicates the timing interval and state
of the equalizing relay (yellow)
Continuous light
- Off output relay not activated,
no timing interval
- On output relay not activated,
no timing interval
Flashing light
- Short on, long off
Output relay not activated, timing interval
- Short on, long off
Output relay activated, timing interval

Siemens AG 2011

Transformers, Bells and


Socket Outlets
9/2

Introduction

9/3

Bell Transformers

9/5

Transformers for Permanent Loads

9/7

Power Supply Units

9/9

Bells and Buzzers

9/10

REG Socket Outlets


Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/
configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Transformers, Bells and Socket Outlets


Introduction

Page

Field of application

Non-residential
buildings

Residential
buildings

Industry

Overview
Devices

Standards

Used in

Bell transformers

9/3

Power supply up to 40 VA as safety extraEN 61558-2-8


low voltage (SELV) in residential buildings
for the supply of gongs, buzzers, bells, door
openers and remote control switches

--

Transformers for permanent


loads

9/5

Power supply up to 63 VA as safety extralow voltage (SELV) for the supply of control
circuits, switching relays and Insta contactors

EN 61558-2-2

--

Power supply units

9/7

Direct voltage power supply up to 24 V DC EN 61558-2-6


and 2 A as safety extra-low voltage (SELV)
for the supply of gongs, buzzers, bells, door
openers, switching relays and Insta contactors

Bells and buzzers

9/9

Bells and buzzers serve to indicate alarm


states or for general acoustic signaling.
They are used as modular installation
devices in distribution boards.

REG socket outlets

9/10

For power supply during maintenance in


distribution boards in DIN VDE, CEE 7,
CEI 23-50 and UL 489 versions

DIN VDE 0620-1,

CEE 7 standard sheet V,


CEI 23-50,
UL 498

9/2

Siemens LV 10.1 2011

Siemens AG 2011

Transformers, Bells and Socket Outlets


Bell transformers

Overview

Benefits

A typical application for these bell transformers is short-time


use, as occurs with bells, gongs, door openers or remote control
switches in residential buildings.
The standard EN 61558 distinguishes between transformers for
short-time loading and those for permanent loading. This means
that clear requirements for bell transformers are defined. Bell
transformers must maintain 100 % of their rated power for
1 minute, or 20 % for 5 minutes, without tripping.

Bell transformers with a footprint of only one modular width


Reliable device protection through PTC resistors; for protection against overload and short-circuits
The bell transformers are IMQ (Italy) and VDE approved. This
ensures operational safety.

Siemens bell transformers are protected against short circuit or


moderate overload by a PTC resistor. If a disconnection occurs,
the bell transformer must be switched off for approx. 30 minutes
to cool down the PTC resistor.

Technical specifications
4AC3 006

4AC3 008

4AC3 016

4AC3 108

4AC3 116

4AC3 140

16

16

40

EN 61558-2-8
EN 61558-2, IMQ

Standards
Approvals
Rated operational power Ps

VA

Rated operational voltage Ue

V AC 230

Operating range at 50/60 Hz

Ue

0.9 ... 1.06

Rated frequency

Hz

50

Operating frequency range

Hz

45 ... 65

Rated secondary voltage Usec


In series connection

V AC 12
V AC --

24
8

Rated secondary current Isec


At 4 V
At 8 V
At 12 V
At 24 V

A AC -A AC -A AC 0.67
--

2 1.0
1
---

2 2.0
1
---

--2 0.33
0.33

--2 0.67
0.67

--2 1.67
1.67

Rated power dissipation PV


In no-load operation
At rated load

W
W

0.78
1.65

1.8
5

2.4
7.5

1.6
3.6

1.6
8.2

1.2
17.2

Safe separation
Creepage distances and clearances

mm

>3

2 12
24

Insulation class
Test voltage, 50 Hz, 1 minute
Primary against secondary winding
Terminals

48 ... 62

kV
screw (Pozidriv)

> 3.75

Conductor cross-sections
Rigid
Flexible, with end sleeve

mm2
mm2

1 6 or 2 4
0.75

Permissible ambient temperature

-10 .... +25

Permissible humidity

 80

Degree of protection

Acc. to EN 60629

IP20

Safety class

Acc. to EN 61140/
VDE 0140-1

II

Siemens LV 10.1 2011

9/3

Siemens AG 2011

Transformers, Bells and Socket Outlets


Bell transformers

Selection and ordering data


Ue

Uc

Isec

Ps

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

V AC

A AC

VA

MW

0.67

4AC3 006

1 unit

027

0.189

kg

Bell transformers
With PTC protection
230

12

With two secondary voltages, optionally for


series or parallel switching
230

2 4/8

2 1/1
2 2/2

8
16

2
2

A
B

4AC3 008
4AC3 016

1
1

1 unit
1 unit

027
027

0.273
0.351

2 12/24

2 0.33/0.33
2 0.67/0.67
2 1.67/1.67

8
16
40

2
2
3

}
A
A

4AC3 108
4AC3 116
4AC3 140

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.269
0.347
0.570

* You can order this quantity or a multiple thereof.

9/4

Siemens LV 10.1 2011

Siemens AG 2011

Transformers, Bells and Socket Outlets


Transformers for permanent loads

Overview

Benefits
The transformers with 24 VA, 40 VA and 63 VA cores are
molded, which means that they are hum-free and suitable for
installation in sound-sensitive distribution boards
Reliable device protection through PTC; provide longstanding
protection against overload and short circuits
The transformers are IMQ and VDE approved this ensures
operational safety.

These transformers up to 63 VA provide a safety extra-low voltage for supplying control current circuits, switching relays or
Insta contactors in continuous operation as alternating voltage
power supply for 8 V, 12 V or 24 V AC.
Siemens transformers for permanent loading are protected
against short circuit or moderate overload by a PTC resistor. If a
disconnection occurs, the transformer must be switched off for
approx. 30 min to allow the PTC resistor to cool down.
EN 61558-2-2 specifies that with transformers for permanent
loading the difference between the non-loaded output voltage
and the output voltage loaded with the rated load must not exceed 10 %. This requirement places the highest demands on the
design of this type of transformer. It can only be met by using
high-quality core materials and a core design with an extraordinarily high efficiency, such as type EI to DIN 41302.

Technical specifications
4AC3 408 4AC3 516 4AC3 524 4AC3 540 4AC3 616 4AC3 624 4AC3 640 4AC3 663
EN 61558-2-2
EN 61558-2, IMQ

Standards
Approvals
Rated operational power Ps

VA

16

24

40

16

24

40

63

Rated short-time power


p.f. = 0.5; t = 10 s

VA

10

18

27

48

18

27

48

80

Rated operational voltage Ue

V AC

230

Operating range at 50/60 Hz

Ue

0.9 ... 1.1

Rated frequency

Hz

50

Operating frequency range

Hz

48 ... 62

Rated secondary voltage Usec


In series connection

V AC
V AC

8
No

24
8

8
No

Rated secondary current Isec


At 4 V
At 8 V
At 12 V
At 24 V

A AC
A AC
A AC
A AC

No
1
No
No

22
2

No
3

No
2 0.67
0.67

21
1

2 1.67
1.67

2 2.62
2.62

Rated power dissipation PV


In no-load operation
At rated load

VA
W

3.5
2.6

10.3
4.6

8.0
3.6

13.1
6.3

8.3
5.7

23.0
10.0

No

Yes

Hum-free Core molded

No

Safe separation
Creepage distances and clearances

mm

Yes

2 12
24

13.8
6.9

3
B

Insulation class
Test voltage, 50 Hz, 1 minute
Primary against secondary winding
Terminals

8.0
2.7

kV

screw (Pozidriv)

Conductor cross-sections
Rigid
Flexible, with end sleeve, min.

4
1

mm2
mm2

1 ... 6
0.75

Permissible ambient temperature


In operation

-10 ... +40

Permissible humidity

 80

Degree of protection

Acc. to EN 60529

IP20

Safety class

Acc. to
EN 61140/VDE 0140-1

II

Siemens LV 10.1 2011

9/5

Siemens AG 2011

Transformers, Bells and Socket Outlets


Transformers for permanent loads

Selection and ordering data


Ue

Usec

Isec

Ps

Mount- DT
ing
width

V AC

V AC

A AC

VA

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Transformers for permanent loads


With PTC protection for AC voltage/current supply as
safety extra-low voltage
For continuous operation for the supply of control circuits,
switching relays and Insta contactors
With one secondary voltage
230
8
1
3
5

8
24
40

3
4
4

A
B
B

4AC3 408
4AC3 524
4AC3 540

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.513
0.827
0.802

With two secondary voltages, optionally for


series or parallel switching
230

2 4/8

2 2/2

16

4AC3 516

1 unit

027

0.560

2 12/24

2 0.67/0.67
2 1.0/1.0
2 1.67/1.67
2 2.62/2.62

16
24
40
63

3
4
4
5

A
A
A
A

4AC3 616
4AC3 624
4AC3 640
4AC3 663

1
1
1
1

1 unit
1 unit
1 unit
1 unit

027
027
027
027

0.563
0.873
0.811
1.096

* You can order this quantity or a multiple thereof.

9/6

Siemens LV 10.1 2011

Siemens AG 2011

Transformers, Bells and Socket Outlets


Power supply units

Overview

Benefits

The electronic power supply unit provides a 24 V DC supply to


systems with an operational voltage of 85 to 265 V AC or
85 to 300 V DC. The device operates in the lower class for
minimum power supply with a safety extra-low voltage (SELV).
In the event of short circuits and high capacitive loads, the
power supply unit detects the overcurrent as soon as it is activated and shuts down immediately. It switches back on after
2.5 seconds. The electronic power supply unit is suitable for
supplying the 5TT7 1 GSM alarm modules within a supply
voltage range of 150 to 230 V AC.
Power supply units for direct voltages with rectifiers are used to
supply gongs, bells, door openers, switching relays, remote
control switches, Insta contactors or for safety extra-low voltage
systems (SELV) in continuous operation. They are protected
against short circuit or moderate overload by a PTC resistor. If
tripped, the power supply unit must be switched off for approx.
30 mins. to allow the PTC resistor time to cool down.

Expanded applications due to safety extra-low voltage SELV.


Electronic power supply units
Smallest electronic power supply unit in the lower power class
in 2 MW. This saves valuable space in distribution boards
Universal applications in many systems, thanks to wide range
voltage supply of 85 V to 265 V AC or 85 V to 300 V DC
Interference suppression to limit value Class B (lower limit)
even meets the requirements for residential buildings.
Power supply units with bridge rectifiers
The power supply units are IMQ and VDE approved. This
ensures continuous operation.

Technical specifications
4AC2 400

4AC2 401

EN 61558-2-6

Standards

EN 60068-2,
EN 61558-1,
EN 61000-4

EN 61558-2; IMQ

Approvals
Rated operational power Ps

24

Rated operational voltage Ue

V AC
V DC

230
--

Permissible operational voltage


For the 5TT7 1 GSM alarm modules

4AC2 402

-43

85 ... 265
85 ... 300

V AC/DC --

150 ... 265

Ue

0.9 ... 1.1

--

Rated frequency

Hz

50

50/60

Operating frequency range

Hz

48 ... 52

Rated secondary voltage Usec

V DC

12

24

24 5 %

Rated secondary current Isec

A DC

2.0

1.8

0.35

Primary operating range

At 50/60 Hz

Residual ripple
Rated power dissipation Pv

In no-load operation
At rated load

Hum-free

Core molded

Safe separation

Creepage distances and


clearances

mV

--

W
W

5
10

50 Hz, 1 min

Insulation resistance

Electronic overload
protection
< 100
6
15

---

Yes

--

> 5.5

--

kV

>4

--

kV

--

--

6 kV/2

mm

Insulation class
Test voltage
Primary against secondary winding

--

PTC

Current limitation

Rated impulse withstand voltage/


degree of pollution

Acc. to IEC 60664-1

Static discharge

Acc. to IEC/EN 61000-4-2

kV

--

RF irradiation

Acc. to IEC/EN 61000-4-3

V/m

--

10

Transient overvoltage (burst)

Acc. to IEC/EN 61000-4-4

kV

--

Transient overvoltage (surge)


Supply lines A1, A2
A1/A2 and ground

Acc. to IEC/EN 61000-4-5


kV
kV

---

1
2

RF, conducted disturbance

Acc. to IEC/EN 61000-4-6

--

10

Interference suppression to lower limit class Acc. to EN 61000-6-3

--

Complied with

Terminals
Screw (slotted-head)
screw (Pozidriv)

-1

M2.5
--

Conductor cross-sections
Rigid
Flexible, with end sleeve, min.

mm2
mm2

1.5 ... 6
0.75

0.5 ... 2.5


0.5 ... 1.5

Permissible ambient temperature

-10 ... +40

-20 ... +60

Permissible humidity

 80

Resistance to climate

Acc. to IEC/EN 60068-1

Resistance to vibrations
Frequency 10 ... 55 Hz

Acc. to IEC/EN 60068-2-6

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Safety class

Acc. to EN 61140

II

mm

8.4

--

20/045/04

--

0.35 amplitude

Siemens LV 10.1 2011

9/7

Siemens AG 2011

Transformers, Bells and Socket Outlets


Power supply units

Selection and ordering data


Ue

V AC

V DC

Usec

Isec

Ps

Mount- DT
ing
width

V DC

A DC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Power supply units


With transformer for safety extra-low voltage,
with rectifier in center tap connection
230

--

12

2.0

24

4AC2 400

1 unit

027

0.840

--

24

1.8

43

4AC2 401

1 unit

027

1.106

0.35

8.4

4AC2 402

1 unit

027

0.081

Electronic power supply unit


SELV, short-circuit resistant
85 ... 265

85 ... 300

24 5 %

* You can order this quantity or a multiple thereof.

9/8

Siemens LV 10.1 2011

Siemens AG 2011

Transformers, Bells and Socket Outlets


Bells and buzzers

Overview

Benefits
Bell transformers and buzzers with a footprint of only one
modular width
Reliable device protection through PTC; for protection against
overload and short circuits.

Bells and buzzers are typically used in residential buildings and


non-residential buildings, such as shops, offices, banks, etc.
They are used to indicate alarm states or for general acoustic
signaling.
Bells and buzzers are used as modular installation devices in
distribution boards. These devices are designed for short-time
use in compliance with IEC 62080.

Technical specifications
7LQ2 204-0
7LQ2 205-0
7LQ2 206-0

7LQ2 204-1
7LQ2 205-1
7LQ2 206-1

IEC 62080

Standards
Rated operational power Ps

VA

5.5

Rated operational voltage Ue

V AC

230

12

Ue

0.94 ... 1.06

Rated frequency

Hz

50

Operating frequency range

Hz

45 ... 65

0.83

At 50/60 Hz

Primary operating range

Rated power dissipation PV

In no-load operation

Pollution degree

Acc. to EN 61010-1

Working voltage

Acc. to EN 61010-1

Insulating material group

Acc. to EN 61010-1

2
V AC

230

12

II

Safe separation
Clearance
Creepage distances in device

mm
mm

3
 2.5

 1.5
 1.5

Test voltage, 50 Hz, 1 min

kV

1.25

Flammability

Class

V0

Conductor cross-sections
Rigid
Flexible with end sleeve

mm2
mm2

1 6 or 2 4
0.75

Volume

dB

 75

Permissible ambient temperature

-10 ... +55

Permissible humidity

 80

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Safety class

Acc. to EN 61140

II

Selection and ordering data


Ue

Ps

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

VA

MW

230
12

5.5
4

1
1

B
B

7LQ2 204-0
7LQ2 204-1

1
1

1 unit
1 unit

027
027

0.072
0.086

230
12

5.5
4

1
1

B
B

7LQ2 205-0
7LQ2 205-1

1
1

1 unit
1 unit

027
027

0.073
0.070

230
12

5.5
4

1
1

B
B

7LQ2 206-0
7LQ2 206-1

1
1

1 unit
1 unit

027
027

0.053
0.103

kg

Bells

Buzzers

Bell-buzzer combinations

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

9/9

Siemens AG 2011

Transformers, Bells and Socket Outlets


REG socket outlets

Overview
The socket outlets for mounting in distribution boards to
DIN 43880 and on TH35 standard mounting rails to DIN 60715
have since become standard in modern switchgear/distribution
boards. They are used for tasks such as the connection of plugin communication devices in communication distribution boards,
in switchgear assemblies for maintenance purposes or in private
plants for the occasional use of devices with heavy starting and
separate fusing.
The socket outlet range complies with a number of different standards and is available according to the standards of the following countries: VDE for Germany, CEE7 for Belgium/France,
CEI for Italy and UL for USA.

In distribution boards with 55 mm mounting depth the socket


outlet can only be used without the hinged lid. The lids can be
retrofitted on all devices. To make installation easier, the touchprotected terminals L, N and PE are located on the side of the
socket outlet.
In plant sections where equipment is still live, even after the main
switch has been disconnected, this must be indicated according to EN 50110-1 and IEC/EN 60204-1. Yellow socket outlets are
used for these applications.

Benefits
Complete program according to VDE, UL, CEI and CEE for
worldwide application.

By pulling on the hinges, the hinged lid stays open > 180.
This facilitates manual insertion of connectors.

Technical specifications

5TE6 800

5TE6 801

5TE6 810

5TE6 802

5TE6 803

5TE6 804

Standards

VDE 0620-1

VDE 0620-1

VDE 0620-1

CEI 23-50

CEE 7 standard sheet V

UL 498

Approvals

VDE 0620-1

--

UL File No.
E258598/
CSA C22.2
No. 182.3M

Rated operational voltage Ue

V AC

230

125

Rated operational current Ie

A AC

16

15

Terminals screw (Pozidriv)

PZ1

Terminal tightening torque, max.

1.2

Stripped length

mm

10

Conductor cross-sections
Rigid
Flexible, with end sleeve
Rigid
Flexible

mm2
mm2
AWG
AWG

1.5 ... 6
0.5 ... 4
10 ... 14
14

Permissible ambient temperature

-10 ... +55

Degree of protection
Acc. to EN 60529

IP20, with connected conductors

Mounting position

Without cover: any, with cover: vertical or horizontal

Selection and ordering data


Ue

Ie

Conductor Mount- DT
crossing
section
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

mm2

MW

2.5

5TE6 800

1 unit

027

0.086

2.5

5TE6 801

1 unit

027

0.093

kg

SCHUKO socket outlets


according to DIN VDE 0620-1
Without hinged lid
230

16

SCHUKO socket outlets


according to DIN VDE 0620-1
With hinged lid
230

16

* You can order this quantity or a multiple thereof.

9/10

Siemens LV 10.1 2011

Siemens AG 2011

Transformers, Bells and Socket Outlets


REG socket outlets
Ue

Ie

Conductor Mount- DT
crossing
section
width

V AC

mm2

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

MW

Weight
per PU
approx.
kg

SCHUKO socket outlets


according to DIN VDE 0620-1
Without hinged lid, yellow RAL 1018
230
16
6

2.5

5TE6 810

1 unit

027

0.089

2.5

5TE6 802

1 unit

027

0.093

Socket outlets
according to CEI 23-50
With hinged lid
230

16

Socket outlets
according to CEE 7 Standard sheet V
Without hinged lid, with grounding pin
230
16
6

2.5

5TE6 803

1 unit

027

0.089

2.5

5TE6 804

1 unit

027

0.088

Hinged lids for 5TE6 socket outlets

2.5

5TE9 120

1 unit

027

0.019

UL 498 socket outlets


Without hinged lid
125

15

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

9/11

Siemens AG 2011

Transformers, Bells and Socket Outlets


REG socket outlets

More information
Hinged lid for simple application

The hinged lid can be opened at an angle greater than 180 degrees.

In order to make sure that it is possible to work on the distribution board in


the event of a power failure, we recommend that the infeed socket outlet is
fed using a short-circuit current proof cable installation and a separate fuse.
The yellow socket outlet must be used for this purpose.

9/12

Siemens LV 10.1 2011

By pulling on the hinges, the covers stay open, which facilitates plugging in.
The hinged lids can be retrofitted on all versions.

10

Siemens AG 2011

Busbar Systems
10/2

Introduction

10/3

General data

10/6
10/7

40 mm Busbar Systems
Introduction
Base assemblies up to 400 A

10/24

60 mm Busbar Systems
Introduction
Base assemblies up to 630 A
Base assemblies up to 1600 A
Infeed and connection components
Busbar adapters and device holders
Connector for 3NP1 fuse switch
disconnectors
Accessories

10/26

Distribution Board Components

10/28

Built-in Components

10/8
10/9
10/13
10/14
10/16
10/23

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical Specifications
under Entry List:
- Updates
- Downloads
- FAQ
- Manuals
- Characteristic curves
- Certificates

10

and at
www.siemens.com/lowvoltage/configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
Introduction

Page

Application

Standards

Used in
Non-residential
buildings

Residential
buildings

Industry

Overview
Devices

40 mm Busbar Systems

10/6

Base assemblies up to 400 A,


busbar supports,
busbars,
covers for the touch protection

EN 13601
IEC 60439-1
IEC 61439-2

--

Base assemblies up to 400 A

10/7

Base assemblies up to 400 A,


busbar supports,
busbars,
covers for the touch protection

EN 13601
IEC 60439-1
IEC 61439-2

--

60 mm Busbar Systems

10/8

Base assemblies up to 630 A,


overview with different devices

EN 13601
IEC 60439-1
IEC 61439-2
UL 508 A

--

Base assemblies up to 630 A

10/9

Base assemblies up to 630 A,


busbar supports,
busbars,
covers for the touch protection

EN 13601
IEC 60439-1
IEC 61439-2
UL 508 A

--

Base assemblies up to 1600 A

10/13

Base assemblies up to 1600 A,


busbar supports,
busbars,
covers for the touch protection

EN 13601
IEC 60439-1
IEC 61439-2
UL 508 A

--

Infeed and connection components

10/14

Feeder for busbar systems,


terminals...

EN 13601
IEC 60439-1
IEC 61439-2
UL 508 A

--

Busbar adapters and device holders

10/16

Busbar adapters and device


holders for the design of
3RV2/3RT2 load feeders

EN 13601
IEC 60439-1
IEC 61439-2
UL 508 A

--

Distribution board components

10/26

Longitudinal stays, assembly kits, IEC 60439-1

covers for the touch protection


IEC 61439-3
DIN VDE 0603-1

--

Built-in components

10/28

3-pole NEOZED bus-mounting


bases or DIAZED bus-mounting
bases,
NEOZED bus-mounting switch
disconnectors,
LV HRC fuse switch disconnectors
and busbar device adapters.

--

NSE0_02123

NSE0_02112

10

16(B

10/2

Siemens LV 10.1 2011

IEC 60947-3
EN 60947-3
IEC 60269
EN 60269

Siemens AG 2011

Busbar Systems
General data

Overview
The use of busbar systems with their versatile rail-adaptable
connection, switching and installation devices is an ideal and
cost-effective electrotechnical enhancement of modern distribu-

tion boards due to their small footprint, compact design and


quick assembly contacts. Mounting is implemented on longitudinal stays. The busbar spacing is 60 mm.

6
5

7
8

4
3
2

I201_13633

$ Longitudinal stays
% Busbar supports, 3-phase
& Copper busbars
( Terminals
) Support for blanking cover
* Blanking covers
+ Supports
, Touch protection cover
- Busbar support, single-phase

Benefits

10

Design

Notable cost reduction compared to conventional installation in


switchgear and control cabinets due to the following reasons:
Mechanical fixing and electrical contacting in a single step
No access wiring and fewer busbar terminals used
Double use of the busbar space
Clear arrangement
Straightforward replacement of individual devices or whole
combinations
High operational safety through finger-safe covering of the
adapters and device holders

8US busbar systems with 60 mm busbar center-to-center clearance as well as flat copper profiles have become firmly established on the world market.

All the above advantages are felt especially in cases where


many tap-off units of the same performance range are required.

The busbar runs prove most advantageous when the incoming


supply is centrally located and the load is distributed symmetrically on both sides.

Application
8US busbar systems are used for the direct busbar-mounting of
current-limiting devices (protection devices) such as fuse switch
disconnectors and motor starter protectors/circuit breakers as
well as complete load feeders.
8US busbar systems are designed for horizontal mounting of the
busbars.

The permissible busbar temperature is decisive when dimensioning the busbars. The busbar temperature is dependent on
the current and the current distribution, on the busbar cross-section and the busbar surface, on the position of the busbars, convection and the ambient temperature. The values stated in the
following table can only be considered as guide values because
the conditions vary with each location. The values are based on
uninterrupted current over the whole busbar length.

Function
Short-circuit strength
The short-circuit strength of the busbar system is dependent on
the distance of the busbar supports and on the busbar crosssection.
The short-circuit strength of the whole system is dependent on
the short-circuit strength of the busbars and of the adapters with
circuit breakers or switch disconnectors. If one of these values
is lower than the prospective short-circuit current at the place of
installation, a current-limiting protective device has to be
mounted upstream of the 8US busbar system. This may also be
mounted as a feeder circuit breaker on the busbar system itself.

Siemens LV 10.1 2011

10/3

Siemens AG 2011

Busbar Systems
General data

Technical specifications
Uninterrupted current for busbars, E-Cu bare, at 35 C ambient temperature according to DIN 43671
Bar dimensions

System

Uninterrupted current at a busbar temperature of


65 C

85 C

105 C

mm

mm

12 5
15 5

40 + 60
40 + 60

188
222

248
293

295
349

20 5
25 5
30 5

60
60
60

274
327
379

362
432
500

430
513
595

12 10
20 10
30 10

40 + 60
60
60

302
427
573

398
564
756

474
670
900

Special profile up to 1600 A

60

1020

1020

1600

General technical specifications


Rated insulation voltage Ui

V AC 1000

Short-circuit strength
Of 8US1 busbar device adapter

Current limiting due to associated motor starter protectors/circuit breakers/load feeders


up to 50 kA

Of the busbar systems

see Characteristic Curves

Material of the 8US1 busbar supports, busbar device


adapters and device holders

Fiberglass-strengthened polyamide

Color

RAL 7035, light gray

Thermal stability (minimum values)

10

Busbar supports, busbar device adapters,


device holders, infeed and covers

120

AWG connecting cables

105 / 150

Cover profiles

110

Bases, partitions, edge profiles and blanking covers

70
Take care when machining that no cracks are formed. A cross-cut circular saw with the
following characteristic values has proven successful in cutting cover profiles for busbars:

Machining of plastic profiles

D = 300 mm, B 0 2.2 mm,


T = 120 R (5 negative replaceable tooth at a cutting rate of 50 ... 60 m/s)
Tooth feed 0.05 ... 0.1 mm
The plastic parts are secured so that vibration is ruled out.
Approvals
UR, CSA, cuUS- Listed

Busbar supports, busbar device adapters, device holders and terminals.

Technical specifications of the system components


Infeed, connection modules, three-phase
Center-to-center clearance

mm

Current carrying capacity of the terminal points


A
The specified current carrying capacities reflect the thermal load capability of the terminal points under favorable
conditions (with the largest conductors it is possible to
connect). This does not invalidate the assignment of conductor cross-sections and current carrying capacities as
defined in national and international specifications.

5SH3 538

5SH3 535

8US19 21-1BA00

8US19 21-1AA00

60

60

60

60

80

560

300

440

Tightening torque

Nm

--

30

8 ... 10

12 ... 15

Clamping space W H

mm

--

--

10 15

15 15

Conductors that can be used

mm2

1.5 ... 16
Cu, re, rm, f, f+AE
(reduction of the
maximum conductor
cross-sections may
be required)

150 ... 300


Cu, Al
(connections with aluminum conductors
are not maintenance
free), rm, sm, f

6 ... 50 (70)
Cu, rm, f, f+AE
(reduction of the
maximum conductor
cross-sections may
be required), la.
Cu 6 9 0.8

35 ... 120
Cu, rm, f, f+AE
(reduction of the
maximum conductor
cross-sections may
be required), la.
Cu 6/10 15.5 0.8

10/4

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
General data

Characteristic curves
Characteristic curves as a function of rated peak withstand current
40 mm Busbar Systems

pk

60 mm Busbar Systems
pk

kA
NSE0_01546

55
50
 45
2 x 12x5
40
35

1 x 12x5
30
25
20
200 250 300 350 400 mm

 Surge current

pk

 Spacing of busbar supports


 5-pole busbar supports

pk

kA

NSE0_00342b

90

kA
NSE0_01547

55
50
45
2 x 15x5
40
35
1 x 15x5
30
25
20
200 250 300 350 400 mm


Surge current

Spacing of busbar supports

80
75
70
65
60

30x10
30x5

55
50
45
40 20x5
12x5
35

pk

30

300

20x10
12x10
400

500

600 700 mm 800 900

2
1

Surge current

pk

2 Spacing of busbar supports

10

Siemens LV 10.1 2011

10/5

Siemens AG 2011

Busbar Systems
40 mm Busbar Systems
Introduction

Overview

The 40 mm busbar system for the lower performance range up to 400 A: Terminals and covers for infeed and connection components

The 40 mm busbar system is used in machine engineering and


distribution boards, in meter cabinets and in power distribution
systems of the low performance range up to 400 A.

10

The busbar cross-sections are adapted to the rated currents and


are available in the sizes 12 x 5 mm, 12 x 10 mm, 15 x 5 mm and
15 x 10 mm. The basic system is configured without covers. If
touch protection is required, this is possible with busbar covers.
Terminals round off the product range of the 40 mm busbar system.

10/6

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
40 mm Busbar Systems
Base assemblies up to 400 A

Overview
2
1

4
5

NSE0_02112

1 Flat copper profile


2 Busbar support
3 Cover profile

4 Inlay part
5 Covering cap

40 mm busbar system: Base assembly up to 400 A

Selection and ordering data


Description

DT

Order No.

Price
per PU

PU
(UNIT,
SET,
M)

PS*

PG

Weight
per PU
approx.
kg

%() Busbar supports


End and intermediate holders for
flat copper profiles
12 mm x 5 mm, 12 mm x 10 mm,
15 mm x 5 mm, 15 mm x 10 mm

8US19 03-3AB00

1 unit

143

0.184

8US19 03-5AA00

1 unit

143

0.137

B
B

8WC5 123
8WC5 121

1
1

1 unit
1 unit

143
143

1.100
1.550

3-pole, with inside fixing


(PU = 2 busbar supports including
inlay parts for bar thickness 5 mm
and lateral finger-safe covers)

8US19 03-3AB00
5-pole,
L1L3 + N +
12 mm x 5 mm and 12 mm x 10 mm PE/N
with inside fixing

8US19 03-5AA00
$ Flat copper profiles
(flat profile, approx. 2.4 m long,
bare, acc. to EN 12167)
8WC5

12 mm 5 mm
15 mm 5 mm
& Cover profiles for busbars
12 mm 5 mm

1000 mm long

8US19 22-2CA00

10 units

143

0.200

15 mm 5 mm

1000 mm long

8US19 22-2AA00

10 units

143

0.156

8US19 22-2CA00

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/7

10

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Introduction

Overview

The 60 mm busbar system for the medium and top performance range up to 1600 A, here for example with the 3NP1 switch disconnector, size 3

10

The 60 mm busbar system is used preferably in control cabinet


installation, in motor control centers and in power distribution
systems of the medium power range (630 A) and top performance range (1600 A, special profile).
The 60 mm busbar system can be configured as a basic system
without covers. The busbar cross-sections are available in the
sizes 12 x 5 mm to 30 x 10 mm and as a special profile.
Busbar adapters for SIRIUS, 3VL circuit breakers, 3KA and 3KL
switch disconnectors, and 3NP1 and 3NP5 fuse switch disconnectors offer numerous options for configuring this busbar system. Feeder units, terminals and other accessories open up a
large range of application.
Busbars with a special profile are suitable for applications up to
1600 A. All components of the 60 mm busbar system can be fitted.

10/8

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Base assemblies up to 630 A

Overview


NSE0_02123




 Flat copper profile

 Cover profile

 Busbar supports

 Support for blanking covers

 End cover

 Blanking cover

60 mm busbar system: Base assemblies up to 630 A

Selection and ordering data


Longitudinal stays and assembly kits
Description

Dimensions

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

mm

Weight
per PU
approx.
kg

Longitudinal stays
For mounting the assembly kits in unequipped distribution boards, two longitudinal stays are required
Height
600
750
900

A
A
A

8GK4 851-4KK00
8GK4 851-5KK00
8GK4 851-6KK00

1
1
1

1 set
1 set
1 set

039
039
039

1.000
1.300
1.500

1050
1200
1350

A
A
A

8GK4 851-7KK00
8GK4 851-8KK00
8GK4 852-8KK00

1
1
1

1 set
1 set
1 set

039
039
039

1.800
2.080
2.340

466 mm

300 250
300 500

A
A

8GK4 801-2KK13
8GK4 801-2KK23

1
1

1 unit
1 unit

039
039

0.500
0.700

716 mm

300 750

8GK4 801-2KK33

1 unit

039

0.900

216 mm
466 mm

450 250
450 500

A
A

8GK4 801-3KK13
8GK4 801-3KK23

1
1

1 unit
1 unit

039
039

0.650
0.900

716 mm

450 750

8GK4 801-3KK33

1 unit

039

1.150

Assembly kits
Comprising touch protection cover
and 4 supports
Cutout width for three-phase busbar systems
216 mm

1 set = 2 stays

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/9

10

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Base assemblies up to 630 A
Busbar support and end cap
Description

Connections

Standard
plus
UL, CSA

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

% Busbar supports
End and intermediate holders for flat copper profiles
12 mm x 5 mm, 12 mm x 10 mm,
15 mm x 5 mm, 15 mm x 10 mm,
20 mm x 5 mm, 20 mm x 10 mm,
25 mm x 5 mm, 25 mm x 10 mm,
30 mm x 5 mm, 30 mm x 10 mm
3-pole, with fixing screws

8GK9 711-0KK03

1 unit

039

0.300

8GK9 711-0KK03
3-pole, with outside fixing

L1L3

8US19 23-2AA01

10 units

143

0.200

3-pole, with inside fixing

L1L3

8US19 23-3AA01

10 units

143

0.200

4-pole, with inside fixing

L1L3 + PE/N

8US19 23-4AA00

10 units

143

0.269

8US19 23-5AA00

10 units

143

0.200

5SH3 540

1 unit

016

0.059

8US19 23-1AA01

1 unit

143

0.200

10
8US19 23-3AA01
2-pole, with outside fixing

8US19 23-5AA00
N/PE busbar supports
1-pole, plus
for flat copper profile
for 5/10 mm busbar

PE/N

5SH3 540
1-pole, in addition for copper PE/N
profiles 6 x 6 mm,
mounting on 8US1923-2AA01
3-pole busbar supports or free
standing

UL508

8US19 23-1AA01

* You can order this quantity or a multiple thereof.

10/10

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Base assemblies up to 630 A
Description

Connections

Standard
plus
UL, CSA

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

End and intermediate holders for flat copper profiles


5 mm x 20 mm, 10 mm x 20 mm, 10 mm x 30 mm
L1L3

UL 508A1)

8US19 23-3UA01

10 units

143

0.205

For 8US19 23-2AA01,


3AA01 and -3UA01

L1L3

UL 508A

8US19 22-1AC00

10 units

143

0.020

4-pole,
for 8US19 23-4AA00
1 pack = 2 units
(1x right, 1x left)

L1L3 + PE/N

8US19 22-1AB00

1 unit

143

0.055

Height 230 mm (3-pole)

5SH3 533

4 units

016

0.035

Height 290 mm
(4-pole or
3-pole + cable duct),
1 pack = 2 units
(1x right, 1x left)

5SH3 534

1 4/40 units

016

0.045

3-pole, with inside fixing

8US19 23-3UA01
& End covers
For covering unterminated
busbar ends

For 5SH3 532 holder


8US19 22-1AC00
5SH3 534

10

Covers, supports for blanking covers, flat copper profiles and busbar connection parts
Description

Length Width

mm

Standard
plus
UL, CSA

DT

Order No.

mm

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

( Cover profiles for busbars


12 mm x 5 mm

1000

15 mm x 5 mm,
20 mm x 5 mm,
25 mm x 5 mm,
30 mm x 5 mm

1000

12 mm x 10 mm,
15 mm x 10 mm,
20 mm x 10 mm,
25 mm x 10 mm,
30 mm x 10 mm

1000

8US19 22-2CA00

10 units

143

0.200

UL 508A

8US19 22-2AA00

10 units

143

0.156

UL 508A

8US19 22-2BA00

10 units

143

0.105

8US19 22-2CA00

8US19 22-2AA00

) Supports for blanking covers)


Mounting on busbar
(2 units per section of
blanking cover)

1000

190

UL 508

5SH3 536

1 4/160 units

016

0.037

Mounting on 5SH3 536


1000
support for blanking covers

202

UL 508A

5SH3 537

016

1.130

5SH3 536
* Blanking covers
2 units

5SH3 537
1)

Only with base plate 8US19 22-2UA01

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/11

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Base assemblies up to 630 A
Description

Length Cross- Standard DT Order No.


section plus
UL, CSA
mm

mm2

1100

--

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

Base plates
For 3-pole system,
width 230 mm

UL 508A A

8US19 22-2UA01

2 units

143

0.200

8US19 22-2UA01
$ Flat copper busbar (flat profile, bare)
Flat copper profile for universal applications
12 x 5 mm, current up to 200 A

2400

60

EN 12167 B

8WC5 123

1 unit

143

1.100

15 x 5 mm, current up to 250 A

2400

75

EN 12167 B

8WC5 121

1 unit

143

1.550

20 x 5 mm, current up to 320 A

2400

100

EN 12167 B

8WC5 126

1 unit

143

1.780

25 x 5 mm, current up to 400 A

2400

125

EN 12167 B

8WC5 131

1 unit

143

2.240

20 x 10 mm, current up to 520 A

2400

200

EN 12167 B

8WC5 128

1 unit

143

3.200

30 x 5 mm, current up to 447 A

2400

150

EN 12167 B

8WC5 133

1 unit

143

2.680

30 x 10 mm, current up to 630 A

2400

300

EN 12167 B

8WC5 134

1 unit

143

5.360

EN 12167
EN 12167
EN 12167
EN 12167
EN 12167
EN 12167
EN 12167
EN 12167
EN 12167

A
A
A
A
A
A
A
A
A

8GK9 731-0KK10
8GK9 731-0KK20
8GK9 731-0KK30
8GK9 731-0KK40
8GK9 731-0KK50
8GK9 733-0KK20
8GK9 733-0KK30
8GK9 733-0KK40
8GK9 733-0KK50

1
1
1
1
1
1
1
1
1

5 units
5 units
5 units
5 units
5 units
5 units
5 units
5 units
5 units

039
039
039
039
039
039
039
039
039

0.100
0.330
0.500
0.660
0.830
0.570
0.850
1.120
1.470

Flat copper profile for ALPHA distribution boards

10

12 x 5 mm, current up to 250 A

250
500
750
1000
1250
500
750
1000
1250

60
60
60
60
60
60
60
60
60

20 x 5 mm, current up to 320 A

250

100

EN 12167 A

8GK9 733-0KK10

5 units

039

0.290

30 x 5 mm, current up to 447 A

250
500
750
1000
1250

150
150
150
150
150

EN 12167
EN 12167
EN 12167
EN 12167
EN 12167

A
A
A
A
A

8GK9 735-0KK10
8GK9 735-0KK20
8GK9 735-0KK30
8GK9 735-0KK40
8GK9 735-0KK50

1
1
1
1
1

5 units
5 units
5 units
5 units
5 units

039
039
039
039
039

0.400
0.750
1.460
2.170
2.880

30 x 10 mm, current up to 630 A

250
500
750
1000
1250

300
300
300
300
300

EN 12167
EN 12167
EN 12167
EN 12167
EN 12167

A
A
A
A
A

8GK9 736-0KK10
8GK9 736-0KK20
8GK9 736-0KK30
8GK9 736-0KK40
8GK9 736-0KK50

1
1
1
1
1

5 units
5 units
5 units
5 units
5 units

039
039
039
039
039

0.750
1.720
2.600
3.400
4.600

12 x 5 mm, current up to 200 A

2000

60

EN 12167 B

8WC5 051

1 unit

143

1.100

15 x 5 mm, current up to 250 A

2000

75

EN 12167 B

8WC5 052

1 unit

143

1.550

20 x 5 mm, current up to 320 A

2000

100

EN 12167 B

8WC5 053

1 unit

143

1.780

25 x 5 mm, current up to 400 A

2000

125

EN 12167 B

8WC5 054

1 unit

143

2.240

30 x 5 mm, current up to 447 A

2000

150

EN 12167 B

8WC5 055

1 unit

143

2.680

20 x 10 mm, current up to 520 A

2000

200

EN 12167 B

8WC5 063

1 unit

143

3.200

30 x 10 mm, current up to 630 A

2000

300

EN 12167 B

8WC5 065

1 unit

143

5.360

Extension terminals

--

--

--

8JK3 201

10 set

046

0.020

40

--

--

8US19 21-2BE00

6 units

143

0.070

55

--

--

8US19 21-2BF00

1 12 units

143

0.070

$ Flat copper profile, tinned

for busbars 12 x 5 mm
tightening torque 6.0 Nm
(busbar not included
1 set = 2 units)
8JK3 20
Busbar connection pieces

8US19 21-2BE00

For flat profiles (max. 630 A)


20 mm 5 mm,
20 mm 10 mm,
25 mm 5 mm,
25 mm 10 mm,
30 mm 5 mm,
30 mm 10 mm

8US19 21-2BF00

For flat profiles (max. 630 A)


12 mm 5 mm,
12 mm 10 mm,
15 mm 5 mm,
15 mm 10 mm,
20 mm 5 mm,
20 mm 10 mm

* You can order this quantity or a multiple thereof.

10/12

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Base assemblies up to 1600 A

Overview


NSE0_02113

Flat copper profile

Busbar support

End cover

60 mm busbar system: Base assembly up to 1600 A

Selection and ordering data


Description

Standard
plus
UL, CSA

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.
kg

Busbar supports
3-pole, end and intermediate
holder with finger-safe busbar
cover (1 pack = 2 busbar supports + finger-safe end covers)

8US19 43-3AA00

1 unit

143

1.310

8US19 48-2AA00

1 unit

143

15.360

8US19 22-2DA00

5 units

143

0.200

For special profiles/TT profiles up to 1600 A

8US19 41-2BF00

3 units

143

1.134

Barriers, closed
76 mm wide, 2400 mm long
For additional touch protection at the top/bottom

8US19 22-1JA00

1 unit

143

0.700

UL 508A

5SH3 536

1 4/160 units

016

0.037

UL 508A

5SH3 537

016

1.130

L1L3

8US19 43-3AA00
Flat copper profiles
(approx. 2.4 m long, tinned)
Special profile up to 1600 A, cross section 720 mm2
8US19 48-2AA00
Cover profiles
For flat copper profiles, length 1000 mm
Busbar connection pieces

76

48

8US19 41-2BF00

NSB0_91362b

2400

8US19 22-1JA00
Supports for blanking covers
Mounting on busbar
(2 units per section of blanking cover),
height 1000 mm

5SH3 536
Blanking covers
Mounting on 5SH3 536 support
for blanking covers,
height 1000 mm

2 units

5SH3 537
* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/13

10

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Infeed and connection components

Overview

60 mm busbar system: Terminals and covers for infeed and connection components

Selection and ordering data


Description

10

Length Width

Conductor DT
crosssection

mm

mm2

mm

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Infeeds
Terminal plate with
cover
3-pole

200

20

1.5 ...16

5SH3 538

5 units

016

0.181

3-pole

200

54

6 ... 50

8US19 21-1BA00

1 unit

143

0.397

3-pole

200

81

35 ... 120

8US19 21-1AA00

1 unit

143

0.607

8US12 00-0AA00

1 unit

143

0.142

150 ... 300 C

5SH3 535

1 unit

016

1.608

120 ... 300 A

8US19 41-2AA03

1 unit

143

0.160

8US19 21-1AA00
Outgoing modules for PE/N
Connection module
242
for 4-pole (PE/N) up to
16 mm must be attached to an
adapter/device holder

18

SR60 terminal plates


3-pole with cover
(shown without
cover)

5SH3 535
Terminal sets
3-pole
without cover
for round cables

8US19 41-2AA03

* You can order this quantity or a multiple thereof.

10/14

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Infeed and connection components
Description

Conductor DT
crosssection

Order No.

mm2

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Terminal sets
3-pole without cover
for flat bars up to
32 x 20 mm

8US19 41-2AA04

1 unit

143

0.140

Covers for 8US19 41-2AA03/04


terminal set

8US19 22-1GC00

1 unit

143

0.150

100 100 units


100 50 units
1 50 units
1 50 units

143
143
143
143

0.100
4.600
0.072
0.107

8US19 41-2AA04

8US19 22-1GC00
Terminals for circular conductors
5 mm busbar thickness1)
12 mm 5 mm,
15 mm 5 mm,
20 mm 5 mm,
25 mm 5 mm,
30 mm 5 mm

1.5 ... 16
4 ... 35
16 ... 70
16 ... 120

}
}
}
}

8US19 21-2AA00
8US19 21-2AB00
8US19 21-2AD00
8US19 21-2AC00

1.5 ... 16
4 ... 35
16 ... 70
16 ... 120

}
}
}
}

8US19 21-2AA01
8US19 21-2AB01
8US19 21-2AD01
8US19 21-2AC01

1
1
1
1

15 units
15 units
15 units
15 units

143
143
143
143

0.020
0.020
0.020
0.020

20 mm 5 mm, 25 mm 5 mm,
30 mm 5 mm

95 ... 185 }
150 ... 300 }

8US19 41-2AA01
8US19 41-2AA02

1
1

6 units
3 units

143
143

0.315
0.425

Terminals

10 mm busbar thickness
12 mm 10 mm,1)
15 mm 10 mm,1)
20 mm 10 mm,
25 mm 10 mm,
30 mm 10 mm

1.5 ... 16
4 ... 35
16 ... 70
16 ... 120

}
}
}
}

8US19 21-2BA00
8US19 21-2BB00
8US19 21-2BD00
8US19 21-2BC00

1 100 units
1 50 units
1 50 units
1 50 units

143
143
143
143

0.020
0.040
0.070
0.100

1.5 ... 16
4 ... 35
16 ... 70
16 ... 120

}
}
}
}

8US19 21-2BA01
8US19 21-2BB01
8US19 21-2BD01
8US19 21-2BC01

1
1
1
1

15 units
15 units
15 units
15 units

143
143
143
143

0.020
0.040
0.070
0.100

20 mm 10 mm,
25 mm 10 mm,
30 mm 10 mm

95 ... 185 }
150 ... 300 }

8US19 41-2AA01
8US19 41-2AA02

1
1

6 units
3 units

143
143

0.315
0.425

Terminals

Covers for terminals for circular conductors


(attachment to busbar)
For terminals up to 120 mm2
200 mm long, 84 mm wide

8US19 22-1GA00

10 units

143

0.126

2 2)

8US19 22-1GA02

1 unit

143

0.696

For cable lugs up to 240 mm2,


10 mm bar thickness
(threaded bolts M10)

8US19 41-2AC00

6 units

143

0.368

For copper bars or laminated conductors


20 mm x 5 mm,
20 mm x 10 mm,
25 mm x 5 mm,
25 mm x 10 mm,
30 mm x 5 mm,
30 mm x 10 mm

8US19 41-2BB00

6 units

143

0.307

For 2 x 40 mm x 10 mm

8US19 41-2BA00

3 units

143

0.824

For terminals up to 300 mm


200 mm long, 270 mm wide
8US19 22-1GA00
Terminals

8US19 41-2AC00

8US19 41-2BB00

8US1941-2BA00
1)

Cannot be used on a special profile up to 1600 A.

2)

Only for 20 mm 5 mm, 20 mm 10 mm, 25 mm 5 mm, 25 mm 10 mm,


30 mm 5 mm and 30 mm 10 mm.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/15

10

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders

Overview

60 mm busbar system: Busbar adapters and device holders

All busbar device adapters and device holders are designed for
copper busbars according to DIN 46433, width 12 to 30 mm,
thickness 5 mm and 10 mm, and special profiles up to 1600 A.

10

Selection and ordering data


For SIRIUS 3RV2/3RT2 load feeders
Welded connection conductor resistant up to 150 C
Busbar
device
adapters
for

Number Adapter
Connecting cables
StanDT Order No.
of
dard
mount- Length Width Cross- Tem- Rated Rated Addiing rails
secpera- current volttionally
(35 mm)
tion
ture
age
UL,
max.
CSA
mm

mm

AWG

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Size S00 devices with screw connection


1

200

45

12

150

25

690

UL 508 }

8US12 51-5DS10

1 unit 143

0.183

Direct-on- 1
line starters

200

45

12

150

25

690

UL 508 }

8US12 51-5DS10

1 unit 143

0.183

MSPs/
circuit
breakers

Device
holder with
3RA21 20

260

45

12

150

25

690

UL 508 }

8US12 51-5DT10

1 unit 143

0.183

Reversing
starters
+

200

45

12

150

25

690

UL 508 }

8US12 51-5DS10

1 unit 143

0.183

Device
holders

200

45

--

--

--

--

UL 508 }

8US12 50-5AS10

1 unit 143

0.183

Size S00 devices with screw connection

Device
holder with
3RA21 20

MSPs/
circuit
breakers

200

45

12

150

25

690

UL 508

8US12 51-5DS11

1 unit 143

0.183

MSPs/
circuit
breakers

260

45

12

150

25

690

UL 508 }

8US12 51-5DT11

1 unit 143

0.183

Direct-on- 1
line starters

260

45

12

150

25

690

UL 508 }

8US12 51-5DT11

1 unit 143

0.183

Reversing
starters
+

260

45

12

150

25

690

UL 508 }

8US12 51-5DT11

1 unit 143

0.183

Device
holders

260

45

--

--

--

--

UL 508 }

1 unit 143

0.183

+
8US12 50-5AT10

* You can order this quantity or a multiple thereof.

10/16

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders
Busbar
device
adapters
for

Number Adapter
Connecting cables
StanDT Order No.
of
dard
mount- Length Width Cross- Tem- Rated Rated Addiing rails
secpera- current volttionally
(35 mm)
tion
ture
age
UL,
max.
CSA
mm

mm

AWG

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Size S0 devices with screw connection


1

260

45

10

150

32

690

UL 508 }

8US12 51-5NT10

1 unit 143

0.183

Direct-on- 1
line starters

260

45

10

150

32

690

UL 508 }

8US12 51-5NT10

1 unit 143

0.183

Reversing
starters
+

260

45

10

150

32

690

UL 508 }

8US12 51-5NT10

1 unit 143

0.183

Device
holders

260

45

--

--

--

--

UL 508 }

8US12 50-5AT10

1 unit 143

0.183

MSPs/
circuit
breakers

Device
holder with
3RA22 20

Size S0 devices with spring-type terminals


1

260

45

10

150

32

690

UL 508 }

8US12 51-5NT11

1 unit 143

0.183

Direct-on- 1
line starters

260

45

10

150

32

690

UL 508 }

8US12 51-5NT11

1 unit 143

0.183

Reversing
starters
+

260

45

10

150

32

690

UL 508 }

8US12 51-5NT11

1 unit 143

0.183

Device
holders

260

45

--

--

--

--

UL 508 }

1 unit 143

0.183

MSPs/
circuit
breakers

Device
holder with
3RA22 20

+
8US1250-5AT10

10

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/17

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders
For SIRIUS 3RV1/3RT1 load feeders
Busbar
Number Adapter
device
of
adapters for mount- Length Width
ing rails
(35 mm)

Connecting cables

Standard

Cross- Tem- Rated Rated


secpera- current volttion
ture
age
max.

Additionally
UL,
CSA

DT Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

mm

mm

AWG

182

55

105

56

690

8US12 61-5FM08

1 unit 143

0.263

Contactors 1
+ overload
relay

182

55

105

56

690

8US12 61-5FM08

1 unit 143

0.263

Directon-line
starters

242

55

105

56

690

8US12 61-5FP08

1 unit 143

0.292

Reversing 1
starter
adapter
+
Device
-holders1)
+
Connecting -wedges
(2 units
needed for
attachment)

242

55

105

56

690

8US12 61-5FP08

1 unit 143

0.292

242

54

--

--

--

--

--

+
8US12 60-5AP00

1 unit 143

0.243

--

--

--

--

--

--

--

+
8US19 98-1AA00

100 100 units 143

0.100

600

UR,
CSA

8US12 11-4TR00

Size S2 devices
MSPs/
circuit
breakers

Reversing
feeder

Connecting
wedge

Size S3 devices with screw connection


MSPs/
circuit
breakers

10

--

215

72

105

80

1 unit 143

0.470

Device holder
1)

Spacer and fixing screw for reversing contactor are included in the scope
of supply.

* You can order this quantity or a multiple thereof.

10/18

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders
For motor starter protectors/circuit breakers and load disconnect switches which require busbar device adapters for
mounting on busbars
Busbar device Adapter
Connecting cables
Standard DT Order No.
adapters for
Length Width Type
Rated Rated Addicurrent voltage tionally
UL, CSA
mm

mm

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3VL circuit breakers1)

8US10 11-4SL01

3VL12)

175

108

Busbars

160

690

8US12 11-4SL01

1 unit

143

0.597

3VL22)

175

108

Busbars

160

690

8US12 11-4SL01

1 unit

143

0.597

3VL32)

175

108

Busbars

250

690

8US12 11-4SL00

1 unit

143

0.662

3VL1 to 3VL4 320


and also with
RCD module2)

184

M10 stud
terminal

400

690

1 unit

143

2.769

8US12 10-4AF00
+
8US19 27-4AF01

1 unit

143

0.575

3VL5

184

M8 stud
terminal

580

690

8US12 13-4AF00

1 unit

143

2.880

325

3VL UL circuit breakers


VL150X UL
CG-Frame

190

105

Tubular
contacts

150

600

UL 508A A

8US12 13-4AQ01

1 unit

143

1.020

VL150 UL
DG-Frame

190

105

Tubular
contacts

150

600

UL 508A A

8US12 13-4AQ03

1 unit

143

1.020

VL250 UL
FG-Frame

190

105

Tubular
contacts

250

600

UL 508A A

8US12 13-4AQ03

1 unit

143

1.020

VL400 UL
JG-Frame

296

140

Tubular
contacts

400

600

UL 508A A

8US12 13-4AH00

1 unit

143

1.900

VL400X UL
LG-Frame

296

140

Tubular
contacts

540

600

UL 508A A

8US12 13-4AH00

1 unit

143

1.900

8US12 13-4AQ01

10
8US12 13-4AH00
3KA und 3KL switch disconnectors
3KA523)
3KA533)
3KL523)
3KL533)

320

184

M10 stud
terminal

630

690

8US12 10-4AF00

1 unit

143

2.769

3KA553)
3KA573)
3KA583)
3KL553)
3KL573)

320

250

M10 stud
terminal

630

690

8US12 10-4AG00

1 unit

143

3.060

3NP5 fuse switch disconnectors


3NP50 60
(NH00)

175

108

Busbars

160

690

8US12 10-4AF00

1 unit

143

2.769

3NP524),
3NP534),
3NP545)

320

250

M10 stud
terminals

630

690

8US12 10-4AG00

1 unit

143

3.060

1)

Observe the short-circuit strength of the busbar system.


Short-circuit strength > 50 kA on request.

2)

Usable only for 3VL circuit breakers with line-side box terminals.

3)

Without connecting cables. The connecting cable between adapter and


device should be manufactured in accordance with the rated current as a
round cable, e.g. H07V-R with cable lug, or as a flat conductor for a M10
stud terminal.

4)

Without connecting cables. The connecting cable between adapter and


device should be manufactured in accordance with the rated current as a
round cable, e.g. H07V-R with cable lug, or as a flat conductor for a M10
stud terminal.

5)

Without connecting cables. The connecting cable between adapter and


device should be manufactured in accordance with the rated current as a
round cable, e.g. H07V-R, bared at both ends for tunnel terminals.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/19

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders
SIRIUS 3RA6 compact feeder according to IEC and UL
Welded cable connection resistant up to 105 C
Busbar
device
adapter
for

Number Adapter
Connecting cables
StanDT Order No.
of
dard
mount- Length Width Cross- Tem- Rated Rated Addiing rails
section pera- current volttionally
(35 mm)
ture
age
UL, CSA
max.
mm

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

mm

AWG

45

10

105

32

690

UR, CSA }

8US12 11-1NS10

1 unit 143

0.337

8US12 11-1NS10

1 unit 143

0.337

1 unit 143

0.239

Size equivalent to 3RA61


Directon-line
starters

200

Device
holder
Size equivalent to 3RA62

10

Reversing 1
starters
+

200

45

10

105

32

690

UR, CSA }

Device
holders

200

45

--

--

--

--

UL 508

+
}

8US1 250-1AA10

Device
holder

* You can order this quantity or a multiple thereof.

10/20

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders
For universal device design
Number of Adapter
Connecting cables
mounting Length Width Cross- Tem- Length Rated
rails
section peracurrent
(35 mm)
ture
max.
mm

mm

AWG

mm

DT Order No.
Rated
voltage

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Devices 45 mm wide
Device holder for side mounting onto busbar device adapter,
no electrical contact
1

200

45

--

--

--

--

--

8US12 50-1AA10

1 unit 143

0.239

200

45

--

--

--

--

--

8US12 50-5AS10

1 unit 143

0.183

260

45

--

--

--

--

--

8US12 50-5AT10

1 unit 143

0.183

8US1250-1AA10

8US1250-5AS10

8US1250-5AT10
Devices 45 mm and 72 mm wide
Busbar device adapter with connection conductors for contact with
busbars, welded connection conductor resistant up to 150 C

8US1251-5DS10

200

45

12

150

165

25

690

8US12 51-5DS11

1 unit 143

0.183

200

45

12

150

99

25

690

8US12 51-5DS10

1 unit 143

0.183

260

45

12

150

99

25

690

8US12 51-5DT10

1 unit 143

0.183

260

45

12

150

165

25

690

8US12 51-5DT11

1 unit 143

0.183

260

45

12

150

99

32

690

8US12 51-5NT10

1 unit 143

0.183

260

45

12

150

165

32

690

8US12 51-5NT11

1 unit 143

0.183

200

45

10

105

118

32

690

8US12 11-1NS10

1 unit 143

0.337

--

215

72

105

210

100

690

8US12 11-4TR00

1 unit 143

0.470

8US1211-4TR00

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/21

10

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Busbar adapters and device holders
For SIRIUS 3RV1/3RT1 load feeders
Busbar
device
adapters

Number Adapter
of mount- Length Width
ing rails
(35 mm)

mm

mm

Connecting cables

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

Cross- Rated Rated


section current voltage

mm2

PS*/
P. unit

PG

Weight
per PU
approx.

kg

Busbar device adapters with terminals (at top) for any arrangement of components
--

182

45

1.5... 4

25

690

8US12 50-5RM07

1 unit

143

0.174

8US12 505RM07
Device holders for lateral attachment to busbar device adapters
of the same length

10

8US19 501AM00

Device
holders

182

45

--

--

--

8US12 50-5AM00

1 unit

143

0.158

Device
holders

182

55

--

--

--

8US12 60-5AM00

1 unit

143

0.202

Device
holders

--

242

54

--

--

--

8US12 60-5AP00

1 unit

143

0.243

--

--

--

--

--

8US19 98-1AA00

100 100 units

143

0.100

Connecting -wedges
(2 units
needed for
attachment)

Connecting
wedge
Side modules for extending busbar device adapters and device
holders of the same length
Side
modules

--

182

13.5

--

--

--

8US19 98-2BM00

4 units

143

0.036

Side
modules

--

200

--

--

--

8US19 98-2BJ10

1 unit

143

0.023

8US19 982BM00

* You can order this quantity or a multiple thereof.

10/22

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Connector for 3NP1 fuse switch disconnectors

Selection and ordering data


For snap connections to 60-mm-busbar systems
Rated current Iu

LV HRC fuse links


acc. to IEC 60269-1

Size

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

For cover level 32 / 70 mm,


with reach-around protection for 8US busbar system
Basic units
Flat terminals
160

00 / 000

3NP1 133-1BC10

1 unit

143

0.980

250

1 and 0

3NP1 143-1BC10

1 unit

143

2.850

400

2 and 1

3NP1 153-1BC10

1 unit

143

4.760

630

3 and 2

3NP1 163-1BC10

1 unit

143

6.840

160

000

3NP1 123-1BC20

1 unit

143

0.820

160

00 / 000

3NP1 133-1BC20

1 unit

143

0.980

250

1 and 0

3NP1 143-1BC20

1 unit

143

2.850

400

2 and 1

3NP1 153-1BC20

1 unit

143

4.990

630

3 and 2

3NP1 163-1BC20

1 unit

143

7.040

Box terminals
3NP1 133-1BC20

With electromechanical MFM fuse monitoring


Flat terminals
160

00 / 000

3NP1 133-1BC11

1 unit

143

1.420

250

1 and 0

3NP1 143-1BC11

1 unit

143

3.290

400

2 and 1

3NP1 153-1BC11

1 unit

143

5.200

630

3 and 2

3NP1 163-1BC11

1 unit

143

7.280

Box terminals
3NP1 133-1BC21

160

00 / 000

3NP1 133-1BC21

1 unit

143

1.420

250

1 and 0

3NP1 143-1BC21

1 unit

143

3.290

400

2 and 1

3NP1 153-1BC21

1 unit

143

5.430

630

3 and 2

3NP1 163-1BC21

1 unit

143

7.480

With electronic EFM 10 fuse monitoring


Flat terminals
160

00 / 000

3NP1 133-1BC12

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC12

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC12

1 unit

143

4.900

630

3 and 2

3NP1 163-1BC12

1 unit

143

6.980

160

000

3NP1 123-1BC22

1 unit

143

0.940

160

00 / 000

3NP1 133-1BC22

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC22

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC22

1 unit

143

5.130

630

3 and 2

3NP1 163-1BC22

1 unit

143

7.180

Box terminals
3NP1 133-1BC22

With electronic EFM 20 fuse monitoring and


line monitoring
Flat terminals
160

00 / 000

3NP1 133-1BC13

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC13

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC13

1 unit

143

4.900

630

3 and 2

3NP1 163-1BC13

1 unit

143

6.980

160

000

3NP1 123-1BC23

1 unit

143

0.940

160

00 / 000

3NP1 133-1BC23

1 unit

143

1.120

250

1 and 0

3NP1 143-1BC23

1 unit

143

2.990

400

2 and 1

3NP1 153-1BC23

1 unit

143

5.130

630

3 and 2

3NP1 163-1BC23

1 unit

143

7.180

3NP1 933-1BC00

1 unit

143

0.145

Box terminals
3NP1 133-1BC23

Accessories
Connection modules
For 32-mm-cover level with
box terminal 6 mm ... 70 mm2

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/23

10

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Accessories

Selection and ordering data


The accessories are designed for the 8US 60-mm busbar system for Cu busbars according to DIN 46433, width 12 mm to
30 mm, thickness 5 mm and 10 mm, and special profiles up to
1600 A.
For SIRIUS 3RV2/3RT2 load feeders
Description

Length

Width

mm

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Busbar connection pieces

8US19 21-2BE00 /
8US19 21-2BF00

20 mm 5 mm,
20 mm 10 mm,
25 mm 5 mm,
25 mm 10 mm,
30 mm 5 mm,
30 mm 10 mm

40

8US19 21-2BE00

6 units

143

0.070

12 mm 5 mm,
12 mm 10 mm,
15 mm 5 mm,
15 mm 10 mm,
20 mm 5 mm,
20 mm 10 mm

55

8US19 21-2BF00

1 12 units

143

0.070

45

8US19 98-7CB45

1 10 units

143

0.009

54

8US19 98-7CB54

1 10 units

143

0.100

72

8US19 98-7CB72

1 10 units

143

0.100

8US19 98-1AA10

1 50 units

143

0.183

8US19 98-1BA10

1 10 units

143

0.183

8US19 98-1CA10

143

0.183

Mounting rails (35 mm) plastic


with fixing screws

10
8US19 98-7CB45

8US19 98-7CB54

8US19 98-7CB72
Connecting elements
For connecting busbar adapters
and device holders
8US19 98-1AA10
Spacers
Fixes the feeder to the busbar
adapter

8US19 98-1AA1
Vibration & shock kit
1 unit

* You can order this quantity or a multiple thereof.

10/24

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
60 mm Busbar Systems
Accessories
For SIRIUS 3RV1/3RT1 load feeders
Description

Length

Width

mm

mm

DT

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Busbar connection pieces

8US19 21-2BE00 /
8US19 21-2BF00

20 mm 5 mm,
20 mm 10 mm,
25 mm 5 mm,
25 mm 10 mm,
30 mm 5 mm,
30 mm 10 mm

40

8US19 21-2BE00

6 units

143

0.070

12 mm 5 mm,
12 mm 10 mm,
15 mm 5 mm,
15 mm 10 mm,
20 mm 5 mm,
20 mm 10 mm

55

8US19 21-2BF00

12 units

143

0.070

Mounting rails (35 mm) plastic


with fixing screws
45

8US19 98-7CA15

10 units

143

0.009

55

8US19 98-7CA16

10 units

143

0.100

72

8US19 98-4AA00

10 units

143

0.143

90

8US19 98-7CA08

10 units

143

0.187

110

8US19 98-7CA10

10 units

143

0.219

For fixing the motor starter protector to the mounting rail A


(for SIRIUS size S00/S0)

8US19 98-1DA00

100

20 units

143

0.100

8US19 98-1CA00

100

20 units

143

0.100

8US19 98-1BA00

100 100 units

143

0.100

8US19 98-1AA00

100 100 units

143

0.100

Mounting rail
Connection holders

NSE0_0347

8US19 98-1DA00
Screw holders
For supplementary screw mounting of the feeder
(for SIRIUS size S00/S0)
8US19 98-1CA00
Spacers
Fixes the feeder to the busbar adapter
(for SIRIUS size S00/S0)

8US19 98-1BA00
Connecting wedges
For mechanical linking of busbar device adapters and
device holder (2 units per combination)
Connecting wedge

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/25

10

Siemens AG 2011

Busbar Systems
Distribution board components

Overview
Material properties

Ambient temperatures

Busbar supports and busbar-mounting fuse bases (see "Built-in


components" from page 10/28) are manufactured from glass-fiber reinforced, thermoplastic polyester (color RAL 7035, light
gray). The material ensures excellent mechanical, chemical and
electrical properties. Furthermore, the material has an extremely
low flammability and meets the requirements of UL 94 V0. This
satisfies the load requirements of the busbar supports at rated
operational voltage 500 V and rated currents at 200 A to 630 A,
as well as the rated short-circuit strength 50 kA.

When dimensioning the busbars based on rated currents, the


ambient temperature and the Cu busbar temperature must also
be taken into account.
The location of the busbar system and its ability to dissipate heat
through convection also play a key role in this calculation. Because conditions can vary for each distribution board, the values
in the following table serve as a guideline only. However, they
must be applied to the entire busbar length.

Continuous currents depending on the Cu busbar dimensions and Cu busbar temperatures


at 35C ambient temperature
Cu busbar dimensions
HD

Uninterrupted current for open busbar routing


ambient temperature 35 C

Continuous current of fuse link


Operational class gL/gG

mm mm

12 5
12 10

200
360

200
315

15 5
15 10

250
447

250
400

20 5
20 10

320
520

315
500

25 5
25 10

400
580

400
500

30 5
30 10

447
630

400
630

As far as other types of upstream protective devices are concerned, please observe the permissible continuous current of the busbar.

10

Dynamic rated short-circuit strength


The electrodynamic load of the busbars depends on the level of
short-circuit current, the length of the busbar section through
which the current flows, the support spacing of the busbar supports and, of course, on the distance between the busbars themselves. This is because, for example, if an LV HRC fuse is connected upstream to the busbars in the protective device, the letthrough current iD is the maximum current to flow through this
protective device. The value iD depends on the maximum system short-circuit current and the current-limiting action of the
protective device used. The permissible let-through values of
the protective equipment are specified by the manufacturers in
the form of a current limitation diagram as a function of the socalled prospective short-circuit current (r.m.s. value of the possible rated short-circuit current for the system).

Diagram of the dynamic short-circuit strength of the busbars


I2_07483a

80
D

[kA]
70

It is essential to ensure that the permissible current carrying capacity of the individual busbars is not exceeded. A center infeed
is required in the limit range. However, the infeed can also be
carried out at both ends of the busbar.

10/26

Siemens LV 10.1 2011

630 A

500 A

60
30x10

Busbar dimension
mm
50
30x5

The current-limiting characteristics for the fuse links can be


found in the Technical Information, see note on Technical Information at the beginning of the chapter.
For busbar supports with busbars of 12 mm x 5 mm to
20 mm x 5 mm, the distance between the holders of the support
spacing should be adapted to suit the bars in the distribution
board and, if possible, should not exceed 250 mm. When using
busbars of 25 mm x 5 mm, 30 mm x 5 mm, 12 mm x 10 mm to
30 mm x 10 mm the distance can also be up to 500 mm. In the
case of larger distances, subcarriers must be fitted, as increased support spacing reduces the dynamic stability.

Let-through current
of the fuse links
Operating class
gL/gG

20x10
12x10

40

400 A

315 A

250 A

200 A

20x5
12x5
30
150

200

250

300

350

400

450

500

550

Distance between busbar support in mm

iD: Let-through values (kA) of the LV HRC fuse links, operational class
gL/gG with rated current 200 A to 630 A for a prospective short-circuit
current Ip = 120 kA.

Siemens AG 2011

Busbar Systems
Distribution board components
Planning dimensions
Width
mm

MW

NEOZED bus-mounting bases D02


Covers
Covers, extra wide
Covers, double width

27
36
54

1.5
2.0
3.0

DIAZED bus-mounting bases DII


Covers
Covers, double width

42
84

2.3
4.7

DIAZED bus-mounting bases DIII


Covers
Covers, double width

57
114

3.2
6.3

NEOZED bus-mounting switch disconnectors

27

1.5

LV HRC fuse switch disconnectors size 00

108

Number of built-in components that can be mounted


Height

Width

Cutout width

D02/63 A
5SH5 241

D02/63 A
5SH5 242

D02/63 A
5SH5 243

DII/25 A
5SH2 042

DIII/63 A
5SH2 242

5SG7 230 busmounting switch


disconnectors D02

mm

mm

mm

(27 mm width)

(36 mm width)

(54 mm width)

(42 mm width)

(57 mm width)

(26.8 mm width)

300

250
500

216
466

8
17

6
12

4
8

5
11

3
8

8
17

750

716

26

19

13

17

12

26

250
500

216
466

8
17

6
12

4
8

5
11

3
8

8
17

750

715

26

19

13

17

12

26

450

10

Dimensional drawings
8GK9 busbar support

N/PE busbar support

34

SECTION: A-A

30,5

15

194
200

60
191

I2_13999a

50

I2_14000a

NSE0_01568a

65

60

6,5

4 Nm

A
20

60

49,5
36,5
33

20

60

Connection modules

49,5

20

28

5SH3 540

5SH5 538

Connection modules

Connection modules

Connection modules

200

84

20
55
70

8US19 21-1AA00
shown closed

80
84

8US19 21-1AA00
shown opened

31
46
55

I2_06439b

I2_07150a

60

60

194

60

60
200

175

189
200

32

94

8GK9 711-0KK03

NSE0_01598

54

32

8US19 21-1BA00

Siemens LV 10.1 2011

10/27

Siemens AG 2011

Busbar Systems
Built-in components

Overview
Rail-adaptable built-in components, such as NEOZED and
DIAZED bus-mounting bases, adapters for modular installation
devices, LV HRC fuse switch disconnectors and NEOZED busmounting fuse switch disconnectors are made of glass-fiber reinforced, thermoplastic polyester. The material ensures the required mechanical, chemical and electrical properties.

have integrated reach-through guards, enable the implementation of cost-effective overall solutions.

Efficient power distribution up to 630 A.


Users have several options for mounting the SR60 busbar
system:

Higher overall efficiency and cost savings in the plant engineering industry.

Previously two optional solutions were provided, which can now


be replaced using new technology: touch protection over base
and edges or touch protection over partitions.

The fuse holders for cylindrical fuses, size 10 x 38 and for


American fuses, Class CC, can be used in the international plant
engineering industry. In addition, Siemens offers a broad range
of UL-approved components for the design of switchgear
assembly according to UL 508 A.
For further information, see Chapter "BETA Devices according to
UL Standards" in Catalog LV 16 2009.

1. Mounting in distribution boards


The busbar supports are mounted on the longitudinal stays.
Once the built-in components are mounted and connected, the
touch protection cover (section cover) protects against accidental contact with live parts.
2. Installation in industrial control cabinets

Fuse holders are available with a connection module 16 mm


and screwless terminals; this offers users maximum safety and
comfort.

The demand for comprehensive touch protection has generated


new solutions: built-in components, such as busbar fuse bases

7
6
5
4

10
1

I201_13634

I2_13634a

1
2
3
4
5
6

NEOZED bus-mounting bases, 3-pole


DIAZED bus-mounting bases, 3-pole
SR60 bus-mounting fuse holders, 3-pole
NEOZED bus-mounting switch disconnectors, 3-pole

Connection modules, three-phase


Adapters for modular installation devices according
to DIN 43880
7 LV HRC fuse switch disconnectors

Benefits
The direct contact of the rail-adaptable switching and installation devices on the Cu busbars reduces distribution panels
and mounting times.
Compared to conventional installation, the transfer resistance
of the connections is drastically reduced. This prevents unnecessary temperature rise.

10/28

Siemens LV 10.1 2011

New in-built components with touch protection ensure comprehensive touch protection without the previously required
partitions.
International application due to UL-approved components.
Enhanced effectiveness and increased safety due to screwless terminals.

Siemens AG 2011

Busbar Systems
Built-in components

Technical specifications
NEOZED SR60
bus-mounting bases

DIAZED SR60
bus-mounting bases

5SG6 202
5SG6 206
5SG6 207

5SF6 014
5SF6 015
5SF6 018
5SF6 020

5SF6 214
5SF6 215
5SF6 218
5SF6 220

DII

DIII

500

690/600
63

D01

D02

IEC 60269-3/ VDE 0636-3

Standards
Rated voltage

V AC/DC

400/250

Rated frequency

Hz

50

Rated current

16 (with NEOZED 63
retaining springs)

25

Rated conditional short-circuit current

kA AC
kA DC

50
8

50
8

For fuse links with power losses per phase

2.5

Busbar center-to-center spacing

mm

60

60

3NW7 431

3NW7 431-0HG
3NW7 432-0HG

Standards

IEC 60269-2,
UL 512, CSA C22.2

UL 512, CSA C22.2

Approvals

U, CSA

UL, CSA

Sizes

10 38

Class CC

5.5

Rated frequency

Hz

50/60

Max. rated voltage Ue


IEC/EN
UL/CSA

V AC
V AC

690
600

-600

Max. rated operational current Ie


(When several devices are used next to each other, it is essential to comply with the
rated load factor acc. to EN 60 439-1, Table 1.)
IEC/EN
UL/CSA

A
A

32
30

-30

Utilization categories
IEC/EN

10

AC-22B (500 V)
AC-21B (690 V, 30 A)
Can only be used as fuse holder

UL/CSA
Rated conditional short-circuit current
(type-tested with fuse links, operational class gL/gG)
IEC/EN
UL/CSA

kA
kA

100 (400 V, 500 V, 690 V)


50 (600 V)

-200

For fuse links with power losses per phase

--

Screwless wire connections


IEC/EN
UL/CSA

mm2
AWG

Cu 1.5 6 (f)
16 10 (str)
5SG7 230

3NW7 430

Standards

IEC 60269-3, IEC 60269-2

IEC 60269-3, IEC 60269-2

Approvals

EN 60947-3, IEC 60947-3

EN 60947-3, IEC 60947-3

Sizes

D01

10 mm 38 mm

D02

Rated frequency

Hz

50/60

50/60

Rated voltage Ue

V AC
V DC

400
110

690
--

Rated insulation voltage Ui

800

800

Rated impulse withstand voltage Uimp

kV

Rated operational current Ie

631)

Up to 32

AC-23 A (400 V)
DC-21 B (48 V) 1 pole
DC-21 B (110 V) 2 poles

AC-20
DC-20

Cu 1.5 6 (re)
Cu 1.5 16 (f)
Cu 1.5 16 (f+AE)

Cu 1.5 6 (re)
Cu 1.5 16 (f)
Cu 1.5 16 (f+AE)

Signaling switches for the display of switching positions

1 CO

1 CO

Cable terminals

Bottom

Bottom

Utilization categories
(Type-tested with 3-poled, switchable version)
Box terminals for wire connection

mm2
mm2
mm2

Busbar thickness

mm

Through combination foot for 5, 10 mm

Rated conditional short-circuit current


(type-tested with fuse links, operational class gL/gG)

kA AC
kA DC

50
8

50
--

Permissible power loss of fuse links per phase


For standalone operation without lateral modules or for group operation with lateral
modules

5.5

1)

In the case of permanent load over 35 A, we recommend the use of


5SH5 526 lateral modules. Please observe EN 60 439-1, Table 1.

Siemens LV 10.1 2011

10/29

Siemens AG 2011

Busbar Systems
Built-in components

Selection and ordering data


Size

Rated current

Rated voltage

Mount- DT
ing
width

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

NEOZED SR60 bus-mounting bases with


touch protection, 3P
For 5/10 mm busbars
27 mm wide
D02

63

400

1.5

5SG6 206

4 units

016

0.175

400

5SG6 207

4 units

016

0.188

1.5

5SG6 202

1 4/104 units

016

0.141

D02
Extra wide, with clearance for wiring

1.5

5SH5 241

1 4/200 units

016

0.023

D02

5SH5 242

1 4/140 units

016

0.027

5SH5 243

1 4/120 units

016

0.039

2.3
3.2

B
B

5SF6 018
5SF6 218

1
1

4 units
4 units

016
016

0.301
0.402

2.3
3.2

B
B

5SF6 020
5SF6 220

1
1

4 units
4 units

016
016

0.291
0.392

36 mm wide
D02

63

NEOZED SR60 bus-mounting bases, 3P


Standard version
For 5/10 mm busbars
D02

63

400

NEOZED SR60 covers for standard version

10

With double width


For more clearance for wiring
D02

DIAZED SR60 bus-mounting bases with


touch protection, 3P
For 5/10 mm busbars
For use with DIAZED SR60 adapter rings
DII
25
500
DIII
63
500 V AC/DC (acc. to
DIN VDE 0636-3 also
690 V AC/600 V DC)

For use with DIAZED screw adapters


DII
25
500
DIII
63
500 V AC/DC (acc. to
DIN VDE 0636-3 also
690 V AC/600 V DC)

For NEOZED screw caps, adapter sleeves and fuse links, see chapter "Fuse Systems", NEOZED fuse systems.

* You can order this quantity or a multiple thereof.

10/30

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
Built-in components
Size

Rated current

Rated voltage

Mount- DT
ing
width

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

DIAZED SR60 bus-mounting bases, 3P


Standard version
For 5/10 mm busbars
For use with DIAZED adapter rings
DII
25
500
DIII
63
500 V AC/DC (acc. to
DIN VDE 0636-3 also
690 V AC/600 V DC)

2.3
3.2

B
B

5SF6 014
5SF6 214

1
1

2/52 units
2/52 units

016
016

0.220
0.301

2.3
3.2

B
B

5SF6 015
5SF6 215

1
1

2/52 units
2/52 units

016
016

0.210
0.288

2.3
3.2

B
B

5SH2 042
5SH2 242

2/120 units

016

0.051

2/120 units

016

0.056

2
4
6

C
C
C

5SH3 071
5SH3 072
5SH3 073

1 10/1500 units
1 10/1500 units
1 10/3000 units

016
016
016

0.005
0.003
0.005

10
16
20

C
C
C

5SH3 074
5SH3 075
5SH3 076

1 10/4000 units
1 10/5000 units
1 10/3000 units

016
016
016

0.001
0.001
0.003

2
4
6

C
C
C

5SH3 078
5SH3 080
5SH3 081

1
1
1

10 units
10 units
10 units

016
016
016

0.009
0.009
0.008

10
16
20

C
C
C

5SH3 082
5SH3 083
5SH3 084

1
1
1

10 units
10 units
10 units

016
016
016

0.008
0.007
0.006

25
35
50

C
C
C

5SH3 085
5SH3 086
5SH3 087

1 10/1000 units
1 10/3500 units
1 10/600 units

016
016
016

0.005
0.005
0.004

For use with DIAZED screw adapters


DII
25
500
DIII
63
500 V AC/DC (acc. to
DIN VDE 0636-3 also
690 V AC/600 V DC)
DIAZED SR60 covers for standard version
DII
DIII

DIAZED SR60 adapter rings


Only for DIAZED SR60 bus-mounting bases
DII

DIII

SR60 bus-mounting fuse holders, 3P


For 5/10 mm busbars
with screwless terminals
For cylindrical fuses, 10 38 mm U, s
-30
690

1.5

3NW7 431

1 unit

018

0.185

For UL fuses, class CC u, s


-30
600

1.5

3NW7 431-0HG

1 unit

018

0.186

For UL fuses, class CC u, s


with LED signal detectors
-30
600

1.5

3NW7 432-0HG

1 unit

018

0.188

1.5

5SG7 230

1/30 units

016

0.747

1.5

3NW7 430

1/40 units

018

0.756

NEOZED SR60 bus-mounting switch disconnectors, 3P


For 5/10 mm busbars
D02
63*
400
*from 35 A load use 5SH5 526 side module
Rail-mounting disconnector SR60, 3P
For cylindrical fuses 10 mm 38 mm
For 5/10 mm busbars
--

32

690

For DIAZED screw caps, screw adapters and fuse links, see chapter "Fuse Systems", DIAZED fuse systems.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

10/31

10

Siemens AG 2011

Busbar Systems
Built-in components
Version

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW
Auxiliary switches for signaling the switching
state for NEOZED bus-mounting switch
disconnectors and bus-mounting disconnectors (for cylindrical fuses)
1 CO

0.5

5SH5 525

1/50 units

016

0.007

0.5

5SH5 526

5/50 units

016

0.051

5SH5 527

1 10/100 units

016

0.001

3NH4 052

014

0.663

5SH5 525
Lateral modules
For greater heat dissipation for loads > 35 A with
NEOZED bus-mounting switch disconnectors

5SH5 526
Reducers
For NEOZED fuse links D01
In SR60 bus-mounting switch disconnectors
5SH5 527
SR60 LV HRC bus-mounting fuse bases, 3P
Size 00
For 5/10 mm busbars
With cover, connections at top
Terminals up to 70 mm2
Rated voltage 690 V AC
With saddle-type terminal

10

4 units

3NH4 052

* You can order this quantity or a multiple thereof.

10/32

Siemens LV 10.1 2011

Siemens AG 2011

Busbar Systems
Built-in components

Dimensional drawings
NEOZED SR60 bus-mounting bases
D02/63 A
(a = 27 mm, b = 50 mm)

D02/63 A
(a = 36 mm, b = 50 mm)

I2_13998

I2_07478a

60

60

177

169

189
194
200

60

60

D02/63 A
(a = 27 mm, t = busbar thickness)

32
35
43

23
33,5
55

28

5SG6 202 (t = 5 mm)

5SG6 206

b
5SG6 207

DIAZED SR60 bus-mounting bases


DII/25 A
(a = 42 mm)

DIII/63 A
(a = 57 mm)

DII/25 A
(a = 42 mm)

DIII/63 A
(a = 57 mm)

189
194
200

169

a
36
43,5
66

5SF6 014, 5SF6 015


(t = 5 mm)

I2_13998

I2_07496

I2_07497

60

60

60

169

169

60

60

60

10

t
36
43,5
66

5SF6 214, 5SF6 215


(t = 5 mm)

32
35
43
28

5SF6 018, 5SF6 020


(b = 70 mm)

b
5SF6 218, 5SF6 220
(b = 70 mm)

Siemens LV 10.1 2011

10/33

Siemens AG 2011

Busbar Systems
Built-in components
NEOZED SR60 covers

SR60 LV HRC bus-mounting fuse bases, 3P

D02/63 A

89
64
29
4

99

60

33

I2_07500

27

36

5SH5 241
1-fold

60

200

200
60

60

60

200

200

60

60

60

33

I2_07511

I2_07510

I2_07479a

54

5SH5 242
1.33-fold

5SH5 243
2-fold

DIAZED SR60 covers

3NH4 052

NEOZED SR60 bus-mounting switch disconnectors/


SR60 bus-mounting disconnectors

DII/25 A

DIII/63 A

19,2

27,5 31,5
I2_08543

I2_14008

57

42
5SH2 042 (1-fold: a = 42 mm)

200

I2_14009

5SH2 242 (1-fold: a = 57 mm)

SR60 bus-mounting fuse holders for cylindrical fuses


79
63
27,5

32

I2_14001

60

194
200

60

34

27

3NW7 431,
3NW7 431-0HG,
3NW7 432-0HG

10/34

60

60

60

200

200

60

60

60

10

Siemens LV 10.1 2011

26,8
5SG7 230
3NW7 430

100

11

Siemens AG 2011

Measuring Devices and


E-Counters

11/2
11/3

11/6
11/9
11/12

11/14
11/17
11/21
11/23
11/26
11/27
11/28
11/29
11/30
11/31

Introduction
Energy management systems
Measuring devices and E-counters
E-Counters
PAC1500 three-phase counters
PAC1500 single-phase counters
Expansion modules for E-counters N
Power Monitoring Devices
PAC3000 multimeters
PAC3000 multicounters
7KT1 391 LAN couplers
PAC3100, PAC3200 and PAC4200
power monitoring devices
PAC3100 power monitoring devices
PAC3200 power monitoring devices
PAC4200 power monitoring devices
PAC PROFIBUS DP expansion modules
PAC RS485 expansion modules
PAC 4DI/2DO expansion modules for
PAC4200 N

11/32

Analog Volt- and Ammeters


7KT1 0 measuring devices

11/33

Digital Volt- and Ammeters


7KT1 11, 7KT1 12 measuring devices

11/35
11/37

11/39
11/40

Time and Pulse Counters


Time and pulse counters for mounting
onto standard rail
Time counters for front-panel
mounting

11

Accessories
7KT1 2 current transformers
7KT9 0 measuring selector switches

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical Specifications
under Entry List:
- Updates
- Download
- FAQ
- Manuals
- Characteristic curves
- Certificates
and at
www.siemens.com/lowvoltage/configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Introduction
Energy management systems

Overview
System configuration
Operation & monitoring
Windows or web clients
Ethernet
Data processing
SENTRON powermanager server
Ethernet (Modbus)
Data detection
Measuring/protection devices

PAC3200

PAC4200

PAC3200

SENTRON
3WL

SENTRON
3VL

I202_01389

Modbus RS485
PAC3100

System overview

The SENTRON-based power management system is comprised


of a PC with the related power management software and with
the related devices which are connected directly to the PC
through Ethernet.
General goals of a power management system:
to identify savings potential
to reduce power costs
to ensure power availability

11

through transparency of the momentary conditions and through


comprehensive power assignments and evaluations.

SENTRON powermanager
The SENTRON powermanager power management software
is an independent power management software
can be operated with a PC and measuring instruments with
Ethernet connection
is expandable from the simple standard application to a fully
flexible customer solution
is fully scalable with regard to the number of devices and to
the software's functions
ensures the optimum integration of measuring instruments
from the SENTRON PAC range, SENTRON 3WL/3VL circuit
breakers and other devices
SENTRON powermanager is designed for:
collecting
monitoring
evaluating
presenting
archiving
power data from SENTRON PAC3100, PAC3200 and PAC4200
power monitoring devices, SENTRON 3WL/3VL circuit breakers,
and any Modbus-capable detecting devices.

Benefits

Transparency of power flows


Exact knowledge of the consumption profile
Increase of power efficiency
Optimization of power supply contracts
Compliance with contractual terms
Assignment of power costs to cost centers
Optimization of plant maintenance
Identification of critical plant conditions

The SENTRON product family includes not only a power management software in the form of SENTRON powermanager but
also the matching hardware in the form of the SENTRON PAC
and the SENTRON 3WL/3VL for realizing a complete power
management system.

The components are optimally coordinated with each other. For


example, special drivers for the SENTRON devices are integrated in the SENTRON powermanager software so that on the
one hand the power data acquisition can take place without any
great configuration effort and on the other hand the most important measured values or states are indicated by predefined displays. This reduces the amount of engineering work.
The SENTRON powermanager software comprises a server/client software for the acquisition, processing, presentation and archiving of power data. These power data are supplied primarily
by power monitoring devices (PAC) or 3WL/3VL circuit breakers
which are connected to the system through Ethernet.

More information
Hardware components of the Power Management System are
dealt with in this chapter, its software components in chapter 13.

11/2

Siemens LV 10.1 2011

You can find more information on the Internet at:


www.siemens.com/powermanagementsystem

Siemens AG 2011

Measuring Devices and E-Counters


Introduction
Measuring devices and E-counters

Page Application

Standards

Used in

Residential
buildings

Industry

Devices

Non-residential
buildings

Overview

11/6

EN 50470-1,
EN 50470-3

E-counters
PAC1500 three-phase counters
7KT1 5 E-counters

PAC1500 single-phase counters


7KT1 53, 7KT1 14 E-counters

Expansion modules

11/9

Measurement of consumption data and


plant capacity utilization in three-phase
systems of system components, offices
or holiday apartments.

EN 62052-23,
EN 62053-31

For the measurement of kWh in single- EN 50470-1, EN 50470-3,


phase systems, e.g. in industrial plants, EN 62053-31
offices and apartments in apartment
houses

11/12 Communication interfaces with IrDA


infraret interface for PAC1500 E-counters. Modules are available for the
following bus systems:

EN 13757
ISO/IEC 14543-3
EN 50090, EN 13321-1

11

M-Bus
Modbus RTU
KNX/EIB
RS 485

Multifunction measuring instruments


PAC3000 multimeters
7KT1 30

PAC3000 multicounters
7KT1 31, 7KT1 34

11/14 Display of 23 electrical measured values IEC 60051-2, EN 60051-2


for switchgear assemblies, infeed or
IEC 61010-1, EN 61010-1
outgoing feeders.
(VDE 0411 T 1)
Easy commissioning due to fault detection if connected incorrectly.

--

11/17 Display of 35 electrical measured values IEC 60051-2, EN 60051-2


and consumption values in switchgear IEC 61010-1, EN 61010-1
assemblies, infeed or outgoing units.
(VDE 0411 T 1)
Easy commissioning due to fault detec- IEC 62053-21,
tion if connected incorrectly.
EN 62053-21

--

--

(VDE 0418 T 3-21)

7KT1 391 LAN couplers

11/21 Up-to-date consumption data of multiIEEE 802


counters and E-counters available worldwide using LAN data communication.

Siemens LV 10.1 2011

11/3

Siemens AG 2011

Measuring Devices and E-Counters


Introduction
Measuring devices and E-counters

AC/DC power supply unit with


screw connection

11/26 Display of 30 electrical measured values IEC 61557-12


and consumption values in switchgear
assemblies, infeed or tap-off units.

Used in

Industry

PAC3100 power monitoring


devices

Standards

Residential
buildings

Page Application

Non-residential
buildings

Devices

--

--

--

International standards and multi-lingual


displays for worldwide use.
Control panel flush-mounting instrument
with graphics display, integrated digital
in- and outputs and a RS 485-interface
for the transfer of measured values and
configurations.

PAC3200 power monitoring


devices
3 versions:
AC/DC power supply unit with
screw connection
DC power supply unit with extralow voltage, screw connection
AC/DC power supply unit with
ring terminal lug connection

PAC4200 power monitoring


devices
2 versions:
AC/DC power supply unit with
screw connection

11

AC/DC power supply unit with


ring terminal lug connection

11/27 Display of over 50 electrical measured


Energy-measurement
values for switchgear assemblies, infeed accuracy according to
or outgoing feeders. 10 dual-tarif energy IEC 62053
counters for precise energy monitoring
for power draw and feedback.
International standards and multi-lingual
displays for worldwide use.
Control panel flush-mounting instrument
with graphics display, integrated digital
in- and outputs and an integrated
Ethernet interface for the transfer of
measured values and configurations.
Plug-in options module for Modbus RTU
or PROFIBUS DP.
11/28 Display of over 200 electrical measured IEC 61557-12
values for switchgear assemblies, infeed
or outgoing feeders. Extensive functions
for precise energy-monitoring for power
draw and feedback and for appraisal of
network quality.
International standards and multi-lingual
displays for worldwide use.
Control panel flush-mounting instrument
with graphics display, user-defined
displays, memory, clok and calendar
function, digital in- and outputs and an
integrated Ethernet interface with gateway function to transfer measured values
and configurations. Plug-in options module for Modbus RTU or PROFIBUS DP.

PAC PROFIBUS DP expansion


modules

11/29 The SENTRON PAC PROFIBUS DP


expansion module is used to connect
the PAC3200 and PAC4200 multifunction
measuring instruments to the RS 485.

--

PAC RS485 expansion modules

11/30 The SENTRON PAC PROFIBUS DP


expansion module is used to connect
the PAC3200 and PAC4200 multifunction
measuring instruments to the
PROFOBUS DP- V1..

--

--

PAC 4DI/2DO expansion modules 11/31 The SENTRON PAC 4DI/2DO expansion IEC 62053-31
module is used to expand the SENTRON
PAC4200 power monitoring device to up
to 10 digital inputs and 6 digital outputs.

11/4

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Introduction

Page

Application

Non-residential
buildings

Residential
buildings

Industry

Measuring devices and E-counters


Devices

Standards

Used in

11/32

Voltage and current measurement for


IEC 60051-2,
monitoring incoming and outgoing cur- EN 60051-2
rents as well as device currents in order
to prevent plant overload.

--

7KT1 11, 7KT1 12 measuring devices 11/33

Voltage and current measurement with DIN 43751-1,


large 3-digit LEDs for monitoring incom- DIN 43751-2
ing and outgoing currents as well as
device currents in order to prevent plant
overload.

--

For monitoring operating hours and


starting operations for planning preventative maintenance tasks and preventing sudden shutdowns

Analog measuring devices


7KT1 0 measuring devices

Digital measuring devices

Time and pulse counters


Time and pulse counters for mounting onto support rail

11/35

7KT5 8

IEC 60255-6,
EN 60255-6
(VDE 0435-301),
UL 94

11
Time counters for front-panel
mounting

11/37

For monitoring operating hours and


IEC 60255-6,
starting operations for planning preven- EN 60255-6
tative maintenance tasks and prevent- (VDE 0435-301)
ing sudden shutdowns.

11/39

Straight-through transformers for instal- IEC 60044-1,


lation in distribution boards and nonEN 60044-1
contact measuring of primary currents. (VDE 0414 T 44-1)

--

--

7KT5 5, 7KT5 6

Accessories
7KT1 2 current transformers

Ideal for combining with switch disconnectors, multimeters, multicounters and


E-counters.

7KT9 0 measuring selector switches

11/40

For switching over the phases for voltmeters and ammeters

Siemens LV 10.1 2011

11/5

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
PAC1500 three-phase counters

Overview
The E-counters (power meters) are used to record the amount of
electrical energy exported or imported. Siemens compact
E-counters are designed as modular devices for alternating
current and can be mounted on standard mounting rails. They
comply with the counter standard EN 50470 (Part 1 and 3) and
come with an LCD display.
Three-phases counters are available up to 80 A and in versions
with transformer connections (/5 A to 10000/5 A).
E-counters store both active and reactive energy, and comply
with accuracy class 1 (for active energy).
All E-counters have a pulse output (S0) and are designed for
2-tariff measurements. The calibrated versions are in
accordance with the Directive 2004/22/EC on measuring instruments.

3-phase counter PAC 1500 (7KT1 543) with direct connection up to 80 A

Benefits

11

Complies with the new counter standard EN 50470


(Part 1 and 3)
Easy-to-read LCD display
Versions calibrated in accordance with the Directive
2004/22/EC on measuring instruments can be used for
invoicing purposes
Exact recording thanks to accuracy class 1 (for active energy)
Direct connection up to 80 A;
Transformer current connection .../5 A
Sealable terminal covers

11/6

Siemens LV 10.1 2011

At the same time the E-counters have an integrated optical interface (IrDA) for connecting communication modules, which
enables their integration in a range of other systems, such as
energy management systems.

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
PAC1500 three-phase counters

Technical specifications
PAC1500 three-phase E-counters

7KT1 543
7KT1 545

7KT1 540

Standards

EN 50470-1, EN 50470-3,
EN 62053-23, EN 62053-31

Connection
Direct connection
Transformer current connection

-.../5 A

80 A
--

General data
Enclosure, mounting width
Mounting
Mounting height

Acc. to DIN 43880


Acc. to EN 60715

MW
mm

4
35 mm
70

Function
Operating mode
Storage of setting and counter reading
Tariff for active and reactive energy

Three-phase loads
Through (EEPROM)

Conductors

2-3-4
Yes
T1/T2

V AC
V
Hz
VA (W)

230
184 ... 276
50
 8 (0.6)

3-4

Supply (through measuring terminals)

Rated control supply voltage Un


Voltage range
Rated frequency fn
Rated power dissipation Pv

Overload capability
Voltage Umax

Current Imax

Continuous operation:
Phase/phase
1 second: Phase/phase
Continuous operation: Phase/N
1 second: Phase/N

480

V
V
V

800
276
300

Continuous operation
Short-time operation (for 0.5 s)
Short-time operation (for 10 ms)

A
A
A

80
-2400

120
--

Display (readout)
Connection error and phase failure

Display of rotating field error

PHASE Err

Display

LCD
Digit dimensions

Digits
mm x mm

8 (1 decimal point)
6x3

Active energy: 1 display, 8-digit


+ display import or export (arrow)

Tariff/tariffs
Max. display (continuous)

kWh
kWh

000000.0 ... 999999.9


999999.9 ... 000000.0

Reactive energy: 1 display, 8-digit


+ display import or export (arrow)

Tariff/tariffs
Max. display (continuous)

kvarh
kvarh

000000.0 ... 999999.9


999999.9 ... 000000.0

11

000 ... 999


W, kW, MW
var, kvar, Mvar 000 ... 999

Instantaneous active power: 1 display, 3-digit


Instantaneous reactive power: 1 display, 3-digit

T1/T2
-2

Display tariff identification


Transformer primary current
Display period

1 display, 1-digit

Measuring accuracy

At 23 1 C based on nominal value

Active energy and active power


Reactive energy and reactive power

Acc. to EN 50470-3
Acc. to EN 62053-23

%
%

1 (B)
2

Phase/phase
Phase/N

V
V

Direct
400
230

Phase/phase
Phase/N

V
V

319 ... 480


184 ... 276

A
A
A

15
-0.75

-5
0.05

A
A

0.0025 ... 80
--

-0.010 ... 6

---

5 ... 10000
5

50
Symmetrical sinusoidal
25

10

5 ... 10000
2

Measuring inputs
Connection type
Voltage Un
Operating range voltage
Current Iref
Current In
Current Imin
Operating range current (Ist Imax)

Direct connection
Transformer connection

Transformer current

Primary current of the transformer A


Smallest input step
A

Frequency
Input ripple form
Operational starting current Ist
S0 interface

Hz
mA
Acc. to EN 62053-31

Pulse outputs
- For absorbed active and reactive energy T1 + T2

Yes
kWh
kWh
ms

-500
-30 5 ms

Required voltage

V AC
V DC

5 ... 230 5 %
5 ... 300

Permissible current
Permitted current

mA
A

90
1

Pulse quantity
- At 80 A
- Can be set on transformer
Pulse duration

Transformer TA-TC .../5 A

-1000 - 10 - 1

Siemens LV 10.1 2011

11/7

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
PAC1500 three-phase counters
PAC1500 three-phase E-counters

7KT1 543
7KT1 545

7KT1 540

1000

10000

Optical interfaces
Calibration from the front (accuracy check)

LED

kWh

IR interface
At the side for connecting communication modules
(M-Bus / Modbus RTU / RS 485 / KNX)

Yes
Acc. to EN 50470-1

Safety
For indoor areas
Overvoltage category
Operational voltage

Yes
4
300

kV
Class

6
V0
Yes

Pozidriv
mm x mm

PZ2
0.8 x 3.5

PZ1
0.8 x 3.5

Conductor cross-sections of operational current and


main current paths
- Rigid
- Flexible, with end sleeve

mm2
mm2

1.5 ... 35
1.5 ... 35

1.5 ... 6
1.5 ... 6

Conductor cross-sections for S0 pulse outputs


- Rigid
- Flexible, with end sleeve

mm2
mm2

0.14 ... 2.5


0.14 ... 1.5

0.14 ... 2.5


0.14 ... 1.5

Test voltage
1.2/50 s
Flame resistance
UL 94
Seal between the top and bottom of the enclosure (mod. 7KT1 543)
Terminal connections
Lift terminals of main current paths
Lift terminals for S0 pulse outputs

Screw head Z
Blade for slotted screw

Ambient conditions
Mechanical environment
Electromagnetic environment

M1
E2

Operating temperature
Temperature limits for storage and transport
Relative humidity (without condensation)
Vibrations
Degree of protection
1)

11

Sinus amplitude at 50 Hz
Installed device
Front side/terminals

C
C

-10 ... +55


-25 ... +70

%
mm

 80
0.075
IP511)/IP20

For installation in a distribution board with at least IP51 degree of protection.

Selection and ordering data


Un

Imax

Mount- DT
ing
width

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.

V AC

A AC

MW

For direct connection, double rate


230

80

7KT1 543

1 unit

027

0.386

For direct connection, double rate,


calibrated version
230

80

7KT1 545

1 unit

027

0.395

7KT1 540

1 unit

027

0.281

kg

PAC1500 three-phase counters


Digital E-counter

For transformer connection, double rate


230
transformer /5

* You can order this quantity or a multiple thereof.

11/8

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
PAC1500 single-phase counters

Overview

Benefits
Digital 7KT1 53 E-counter.
Complies with the new counter standard EN 50470
(Part 1 and 3)
Easy-to-read LCD display
Versions calibrated in accordance with the Directive
2004/22/EC on measuring instruments can be used for
invoicing purposes
Exact recording thanks to accuracy class 1 (for active
energy).
E-counters for active energy 7KT1 140
The drum-type register with digit size 4 mm 1.2 mm enables
easy reading
The short-circuit proof pulse output protects the device if it is
assembled incorrectly.
Direct connection up to 80 A

PAC1500 single-phase E-counters:


left: Digital 7KT1 53 E-counter
right: 7KT1 140 E-counters for active energy

The E-counters (power meters) are used to record the amount of


electrical energy exported or imported. Siemens compact
E-counters are designed as modular devices for alternating current and can be mounted on standard mounting rails. They comply with the counter standard EN 50470 (Part 1 and 3) and come
with an LCD display.
The PAC1500 single phase counters for direct connection are
available up to 80 A. They store both active and reactive energy
and all comply with accuracy class 1 (for active energy).
All E-counters have a pulse output (S0) and are designed for
1-tariff or 2-tariff measurements depending on the version. The
calibrated versions are in accordance with the Directive
2004/22/EC on measuring instruments.

11

At the same time the E-counters


except version 7KT1 140

have an integrated optical interface (IrDA) for connecting communication modules. Integration of the E-counters, e.g. in energy management systems, is thus possible.

Technical specifications
PAC1500 single-phase counters,
direct connection up to 80 A

7KT1 530

7KT1 531
7KT1 533

7KT1 140

Standards

EN 50470-1, EN 50470-3, EN 62053-23, EN 62053-31

General data
Enclosures

Acc. to DIN 43880

Mounting

Acc. to EN 60715

Mounting height

MW

2
35 mm

mm

70

Conductors

Function
Operating mode

Single-phase loads

Storage of setting and counter reading

Through (EEPROM)

Yes

Rate

For active energy

T1

T1 + T2

T1

For reactive energy

T1

T1 + T2

--

--

Supply (through measuring terminals)


Rated control supply voltage Un

V AC

230

Voltage range

184 ... 276

Rated frequency fn

Hz

50

Rated power dissipation Pv

VA (W)

 8 (0.6)

Continuous operation

276

Short-time operation (for 1 s)

300

Continuous operation

80

Overload capability
Voltage Umax
Current Imax

Short-time operation (for 10 ms) A

2400

Siemens LV 10.1 2011

11/9

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
PAC1500 single-phase counters
PAC1500 single-phase counters,
direct connection up to 80 A

7KT1 530

7KT1 531
7KT1 533

7KT1 140

Display
Display mode

LCD

Digits

7 (1 decimal point)

Electromechanical

mm x mm

6x3

Active energy: 1 display, 7-digit


+ display import or export (arrow)

Tariff/tariffs
Max display (continuous)

kWh
kWh

000000.0 ... 999999.9


999999.9 ... 000000.0

Reactive energy: 1 display, 7-digit


+ display import or export (arrow)

Tariff/tariffs
Max display (continuous)

kvarh
kvarh

000000.0 ... 999999.9


999999.9 ... 000000.0

Instantaneous active power: 1 display, 3-digit

W, kW, MW

000 ... 999

Instantaneous reactive power: 1 display, 3-digit

var, kvar,
Mvar

000 ... 999

Display dimensions

3.8 x 1.5

---

--

Current tariff
1 display, 1-digit
Display period
Measuring accuracy at 23 1 C

T1

T1/T2

T1

--

Based on nominal value

Active energy and active power

Acc. to EN 50470-3

1 (B)

Reactive energy and reactive power

Acc. to EN 62053-23

--

Measuring inputs
Connection type

Phase/N

Operating range voltage

Phase/N

Current Iref
Current Imin
Operating range current (Ist ... Imax)

Direct connection

Frequency

Direct
V AC

184 ... 276

15

0.75

0.0025 ... 80

Hz

50

Current waveform

Symmetrical sinusoidal
mA

Operational starting current Ist


Pulse outputs
- For absorbed active and reactive energy

11

25

Acc. to EN 62053-31

S0 interface

Yes

Pulse count

Pulses/kWh

1000

Pulse duration

ms

30 5

Required voltage

V AC
V DC

5 ... 230 5 %
5 ... 300

Permissible current (pulse on)

mA

90

Permissible current (pulse off, maximum fault current)

Pulses/kWh

1000

Yes, only for


active energy
30 2

Optical interfaces
Calibration from the front (accuracy check)

LED

IR interface
At the side for connecting communication modules
(M-Bus / Modbus RTU / RS 485 / KNX)

--

Acc. to EN 50470-1

Safety
For indoor areas

Yes
4

Overvoltage category
Operational voltage

300

Test voltage

1.2/50 s

kV

Flame resistance

UL 94

Class

V0

Terminal connections
Lift terminals of main current paths

Screw head Z Pozidriv

Lift terminals for S0 pulse outputs

Blade for slotted screw

PZ2
mm x mm

0.8 x 3.5

Conductor cross-sections of operational current Rigid


and main current paths
Flexible, with end sleeve

mm2
mm2

1.5 ... 35
1.5 ... 35

Conductor cross-sections for S0 pulse outputs

mm2
mm2

0.14 ... 2.5


0.14 ... 2.5

Rigid
Flexible, with end sleeve

Ambient conditions
Mechanical environment

M1
E2

Electromagnetic environment
Operating temperature

-10 ... +55

Temperature limits for storage and transport

-25 ... +70

Relative humidity (without condensation)

 80

mm

0.075

Vibrations

Sinus amplitude at 50 Hz

Degree of protection

Installed device
Front side/terminals

1)

For installation in a distribution board with at least IP51 degree of


protection.

11/10

Siemens LV 10.1 2011

IP511)/IP20

Yes

--

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
PAC1500 single-phase counters

Selection and ordering data


Un

Imax

Mount- DT
ing
width

V AC

A AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

PAC1500 single-phase counters


Digital E-counter
For direct connection, single rate
230
80

7KT1 530

1 unit

027

0.164

For direct connection, double rate


230
80

7KT1 531

1 unit

027

0.164

For direct connection, double rate,


calibrated version
230
80

7KT1 533

1 unit

027

0.190

7KT1 140

1 unit

027

0.141

PAC1500 single-phase counters for active energy


Digital E-counter,
with 7-digit drum-type register 4 mm 1.2 mm
with S0 interface, for single-phase operation
Direct connection, single rate
230

80

11

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/11

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters
Expansion modules for E-counters

Overview

N
Expansion module versions
7KT1 908 (M-Bus communication module)
Power supply through bus cable
Baud rates: 300 to 9600 kbit/s
Status indication by LED on the module
Can be parameterized using M-Bus Master software
7KT1 907 (Modbus RTU communication module)
Power supply: 230 V AC
Baud rates: 4.8 / 9.6 / 19.2 and 38.4 kbit/s are supported.
Status indication by LED on the module
Can be parameterized using RS-485 Master software
7KT1 900 (KNX/EIB communication module)
Power supply through the KNX/EIB bus cable
Status indication by LED on the module

Expansion module for Instabus KNX (left) with

3-phase counter PAC 1500 (7KT1 543, right)

Expansion modules are used as communication interfaces for


PAC1500 E-counters. They have the following features:
The expansion modules can be selected independently of the
E-counter. Retrofitting of already installed E-counters is therefore possible if required.
Data transmission between the E-counters and the expansion
modules takes place through the IrDA infrared interface.
The expansion modules are placed alongside the E-counters
in the installation direction so that their IrDA interfaces lie exactly opposite.

11

11/12

Siemens LV 10.1 2011

7KT1 903 (RS-485 communication module)


Power supply: 230 V AC
Status indication by LED on the module

Siemens AG 2011

Measuring Devices and E-Counters


E-Counters

Expansion modules for E-counters

Selection and ordering data


Version

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW
Expansion module M-Bus

7KT1 908

1 unit

027

0.050

7KT1 907

1 unit

027

0.050

7KT1 903

1 unit

027

0.050

7KT1 900

1 unit

027

0.050

For connecting PAC1500 E-counters to


M-Bus

7KT1 908

Expansion module Modbus RTU


For connecting PAC1500 E-counters to
RTU Modbus

7KT1 907

Expansion module RS 485


For connecting PAC1500 E-counters via
RS 485 to LAN coupler 7KT1 391

7KT1 903

Expansion module KNX

11

For connecting PAC1500 E-counters to


Instabus KNX

7KT1 900

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/13

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multimeters

Overview

Benefits
Clear display of all necessary measured values
All measured values can be read from a distance
Customized setting of the measured quantities for the standard display
Wide range of application thanks to flexible adaptation to
measuring current transformers
Detection of connection errors during commissioning saves
considerable time when trying to locate faults
Large, 11 mm high, green 7-segment displays for measured
values makes for easy reading
Indication of units of measurement directly alongside the related measured values provide a clear overview.

PAC3000 multimeters

Multimeters are mainly used in power distribution boards for infeeds into buildings and plants. They replace the more common
analog voltmeters and ammeters with measuring point changeover, as well as measuring devices for power outputs and power
factor p.f..
The standard measured quantity to be indicated in the 5 display
fields of the multimeter can be tailored to customer requirements. Versions for direct connection (63 A) or for transformers
(/5 A) with adjustable transformer primary current from 5 A to
5000 A, enable a wide range of application.

11

The green 7-segment displays for the measured values and the
orange indicators of the units of measurement directly alongside
the measured values make for easy reading.

Technical specifications
PAC3000 multimeters

7KT1 300

Standards

DIN 43751-1, DIN 43751-2 and EN 61010-1

7KT1 301

Supply
Rated control supply voltage Uc

V AC

230

Primary operating range

Uc

0.8 ... 1.2

Rated frequency

Hz

50

Frequency ranges

Hz

45 ... 65

Rated power dissipation Pv

VA

 10

Continuous: Phase/phase
1 second: Phase/phase

V
V

480
800

Continuous: Phase/N
1 second: Phase/N

V
V

276
460

Continuous
0.5 s
10 ms

A
A
A

76
-1000

6
110
--

Direct

Transformer /5 A

Voltage Ue

Phase/phase
Phase/N

V
V

400
230

Operating range voltage

Phase/phase
Phase/N

V
V

87 ... 400
50 ... 230

Current Ie

63

Operating range current

0.1 ... 63

0.01 ... 5

A
A

---

5 ... 5000
5

Frequency

Hz

50

Frequency ranges

Hz

45 ... 65

Overload capability
Voltage

Current

Measuring inputs
Connection type

Transformer current

11/14

Siemens LV 10.1 2011

Primary current of the transformer


Smallest input step

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multimeters
PAC3000 multimeters

7KT1 300

7KT1 301

Display
Connection errors

Inverted phases

Voltage: 3 displays, 3-digit

Delta L1 L2, L2 L3, L3 L1


Star L1/N L2/N L3/N
Voltage > 480/276 V
Voltage < 87/50 V

Current: 3 displays, 3-digit

L1 L2 L3
For current > 76 A or 6 A transformer
conversion ratio
For current < 0.1 A or 0.01 A transformer
conversion ratio

Err
V
V

87 ... 480
50 ... 276
HHH

0.3 ... 76 A
HHH

0.1 A ... 1.2 kA

OOO

Frequency: 1 display, 3-digit

Hz

45.0 ... 65.0

Active power: 3 displays, 3-digit or


1 display, 3 of 7 digits

L1 L2 L3, L
display with floating decimal point

W, kW
or MW

0 ... 999

Reactive power: 1 display, 3-digit

L, with capacitive or inductive indication;


display with floating decimal point

var, kvar
or Mvar

0 ... 999

Apparent power: 3 displays, 3-digit or


1 display, 3-digit

L1 L2 L3, L
display with floating decimal point

W, kW
or MW

0 ... 999

p.f.: 3 displays, 3-digit or 1 display, 3-digit L1 L2 L3, L


display with floating decimal point

0.01 ... 1.00

Transformer primary current

Only if set

--

5 ... 5000

Transformer secondary current

Only if set

--

/s

Display period

EEPROM

Storage of setting
Measuring accuracy
Voltage

Current

Power

P.f.

Frequency

Safety according to EN 61010-1


Pollution degree

2
II

Overvoltage category
Operating voltage category

600

Clearances

mm

 3.0

In device
On printed boards (not installed)

mm
mm

 4.3
 3.0

Test pulse voltage

1.2/50 s

kV

Test voltage

50 Hz, 1 min

kV

2.2

Creepage distances

11

Terminals
Main current paths

screw (Pozidriv)

Supply terminals

Blade for slotted screw

mm mm

2
0.4 2.5

Conductor cross-sections, main current


paths

Rigid, maximum

mm2

1 25 or 2 16

Rigid, minimum

mm2

1 1.5

Conductor cross-sections for supply


terminals

Rigid, maximum

mm2

1 2.5 or
2 1.5

Flexible, with end sleeve, minimum

mm2

1 0.75

Temperatures

0 ... +55

Relative humidity

 80

mm

0.25

1
1 6 or
24

Ambient conditions

Vibrations

Sinus amplitude at 50 Hz

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Safety class

Acc. to EN 61010-1

II

Siemens LV 10.1 2011

11/15

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multimeters

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

PAC3000 multimeters
For the display of 23 electrical values,
of which 5 values can be continuously displayed,
mounting onto standard rail
For direct connection
3 230/400 63

230

7KT1 300

1 unit

027

0.465

7KT1 301

1 unit

027

0.407

For transformer connection 5 ... 5000 A,


adjustable in 5 A steps, secondary current 5 A
3 230/400 transformer /5

230

7KT1 300

More information
Readout data
You can continuously display 5 measured quantities from the following 23 options.

11

No.

Measured value

Display

Unit

Assignment

Active power

D1

L1

Voltage

D1

L1

Current

D1

L1

Apparent power

D1

VA

L1

P.f.

D1

P.f.

L1

Voltage

D1

L1 L2

Active power

D2

L2

Voltage

D2

L2

Current

D2

L2

10

Apparent power

D2

VA

L2

11

P.f.

D2

P.f.

L2

12

Voltage

D2

L2 L3

13

Active power

D3

L3

14

Voltage

D3

L3

15

Current

D3

L3

16

Apparent power

D3

VA

L3

17

P.f.

D3

P.f.

L3

18

Voltage

D3

L3 L1

19

Active power

D1, D2, D3, D5

20

Apparent power

D1, D2, D3, D5

VA

21

Reactive power

D5

var

22

Frequency

D4

Hz

23

P.f.

D1, D2, D3, D4

P.f.

D5

CT/A

/5

CT/A

5 ... 5000

2 set values are also indicated:


24

Transformer setting

25

Transformer setting

* You can order this quantity or a multiple thereof.

11/16

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multicounters

Overview

Benefits
Clear display of all necessary measured values
All measured values can be read from a distance
Customized setting of the measured quantities for the standard display. Fast display of all measured quantities over operator buttons
Wide range of application thanks to flexible adaptation to
measuring current transformers
Detection of incorrect connections during installation
Communication with LAN or Modbus RTU enables integration
in an energy management system

Multicounter PAC3000
Multicounters are mainly used in power distribution boards for infeeds into buildings and plants. They replace the more common
analog voltmeters and ammeters with measuring point changeover, as well as measuring devices for power outputs and power
factor p.f..
The standard measured quantity to be indicated in the 6 display
fields of the PAC3000 multicounter can be tailored to customer
requirements. The measured values of all measured quantities
can also be displayed quickly and easily over the operator buttons. Versions for direct connection (63 A) or for transformers
(/5 A) with adjustable transformer primary current from 5 to
5000 A, enable a wide range of application.

11

The green 7-segment displays for the measured values and the
orange indicators of the units of measurement directly alongside
the measured values make for easy reading.

Technical specifications
PAC3000 multicounters without communication interface

7KT1 310

7KT1 311

PAC3000 multicounters with RS 485 interface (Modbus RTU, for LAN couplers)

7KT1 340

7KT1 341

Standards

EN 61010-1, EN 62053-21, -23, -31

Supply
Rated control supply voltage Uc

V AC

230

Primary operating range

Uc

0.8 ... 1.2

Rated frequency

Hz

50

Frequency ranges

Hz

45 ... 65

Rated power dissipation Pv

VA

 10

Continuous: Phase/phase
1 second: Phase/phase

V
V

480
800

Continuous: Phase/N
1 second: Phase/N

V
V

276
460

Continuous
0.5 s
10 ms

A
A
A

76
-2000

6
110
--

Direct

Transformer /5 A

Phase/phase
Phase/N

V
V

400
230

Phase/phase
Phase/N

V
V

87 ... 480
50 ... 276

A
A

63
0.3 ... 63

5
0.012 ... 5

A
A

---

5 ... 5000
5

Hz
Hz

50
45 ... 65

Overload capability
Voltage

Current

Measuring inputs
Connection type
Voltage Ue
- Operating range voltage
Current Ie
- Operating range current
Transformer current
Frequency
- Operating frequency range

Primary current of the transformer


Smallest input step

Siemens LV 10.1 2011

11/17

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multicounters
PAC3000 multicounters without communication interface

7KT1 310

7KT1 311

PAC3000 multicounters with RS 485 interface (Modbus RTU, for LAN couplers)

7KT1 340

7KT1 341

Standards

EN 61010-1, EN 62053-21, -23, -31

Display

11

Connection errors

Inverted phases

Voltage: 3 displays, 3-digit

Delta L1 L2, L2 L3, L3 L1


Star L1/N L2/N L3/N
Voltage > 480/276 V
Voltage < 87/50 V

Err

Current:

L1 L2 L3 neutral conductor

0.3 ... 76 A

For current > 76 A or


6 A x transformer conversion ratio
For current < 0.3 A or
0.012 A x transformer conversion ratio

HHH

V AC
V AC

87 ... 480
50 ... 276
HHH
LLL
0.1 A ... 1.2 kA or
0.1 ... 6 A
transformer conversion ratio

OOO

Frequency: 1 display, 3-digit

Hz

45.0 ... 65.0

Active power: 3 displays, 3-digit

L1 L2 L3,
display with floating decimal point

W, kW
or MW

0 ... 999

Active power: 3 displays, 3-digit,


3 of 7 digits +
display import or export

L,
display with floating decimal point

W, kW
or MW

0 ... 999

Reactive power: 1 display,


3 of 7 digits + capacitive
or inductive load

L,
display with floating decimal point

var, kvar or 0 ... 999


Mvar

Apparent power: 3 displays, 3-digit

L1 L2 L3, L
display with floating decimal point

VA, kVA or
MV

0 ... 999

Apparent power: 5 displays, 3-digit,


adjustable

L,
display with floating decimal point

VA, kVA or
MV

0 ... 999

Active energy: 1 display, 7-digit


display import or export,
+ display rate 1 or 2

L,
display with floating decimal point

Wh, kWh or 0 ... 9999999


MW
or 0 ... 999

Reactive energy: 1 display, 7-digit


+ capacitive or inductive load

L,
display with floating decimal point

varh, kvarh 0 ... 9999999


or Mvarh
or 0 ... 999

Apparent energy: 5 displays, 3-digit,


adjustable rate

L,
display with floating decimal point

VAh, kVAh
or MVh

p.f.: 3 displays, 3-digit

L1 L2 L3,
display with floating decimal point

0.01 ... 1.00

p.f.: 4 displays, 3-digit,


adjustable

0.01 ... 1.00

Transformer primary current

Only if set

--

5 ... 5000

Transformer secondary current

Only if set

--

Temperatures

0 ... +99

Display period

/s

0 ... 9999999
or 0 ... 999

EEPROM

Storage of setting and energy values


S0 interface

Acc. to IEC 62053-31

Terminal output

for direct connection 63 A, adjustable

Imp/kWh

Class A
10 1 0.1 0.01 0.001

--

Depending on the transformer factor,


adjustable

Imp/kWh

--

10 1 0.1 0.01 0.001

Pulse duration

ms

125 ... 300

Minimum interval between 2 pulses

ms

300

Required voltage

V DC

5 ... 30

Current ON/OFF

mA

10 ... 27/0 ... 2

Voltage

Current

Power outputs

Measuring accuracy

Active energy

Acc. to IEC 62053-21

Reactive energy

Acc. to IEC 62053-23

Class 2
Class 2

P.f.

Frequency

Safety according to EN 61010-1


Pollution degree

2
II

Overvoltage category
Operating voltage category

600

Clearances

mm

 3.0

In device
On printed boards (not installed)

mm
mm

 4.3
 3.0

Test pulse voltage

1.2/50 s

kV

Test voltage

50 Hz, 1 min

kV

2.2

Creepage distances

11/18

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multicounters

PAC3000 multicounters without communication interface

7KT1 310

7KT1 311

PAC3000 multicounters with RS 485 interface (Modbus RTU, for LAN couplers)

7KT1 340

7KT1 341

Standards

EN 61010-1, EN 62053-21, -23, -31

Terminals
Main current paths

screw (Pozidriv)

Supply and control terminals

Blade for slotted screw

mm mm

2
0.4 2.5

Conductor cross-sections, main current paths

Rigid, maximum

mm2

1 25 or
2 16

Rigid, minimum

mm2

1 1.5

Conductor cross-sections
Supply and control terminals

Rigid, maximum

mm2

1 6 or
24

Flexible, with end sleeve, minimum

mm2

1 0.75

Temperatures

0 ... +55

Relative humidity

 80

mm

0.25

1
1 6 or
24

Ambient conditions

Vibrations

Sinus amplitude at 50 Hz

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Safety class

Acc. to EN 61010-1

II

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

PAC3000 multicounters
For the display of 35 electrical values, of which
5 or 6 values can be continuously displayed.
For 3-phase, 3/4-wire connection,
with S0 interface

11

Without communication interface


Standard rail mounting
For direct connection
3 230/400

63

230

7KT1 310

1 unit

027

0.478

7KT1 311

1 unit

027

0.421

7KT1 340

1 unit

027

0.484

7KT1 341

1 unit

027

0.430

For transformer connection 5 ... 5000 A,


adjustable in 5 A steps, secondary current 5 A
3 230/400

transformer /5

230

7KT1 310

With RS 485 interface and RTU Modbus


protocol or for connection to LAN networks over 7KT1 390 or 7KT1 391
LAN coupler
Standard rail mounting
For direct connection
3 230/400

63

230

For transformer connection 5 ... 5000 A,


adjustable in 5 A steps, secondary current 5 A
3 230/400

transformer /5

230

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/19

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3000 multicounters

More information
Readout data
You can continuously display 6 measured quantities from the following 35 options.

11

No.

Measured value

Display

Unit

Assignment

Active power

D1

L1

Voltage

D1

L1

Current

D1

L1

Apparent power

D1

VA

L1

P.f.

D1

P.f.

L1

Voltage

D1

L1 L2

Active power

D2

L2

Voltage

D2

L2

Current

D2

L2

10

Apparent power

D2

VA

L2

11

P.f.

D2

P.f.

L2

12

Voltage

D2

L2 L3

13

Active power

D3

L3

14

Voltage

D3

L3

15

Current

D3

L3

16

Apparent power

D3

VA

L3

17

P.f.

D3

P.f.

L3

18

Voltage

D3

L3 L1

19

Temperatures

D6

20

Current, N conductor

D6

21

Active power

D4

22

Reactive power

D5

var

23

Apparent power

D5

var

24

Frequency

D6

Hz

25

P.f.

D1, D2, D3, D6

P.f.

26

Active energy rate 1

D4

Wh

27

Active energy rate 2

D4

Wh

28

Active energy rate 1

D4

Wh

L 

29

Active energy rate 2

D4

Wh

L 

30

Reactive energy rate 1

D5

varh

L, ind.

31

Reactive energy rate 2

D5

varh

L, ind.

32

Reactive energy rate 1

D5

varh

L, chap.

33

Reactive energy rate 2

D5

varh

L, chap.

34

Apparent energy rate 1 D5

VAh

35

Apparent energy rate 2 D5

VAh

2 set values are also indicated:


36

Transformer setting

D4

CT/A

/5

37

Transformer setting

D5

CT/A

5 ... 5000

All the measured values are transmitted via LAN.

11/20

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
7KT1 391 LAN couplers

Overview

Application
Usable E-counters and multicounters
Following E-counters and multicounters can be connected
to the LAN coupler:
Order No.
Energy counters
Digital 3-phase counters

7KT 391 LAN couplers

PAC1500, for direct connection 80 A, double rate

7KT1 543

PAC1500, for direct connection 80 A, double rate,


calibrated version

7KT1 545

PAC1500, for transformer connection .../5 A, double


rate

7KT1 540

For transformer connection .../5 A, double rate,


calibrated version

7KT1 542

For direct connection 125 A, double rate

7KT1 546

For direct connection 125 A, double rate,


calibrated version

7KT1 548

For direct connection 63 A, double rate

7KT1 520

For transformer connection .../5 A, double rate

7KT1 521

A LAN coupler supports worldwide data recall from multicounters and E-counters over a LAN link to the Internet.

Digital 1-phase counters


PAC1500, for direct connection 80 A, double rate

7KT1 531

Up to 30 devices can be linked with a LAN coupler. In turn, the


LAN coupler is connected to a LAN.

PAC1500, for direct connection 80 A, double rate,


calibrated version

7KT1 533

Data communication between the LAN coupler and the PC takes


place using the TCP/IP protocol.

Multicounters

Benefits

PAC3000, for direct connection

7KT1 340

PAC3000, for transformer connection .../5 A

7KT1 341

For transformer connection .../5 A

7KT1 342

Integration of measuring devices in industrial or office communication


Use of existing local networks (LAN) for transmitting the measured data
The internal storage possibility (2 GByte internal memory)
makes a permanent connection unnecessary
TCP/IP data protocol enables a wide range of application
Data output in csv files enables the implementation of customized solutions for measured data indication and analysis
One LAN coupler for up to 30 devices

11

Siemens LV 10.1 2011

11/21

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
7KT1 391 LAN couplers

Technical specifications
7KT1 391
IEEE 802.3 AS, IEC 60950, EN 61000-6-2, EN 61000-6-3

Standards
General data
Enclosures
Mounting
Mounting height

Acc. to DIN 43880


Acc. to EN 60715

Supply
Rated power dissipation Pv
Rated control supply voltage Uc
Primary operating range
Rated frequency
Frequency ranges
Function
System start
LAN server identification
Transmission rate
Operating system
Browser

Limitation by LAN

mm

4 modules
Mounting onto standard mounting rail (35 mm)
70

VA
V AC
Uc
Hz
Hz

 10
230
0.9 ... 1.10
50
45 ... 65

Mbit/s

Automatic upon switching on


Over the IP address of the PC
100
Windows XP/Vista/7
IE 7, 8; Mozilla Firefox 3.09 / 3.5.3 / 3.6; Opera 9.64 / 10 / 10.5;
Safari 3.2.2 /4.0.5; Google Chrome 3.0.195.27.

LAN interface
HW interface

Connection RJ 45

SW interface

TCP/IP

Interface to the measuring instruments


HW interface

RS 485 terminals

Number 3 (+/-/shielded twisted pair)

Line

Version
Minimum cross-section
Maximum line capacity
Impedance
Maximum overall cable length
Type of installation

mm2
pF/m
W
m

Measuring instruments can be connected


directly

11

Safety according to IEC 60950


Pollution degree
Overvoltage category
Operational voltage
Enclosure material group
Clearances
Creepage distances
Test pulse voltage
Flame resistance

STP (shielded twisted pair)


2 0.2 or 2 x AWG 24
< 50
100
 1200
Serial

Number 30

kV
kV
Class

2
III
300
II
 4.0
 4.5
4
4
V0

kJ

2977.8

V
mm
1.2/50 s
50 Hz, 1 min
Acc. to UL 94

Fire load
Terminals
Lift terminals

screw (Pozidriv)

PZ1

Conductor cross-sections of main current Rigid


paths
Flexible with sleeve
Environmental conditions
Temperatures

Relative humidity
Vibrations
Safety class
Degree of protection

mm2

0.75 ... 6

0.75 ... 6

mm

In operation
Storage and transport
In operation
Sinus amplitude at 50 Hz
acc. to IEC 60950
Installed device front side (terminals)

C
C
%
mm

-10 ... +55


-25 ... +70
 80
0.25
III
IP20

Selection and ordering data


Uc

Mount- DT
ing
width

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

LAN couplers
For connection of up to 30 devices over RS 485
230

7KT1 391

1 unit

027

0.205

* You can order this quantity or a multiple thereof.

11/22

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3100, PAC3200 and PAC4200
power monitoring devices

Overview
Measuring precisely with SENTRON PAC3100/3200/4200

Benefits
SENTRON PAC General
The common features of all power monitoring devices in the
SENTRON PAC series:
Simple mounting and commissioning
High IP65 degree of protection (front side, when installed) permits usage in extremely dusty and wet environments
Intuitive operation using 4 function buttons and multilingual
plain text displays
Easy adaptation to different systems using integrated and optional
- Digital inputs and outputs
- Communication interfaces
Worldwide use
- Min. 8 languages
- International approvals
- Developed and tested to European and international standards
Low mounting depth

The SENTRON PAC power monitoring devices:


PAC3200 (left), PAC3100 (center) and PAC4200 (right)

The power monitoring devices of the SENTRON PAC series are


used to measure and indicate all relevant network parameters in
low-voltage power distribution. They can be used for singlephase measurements as well as for multiphase measurements in
3 and 4-conductor networks (TN, TT, IT).
Power values for main distribution boards, electrical feeders or
individual loads are recorded precisely and reliably, and important measured values are supplied in addition for assessing the
state of the plant and the quality of the network.

More information
More information is available on the Internet at
www.siemens.com/powermanagementsystem

SENTRON PAC3200 and SENTRON PAC4200


Additional performance characteristics of the SENTRON
PAC3200 and SENTRON PAC4200:
Precise energy recording
Versatile system integration
- Integrated Ethernet interface
- Optional communication modules available
- Multifunctional digital inputs and outputs
- Limit value monitoring
Can be connected directly to power supply networks up to
690 V AC (UL-L) , CATIII without voltage transformers.
Easy-to-use configuration software included as standard
SENTRON PAC4200
Additional performance characteristics of the SENTRON
PAC4200:
Monitoring the plant status and the system quality
- Basic information for evaluating network quality
- Logging of plant history in the form of operation, control and
system-related events
Recording of the power range through power averaging (load
profile)
Daily energy meters for apparent, active and reactive energy
across 365 days for cut-off date assessment
Detection of gas, water, compressed air or other energy
sources via pulse counter to the digital inputs
Can be expanded using modules to up to 10 digital inputs and
6 digital outputs
Meters for apparent, active and reactive energy for the precise
detection of the power consumption of a partial process or
manufacturing process
10/100 Mbit/s Ethernet interface with gateway function for the
easy connection of devices with serial RS485 interface via expansion module PAC RS485 to an Ethernet network
Comprehensive convenience indicators, such as user-defined
displays, bar and status indicators, phase diagram and list
and histogram graphics
Satisfies the accuracy requirements of class 0.2S high-precision meters used by power supply companies according to
IEC 62053-22, which are normally reserved for exacting industrial applications

Siemens LV 10.1 2011

11/23

11

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3100, PAC3200 and PAC4200
power monitoring devices
System integration of RS485 field bus devices through Ethernet

Application
Three-phase power monitoring devices are used to measure
and indicate all relevant network parameters of an electrical installation and they monitor these parameters permanently.
Applications
Wherever power has to be distributed, be it in industrial or infrastructural buildings, the SENTRON PAC supplies important information to the building services system or the power controlling
system.
The many different communication options offered by the
SENTRON PAC make it an indispensable supplier of data for
energy management systems and for plant and building automation.

A special feature is the integrated gateway function of the


SENTRON PAC4200. It enables a cost-effective and simple
connection of devices with an RS485 interface to an Ethernet
network.
Everything required is provided by the SENTRON PAC RS485
expansion module, to which a maximum of 31 lower-level devices can be connected without a repeater and as many as 247
with a repeater.
The gateway function of the SENTRON PAC4200 supports the
Modbus protocol and can be parameterized using SENTRON
powerconfig.
SQL
database

Server

Client

Client

Industries
Power distribution systems for the power supply are needed in
all sectors of industry. SENTRON PAC is used accordingly in all
sectors where power consumption and electrical parameters are
to be measured.

Ethernet

Integration of PAC3200 and PAC4200


When the SENTRON PAC3200 and PAC4200 are fully integrated
in a energy management system, they monitor the power consumption and help to monitor the operating state of the plant.
Measured values, limit value violations, operating hours of a connected load or power flows are supplied by the instruments
quickly and reliably.

SENTRON PAC4200
with serial gateway

NSG0_00238a

Using the optionally available interface modules, it is possible to


integrate both instruments in every I&C system or every
SIMATIC S7 environment.
System integration using block libraries

11

Optionally available block libraries make it easy to integrate the


power monitoring devices in the SIMATIC PCS 7 process control
system and the SCADA-System SIMATIC WinCC. Together with
the faceplates as user interface for SENTRON PAC3200, the
driver blocks and diagnostics blocks in the control system enable the operating and monitoring of technologically important
values and functions of the measuring devices in the respective
target system.

Faceplates

Industrial Ethernet

PROFIBUS
PROFIBUS

Libraries for PCS7


and WinCC

16(BF

Integration of the SENTRON PAC3200 in SIMATIC PCS 7/WinCC

11/24

Siemens LV 10.1 2011

SENTRON
PAC3200

Modbus RTU

SENTRON VL

Power monitoring devices


SENTRON WL

Connecting Modbus-RTU devices to a power management system


through PAC4200

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3100, PAC3200 and PAC4200
power monitoring devices

Technical specifications

Instrument variants

SENTRON PAC3100

PAC3200

PAC4200

Basic measurement variables


Voltage, current

Neutral conductor current

--

Apparent power, active power, reactive power, power factor

Power factor of the fundamental


wave

--

--

Frequency

Of the reference phase

Min/max values

Slave pointer function | with date & time

| --

| --

Power measurement
--

Active energy, reactive energy

Input | Output | Balance

||

| | --

| | --

Number of tariffs

Apparent, active and reactive energy

Daily energy values for 365 days

Apparent, active and reactive energy

--

--

Consumption recording of a subprocess or manufacturing process

Apparent, active and reactive energy

--

--

Power averages of the last measure- Active and reactive power average with
ment period
min / max value

Load profile record

--

--

max. 3840 entries1)

Apparent energy

E-counter for S0 signal at a digital


input

Electrical energy | any energy

-- | --

| --

Accuracy class for active energy

Acc. to IEC 62053-21 / 62053-22

Class 1

Class 0.5S

Class 0.2S

Accuracy class for reactive energy

Acc. to IEC 62053-23

Class 3

Class 2

Class 2

Monitoring of state of the plant and quality of the network


Configurable displays

For presenting up to 4 measured quantities

--

--

Operating hours counter

Operating hours of loads

--

Sliding mean values

U, I, S, P, Q, LF

--

--

THD voltage, current

--

THD-R

THD

Distortion current strength

--

--

Phase angle, phase displacement angle

--

--

Unbalance

--

Unba | Inba2)

Unb | Inb3)

Voltage | current

Harmonics in voltage, current

11

--

--

3. to 31st

Limit value monitoring

Max. number of limit values

--

12

Boolean logic

For limit values | inputs

--| --

| --

Event memory for operation, control Including time stamp


and system-related events

--

--

(> 4000 events)

Battery backup for min / max values

--

--

System integration and communication


Ethernet (integrated)
Protocol

Modbus TCP

---

10 Mbit/s

10/100 Mbit/s

Gateway

Ethernet <--> RS485 (Modbus)

--

--

4)

PROFIBUS DP-V1

--

Expansion module optional

RS 485
Protocol

Modbus RTU

Integrated

Expansion module optional

4DI/2DO expansion module

Expansion to max. 10 DI / 6 DO

--

--

Number of expansion modules

Max.

--

Integrated digital inputs (DI)


Integrated digital outputs (DO)

Number | multifunctional
Number | multifunctional

2 | -2|

1|
1|

2|
2|

Dimensions (L x W x D)

In mm

96 x 96 x 56

96 x 96 x 56

96 x 96 x 82

Mounting depth

PAC | PAC with expansion module (in mm)

51 | --

51 | 73

77 | 99

Panel cutout (L x W)

In mm

92 x 92

92 x 92

92 x 92

CE / cULus / C-Tick / GOST

IEC 61557-12

--

(max. 2 modules)

Installation plan

Standards and approvals

1)
2)

This corresponds for example to a duration of 40 days with a measurement


period length of 15 minutes.
Unba, Inba - Unbalance with regard to amplitude

3)

Unba, Inba - Unbalance with regard to amplitude and phase

4)

In conjunction with SENTRON PAC RS485 expansion module

= Available, -- = Not available

Siemens LV 10.1 2011

11/25

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3100 power monitoring devices

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

SENTRON PAC3100

Screw terminals

A
Control panel flush-mounting instrument
96 mm x 96 mm
Screw terminals for connecting current and
voltage

7KM3 133-0BA00-3AA0

1 unit

133

0.325

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.

AC/DC universal power supply unit


UAUX:
100 240 V AC 10 %, 50/60 Hz
110 250 V DC 10 %

7KM3 133-0BA00-3AA0

Measuring inputs
Ue: max. 3 AC 480/277 V, 50/60 Hz
Ie: /5 A

Accessories
Version

DT

Order No.

Price
per PU

kg
SENTRON PAC TMP
Adapter for mounting on standard
mounting rail

11

7KM9 900-0YA00-0AA0

1 unit

133

0.105

7KM9 900-0YA00-0AA0

More information
Current transformers

Software components

Suitable current transformers can be found


in chapter 2 "Molded Case Circuit Breakers"
in the Industry Mall, section "Industry Automation and Drive
Technologies" --> "Low-Voltage Power Distribution and
Electrical Installation Technology" --> "Protection Devices"
--> "Molded Case Circuit Breakers"
--> "3VL Molded Case Circuit Breakers"
--> "3VL Molded Case Circuit Breakers up to 1600 A"
--> "Accessories and Spare Parts"

For more information about the software components


see chapter 13 and on the Internet at
www.siemens.com/powermanagementsystem

* You can order this quantity or a multiple thereof.

11/26

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC3200 power monitoring devices

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

SENTRON PAC3200

Screw terminals

A
Control panel flush-mounting instrument
96 mm x 96 mm
Screw terminals for connecting current and
voltage

7KM2 112-0BA00-3AA0

1 unit

133

0.325

1 unit

133

0.325

1 unit

133

0.325

AC/DC universal power supply unit


UAUX:
95 240 V AC 10 %, 50/60 Hz
110 340 V DC 10 %

7KM2 112-0BA00-3AA0

Measuring inputs
Ue: max. 3 AC 690/400 V, 50/60 Hz
Ie: /1 A or /5 A
SENTRON PAC3200

Screw terminals

A
Control panel flush-mounting instrument
96 mm x 96 mm
Screw terminals for connecting current and
voltage

7KM2 111-1BA00-3AA0

DC power supply unit with extra-low voltage


UAUX: 2265 V DC 10 %
Measuring inputs
Ue: max. 3 AC 500/289 V, 50/60 Hz
Ie: /1 A or /5 A
7KM2 111-1BA00-3AA0
SENTRON PAC3200
Control panel flush-mounting instrument
96 mm x 96 mm
Cable lug terminals for connecting current
and voltage

Ring terminal lug


connection
A

7KM2 112-0BA00-2AA0

11

AC/DC universal power supply unit:


UAUX:
95240 V AC 10 %, 50/60 Hz
110340 V DC 10 %

7KM2 112-0BA00-2AA0

Measuring inputs
Ue: max. 3 AC 690/400 V, 50/60 Hz
Ie: /1 A or /5 A

Accessories
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

SENTRON PAC TMP


Adapter for mounting on standard
mounting rail

7KM9 900-0YA00-0AA0

1 unit

133

0.105

7KM9 900-0YA00-0AA0

More information
Current transformers

Software components

Suitable current transformers can be found


in chapter 2 "Molded Case Circuit Breakers"
in the Industry Mall, section "Industry Automation and Drive
Technologies" --> "Low-Voltage Power Distribution and
Electrical Installation Technology" --> "Protection Devices"
--> "Molded Case Circuit Breakers"
--> "3VL Molded Case Circuit Breakers"
--> "3VL Molded Case Circuit Breakers up to 1600 A"
--> "Accessories and Spare Parts"

Software for PAC3200 see chapter 13, section "Configuring,


visualizing and controlling with SIMATIC"
For more information about the software components
see chapter 13 and on the Internet at
www.siemens.com/powermanagementsystem

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/27

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC4200 power monitoring devices

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

SENTRON PAC4200

Screw terminals

A
Control panel flush-mounting instrument
96 mm x 96 mm
Screw terminals for connecting current and
voltage

7KM4 212-0BA00-3AA0

1 unit

133

0.450

1 unit

133

0.450

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.

NSG0_00230

AC/DC universal power supply unit


UAUX:
95 240 V AC 10 %, 50/60 Hz
110 340 V DC 10 %

7KM4 112-0BA00-3AA0

Measuring inputs
Ue: max. 3 AC 690/400 V, 50/60 Hz
Ie: /1 A or /5 A
SENTRON PAC4200
Control panel flush-mounting instrument
96 mm x 96 mm
Cable lug terminals for connecting current
and voltage

Ring terminal lug


connection
A

7KM4 212-0BA00-2AA0

DT

Order No.

AC/DC universal power supply unit:


UAUX:
95240 V AC 10 %, 50/60 Hz
110340 V DC 10 %

7KM4 112-0BA00-2AA0

Measuring inputs
Ue: max. 3 AC 690/400 V, 50/60 Hz
Ie: /1 A or /5 A

Accessories

11

Version

Price
per PU

kg
SENTRON PAC TMP
Adapter for mounting on standard
mounting rail

7KM9 900-0YA00-0AA0

1 unit

133

0.105

7KM9 900-0YA00-0AA0

More information
Current transformers

Software components

Suitable current transformers can be found


in chapter 2 "Molded case circuit breakers"
in the Industry Mall, section "Industry Automation and Drive
Technologies" --> "Low-Voltage Power Distribution and
Electrical Installation Technology" --> "Protection Devices"
--> "Molded Case Circuit Breakers"
--> "3VL Molded Case Circuit Breakers"
--> "3VL Molded Case Circuit Breakers up to 1600 A"
--> "Accessories and Spare Parts"

For more information about the software components


see chapter 13 and on the Internet at
www.siemens.com/powermanagementsystem

* You can order this quantity or a multiple thereof.

11/28

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC PROFIBUS DP expansion modules

Overview
The PAC PROFIBUS DP expansion module has the following
features:
Pluggable PROFIBUS DP communication modules for
SENTRON PAC3200 and PAC4200 power monitoring devices
Parameterizable from the front of the device or using parameterization software
Using PROFIBUS DPV1, data can be transferred in both cyclic
and acyclic modes
Easy engineering thanks to integration into SIMATIC STEP 7
and/or simple integration via GSD file for other programming
systems
Optimum use of process image of a control for selection of individual measurment values for cyclical transfer
All baudrates from 9.6 kbit/s up to 12 Mbit/s are supported
Connection through 9-pole Sub-D connector according to
IEC 61158
No external auxiliary power necessary
Additional display via the device display and via LEDs on the
module

SENTRON PAC PROFIBUS DP expansion modules

Application
The SENTRON PAC PROFIBUS DP communication module is
plugged onto the rear of the power monitoring device. The device identifies the module automatically and presents the parameters of relevance for this module for selection in the parameterization menu.

All individual measurement variables supplied by the SENTRON


PAC multifunction measuring instruments are selected and cyclically transmitted by means of the GSD file. This permits the optimum use of the PROFIBUS Master process image.

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

PAC PROFIBUS DP
Expansion module for
A
SENTRON PAC3200 and PAC4200
(PROFIBUS DP V1)

7KM9 300-0AB00-0AA0

1 unit

133

0.045

7KM9 300-0AB00-0AA0

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/29

11

Siemens AG 2011

Measuring Devices and E-Counters


Power Monitoring Devices
PAC RS485 expansion modules

Overview
The SENTRON PAC RS485 expansion module has the following
features:
PAC RS485 plug-in communication module for SENTRON
PAC3200 and PAC4200 power monitoring devices
Parameterizable from the front of the device or using parameterization software
Support for the Modbus RTU protocol
Plug and play
Baud rates 4.8 / 9.6 / 19.2 and 38.4 kBd are supported
Connection by means of 6-pole screw terminals
No external auxiliary power necessary
Status indication by LED on the module

SENTRON PAC RS485 expansion module

Application
The SENTRON PAC RS485 communication module is plugged
into the back of the PAC power monitoring device.
The device identifies the module automatically and presents the
parameters of relevance for this module for selection in the parameterization menu. The state of the module is indicated by the
integrated LED.

11

In connection with the SENTRON PAC3200 and 4200 multifunction measuring instruments, the Modbus RTU protocols are supported with baud rates of 4.8/9.6/19.2 and 38.4 kBd.
The SENTRON PAC RS485 expansion module is required for the
gateway function of the PAC4200 to achieve simple devices with
RS485 interface, such as the PAC3100, via Ethernet
(Modbus TCP).

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

PAC RS485
Expansion module for
A
SENTRON PAC3200 and PAC4200
(Modbus RTU)

7KM9 300-0AM00-0AA0

1 unit

133

0.041

7KM9 300-0AM00-0AA0

* You can order this quantity or a multiple thereof.

11/30

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters

Power Monitoring Devices


PAC 4DI/2DO expansion modules for PAC4200

Overview
The SENTRON PAC 4DI/2DO expansion module is used to expand the SENTRON PAC4200 power monitoring device to up to
10 digital inputs and 6 digital outputs.
It offers the following features:
Up to two 4DI/2DO modules can be plugged onto a PAC4200.
The 4DI/2DO modules mean that the internal digital inputs and
outputs can be expanded by up to 8 inputs and 4 outputs.
The 4DI/2DO expansion modules can be parameterized via
the front of the device or via the SENTRON powerconfig configuration software.
The digital inputs can be used without external voltage
sources. They are self-powered.
All functions of the integrated multifunctional inputs/outputs on
the PAC4200 are also available in the 4DI/2DO expansion
module.
Inputs and outputs can be used as an S0 interface conforming
to IEC 62053-31.
The connection is made via a 9-pole screw terminal.
No external auxiliary power supply is required.

SENTRON PAC 4DI/2DO expansion modules

Application
There are many possible uses for the SENTRON PAC 4DI/2DO
expansion module. Some of these include:
Connection of up to 10 energy counters with pulsed output
(S0) for detecting the consumption of other energy-carriers
e.g. gas, water or compressed-air consumption
Integration of other media into energy management system

Monitoring of multiple, single switches with auxiliary contacts


via PAC4200
Use of the digital outputs as pulse output for active and reactive energy
Use of the digital outputs as outputs for switching operations
and/or for time synchronization.

Benefits
Digital inputs

Digital outputs

Consumption recording and evaluation


Cost-effective energy counters can be used as media counters.
It is not necessary to replace meters as the basic power meters with pulse output already installed can be used.
Other media can be easily integrated into a power management system.
Increase the transparency of the power flows, because the
power consumption of a sub-process or the product-related
power consumption can be detected and evaluated, for example.
Pulse counters can be easily assigned using user-definable
displays.

The digital outputs offer a high degree of flexibility as they can


be used as follows:
For status display
- for a limit value violation
- for a direction of rotation
- for an operating state on the PAC4200
As remote-controlled switching outputs
For synchronization of the periods load profile detection in
other devices
For signaling power measurement
- related active energy
- supplied active energy
- related reactive energy
- supplied reactive energy

Status monitoring
The digital inputs reduce the wiring outlay thanks to the effective
integration of basic protection equipment and switchgear.

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*

PG

Weight
per PU
approx.
kg

PAC 4DI/2DO
Expansion module for
SENTRON PAC4200

7KM9 200-0AB00-0AA0

1 unit

133

0.041

7KM9 200-0AB00-0AA0

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/31

11

Siemens AG 2011

Measuring Devices and E-Counters


Analog Volt- and Ammeters
7KT1 0 measuring devices

Overview

Benefits
The 7KT1 020 ammeters can be equipped with changeable
scales for primary currents of 60, 150 or 400 A AC, depending
on the transformer ratio of the installed current transformer.
The changeable scales are included in delivery. This ensures
universal application
Permanent overload up to 20 % does not damage the device.
Protection for your plant.

These devices for measuring voltages and currents can be used


for monitoring incoming and outgoing currents or device currents in electric plants. They are suitable for direct connection in
a single-phase system or with selector switches for the measured values in three-phase systems.

Technical specifications
7KT1 000
Measuring ranges
Direct measurement

11

7KT1 01.

7KT1 020

-0 ... 25
0 ... 40
0 ... 60
--

----0 ... 150/5

1.5

EN 60051-2

Standards

Transformer measurement

V AC
A AC
A AC
A AC
A AC

0 ... 500
-----

Max. permissible measuring frequency

Hz

45 ... 65
Pointer

Display
at 23 1 C

Measuring accuracy
Rated operational power Ps
Temperature influence
Overload capability

Continuous
Short-time for 1 s

Test voltage

50 Hz, 1 min

Terminals

screw (Pozidriv)

Conductor cross-sections

Rigid, max.
Flexible, with end sleeve, min.

1.5

VA

<2

< 1.1

%/C

0.03
1.2 Umeas
2 Umeas

kV

Permissible ambient temperature

1.2 Imeas
10 Imeas

>2
1

mm2
mm2

1 6/2 4
0.75

1 25/2 16

1 6/2 4
0.75

-10 ... +55


IP20, with connected conductors

Degree of protection

Selection and ordering data


Umeas

Imeas

Mount- DT
ing
width

V AC

A AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Analog voltmeters
500

7KT1 000

1 unit

027

0.137

B
B
B

7KT1 010
7KT1 011
7KT1 012

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.152
0.160
0.168

7KT1 020

1 unit

027

0.136

Analog ammeters for direct connection


25
40
60
Analog ammeter for transformer connection
with 3 different interchangeable scales
0 ... 60 A,
0 ... 150 A and
0 ... 400 A

0 ... 60/5
0 ... 150/5
0 ... 400/5

* You can order this quantity or a multiple thereof.

11/32

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Digital Volt- and Ammeters
7KT1 11, 7KT1 12 measuring devices

Overview

Benefits
The ammeters have 14 measuring ranges from 0 A to 20 A to
0 A to 999 A, which can be set using a coding switch. This
ensures universal application.

Measuring devices 7KT1: Left voltmeter, right ammeter


These devices for measuring voltages and currents can be used
for monitoring incoming and outgoing currents or device currents in electric plants. They are suitable for direct connection in
a single-phase system or with measuring transducers in threephase systems.
The measuring ranges of the ammeter are set at the device with
a coding switch.

Technical specifications
7KT1 110

7KT1 120

DIN 43751-1, -2

Standards
Rated control supply voltage Uc

V AC

230

Primary operating range

Uc

0.9 ... 1.15

Rated frequency

Hz

45 ... 65

Rated operational power Ps

VA

<2

11

Measuring range
Voltage

Direct measurement

V AC

12 ... 600

--

Current

Direct measurement
Transformer measurement

A AC
A AC

---

0.4 ... 20 direct


0.1 ... 1000/5

3 LEDs red; height 10 mm

Display
Voltage

> 600 V
< 12 V

HHH
-- -- --

---

Current

Direct > 20 A
Transformer > 5 A

---

HHH
HHH

Direct < 0.4 A


Transformer < 0.1 A

---

-- -- --- -- --

Measuring cycle
Measuring accuracy

At 23 C

Temperature influence

/s

4 times

0.5 1 digit

%/C

0.03

Overload capability
Voltage

Continuous
Short-time for 1 s

V
V

720
780

---

Current

Continuous, direct
Continuous, transformer

A
A

---

22
5.5

Short-time for 1 s, direct


Short-time for 1 s, transformer

A
A

---

200
50

Electrical isolation
Clearances
Creepage distances in the device
Creepage distances on the printed board

Printed boards not installed

mm
mm
mm

3
 4.3
 3.0

 1.5
 2.1
 1.5

Test voltage

50 Hz, 1 min

kV

2.2

1.35

Terminals

screw (Pozidriv)

Conductor cross-sections

Rigid, max.
Flexible, with end sleeve, min.

Permissible ambient temperature


Degree of protection

1
mm2
mm2

1 6/2 4
0.75

-10 ... +55


IP20, with connected conductors

Siemens LV 10.1 2011

11/33

Siemens AG 2011

Measuring Devices and E-Counters


Digital Volt- and Ammeters
7KT1 11, 7KT1 12 measuring devices

Selection and ordering data


Ue

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

MW

230

7KT1 110

1 unit

027

0.214

230

7KT1 120

1 unit

027

0.219

kg

Digital voltmeters
Measuring range AC 12 ... 600 V

Digital ammeters for


direct and transformer connection
Measuring range
direct:
0.4 ... 20 A
transformer: 0.1 ... 1000 A/5

More information
Range selector switch for 7KT1 120 digital ammeter

11

0
1 2 3 4 1
I2_00183c

1234
Direct measurement
0000
20 A AC
Transformer measurement
1000
25/5 A AC 0 0 0 1
40/5 A AC 1 0 0 1
0100
50/5 A AC 0 1 0 1
1100
0010
60/5 A AC 1 1 0 1
1010
80/5 A AC 0 0 1 1
0110
100/5 A AC 1 0 1 1
1110
150/5 A AC 0 1 1 1

200/5 A AC
250/5 A AC
400/5 A AC
500/5 A AC
600/5 A AC
800/5 A AC
999/5 A AC

* You can order this quantity or a multiple thereof.

11/34

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Time and Pulse Counters
Time and pulse counters
for mounting onto support rail

Overview
and monitoring of production sequences, maintenance cycles
and warranty times.
As well as the proven electromechanical time and pulse counters for mounting in distribution boards, we also supply digital
time and pulse counters.
The fields of application for both counter types are very diverse,
such as the recording of operating hours of machines, systems
or building management systems, as well as pulse counting for
general volume flow counting, registration of starting frequencies, starting cycles or production quantities in systems and machines.

Benefits
Time and pulse counters help to plan maintenance intervals,
which safeguard and ensure high plant availability
Versions without zero position and with electric or manual zero
position for all applications.
Flexible application of the digital counters for power supplies
of 12 V to 150 V DC and 24 V to 240 V AC in a single device.

Time counters: Left: electromechanical, right: Electronic

Time and pulse counters are used for the reliable monitoring of
production and service times, which enables the exact planning

Technical specifications
7KT5 801

Rated control supply voltage Uc


At 50/60 Hz

V AC
V DC

-12 ... 24

Uc

0.9 ... 1.1

Rated frequency

Hz

--

Rated power dissipation Pv

VA

<1

Primary operating range

7KT5 802

7KT5 803

7KT5 804

7KT5 806

7KT5 807

EN 60255-6; UL 863
UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55

Standards
Approvals

Method of operation

Counting of

Display

Drum-type register

Terminals

screw (Phillips)

Conductor cross-sections

Rigid
Flexible, with end sleeve, min.

Permissible ambient temperature


Degree of protection

Acc. to EN 60529

Safety class

Acc. to EN 61140

115

230

115

50

230

60

11

<2

Hours
h

00000.00
1

mm2
mm2

1.5
0.75

-10 ... +70


IP20, with connected conductors
II

Permissible humidity

24
--

< 80

7KT5 811 7KT5 812 7KT5 814 7KT5 821 7KT5 822 7KT5 823 7KT5 833
EN 60255-6; UL 863
UL 863, UL File No. E300537, CSA C22.2 No. 6 and 55

Standards
Approvals
Rated control supply voltage Uc

-12 ... 24

Uc

0.9 ... 1.1

Rated frequency

Hz

--

Rated power dissipation Pv

VA

<1

Primary operating range

At 50/60 Hz

V AC
V DC

24
--

230
--

24 ... 240
12 ... 150

<2

<1

50/60

Method of operation

Counting of

Pulses

Hours

Pulses

Display

Drum-type register
LCD

0000000
---

-000000.0
--

--0000000

Counting frequency

Hz

10

--

10

Pulse duration

ms

50

--

Resetting

Electrical
Mechanical

---

Terminals

screw (Phillips)

Conductor cross-sections

Rigid
Flexible, with end sleeve, min.

Permissible ambient temperature


Degree of protection

Acc. to EN 60529

Safety class

Acc. to EN 61140

Permissible humidity

mm2
mm2

1.5
0.75

-10 ... +70

50
Yes
Yes

IP20, with connected conductors


II
%

< 80

Siemens LV 10.1 2011

11/35

Siemens AG 2011

Measuring Devices and E-Counters


Time and Pulse Counters
Time and pulse counters
for mounting onto support rail

Selection and ordering data


Uc

Frequency Mount- DT
ing
width

Hz

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Time counters
Mechanical counting mechanism,
display 00000.00 h without resetting
12 ... 24 DC

--

7KT5 801

1 unit

027

0.098

24 AC
115 AC
230 AC

50

A
B
A

7KT5 802
7KT5 803
7KT5 804

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.093
0.093
0.093

115 AC
230 AC

60

B
B

7KT5 806
7KT5 807

1
1

1 unit
1 unit

027
027

0.094
0.095

7KT5 811

1 unit

027

0.095

B
B

7KT5 812
7KT5 814

1
1

1 unit
1 unit

027
027

0.089
0.096

7KT5 821

1 unit

027

0.089

7KT5 822

1 unit

027

0.085

7KT5 823

1 unit

027

0.089

7KT5 833

1 unit

027

0.089

Pulse counters
Mechanical counting mechanism,
display 0000000
without resetting
12 ... 24 DC

--

24 AC
230 AC

50/60

Electronic time counters


LCD 000000.0 h without resetting
DC 12 ... 150,
AC 24 ... 240

-50/60

With electrical resetting


DC 12 ... 150,
AC 24 ... 240

-50/60

With electrical and mechanical resetting


DC 12 ... 150,
AC 24 ... 240

-50/60

Electronic pulse counters


LCD 0000000

11

With electrical and mechanical resetting


DC 12 ... 150,
AC 24 ... 240

-50/60

More information
Time counters count the time in hours with an accuracy of two
decimal places (hundredths of hours). The pulse counter adds
the number of pulses, e.g. the making operations of devices.
A power supply is required at terminals 1 and 3 of the electronic
counters so that the device can constantly display the measured
values. Once terminal 3 is supplied with voltage (for DC "+"), the
counting procedure starts. If terminal 4 is supplied short-time
with voltage (for DC "+"), the counter is reset.
In the case of electronic counters, the counting result is saved
indefinitely in the event of a power failure (EEPROM). On recovery of the power, the counting is continued from the saved value.
As well as a modern design, the electronic counter has a 7-digit
LCD, which can be reset electrically or manually.

* You can order this quantity or a multiple thereof.

11/36

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Time and Pulse Counters
Time counters for front-panel mounting

Overview
Time and pulse counters for control cabinets, control and mechanical engineering are used, e.g. in boilers, machine tools or
compressors. The pulse counters count the starting frequencies.
This supports planning for preventative maintenance.
In-time and regular maintenance is the best protection against
unexpected shutdowns.

Benefits
Time and pulse counters help to plan maintenance intervals,
which safeguard and ensure high plant availability.

Time counters: Left: Counting mechanism, right: Counting mechanism


with front frame

Technical specifications
7KT5 500

7KT5 501

7KT5 502

7KT5 503

7KT5 504

7KT5 505

115
--

230

115

230

24

EN 60255-6

Standards
Rated control supply voltage Uc

V AC
V DC

-10 ... 80

Primary operating range

Uc

0.9 ... 1.1

Rated frequency

Hz

--

50

Rated power dissipation Pv

VA

<1

0.2

Method of operation

Counting of

Display

Drum-type register

00000.00

Pulse duration

Pulse length, pulse interval

ms

50

Front-panel mounting
Without masking frame
55 mm 55 mm
With masking frame
55 mm 55 mm

Switchboard cutout

Terminals

screw (Phillips)

Conductor cross-sections

Rigid
Flexible, with end sleeve, min.

Degree of protection
Front panel
Installation with seal
Terminals

Acc. to EN 60529

Safety class

Acc. to EN 61140

1.8

0.2

11

mm mm 45.2 45.2+0.3
50.2+0.3
1
mm2
mm2

1.5
0.75

-10 ... +70


IP65
IP43
IP20, with connected conductors
II

Permissible humidity

< 93

7KT5 600

7KT5 601

7KT5 602

7KT5 603

7KT5 604

115
--

230

115

230

EN 60255-6

Standards
Rated control supply voltage Uc

V AC
V DC

-10 ... 50

Primary operating range

Uc

0.9 ... 1.1

Rated frequency

Hz

--

Rated power dissipation Pv

VA

<1

Method of operation

Counting of

Display

Drum-type register

00000.00

Pulse duration

Pulse length, pulse interval

ms

50

Front-panel mounting

Switchboard cutout

mm mm

68+0.5 68+0.5

Terminals

screw (Phillips)

Conductor cross-sections

Rigid
Flexible, with end sleeve, min.

Permissible ambient temperature


Degree of protection
Front panel
Terminals

Acc. to EN 60529

Safety class

Acc. to EN 61140

Permissible humidity

50

0.9

Hours

mm

Permissible ambient temperature

60
1.8

50

60

Hours

1
mm2
mm2

1.5
0.75

-10 ... +70


IP52
IP00
II

< 93

Siemens LV 10.1 2011

11/37

Siemens AG 2011

Measuring Devices and E-Counters


Time and Pulse Counters
Time counters for front-panel mounting

Selection and ordering data


Uc

Frequen- Mount- DT
cy
ing
width

Hz

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

MW

Time counters
Mechanical counting mechanism, display
00000.00 h,
For front-panel mounting, front frame 48 mm x 48 mm
10 ... 80 DC

7KT5 500

1 unit

027

0.059

24 AC
115 AC
230 AC

50

A
A
A

7KT5 505
7KT5 501
7KT5 502

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.056
0.058
0.057

115 AC
230 AC

60

A
A

7KT5 503
7KT5 504

1
1

1 unit
1 unit

027
027

0.058
0.058

For front-panel mounting, front frame 72 mm x 72 mm


with narrow frame acc. to DIN 43700
10 ... 50 DC

7KT5 600

1 unit

027

0.131

115 AC
230 AC

50

B
A

7KT5 601
7KT5 602

1
1

1 unit
1 unit

027
027

0.128
0.129

115 AC
230 AC

60

B
B

7KT5 603
7KT5 604

1
1

1 unit
1 unit

027
027

0.128
0.129

7KT9 020

1 unit

027

0.005

7KT9 000

1 set

027

0.011

7KT9 021

1 unit

027

0.003

Covers for 7KT5 5 time counters


55 mm 55 mm
Sealing rings for 7KT9 020 covers
IP43 installation in switchboards with smooth surfaces
(1 set = 5 units)
Terminal covers for 7KT5 6 time counters
Degree of protection, IP20, with connected conductors

11

* You can order this quantity or a multiple thereof.

11/38

Siemens LV 10.1 2011

Siemens AG 2011

Measuring Devices and E-Counters


Accessories
7KT1 2 current transformers

Overview

Benefits
The current transformer has accuracy class 1 in accordance
with EN 60044-1. This value is better than most measuring devices in this area of application.
The versions designed for a transformer ratio of 60/5 A,
100/5 A and 150/5 A enable an even broader range of applications.

This 3-phase current transformer can be used in distribution


boards according to DIN 43880. The measuring leads are routed
vertically through the standard mounting rail.
This type of current transformer is suitable for supply systems or
outgoing conductors in connection with the installation of a 5TE8
switch or a 5TE1 disconnector, as the primary connecting leads
do not have to be interrupted.
The current transformer is designed for cables of up to 13 mm in
diameter, e.g. H07V-R with 50 mm2 conductor cross-section.

Technical specifications
7KT1 200

7KT1 201

7KT1 202

2.5

3.75

3 100

3 150

EN 60044-1

Standards
Secondary rated current strength

Accuracy class

Cl.

Rated power

VA

1.25

Rated frequency fn

Hz

50/60

60 Ie

Thermal continuous current

Short-time

1 Ie

Overcurrent limit factor

FS

Rated impulse withstand voltage Uimp

kV

>3

Creepage distances and clearances

mm

>3

Rated operational voltage Ue

V AC

720

Rated operational current Ie

A AC

3 60

Thermal current limit Ith

Terminals screw (Pozidriv)

PZ 1

Conductor cross-sections
- Rigid
- Flexible, with end sleeve
Permissible ambient temperature

mm2
mm2

0.5 ... 4
0.5 ... 2.5

-5 ... +60

Acc. to EN 60068-1

Resistance to climate

11

20/60/4

Selection and ordering data


Ue

Ie

Isec

Mount- DT
ing
width

V AC

A AC

A AC

MW

3 60
3 100
3 150

Order No.

Price
PU
PS*/
per PU (UNIT, P. unit
SET,
M)

PG

Weight
per PU
approx.
kg

Current transformers
720

B
B
B

7KT1 200
7KT1 201
7KT1 202

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.499
0.512
0.510

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

11/39

Siemens AG 2011

Measuring Devices and E-Counters


Accessories
7KT9 0 measuring selector switches

Overview

Benefits

Measuring selector switches are used as CO contacts of the


phases for voltages and currents in three-phase systems for voltmeters and ammeters.

The devices have a rated insulation voltage of 660 V. This permits use in many systems.

The design of these switches is adapted to match the modular


installation devices. They support use in compliance with
EN 60947-3.

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG Weight
per PU
approx.

V AC

A AC

V AC

MW

7KT9 010

1 1/48 units

027

0.126

7KT9 011

027

0.128

kg

Voltmeter selector switches


400

12

Ammeter selector switches for transformer


operation
400

12

1 unit

11

* You can order this quantity or a multiple thereof.

11/40

Siemens LV 10.1 2011

12

Siemens AG 2011

Monitoring Devices
12/2

Introduction

12/5

Transfer Switches
SENTRON Transfer Control Devices
for ATSE

12/9
12/11
12/15
12/17
12/18
12/19
12/20
12/21

Monitoring Devices for


Electrical Values
Residual current monitors
Voltage relays
Current relays
Priority switches
Fuse monitors
Phase and phase sequence monitors
Insulation monitors for industrial
applications
Monitoring of medical premises

12/29
12/31
12/32
12/33
12/35
12/36
12/38
12/40
12/41

Monitoring Devices for Plants and


Devices
GSM alarm modules
Fault signaling units
EMERGENCY STOP modules
Level relays
Line circuit relays
Dusk switches
Temperature controllers
P.f. controllers
Thermistor motor protection relays

12

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Introduction

Page

Field of application

Non-residential
buildings

Residential
buildings

Industry

Overview
Devices

Standards

Used in

12/5

The SENTRON ATC5300, equipped with IEC 60947-6-1


two motor-driven circuit breakers,
serves as a transfer system that automatically or manually switches between
two power supply systems in low-voltage power distribution applications.

Residual current monitors

12/9

To increase system availability and


IEC 62020;
operating safety through continuous
EN 62020
monitoring of residual current in electrical systems and alarms if a defined
threshold is exceeded.

--

Voltage relays

12/11

Monitoring the voltage of emergency


IEC 60255;
lighting in public buildings, short-time EN 50172
failures of 20 ms, for ensuring operational parameters for devices or system
components or monitoring the neutral
conductor for breaks.

--

Current relays

12/15

Monitoring of emergency and signal


lighting and motors.

--

Transfer switches
SENTRON transfer control devices
for ATSE

Monitoring devices for electrical values

12

IEC 60255

All current relays can be short-time


overloaded and connected either with
direct measurement or through transformers.

Priority switches

12/17

For a reduction of the connection fee in IEC 60669;


accordance with German Federal Reg- BTO 6 Section 4
ulations on Tariffs when used in systems
with electric storage heaters where the
continuous-flow heaters are switched
with priority.

--

--

Fuse monitors

12/18

Monitoring of all types of low-voltage


fuses.

--

Can be used in asymmetric systems


afflicted with harmonics and regenerative feedback motors.

12/2

Siemens LV 10.1 2011

IEC 60255

Siemens AG 2011

Monitoring Devices
Introduction
Standards

For the visual signaling of phase failures IEC 60255


or phase sequences in three-phase
systems.

Used in

Industry

Phase and phase sequence monitors 12/19

Field of application

Residential
buildings

Page

Non-residential
buildings

Devices

--

--

The phase sequence is arbitrary. The


device is also suitable for 1, 2 or
3-phase operation.

Insulation monitors for industrial


applications

12/20

To increase system availability and


IEC 60255;
operating safety through continuous
IEC 61557
monitoring of the isolation resistance in
ungrounded direct voltage or alternating voltage networks.

--

--

Monitoring of medical premises

12/21

For the insulation monitoring of a


medical IT system or the load current
monitoring of an IT system transformer
for a non-permissible temperature rise.

--

--

Mobile monitoring and switching of


plants worldwide by SMS for greater
safety and convenience. Plants can be
remotely switched and signals
received.

EN 61557-8;
IEC 61557-8;
DIN VDE 0100-710;
IEC 60364-7-710

Monitoring of the voltage supply with


automatic switchover.

Monitoring devices for plants and devices


GSM alarm modules

12/29

12

Fault signaling units

12/31

Evaluation and display of fault alarms


IEC 60255
and alarm signals for monitoring industrial plants and control systems.
With 4 inputs and connections for
39 expansion fault signaling units.

--

EMERGENCY STOP modules

12/32

For EMERGENCY-STOP switching in


accordance with the Directive 98/37/EC
on Safety of Machines. Safe types of
circuits for machines, plants or test
stations in industrial, commercial and
private enterprise applications.

--

Level relays

12/33

Control of liquid levels in containers with IEC 60255


3 electrode connections for 1-step and
2-step level control. High immunity to
interference of the measuring circuit
isolated from the system.

--

According to the
Directive 98/37/EC;
EN 954-1;
EN ISO 13849-1

Siemens LV 10.1 2011

12/3

Siemens AG 2011

Monitoring Devices

Page

Field of application

Standards

Used in
Non-residential
buildings

Residential
buildings

Industry

Introduction
Devices

Line circuit relays

12/35

For disconnecting the voltage or field


circuit of unused lines when loads are
disabled.

IEC 60255

--

--

Dusk switches

12/36

For demand-oriented switching of


lighting installations for shop windows
or paths in order to cut energy costs

EN 60730

--

Temperature controllers

12/38

For controlling and limiting temperaEN 60730


tures. Three adjustable ranges from
- 30 C to + 100 C. For PT 100 measuring element + 2 C to + 400 C.

P.f. controllers

12/40

For the monitoring of asynchronous


IEC 60255,
motors for underload and no-load oper- IEC 61557
ation, e.g. fan monitoring in the case of
V-belt breakage, filter blockages, pump
monitoring in the event of valve closure
or dry runs.

--

--

Thermistor motor protection relays

12/41

For the prevention of thermal motor


IEC 60255
overloads, e.g. due to high switching
frequency, single-phasing, disabled
cooling or excessive ambient temperatures.
With detection of wire breaks in the sensor circuit.

--

--

12

12/4

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Transfer Switches
SENTRON transfer control devices for ATSE

Overview
Mode of operation
The SENTRON ATC5300 controls the transfer between the main
and standby power supplies fully automatically, while talking into
consideration the set limit values and delay times. It detects
fluctuations occurring in the main power supply quickly and
switches to the standby power supply. The control device only
switches to the standby power supply after it has ensured that
the standby supply is delivering the required power supply quality. The devices switches back to the main power supply taking
into consideration the set parameters once the required power
supply quality is available again. If the standby power supply
and/or the main power supply is fed by a generator, the control
device also offers a wide range of settings, such as a generator
lead time, generator delay time, and generator start test at specified times.
The SENTRON ATC5300 can control air circuit breakers, compact molded case circuit breakers, switch disconnectors or contactors. The circuit breakers are controlled via the related motorized operating mechanisms.
Setting parameters and monitoring using
SENTRON ATC SOFTWARE
SENTRON ATC5300 network switchover controls

In addition to operation and parameterization on-site, you can


also monitor and set the parameters of the controller using the
SENTRON ATC software. The software offers a high level of convenience and quick access to all device settings, e.g. complex
settings which occur when connecting generators.

Automatic system transfer with the SENTRON ATC5300


The SENTRON ATC5300, equipped with two motor-driven circuit
breakers, serves as a transfer system that automatically or manually switches between two power supply systems in low-voltage
power distribution applications.

Measurement variables

In particular, the SENTRON ATC5300 is deployed everywhere


where a power failure is especially critical, e.g. in hospitals, in
conjunction with UPS systems, and for industrial processes.
Measured variables
Rated system voltage Un

V AC

The SENTRON ATC5300 records and monitors the following


measurement variables:

Default setting

Limit value setting

Delay time

Can be deactivated

100 ... 690

70 % ... 98 % (75 % ... 100 %) 1)

0.1 s ... 900 s

--

102 % ... 120 % (100 % ... 115 %) 1) 0.1 s ... 900 s

Voltage asymmetry

1 % ... 20 %

0.1 s ... 900 s

Phase failure

60 % ... 85 %

0.1 s ... 30 s

Left, right

--

--

50/60

80 % ... 100 %

0.1 s ... 900 s

101 % ... 120 %

0.1 s ... 900 s

70 % ... 100 %2)

0 ... 60 s

Direction of rotation
Frequency
Battery voltage Ub

Hz
V DC

12/24/48

110 % ... 140 %2)


1)

Hysteresis value for enabling back-transfer

2)

Warning only, no switching

12

yes
-- no

Siemens LV 10.1 2011

12/5

Siemens AG 2011

Monitoring Devices
Transfer Switches
SENTRON transfer control devices for ATSE

Benefits
The advantages of the SENTRON ATC5300 at a glance:
Controls compact molded case circuit breakers MCCB, air circuit breakers ACB, switch disconnectors LBS, or contactors
Two measuring inputs for single-phase and multi-phase power
supply systems
Option for switching between system to system, generator to
system, system to generator, and generator to generator
configurations
Direct measurement of three-phase industrial systems ranging up to 400 V ACL-N or 690 V ACL-L (converter costs, no
assembly and installation costs for converters)
Has two voltage supply units to cover all standard AC/DC voltage supplies, alternative supply via main and standby system
possible
Low space requirements due to door installation and compact
design
Two displays for monitoring the normal/standby system and
displaying the phase and interlinked cable voltages
Setting control parameters for generator activation requirements
Calendar clock

8 digital inputs, 6 of which are programmable and 7 relay outputs, 5 of which are programmable
4 selectable operating modes: off, manual, automatic, test
Data, parameter and logged events (e.g. power failure, faults)
remain accessible and unaltered even after a power failure or
restarting a device
Status display of the connected switches or contactors
Logging and statistical processing of occurring events
possible
Easy system integration through integrated MODBUS interface (RTU and ASCII) for integrating e.g. into a power
management system
The illuminated LED display makes reading measured values
and parameters easy, even under unfavorable lighting conditions
The SENTRON SOFTWARE ATC programming software saves
considerable time when setting parameters and setting up the
SENTRON ATC5300
Generator test run function for mandatory testing intervals
Command option for switching to the second set of protection
parameters in the ETU76B (air circuit breaker 3WL).

Integration

12

Implementation of an automatic transfer system

Q1 and Q2, configured with SENTRON circuit breakers

The SENTRON ATC5300 is used to automatically and manually


switch from a main power supply to a standby power supply and
vice versa. In case system faults occur, the SENTRON ATC5300
controls the switching operations fully automatically. This ensures a very high level of operational continuity.

All SENTRON circuit breakers connected to the SENTRON


ATC5300 must be equipped with the following accessories:
3VL circuit breakers MCCB
The following is also required for each MCCB:
- A motor drive
- An alarm switch
- Two auxiliary switches 1 NO/1 NC
3WL air circuit breakers ACB
The following is also required for each 3WL ACB:
- A motor drive
- A closing solenoid
- An auxiliary release (shunt release)
- Tripped signal switch
- One auxiliary switch block 2 NO/2 NC (standard fittings)

SENTRON ATC5300 allows the implementation of an automatic


transfer control unit in conjunction with compact molded case
circuit breakers MCCB, air circuit breakers ACB, switch disconnectors LBS, or contactors.
The following devices are ideally matched to the SENTRON
ATC5300:
SENTRON 3VL Molded Case Circuit Breakers
SENTRON 3WL Air circuit breakers
Component interaction
Feed-in system line 1 (main system) and line 2 (standby
system) are connected to SENTRON ATC5300.
In case of system anomalies, the SENTRON ATC5300 activates components Q1 and Q2 accordingly.
Q1 and Q2 can be implemented with compact molded case
circuit breakers MCCB, air circuit breakers ACB, switch disconnectors LBS, or contactors.

12/6

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Transfer Switches
SENTRON transfer control devices for ATSE

L1

LINE 1
L2 L3

L1

LINE 2
L2 L3

QF1

QF2

Q2

Q1

I202_01380
LOAD L1

L2

L3

Implementation of an automatic transfer system

Technical specifications
ATC5300

ATC5300
s

Auxiliary supply

Reversing time of control device

Rated voltage Un
AC
DC

Communication cables
V AC 220 ... 240
V DC 12 / 24 / 48

1200 ... 38400

Operating range
AC
DC

RS232 serial interface


bit/s
With programmable baud rate
Connection through RJ6/6 connector

V AC 187 ... 264


V DC 9 ... 70

RS485 serial interface


bit/s
Optically insulated
With programmable baud rate
Connection through plug-in terminals

1200 38400

Frequency

Hz

45 ... 65

Max. power consumption


at Un = 240 V AC

VA

Max. power loss


At 240 V AC
At 48 V DC

W
W

6.3
4.1

Max. current consumption


At 12 V DC
At 24 V DC
At 48 V DC

mA
mA
mA

300
180
90

Real-time clock
Energy storage

Safety in the event of short interruptions ms

50

Stored-energy capacitors

Operating time without feeding voltage Days Approx. 12 ... 15


Insulation voltage
Rated insulation voltage Ui

690

Operating temperature

-20 +60

Storage temperature

-30 +80

Measuring inputs

Relative humidity

<90

Max. rated voltage Un


Phase-phase
Phase-neutral

V AC 690
V AC 400

Max. pollution degree

Overvoltage category

Phase-phase measuring range

V AC 80 ... 800

Measuring category

CAT III

Frequency ranges

Hz

Measuring method
Measuring input impedance
Phase-phase
Phase-neutral

45 ... 65
RMS value (true RMS)

M
M

Connection method
Measuring errors

>1.1
>0.5

Connections
Terminal type

Removable/pluggable

Cable cross-section

mm2

0.2 ... 2.5 (24 ... 12 AWG)

Max. tightening torque

Nm

0.5 (4.5 lbfin)

Enclosure

Single-phase, two-phase, or
three-phase system

Enclosure material

Thermoplast LEXAN 3412R

0.25 %,
Value range 1 digit

Version

Door installation

Number of inputs

8, 6 of which are programmable

Type of input

Negative

Input current

mA

10

Input signal
Logic state "0"
Logic state "1"

V
V

1.5 (typical 2.9)


 5.3 (typical 4.3)

Input signal delay

ms

 50

IP41 front, IP20 rear

Degree of protection
Weight

Digital inputs

Contact configuration
2 relays with 1 NO contact
3 relays with 1 NO contact
2 relays with 1 CO contact

950

Certificates and conformity


ATS/ATSE standard

Complies with the ATS/ATSE


standard IEC 60947-6-1, in
combination with 3VL or
3WL1)

Environment classification

3K6 acc. to IEC 60721-3-3


3B2 acc. to IEC 60721-3-3
3C3 acc. to IEC 60721-3-3
3S2 acc. to IEC 60721-3-3

Relay outputs
Number of outputs

12

Ambient conditions

7, 5 of which are programmable

3M6 acc. to IEC 60721-3-3


1)

12 A, at 250 V AC (AC-1)
8 A, at 250 V AC (AC-1)
8 A, at 250 V AC (AC-1)

Acc. to IEC 60947-6-1

EMC
For more information see device manual at:
www.siemens.com/lowvoltage/manuals

Siemens LV 10.1 2011

12/7

Siemens AG 2011

Monitoring Devices
Transfer Switches
SENTRON transfer control devices for ATSE

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Screw terminals
SENTRON ATC5300
Control panel instrument 144 x 144 x 94 mm
with the following features:

3KC9 000-8TL30

1 unit

143

0.950

3KC9 000-8TL70

1 unit

143

0.300

Screw terminal connection


AC/DC power supply unit
220 240 V AC, 45 ... 60 Hz
9 ... 70 V DC
Rated setting range: 100 690 V AC
3KC9 000-8TL30
SENTRON SOFTWARE ATC
Software for setting parameters and remote control
operations, incl. connection cable from control
device to PC,
cable length 1.8 m
CD incl. software and manuals.

3KC9 000-8TL70

Minimum hard- and software requirements:


- Pentium, 64 MB RAM
- COM interface (serial RS232)
- CD drive
- Windows 95/98/2000/XP/Vista/Windows 7

12

* You can order this quantity or a multiple thereof.

12/8

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Residual current monitors

Overview
n

100 % n
Disconnection

Residual current

Plant safety and operating safety are becoming increasingly important alongside the protection of personnel. Shutdowns due to
the unexpected tripping of protective devices cause high costs.
It is possible to detect residual currents in the electrical installation before the protective device responds.
Residual current monitors (RCM) monitor residual current in
electrical installations and issue a signal when the residual current exceeds a set value.

50 %
Alarm

The summation current transformer detects all conductors required to conduct the current, i.e. including the neutral conductor where applicable. In a fault-free system, the magnetizing effects of the conductors through which current is flowing cancel
each other out for the summation current transformer, i.e. the
sum of all currents is zero. If a residual current is flowing due to
an insulation fault, a residual magnetic field is left in the core of
the transformer and produces a voltage. This voltage is evaluated using the electronics of the RCM. The switched contact can
be used e.g. to operate an acoustic/optical signaling device, a
higher-level control system or a circuit breaker.

I202_16044

RCMs are used primarily in plants where a fault should result in


a signal but not in disconnection. This enables plant operators to
detect faults and eliminate their causes before the protective
devices disconnect the installation, which increases plant and
operating safety and cuts costs.

Time t

Time characteristic of the rated residual current n

Benefits
Higher plant availability and operating safety through permanent monitoring of residual currents
Adjustable limit values for residual current and response time
enable timely detection and signaling plant shutdowns are
often avoidable
Devices for every application:
The summation current transformers are available in various
sizes, the RCMs can be used optionally for signaling and/or
switching
Additional fire protection can be implemented using the
monitoring system.

Technical specifications
RCM analog

RCM digital

RCM digital, 4 channels

EN 62020, IEC 62020

Standards
Rated operational voltage Ue
Frequency

V AC
Hz

230
50/60

Rated residual current n


Type A
Type AC

A
A

0.03 ... 3
3 ... 5

0.03 ... 3
3 ... 30

0.03 ... 3
3 ... 30

Response time tv

0.02 ... 5

0.02 ... 10, INS, SEL1)

0.02 ... 10, INS, SEL1)

1 alarm

1 alarm,
1 tripping operation
230
6

1 alarm,
4 tripping operation
230
6

--/Yes

Yes/Yes

Yes/Yes

Relay contacts
Rated voltage
Rated current

V AC
A

230
6

Summation current transformer

mm 

20 ... 210
Yes/Yes

Test/Reset
External tripping operation/external reset
Mounting width

MW

Degree of protection
Contacts
Front
Operating temperature
1)

12

IP20
IP41
C

-10 ... +50

INS: instantaneous, SEL: selective.

Siemens LV 10.1 2011

12/9

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Residual current monitors

Selection and ordering data


Rated operational voltage

Rated residual
current

Response
time

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

Ue

In

tv

V AC

MW

0.03 ... 3 (Type A)


3 ... 5 (Type AC)

0.02 ... 5

5SV8 000-6KK

1 unit

027

0.163

0.03 ... 3 (Type A)


3 ... 30 (Type AC)

0.02 ... 10,


INS, SEL1)

5SV8 001-6KK

1 unit

027

0.236

0.02 ... 10,


INS, SEL1)

5SV8 200-6KK

1 unit

027

0.236

Internal diameter

DT

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

kg

RCM analog
230, 50/60 Hz

RCM digital
230, 50/60 Hz

RCM digital, 4 channels


230, 50/60 Hz

1)

0.03 ... 3 (Type A)


3 ... 30 (Type AC)

INS: instantaneous, SEL: selective.

Order No.

12
mm

kg

Summation current transformer


Including holder for standard
mounting rail

20

5SV8 700-0KK

1 unit

027

0.076

30

5SV8 701-0KK

1 unit

027

0.095

Including holder for wall mounting1)

35
70
105

B
B
B

5SV8 702-0KK
5SV8 703-0KK
5SV8 704-0KK

1
1
1

1 unit
1 unit
1 unit

027
027
027

0.161
0.274
0.545

Including holder for wall mounting

140
210

B
B

5SV8 705-0KK
5SV8 706-0KK

1
1

1 unit
1 unit

027
027

1.222
2.040

5SV8 900-1KK

1 2 units

027

0.004

Holders for standard mounting rails


Suitable for summation current transformer with internal
diameter of 20 mm, 30 mm, 35 mm, 70 mm and 105 mm
1)

Mounting on standard mounting rail with optional holder for standard


mounting rail also possible.

* You can order this quantity or a multiple thereof.

12/10

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Voltage relays

Overview

Benefits
Complete voltage protection in a compact design for overvoltage and undervoltage monitoring in a single device
Plants and devices are reliably and easily protected by phasefailure relays
Overvoltages and consequential damage due to high voltages are prevented through N-conductor monitoring
Asymmetry monitoring in the voltage relay also protects threephase AC motors against operation with voltage skew.

Voltage relays are used for device and plant protection, supplying safety light devices and the detection of N-conductor breaks
and short-time voltage interruptions.
They are available as undervoltage, overvoltage and under/
overvoltage relays. The devices are equipped with different
functions, depending on their intended use, and comply with the
pertinent regulations.

Technical specifications
5TT3 400
5TT3 401
5TT3 402
5TT3 403
Rated control voltage Uc

V AC

230/400

Operating range (overload capability)

Uc

1.1

Hz

50/60

ON-switching
OFF-switching

Uc

0.9/0.95
0.7/0.85

V; mA

10; 100

Phase asymmetry

Setting accuracy
Repeat accuracy

%
%

---

Phase failure detection

At L1 or L2 or L3

ms

100

Rated frequency

Minimum contact load

5TT3 194

5TT3 195

400
1.35
4 % hysteresis
0.7 ... 0.95 0.9 ... 1.3
Approx. 5 ... 10
1

--

N-conductor monitoring
Between coil/contact

kV

Contacts

 contact (AC-11)

Electrical isolation

Creepage distances and


clearances
Actuator/contact

mm

5.5

Rated impulse withstand voltage Uimp

Actuator/contact

kV

> 2.5

>4

Terminals

screw (Pozidriv)

Conductor cross-sections
Rigid, max.
Flexible, with end sleeve, min.
Permissible ambient temperature

---

Approx. 5 ... 10
1

-Yes

Rated insulation voltage Ui

Resistance to climate

5TT3 406

IEC 60255; IEC 61810

Standards

Response values

5TT3 404
5TT3 405

--

1
mm2
mm2

2 2.5
0.5

-20 ... +60

Acc. to EN 60068-1

12

20/60/4
5TT3 196
IEC 60255; IEC 61810

Standards
Rated control voltage Uc

V AC

24

Rated power dissipation Pv


Coil/drive
Contact1) per pole

VA
VA

0.6
0.8

Hysteresis

Response values Uc
Undervoltage
Overvoltage

Undervoltage
Overvoltage

Residual ripple tripping Uc

Infinitely variable

0 ... 15

Overload capability

33 V DC
35 V DC
45 V DC

ms
ms

Continuous
500
10

mm

Input/output

kV

> 2.5

V/mA

24/300

AC-11
AC-1

A
A

1
4

Creepage distances and clearances


Rated impulse withstand voltage Uimp
Minimum contact load
Rated operational current Ie

0.82
1.18

 contact

Contacts
Electrical service life

In switching cycles at Ie

5 105

Terminals

screw (Pozidriv)

Conductor cross-sections
Rigid, max.
Flexible, with end sleeve, min.
Permissible ambient temperature
Resistance to climate
1)

Acc. to EN 60068-1

mm2
mm2

2 2.5
1 0.5

-20 ... +60


20/60/4

For rated operational current.

Siemens LV 10.1 2011

12/11

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Voltage relays
5TT3 407
Rated control voltage Uc

V AC

230/400

Operating range (overload capability)

Uc

1.1

Rated frequency

Hz

50/60

5TT3 410

1.35

1.2

Back-up fuse

Terminals L1/L2/L3

Response values

Overvoltage:
OFF-switching
ON-switching

Uc

---

0.9 ... 1.3


4 % hysteresis

---

Undervoltage:
OFF-switching
ON-switching

Uc

0.8
0.85

0.7 ... 1.1


4 % hysteresis

---

V; mA

10; 100

Setting accuracy

Approx. 5 ... 10

Repeat accuracy

At L1, L2 or L3

ms

 20

100

--

OFF delay

--

0.1 ... 20

--

Automatic reclosing delay

0.2 ... 20

--

--

Minimum contact load


Phase asymmetry
Phase failure detection

Rated insulation voltage Ui

Between coil/contact

kV

Contacts

 contact (AC-11)

Electrical isolation

Creepage distances and


clearances
Contact/contact
Actuator/contact

mm
mm

-4

-5.5

Rated impulse withstand voltage Uimp

Actuator/contact

kV

>4

Rated operational power Ps

AC operation:
230 V and p.f. = 1
230 V and p.f. = 0.4

VA
VA

2000
1250

---

---

DC operation:
Ue = 24 V and Ie = 6 A
Ue = 60 V and Ie = 1 A
Ue = 110 V and Ie = 0.6 A
Ue = 220 V and Ie = 0.5 A

W
W
W
W

max. 100
max. 100
max. 100
max. 100

-----

-----

screw (Pozidriv)

Terminals
Conductor cross-sections
Rigid, max.
Flexible, with end sleeve, min.
Permissible ambient temperature

12

5TT3 408

IEC 60255; IEC 61810

Standards

Humidity class

1
mm2
mm2

2 2.5
0.5

-20 ... +60

Acc. to IEC 60068-2-30

Voltage relays
5TT3 411

5TT3 412

Rated control voltage Uc

V AC

230

230/400

Overload capability

Uc

1.15

1.1

Rated frequency

Hz

50/60

Response values

ON-switching
OFF-switching

Minimum contact load


Phase failure detection

At L1, L2 or L3

2 % hysteresis

4 % hysteresis

Uc

0.9

0.9

V/mA

10/100

ms

--

100

--

Yes

N-conductor monitoring
Rated insulation voltage Ui

Between coil/contact

kV

AC-15 NO contacts

AC-15 NC contacts

Electrical service life in switching cycles

AC-15, 1 A, 230 V AC

5 105

Rated impulse withstand voltage

Acc. to IEC 60664-1

Contacts

kV

screw (Pozidriv)

Terminals

4
2

Pollution degree

Conductor cross-sections
Rigid
Flexible, with end sleeve
Permissible ambient temperature
Resistance to climate

12/12

Siemens LV 10.1 2011

Acc. to EN 60068-1

mm2
mm2

2 2.5
2 1.5

-20 +60
20/060/04

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Voltage relays

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Overvoltage relays
For the monitoring of 1, 2 or 3 phases against N,
switching thresholds:
0.9 ... 1.3 x Uc, 4 % hysteresis, adjustable
2 CO

230

230/400 AC 2

5TT3 194

1 unit

027

0.132

5TT3 195

1 unit

027

0.132

5TT3 196

1 unit

027

0.074

230/400 AC 1

5TT3 400

1 unit

027

0.081

5TT3 401

1 unit

027

0.079

5TT3 402

1 unit

027

0.126

5TT3 403

1 unit

027

0.126

5TT3 404

1 unit

027

0.130

5TT3 405

1 unit

027

0.128

5TT3 406

1 unit

027

0.131

For the monitoring of 3 phases against N,


with N-conductor monitoring,
switching thresholds:
0.9 ... 1.3 x Uc, 4 % hysteresis, adjustable
2 CO

230

230/400 AC 2

Direct voltage monitors


for monitoring a 24 V direct voltage network;
undervoltage Ufrom = 0.82
overvoltage Ufrom = 1.18
residual ripple 0 % ... 15 %, adjustable
1 NO and 1 NC

230

24 DC

Undervoltage relays
For the monitoring of 1, 2 or 3 phases against N,
with phase failure detection
Switching thresholds:
0.7 and 0.9 x Uc, not adjustable
1 CO

230

For the monitoring of safety light devices of 1, 2 or


3 phases against N,
with phase failure detection, switching
thresholds:
0.85 and 0.95 x Uc, not adjustable
1 CO

230

230/400 AC 1

For the monitoring of 1, 2 or 3 phases against N,


with phase failure detection
Switching thresholds:
0.7 and 0.9 x Uc, not adjustable
2 CO

230

230/400 AC 2

For the monitoring of 1, 2 or 3 phases against N,


with phase failure detection
Switching thresholds:
0.9 ... 0.95 x Uc, 5 % hysteresis, adjustable
2 CO

230

230/400 AC 2

For the monitoring of 3 phases against N, with


asymmetry, reverse voltage and phase failure
detection, with N-conductor monitoring, switching
thresholds:
0.7 and 0.9 x Uc, not adjustable
2 CO

230

230/400 AC 2

for monitoring of safety light devices of 3-phases


against N, with asymmetry, reverse voltage and
phase failure detection,
with N-conductor monitoring,
switching thresholds:
0.85 and 0.95 x Uc, not adjustable
2 CO

230

230/400 AC 2

For the monitoring of 3 phases against N,


with asymmetry, reverse voltage and
phase failure detection,
with N-conductor monitoring,
switching thresholds:
0.7 ... 0.95 x Uc, 5 % hysteresis, adjustable
2 CO

230

230/400 AC 2

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/13

12

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Voltage relays
Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Short-time relays
For the monitoring of short-time failure detection
 20 ms of 1, 2 or 3 phases against N,
with phase failure detection and
N-conductor monitoring,
switching thresholds:
0.8 ... 0.85 x Uc, not adjustable
2 CO

230

230/400

5TT3 407

1 unit

027

0.133

230/400

5TT3 408

1 unit

027

0.136

230/400

5TT3 410

1 unit

027

0.129

5TT3 411

1 unit

027

0.220

5TT3 412

1 unit

027

0.230

Under and overvoltage relays


For the monitoring of 3 phases against N,
with asymmetry, reverse voltage and phase failure
detection, with N-conductor monitoring and adjustable time delay of 0.1 ... 20 s,
switching thresholds:
Undervoltage:
0.7 ... 1.1 x Uc, 4 % hysteresis, adjustable
overvoltage:
0.9 ... 1.3 x Uc, 4 % hysteresis, adjustable
2 CO

230

N conductor monitors
with asymmetry detection and
N-conductor monitoring
2 CO

230

Voltage relays for undervoltage monitoring of


medical premises
Single-phase against N with test button,
switching thresholds: 0.9 Un, 2 % hysteresis
2 NO + 2 NC

12

230

230

Single, two or three-phase against N,


with asymmetry, reverse voltage and phase failure
detection, with N-conductor monitoring, and one
test button each for the phases, switching thresholds: 0.9 Un, 4 % hysteresis
1 CO, 1 NO, 1 NC 230

230/400

* You can order this quantity or a multiple thereof.

12/14

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Current relays

Overview

Benefits
Devices with an extremely broad range of applications of minimum 0.1 A to maximum 15 A without transformer
Permanent overload capability up to 20 A or 30 A max. for up
to 3 seconds, protect the function against uncontrolled plant
states and increase plant availability
Range changing enables the precise setting of current values
through a high resolution
Ultra compact current relays require only the smallest of
spaces and save costs

Current relays monitor single and three-phase systems for the


flow of current, e.g. in emergency lighting installations, and the
loading of motors. They are available as undercurrent, overcurrent and under/overcurrent relays.

Technical specifications
Standards
Rated control current Ic
Rated control voltage Uc
Primary operating range
Overload capability, continuous
Overload capability, short-time

At 50 C ambient temperature max. 3 s

A
V AC
Uc
A
A

5TT6 111
IEC 60255; DIN VDE 0435-303
1 ... 10
230
0.9 ... 1.1
15
20

5TT6 112

Hz

50/60
Infinitely variable
permanent, 4 % hysteresis

Infinitely adjustable
Non-adjustable

s
ms

0.1 ... 20
Current corresponds to the rated operational power of the continuous-flow heater

Between coil/contact

V; mA
kV

10; 100
2.5

NO contacts
NC contacts

A
A

3
1

Electrical isolation

Creepage distances and


clearances
actuator/contact

mm

Rated impulse withstand voltage Uimp


Terminals
Conductor cross-sections

Actuator/contact
screw (Pozidriv)
Rigid
Flexible, with end sleeve

kV

Rated frequency
Response values
Switching delay tv
Response time
Minimum contact load
Rated insulation voltage Ui
Contacts
 contact (AC-15)

Permissible ambient temperature


Resistance to climate

ON-switching
OFF-switching

>4
1
max. mm2 2 2.5
2
min. mm 1 0.5

C
Acc. to EN 60068-1

12

-20 ... +60


20/60/4
5TT6 113

5TT6 114

5TT6 115

A
A
A
A

4 ranges
0.1 ... 1
0.5 ... 5
1 ... 10
1.5 ... 15

Rated control voltage Uc

V AC

230

Primary operating range


Overload capability, continuous
Overload capability independent of measuring range max. 3 s

Uc
A
A

0.9 ... 1.1


20
30

Rated frequency

Hz

50/60

Rated control current Ic

1 range
0.5 ... 5

15

Response values

ON-switching
OFF-switching

Switching delay tv

Infinitely adjustable

0.1 ... 20

Response time

Non-adjustable

ms

see: www.siemens.com/lowvoltage/manuals

V; mA

10; 100

Between coil/contact

kV

2.5

NO contacts
NC contacts

A
A

5
1

Creepage distances and


clearances
actuator/contact

mm

Rated impulse withstand voltage Uimp

Actuator/contact

kV

>4

Terminals

screw (Pozidriv)

Conductor cross-sections

Rigid
Flexible, with end sleeve

Minimum contact load


Rated insulation voltage Ui
Contacts
 contact (AC-15)
Electrical isolation

Infinitely variable
Permanent, 4 % hysteresis

1
max. mm2 2 2.5
min. mm2 1 0.5
C

Permissible ambient temperature


Resistance to climate

5TT6 120

IEC 60255; DIN VDE 0435-303

Standards

Acc. to EN 60068-1

-20 ... +60


20/60/4

Siemens LV 10.1 2011

12/15

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Current relays

Selection and ordering data


Contacts

Ue

Ie

Measuring
range

Mount- DT
ing
width

V AC

A AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Current relays for single-phase loads up to 230 V AC,


auxiliary voltage and measuring circuit, not isolated
Undervoltage monitoring, single-phase
1 CO

230

1 ... 10

5TT6 111

1 unit

027

0.084

5TT6 112

1 unit

027

0.080

5TT6 113

1 unit

027

0.152

5TT6 114

1 unit

027

0.148

5TT6 115

1 unit

027

0.154

5TT6 120

1 unit

027

0.245

Overcurrent monitoring, single-phase


1 CO

230

1 ... 10

Current relays for single-phase loads up to 230 V AC,


auxiliary voltage and measuring circuit,
galvanically isolated
Undervoltage monitoring, single-phase
2 CO

230

4 ranges
0.1 ... 1
0.5 ... 5
1 ... 10
1.5 ... 15

Overcurrent monitoring, single-phase


2 CO

230

4 ranges
0.1 ... 1
0.5 ... 5
1 ... 10
1.5 ... 15

Over/undervoltage monitoring, single-phase


2 CO

230

4 ranges
0.1 ... 1
0.5 ... 5
1 ... 10
1.5 ... 15

Current relays for three-phase loads for 3 400 V AC,


separate signal with N-wire connection
Over/undervoltage monitoring, three-phase

12

2 CO each for
overcurrent/
undercurrent
respectively

230

0.5 ... 5

* You can order this quantity or a multiple thereof.

12/16

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Priority switches

Overview

Benefits

In the mixed operation of electric hot water and electric storage


heaters, the priority switch interrupts the charging procedure of
the storage heater if hot water is required during the low-tariff
time, thus limiting the connected load in compliance with
BTO 6. The control circuit terminals must be sealable.

Reduction of the connection fee, which depends on the maximum load to be supplied (BTO, German Federal Regulation on
Tariffs 6 Section 4), when used in systems with continuous-flow
heaters and electric storage heaters where the continuous-flow
heaters are switched with priority.

Technical specifications
5TT6 101

5TT6 102

5TT6 103

EN 60669, BTO 6 Section 4

Standards
Rated control current Ic

40
54
6 ... 40
(Current corresponds to the rated operational power of the
continuous-flow heater).

Rated frequency

Hz

50

Response currents

13
23
(Continuous rise not permissible)

kW
kW

9
27

1.5 ... 9
4.5 ... 27

Rated impulse withstand voltage Uimp

kV

> 2.5

Rated operational voltage Ue

V AC

250

Rated operational power


For continuous-flow heaters

Up to
230 V AC
Up to 3 230 V AC

Rated operational current Ie

At Ue =

230 V AC

Terminals

screw (Pozidriv)

Conductor cross-sections
Coil
Contacts

For conductor cross-sections up to mm2


For conductor cross-sections up to mm2

10
2 2.5

Permissible ambient temperature


Acc. to DIN 50016

Resistance to climate

12
36

-20 ... +40


FW 24

Selection and ordering data


Ue

Ie

Response
currents

Mount- DT
ing
width

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Priority switches
For continuous-flow heaters up to 27 kW
230

40

5TT6 101

1 unit

027

0.113

23

5TT6 102

1 unit

027

0.092

6 ... 40

5TT6 103

1 unit

027

0.113

13

For continuous-flow heaters up to 33 kW


230

54

For electronically controlled


continuous-flow heaters up to 27 kW
230

40

5TT6 101

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/17

12

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Fuse monitors

Overview

Benefits
Increase in plant availability, because fuse failures which
could cause considerable damage to the plant are detected
in plenty of time.
A fuse failure is detected even if the load is switched off. This
ensures the highest level of plant availability.

Fuse monitors serve to monitor all types and versions of melting


fuses that cannot be equipped with a fault signal contact. This
enables integration in fault signaling circuits or a central alarm in
order to improve plant availability.

Technical specifications
5TT3 170
IEC 60255; IEC 61810

Standards
Rated control voltage Uc

3 AC 380 ... 415

Primary operating range

Uc

0.8 ... 1.1

Rated frequency

Hz

50 ... 400

Internal resistance of measuring paths

/V

> 1000

Max. permissible rear feed

90

Response/release time

ms

< 50

Rated impulse withstand voltage Uimp


Input/output

kV

>4

V AC

250

Rated operational current Ie

AC-1

Electrical service life

AC-11

in switching cycles at 1 A

1.5 105

Terminals

screw (Pozidriv)

Conductor cross-sections

Rigid, max.
Flexible, with end sleeve, min.

Rated operational voltage Ue

Permissible ambient temperature

mm2
mm2

2 2.5
1 0.5

-20 ... +45

Acc. to EN 60068-1

Resistance to climate

20/45/4

Selection and ordering data

12

Ue

Ie

Uc

Mount- DT
ing
width

V AC

3 V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Fuse monitors
For all low-voltage fuse systems. Can be used in
asymmetric systems afflicted with harmonics and
regenerative feedback motors. Signal also for disconnected loads.
230

380 ... 415

5TT3 170

1 unit

027

0.153

* You can order this quantity or a multiple thereof.

12/18

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Phase and phase sequence monitors

Overview

Benefits

Phase monitors monitor the voltages in three-phase system and


signal the power failure of one or more phases over a floating
contact. Phase sequence monitors monitor the phase sequence
in three-phase systems and signal any changes in the phase sequence change of rotating field over a floating changeover
contact.

The three-phase LED display in the phase monitor and the


LED display in the phase sequence monitors provide constant
information on the switching state of the plant
The compact design in 1 MW saves space.

Technical specifications
5TT3 421

5TT3 423

IEC 60255; IEC 61810

Standards
Rated control voltage Uc

V AC

230/400

Primary operating range

Uc

0.8 ... 1.1

Hz

50/60

VA
VA

9
0.2

Rated operational voltage Ue

V AC

250

Rated operational current Ie

Minimum contact load

V; mA

10; 100

Rated frequency
Electronics
Contacts

Rated power dissipation Pv

Rated insulation voltage Ui

Between coil/contact

kV

Contacts

 contact (AC-11)

Electrical isolation

Creepage distances and


clearances
Actuator/contact

mm

Rated impulse withstand voltage Uimp

Actuator/contact

kV

> 2.5

Terminals

screw (Pozidriv)

Conductor cross-sections

Rigid, max.
Flexible, with end sleeve, min.

Degree of protection

Acc. to EN 60529

Safety class

Acc. to EN 61140

1
mm2
mm2

2 2.5

IP20, with connected conductors


II

Permissible ambient temperature


Acc. to EN 60068-1

Resistance to climate

400

-20 ... +60


20/60/4

12

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

V AC

MW

230/400

5TT3 421

1 unit

027

0.080

5TT3 423

1 unit

027

0.080

kg

Phase monitors
With 3 green LEDs for 3 phases
1 CO

250

Phase sequence monitors


With one green LED, which lights up for rightrotating field
1 CO

250

400

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/19

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Insulation monitors for industrial applications

Overview
Insulation monitors are used for protection of persons and
against fire in non-grounded systems (IT systems). The insulation resistance of the system being monitored is measured
against ground.

These types of measurements are specified according to


DIN VDE 0100-410 Low-voltage electrical installations
Protection against electric shock (similar to IEC 60364-4-41).

Technical specifications
5TT3 470

5TT3 471

V AC
V DC

220 ... 240


--

---

Uc
V DC

0.8 ... 1.1


--

---

Frequency range for Uc

Hz

45 ... 400

--

Rated power dissipation Pv

For DC supply

VA
W

Approx. 2
--

-Approx. 1

Terminals A1 to A2
Terminals L to PU
Terminals A1, A2 to L, PU
Terminals against contacts

kV
kV
kV
kV

<4
<4
<4
<6

<4
<4
<3
<6

For direct voltage and alternating voltage networks

For direct voltage systems

Power supply Uc
With AC supply
For DC supply

Primary operating range

Rated impulse withstand voltage Uimp

Measuring circuit

12

Measurement voltage range Umeas

V AC
V DC

0 ... 500
--

-12 ... 280

Primary operating range

Umeas 0 ... 1.1

0.9 ... 1.1

Frequency range for Umeas

Hz

10 ... 1000

--

k

5 ... 100

5 ... 200

Infinitely variable

Infinitely variable

Alarm values

Measuring shunt RAL

Setting of alarm value

On absolute scale

Alternating current internal resistance

Internal testing resistor

k

> 250

--

Direct current internal resistance

Internal testing resistor


L+ and L- to PU

k
k

> 250
--

-75 each

Measurement voltage Umeas

Internal

V DC

Approx. 15

--

Max. measurement current Imeas

Short circuit

mA

< 0.1

0.2 ... 4 depending on the


voltage

Direct interference voltage

Max. permissible

V DC

500

--

Response delay

At RAL 50 k and 1 F
and  up to 0.9 x Rmeas
and Rmeas from  to 0 

s
s

< 1.3
< 0.7

0.8
0.4

Switching hysteresis

At Rmeas 50 k

15

10 ... 15

Contacts

 contact

2 CO

2 CO

V AC

230

230

A
A
A
A
A
A

4
---5
2

4
2
0.2
3
---

Rated operational voltage Ue


Thermal current limit Ith
DC-13 at 24 V DC
DC-13 at 250 V DC
AC-15
AC-15 NO contacts
AC-15 NC contacts

Rated operational current Is

Terminals

screw (Pozidriv)

Conductor cross-sections

Rigid, max.
Flexible, with end sleeve, min.

Permissible ambient temperature

mm2
mm2

2 2.5
1 0.50

-20 ... +60

Degree of protection

Terminals (acc. to EN 60529)


Enclosure (acc. to EN 60529)

IP20
IP40

Resistance to climate

Acc. to EN 60068-1

20/060/04

Selection and ordering data


Contacts

Uc

Ue

Measuring
range

Mount- DT
ing
width

V AC

k

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Insulation monitors
For monitoring the insulation resistance in non-grounded
three-phase and single-phase AC networks
from 10 ... 1000 Hz against ground
2 CO

230

0 ... 500 V AC 5 ... 100

5TT3 470

1 unit

027

0.184

5TT3 471

1 unit

027

0.149

For monitoring the insulation resistance in non-grounded


DC systems against ground
2 CO

--

12 ... 280 V DC 5 ... 200

* You can order this quantity or a multiple thereof.

12/20

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises

Overview

Benefits

In areas that conform to Group 2 of DIN VDE 0100-710, any interruption to the examination and/or treatment of patients would
place those patients at risk.
Limit monitoring
This is prevented through the use of changeover and monitoring
units. These monitor the insulation resistance of the nongrounded IT system, the load current and the temperature of the
transformer. If the limit value is exceeded, the insulation monitor
gives out a warning signal.

TV-certified switchover device with increased functionality


Plant state signal over contacts No specific manufacturer's
bus system
Easy operation over potentiometers as the set limit value is
always visible
Easy to integrate in existing plants, including plants from other
manufacturers.

Voltage monitoring
In addition, a special voltage relay monitors the voltage of the
power supply and switches to a second power supply if it falls
below the specified limit values.

Technical specifications
Switchover device
7LQ3 361

7LQ3 362

IEC 60364-7-710; DIN VDE 0100-710

Standards
Power supply Uv

V AC

230

Primary operating range

Uv

0.9 1.1

Supply frequency fv

Hz

50 60

230/400

IEC 60664-1

Insulation coordination
kV

Rated impulse withstand voltage

4
3

Pollution degree
W

Power loss max. Pv

10.7

Power section
Mechanically latched; mechanically and electrically locked

Contactors
Rated operational current acc. to DIN VDE 0100-710

51

32

Rated operational current AC-3

113

71

Short-circuit protection acc. to DIN VDE 0100-710


Max. backup protection
gG

63

Switchover time

0.1 ... 10

k

50

12

Measuring circuit insulation monitoring


Response value Rresp

DIN VDE 61557-8

Response deviation
RF from  to 0.5 Rto
RF from  to 0 k

s
s

< 1.3
< 0.7

Hysteresis

15

Measurement voltage Um

V DC

Approx. 15

Measurement current Im max (at RF = 0 )

< 50

Internal resistance DC Ri

k

> 250

Impedance Zi at 50 Hz

k

> 250

Permissible direct interference voltage Ufg

V DC

< 300

Response time ton at Ron = 50 k, Ce = 1 F

External/internal

Test button

Measuring circuit load current monitoring


Response value,
adjustable with external transformer 50/5 A, Class 1

5 50

Hysteresis

Temperature influence

%/C

 0.05

Time delay tv, adjustable

0.1 20

Response value

k

3.2 3.8

Release value

k

1.5 1.8

Measuring circuit temperature monitoring

PTC thermistor

Acc. to DIN 44081/44082 Unit(s)

1 6 in series

ON-switching
OFF-switching

Uc

2 % hysteresis
0.9

4 % hysteresis
0.9

At L1, L2 or L3

ms

--

100

--

Yes

Measuring circuit, voltage monitoring


Response values
Phase failure detection
N-conductor monitoring

Siemens LV 10.1 2011

12/21

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises
Switchover device
7LQ3 361

7LQ3 362

Connection
Terminals
Load circuit

Feeder terminals
Output terminals

mm

4 ... 16

Communication

Status signals
Fault indications

mm

2.5

-20 ... 45

Environmental conditions
Permissible ambient temperature

Vertical

Mounting position

Insulation monitors
7LQ3 354

7LQ3 355

EN 61557-8

Standards
Power supply Uv

V AC

230

Primary operating range

Uv

0.9 1.1

Supply frequency fv

Hz

50 60

Power loss max. Pv

VA

Approx. 7

Rated system voltage Un (measuring circuit)

V AC

0 300

Rated frequency fn

Hz

10 1000

EMC immunity to interference

IEC 61000-6-2

EMC emitted interference

IEC 61000-6-3
IEC 60664-1

Insulation coordination
kV

Rated impulse withstand voltage

Pollution degree

Flammability class

UL 94V-0

Measuring circuit insulation monitoring


k

Response value Rresp


RF from  to 0.5 Ron
RF from  to 0 k

s
s

< 1.3
< 0.7

Hysteresis

15

Measurement voltage Um

V DC

Approx. 15

Measurement current Im max (at RF = 0 )

< 50

Internal resistance DC Ri

k

> 250

Impedance Zi at 50 Hz

k

> 250

Permissible direct interference voltage Ufg

V DC

< 300

Response value,
adjustable with external transformer 50/5 A, Class 1

5 50

Hysteresis

Temperature influence

%/C

 0.05

Time delay tv, adjustable

0.1 20

Response value

k

3.2 3.8

Release value

k

1.5 1.8

Response time ton at Ron = 50 k, Ce = 1 F

12

50

50 ... 500

EN 61557-8

Response deviation

Measuring circuit load current monitoring

Measuring circuit temperature monitoring

PTC thermistor

Acc. to DIN 44081/44082 Unit(s)

1 6 in series

Display and control elements


Operating error

Acc. to IEC 61557-8

LED display

Current and temperature monitoring


Ready-to-run
Insulation fault
Line breakage monitoring of the isolation measuring circuit

One red and one green LED


Green
Red
Red

Display of current insulation resistance

--

Pushbuttons

Test and Reset

12/22

Siemens LV 10.1 2011

11-step LED chain

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises
Insulation monitors
7LQ3 354

7LQ3 355

Output relay
Contacts for

Overtemperature
Overload
Insulation fault

2 CO
2 CO
2 CO
Working current

Mode of operation
Contacts

AC-15 NO contacts
AC-15 NC contacts

A AC/V AC
A AC/V AC

3/230
1/230

Electrical service life

AC-15, 1 A, 230 V AC

Switching
cycles

30000

A AC

Thermal current

Connection
Terminals

screw (Pozidriv)

Conductor cross-sections
Insulation fault

Rigid
Flexible, with end sleeve

2
mm2
mm2

2 2.5
1 2.5

-20 +60

Environmental conditions
Permissible ambient temperature
Resistance to climate

Acc. to EN 60068-1

20/060/04

Degree of protection

Acc. to EN 60529

IP20, with connected conductors


any

Mounting position
Vibration strain
Amplitude
Frequency

Acc. to IEC 60068-2-6


mm
Hz

0.35
10 55

Test and signaling panels


7LQ3 356
V AC/DC

24

kV

Voltage range

AC
DC

0.8 ... 1.1 x Un


0.9 ... 1.2 x Un

Rated current per input

mA

0.25

Rated consumption

VA

Rated voltage Un
Rated impulse withstand voltage

7LQ3 357

DIN VDE 0100-710; IEC 60364-7-710

Standards
Acc. to IEC 60664-1

Continuous operation

Rated operating mode


Pollution degree

Acc. to IEC 60664-1

Degree of protection
Enclosures
Terminals

Acc. to IEC/EN 60529


Acc. to IEC/EN 60529

IP40
IP20

12

UL 94V-0

Flammability class
Vibration strain
Amplitude
Frequency

Acc. to IEC/EN 60068-2-6

Resistance to climate

Acc. to IEC/EN 60068-1

mm
Hz

0.35
10 55
20/045/04
EN 50005

Terminal marking
Conductor connections
Solid

mm2
mm2

1 1.5
2 0.5

Strand

mm2
mm2

11
2 0.2

Strand with sleeve

mm2

1 0.5
Box terminals with wire protection

Conductor mounting
Device dimensions

mm

80 160 57

Temperature range

-20 ... +45

82 150 57

Siemens LV 10.1 2011

12/23

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises
Current transformer Class 1
7LQ3 358
IEC/EN 60044-1

Standards
Rated control voltage Uc

V AC

230

Rated frequency

Hz

50/60

kV

Rated transmission ratio kn

50/5

Primary rated current

50

Secondary rated current

Rated power

V/A

1.5

50 Hz, 1 min

Test voltage

Class
Rated frequency

Hz

50 ... 60

Highest voltage at equipment / insulation level

kV

0.72/3

Overcurrent factor
Thermal rated short-time current
Thermal rated continuous current

In
In

FS5
60
1.2

Expanded current range

120

Permissible ambient temperature

-20 +60

Test and signaling combination for insulation monitors


7LQ3 360
DIN VDE 0100-710; IEC 60364-7-710

Standards
Rated voltage Un

V AC

24

Voltage range

AC

0.8 ... 1.1 Un

Connected load

0.5
Continuous operation

Rated operating mode


EMC
Static discharge
RF irradiation
Rapid transients
Surge voltage (surge)

Acc. to IEC/EN 61000-4-2


Acc. to IEC/EN 61000-4-3
Acc. to IEC/EN 61000-4-4
Acc. to IEC/EN 61000-4-5

kV
V/m
kV
kV

IP30

Degree of protection

12

8 (air discharge)
10
2
1

Amplitude

mm

0.35

Frequency

Hz

10 ... 55

Temperature range

-5 ... +55

Resistance to climate

Acc. to IEC/EN 60068-1

05/055/04
EN 50005

Terminal marking
Conductor connections
Solid
Strand with sleeve and plastic collar
Strand with sleeve and plastic collar
Strand with sleeve

DIN 46228-1/-2/-3/-4
DIN 46228-1/-2/-3

mm2
mm2
mm2
2

mm

Box terminals with wire protection

Conductor mounting
Device dimensions

12/24

Siemens LV 10.1 2011

14
1 2.5
2 1.5
2 2.5

mm

80 80 35

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises
Voltage relays
5TT3 411

5TT3 412

Rated control voltage Uc

V AC

230

230/400

Overload capability

Uc

1.15

1.1

Rated frequency

Hz

50/60

ON-switching
OFF-switching

Uc

2 % hysteresis
0.9

V/mA

10/100

At L1, L2 or L3

ms

--

100

--

Yes

Response values
Minimum contact load
Phase failure detection
N-conductor monitoring
Rated insulation voltage Ui

Between coil/contact

kV

Contacts

AC-15 NO contacts
AC-15 NC contacts

3
2

Electrical service life in switching cycles

AC-15, 1 A, 230 V AC

5 105

Rated impulse withstand voltage

Acc. to IEC 60664-1

kV

screw (Pozidriv)

Conductor cross-sections
Rigid
Flexible, with end sleeve
Permissible ambient temperature
Resistance to climate

4
3
1

4
2

Pollution degree
Terminals

4 % hysteresis
0.9

2
mm2
mm2

2 2.5
2 1.5

-20 +60

Acc. to EN 60068-1

20/060/04

IT line transformer
4AT3/4AT4
In the case of isolating transformers used to set up medical IT systems,
overcurrent protective devices are only permissible as protection against
short circuits. To protect the isolating transformers against overload they
are fitted with monitoring devices that signal an excessive rise in temperature (e.g. 7LQ3 354 insulation monitors).
Standards

EN 61558-2-15

Safety class

Static shield between primary and secondary winding

with insulated connection

Thermistor transformer protection

Warning in the event of thermal overload1)


With center tap

Insulation monitoring
Short-circuit voltage Uz

3

No-load supply current I0


Starting current (rush), max.

%
x I1N

3
8

Rated ambient temperature ta /Thermal Class


1)

12

55 C/H

Tripping units must be ordered separately.

Siemens LV 10.1 2011

12/25

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises

Selection and ordering data


Version

Ue

Ie

Uc

Mount- DT
ing
width

V AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Switchover device according to VDE 0100-710


for medical premises
2-pole,
for medical premises of Group 2,
for switching over two redundant supply leads,
monitoring of IT system and the IT line transformer,
up to 8 kVA
230

51

230

7LQ3 361

1 unit

027

17.500

230/400

7LQ3 362

1 unit

027

17.500

7LQ3 354

1 unit

027

0.396

7LQ3 355

1 unit

027

0.600

Surface mounting

7LQ3 356

1 unit

027

0.325

Flush mounting

7LQ3 357

1 unit

027

0.220

4-pole, for use with symmetric loads


230

32

Insulation monitors
With load current and temperature monitoring for medical
premises
230

With load current and temperature monitoring of medical


premises with adjustable response value of 50 500 k
and output for 7LQ3 360 test and signaling combination
230

12

Test and signaling panels


For switchover devices,
24 V AC/DC, 50/60 Hz

* You can order this quantity or a multiple thereof.

12/26

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises
Version

Ue

Ie

Uc

Mount- DT
ing
width

V AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Test and signaling combination for insulation


monitors
24 V AC 50/60 Hz

7LQ3 360

1 unit

027

0.105

7LQ3 358

1 unit

027

0.390

5TT3 411

1 unit

027

0.220

5TT3 412

1 unit

027

0.230

Current transformer 50A/5A AC Class 1


With base angle
230

Voltage relays for undervoltage monitoring of medical


premises
Single-phase against N with test button,
switching thresholds: 0.9 Un, 2 % hysteresis
2 NO + 2 NC

230

230

Single, two or three-phase against N,


with asymmetry, reverse voltage and phase failure
detection, with N-conductor monitoring,
and one test button each for the phases,
switching thresholds: 0.9 Un, 4 % hysteresis
1 CO, 1 NO, 1 NC

230

230/400 4

Accessories
SIRIUS 4AT isolating transformers
Further information about the SIRIUS 4AT isolating transformers
can be found in the catalog IC 10 2011.

12
Rated
Voltage rise Rated voltages
power Pn during
no-load
operation uA

kVA

DT1) Order No.

Short-circuit protection for the


transformer

Input
U1N

Output
U2N

With fuse, With circuit breaker


gG opera- Type
Set
tional
value
class

PU
PS*/
(UNIT, P. unit
SET,
M)

PG

Cu
weight
per PU
approx.

Weight
per PU
approx.

kg

kg

Isolating transformer
Degree of protection IP00
2.5
3.15
4

3.6
3.6
3.6

230
230
230

230-115
230-115
230-115

35
35
50

3RV20 21-4CA10
3RV10 31-4EA10
3RV10 31-4EA10

21
26
29

C
C
C

4AT30 12-1TA71-3MA0
4AT36 02-1TA71-3MA0
4AT36 12-1TA71-3MA0

1
1
1

1 unit 104
1 unit 104
1 unit 104

7.400
6.800
9.400

25.500
33.000
36.000

5
6.3
8

3.6
3.6
3.7

230
230
230

230-115
230-115
230-115

50
63
63

3RV10 31-4FA10 36
3RV10 31-4GA10 40
3RV10 41-4JA10 49

C
C
C

4AT39 02-1TA71-3MA0
4AT39 12-1TA71-3MA0
4AT43 02-1TA71-3MA0

1
1
1

1 unit 104
1 unit 104
1 unit 104

9.700
13.800
12.600

45.000
49.000
63.000

Degree of protection IP23


2.5
3.15
4

3.6
3.6
3.7

230
230
230

230-115
230-115
230-115

35
35
50

3RV20 21-4CA10
3RV10 31-4EA10
3RV10 31-4EA10

21
26
29

C
C
D

4AT30 12-1TA71-3MC0
4AT36 02-1TA71-3MC0
4AT36 12-1TA71-3MC0

1
1
1

1 unit 104
1 unit 104
1 unit 104

7.400
6.800
9.400

33.200
50.000
44.000

5
6.3
8

3.6
3.9
3.7

230
230
230

230-115
230-115
230-115

50
63
63

3RV10 31-4FA10 36
3RV10 31-4GA10 40
3RV10 41-4JA10 49

C
C
C

4AT39 02-1TA71-3MC0
4AT39 12-1TA71-3MC0
4AT43 02-1TA71-3MC0

1
1
1

1 unit 104
1 unit 104
1 unit 104

9.700
13.800
12.400

59.000
63.000
77.000

1)

Delivery time depends on the number of units ordered, the specified


delivery time applies to an order quantity of up to 5 units.

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/27

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Electrical Values
Monitoring of medical premises

More information
TV-certified switchover device
The 7LQ3 361 and 7LQ3 362 switchover devices have been
tested and certified by TV Rhineland. Switchover devices
comply with DIN VDE 0100-710:2002-11 and
IEC 60364-7-710:2002-11.

12

Rhineland TV certificate for 7LQ3 361 and 7LQ3 362 switchover


devices

12/28

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
GSM alarm modules

Overview

Benefits

The GSM alarm module (GSM = Global System for Mobile Communications) enables cost-effective remote control of industrial
and private building management, e.g. of heating, air-conditioning and cooling systems. But it is also possible to safely control
elevators and escalators and all kinds of production equipment,
such as machines, automatic devices and conveyor belts. The
GSM alarm module is particularly suitable for distant plants,
such as monitoring the heating of summer houses or the pumps
of a water treatment plant.
Using voltage relays, current relays, fuse monitors, miniature circuit breakers, residual current operated circuit breakers or surge
arresters fitted with auxiliary switches or signal contacts, there
are virtually no limits to the type of monitoring tasks that can be
carried out. The use of remote controlled mechanisms with miniature circuit breakers and residual current operated circuit
breakers also allows realization of a range of cost-effective and
interesting solutions.

Mobile monitoring and control of electrical plants and system


components
Fast and reliable alarm signaling over SMS
Simple operation and parameterization over SMS
Saves space and can be retrofitted in any plant
1 administrator telephone number from any mobile network for
configuration
Transmission of alarm messages to up to 5 cell phones
Customized tests for 2 alarm inputs and switchable output.

Note:
Since the availability of mobile networks cannot be guaranteed,
GSM alarm modules should not be used for safety-relevant control functions.

Technical specifications
5TT7 120-0
Rated power Ps

4.5

Digital inputs

V DC

24; 2-wire connection, isolated

Signal voltage "0" at the input

V DC

-2 ... 2

Signal voltage "1" at the input

V DC

8 ... 30

V; A

250; 5

Maximum contact load

V; A

30; 5

Rated operational voltage Ue

V DC

10 ... 30

Permissible residual ripple


- At 10 V
- At 30 V

%
%

<1
< 10

Maximum contact load

At p.f. = 1

Vibration resistance

Acc. to EN 60068-2-34

1 at 10 ... 500 Hz

Shock resistance

Acc. to EN 60068-2-27

30 for 18 ms

Shock resistance

Acc. to EN 60068-2-29

25 for 6 ms

EMC

Acc. to EN 6100-6-2,
EN 61000-6-3

12

Complied with

Frequency band

E-GSM 900 / GSM 1800

Power class

GSM 900:4 (2 CO) / GSM 1800:1 (1 CO)

GPRS class

Multislot Class 8, operation mode Class B, HSCSD, SAT

Connections
Terminals

screw (Pozidriv)

Conductor cross-sections of main current paths


- Rigid, max.
- Flexible, with end sleeve, min.

mm2
mm2

1.5 ... 4
1 ... 2.5

Ambient temperature

-20 ... +50

Storage temperature

-20 ... +50

Humidity at 40 C

0 ... 95

Siemens LV 10.1 2011

12/29

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
GSM alarm modules

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V DC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

GSM alarm modules


For GSM network operating with two alarm
inputs and one switching output
with backup battery for signaling in the event of
power failures
230

24

5TT7 120-0

1 unit

027

0.279

Rod aerial with magnet base, with MMC connection and connecting cable

5TT7 908-1

1 unit

027

0.075

Flat form for adhesion, with MMC connection


and connecting cable

5TT7 908-2

1 unit

027

0.048

4AC2 402

1 unit

027

0.081

Aerials1)

Electronic power supply unit


SELV, short-circuit resistant
For supplying the 5TT7 120 GSM alarm modules
within a supply voltage range of 150 to 230 V AC
For further information, please refer to chapter
Transformers, Bells and REG Socket Outlets.

12

1)

Essential accessories.

* You can order this quantity or a multiple thereof.

12/30

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Fault signaling units

Overview

Benefits

Fault signaling units are used in small plants where the installation of complex fault signaling systems would be too labor-intensive and too expensive. In the event of a fault, they enable fast
fault localization of all monitoring devices and limit monitors from
a central location. This increases plant availability. With the correct sensor configuration, they also provide the option of preventative maintenance.
4 fault signal inputs with LED
1 LED as centralized fault indicator
One unit each for centralized fault indication and acoustic
signaling
With acknowledgment for acoustic indicators
Open-/closed-circuit principle to the 4 inputs can be adjusted
via jumpers X1 - X2
A maximum of 39 5TT3 461 expansion fault signaling units can
be connected to the 5TT3 460 centralized fault signaling unit
The maximum possible cable length between 5TT3 460 centralized fault signaling units and 5TT3 461 expansion fault signaling units is approx. 100 m with a conductor cross-section
of 1.5 mm2.

Ultra compact device designs that only require the smallest of


spaces in distribution boards
The modular design means that it is easy to add devices as
your system expands.

Technical specifications
5TT3 460

5TT3 461

IEC 60255; IEC 61810

Standards
Rated control voltage Uc

V AC

230

Primary operating range

Uc

0.8 ... 1.1

Rated frequency fn

Hz

50/60

Fault signaling inputs S1 ... S4

V AC

230

Signal voltage

7 ... 10

Noise pulse duration

ms

 100

Acknowledgment pulse duration

ms

 200

Rated operational voltage Ue

V AC

230

--

Rated operational current Ie

--

Minimum contact load

V; mA

10; 100

--

To terminals S and H

Contacts

12

Connections
screw (Pozidriv)

Terminals

PZ 1

Conductor cross-sections
- Rigid, max.
- Flexible, with end sleeve, min.
Permissible ambient temperature

mm2
mm2

2 2.5
1 0.5

-20 ... +60

Acc. to IEC 60068-2-30

Humidity class

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Centralized fault signaling units with transparent cap


230

230

5TT3 460

1 unit

027

0.149

5TT3 461

1 unit

027

0.124

Expansion fault signaling units with transparent cap


230

--

--

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/31

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
EMERGENCY STOP modules

Overview

Benefits

EMERGENCY STOP circuits are common safety measures in all


laboratory equipment and industrial plants. The EMERGENCY
STOP modules used here must meet the most rigorous demands
with regard to functional reliability. Benchmark is the degree of
self-monitoring. The Directive 98/37/EC on Safety of Machines,
valid from 31.02.1994, only specifies global safety standards.
Details on how to implement individual safety demands are defined in standards, e.g. by the European Committee for Electrotechnical Standardization (CENELEC), which are based on international standards.

The electrical isolation between electric circuit and control


meets the requirements of the standard
An LED for the operating and switching state provides constant information on the operating state
The safety category 4 to EN 954-1 expands the application
options in many fields
Compliance with the regulations according to EC Machine
Directive 98/37/EC supports a high safety standard for those
working in the plants.

Technical specifications
5TT5 200
IEC 60204-1; EN 60204-1 (VDE 0113-1)

Standards
Supply
Rated control voltage Uc
- Primary operating range

V AC
Uc

230
0.8 ... 1.1

Hz

50

Rated power dissipation Pv

Coil/drive
Contact per pole

VA

3.5
0.8

Control voltage

Terminal Y1

V AC/DC

24

Control current

Terminal Y1

mA DC

45

ms

500

Electrical isolation, creepage distances and clearances, actuator/contact

mm

Rated impulse withstand voltage Uimp actuator/contact

kV

>4

A
A
A

3
2
5

mm

>1

Switching
cycles

105

Switching
cycles/h

600

Rated frequency fn

Recovery time
Safety

Contacts
Contacts

NO contacts
NC contacts
NO contact/NC contact

AC-15
AC-15
AC-1

Contact gap
Electrical service life

12

AC-15, 2 A, 230 V AC

Reliable switching frequency


Vibration resistance
Amplitude

Acc. to EN 60068-2-610

Up to 55 Hz mm

0.35

Connections
Terminals

screw (Pozidriv)

PZ 1

Conductor cross-sections of main current paths


- Rigid
Max.
- Flexible, with end sleeve
Min.

mm2
mm2

2 2.5
1 0.5

Permissible ambient temperature

0 ... +50

Acc. to EN 60068-1

Resistance to climate

0/55/04

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

230

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

EMERGENCY STOP modules


400

5TT5 200

1 unit

027

0.284

* You can order this quantity or a multiple thereof.

12/32

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Level relays

Overview

Benefits

Level relays are used for the monitoring and control of conductive, non-combustible liquids and powders. They ensure overflow and dry run protection. Due to their sensor performance, the
devices can also be used for general resistance monitoring.
LED displays:
Green LED: lights up when operational voltage is applied
Yellow LED: lights up if MIN output relay is activated
Red LED: lights up if MAX output relay is activated.

The measuring range up to 450 k enables a differentiation between foam and liquid. It also increases the universal application
for resistance measurements.
Due to its low-frequency, electrically isolated measuring circuit,
the device has a high immunity to interference against system
coupling, which enables cable lengths of up to 1500 m and suppresses the effects of electrolysis in the liquid
The two outputs for minimum and maximum control can also
be used for the advance warning and tripping of limit values
3 electrode connections for 1-step and 2-step level control
All standard products can be used as electrodes
High immunity to interference of the measuring circuit isolated
from the system
Programmable for open-circuit principle (with bridge X2 COM)
or closed-circuit principle (without jumper)
Separately adjustable delay times for tv min and tv max,
0.2 s to 2 s.

Technical specifications
5TT3 435
IEC 60255; IEC 61810

Standards
Supply
Rated control voltage Uc
- Primary operating range

V AC
Uc

230
0.8 ... 1.1

Rated frequency fn

Hz

50/60

Setting range of the liquid level

k

2 ... 450

%
%

3
6

Switching point hysteresis of set value


At 450 k
At 2 k
Voltage temperature influence

From set value

<2

Max. cable length to the


Electrodes at 100 F/km

Set value k
450
100
35
10
5

m
m
m
m
m

50
200
500
1500
3000

Electrode voltage

Max.

V AC

Approx. 10

Electrode current

Max.

mA AC

Approx. 1.5

Response delay

Adjustable

0.2 ... 20

OFF-delay

Adjustable

0.2 ... 20

Rated operational voltage Ue

250

Rated operational current Ie

kV
kV
kV

4
4
4

12

Test voltage
Input/auxiliary circuit
Input/output circuit
Auxiliary/output circuit
Connections
Terminals

screw (Pozidriv)

Conductor cross-sections
- Rigid
- Flexible, with end sleeve

Max.
Min.

Permissible ambient temperature


Resistance to climate

Acc. to EN 60068-1

PZ 2
mm2
mm2

2 2.5
1 0.5

-20 ... +60


20/60/4

Siemens LV 10.1 2011

12/33

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Level relays

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

230

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Level relays
230

5TT3 435

1 unit

027

0.188

5TG8 223

1 1/24 units

027

0.087

Immersion electrodes
Made of stainless steel, with PG13 sealing cap
Temperature range 0 ... 60 C
Suitable for pure water in open containers
With terminal connection

12

* You can order this quantity or a multiple thereof.

12/34

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Line circuit relays

Overview

Benefits

Line circuit relays are used to interrupt circuits and prevent electromagnetic fields in circuits where there are currently no active
loads.
If the loads are disconnected, and the line circuit relay measures
a usage of only 2 to 20 VA - adjustable - it disconnects the cable
to the supply voltage and switches over to extra-low voltage. As
soon as loads are reconnected, the line circuit relay detects the
increase in usage and switches back to the supply voltage.
While the line circuit relay switches off any unnecessary system
components, it is not a device for ensuring isolation in the sense
of safe disconnection.

High availability to a wide range of loads, as all resistive,


capacitive and inductive loads are detected
Adjustable from 2 VA to 20 VA
With status display for contact adjustment
With switch continuously ON
With safety information on stickers for socket outlets and
distribution boards.

The line circuit relay is unable to detect consumers with electronic power supply units, e.g. electronically controlled vacuum
cleaners. It is expedient to connect such equipment to a base
load resistor (PTC resistor) so that the line circuit relay is reset to
supply voltage.

Technical specifications
5TT3 171
IEC 60255; IEC 61810

Standards
Rated control voltage Uc

V AC

230

Primary operating range

Uc

0.85 ... 1.15

Rated frequency

Hz

50/60

VA
VA

5
2.6

VA

2 ... 20

Electronics
Contacts

Rated power dissipation Pv


Monitoring voltage
Response value

adjustable

Release value

% of the response value

Rated impulse withstand voltage Uimp

Input/output

70
kV

>4

V AC

250

AC-1
AC-11

A
A

16
3

Electrical service life

In switching cycles at 3 A

AC-11

Terminals

screw (Pozidriv)

Rated operational voltage Ue


Rated operational current Ie

 contact

Contacts

5 105

12

PZ 1

Conductor cross-sections
Rigid
Flexible, with end sleeve

Max.
Min.

Permissible ambient temperature

mm2
mm2

2 2.5
1 0.5

-20 ... +45

Degree of protection

Acc. to IEC/EN 60529

IP20, with connected conductors

Safety class

Acc. to EN 61140/VDE 0140-1

II

Humidity class

Acc. to IEC 60068-2-30

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Line circuit relays


For disconnecting the voltage or field circuit of
electrical systems even when loads are disabled.
1 NC

250

16

230

5TT3 171

1 unit

027

0.087

5TG8 222

1 unit

027

0.006

Base load resistors for electronic devices


With 15-cm connection wires, end sleeves
and shrink sleeving

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/35

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Dusk switches

Overview

Benefits

Dusk switches are used for the demand-oriented switching of


lighting installations for shop windows or paths in order to cut
operating costs.
A light sensor measures the level of daylight. Switching depends
on the desired brightness. A time delay and the switching
hysteresis prevent clock-pulse behavior.
The sensor must be mounted so that it is not influenced by the
lighting feedback.

The devices 7LQ2 101 and 7LQ2 103 have 2 switching channels that can be set independently of each other. This requires
a light sensor
12 dusk switches can be switched parallel to a light sensor.
This saves the multiple installation of light sensors in a single
system and all dusk switches operate independently of each
other and can be adjusted individually.

Technical specifications
7LQ2 100

7LQ2 102

7LQ2 103

5TT3 303

V AC

230

Uc

0.8 ... 1.2

Rated frequency fn

Hz

45 ... 65

Measuring ranges, setting ranges

Lux

2 ... 500

2 2 ... 500

2 ... 500

2 2 ... 500

2 ... 500

75 25
No

No
2 50 ... 100
25

75 25
No

No
2 50 ... 100
25

50
No

Rated control voltage Uc


Primary operating range

At 50/60 Hz

Time delay

Non-adjustable
Adjustable

Status indication, LED

Switching status indication


Switching state OFF
Switching state ON

Different phases

Instantaneous
Green
Red
W

Incandescent lamp load


Actuator/contact permissible
Contact/contact

No
No
No

2000

2 2000

2000

2 2000

1200

Yes
No

Yes

No

Yes

No
No

Creepage distances and


clearances
Actuator/contact
Contact/contact

mm
mm

4
No

No

No
No

Rated impulse withstand voltage Uimp


1.2/50 s

Actuator/contact
Contact/contact

kV
kV

> 2.5
No

> 2.5

No

> 2.5

No
No

Contacts

 contact

1 NO

2 NO

1 NO

2 NO

1 NO

Electrical isolation

12

7LQ2 101

EN 60730

Standards

Rated operational voltage Ue

V AC

250

Rated operational current Is


- At p.f. = 1
- At p.f. = 0.4

A
A

16
4

V; mA

10; 100

Minimum contact load


Contact switching

Closes with approaching


darkness

Terminals 3/4

10
2
5/6 and 9/10

3/4

5/6 and 9/10

No

Connections
Terminals

screw (Pozidriv)

Conductor cross-sections
- Rigid
- Flexible, with end sleeve

Min.

PZ 1
mm2
mm2

1.5 ... 6
0.75

1.5
0.5

Permissible ambient temperature


- Device
- Light sensor

C
C

-10 ... +55


-30 ... +70

--

Permissible humidity
- Device
- Light sensor

%
%

< 80
< 98

--

IP20, with connected conductors


IP55
IP65

IP54
No

Environmental conditions

Degree of protection
- Device
- Light sensor

Acc. to EN 60529

Safety class

Acc. to EN 61010

12/36

Siemens LV 10.1 2011

II

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Dusk switches

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.

V AC

A AC

V AC

MW

Setting range 2 ... 500 lux


with 7LQ2 910 light sensor
for surface mounting, IP55
250
16

230

7LQ2 100

1 unit

027

0.287

With 7LQ2 911 light sensor,


for flush wall mounting, IP65
250
16

230

7LQ2 102

1 unit

027

0.332

Setting range 2 ... 500 lux


with 7LQ2 910 light sensor,
for surface mounting, IP55,
expandable to 24 channels through parallel
switching of 12 devices, which can be mutually
controlled through a light sensor.
250
16
230
3

7LQ2 101

1 unit

027

0.253

with 7LQ2 911 light sensor,


for flush wall mounting, IP65
expandable to 24 channels through parallel
switching of 12 devices, which can be mutually
controlled through a light sensor.
250
16
230
3

7LQ2 103

1 unit

027

0.279

5TT3 303

1 unit

027

0.226

kg

Dusk switches
1-channel version,

2-channel version,

1-channel version,
Setting range 2 ... 500 lux
for surface mounting, IP54,
with integrated light sensor
250
10

230

12

Replacement light sensors


With watertight, resistant resin molding material,
heat-resistant to 70 C
Degree of protection IP55, for 7LQ2 100 and 7LQ2 101, B
for surface mounting, 2 ... 500 lux

7LQ2 910

1 unit

027

0.038

Degree of protection IP65, for 7LQ2 102 and 7LQ2 103, B


for flush wall mounting, 2 ... 500 lux

7LQ2 911

1 unit

027

0.080

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/37

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Temperature controllers

Overview

Benefits

The temperature controllers are used for controlling or limiting


temperatures in residential and non-residential buildings, as well
as in industrial areas. They're used for heating registers, panel
and hot air heating and direct floor heating, as a limiting thermostat for air-conditioning systems and cooling systems, switchgear cabinet cooling, etc. as well as for temperature control in
humid and dusty rooms. Can also be used for inaccessible room
temperature setting for rooms in public buildings, such as
schools, dayrooms and comparable applications.

Electronic temperature controllers with red/green LED for supply voltage indication, switching status indication and temperature sensor monitoring. This supports the monitoring of safe
operation at all times
The temperature sensor with the measuring element KTY or a
PT100 is monitored for short-circuits and interruptions. This
protects against unpleasant surprises during operation.

Technical specifications
7LQ2 001

7LQ2 002

7LQ2 003

7LQ2 005

0 ... +60

+40 ... +100

2 ... +400

EN 60730

Standards
V AC

230

Uc

0.8 ... 1.2

Rated frequency fn

Hz

45 ... 65

Measuring ranges, setting ranges

-30 ... +30

1 ... 5

Rated control voltage Uc


Primary operating range

Switching hysteresis

At 50/60 Hz

Adjustable

4 ... 20

Status indication, LED


Switching status indication
Actuating voltage

Green

Switching state ON

Red
Red flashing

Break or short circuit of the sensor conductor

12

Different phases

Actuator/contact permissible

Electrical isolation

Creepage distances and


clearances, actuator/contact

Yes
mm

Rated impulse withstand voltage Uimp


(1.2/50 s)

Actuator/contact

kV

> 2.5

Contacts

 contact

1 CO

Rated operational voltage Ue

V AC

250

Rated operational current Is


- At p.f. = 1
- At p.f. = 0.4

A
A

16
4

V; mA

10; 100

Terminals

3/4

Minimum contact load


Contact switching

Closes with increasing


temperature

Connections
Terminals

screw (Pozidriv)

Conductor cross-sections
- Rigid
- Flexible, with end sleeve

Min.

PZ 1
mm2
mm2

1.5 ... 6
0.75

Permissible ambient temperature


- Device
- Temperature sensor

C
C

-10 ... +55


-30 ... +105

--

Permissible humidity
- Device
- Temperature sensor

%
%

 80
 98

--

IP20, with connected conductors


IP65

--

Environmental conditions

Degree of protection
- Device
- Temperature sensor

Acc. to EN 60529

Safety class

Acc. to EN 61010

12/38

Siemens LV 10.1 2011

II

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Temperature controllers

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Temperature controllers
With KTY 11-6 temperature sensor
Adjustment range -30 ... +30 C, 1 CO
250

16

230

7LQ2 001

1 unit

027

0.259

230

7LQ2 002

1 unit

027

0.260

7LQ2 003

1 unit

027

0.260

7LQ2 005

1 unit

027

0.232

7LQ2 900

1 unit

027

0.032

Adjustment range 0 ... +60 C, 1 CO


250

16

Adjustment range +40 ... +100 C, 1 CO


250

16

230

Temperature controllers without temperature


sensor
For PT100 measuring element
(not included in delivery)
Adjustment range +2 ... +400 C, 1 CO
250

16

230

KTY 11-6 replacement temperature sensors


Safety class IP65, for 7LQ2 001, 7LQ2 002 and
7LQ2 003, encapsulated,
with watertight/resistant resin material,
with 1 m silicone line,
heat-resistant up to 105C,
can be extended up to 100 m
230

12

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/39

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
P.f. controllers

Overview
The p.f. controllers monitor the phase displacement between
current and voltage. Because the phase displacement angle
changes with the load of the motor, this measurement method is
ideal for the monitoring of asynchronous motors for underload
and no-load operation, independent of size. However, in some
cases, the p.f. barely changes if the load of the motor changes,
e.g. in the case of relatively minor load changes on large-scale
motors or single-phase split-pole motors or collector motors.

in the event of valve closure or dry runs. A current transformer is


used for higher rated currents.

The p.f. controller monitors single and three-phase asynchronous motors up to approx. 5 A (without current transformer) for
underload and no-load operation. This is phase-sequence-independent and increases plant availability. Typical applications are
fan monitoring in the case of V-belt breakage, pump monitoring

If the p.f. value set at the p.f. monitor is fallen below for the duration of the set response delay, the output relay switches to the
alarm state and the red LED lights up. If it exceeds the p.f. value,
the output relay switches back without any significant delay.
Adjustable p.f. response value, from 0 to 0.97
Current range up to 8 A
LED display for operation and alarm
Automatic resetting of alarm.

Benefits
The ultra compact p.f. controller requires only the smallest of
spaces and saves costs.

Technical specifications
5TT3 472
IEC/EN 60255, VDE 0435

Standards
3 V AC

400

Uc

0.8 ... 1.1

Frequency range fn

Hz

45 ... 65

Rated power dissipation Pv

VA

Approx. 11

kV

<4

Rated control voltage Uc


With AC supply

Primary operating range

Against contacts

Rated impulse withstand voltage Uimp

For AC systems

Current measuring circuits


Current measuring range Imeas
For 2 s
For 0.5 s

Short-time load carrying capacity

12

A AC

0.4 ... 8

A
A

20
40

Current transformer, Class 3 or better

Secondary current

1 or 5

Setting range

Adjustable

p.f.

0 ... 0.97

Response delay

Adjustable

1 ... 100

Short-circuit strength

Fuse 4 A gL

Contacts

 contact

1 CO

Rated operational voltage Ue


Rated operational current Ie

Thermal current
AC-15 NO contacts
AC-15 NC contacts
AC-13 at 24 V DC

Minimum contact load

V AC

250

A
A
A
A

4
3
1
1

V; mA

10; 100

Connections
Terminals

screw (Pozidriv)

Conductor cross-sections
- Rigid
- Flexible, with end sleeve

Max.
Min.

PZ 2

Permissible ambient temperature

mm2
mm2

2 2.5
1 0.5

-20 ... +60

Resistance to climate

Acc. to EN 60068-1

20/60/4

Degree of protection

Acc. to EN 60529

IP20, with connected conductors

Selection and ordering data


Contacts

Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

P.f. controllers
For monitoring of the underload of motors
up to approx. 5 A AC
by making p.f. measurements,
setting range p.f. from 0 to 0.97
1 CO

3 400

0.4 ... 8

5TT3 472

1 unit

027

0.081

* You can order this quantity or a multiple thereof.

12/40

Siemens LV 10.1 2011

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Thermistor motor protection relays

Overview
Thermistor motor protection relays monitor the thermistors
wound in motors. This helps prevent thermal motor overloads,
e.g. due to high switching frequency, single-phasing, disabled
cooling or excessive ambient temperatures. Up to 6 thermistors
in series can be monitored. A conductor break in the sensor conductor will immediately trip the device. The device can also be
used for monitoring wound quick-break switches - e.g. bimetal
thermostats. This offers all-round motor protection.
For the detection of
- Temperature limits being exceeded
- Wire breaks in sensor circuits
1 input for 1 to 6 thermistors
With 2 LEDs green/red for ready-to-run and fault

Response value: 3.2 to 3.8 k


Release value: 1.5 to 1.8 k
Max. cable length of sensor supply cable NYM 2 1.5 mm2
is 100 m
Remote Reset: over A1/A2 (NC contact) or over X1/X2
(NO contact)
LED displays:
Green LED: lights up when operational voltage is applied
Red LED: lights up in the event of overtemperatures or an
interruption in the sensor circuit.

Benefits
The test button for the diagnosis of the devices ensures high
functional reliability for users
The ultra compact thermistor motor protection relay requires
only the smallest of spaces. This saves costs

A remote reset enables the device to be switched back on


again centrally at any time. This increases plant availability.

Technical specifications
5TT3 431
5TT3 432
IEC 60255; IEC 61810

Standards
Rated control voltage Uc

V AC

230

Primary operating range

Uc

0.9 ... 1.1

Rated frequency

Hz

50/60

Response value

k

3.2 ... 3.8

Release value

k

1.5 ... 1.8

Minimum contact load

V; mA

10; 100

Rated insulation voltage Ui

Between coil/contact

kV

Rated impulse withstand voltage Uimp

Actuator/contact

kV

> 2.5

Contacts

 contact (AC-11)

Rated operational voltage Ue

V AC

230

Rated operational current Ie

A
mm

5
4

Actuator/contact

12

Connections
Terminals

screw (Pozidriv)

Conductor cross-sections
- Rigid
- Flexible, with end sleeve

Max.
Min.

PZ 1

Permissible ambient temperature

mm2
mm2

2 2.5
1 0.5

-20 ... +60

Acc. to EN 60068-1

Resistance to climate

20/60/4

Selection and ordering data


Ue

Ie

Uc

Mount- DT
ing
width

V AC

A AC

V AC

MW

Order No.

Price
PU
per PU (UNIT,
SET,
M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Thermistor motor protection relays


230

230

5TT3 431

1 unit

027

0.167

230

5TT3 432

1 unit

027

0.172

With fault storage,


reset pushbutton and remote reset
230

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

12/41

Siemens AG 2011

Monitoring Devices
Monitoring Devices for Plants and Devices
Notes

12

12/42

Siemens LV 10.1 2011

13

Siemens AG 2011

Software
13/2

Introduction

13/4
13/5
13/6

Planning the Power Distribution


System with SIMARIS
SIMARIS design
SIMARIS project
SIMARIS curves

13/7

13/9
13/11
13/13
13/14
13/15

13/16
13/19

ALPHA SELECT Planning and Configuration Software


Configuring, Visualizing and
Controlling with SIMATIC
SIMATIC PCS 7 powerrate
SIMATIC WinCC powerrate
SIMATIC PCS 7 Library PAC3200
3WL/3VL block library
for SIMATIC PCS 7
PAC3200 block library
for SIMATIC WinCC
PAC4200 block library
for SIMATIC WinCC
Configuring, Visualizing and
Controlling with SENTRON
SENTRON powermanager
Switch ES Power

Technical Information
can be found at
www.siemens.com/lowvoltage/support
under Product List:
- Technical Specifications
under Entry List:
- Updates
- Download
- FAQ
- Manuals
- Characteristics
- Certificates

13

and at
www.siemens.com/lowvoltage/configurators
- Configurators

Siemens LV 10.1 2011

Siemens AG 2011

Software
Introduction

Overview
SIMARIS design
Software tool for the quick and effective dimensioning of power
distribution for non-residential and industrial buildings:
Dimensioning on the basis of real products according to
acknowledged technical rules and standards (VDE, IEC)
Automatic access to an integrated product database
Easy implementation and modification in the planning and
realization concept
Reduction of routine work

SIMARIS project
Software tool to provide a quick overview of the space requirement for electrical power distribution and simple costing for purpose-built and industrial buildings:
Automatic selection and placement of matching distribution
systems
Fast overview of space requirements and budget
Thorough planning from the medium voltage supply to the
distribution board
Easy adaptation of the project plans in case of changes in
use or expansions
New from Version 2.0 upwards: Automatic generation of
specifications
SIMARIS curves
Software tool for quickly and easily comparing tripping characteristics in Siemens low-voltage-protection equipment:
Characteristic curve display and overview
Device selection via order number or selection aid
Saving of selected devices as favorites
Saving of several characteristic curves including selected
settings as a complete project

13
More information about SIMARIS
You can find more information and order options on the Internet
at:
www.siemens.com/simaris

13/2

Siemens LV 10.1 2011

Siemens AG 2011

Software
Introduction

SIMATIC PCS 7 powerrate, SIMATIC WinCC powerrate


SIMATIC PCS 7 and WinCC powerrate are add-ons to PCS 7
and WinCC respectively and throw light on power consumption
from the infeed to the load.
Identification of power-intensive consumer devices and processes in order to introduce measures for improving power
efficiency
Comparison of consumption profiles for greater efficiency of
process design
Optimizing the company according to energy parameters
based on an assessment of consumption and costs
Complying with the contractually agreed power limit, thus
preventing higher power supply costs or penalty payments.
SIMATIC PCS PAC3200 7 Library, SENTRON PAC3200 block
library for SIMATIC WinCC
The SENTRON PAC3200 block library enables the seamless integration of the SENTRON PAC3200 multifunction measuring instrument in the PSC 7 or WinCC process world.

3WL/3VL block library for SIMATIC PCS 7


The 3WL/3VL block library enables the seamless integration of
the 3WL/3VL circuit breaker in the PSC 7 process world.

13
Switch ES Power
Shared software platform for communication-capable
SENTRON 3WL and SENTRON 3VL circuit breakers:
Parameterization, documentation, operation and monitoring
in one software
Clear representation of all available parameters
All the available status information and measured values are
displayed in dialog boxes
Software for SENTRON 3WL and SENTRON 3VL

Siemens LV 10.1 2011

13/3

Siemens AG 2011

Software
Planning the Power Distribution System with SIMARIS
SIMARIS design

Overview

Benefits

SIMARIS design

Reduction of routine work


Dimensioning on the basis of real products according to
acknowledged technical rules and standards
Integrated product database
Detailed knowledge of products and systems not required
Easy implementation and modification in the planning and
realization concept
Clear-cut presentation of changes with specification of the
revision date
Detailed parts lists with exact product descriptions
Easy adaptation in case of changes in use or expansions
Comprehensive documentation with simple data transfer
(Office, CAD etc.)

Application

SIMARIS design is a software tool for the quick and effective dimensioning of power distribution for non-residential and industrial buildings.
In the planning phase already, the complete circuit can be dimensioned on the basis of real products. This avoids additional
costs due to uncoordinated systems in the implementation
phase. The right components and distribution systems for the
case in question are selected automatically in the light of the
product data stored in SIMARIS design.
Every configuration of the electric power distribution is subject
to frequent change and adaptation in the implementation phase
as well as in the planning phase. SIMARIS design incorporates
each change into the supply concept and automatically checks
its reliability in terms of the regulations and standards currently
in force.

13

Even an analysis of selectivity, for example for safety power supply elements, can be simply performed with SIMARIS design. All
these steps are precisely documented in SIMARIS design.
More information and order options
can be found on the Internet at:
www.siemens.com/simarisdesign

13/4

Siemens LV 10.1 2011

SIMARIS design is suitable for dimensioning electric power distribution systems in all industrial and non-residential buildings.
From shopping centers to hospitals and production buildings
with SIMARIS design it is possible to reduce the amount of work
required for the overall planning of power distribution systems
and hence the time spent on selecting and dimensioning the
necessary equipment.

Siemens AG 2011

Software
Planning the Power Distribution System with SIMARIS
SIMARIS project

Overview
Detailed information about Siemens units or their order numbers
are not needed because SIMARIS project makes the selection
automatically on the basis of the parameters entered. For each
item of switchgear or each distribution, SIMARIS project takes
the wiring, control and measurement etc. into account.
A system plan drawn up professionally in SIMARIS design can
also be imported into SIMARIS project, which means that selecting devices becomes redundant and the project structure is
formed automatically. Convenient output variants are available
to document the results, and Version 2.0 and higher also includes the automatic generation of specifications for the
planned systems.
Typical versions of a system planned in SIMARIS project can be
saved and imported continually into new projects from the favorites library. Automatically created systems can also be subsequently optimized or changed. This is particularly relevant if
planning becomes more detailed and the budget needs to be reinforced as a result.

SIMARIS project is a software tool for providing a quick overview


of the space requirement for electrical power distribution in nonresidential and residential buildings, for simple costing of the required systems and for the automatic generation of specifications.

For detailed calculation of costs on an up-to-date and regional


basis and for more project support please contact your
Siemens representative.
More information and order options
can be found on the Internet at:
www.siemens.com/simarisproject

The following is determined in SIMARIS project based on the


pre-defined project structure and the basic technical specifications selected:
For medium-voltage switchgear: selection of the required system and the required fields, then presentation of a front view
with dimensions.
For transformers: selection of the required system and then
the required quantity. Selected transformers are presented as
a parts list.
For low-voltage switchgear and distribution boards: selection
of the required protection devices and switching devices per
system. The best suited distribution system is automatically
selected from the created list of distribution devices, is
equipped with the devices and presented graphically in an
automatically generated front view including dimensions.
For busway systems: selection of the required system, then
specification of the length and selection of the additionally required components, e.g. infeeds, junction units and tap-off
units. All the resulting components are listed in a parts list.

Benefits
Automatic selection and placement of matching distribution
systems
Fast overview of space requirements and budget
Thorough planning from the medium voltage supply to the distribution board
Intuitive and easy to operate
Saving planned systems for similar projects individually in the
favorites library and importing them from there into new projects
e.g. graphic views, lists and specifications
Easy adaptability to changes in use or expansions
Importing of a project drawn up in SIMARIS design 5.0 professional

13

Application
SIMARIS project is suitable for establishing space requirements
and determining the costs of electrical power distribution in all
industrial and non-residential buildings. From shopping centers
to hospitals and production buildings with SIMARIS project it is
possible to reduce the amount of work required for the overall
planning of power distribution systems and hence the time spent
on selecting and dimensioning the necessary equipment.

Siemens LV 10.1 2011

13/5

Siemens AG 2011

Software
Planning the Power Distribution System with SIMARIS
SIMARIS curves

Overview

Benefits

Characteristic curve display and overview


Clearly structured catalog selection
Device selection via order number or selection aid
Saving of selected devices as favorites
Saving of several characteristic curves including settings as
complete project
User-friendly system documentation

Application
SIMARIS curves is a software tool for displaying tripping characteristics, let-through power curves and let-through current
curves of Siemens low-voltage controls and fuses. Ranging from
shopping malls through hospitals to production shops
SIMARIS curves lets you call up the required curves quickly and
documents in the required output language.

SIMARIS curves is a software tool for the quick and simply comparison of tripping characteristics for Siemens low-voltage-protection equipment and fuses.
With SIMARIS curves it is possible to simulate parameter settings on protective devices. The respective characteristic curve
is selected by direct entry of the Siemens order number or with
a user-friendly selection tool. Individual products with default attributes can be stored as favorites and called up again. Tripping
characteristics with tolerance ranges are available for presentation along with let-through current and let-through power characteristic curves. A printout summary documents the characteristic
curves selected and each of their settings.
More information and order options
can be found on the Internet at:
www.siemens.com/simariscurves

13

13/6

Siemens LV 10.1 2011

Siemens AG 2011

Software
ALPHA SELECT Planning and
Configuration Software

Overview
Whether you are an installation engineer or a control cabinet engineer, an electrical wholesaler or a planner the software
ALPHA SELECT makes it quicker and easier than ever before to
plan and configure distribution boards and meter cabinets.
Easy-to-use, intuitive functions accompany you step-by-step
through the entire project, from planning to installation. Configuration errors are virtually impossible thanks to the collision tests
and configuration rules saved in the program.
ALPHA SELECT comprises:
ALPHA SIMBOX small distribution boards
ALPHA 400-ZS meter cabinets
ALPHA Distribution Boards
ALPHA 8HP molded-plastic distribution systems
ALPHA BOX IEC wall-mounted distribution boards
In addition you can use the electronic catalogs (EGH selection
catalog and CA 01) to select BETA low-voltage circuit protection
products, GAMMA instabus products (for building management) and many other items from the Siemens Industry product
selection.
Calculation of power loss

13
Selection of the ALPHA distribution system

Parts list with calculation

Distribution board equipment, front view

Illustration of the device structure as single-pole circuit diagram

Siemens LV 10.1 2011

13/7

Siemens AG 2011

Software
ALPHA SELECT Planning and
Configuration Software
Start with the selection of a suitable distribution system and distribution board by selecting the required degree of protection,
safety class and dimensions. You can then just drag & drop the
required assembly kits, devices and accessories of your choice.
Essential accessories are determined automatically. When selecting the devices, customer specifications can be prepared
using either item numbers or in accordance with the electrical
structure. In case 2 a graphical representation in the form of a
1-pole circuit diagram has been available since the launch of
Version 6.0.
The graphic representation of the structure enables individual
levels, such as doors, covers, equipment racks or devices, to be
visualized, rendered transparent and hidden in order to provide
users with a constant overview of already configured components.
There is also an integrated option for power loss calculation
which enables comparison of the calculated power loss values
of the devices installed in the distribution board with the thermal
rating of the distribution board, giving due consideration to the
point of installation and the permissible overtemperature
(related to 35 C ambient temperature).
Frequently required components can be saved as favorites for
integration in other projects at any time.
Used in conjunction with existing calculation aids, users are able
to tailor parts lists, assembly drawings and assembly structures
to individual requirements and output as both a hard copy and
in electronic form.
In addition to planning and calculation in the program, users are
also able to produce parts lists and graphic documentation to
accompany customer quotations or for ordering the required
components.
The workshop version, which comprises a structured list of the
distribution boards and the respectively installed parts and
graphical representation of the different user-defined layers, directly supports the building of distribution boards configured using ALPHA SELECT.
www.siemens.com/alpha-select

13

Benefits
Cabinet selection: simple selection of cabinet system, degree
of protection, safety class and dimensions
Selection of equipment using technical specifications
Alternative structuring of the devices according to
- Electrical structure and graphic output as 1-pole circuit diagram
- Item numbers in the customer specifications
Positioning of assembly kits and devices using drag & drop
Automatic determination of key accessories
Numbering of assembly kits in the assembly drawing
Automatic issue of item codes for devices
Calculation of power loss
Differentiated calculation options, including allowance made
for assembly work
Listing in the assembly structure of devices placed in the assembly kits, including numbering of the assembly kits and the
item codes of the devices
Easy drawing up of quotations for projects: Clearly arranged
output selection for parts lists, assembly drawing and assembly structure
Clearly arranged calculation aids. Calculations for individual
items and assembly, for material surcharges, shipment costs,
discounts and miscellaneous extras are easy to perform in the
parts list. Standard discounts for each price group can also be
saved in the memory.
Option for quotations with individual company logo
Update over the web with quick download times
Manual available as a download

Technical specifications
ALPHA SELECT system requirements:
Processor: from 1 GHz
Main memory: minimum 512 MB
operating system: Windows 7/VISTA/XP/2000
Free hard disk space: 100 ... 500 MB
(depending on the number of modules installed)
Display resolution: minimum 1024768 with 16-bit color intensity

More information
Support for planning and configuration is available from:
www.siemens.com/lowvoltage/technical-support
Tel.:+49 (0)9 11 8 95 72 22

13/8

Siemens LV 10.1 2011

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
SIMATIC PCS 7 powerrate

Overview

Benefits
Identification of power-intensive consumer devices and processes in order to introduce measures for improving power efficiency
Comparison of consumption profiles for greater efficiency of
process design
Optimizing the company according to energy parameters
based on an assessment of consumption and costs
Complying with the contractually agreed power limit, thus preventing higher power supply costs or penalty payments
Integration of the SENTRON PAC3200 and
SENTRON PAC4200 measuring devices, with a quick overview of selected measured values and signals
Integration of switches, with an overview of switch status and
switching possibilities
Exact assignment and comparison of the consumption data of
certain work processes through batch-related consumption
recording

SIMATIC PCS 7 is an add-on to PCS 7 which throws light on


power consumption from the infeed to the load. Power data are
continuously collected, archived and processed further. With an
exact knowledge of the consumption profile, it is possible to
identify savings potential, optimize your power supply conditions and hence, lower your power costs. Monitoring the contractually agreed power limit helps on the one hand to prevent
unnecessarily high power prices or penalties and on the other
hand to make full use of the fixed power limit.

Application
SIMATIC PCS 7 powerrate is used in all areas in which PCS 7 is
used and energy efficiency considerations play a major role. Full
integration in PCS 7 means that there is no need for a special
system environment. Predefined modules and symbols give you
the assurance of building on tested and certified product components, with interfaces which enable customized expandability.

Batch-related consumption recording enables the exact recording and evaluation of power consumption per batch.
The integration of switches through digital inputs/outputs enables the monitoring or indication of switch status and, with suitable authorization, remote switching. With integration through
DPV1, selected measured values and signals of the
SENTRON PAC3200 and SENTRON PAC4200 multifunction
measuring instruments can be indicated online.
Data recorded and archived by SIMATIC PCS 7 powerrate can
be exported to Excel, and they can also be presented in different
reports.
Support for the WinCC Web Navigator means that the
SIMATIC powerrate functionality is also available over the web.

13

Full integration in PCS 7 enables the easy use of standard interfaces or standard functionalities from PCS 7.
Components
SIMATIC PCS 7 powerrate is made up of the following components:
Blocks for the acquisition and processing of power data
Faceplates for the presentation and processing of power data
Components for implementing load management (calculating
trends, monitoring limits, enabling/disabling loads)
Blocks for batch-related consumption recording
Blocks for the integration of measuring devices and switches
Other components, for example, for time synchronization,
data buffering or data exchange with archives
Faceplates for presenting results and for entering values (e.g.
for configuration or from manual measured values)
Excel-based reports for allocating power data to cost centers,
for batch-related evaluation and for determining and presenting the duration curve
Exporting data to Excel

Siemens LV 10.1 2011

13/9

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
SIMATIC PCS 7 powerrate

Selection and ordering data


SIMATIC PCS 7 V 6.1 SP3, V 7.0 SP3, V 7.1 and V7.1 SP1
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

SIMATIC PCS 7 powerrate V 3.0


Trial license

3ZS2 785-1CC30-0YG7

1 unit

276

0.200

3ZS2 785-1CC30-0YG0

1 unit

276

0.200

3ZS2 785-1CC30-0YE0

1 unit

276

0.200

Limited 30 day Engineering-/Runtime license

Unlimited Engineering-und AS-Runtime license1)


Also includes PAC3200 3VL/3WL block library
for SIMATIC PCS 7

Upgrade from SIMATIC PCS 7 powerrate V 2.0 to V 3.0


Unlimited Engineering-und AS-Runtime license1)
Also includes PAC3200 3VL/3WL block library
for SIMATIC PCS 7

1)

For operation on one PCS 7 OS (single workstation system or server) and


an automation system (AS). A license is required per PCS 7 OS single
workstation system or server if using additional PCS 7 OS single workstation systems or servers.

More information
Information about using SIMATIC PCS 7 Powerrate
is available from
Siemens AG, Technical Support
Tel.: +49 (0) 911 895 7 222
Fax.: +49 (0) 911 895 7 223
www.siemens.com/automation/support-request
You can find further general information on the Internet at:
www.siemens.com/powermanagementsystem

13

* You can order this quantity or a multiple thereof.

13/10

Siemens LV 10.1 2011

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
SIMATIC WinCC powerrate

Overview

Benefits
Identification of power-intensive consumer devices and processes in order to introduce measures for improving power efficiency
Comparison of consumption profiles for greater efficiency of
process design
Optimizing the company according to energy parameters
based on an assessment of consumption and costs
Complying with the contractually agreed power limit, thus preventing higher power supply costs or penalty payments
Integration of the SENTRON PAC3200 and SENTRON 4200
measuring devices, with a quick overview of selected measured values and signals
Integration of switches, with an overview of switch status and
switching possibilities
Exact assignment and comparison of the consumption data of
certain work processes through batch-related consumption
recording

SIMATIC WinCC powerrate is an add-on to WinCC which throws


light on power consumption from the infeed to the load. Power
data are continuously collected, archived and processed further.
With an exact knowledge of the consumption profile, it is possible to identify savings potential, optimize your power supply
conditions and hence, lower your power costs. Monitoring the
contractually agreed power limit helps on the one hand to prevent unnecessarily high power prices or penalties and on the
other hand to make full use of the fixed power limit.
Batch-related consumption recording enables the exact recording and evaluation of power consumption per batch.

Application
SIMATIC WinCC powerrate is used in all areas in which WinCC
is used and energy efficiency considerations play a major role.
Full integration in WinCC means that there is no need for a special system environment. Predefined modules and symbols give
you the assurance of building on tested product components,
with interfaces which enable customized expandability.
SIMATIC WinCC powerrate V 3.0 can be used with
SIMATIC S7-317 and higher.

The integration of switches through digital inputs/outputs enables the monitoring or indication of switch status and, with suitable authorization, remote switching. With integration through
DPV1, selected measured values and signals of the
SENTRON PAC3200 and SENTRON PAC4200 multifunction
measuring instruments can be indicated online.
Data recorded and archived by SIMATIC WinCC powerrate can
be exported to Excel, and they can also be presented in different
reports.
Full integration in WinCC enables the easy use of standard interfaces or standard functionalities from WinCC.

13

Components
SIMATIC WinCC powerrate is made up of the following components:
Blocks for the acquisition and processing of power data
Faceplates for the presentation and processing of power data
Components for implementing load management (calculating
trends, monitoring limits, enabling/disabling loads)
Blocks for batch-related consumption recording
Blocks for the integration of measuring devices and switches
Other components, for example, for time synchronization,
data buffering or data exchange with archives
Faceplates for presenting results and for entering values
(e.g. for configuration or from manual measured values)
Excel-based reports for allocating power data to cost centers,
for batch-related evaluation and for determining and presenting the duration curve
Exporting data to Excel

Siemens LV 10.1 2011

13/11

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
SIMATIC WinCC powerrate

Selection and ordering data


SIMATIC WinCC V 6.2 SP2/SP3 and V 7.0 SP1
- and related versions of STEP 7
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

SIMATIC WinCC powerrate V 3.0


Trial license

3ZS2 795-1CC30-0YG7

1 unit

276

0.200

3ZS2 795-1CC30-0YG0

1 unit

276

0.200

3ZS2 795-1CC30-0YE0

1 unit

276

0.200

Limited 30 day Engineering-/Runtime license

Unlimited Engineering-und AS-Runtime license1)


Also includes:
License for WinCC UserArchive
PAC3200 block library for SIMATIC WinCC

Upgrade from SIMATIC WinCC powerrate V 2.0 to V 3.0


Unlimited Engineering-und AS-Runtime license1)
Also includes:
License for WinCC UserArchive
PAC3200 block library for SIMATIC WinCC
1)

For operation on one WinCC OS (single workstation system or server) and


an automation system (AS). A license is required per WinCC single workstation system or server if using additional WinCC single workstation systems or servers.

More information
Information about using SIMATIC WinCC Powerrate
is available from
Siemens AG, Technical Support
Tel.: +49 (0) 911 895 7 222
Fax.: +49 (0) 911 895 7 223
www.siemens.com/automation/support-request
You can find further general information on the Internet at:
www.siemens.com/powermanagementsystem

13

* You can order this quantity or a multiple thereof.

13/12

Siemens LV 10.1 2011

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
SIMATIC PCS 7 Library PAC3200

Overview

Benefits
Full integration of SENTRON PAC3200 in the PCS 7 process
control system through PROFIBUS DPV1 using a certified
PCS 7 add-on module
Reading out and displaying device data
Inputting limit values for monitoring through the driver block
Resetting values on the device (min/max values)

Application
SIMATIC PCS 7 Library PAC3200 is used in all areas in which
PCS 7 is used. Full integration in PCS 7 means that there is no
need for a special system environment. Predefined modules and
symbols give you the assurance of building on tested and certified product components. In future the PAC4200 can also be
used as a measuring instrument.

The PCS 7 block library - SIMATIC PCS 7 Library PAC3200 - for


the SENTRON PAC3200 multifunction measuring instrument enables the seamless integration of the multifunction instrument in
the PCS 7 process world.
It comprises one driver block, one diagnostics block and the
faceplates. The blocks in the SIMATIC S7 supply energy data to
the faceplates in the user interface of the process control system, generate signals and guarantee connection to the maintenance system of PCS 7.
Faceplates
Faceplates serve as a user interface for operating and monitoring and enable technologically important values and functions of
the SENTRON PAC3200 to be displayed and performed as a
PCS 7 object.
Between the faceplates and the blocks as well as between the
blocks and the SENTRON PAC3200 there exist on the system
side bidirectional communication connections not only for displaying values in the faceplates but also for forwarding input
data to the device.
This makes the SENTRON PAC3200 power monitoring device an
integral component of PCS 7.

13

The operating systems supported are the same as those for the
SIMATIC PCS 7.

Selection and ordering data


SIMATIC PCS 7 V 6.1 SP3, PCS 7 V 7.0 SP1
and PCS 7 V7.1 SP1
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

SIMATIC PCS 7 Library PAC3200 1)


Engineering license

3ZS2 781-1CC10-0YG0

1 unit

133

0.250

3ZS2 781-1CC10-6YH0

1 unit

133

0.250

For operation on one PCS 7 OS (single workstation system or server) and


an automation system (AS).
When using additional PCS 7 OS devices, you need an engineering license
for each PCS 7 OS.
Runtime license
For operation on an additional AS

1)

For currently-supported SIMATIC PCS 7 versions see


http:/support.automation.siemens.com

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

13/13

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
3WL/3VL block library for SIMATIC PCS 7

Overview

Benefits
Full integration of SENTRON circuit breaker in the PCS 7 process control system through PROFIBUS DPV1 using a certified PCS 7 add-on module
Remote switching and monitoring
Reading out of maintenance information
Automatic information in case of overload, short-circuit and
faults
Reading out and displaying device data
Limit monitoring through the driver block
Resetting values on the device (min/max values)

Application
The 3WL/3VL block library for SIMATIC PCS 7 is used in all areas
in which PCS 7 is used. Full integration in PCS 7 means that there
is no need for a special system environment. Predefined modules and symbols give you the assurance of building on tested
and certified product components.
The 3WL/3VL PCS 7 block library for SENTRON circuit breaker
allows for the simple and quick integration of the SENTRON
circuit breaker into the PCS 7 process world.
It comprises one driver block, one diagnostics block and the
faceplates. The blocks in the SIMATIC S7 supply current, power
and energy data to the faceplates in the user interface of the process control system, generate signals and guarantee connection to the maintenance system of PCS 7.
Faceplates
Faceplates serve as a user interface for operating and monitoring and enable the SENTRON circuit breaker to be displayed
and performed simply as a PCS 7 object.
The 3WL/3VL block library for SIMATIC PCS 7 provides for continual plant transparency. Critical plant states are recognized
quickly and costs owing to outages avoided. System availability
is permanently increased
This transforms the SENTRON circuit breaker into an integral
component of PCS 7.

13

The operating systems supported are the same as those for the
SIMATIC PCS 7.

Selection and ordering data


SIMATIC PCS 7 V 6.1 SP1 and PCS 7 V 7.0 SP1
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

3WL/3VL block library for SIMATIC PCS 7


Engineering license

3ZS2 782-1CC10-0YG0

1 unit

133

0.250

3ZS2 782-1CC10-6YH0

1 unit

133

0.250

For operation on one PCS 7 OS (single workstation system or server) and


an automation system (AS).
When using additional PCS 7 OS devices, you need an engineering license
for each PCS 7 OS.
Runtime license
For operation on an additional AS

* You can order this quantity or a multiple thereof.

13/14

Siemens LV 10.1 2011

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SIMATIC
PAC3200 block library for SIMATIC WinCC
System requirements

Overview

The SENTRON PAC3200 block library for SIMATIC WinCC is


released for
WinCC V 6.2 SP2
WinCC V 7.0
WinCC V 7.0 SP1

SENTRON PAC3200 block library for SIMATIC WinCC

WinCC options AS-OS Engineering and Basic Process Control


must be installed. The block library is available for both S7-300
and S7-400. At least one S7 CPU317-2DP is required for use in
the S7-300 area. At least one S7 CPU414-2 is required for use in
the S7-400 area.
Supported operating systems are the same as for
SIMATIC WinCC.

Benefits

The SENTRON PAC3200 block library for SIMATIC WinCC


enables the seamless integration of the SENTRON PAC3200
multifunction measuring instrument in WinCC.
It comprises one driver block, one diagnostics block and the
faceplates. The blocks in the SIMATIC S7 supply energy data to
the faceplates in the user interface of WinCC, generate signals
and guarantee connection to the maintenance system of WinCC.

Full integration of the SENTRON PAC3200 in SIMATIC WinCC


through PROFIBUS DPV1 The block library is a certified
WinCC add-on module
Reading out and displaying device data
Inputting limit values for monitoring through the driver block
Resetting values on the device (min/max values)

Application
The SENTRON PAC3200 block library for SIMATIC WinCC is
used in all areas in which WinCC is used. Predefined blocks and
symbols give you the assurance of building on tested and certified product components. In future the PAC4200 can also be
used as a measuring instrument.

Faceplates
Faceplates serve as a user interface for operating and monitoring and enable technologically important values and functions of
the SENTRON PAC3200 to be displayed and performed in
WinCC.

The blocks work in a cyclic mode with fast updating of the important measured quantities and, in future, in an acyclic mode with
little space requirement in the process image.

Between the faceplates and the blocks as well as between the


blocks and the SENTRON PAC3200 there exist on the system
side bidirectional communication connections not only for displaying values in the faceplates but also for forwarding input
data to the device.
This makes the SENTRON PAC3200 power monitoring device an
integral component of WinCC.

13

Selection and ordering data


SIMATIC WinCC V 7.0 and WinCC V 7.0 SP 1
Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

SENTRON PAC3200 block library for SIMATIC WinCC1)


Engineering license

3ZS2 791-1CC10-0YG0

1 unit

133

0.250

3ZS2 791-1CC10-6YH0

1 unit

133

0.250

For operation on one PCS 7 OS (single workstation system or server) and


an automation system (AS).
When using additional WinCC OS devices, you need an engineering license
for each WinCC OS.
Runtime license
For operation on an additional AS

1)

For currently-supported SIMATIC PCS 7 versions see


http:/support.automation.siemens.com

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

13/15

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SENTRON
SENTRON powermanager

Overview

The SENTRON-based power management system is comprised


of a PC with the related power management software and with
the related devices which are connected directly to the PC
through Ethernet.
General goals of a power management system:
to identify savings potential
to reduce power costs
to ensure power availability
through transparency of the momentary conditions and through
comprehensive power assignments and evaluations.

13

The SENTRON powermanager PC-based power management


software
is an independent power management software
can be operated with a PC and measuring instruments with
Ethernet connection
is expandable from the simple standard application to
a fully flexible customer solution
is fully scalable with regard to the number of devices and to
the software's functions
Ensures the optimum integration of measuring instruments
from the SENTRON PAC range, SENTRON 3WL/3VL circuit
breakers and other devices

SENTRON powermanager is designed for:


collecting
monitoring
evaluating
presenting
archiving
power data from SENTRON PAC3100, PAC3200 and PAC4200
multifunction measuring instruments, SENTRON 3WL/3VL circuit
breakers, and any modbus-capable detecting devices.
"Expert" and "Web" option packs
The SENTRON powermanager standard package already covers the usual requirements. With this package the user receives
an easy-to-engineer power management software which enables the data detected by the measuring instruments to be
read out, presented, archived and processed in basic evaluations. With the "Expert" option pack the user receives full flexibility for the presentation of graphic interfaces (e.g. single line presentations) in order to integrate his own images and devices.
The data/images are displayed as standard using a Windows client which must be installed on the PC. The "Web" pack is offered
to meet the market's demands for web presentation.

Benefits

Transparency of power flows


Exact knowledge of the consumption profile
Increase of power efficiency
Optimization of power supply contracts
Compliance with contractual terms
Assignment of power costs to cost centers
Optimization of plant maintenance
Identification of critical plant conditions

In the SENTRON product family the user will find not only a
power management software in the form of SENTRON powermanager but also the matching hardware in the form of
SENTRON PAC measuring instruments and SENTRON 3WL/3VL
circuit breakers for realizing a complete power management
system. The components are optimally coordinated with each
other, e.g. special drivers for the SENTRON devices are integrated in the SENTRON powermanager software so that on the
one hand the power data acquisition can take place without any
great configuration effort and on the other hand the most important measured values or states are indicated by predefined displays.

13/16

Siemens LV 10.1 2011

This reduces the engineering work for the customer and gives
the user the assurance of knowing that the device functions are
optimally supported in the software.
The SENTRON powermanager software comprises a server/client software for the acquisition, processing, presentation and archiving of power data. These power data are supplied primarily
by multifunction measuring instruments (PAC) or 3WL/3VL circuit
breakers which are connected to the system through Ethernet.

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SENTRON
SENTRON powermanager

Application
Applications
The product offers a standard power management solution
which provides the user with the following basic functionality:
Collection of measured quantities from the devices
Presentation of the measured quantities from the devices in table form in a predefined standard view for
SENTRON PAC3100, PAC3200 and PAC4200 measuring instruments and 3WL/3VL circuit breakers
Free presentation of measured quantities possible, including
from non-Siemens devices using generic Modbus drivers

Archiving of measured quantities


Monitoring of status and limits, with generation of corresponding signals
Reserve curve display for visualizing the achieved data and
online data
Cost center reports based on predefined rates and the archived consumption data
OPC server
Configuration of the system including user management

System configuration
Operation & monitoring
Windows or web clients
Ethernet
Data processing
SENTRON powermanager server
Ethernet (Modbus)
Data detection
Measuring/protection devices

PAC3200

PAC4200

PAC3200

This standard solution is designed with cost-efficiency and simple system start-up in mind.
The "Expert" option pack is available for customers with broader
requirements particularly with regard to visualizing the status of
the entire power distribution. Using this option pack it is possible
to create any number of graphic images as single-line diagrams
and to add and interlink self-defined objects and have them respond to events, e.g. through object animation. In addition the
user can define his own devices using a device editor, which is
included in the delivery, and integrate them in the system. The
user even has the possibility of creating his own runtime scripts.
However, unlike the SENTRON powermanager software, the
"Expert" option pack requires a certain system know-how, which
can be acquired in special training courses.
The system is expandable of course to the extent that it allows
the customer to begin with the basic functionality of the
SENTRON powermanager and add the "Expert" option pack at a
later date. Existing data and configurations can still be used after upgrading.
System configuration
Integration of measuring instruments by means of predefined
device templates for the SENTRON PAC family and the
SENTRON 3WL/3VL circuit breakers
Easy integration of existing modbus-capable detecting
devices
Communication through Standard Ethernet
Integration of devices with RS485 interface (ModbusRTU)
through Modbus gateway, e.g. the SENTRON PAC4200 can
be used as gateway

SENTRON
3WL

SENTRON
3VL

I202_01389

Modbus RS485
PAC3100

Industries
Interesting for all industries because power efficiency through
strict monitoring and the resultant optimization measures plays a
key role throughout the manufacturing industry, in non-residential buildings, in the services sector and on infrastructure projects. This has an impact on competitiveness, particularly in view
of rising energy prices.
System requirements
Hardware requirements
Processor: Intel Pentium IV 2.8 GHz (or better)
RAM: min. 2 GB
Hard disk: min. 1 GB free
Graphics: VGA with min. 1280 x 1024 pixels with 16-bit color
intensity
Supported operating systems
Windows Vista: Business, Ultimate; SP1
Windows XP: XP with SP2/SP3
Windows 2003: Server 2003 Server (32-bit)
Supported Excel versions (required for reporting)
Excel 2000, Excel XP, Excel 2003, Excel 2007

Siemens LV 10.1 2011

13/17

13

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SENTRON
SENTRON powermanager

Selection and ordering data


Version

DT

Order No.

Trial lizense
 10 devices, incl. "Expert" and "Web" option pack
product full license limited to 30 days

Product full license, Lean


 10 devices

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.

3ZS2 711-0CC20-0YA7

1 unit

133

0.230

3ZS2 711-0CC20-0YA0

1 unit

133

0.230

Product full license, Standard


 50 devices

3ZS2 712-0CC20-0YA0

1 unit

133

0.230

Product full license, Advanced


 100 devices

3ZS2 713-0CC20-0YA0

1 unit

133

0.230

Product full license, Maximum


 200 devices

3ZS2 714-0CC20-0YA0

1 unit

133

0.230

Upgrade license
from Lean to Standard

3ZS2 712-0CC20-0YD0

1 unit

133

0.230

Upgrade license
from Standard to Advanced

3ZS2 713-0CC20-0YD0

1 unit

133

0.230

Upgrade license
from Advanced to Maximum

3ZS2 714-0CC20-0YD0

1 unit

133

0.230

Option pack "Up to 5 Clients"


Expansion up to 5 clients

3ZS2 710-3CC20-0YH0

1 unit

133

0.230

Option pack "From 5 to 10 Clients"


Expansion from 5 to 10 clients
(Requirement: Option pack "Up to 5 Clients")

3ZS2 710-4CC20-0YH0

1 unit

133

0.230

B
Option pack "Expert"
Option for creating and presenting any number of freely configured images

3ZS2 710-2CC20-0YH0

1 unit

133

0.230

B
Option pack "Web"
Option for access over the web (e.g. Internet Explorer) for up to 10 clients

3ZS2 710-1CC20-0YH0

1 unit

133

0.230

SENTRON powermanager V 2.0

Price advantages through system packages


SENTRON powermanager with SENTRON PAC3200 contains one
SENTRON powermanager product full license,
Lean (3ZS2711-0CC20-0YA0) and, depending on the package, three or five
or ten units of SENTRON PAC3200 (7KM2112-0BA00-3AA0)

13

SENTRON powermanager System3

3ZS2 813-2CC20-0YA0

1 unit

133

1.610

SENTRON powermanager System5

3ZS2 815-2CC20-0YA0

1 unit

133

2.530

SENTRON powermanager System10

3ZS2 817-2CC20-0YA0

1 unit

133

4.830

More information
You can find more information on the Internet at:
www.siemens.com/powermanagementsystem

* You can order this quantity or a multiple thereof.

13/18

Siemens LV 10.1 2011

Siemens AG 2011

Software
Configuring, Visualizing and Controlling with SENTRON
Switch ES Power

Overview

Benefits
Parameterization, documentation, operation and monitoring in
one software
Documentation of measured values and settings
Clear representation of all available parameters
All the available status information and measured values are
clearly displayed in dialog boxes
Software for SENTRON 3WL and SENTRON 3VL
Easy connection build-up through acyclic PROFIBUS DPV1
data traffic
Identical storage format for parameters with the Breaker Data
Adapter (BDA)
Easy-to-operate Windows interface
No programming knowledge required for operation
Object manager of Switch ES Power
Uniform data management for circuit breaker parameters
Automatic parameterization if components are replaced

Adjustment of parameter set A with Switch ES Power

Switch ES Power is the shared software platform for communication-capable SENTRON circuit breakers. This has the advantage
that all device-specific setting options are identical in terms of
appearance and handling.
Switch ES Power can be used to configure, document, operate
and monitor the SENTRON 3WL and SENTRON 3VL circuit
breakers through PROFIBUS DP.
More information can be found on the Internet at:
www.siemens.com/sentron

Selection and ordering data


Version

DT

Order No.

Price
per PU

PU
(UNIT,
SET, M)

PS*/
P. unit

PG

Weight
per PU
approx.
kg

Switch ES Power
Calibration, documentation, operation and monitoring of
A
SENTRON 3WL/3VL circuit breakers through PROFIBUS DP;
runs under Windows 95/98/NT/2000/XP Professional,
including online help, English or German selectable;
including Object Manager (OM) for Switch ES Power for integration in STEP7

3ZS2 311-0CC10-0YA0

1 unit

133

0.200

System requirements:
PROFIBUS card: CP5512, CP5611, CP5613 or CP5614
and MPI interface on PG7xx and its driver software,
see interactive Catalog CA01, CD-ROM drive
System requirements for OM Switch ES Power:
SIMATIC: S7, M7, C7, PCS 7
STEP 7: version 5.2 or higher
CD-ROM drive

* You can order this quantity or a multiple thereof.

Siemens LV 10.1 2011

13/19

13

Siemens AG 2011

Software
Notes

13

13/20

Siemens LV 10.1 2011

20

Siemens AG 2011

Appendix
20/2

Catalog Notes

20/3

Ordering Notes

20/5

UL Notes

20/6

ATEX Explosion Protection

20/7

Further Documentation

20/8

Standards and Approvals

20/28

Siemens Contacts

20/29

Solution Partners

20/30

Online Services

20/31

Service & Support

20/33

Comprehensive Support
from A to Z

20/34

Software Licenses

20/35

Subject Index

20/41

Order Number Index


incl. Export Markings

20/52

Terms and Conditions of Sale and


Delivery

Siemens LV 10.1 2011

20

Siemens AG 2011

Appendix
Catalog notes

Overview
Trademarks

Symbols

All product designations may be registered trademarks or product names of Siemens AG or supplier companies whose use by
third parties for their own purposes may violate the rights of the
owner.

The symbols used in this catalog are listed below. These symbols are use in conjunction with an orange background to mark
special selection criteria (e.g. connections, types of coordination, etc.).

Amendments
All technical data, dimensions and weights are subject to
change without notice unless otherwise specified on the pages
of this catalog.
Dimensions
All dimensions are in mm.
Images
The illustrations are not binding.
Technical data
The technical data in the catalog are for general information. The
instruction manuals and the operating instructions on the products must be observed during assembly, operation and maintenance.
Further technical information is available at
www.siemens.com/lowvoltage/support
under Product List:
- Technical specifications
under Entry List:
- Updates
- Download
- FAQ
- Manuals
- Characteristic curves
- Certificates
Configurators can be found under
www.siemens.com/lowvoltage/configurators
Assembly, operation and maintenance
The instruction manuals and the operating instructions on the
products must be observed during assembly, operation and
maintenance.

20

20/2

Siemens LV 10.1 2011

Connections
Screw terminals
Ring terminal lug connection

Switching capacity of 3WL circuit breakers


N

ECO switching capacity


(Icu up to 55/66 kA at 500 V)

Standard switching capacity


(Icu up to 66/80 kA at 500 V)

High switching capacity


(Icu up to 100 kA at 500 V)

Very high switching capacity


(Icu up to 150 kA (3-pole)/130 kA (4-pole)
at 500 V)

DC

Switching capacity for DC current

Switching capacity of 3VL circuit breakers


N

Standard switching capacity


(Icu up to 55 kA at 415 V)

High switching capacity


(Icu up to 70 kA at 415 V)

Very high switching capacity


(Icu up to 100 kA at 415 V)

Siemens AG 2011

Appendix
Ordering notes

Logistics
General

Packaging, packing units

With regard to delivery service, communications and environmental protection, our logistics service ensures "quality from the
moment of ordering right through to delivery". By designing our
infrastructure according to customer requirements and implementing electronic order processing, we have successfully optimized our logistics processes.

The packaging in which our equipment is dispatched provides


protection against dust and mechanical damage during transport, thus ensuring that all our products arrive in perfect condition.

We are proud of our personal consulting service, on-time deliveries and 1-day transport within Germany.
To this end, we supply the preferred types marked with }
ex works.
We regard the DIN ISO 9001 certification and consistent quality
checks as an integral part of our services.
Electronic order processing is fast, cost-efficient and error-free.
Please contact us if you want to benefit from these advantages.

We select our packaging for maximum environmental compatibility and reusability (e.g. crumpled paper instead of polystyrene
chips for protection during transport in packages up to 32 kg)
and, in particular, with a view to reducing waste.
With our multi-unit packaging and reusable packaging, we offer
you specific types of packaging that are both kind to the environment and tailored to your requirements:
Your advantages at a glance:
Lower order costs.
Cost savings through uniform-type packaging: low/no disposal costs.
Reduced time and cost thanks to short unpacking times.
"Just-in-time" delivery directly to the production line helps reduce stock: cost savings through reduction of storage area.
Fast assembly thanks to supply in sets.
Standard Euro boxes - corresponding to the Euro pallet modular system - suitable for most conveyor systems.
Active contribution to environmental protection.
Unless stated otherwise in the "Selection and ordering data" of
this catalog, our products are supplied individually packed.
For small parts/accessories, we offer you economical packaging units as standard packs containing more than one
item, e.g. 5, 10, 50 or 100 units. It is essential that whole number multiples of these quantities be ordered to ensure satisfactory quality of the products and problem-free order processing.
The products are delivered in a neutral carton. The label includes warning notices, the CE mark, the open arrow recycling
symbol, and product description information in English and
German. In addition to the Order No. (MLFB) and the number of
items in the packaging, the Instr. Order No. is also specified for
the operating instructions. It can be obtained from your local
Siemens representative (you will find a list of your local Siemens
representatives at www.siemens.com/automation/partner).
The device Order No. of most devices can also be acquired
through the EAN barcode to simplify ordering and storage logistics.
The Order Nos. and EAN codes are assigned electronically in
the master data of the products for low-voltage power distribution and electrical installation.

Siemens LV 10.1 2011

20/3

20

Siemens AG 2011

Appendix
Ordering notes

Overview
Ordering special versions

Ordering very small quantities

When ordering products that differ from the standard versions


listed in the catalog, "Z" must be added to the Order No. indicated and the required features must be specified using alphanumeric order codes or plain text.

When small orders are placed, the costs associated with order
processing are greater than the order value. We therefore recommend that you combine several small orders. Where this is
not possible, we regret that we are obliged to make a small processing charge: for orders with a net goods value of less than
250 we charge an 20 supplement to cover our order processing and invoicing costs.

Explanations on the Selection and Ordering Data


Delivery time class (DT)
Preferred types are device types that can be delivered immediately ex works, i.e. they are dispatched
within 24 hours.

DT

Meaning

Preferred type

Two workdays

One week

Three weeks

Six weeks

On request

Normal quantities of the products are usually delivered within the specified time following receipt of your
order at our branch.
In exceptional cases, the actual delivery time may differ from that specified.
The delivery times apply up to the ramp at Siemens AG (products ready for dispatch).
The transport times depend on the destination and type of shipping. The standard shipping time for Germany is one day.
The delivery time classes specified here represent the state at 10/2010. They are permanently optimized.
Up-to-date information can be found at www.siemens.com/industrymall.

Price units (PU)


The price unit defines the number of units, sets or meters to which the specified price and weight apply.

PS/P. unit (packaging size/packaging unit)


The packaging size / packaging unit defines the number, e.g. of units, sets or meters, for outer packaging.
The first digit in the PS/P. unit column (packaging size/packaging unit) indicates the minimum order quantity. You can only order this
specified quantity or a multiple thereof.
The second digit in the PS/P. unit column (packaging size/packaging unit) specifies the number of units contained in larger packaging
(e.g. in a carton). You must order this quantity or a multiple thereof if you want the item to be delivered in a larger packaging quantity.
Examples:
PS/P. unit

Meaning

1 unit

You can order one item or a multiple thereof.

5 units

For example, five units are packed in a bag. Because the bags cannot be opened, you can only order a multiple of
the quantity contained in the bag: 5, 10, 15, 20 etc.

5/100 units

One carton contains (for example) 20 bags, each containing 5 units, i.e. a total of 100 units. If only cartons are available for delivery, you need to order a multiple of the carton quantity: 100, 200, 300, etc.
Ordering a quantity of 220 units, would produce the following delivery: two cartons, each containing 100 units
(= 200 units) and 4 bags, each containing 5 units (= 20 units).

Price groups (PG)


Each product is assigned to a price group.

Weight
The defined weight is the net weight in kg and refers to the price unit (PU).

Examples
DT Order No.

20

20/4

5SW3 300

Price
PU
per PU (UNIT,
SET,
M)

PS/
P. unit

PG

DT Order No.

1 1/10 units

008

5SW3 313

Price
PU
per PU (UNIT,
SET,
M)

PS/
P. unit

PG

1 set*

008

DT:

Preferred type

DT:

A = two workdays

PU:

One unit (on which price is based)

PU:

One set, i.e. 12 units (on which price is based)

PS/P. unit: 1 = minimum order quantity / 10 = quantity per


carton

PS/P. unit: The minimum order quantity is one set

PG:

* The selection and ordering data specifies that one set contains 12 units

008

Siemens LV 10.1 2011

PG:

008

Siemens AG 2011

Appendix
UL notes

Low-voltage power distribution and electrical installation technology.


The secrets of UL. You have our support.
Our products for low-voltage power distribution and electrical installation are designed not only for the IEC market. Numerous
devices have both UL and IEC approval. This makes it easier for
manufacturers of switchgear and controlgear assemblies to enter the North American market.
Exports to North America require special approvals which differ
from the IEC directives. On the IEC market, directives define only
the essential functions of a system. The technical details are not
listed. By contrast, directives on the American market go into the
details of how to carry out the installation work etc.
For OEMs and machine manufacturers it is important to know the
main differences between the two technical worlds and to work
together respectively with manufacturers and suppliers who
have the right products and know-how.
Siemens is a strong partner in this case. Our know-how extends
from the production of UL-approved devices to the wiring of control cabinets according to UL directives.
These UL requirements are already taken into account when designing our devices for low-voltage power distribution and electrical installation. They are developed not only for the IEC market
but also for the UL market.

In addition to looking in this catalog you should also check out


our Catalog LV 16 "Controls and Components for Applications
according to UL" for UL-specific products:
SIRIUS 3RV17 and 3RV18 circuit breakers
Components for SENTRON 8US distribution systems
SENTRON 3WL5 and 3VL circuit breakers
ALPHA distribution boards and terminal blocks
BETA low-voltage circuit protection

We have been working with UL (Underwriters Laboratories


Inc.), the leading technical certification company in the USA,
since 1969. We are also glad to share our knowledge with you in
the form of training courses.

Take a look at our range of products and convince yourself. Or


simply click on

With our UL-certified products for low-voltage power distribution


and electrical installation you are on the safe side and can build
control cabinets according to UL standard easily and quickly.

Here you will find information on for example UL standards, UL


classification and a number of technical particularities of UL.

UL-certified products to be found in this catalog include for example:


SENTRON circuit breakers, motor starter protectors and switch
disconnectors
ALPHA FIX terminal blocks
SENTRON busbar systems
Miniature circuit breakers and fuses from the BETA low-voltage
circuit protection range

www.siemens.com/lowvoltage/ul-europe

Under "UL Overview/Standards and Approvals" we provide a


summary of the available products and product groups. A table
lists the UL standards to which the products conform and contains links to the corresponding UL reports.
Under "Portfolio" we round off with a list of our most relevant
products for low-voltage power distribution and electrical installation as well as for low-voltage controls (including links to the respective Internet product pages).
Simply click on the navigation bar and go on a UL discovery
tour!

Siemens LV 10.1 2011

20/5

20

Siemens AG 2011

Appendix
ATEX explosion protection

Overview
In many industries the production, processing, transport and
storage of combustible substances are accompanied by escaping gases, vapor or spray which find their way into the environment. Other processes result in combustible dust. Together with
the oxygen in the air, the result can be an explosive atmosphere
which will explode if ignited.
Serious injury to persons and damage to property can result particularly in the chemical and petrochemical industry, mineral oil
and natural gas production, mining, mills (e.g. grain, solid materials) and many other sectors.
To guarantee the maximum possible safety in these areas, the
legislators of most countries have drawn up requirements in the
form of laws, regulations and standards. In the course of globalization, great progress has been made with regard to uniform directives for explosion protection.
With Directive 94/9/EC, the European Union laid the foundations
for complete harmonization by requiring that all new devices as
from 1st July 2003 have to be approved in accordance with this
directive.

20

20/6

Siemens LV 10.1 2011

In this catalog, special attention is drawn to devices which comply with the ATEX Directive. However, it does not replace intensive study of the relevant fundamentals and directives when
planning and installing electrical systems.

Siemens AG 2011

Appendix
Further documentation

Overview
We regard product support as just as important as the products
and systems themselves.
Visit our site on the Internet for a comprehensive offering of support for low-voltage power distribution and electrical installation
products, such as
Operating instructions and manuals for direct download
Online registration for seminars and events
Up-to-date answers to your queries and problems
Software upgrades and updates for fast download
Telephone assistance in more than 190 countries
Photos and graphics for external use
and much, much more - all conveniently and easily accessible.
Address:
www.siemens.com/lowvoltage
You will find regularly updated information material such as catalogs, customer magazines, brochures and trial versions of software for low-voltage power distribution and electrical installation
on the Internet at:
www.siemens.com/lowvoltage/infomaterial
Here you can order your copy of the available documentation or
download it in common file formats (PDF, ZIP).

For your configuration systems we can provide technical and


graphic data in electronic form for the range of low-voltage
power distribution and electrical installation products:
CAx online generator
For the further processing of low-voltage power distribution and
electrical installation products in CAE/CAD systems the online
generator provides:
Technical product master data in CSV and Excel format
Graphic product data
- 2D dimensional drawings in DXF format (other formats optional)
- 3D models in STEP format
- Internal circuit diagrams
- EPLAN electric P 8 macros
Documentation in the form of PDF files
- Product data sheets
- Manuals
- Operating instructions
- Characteristics
- Certificates
Product photos
Texts for tenders in GAEB and Text format
www.siemens.com/cax

Siemens LV 10.1 2011

20/7

20

Siemens AG 2011

Appendix
Standards and approvals

Overview
Approvals, test certificates, characteristic curves
An overview of the certificates available for low-voltage power
distribution and electrical installation products along with more
technical documentation can be consulted daily on the Internet
at:
www.siemens.com/lowvoltage/support

Product support: Approvals / Certificates

Product support: Characteristic curves

Product standards (excerpt)

20

IEC

EN

DIN VDE

Title

60947-1
60947-2
60947-3

60947-1
60947-2
60947-3

----

Low-voltage controlgear and switchgear General rules


Circuit breakers
Switches, disconnectors, switch disconnectors and fuse-combination units

60947-4-1
60947-4-2
60947-4-3

60947-4-1
60947-4-2
60947-4-3

----

Contactors and motor starters Electromechanical contactors and motor starters


Contactors and motor starters Semiconductor motor controllers and starters, soft starters
Contactors and motor starters AC semiconductor controllers and contactors for non-motor loads

60947-5-1
60947-5-2
60947-5-3

60947-5-1
60947-5-2
60947-5-3

----

60947-5-5

60947-5-5

--

60947-5-6

60947-5-6

--

60947-5-7

60947-5-7

--

60947-5-8
60947-5-9

60947-5-8
60947-5-9

---

Control circuit devices and switching elements Electromechanical control circuit devices
Control circuit devices and switching elements Proximity switches
Control circuit devices and switching elements Requirements for proximity devices with
defined behaviour under fault conditions
Control circuit devices and switching elements Electrical emergency stop device with mechanical latching function
Control circuit devices and switching elements DC interface for proximity sensors and
switching amplifiers (NAMUR)
Control circuit devices and switching elements Requirements for proximity switches with
analog output
Control circuit devices and switching elements Three-position enabling switches
Control circuit devices and switching elements Flow rate switches

60947-6-1
60947-6-2

60947-6-1
60947-6-2

---

Multiple function equipment Transfer switching equipment


Multiple function equipment Control and protective switching devices (or equipment) (CPS)

60947-7-1
60947-7-2
60947-7-3

60947-7-1
60947-7-2
60947-7-3

----

Ancillary equipment Terminal blocks for copper conductors


Ancillary equipment Protective conductor terminal blocks for copper conductors
Ancillary equipment Safety requirements for fuse terminal blocks

60947-8

60947-8

--

Control units for built-in thermal protection (PTC) for rotating electrical machines

62026-2

50295

--

Controller and device interface systems. Actuator-Sensor Interface (AS-i)

60269-1
60269-4

60269-1
60269-4

---

Low-voltage fuses General requirements


Low-voltage fuses Supplementary requirements for fuse-links for the protection of semiconductor
devices

60050-441

--

--

International Electrotechnical Vocabulary. Switchgear, controlgear and fuses

60439-1
61439-1
61439-2

60439-1
---

----

--

50274

--

61140

61140

--

Low-voltage switchgear and controlgear assemblies Type-tested and partially type-tested assemblies
Low-voltage switchgear and controlgear assemblies General rules
Low-voltage switchgear and controlgear assemblies Particular requirements for busbar trunking
systems (busways)
Low-voltage switchgear and controlgear assemblies Protection against electric shock - Protection
against unintentional direct contact with hazardous live parts
Protection against electric shock - Common aspects for installation and equipment

60664-1

60664-1

--

20/8

Siemens LV 10.1 2011

Insulation coordination for electrical equipment within low-voltage systems


Principles, requirements and tests

Siemens AG 2011

Appendix
Standards and approvals
IEC

EN

DIN VDE

Title

60204-1
-60079-14

60204-1
50178
60079-14

----

60079-2

60079-2

--

Safety of machinery Electrical equipment of machines General requirements


Electronic equipment for use in power installations
Explosive atmospheres Part 14: Electrical installations design, selection and erection
Installing electrical apparatus in potentially explosive gas atmospheres (except mining)
Explosive atmospheres Part 2: Equipment protection by pressurized enclosures "p"

61810-1
61812-1
60999-1

61810-1
61812-1
60999-1

----

Electromechanical elementary relays Part 1: General requirements


Specified time relays for industrial use Part 1: Requirements and tests
Connecting devices Electrical copper conductors Safety requirements for screw-type and screwlesstype clamping units Part 1: General requirements and particular requirements for clamping units for conductors from 0.2 mm2 to 35 mm2

61558-1

61558-1

0570-11)

Safety of power transformers, power supplies, reactors and similar products


- Part 1: General requirements and tests

61558-2-1

61558-2-1

0570-2-11)

61558-2-2

61558-2-2

0570-2-21)

61558-2-4

61558-2-4

0570-2-41)

61558-2-6

61558-2-6

0570-2-61)

61558-2-9

61558-2-9

0570-2-91)

61558-2-12
61558-2-13

61558-2-12
61558-2-13

0570-2-121)
0570-2-131)

61558-2-15
61558-2-20

61558-2-15
61558-2-20

0570-2-151)
0570-2-201)

- Part 2-1: Particular requirements and tests for separating transformers and power supplies
incorporating separating transformers for general applications
- Part 2-2: Particular requirements and tests for control transformers and power supplies
incorporating control transformers
- Part 2-4: Particular requirements and tests for isolating transformers and power supply units
incorporating isolating transformers
- Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units
incorporating safety isolating transformers
- Part 2-9: Particular requirements and tests for transformers and power supply units for class III
handlamps for tungsten filament lamps
- Part 2-12: Particular requirements for constant voltage transformers
- Part 2-13: Particular requirements and tests for auto transformers and power supply units
incorporating auto transformers
- Part 2-15: Particular requirements for isolating transformers for the supply of medical locations
- Part 2-20: Particular requirements and tests for small reactors

62041

62041

0570-101)

Power transformers, power supply units, reactors and similar products EMC requirements

60076-11
--

60076-11
--

-0552

Power transformers Part 11: Dry-type transformers


Standards for variable-ratio transformers with moving contacts perpendicular to the coiling direction

61000-4-1

61000-4-1

--

61000-6-3

61000-6-3

--

61000-6-4

61000-6-4

--

Electromagnetic compatibility (EMC) Part 4-1: Testing and measurement techniques Overview
of IEC 61000-4 series
Electromagnetic compatibility (EMC) Part 6-3: Generic standards Emission standard for
residential, commercial and light-industrial environments
Electromagnetic compatibility (EMC) Part 6-4: Generic standards Emission standard for
industrial environments

60044-1

60044-1

--

1)

Instrument transformers Part 1: Current transformers

VDE classification.

UL

CSA C22.2 ASME

JIS

Title

506
508
489
1012

-----

-----

-----

Specialty transformers
Industrial control equipment
Molded case circuit breakers, molded case switches and circuit breaker enclosures
Power units other than CLASS 2

1561
5085
60601-1

----

----

----

1604
-1059
-486A-486B --

----

----

Dry-type general purpose and power transformers


Low-voltage transformers
Medical electrical equipment, Part 1: General requirements for safety (IEC 60601, EN 60601,
VDE 0750-1)
Electrical equipment for use in CLASS I and II, Division 2 and CLASS III hazardous (Classified) locations
Terminal blocks
Wire connectors

486E

--

--

--

Equipment wiring terminals for use with aluminum and/or copper conductors

50

--

--

--

Enclosures for electrical equipment. Non-environmental considerations

-----

No. 66
No. 14
No. 5
No. 107-1

-----

-----

Specialty transformers
Industrial control equipment
Molded case circuit breakers, molded case switches and circuit breaker enclosures
General use power supplies

--

--

A17.5 / B 44.1 --

--

--

--

Elevator and escalator electrical equipment

C 8201-4-1 Low-voltage switchgear and controlgear; Contactors and motor-starters

Siemens LV 10.1 2011

20/9

20

Siemens AG 2011

Appendix
Standards and approvals

Quality management

Certificates

The quality management system of our I BT LV Business Unit


complies with the international standard EN ISO 9001.
The products and systems listed in this catalog are marketed using a VDE-approved quality management system according to
ISO 9001.
VDE certificate
Siemens AG
Industry Sector
Building Technologies Division
Low Voltage Distribution (I BT LV)
Reg. No.: 40017/QM/03.06

Information on the certificates available (CE, UL, CSA, FM, shipping authorizations) for low-voltage power distribution and electrical installation products can be found on the Internet at:
www.siemens.com/lowvoltage/support
In the Entry List you can use the certificate type (general product
approval, explosion protection, test certificates, shipbuilding,...)
as a filter criterion.

Approval requirements valid in different countries


Siemens low-voltage switchgear and controlgear are designed,
manufactured and tested according to the relevant German
standards (DIN and VDE), IEC publications and European standards (EN) as well as CSA and UL standards. The standards assigned to the single devices are stated in the relevant parts of
this catalog.
As far as is economically viable, the requirements of the various
regulations valid in other countries are also taken into account in
the design of the equipment.
In some countries (see table below), an approval is required for
certain low-voltage switchgear and controlgear components.
Depending on the market requirements, these components have
been submitted for approval to the authorized testing institutes.

In some cases, CSA for Canada and UL for the USA only approve special switchgear versions. Such special versions are
listed separately from the standard versions in the individual
parts of this catalog.
For this equipment, partial limitations of the maximum permissible voltages, currents and ratings can be imposed, or special
approval and, in some cases, special identification is required.
For use on board ship, the specifications of the marine classification societies must be observed (see table below). In some
cases, they require type tests of the components to be approved.
The present state of approval is shown in the "Overview of approved equipment" tables on 20/12 to 20/27.

Testing bodies, approval identification and approval requirements


Country

Canada 1)

USA 1)

China

Government-appointed or private, officially


recognized testing bodies

CSA UL
(USA)

UL

CQC

Approval symbol

Approval requirements

Remarks

UL and CSA are authorized to grant approvals according to Canadian CCC


or US regulations. Please note: these approvals are frequently not recognized and additional approval often has to be obtained from the
national testing authority.

c u cU
c UUS
c uUS

For more information about UL and CSA see 20/11.


1)

20

For guide numbers and file numbers for the approvals, visit our website at
www.siemens.com/lowvoltage/support

20/10

Siemens LV 10.1 2011

U
c UUS
c uUS
+

Siemens AG 2011

Appendix
Standards and approvals

Marine classification societies


Country

Germany

United
Kingdom

France

Norway

CIS

Italy

Poland

USA

Name

Germanischer
Lloyd

Lloyds
Register of
Shipping

Bureau
Veritas

Det Norske
Veritas

Russian
Maritime
Register of
Shipping

Registro
Italiano
Navale

Polski
Rejestre
Statkw

American
Bureau of
Shipping

Codes

GL

LRS

BV

DNV

RMRS

RINA

PRS

ABS

CE mark of conformity
Manufacturers of products which fall within the subject area to
which EC directives apply must identify their products, operating
instructions or packaging with a CE mark.
The CE mark confirms that a product fulfills the appropriate basic requirements of all pertinent directives. The mark is a mandatory requirement for putting products into circulation throughout
the EC.

All the products in this catalog are in conformance with the EC


directives and bear the CE mark.
Low-voltage directive
EMC directive
Machinery directive
Ex protection directive
The CE mark of conformity: >.

Accident prevention
Test certificates and approvals from the BIA (German statutory
industrial accident insurance institution in Bonn) and from SUVA
(Swiss institute for accident prevention) are available for some
devices in safety control systems. For details, see the respective
product descriptions.

Special standards, for example the USA and Canada


In the USA and Canada, for machine tools and processing machines in particular, supply lines are laid using rubber insulated
cable enclosed in heavy-duty steel piping similar to that used for
gas or water pipe systems.
The tubing system must be completely watertight and electrically conductive (especially sleeving and elbows). Since the
tubing system can also be grounded, the cable entries of enclosed units equipped with heavy-gauge or metric threads must
be fitted with metal adapters between these threads and the
tube thread. The necessary adapters are specified for the
switchgear as accessories; they should be ordered separately
unless otherwise specified.

The abbreviations are harmonized with IEC 60947-5-1 Appendix


1 Table A.1 and correspond to the stated utilization categories.
For various switching devices detailed in the catalog, a note has
been included to the effect that, above a certain voltage, the
auxiliary switches/auxiliary contacts can only be used if they
have the same polarity. This means that the input terminals can
only be connected to the same pole of the actuating voltage,
e.g. "600 V AC above 300 V AC same polarity".

Low-voltage switchgear and controlgear for auxiliary circuits


(e.g. contactor relays, commanding and signaling devices and
auxiliary switches/auxiliary contacts in general) are generally
only approved by CSA and UL for "Heavy Duty" or "Standard
Duty" and are identified either with these specifications in addition to the maximum permissible voltage or by using an abbreviation.
Different features of UL approvals (for USA and Canada)
Recognized Component

Listed Product

Devices are identified on the rating plate


using the "UL recognition mark":
U, cUUS
USA:
Canada:
cU, cUUS

Devices are identified using the "UL listing mark" on the rating plate
Canada: cu LISTED 165 C
e.g. USA: u LISTED 165 C
IND. CONT. EQ.
IND. CONT. EQ.
(165 C stands for: Siemens, I IA CD Division, Amberg plant)

Devices are approved as modules for "factory wiring", i.e.:


as devices for installation in control systems, which are selected, installed,
wired and tested entirely by trained personnel in factories, workshops or
elsewhere, according to the operating conditions.

Devices are approved for "field wiring", i.e.:


As devices for installation in control systems, which are completely wired by
trained personnel in factories, workshops or elsewhere.
As single devices for sale in retail outlets in the USA/Canada.

If devices are u or cu approved as "listed products", they are also approved as U or cU "recognized components".

For more information about UL and CSA see 20/10.

Siemens LV 10.1 2011

20/11

20

Siemens AG 2011

Appendix
Standards and approvals

Special standards, for example Russia, Australia and China


CCC approval

GOST approval for Russia

Since August 1, 2003, CCC approval is required for many products that are marketed in China.
A GOST approval is required for all products that are to be sold
in Russia. The GOST mark has been obligatory on the packaging of all devices since mid-1998.
All devices delivered to any part of the Russian Federation must
have this customs certification.
C-Tick licensing for Australia

The C-Tick license is required for marketing Siemens components in Australia. Electronic devices must provide proof of EMC
clearance in Australia, similar to the CE mark of conformity laid
down by the EMC directive applicable in the EC and bear the "CTick" mark. These requirements have been in force since October 1st, 1999.

Type overview of approved devices


Chapter 1 Air Circuit Breakers
Approvals
Application in

Canada
1) 2)

Marine classifications
USA
1)

1)

China

s cUUS u cuUS U CCC


SENTRON WL circuit breakers up to 6300 A (ACB)

Certification
3WL1

Germany

United
Kingdom

France

Norway

CIS

Italy

Poland

USA

GL

LRS

BV

DNV

RMRS

RINA

PRS

ABS

--

--

--

--

--

--

--

+3)

--

--

--

--

--

--

--

--

--

UL/CSA version
3WL5

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

-1)

For guide numbers and file numbers for the approvals, visit our website at
www.siemens.com/lowvoltage/support.

2)

cu and cU approvals are available in accordance with US approval.

3)

CSA attestation according to IEC 60947-2.

Chapter 2 Molded Case Circuit Breakers


Approvals
Canada

Marine classifications
Germany

United
Kingdom

France

Norway

CIS

Italy

Poland

USA

s cUUS u cuUS U CCC


SENTRON VL circuit breakers up to 1600 A (MCCB)

GL

LRS

BV

DNV

RMRS

RINA

PRS

ABS

3VL1/2/3/4
3VL5/6/7/8
3VL9

Application in

1) 2)

USA
1)

1)

China

Certification

----

----

----

----

----

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

----

----

----

+
+
+

+
+
+
+

-----

+
+
+
+

-----

+
+
+3)
+3)

-----

-----

-----

-----

-----

-----

-----

-----

UL/CSA version
3VL1
3VL2/3/4/4X
3VL6/7/8
3VL9

+ Standard version approved.


-- Not yet submitted for approval.

U approval not required because u approved.

Further certifications and approvals available on request.

20

20/12

Siemens LV 10.1 2011

1)

For guide numbers and file numbers for the approvals, visit our website at
www.siemens.com/lowvoltage/support.

2)

cu and cU approvals are available in accordance with US approval.

3)

Not all versions are approved. Request required.

Siemens AG 2011

Appendix
Standards and approvals
Chapter 3 Miniature Circuit Breakers
Application in

Germany,
Europe

Belgium

France

Italy

Russia

USA, Canada

China

Approvals

VDE

CEBEC

LCIE (NF)

IMQ

GOST

Fire Safety
Protection

CCC

Miniature circuit breakers


5SL
5SY4
5SY7

+
+1)2)
+

+
---

----

-+
+

+
+
+

+
+
+

-+
+

----

-+
+

5SY8
5SY5, universal current
5SP4
5SP5

-+
+
+

-----

-----

-----

+
+
+
+

+
+
+
+

+
-+
--

-----

-+
+
--

--

--

--

--

--

--

--

--

--

--

Miniature circuit breakers with plug-in terminal


5SJ6 . . .-.KS

Miniature circuit breakers 1+N


5SY6 0. .

Miniature circuit breakers according to UL 489 and IEC


5SJ4 . . .-.HG40
5SJ4 . . .-.HG41
5SJ4 . . .-.HG42

----

----

----

----

+
+
+

----

----

+
+
+

----

----

----

----

+
+
--

+
+
+

+
+
--

--+

+
+
--

--

--

--

--

--

--

--

--

--

--

--

--

Additional components
5ST3 01.
5ST3 02.
5ST3 0. .-0HG

+
+
--

Main miniature circuit breakers


5SP3

Circuit breaker terminals


5SK9

--

+ Standard version approved.

1)

Characteristic A, VDE-tested.

-- Not yet submitted for approval.

2)

All types with rated current In  63 A.

Further certifications and approvals available on request.


Application in

Germany

France

United Kingdom

Italy

Norway

Marine classifications

GL

BV

LRS

RINA

DNV

Miniature circuit breakers


Characteristic

5SY4
5SY7
5SP4

+
+
+

+
+
+

--+

+1)
+
--

+1)
+
--

+1)
+
--

+1)
+
+

+1)
+
+

--+

+1)
+
--

+1)
+
--

+1)
+
--

+1)
+
--

+1)
+
--

+1)
+
--

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.


1)

All types with rated current In  63 A.

Siemens LV 10.1 2011

20/13

20

Siemens AG 2011

Appendix
Standards and approvals
Chapter 4 Residual Current Protective Devices
Application in

Germany,
Europe

Belgium

France

Italy

Austria

Spain

Russia

China

Approvals

VDE

CEBEC

LCIE (NF)

IMQ

VE

AENOR

GOST

Fire Safety
Protection

CCC

5SM3 . . .-6
5SM3 111-6
5SM3 311-6
5SM3 312-6

+
+
+

+
+
+

----

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

5SM3 314-6
5SM3 316-6
5SM3 317-6

+
+
+

+
+
+

----

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

5SM3 412-6
5SM3 414-6
5SM3 416-6

+
+
+

+
+
+

----

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

5SM3 417-6
5SM3 612-6
5SM3 614-6

+
+
+

+
+
+

----

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

+
+
+

5SM3 616-6
5SM3 617-6
5SM3 416-8

+
+
+

+
+
--

----

+
+
--

+
+
+

+
+
+

+
+
+

+
+
+

+
+
--

5SM3 417-8
5SM3 614-8
5SM3 616-8
5SM3 617-8

+
+
+
+

-+
---

-----

-----

-+
+
--

--+
+

+
+
+
+

+
+
+
+

-----

5SM3 . . .-6KK
5SM3 315-6KK
5SM3 318-6KK
5SM3 415-6KK

+
+
+

----

----

----

----

+
+
+

+
+
+

+
+
+

----

5SM3 418-6KK
5SM3 615-6KK
5SM3 618-6KK

+
+
+

----

----

----

----

+
---

+
+
+

+
+
+

----

5SM3 . . .-6KK01
5SM3 312-6KK01
5SM3 314-6KK01
5SM3 316-6KK01

+
+
+

----

----

+
+
--

----

+
+
+

+
+
+

+
+
+

+
+
--

5SM3 317-6KK01
5SM3 616-6KK01
5SM3 617-6KK01

+
+
+

----

----

----

----

-+
--

+
+
+

+
+
+

----

5SM3 . . .-6KK12
5SM3 312-6KK12
5SM3 314-6KK12
5SM3 316-6KK12
5SM3 317-6KK12

+
+
+
+

+
+
---

-----

+
+
+
+

-----

-----

+
+
+
+

+
+
+
+

+
-+
+

5SM3 . . .-6KL
5SM3 111-6KL
5SM3 311-6KL
5SM3 312-6KL

+
+
+

----

+
+
+

----

----

----

+
+
+

+
+
+

----

5SM3 314-6KL
5SM3 316-6KL
5SM3 317-6KL

+
+
+

----

+
+
--

----

----

----

+
+
+

+
+
+

----

5SM3 412-6KL
5SM3 414-6KL
5SM3 416-6KL
5SM3 417-6KL

+
+
+
+

-----

-+
+
--

-----

-----

-----

+
+
+
+

+
+
+
+

-----

5SM3 612-6KL
5SM3 614-6KL
5SM3 616-6KL
5SM3 617-6KL

+
+
+
+

-----

+
+
+
--

-----

-----

-----

+
+
+
+

+
+
+
+

-----

5SM3 61.-8KL
5SM3 614-8KL
5SM3 616-8KL

+
+

---

---

---

+
+

---

+
+

+
+

---

RCCBs, type A, 2-pole

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

20

20/14

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Belgium

France

Italy

Austria

Spain

Russia

China

Approvals

VDE

CEBEC

LCIE (NF)

IMQ

VE

AENOR

GOST

Fire Safety
Protection

CCC

5SM3 . . .-6
5SM3 342-6
5SM3 344-6
5SM3 345-6

+
+
--

+
+
--

----

+
+
--

+
+
--

+
+
--

+
+
+

+
+
+

+
+
--

5SM3 346-6
5SM3 347-6
5SM3 348-6

+
+
--

----

+
---

+
+
--

+
---

+
+
+

+
+
+

+
---

5SM3 444-6
5SM3 445-6
5SM3 446-6

+
-+

+
+

----

+
-+

+
-+

+
-+

+
+
+

+
+
+

+
-+

5SM3 448-6
5SM3 642-6
5SM3 644-6

-+
+

-+
+

----

-+
+

-+
+

-+
+

+
+
+

+
+
+

-+
+

5SM3 645-6
5SM3 646-6
5SM3 647-6

-+
+

-+
--

----

-+
--

-+
+

-+
+

+
+
+

+
+
+

-+
--

5SM3 648-6
5SM3 742-6
5SM3 744-6

-+
+

-+
+

----

-+
+

-+
+

-+
+

+
+
+

+
+
+

-+
+

5SM3 745-6
5SM3 746-6
5SM3 748-6

-+
--

+
--

----

-+
--

-+
--

+
+
--

+
+
+

+
+
+

-+

5SM3 . . .-8
5SM3 444-8
5SM3 446-8
5SM3 644-8

+
+
+

----

----

----

+
+
+

+
+
+

+
+
+

+
+
+

----

5SM3 645-8
5SM3 646-8
5SM3 647-8

-+
+

----

----

----

-+
--

+
+
--

+
+
+

+
+
+

----

5SM3 648-8
5SM3 745-8
5SM3 748-8
5SM3 846-8

---+

-----

-----

-----

-----

-+
---

+
+
+
+

+
+
+
+

-----

5SM3 . . .-6KK. .
5SM3 342-6KK01
5SM3 344-6KK01
5SM3 346-6KK01

+
+
+

----

----

----

----

+
+
--

+
+
+

+
+
+

----

5SM3 446-6KK01
5SM3 644-6KK01
5SM3 646-6KK01

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 647-6KK01
5SM3 342-6KK03
5SM3 344-6KK03

+
---

----

----

----

----

+
---

+
+
+

+
+
+

----

5SM3 342-6KK12
5SM3 344-6KK12
5SM3 346-6KK12

+
+
+

+
+
+

----

+
+
+

----

----

+
+
+

+
+
+

+
+
+

5SM3 347-6KK12
5SM3 644-6KK12
5SM3 646-6KK12

+
+
+

-+
+

----

-+
+

----

----

+
+
+

+
+
+

-+
+

5SM3 . . .-8KK. .
5SM3 646-8KK12

--

--

--

--

--

--

5SM3 . . .-6KL
5SM3 342-6KL
5SM3 344-6KL
5SM3 346-6KL

+
+
+

----

+
+
+

----

+
+
+

----

+
+
+

+
+
+

----

5SM3 347-6KL
5SM3 642-6KL
5SM3 644-6KL

+
+
+

----

+
+
+

----

+
+
+

----

+
+
+

+
+
+

----

5SM3 646-6KL
5SM3 647-6KL
5SM3 746-6KL

+
+
+

----

+
+
--

----

+
+
--

----

+
+
+

+
+
+

----

--

--

--

--

--

RCCBs, type A, 4-pole

5SM3 . . .-8KL
5SM3 646-8KL

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

Siemens LV 10.1 2011

20/15

20

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Belgium

France

Italy

Austria

Spain

Russia

China

Approvals

VDE

CEBEC

LCIE (NF)

IMQ

VE

AENOR

GOST

Fire Safety
Protection

CCC

5SM3 352-6
5SM3 354-6
5SM3 356-6

----

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 652-6
5SM3 654-6
5SM3 656-6

----

----

----

----

----

----

+
+
+

+
+
+

----

---

---

---

---

---

---

+
+

+
+

---

5SM3 . . .-4
5SM3 321-4
5SM3 322-4
5SM3 324-4

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 326-4
5SM3 342-4
5SM3 344-4

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 346-4
5SM3 347-4
5SM3 621-4

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 622-4
5SM3 624-4
5SM3 626-4

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 642-4
5SM3 644-4
5SM3 646-4

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 647-4
5SM3 746-4
5SM3 747-4

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 . . .-5
5SM3 646-5
5SM3 647-5
5SM3 746-5
5SM3 747-5

+
+
+
+

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

5SM3 . . .-4KK14
5SM3 321-4KK14
5SM3 322-4KK14
5SM3 324-4KK14

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 326-4KK14
5SM3 342-4KK14
5SM3 344-4KK14

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 346-4KK14
5SM3 347-4KK14
5SM3 621-4KK14

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 622-4KK14
5SM3 624-4KK14
5SM3 626-4KK14

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SM3 642-4KK14
5SM3 644-4KK14
5SM3 646-4KK14
5SM3 647-4KK14

+
+
+
+

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

5SM3 . . .-5KK14
5SM3 646-5KK14
5SM3 647-5KK14

+
+

---

---

---

---

---

+
+

+
+

---

5SU1 . . .-. AK8.


5SU1 374-7AK81
5SU1 374-7AK82
5SU1 674-7AK81

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SU1 674-7AK82
5SU1 374-8AK81
5SU1 674-8AK81

+
+
+

----

----

----

----

----

+
+
+

+
+
+

----

5SU1 . . .-. BK8.


5SU1 674-7BK82
5SU1 874-7BK82
5SU1 674-8BK81
5SU1 874-8BK81

+
+
+
+

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

RCCBs, type A, 500 V

RCCBs, type A, 50 ... 400 Hz


5SM3 342-6KK03
5SM3 344-6KK03

RCCBs, type B

RCCBs, type B+

RCBOs, type B

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

20

20/16

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Belgium

France

Italy

Austria

Spain

Russia

China

Approvals

VDE

CEBEC

LCIE (NF)

IMQ

VE

AENOR

GOST

Fire Safety
Protection

CCC

+
+

---

---

---

---

---

+
+

+
+

---

5SU1 . . .-. DK8.


5SU1 374-7DK81
5SU1 374-7DK82
5SU1 674-7DK81

----

----

----

----

----

----

+
+
+

+
+
+

----

5SU1 674-7DK82
5SU1 374-8DK81
5SU1 674-8DK81

----

----

----

----

----

----

+
+
+

+
+
+

----

5SU1 . . .-. EK8.


5SU1 674-8EK81
5SU1 674-7FK81
5SU1 674-7FK82

----

----

----

----

----

----

+
+
+

+
+
+

----

RCBOs, type B (continued)


5SU1 . . .-. CK8.
5SU1 674-7CK81
5SU1 674-7CK82

RCBOs, type B+

RCBOs, up to 40 A, type A
5SU1 324-6FA..
5SU1 324-7FA..
5SU1 .5.-6KK..

+
+
+

----

----

+
+
+

--+

----

+
+
+

+
+
+

--+

5SU1 .5.-7KK..
5SU1 353-7KL..
5SU1 354-7VK..

+
+
+

----

----

+
-+

+
+
--

----

+
+
+

+
+
+

+
---

5SU1 .24-6KK82
5SU1 .24-7KK82
5SU1 .44-6KK82
5SU1 .44-7KK82

+
+
---

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

5SU1 624-6WK82
5SU1 624-7WK82
5SU1 .44-6WK82
5SU1 .44-7WK82

+
+
---

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

RCBOs, 125 A, type A

RC units, up to 63 A, type A
5SM2 . . .-6
5SM2 121-6
5SM2 322-6
5SM2 325-6

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 332-6
5SM2 335-6
5SM2 342-6

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 345-6
5SM2 425-6
5SM2 435-6

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 445-6
5SM2 622-6
5SM2 625-6

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 632-6
5SM2 635-6
5SM2 642-6

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 645-6
5SM2 725-6
5SM2 735-6
5SM2 745-6

+
+
+
+

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

+
+
+
+

5SM2 . . .-6KK01
5SM2 322-6KK01
5SM2 325-6KK01
5SM2 332-6KK01

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 335-6KK01
5SM2 342-6KK01
5SM2 345-6KK01

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

Siemens LV 10.1 2011

20/17

20

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Belgium

France

Italy

Austria

Spain

Russia

China

Approvals

VDE

CEBEC

LCIE (NF)

IMQ

VE

AENOR

GOST

Fire Safety
Protection

CCC

RC units, up to 63 A, type A (continued)


5SM2 . . .-8
5SM2 622-8
5SM2 625-8
5SM2 635-8

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 645-8
5SM2 735-8
5SM2 745-8

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 822-8
5SM2 825-8
5SM2 832-8

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

5SM2 835-8
5SM2 842-8
5SM2 845-8

+
+
+

----

----

----

----

----

+
+
+

+
+
+

+
+
+

RC units, up to 100 A, type A


5SM2 . . .-6
5SM2 327-6
5SM2 347-6
5SM2 627-6
5SM2 647-6

+
-+
--

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

5SM2 . . .-8
5SM2 627-8
5SM2 647-8
5SM2 827-8
5SM2 847-8

+
-+
--

-----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

------

------

------

------

------

+
+
+
+
+

+
+
+
+
+

------

Additional components
5ST3 051
5SW3 300
5SW3 301
5SW3 302
5SW3 330

-+
+
+
+

Further certifications and approvals available on request.

+ Standard version approved.


-- Not yet submitted for approval.

Chapter 5 Fuse Systems


Application in

Germany,
Europe

Germany

Netherlands

Austria

Russia

Canada, USA

China

Approvals

VDE

GL

KEMA

VE

GOST

CCC

5SE2
5SE2 013-2A
5SE2 280
5SE2 300

+
+
+

----

----

----

+
+
+

----

----

----

5SE2 302
5SE2 304
5SE2 306

+
+
+

----

----

+
+
+

+
+
+

----

----

----

5SE2 31.
5SE2 32.
5SE2 332

+
+
+

----

----

+
+
--

+
+
+

----

----

----

5SE2 335
5SE2 340
5SE2 350
5SE2 363

+
+
+
+

-----

-----

+
-+
+

+
+
+
+

-----

-----

-----

5SG1
5SG1 .01
5SG1 .30
5SG1 . .2

+
+
--

----

----

----

+
+
+

----

----

----

5SG1 . .4
5SG1 . .5
5SG1 331

-+
--

----

----

----

+
+
+

----

----

----

5SG1 553
5SG1 590
5SG1 650

+
+
+

----

----

----

+
+
+

----

----

----

5SG1 653
5SG1 693
5SG1 731
5SG1 81.

+
+
+
--

-----

-----

-----

+
+
+
+

-----

-----

-----

NEOZED fuse systems

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

20

20/18

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Germany

Netherlands

Austria

Russia

Canada, USA

China

Approvals

VDE

GL

KEMA

VE

GOST

CCC

NEOZED fuse systems (continued)


5SG5
5SG5 . .0
5SG5 .01
5SG5 . .3

+
+
+

----

----

----

+
+
+

----

----

----

5SG5 .30
5SG5 555
5SG1 655
5SG1 695

+
-+
+

-----

-----

-----

+
+
+
+

-----

-----

-----

5SG7
5SG7 1. .
5SG7 133-8BA. .
5SG7 6. .

+
+
+

+
---

----

----

+
+
+

----

----

----

5SH4
5SH4 1. .
5SH4 316
5SH4 317
5SH4 362
5SH4 363

+
+
--+

------

------

------

+
+
+
+
+

------

------

------

5SH5
5SH5 0. .
5SH5 1. .
5SH5 2. .
5SH5 4. .

-+
---

-----

-----

-----

+
+
+
+

-----

-----

-----

5SA1 . .
5SA2 . .
5SB1 . .

-+
--

----

----

----

+
+
+

----

----

----

5SB2 . .
5SB3 . .
5SB4 010
5SB4 .1

+
-+
+

+
--+

+
--+

+
--+

+
+
+
+

-----

-----

-----

5SC1
5SC2
5SD6
5SD8

..
..
..
...

--+
--

-+
---

-----

-----

+
+
+
+

-----

-----

-----

5SF1
5SF1 005
5SF1 01
5SF1 012

+
+
+

+
---

+
---

----

+
+
+

----

----

----

5SF1 024
5SF1 060
5SF1 205
5SF1 214

+
-+
--

+
-+
+

+
----

-----

+
+
+
+

-----

-----

-----

5SF1 215
5SF1 224
5SF1 260
5SF1 401

-+
---

+
+
-+

+
----

-----

+
+
+
+

-----

-----

-----

5SF4
5SF4 . . .

--

--

--

--

--

--

--

5SF5
5SF5 066
5SF5 067
5SF5 068
5SF5 2. .

+
+
---

-----

-----

-----

+
+
+
+

-----

-----

-----

5SF6
5SF6 . . .

--

--

--

--

--

--

5SH1
5SH1 11
5SH1 12
5SH1 13

-+
+

-+
+

----

----

+
+
+

----

----

----

5SH1 141
5SH1 161
5SH1 170

----

+
---

----

----

+
+
+

----

----

----

5SH1 22
5SH1 221
5SH1 23
5SH1 231

-----

-----

-----

-----

+
+
+
+

-----

-----

-----

5SH2
5SH2 . .

--

--

--

--

--

--

--

--

5SH3
5SH3 . .
5SH3 703

---

---

---

---

+
--

---

---

---

DIAZED fuse systems

+ Standard version approved.

Further certifications and approvals available on request.

-- Not yet submitted for approval.

Siemens LV 10.1 2011

20/19

20

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Germany

Netherlands

Austria

Russia

Canada, USA

China

Approvals

VDE

GL

KEMA

VE

GOST

cUus

CCC

Cylindrical fuse systems


Cylindrical fuse links and cylindrical fuse holders
3NW6 . . .-1
3NW7 0. .
3NW7 1. .

----

----

----

----

+
+
+

----

-+
+

----

----

3NW7 2. .
3NW7 3. .
3NW8 . . .-1

----

----

----

----

+
+
+

----

----

----

----

Compact fuse holders for motor starter combinations


3NW7 03.-1
3NW7 53.-1HG
3NW7 903-1

----

----

----

----

----

+
---

-+
+

+
+
+

----

-----

-----

-----

-----

+
+
+
+

+
+
+
+

-----

+
+
+
+

-----

3NA3
3NA3 0. .
3NA3 1. .
3NA3 1. .-6

+
+
--

+
+
--

+
+
--

----

+
+
+

----

----

----

-+
+

3NA3 2. .
3NA3 250
3NA3 254

+
+
+

+
+
+

+
---

----

+
+
+

----

----

----

+
+
+

3NA3 2. .-6
3NA3 34.
3NA3 350

-+
--

-+
+

-+
--

----

+
+
+

----

----

----

+
+
+

3NA3 352
3NA3 354
3NA3 360

+
+
+

+
+
+

+
-+

----

+
+
+

----

----

----

+
+
+

3NA3 362
3NA3 365
3NA3 372

-+
+

----

-+
+

----

+
+
+

----

----

----

+
+
+

3NA3 4. .
3NA3 6. .
3NA3 8. .

+
+
+

--+

--+

----

+
+
+

----

----

----

+
+
+

3NA3 8. .-6
3NA3 8. .-7
3NA3 8. .-8

-+
--

-+
--

-+
--

----

+
+
+

----

----

----

+
---

3NA6 1
3NA6 10.
3NA6 110
3NA6 114

+
+
+

----

+
+
+

----

+
+
+

----

----

--+

----

3NA6 117
3NA6 12.
3NA6 13.

+
+
+

----

+
+
+

----

+
+
+

----

----

+
+
+

----

3NA6 14.
3NA6 1. .-4
3NA6 1. .-6

+
+
--

----

+
---

----

+
+
+

----

----

+
---

----

3NA6 2
3NA6 214
3NA6 220
3NA6 222

+
+
+

----

+
+
+

----

+
+
+

----

----

----

----

3NA6 224
3NA6 23.
3NA6 24.

+
+
+

----

+
+
+

----

+
+
+

----

----

+
+
+

----

3NA6 25.
3NA6 260
3NA6 22.-4

+
+
+

----

+
+
--

----

+
+
+

----

----

+
+
--

----

3NA6 23.-4
3NA6 24.-4
3NA6 250-4

+
+
--

----

----

----

+
+
+

----

----

----

----

3NA6 252-4
3NA6 254-4
3NA6 260-4
3NA6 2. .-6

+
-+
--

-----

-----

-----

+
+
+
+

-----

-----

-----

-----

Class CC fuse system


3NW1 . . .-0HG
3NW2 . . .-0HG
3NW3 . . .-0HG
3NW7 5.3-0HG

LV HRC Fuse Systems


LV HRC fuse links

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

20

20/20

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Germany

Netherlands

Austria

Russia

Canada, USA

China

Approvals

VDE

GL

KEMA

VE

GOST

CCC

LV HRC Fuse Systems


LV HRC fuse links (continued)
3NA6 8
3NA6 80.
3NA6 810
3NA6 812

+
+
+

----

+
+
+

----

+
+
+

----

--+

----

3NA6 814
3NA6 817
3NA6 82.

+
+
+

----

+
+
+

----

+
+
+

----

+
+
+

----

3NA6 830
3NA6 832
3NA6 836

+
+
+

----

+
+
+

----

+
+
+

----

+
+
--

----

3NA6 8. .-4
3NA6 8. .-4KK
3NA6 8. .-6
3NA6 8. .-7

+
+
-+

-----

---+

-----

+
+
+
+

-----

---+

-----

3NA7 1
3NA7 10.
3NA7 110
3NA7 114
3NA7 117

+
+
+
+

+
+
+
+

+
+
+
+

-----

+
+
+
+

-----

--+
+

-----

3NA7 12.
3NA7 13.
3NA7 14.
3NA7 1. .-6

+
+
+
--

+
+
+
--

+
+
+
--

-----

+
+
+
+

-----

+
+
+
--

-----

3NA7 2
3NA7 214
3NA7 220
3NA7 222

+
+
+

+
+
+

+
+
+

----

+
+
+

----

----

----

3NA7 224
3NA7 23.
3NA7 24.

+
+
+

+
+
+

+
+
+

----

+
+
+

----

+
+
+

----

3NA7 252
3NA7 260
3NA7 2. .-6

+
+
--

+
+
--

+
+
--

----

+
+
+

----

+
+
--

----

+
+
+
+

+
+
+
+

+
+
+
+

-----

+
+
+
+

-----

--+
+

-----

+
+
+

+
+
+

+
+
+

----

+
+
+

----

+
+
+

----

3NA7 832
3NA7 836
3NA7 8. .-6
3NA7 8. .-7

+
+
-+

+
+
-+

-----

-----

+
+
+
+

-----

+
----

-----

3ND1
3ND1-. . .

--

--

--

--

--

--

--

3ND2
3ND2-. . .

--

--

--

--

--

--

--

---

---

---

+
+

---

---

---

3NA7 8
3NA7 80.
3NA7 810
3NA7 812
3NA7 814
3NA7 817
3NA7 82.
3NA7 830

LV HRC signal detectors


3NX1 0. .
5TT3 170

---

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

Siemens LV 10.1 2011

20/21

20

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Germany

Netherlands

Austria

Russia

Canada, USA

China

Approvals

VDE

GL

KEMA

VE

GOST

CCC

LV HRC Fuse Systems


LV HRC fuse bases and accessories
3NH3
3NH3 030
3NH3 031
3NH3 032

----

+
+
+

+
+
+

----

+
+
+

----

+
---

----

----

3NH3 035
3NH3 036
3NH3 037

----

+
---

+
+
+

----

+
+
+

----

----

----

----

3NH3 038
3NH3 050
3NH3 051

----

-+
+

+
+
--

----

+
+
+

----

----

----

----

3NH3 052
3NH3 053
3NH3 1. .

----

+
+
+

--+

----

+
+
+

----

--+

----

----

3NH3 2. .
3NH3 3. .
3NH3 4. .
3NH3 5. .

-----

+
+
+
--

+
+
+
+

-----

+
+
+
+

-----

+
+
+
--

-----

-----

3NH4
3NH4 030
3NH4 031
3NH4 032

----

+
+
+

+
+
+

----

+
+
+

----

+
---

----

----

3NH4 035
3NH4 037
3NH4 045
3NH4 230

-----

+
--+

+
+
+
+

-----

+
+
+
+

-----

---+

-----

-----

3NH7
3NH7 . . .

--

--

--

--

--

--

--

--

SITOR semiconductor fuses


SITOR LV HRC design
3NC
3NC2 4. .
3NC3 2. .-1
3NC3 2. .-6

----

----

----

----

+
+
+

-+
+

----

----

----

3NC3 3. .-1
3NC3 3. .-6
3NC3 4. .-1

----

----

----

----

+
+
+

+
+
--

----

----

----

3NC3 4. .-6
3NC5 . . .
3NC7 . . .
3NC8 4. .

-----

-----

-----

-----

+
+
+
+

-----

-----

-----

-----

3NE1
3NE1 0. .-0
3NE1 0. .-2
3NE1 224-0

----

----

----

----

+
+
+

+
+
--

----

----

+
+
+

3NE1 225-0
3NE1 230-0
3NE1 2. .-2

----

----

----

----

+
+
+

+
+
+

----

----

+
+
+

3NE1 2. .-3
3NE1 3. .-0
3NE1 331-2

----

----

----

----

+
+
+

+
+
+

----

----

+
+
+

3NE1 332-2
3NE1 333-2
3NE1 334-2

----

----

----

----

+
+
+

-+
+

----

----

+
+
+

3NE1 331-3
3NE1 332-3
3NE1 333-3

----

----

----

----

+
+
+

+
-+

----

----

+
+
+

3NE1 334-3
3NE1 435-0
3NE1 436-0

----

----

----

----

+
+
+

+
+
+

----

----

+
---

3NE1 437-0
3NE1 438-0
3NE1 4. .-1

----

----

----

----

+
+
+

--+

----

----

--+

3NE1 4. .-2
3NE1 4. .-3
3NE1 8. .-0

----

----

----

----

+
+
+

+
+
+

----

----

+
+
+

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

20

20/22

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Standards and approvals
Application in

Germany,
Europe

Germany

Netherlands

Austria

Russia

Canada, USA

China

Approvals

VDE

GL

KEMA

VE

GOST

CCC

SITOR semiconductor fuses


SITOR LV HRC design (continued)
3NE3
3NE3 2. .
3NE3 3. .
3NE3 4. .-0C

----

----

----

----

+
+
+

+
+
--

----

+
+
--

3NE3 6. .-0C
3NE3 6. .-1C
3NE3 6. .-6

----

----

----

----

+
+
+

----

----

----

3NE4
3NE4 1. .
3NE4 1. .-5
3NE4 337

----

----

----

----

+
+
+

+
---

----

+
---

3NE4 3. .-0B
3NE4 3. .-6
3NE4 3. .-6B

----

----

----

----

+
+
+

----

----

----

3NE5
3NE5 4. .-0C
3NE5 6. .-0C

---

---

---

---

+
+

---

---

---

3NE6
3NE6 . . .

--

--

--

--

--

--

--

3NE7
3NE7 4. .-0C
3NE7 6. .-0C
3NE7 6. .-1C

----

----

----

----

+
+
+

+
+
+

----

----

3NE8
3NE8 0. .
3NE8 7. .

---

---

---

---

+
+

-+

-+

+
--

3NE9
3NE9 . . .

--

--

--

--

--

--

--

SITOR, cylindrical fuse design


3NC1
3NC1 003
3NC1 006
3NC1 008

----

----

----

----

+
+
+

-+
+

-+
+

----

3NC1 01.
3NC1 02.
3NC1 032

----

----

----

----

+
+
+

+
+
+

+
+
+

----

3NC1 038-.
3NC1 09.
3NC1 40.

----

----

----

----

+
+
+

-+
+

+
+
+

----

3NC1 41.
3NC1 42.
3NC1 43.
3NC1 440

-----

-----

-----

-----

+
+
+
+

+
+
+
+

+
+
+
+

-----

3NC1 450
3NC1 49.
3NC1 451-1
3NC1 4. .-5

-----

-----

-----

-----

+
+
+
+

-+
-+

+
+
-+

-----

3NC2
3NC2 200
3NC2 22.
3NC2 232

----

----

----

----

+
+
+

+
+
+

+
+
+

----

3NC2 240
3NC2 250
3NC2 263

----

----

----

----

+
+
+

+
+
+

+
+
+

----

3NC2 280
3NC2 29.
3NC2 258-1
3NC2 2. .-5

-----

-----

-----

-----

+
+
+
+

+
+
-+

+
+
---

-----

---

---

+
+

---

---

---

NEOZED and DIAZED design, SILIZED


5SD4 . . .
5SE1 . . .

---

---

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

Siemens LV 10.1 2011

20/23

20

Siemens AG 2011

Appendix
Standards and approvals
Chapter 6 Overvoltage Protection Devices
Application in

Germany, Europe

Netherlands

Russia

Approvals

VDE

KEMA

GOST

--

--

--

--

-----

+
----

+
+
+
+

----

+
-+

+
+
+

5SD7 418-0
5SD7 418-1
5SD7 428-.
5SD7 437-., 5SD7 438-.

-----

+
-+
+

+
+
+
+

5SD7 448-1
5SD7 468-1
5SD7 488-.
5SD7 498-.

-----

+
-+
--

+
+
+
+

--

--

Lightning arresters, type 1


5SD7 41.-1

Combination surge arresters, type 1 and type 2


5SD7 44.-1

Surge arresters, type 2


5SD7 42.-.
5SD7 46.-.
5SD7 47.-.
5SD7 48.-.

Surge arresters, type 3


5SD7 432-1, 5SD7 432-2
5SD7 432-3, 5SD7 432-4
5SD7 434-1

Accessories for surge arresters

Link rails
5SD7 490-.

Surge arresters for measuring and control technology


5SD7 5. .-.

--

Further certifications and approvals available on request.

+ Standard version approved.


-- Not yet submitted for approval.

Chapter 7 Switch Disconnectors


Approvals

Marine classifications

Canada1)2)

USA1)

China

Germany

United Kingdom

Norway

Poland

s
u
cUus
U
3LD main control and EMERGENCY-STOP switches up to 250 A

CCC

GL

LRS

DNV

PRS

3LD20
3LD21
3LD22
3LD25

+
+
+
+

-----

+
+
+
+

-----

+
+
+
+

+3)
+3)
+3)
+3)

+3)
+3)
+3)
+3)

+3)
+3)
+3)
+3)

+3)
+3)
+3)
+3)

3LD27
3LD28
3LD23
3LD24

+
+
+
+

-----

+
+
+
+

-----

+
+
+4)
+4)

+3)
+3)
+3)
+3)

+3)
+3)
+3)
+3)

+3)
+3)
+3)
+3)

+3)
+3)
+3)
+3)

Application in
Approvals

+ Standard version approved.

2)

cu and cU approvals are available in accordance with US approval.

-- Not yet submitted for approval.

3)

Not all versions are approved. Request required.

Further certifications and approvals available on request.

4)

Available soon.

1)

For guide numbers and file numbers for the approvals, visit our website at
www.siemens.com/lowvoltage/support.

Application in

Germany, Europe

France

Russia

USA, Canada

China

Approvals

VDE

LCIE (NF)

GOST

CCC

5TE1 switch disconnectors up to 200 A


5TE1 2.0
5TE1 310
5TE1 315
5TE1 320

-----

+
+
+
+

+
+
+
+

---+

-----

5TE1 325
5TE1 330
5TE1 335
5TE1 340

-----

+
+
+
+

+
+
+
+

-+
-+

-----

5TE1 345
5TE1 410
5TE1 415
5TE1 420

-----

+
+
+
+

+
+
+
+

---+

-----

5TE1 425
5TE1 430
5TE1 435

----

+
+
+

+
+
+

-+
--

----

5TE1 440
5TE1 445
5TE1 6.0

----

+
+
+

+
+
+

+
---

----

+ Standard version approved.


-- Not yet submitted for approval.

20

20/24

Siemens LV 10.1 2011

Further certifications and approvals available on request.

Siemens AG 2011

Appendix
Standards and approvals
Approvals
Application in

Marine classifications
USA1)

Canada

China

Germany France

United
CIS
Kingdom

Norway

Poland

s
u
cUus
SENTRON 3KA, 3KE switch disconnectors up to 1000 A

CCC

GL

BV

LRS

RMRS

DNV

PRS

3KA50
3KA51
3KA52 30, 3KA53 30, 3KA55 30

--+2)3)

----

--+2)3)

----

----

+
---

+
+
+

+3)
---

+3)
---

----

+
+
+

3KA57
3KA57 30
3KA58
3KA58 30

-+2)3)
-+2)3)

-----

-+2)3)
-+2)3)

-----

+
+
+
+

+3)
+3)
---

+
+
+
+

-----

-----

-----

+
+
+
+

3KE42
3KE43
3KE44
3KE45

-----

-----

-----

-----

---+3)

-----

+
+
+
+

-----

-----

-----

+
+
+
+

Approvals

SENTRON 3KL switch disconnectors with fuses up to 800 A


3KL50
3KL52
3KL52 30
3KL52 40

-----

-----

-----

--+2)3)
--

+4)
-+4)
+4)

+3)
+3)
+3)
+3)

+
+
+
+

+3)
+3)
+3)
+3)

-+3)
---

-----

+
+
+
+

3KL53 30
3KL53 40
3KL55
3KL55 30

-----

-----

-----

+2)3)
+2)3)
-+2)3)

+4)
+4)
-+4)

-----

+
+
+
+

--+3)
--

-----

-----

+
+
+
+

3KL55 40
3KL57
3KL57 30

----

----

----

--+2)3)

+4)
-+4)

----

+
+
+

-+3)
--

----

----

+
+
+

3KL57 40
3KL61 30
3KL62 30-1AB02

----

----

----

-+2)3)
+2)3)

+4)
+4)
+4)

----

+
+
+

----

----

----

+
+
+

SENTRON 3KM Switch Disconnectors with Fuses and Isolating Plug Connector up to 400 A
3KM50
3KM52
3KM53

----

----

----

----

----

+3)
+3)
--

+
---

+3)
+3)
--

+3)
---

----

+
+
+

3KM55
3KM57

---

---

---

---

---

---

---

+3)
+3)

---

---

+
+

SENTRON 3NJ62 in-line switch disconnectors with fuses up to 630 A


3NJ62

--

--

--

--

+4)

--

--

--

--

+4)

--

--

+4)

--

+4)

--

+4)

--

--

--

--

--

--

--

SENTRON 3NP1 fuse switch disconnectors up to 630 A


3NP1

--

--

SENTRON 3NP5 fuse switch disconnectors up to 630 A


3NP5

--

--

--

SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A


3NJ41 03
3NJ41 21
3NJ41 23
3NJ41 31

-----

-----

-----

-----

+3)
+3)
+3)
+3)

-----

-----

-----

-----

-----

-----

3NJ41 33
3NJ41 41
3NJ41 43

----

----

----

----

+3)
+3)
+3)

----

----

----

----

----

----

3NJ50 13

--

--

--

--

+3)

--

--

--

--

--

--

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

1)

For guide numbers and file numbers for the approvals, visit our website at
www.siemens.com/lowvoltage/support.

2)

Approved rated data on request.

3)

Not all versions are approved. Request required.

4)

Available soon.

Siemens LV 10.1 2011

20/25

20

Siemens AG 2011

Appendix
Standards and approvals
Chapter 8 Controls
Application in

Germany, Europe

Netherlands

Russia

USA, Canada

China

Approvals

VDE

KEMA

GOST

CCC

5TE8 101
5TE8 101-3
5TE8 102

+
-+

----

+
+
+

----

+
+
+

5TE8 103
5TE8 105
5TE8 108

+
-+

----

+
+
+

----

+
+
--

5TE8 14.
5TE8 15.
5TE8 16.

+
+
+

----

+
+
+

----

-+
--

--

--

Control switches

Pushbuttons
5TE4 8. .

Further certifications and approvals available on request.

+ Standard version approved.


-- Not yet submitted for approval.

Application in

Germany, Europe

France

Russia

USA, Canada

Approvals

VDE

LCIE (NF)

GOST

cUus

China
CCC

+
+
+
-+

------

+
+
+
+
+

------

------

------

5TE8 .11
5TE8 .12
5TE8 .13

+
+
+

----

+
+
+

----

----

+
+
+

5TE8 .14
5TE8 .15
5TE8 118

+
-+

----

+
+
+

----

----

+
+
--

5TE8 218
5TE8 52.
5TE8 533
5TE8 72.

-+
+
+

-----

+
+
+
+

-----

-----

-+
---

--

--

--

--

--

--

--

--

--

--

--

------

+
-+
+
+

+
+
+
+
+

------

------

------

--

--

--

--

--

+
+
+
+
+

------

+
+
+
+
+

-+
+
+
--

+
-----

------

7LF5 300-1
7LF5 300-5
7LF5 300-6

+
+
+

----

+
+
+

+
+
+

----

----

7LF5 300-7
7LF5 301-.
7LF5 305-0

+
+
+

----

+
+
+

-+
+

----

----

--

--

--

--

--

--

--

--

--

Indicator light
5TE5 800
5TE5 801
5TE5 802
5TE5 803
5TE5 8004

ON/OFF switches

Remote control switches


5TT4 1. .

Switching relays
5TT4 2. .

Insta contactors (DC technology)


5TT5 7. .

--

Insta contactors (AC technology)


5TT5 80.
5TT5 820-0
5TT5 83.
5TT5 84.
5TT5 85.

Soft-starting devices
5TT3 4. .

Timers
Digital time switches
7LF4 40.
7LF4 41.
7LF4 42.
7LF4 43.
7LF4 44.

Mechanical time switches

Timers for buildings


7LF6 1. .

Timers for industrial applications


5TT3 18.

--

+ Standard version approved.


-- Not yet submitted for approval.

Further certifications and approvals available on request.

20

20/26

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Standards and approvals
Chapter 9 Transformers, Bells and Socket Outlets
Application in

Germany, Europe

Italy

Russia

USA, Canada

Approvals

VDE

IMQ

GOST

cUus

-+
+
+

+
+
+
+

+
+
+
+

-----

----

+
+
+

+
+
+

----

----

+
+
--

+
+
+

----

--

--

--

5TE6 800
5TE6 801
5TE6 802

+
+
--

----

+
+
+

----

5TE6 803
5TE6 804
5TE6 810

--+

----

+
+
+

-+
--

Bell transformers
4AC3 006
4AC3 008
4AC3 016
4AC3 1. .

Transformers for permanent loads


4AC3 4. .
4AC3 5. .
4AC3 6. .

Power supply units


4AC2 400
4AC2 401
4AC2 402

Bells and buzzers


7LQ2 . . .

REG socket outlets

Further certifications and approvals available on request.

+ Standard version approved.


-- Not yet submitted for approval.

Chapter 10 Busbar Systems


Application in

Canada

Approvals

cUus

USA

--

--

40 mm busbar systems
8US

60 mm busbar systems
8US

Further certifications and approvals available on request.

More information
You can find more information about standards and approvals at
www.siemens.com/lowvoltage/support

Siemens LV 10.1 2011

20/27

20

Siemens AG 2011

Appendix
Siemens contacts

Contact partner at Siemens Industry


At Siemens Industry, more than 85 000 people are resolutely
pursuing the same goal: long-term improvement of your competitive ability. We are committed to this goal. Thanks to our commitment, we continue to set new standards. In all industries worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
Product group,
Country,
City,
Service.

20

20/28

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Solution partners

Solution partners - Automation, power distribution and PLM


Solution Partner Finder
The Siemens Solution Partner Program helps you to find the optimum partner for your specific requirements. Support is provided by the Solution Partner Finder, a comprehensive online database that showcases the profiles of all our solution partners.
You can convince yourself of the competence of the respective
Solution Partner by means of the references provided.
The following search criteria are possible:
Country
Technology
Sector
Company
Zip code
Once you have located a partner, you are only one small step
from contacting them.
You can locate the Solution Partner Finder as follows:
www.siemens.com/automation/partnerfinder
Additional information on the Siemens Solution Partner Program
is available online at:
The products and systems from Siemens Industry Automation
and Drive Technologies offer the ideal platform for all automation
applications.

www.siemens.com/automation/solutionpartner

Under the name Siemens Solution Partner, selected system integrators operate around the world as uniformly qualified solution
providers for the portfolio of Siemens automation, power distribution and product lifecycle management products. Day after
day, they utilize their qualified product and system know-how as
well as their excellent industry expertise to your advantage
for all requirements.
The Solution Partner emblem is a guarantee of quality.
The basis for this is to be found in four defined quality features:
Solution quality:
A good result in every case based on proven solution knowhow.
Expert quality:
Certified technical competence guarantees maximum efficiency.
Project quality:
Straight to the goal with proven project experience.
Product range quality:
Comprehensive portfolio for state-of-the-art solutions from a
single source.

Siemens LV 10.1 2011

20/29

20

Siemens AG 2011

Appendix
Online Services
Information and ordering options available
on the Internet and DVD

Siemens Building Technologies on the web


The Siemens Division Building Technologies offers the full range
of products and solutions for secure and energy-efficient buildings and infrastructures from building automation and heating,
ventilation and air-conditioning systems (HLK) to fire protection,
security, low-voltage power distribution and electrical installation
technology.
Extensive information about all products, systems and services
and support services is available in a compact and clear format
on the Internet at:
www.siemens.com/buildingtechnologies

Product selection with the interactive catalog CA 01


Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry
product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found in the
Internet under:
www.siemens.com/automation/ca01
or on DVD.

Easy Shopping with the Industry Mall


The Industry Mall is the virtual department store of Siemens AG
on the Internet. Here you have access to a huge range of products clearly and informatively presented in electronic catalogs.
Data transfer via EDIFACT allows the whole procedure, from selection over ordering through to order tracking, to be carried out
online over the Internet.
A range of functions offer comprehensive support.
These include powerful search functions that make it easy to find
the required products, which can then be immediately checked
for availability. Customer-specific discounting and compilation of
tenders are possible online, as is checking the status of your order (Tracking & Tracing).
You can find the Industry Mall on the Internet at:
www.siemens.com/industrymall

20

20/30

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Service & Support
The unmatched complete service
for the entire life cycle

For machine constructors, solution providers and plant operators: The service offering from Siemens Industry, Automation and
Drive Technologies includes comprehensive services for a wide
range of different users in all sectors of the manufacturing and
process industry
To accompany our products and systems, we offer integrated
and structured services that provide valuable support in every
phase of the life cycle of your machine or plant - from planning
and implementation through commissioning as far as maintenance and modernization.

Online Support

Our Service & Support accompanies you worldwide in all matters concerning automation and drives from Siemens. We provide direct on-site support in more than 100 countries through all
phases of the life cycle of your machines and plants.
You have an experienced team of specialists at your side to provide active support and bundled know-how. Regular training
courses and intensive contact among our employees - even
across continents - ensure reliable service in the most diverse
areas.

Technical Consulting
The comprehensive online information platform supports you in
all aspects of our Service & Support at any time and from any location in the world.

Support in planning and designing your project: From detailed


actual-state analysis, definition
of the goal and consulting on
product and system questions
right through to the creation of
the automation solution.

www.siemens.com/lowvoltage/
support

Technical Support

Training
Expert advice on technical
questions with a wide range of
demand-optimized services for
all our products and systems.

Extend your competitive edge through practical know-how


directly from the manufacturer.
www.siemens.com/sitrain

www.siemens.com/lowvoltage/
technical-support

Contact information is available in the Internet at:


www.siemens.com/automation/partner
Siemens LV 10.1 2011

20/31

20

Siemens AG 2011

Appendix
Service & Support
The unmatched complete service
for the entire life cycle

Engineering Support

Modernization
Support during project engineering and development with
services fine-tuned to your requirements, from configuration
through to implementation of an
automation project.

Field Service

You can also rely on our support


when it comes to modernization
- with comprehensive services
from the planning phase all the
way to commissioning.

Service programs
Our Field Service offers you services for commissioning and
maintenance - to ensure that
your machines and plants are
always available.

Our service programs are selected service packages for an


automation and drives system or
product group. The individual
services are coordinated with
each over to ensure smooth
coverage of the entire life cycle
and support optimum use of
your products and systems.
The services of a service program can be flexibly adapted at
any time and used separately.

Spare parts
In every sector worldwide,
plants and systems are required
to operate with constantly increasing reliability. We will provide you with the support you
need to prevent a standstill from
occurring in the first place: with
a worldwide network and optimum logistics chains.

Examples of service programs:


Service contracts
7 Plant IT Security Services
7 Life Cycle Services for Drive Engineering
7 SIMATIC PCS 7 Life Cycle Services
7 SINUMERIK Manufacturing Excellence
7 SIMATIC Remote Support Servicess
7

Advantages at a glance:
Reduced downtimes for increased productivity
7 Optimized maintenance costs due to a tailored scope of services
7 Costs that can be calculated and therefore planned
7 Service reliability due to guaranteed response times and
spare part delivery times
7 Customer service personnel will be supported and relieved of
additional tasks
7 Comprehensive service from a single source, fewer interfaces
and greater expertise
7

Repairs
Downtimes cause problems in
the plant as well as unnecessary
costs. We can help you to reduce both to a minimum - with
our worldwide repair facilities.

Optimization
During the service life of machines and plants, there is often
a great potential for increasing
productivity or reducing costs.
To help you achieve this potential, we are offering a complete
range of optimization services.

Contact information is available in the Internet at:


www.siemens.com/automation/partner

20

20/32

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Comprehensive support from A to Z

Overview
Product information
Website

Fast and targeted information about low-voltage


power distribution:

In all issues for more efficiency - comprehensive support and access at any time to tried and tested tools, quickly and easily via
the Internet.

www.siemens.com/lowvoltage
Newsletter

Always up to date about our forward-looking products and systems:


www.siemens.com/lowvoltage/newsletter

Product information/product & system selection


Information and
download center

Current catalogs, customer magazines, brochures,


demo software and promotion packages:
www.siemens.com/lowvoltage/infomaterial

Industry Mall

Comprehensive information and order platform for


the Siemens Industry Basket:
www.siemens.com/industrymall

Product- & System-Engineering


SIMARIS
Software tools

Support in planning and configuration the electrical


power distribution:
www.siemens.com/simaris

Engineering software ALPHA


SELECT

Simple and fast configuration for distribution boards


and meter cabinets with products from the Siemens
Industry Basket:
www.siemens.com/alpha-select

Product documentation
Service & support
portal

Comprehensive technical information - from planning


to configuration and operation:
www.siemens.com/lowvoltage/support

CAx Data

Collation of commercial and technical master product data:


www.siemens.com/cax

Image database

Collection of product photographs and graphics,


such as dimensional drawings and internal circuit
diagrams:
www.siemens.de/lowvoltage/bilddb

Product training
SITRAIN Portal

Comprehensive training program about our products, systems and engineering tools:
www.siemens.com/lowvoltage/training

Product hotline
Technical support

Support in all technical queries about our products:


E-mail: support.automation@siemens.com
www.siemens.com/lowvoltage/technical-support

Siemens LV 10.1 2011

20/33

20

Siemens AG 2011

Appendix
Software licenses

Overview
Software types
Software requiring a license is categorized into types.
The following software types have been defined:
Engineering software
Runtime software

Factory license
With the Factory License the user has the right to install and use
the software at one permanent establishment only. The permanent establishment is defined by one address only.The number
of hardware devices on which the software may be installed results from the order data or the Certificate of License (CoL).

Engineering software
This includes all software products for creating (engineering)
user software, e.g. for configuring, programming, parameterizing, testing, commissioning or servicing.
Data generated with engineering software and executable
programs can be duplicated for your own use or for use by thirdparties free-of-charge.

Certificate of license
The Certificate of License (CoL) is the licensee's proof that the
use of the software has been licensed by Siemens. A CoL is
required for every type of use and must be kept in a safe place.

Runtime software
This includes all software products required for plant/machine
operation, e.g. operating system, basic system, system expansions, drivers, etc.
The duplication of the runtime software and executable programs created with the runtime software for your own use or for
use by third-parties is subject to a charge.
You can find information about license fees according to use in
the ordering data (e.g. in the catalog). Examples of categories of
use include per CPU, per installation, per channel, per instance,
per axis, per control loop, per variable, etc.
Information about extended rights of use for parameterization/configuration tools supplied as integral components of the
scope of delivery can be found in the readme file supplied with
the relevant product(s).
License types
Siemens Industry Automation & Drive Technologies offers various types of software license:
Floating license
Single license
Rental license
Trial license
Floating license
The software may be installed for internal use on any number of
devices by the licensee. Only the concurrent user is licensed.
The concurrent user is the person using the program. Use begins when the software is started.
A license is required for each concurrent user.
Single license
Unlike the floating license, a single license permits only one
installation of the software.
The type of use licensed is specified in the ordering data and
in the Certificate of License (CoL). Types of use include for
example per device, per axis, per channel, etc.
One single license is required for each type of use defined.
Rental license
A rental license supports the "sporadic use" of engineering
software. Once the license key has been installed, the software
can be used for a specific number of hours (the operating hours
do not have to be consecutive).
One license is required for each installation of the software.
Trial license
A trial license supports "short-term use" of the software in a nonproductive context, e.g. for testing and evaluation purposes.
It can be transferred to another license.

20

20/34

Siemens LV 10.1 2011

Downgrading
The licensee is permitted to use the software or an earlier version/release of the software, provided that the licensee owns
such a version/release and its use is technically feasible.
Delivery versions
Software is constantly being updated.
The following delivery versions
PowerPack
Upgrade
can be used to access updates.
Existing bug fixes are supplied with the ServicePack version.
PowerPack
PowerPacks can be used to upgrade to more powerful software.
The licensee receives a new license agreement and CoL
(Certificate of License) with the PowerPack. This CoL, together
with the CoL for the original product, proves that the new software is licensed.
A separate PowerPack must be purchased for each original
license of the software to be replaced.
Upgrade
An upgrade permits the use of a new version of the software on
the condition that a license for a previous version of the product
is already held.
The licensee receives a new license agreement and CoL with
the upgrade. This CoL, together with the CoL for the previous
product, proves that the new version is licensed.
A separate upgrade must be purchased for each original license
of the software to be upgraded.
ServicePack
ServicePacks are used to debug existing products.
ServicePacks may be duplicated for use as prescribed according to the number of existing original licenses.
License key
Siemens Industry Automation & Drive Technologies supplies
software products with and without license keys.
The license key serves as an electronic license stamp and
is also the "switch" for activating the software (floating license,
rental license, etc.).
The complete installation of software products requiring license
keys includes the program to be licensed (the software) and the
license key (which represents the license).
Detailed explanations concerning license conditions can be found in the
Terms and Conditions of Siemens AG or under
www.siemens.com/industrymall
(Industry Mall Online-Help System)

Siemens AG 2011

Appendix
Subject index

Overview
Numerics

4. contact (N conductor)
For 3LD 7/22, 7/24, 7/25

Base load resistors


For electronic devices 12/35
Bases
For 8US 10/12
Basic element
For surge arresters 6/17
Basic switch version
For 3KA/3KE 7/34
Bell transformers 9/4
Bells 9/9
Bi-metal ammeters
For 3NJ62 7/83
Bi-metal measuring instruments
For 3NJ62 7/83
Blanking covers
For 3NJ4/3NJ5 7/123
For 3NJ62 7/88
For 8US 10/13
Block library 3WL/3VL for SIMATIC PCS 7 13/14
Box terminal assembly kit
For 3NJ4/3NJ5 7/125
Box terminals
3NP1 version 7/92, 7/93, 7/97
For 3NJ4/3NJ5 7/125
Breaker blocking covers
For miniature circuit breakers 3/57
Busbar adapter systems 2/89
Busbar adapters
3NP5 7/117
For main miniature circuit breakers (SHU) 3/57
For MINIZED switch disconnectors 5/11
Busbar connection pieces
For 8US 10/12, 10/13, 10/24, 10/25
Busbar covers
For 3NJ62 7/88
Busbar device adapters
For 8US 10/16
Busbar supports 10/10
For 3NJ4/3NJ5 7/124
For 8US 10/13
Busbar terminals
For 3NJ4/3NJ5 7/124
Busbars 5/29 ... 5/32
Acc. to UL 489 3/53
Acc. to UL 508 3/45, 5/32
For residual current protective devices 4/24, 4/25
Standard 3/28, 3/39 ... 3/42
Bus-mounting bases
DIAZED 5/15
Buzzers 9/9

A
Accessories
For PAC3200 power monitoring devices 11/26, 11/27, 11/28
Adapter for screw fixing
For 3NJ4/3NJ5 7/124
Adapter sleeve fitters
For DIAZED fuse bases 5/16
For NEOZED 5/11
Adapter sleeves
For DIAZED fuse bases 5/16
For NEOZED fuse bases 5/11
Adapters with busbar terminal
For 3NJ4/3NJ5 7/124
Aerials
For GSM alarm modules 12/30
Air circuit breakers/non-automatic air circuit breakers 1/1 ... 1/54
ALPHA SELECT 13/7
Ammeter selector switches 11/40
Ammeters
Analog 11/32
Digital 11/34
For 3NJ62 7/73, 7/83, 7/85, 7/87
Analog ammeter 11/32
Analog voltmeters 11/32
Arc chute
For 3KA/3KE 7/41, 7/42
For 3NP5 7/114
Arcing contacts
For 3KA/3KE 7/41, 7/42
Assembly kits
For SR60 distribution board components 10/9
Assembly kits for flush mounting
For 3NP 7/117
Assembly tools
For 3LD 7/21, 7/22, 7/24
Auxiliary conductor connections
For 3NP1 7/98, 7/100, 7/102, 7/104, 7/105
Auxiliary releases
For circuit breakers 1/23, 1/40, 2/57, 2/59 ... 2/60
Auxiliary switch mounting kit 7/126
For 3NJ4/3NJ5 7/126
Auxiliary switches
For 3KA/3KE 7/40, 7/42
For 3KL 7/49, 7/50, 7/56
For 3LD 7/21, 7/22, 7/24, 7/25
For 3NJ62 7/73, 7/82, 7/84, 7/86
For 3NP1 7/99, 7/101, 7/103, 7/104, 7/105
For 3NP5 7/114
For circuit breakers 1/23, 1/40, 2/57, 2/59 ... 2/61
Auxiliary switches (AS)
For Control Switches 8/7
For cylindrical fuse holders 5/21
For DC isolators 8/20
For Insta contactors 8/32, 8/35, 8/36
For miniature circuit breakers 3/31, 3/52
For MINIZED switch disconnectors 5/8
For ON/OFF switches 8/18
For remote control switches 8/27
For residual current protective devices 4/14
For switch disconnectors 7/28

C
Cable connection cover
For 3NP1 7/99, 7/101, 7/103, 7/104, 7/105
Cap sets
For Control Switches 8/7
For light indicators 8/14
For pushbuttons 8/11
Caps
For DIAZED fuse bases 5/16
Centralized fault signaling unit 12/31
Changeover switches
For 3KA/3KE 7/41, 7/42
Changeover switches with interruption
For 3KA/3KE 7/41
Changeover switches without interruption
For 3KA/3KE 7/42
Circuit breaker terminals 3/59

Siemens LV 10.1 2011

20/35

20

Siemens AG 2011

Appendix
Subject index
Circuit breakers
Air 1/1 ... 1/54
Auxiliary releases for 1/23, 1/40, 2/57, 2/59 ... 2/60
Auxiliary switches 1/23, 1/40
Auxiliary switches for 2/57, 2/59 ... 2/61
Communication-capable 1/26, 1/43, 2/12 ... 2/29, 2/40 ... 2/51, 2/98
Connection methods for 1/27 ... 1/28, 1/45 ... 1/46
Conversion sets 1/47
Fixed mounting 1/7 ... 1/10, 1/15 ... 1/18, 1/50, 2/10 ... 2/54
Generator protection 2/46 ... 2/51
Guide frames for 1/30 ... 1/33, 1/53 ... 1/54
Interlocks for 2/83 ... 2/88
Molded-case 2/1 ... 2/98
Non-automatic molded case circuit breakers 2/30 ... 2/31, 2/52 ... 2/53
Operating mechanisms for 1/23, 1/25, 1/40, 2/55, 2/56, 2/62 ... 2/69
Plug-in version 2/70 ... 2/75
RCD modules 2/76
Shunt releases 1/23, 1/40
Shunt releases for 2/57, 2/59 ... 2/60
System protection 2/10 ... 2/25, 2/34 ... 2/51
Undervoltage releases 1/23, 1/40
Undervoltage releases for 2/57, 2/59 ... 2/60
With electronic release 1/7 ... 1/22, 1/34, 2/10 ... 2/29, 2/34 ... 2/51
Withdrawable bridging units 1/48
Withdrawable grounding units 1/48
Withdrawable short-circuits 1/48
Withdrawable version 1/11 ... 1/14, 1/19 ... 1/22, 1/51 ... 1/52, 2/70 ... 2/75
Clamp terminals
For 3NP5 7/117
Combination surge arresters 6/6
Communication modules for E-counters 11/12
Communication-capable circuit breakers 1/26, 1/43, 2/12 ... 2/29,
2/40 ... 2/51, 2/98
Compensator 8/27
Complete version
For 3KA/3KE 7/34
Completely compartmentalized
3NP5 version 7/108, 7/109, 7/110, 7/111, 7/112, 7/113
Configuration 13/7
Configuring, Visualizing and Controlling with SIMATIC 13/9 ... 13/15
Connecting terminal plates
For 8US 10/14
Connecting wedges
For 8US 10/25
Connection assembly kits
For 3NJ4/3NJ5 7/125
Connection holders
For 8US 10/25
Connection methods
For circuit breakers 1/27 ... 1/28, 1/45 ... 1/46
For fixed-mounted circuit breakers 2/77 ... 2/82
Connection modules 10/23
For 3NJ62 7/88
For 3NP1 7/100
Contact extensions
For 3NJ62 7/82, 7/84, 7/86
Control pushbuttons 8/10
Control switches 8/6
Control switches 8/6
Group switches 8/6
Two-way switches 8/6
Conversion sets
Fixed-mounted circuit breakers to withdrawable circuit breakers 1/47
Coupling drivers
For door-coupling rotary operating mechanisms 7/62
Cover IP20
For 3KL 7/48, 7/49
Cover profiles
For 8US 10/11, 10/13
Cover rings 5/17
Cover support
For 3NP1 7/99, 7/101, 7/103, 7/104, 7/105
Covers 1/26, 1/35, 1/41, 3/35, 4/25
For DIAZED fuse bases 5/16
For DIAZED SR60 bus-mounting bases 10/31
For LV HRC fuse bases 5/48
For miniature circuit breakers 3/35
For NEOZED fuse bases 5/10
For NEOZED SR60 bus-mounting bases 10/30
For 3NJ4/3NJ5 7/123
For residual current protective devices 4/14
For time counters 11/38
Covers for cable lug connections
For 3NP5 7/117
Covers for terminals for circular conductors
For 8US 10/15
CubicleBUS modules 1/43

20

20/36

Siemens LV 10.1 2011

Current relays 12/16


Current transformer busbars 7/83
For 3NJ62 7/83, 7/85
Current transformers 2/91 ... 2/93, 7/82, 11/39, 12/27
For 3NJ4/3NJ5 7/127
For 3NJ62 7/73, 7/82, 7/84, 7/86
Cylindrical fuse bases
SITOR 5/60
Cylindrical fuse holders 5/20, 5/21
SITOR 5/60
Cylindrical fuse links 5/19, 5/20
SITOR 5/59, 5/60

D
Data keys
For digital time switches 8/41
DC isolators 8/20
Delay timers 8/51
Device adapters for 8US 10/16
Device holders
For 8US 10/16
DIAZED
Bus-mounting bases 5/15, 10/30, 10/31
Fuse bases 5/14
Fuse links 5/13, 5/14
Digital ammeters 11/34
Digital time switches 8/40, 8/41
Astro 8/40
Data keys 8/41
Expert 8/41
Mini 8/40
Profi 8/40
Software 8/41
Top 8/40
USB adapters 8/41
Digital voltmeters 11/34
Direct current
Non-automatic air circuit breakers 1/50 ... 1/54
Direct operating mechanisms
For 3KA/3KE 7/41, 7/42
Direct voltage monitors 12/13
Distance compensation
For 3NJ4/3NJ5 7/126
Door-coupling rotary operating mechanisms
For 3K switch disconnectors 7/57 ... 7/63
Door-coupling rotary operating mechanisms IP65
For 3KA/3KE 7/40, 7/41, 7/42
For 3KL 7/48, 7/49
For 3KM 7/55, 7/56
Double pushbuttons 8/10, 8/11
Dusk switches 12/37
Light sensor 12/37

E
ECG control switches 8/50
E-counters 11/8
Three-phase 11/8
EFM 10
For 3NP1 7/90
EFM 20
For 3NP1 7/90
EFM 25
For 3NP1 7/90
Electromechanical fuse monitoring
For 3NP1 7/90
Electronic fuse monitoring
For 3NP1 7/90
For 3NP5 7/112, 7/113
Electronic fuse monitoring with DC monitoring
For 3NP1 7/90
Electronic fuse monitors
For 3NP5 7/112, 7/113
Electronic releases 1/7 ... 1/22, 1/34, 1/35, 2/10 ... 2/29, 2/34 ... 2/51
EMERGENCY STOP modules 12/32
End and intermediate holders
For 8US 10/7, 10/10, 10/11
End caps
For busbars 4/25, 8/23
Acc. to UL 508 3/45, 5/32
Standard 3/28, 3/41, 3/42
End covers
For 8US 10/11

Siemens AG 2011

Appendix
Subject index
Energy counters 11/8
Three-phase 11/8
Energy management 11/2
Energy-saving timers 8/50
ETU electronic releases 1/7 ... 1/22, 1/34, 2/12 ... 2/29, 2/40 ... 2/51
Expansion fault signaling units 12/31
Expansion modules for E-counters 11/12
Expansion modules for power monitoring devices
PAC 4DI/2DO 11/31
PAC PROFIBUS DP 11/29
PAC RS 485 11/30
Extension terminals 10/12

F
Fault signal contacts (FC)
For miniature circuit breakers 3/31, 3/52
Fault signaling units 12/31
Centralized fault signaling unit 12/31
Expansion fault signaling units 12/31
Feeder terminals 3/59
For 3NP1 7/98
Fixed mounting
Circuit breakers 1/7 ... 1/10, 1/15 ... 1/18, 1/50
Fixed-mounted circuit breakers 2/10 ... 2/54
Connection methods for 2/77 ... 2/82
Fixing clips
For 3NJ4/3NJ5 7/123
Fixing kits
For 3NP1 7/99, 7/101, 7/103
Fixing parts
For miniature circuit breakers 3/34
For residual current protective devices 4/27
Fixing screws
For 3NJ4/3NJ5 7/124
Flashing timers 8/51
Flat copper profile
For 8US 10/13
Flat copper profiles
For 8US 10/7
Flat terminals
3NP1 version 7/92, 7/93, 7/97
For 3N4/3NJ5 7/121
Front panel
For 3NJ62 7/83, 7/85, 7/87
Fuse bases
DIAZED 5/14
NEOZED 5/9, 5/10
Fuse carriers
For 3NP1 7/99, 7/101, 7/104, 7/105
For 3NP5 7/114
Fuse covers
For 3KL 7/48, 7/49
For 3KM 7/55, 7/56
Fuse links
Class CC fuse system 5/26
Cylindrical fuses 5/20
DIAZED 5/13, 5/14
NEOZED 5/7
Fuse monitor connections
For 3KL 7/48, 7/49
For 3KM 7/55, 7/56
Fuse monitoring
For 3NP5 7/110
Fuse monitors 5/43, 12/18
Fuse partitions
For 3KL 7/48, 7/49
For 3KM 7/55, 7/56
Fuse pullers
For LV HRC fuse links 5/49
Fuse switch disconnectors
MINIZED 5/8
Fuse systems 5/2 ... 5/64
Busbars 5/29 ... 5/32
Class CC 5/26
Class CC fuse system 5/26
Cylindrical fuse systems 5/19 ... 5/21
DIAZED 5/13 ... 5/17
DIAZED fuse systems 5/13 ... 5/17
LV HRC fuse bases 5/46 ... 5/49
LV HRC fuse links 5/35 ... 5/41
LV HRC signal detectors 5/43
NEOZED 5/7 ... 5/11
NEOZED fuse systems 5/7 ... 5/11
Photovoltaic fuses 5/64

Fuse tongs 5/60


Fuse-base covers
For LV HRC fuse bases 5/49
Fuses
For 3KL 7/50
For 3KM 7/50
For 3NJ4/3NJ5 7/126
For 3NP5 7/115

G
Generator protection 2/16 ... 2/29, 2/46 ... 2/51
Grounding brackets
For 3KA/3KE 7/41, 7/42
Grounding set
For 3NJ4/3NJ5 7/124
Group switches 8/6
GSM alarm modules 12/30
Guide frames
For circuit breakers 1/30 ... 1/33, 1/53 ... 1/54
Guide rails
For 3NJ62 7/88

H
Handle coupler
For residual current protective devices 4/22
Handle locking devices
For control switches 8/7
For miniature circuit breakers 3/34, 3/53
For ON/OFF switches 8/19
Handle with masking plate
For door-coupling rotary operating mechanisms 7/62
High speed closing
3NP5 version 7/108, 7/109, 7/110, 7/111, 7/112, 7/113
Holder
For front panel installation 3/35, 8/41, 8/48
Holders for ammeters
For 3NJ62 7/83, 7/85, 7/87

I
Immersion electrodes
For level relays 12/34
Infeeds
For 8US 10/14
Inscription labels 3/34, 4/27
For 3LD 7/21, 7/22, 7/23, 7/24, 7/25
Insta contactors
AC technology 8/35, 8/36
DC technology 8/32
Instabus KNX 11/13
Insulation monitors 12/20, 12/26
Interlocks 1/26, 1/36
For circuit breakers 2/83 ... 2/88
Intermediate frames 3/35
Isolating links
For 3NJ4/3NJ5 7/126
For LV HRC fuse bases 5/49

Siemens LV 10.1 2011

20/37

20

Siemens AG 2011

Appendix
Subject index
K
Knob-operated mechanism
For 3LD 7/23

L
Labeling systems 3/34, 4/27
LAN couplers 11/22
Lateral modules
For 8US 10/22
Leakage current measurement devices 4/14
LEDs
For light indicators 8/14
For pushbuttons 8/11
Level relays 12/34
Light indicators 8/13
Light sensor
For dimmer switch 12/37
Lighting timers 8/50
Lightning arresters 6/4
Line circuit relays 12/35
Link rails 3/59
For 3NP1 7/98
For overvoltage protection devices 6/13
Lock
For miniature circuit breakers 3/34
Locking caps 5/8
Locking devices 1/27, 1/35
For 3NP1 7/99, 7/101, 7/104, 7/105
For miniature circuit breakers 3/34
For residual current protective devices 4/14
Locking mechanisms 1/27, 1/36
LV HRC bus-mounting bases 5/47
LV HRC contact covers
LV HRC bus-mounting bases 5/48
LV HRC fuse bases 5/46 ... 5/49
LV HRC fuse links 5/35 ... 5/41
LV HRC signal detectors 5/43
Lyre-shaped fuse covers
For 3KL 7/48

M
Magnetic releases 2/30 ... 2/31, 2/52 ... 2/53
Main connections 1/28, 1/45 ... 1/46, 2/7
Main miniature circuit breakers (SHU) 3/56, 3/57
Male connectors
For lightning arresters 6/12
For surge arresters 6/12, 6/17
M-Bus 11/13
Measuring devices
Analog 11/32
Three-phase 11/3 ... 11/40
Measuring selector switches 11/40
Mechanical coupling of operating handles
For 3NJ4/3NJ5 7/126
Mechanical time switches 8/47, 8/48
MFM
For 3NP1 7/90
Miniature circuit breakers 3/2 ... 3/59
10 000 A, high current 3/15
10 000 A, universal current 3/16, 3/17
10 000 A 3/11 ... 3/14
15 000 A 3/18 ... 3/20
25 kA 3/21, 3/22
6000 A 3/6, 3/7
Acc. to UL 489 and IEC 3/48 ... 3/53
Additional components 3/31 ... 3/35
Busbars 3/28, 3/39 ... 3/42, 3/45, 3/53
Circuit breaker terminals 3/59
Compact range 1+N in 1 MW 3/28
High current, 10 000 A 3/15
Main miniature circuit breakers (SHU) 3/56, 3/57
RC units 3/32, 3/33
Universal current, 10 000 A 3/16, 3/17
With plug-in terminal 3/25
MINIZED
Fuse switch disconnectors 5/8
Switch disconnectors 5/8
Molded case circuit breakers 2/1 ... 2/98
Molded-plastic enclosures 3/35, 4/27
Molded-plastic masking frames
For 3NP5 7/114, 7/117

20

20/38

Siemens LV 10.1 2011

Monitoring devices 12/2 ... 12/41


Current relays 12/16
Dusk switches 12/37
EMERGENCY STOP modules 12/32
Fault signaling units 12/31
Fuse monitors 12/18
GSM alarm modules 12/30
Insulation monitors 12/20
Level relays 12/34
Line circuit relays 12/35
Monitoring of medical premises 12/26, 12/27
Network switchover control 12/8
p.f. controller 12/40
Phase monitors 12/19
Phase sequence monitors 12/19
Priority switches 12/17
Residual current monitors 12/10
Temperature controllers 12/39
Thermistor motor protection relays 12/41
Voltage relays 12/13
Monitoring of medical premises 12/26, 12/27
Motor protection 2/26 ... 2/29
Motor starter protectors/Circuit breakers
Generator protection 2/16 ... 2/29
Motor protection 2/26 ... 2/29
Starter protection 2/30 ... 2/31
System protection 2/10 ... 2/25
Mounting hook
For 3NJ4/3NJ5 7/126
Mounting plates 3/57
Moving-iron ammeters
For 3NJ62 7/83, 7/85, 7/87
Moving-iron measuring instruments 7/83
For 3NJ62 7/83, 7/85, 7/87
Multicounters 11/19
Multi-function plugs
For 3NJ62 7/73, 7/83, 7/85, 7/87
Multifunction timers 8/51
Multimeters 11/16

N
N conductor monitors 12/14
N or PE terminals
For 3LD 7/21, 7/22, 7/25
N-conductor connectors 8/19
NEOZED
Adapter sleeve fitters 5/11
Adapter sleeves 5/11
Busbar adapters 5/11
Caps 5/10
Covers 5/10
Fuse bases 5/9, 5/10
Retaining springs 5/11
Screw caps 5/11
NEOZED bus-mounting bases 10/30
NEOZED fuse links 5/7
Network switchover control 12/8
Non-automatic air circuit breakers
Air 1/1 ... 1/54
Direct current 1/50 ... 1/54
Non-automatic molded case circuit breakers 2/30 ... 2/31, 2/52 ... 2/53

O
OFF switches 8/17 ... 8/19
Off-delay timers 8/51
ON-OFF switch 8/17 ... 8/19
Operating mechanisms
For circuit breakers 1/23, 1/25, 1/40, 2/55, 2/56, 2/62 ... 2/69
Operating mechanisms for fixed mounting
For 3KA/3KE 7/40
Operating protective covers
For miniature circuit breakers 3/57
Outgoing modules for PE/N
For 8US 10/14
Overvoltage protection devices 6/2 ... 6/18
Accessories for surge arresters 6/12
Combination surge arresters 6/6
Configuration 6/14
Lightning arresters 6/4
Link rails 6/13
Surge arresters 6/9, 6/10, 6/11, 6/17
Overvoltage relays 12/13

Siemens AG 2011

Appendix
Subject index
P
p.f. controller 12/40
PAC PROFIBUS DP 11/29
PAC RS 485 11/30
PAC1500 11/6
PAC1500 single-phase counters 11/9
PAC1500 three-phase counters 11/6
PAC3100 11/23, 11/26
PAC3100 power monitoring devices 11/23, 11/26
PAC3200 11/23, 11/27, 13/15
PAC3200 block library for SIMATIC WinCC 13/15
PAC3200 power monitoring devices 11/23, 11/27
PAC4200 11/23, 11/28
PAC4200 power monitoring devices 11/23, 11/28
Padlocks 3/34, 3/53, 4/14
Parallel switches
For 3KA/3KE 7/41, 7/42
Parking position
For 3NJ4/3NJ5 7/119
Partition
For 8US 10/13
Partitions
For LV HRC bus-mounting bases 5/48
For LV HRC fuse bases 5/48, 5/49
Phase connectors 8/19
Phase monitors 12/19
Phase sequence monitors 12/19
Photovoltaic
Cylindrical fuse holders 5/64
Cylindrical fuse links 5/64
DC isolators 8/20
Photovoltaic fuses 5/64
Planning 13/7
Planning the Power Distribution System with SIMARIS 13/4 ... 13/6
Plug-in version
Circuit breakers 2/70 ... 2/75
Power Management System 11/2
Power supply units 9/8, 12/30
Priority switches 12/17
Prism terminal
For 3NJ4/3NJ5 7/125
For 3NP1 7/100, 7/102
PROFIBUS 1/44
PROFIBUS DP 11/29
Protective devices with device holder 1/34
Pulse counters
Electronic 11/36
Mechanical 11/36
Pushbuttons 8/10, 8/11
Control pushbuttons 8/10
Double pushbuttons 8/10, 8/11

Q
Quartz-clock time switches 8/47

R
Rated current modules 1/24, 1/34
Rating Plug 1/24, 1/34
RC units
For miniature circuit breakers 3/32, 3/33
For residual current protective devices 4/16, 4/17
RCBO 4/19 ... 4/22
RCCB protective socket outlets 4/26
RCCB socket outlets (SRCDs) 4/26
RCCBs 4/5 ... 4/8
RCD modules
For circuit breakers 2/76
Reach-around protection
For 3NP1 7/99, 7/101, 7/103, 7/104, 7/105
Reducers 5/8
For door-coupling rotary operating mechanisms 7/62
REG socket outlets 9/10, 9/11
Remote control switches 8/26
Remote controlled mechanisms (RC)
For miniature circuit breakers 3/31
For residual current protective devices 4/14
Residual current monitors 12/10

Residual current protective devices 4/2 ... 4/28


Accessories 4/27
Additional components 4/14
Busbars 4/24, 4/25
Leakage current measurement devices 4/14
RC units 4/16, 4/17
RCBO 4/19 ... 4/22
RCCB 4/5 ... 4/8
RCCB socket outlets (SRCDs) 4/26
Residual-current operated circuit breakers 4/28
SIGRES 4/7, 4/8
SIQUENCE RCCBs 4/10 ... 4/12
Residual-current operated circuit breakers 4/28
Retaining springs
For NEOZED 5/11
Rotary operating mechanisms
For 3LD 7/21, 7/22, 7/25
For switch disconnectors 7/28
RS 485 11/13

S
Saddle terminals
For 3NJ4/3NJ5 7/125
For 3NP1 7/100, 7/102, 7/105
Screw adapters
For DIAZED fuse bases 5/16
Screw caps
For DIAZED fuse bases 5/15
For NEOZED fuse bases 5/11
Screw holders
For 8US 10/25
Sealable covers
For 3NP1 7/98
Sealing lugs
For 3NP5 7/117
Selection and ordering data (paper) 7/82
Selector switches
For ammeters 11/40
For voltmeters 11/40
Series remote control switches 8/26
Shaft couplings
For door-coupling rotary operating mechanisms 7/62
Short-time relays 12/14
Shunt releases
For circuit breakers 1/23, 1/40, 2/57, 2/59 ... 2/60
Shunt trips (ST)
For miniature circuit breakers 3/31, 3/52
Shutter/blind remote control switches 8/26
Signaling combination
For insulation monitors 12/27
Signaling panels 12/26
SIMARIS curves 13/6
SIMARIS design 13/4
SIMARIS project 13/5
SIMATIC PCS 7 Library PAC3200 13/13
SIMATIC PCS 7 powerrate 13/9, 13/10
SIMATIC WinCC powerrate 13/11, 13/12
Single-phase measuring devices
Analog measuring devices 11/32
Digital measuring devices 11/34
Time and pulse counters 11/36
Time counters for front-panel mounting 11/38
SIQUENCE RCCBs 4/10 ... 4/12
SITOR fuses
For 3KL 7/50
For 3KM 7/50
For 3NP5 7/115
SITOR semiconductor fuses 5/50 ... 5/64
Cylindrical fuse design 5/59, 5/60
LV HRC design 5/51 ... 5/57
NEOZED and DIAZED, SILIZED design 5/62
Socket outlets
For modular installation devices 9/10, 9/11
SCHUKO 4/26
Soft-starting devices 8/37
Software
For digital time switches 8/41
Spacers
For 8US 10/24, 10/25
For Control Switches 8/7
For Insta contactors 8/32
For miniature circuit breakers 3/34
For ON/OFF switches 8/19
For switching relays 8/29

Siemens LV 10.1 2011

20/39

20

Siemens AG 2011

Appendix
Subject index
Stairwell lighting timers 8/50
Starter protection 2/30 ... 2/31
Stud terminal
For 3NJ4/3N5 7/121
Summation current transformer
For residual current monitors 12/10
Support rails
For 8US 10/25
Supports for blanking covers
For 8US 10/11
Surge arresters
For measuring and control technology 6/17
Type 2 6/9, 6/10
Type 3 6/11
Switch disconnectors 7/27
MINIZED 5/8
Switch ES Power 1/43, 13/19
Switching devices 8/2 ... 8/52
Busbars 8/23
Control switches 8/6
DC isolators 8/20
Insta contactors
AC technology 8/35, 8/36
DC technology 8/32
Light indicators 8/13
OFF switches 8/17 ... 8/19
ON-OFF switch 8/17 ... 8/19
Pushbuttons 8/10, 8/11
Remote control switches 8/26
Soft-starting devices 8/37
Switching relays 8/29
Timers
Digital time switches 8/40, 8/41
Mechanical time switches 8/47, 8/48
Timers for buildings 8/50
Timers for industrial applications 8/51
Switching relays 8/29
Switching shafts
For 3LD 7/22, 7/23, 7/24
Switchover device
For medical premises 12/26
Synchronous time switches 8/47
System covers
For 3NP1 7/99, 7/101, 7/103, 7/104, 7/105
System protection 2/10 ... 2/25, 2/34 ... 2/51

Time counters
Electronic 11/36
For front-panel mounting 11/38
Mechanical 11/36
Time switches
Digital 8/40, 8/41
Mechanical 8/47, 8/48
Quartz 8/47
Synchronous 8/47
Timers 8/38 ... 8/52
For buildings 8/50
For fans 8/50
For industry 8/51
Time switches
Digital 8/40, 8/41
Mechanical 8/47, 8/48
Touch protection
For RCCBs 4/27
Touch protection covers
For busbars 4/25
Acc. to UL 489 3/53
Acc. to UL 508 3/45, 5/32
Standard 3/40
Transformers
Bell transformers 9/4
For permanent load 9/6
Transformers, bells and socket outlets 9/2 ... 9/12
Triple terminals
For 3NP1 7/98, 7/100
Two-way switches 8/6

U
Under and overvoltage relays 12/14
Undervoltage relays 12/13
Undervoltage releases
For circuit breakers 1/23, 1/40, 2/57, 2/59 ... 2/60
Undervoltage releases (UR)
For miniature circuit breakers 3/31
Unequipped section covers
For 3NJ4/3NJ5 7/124
USB adapters
For digital time switches 8/41

V
T
Temperature controllers 12/39
Temperature sensor 12/39
Terminal covers 3/34, 3/35, 3/57, 4/27, 7/82, 8/19, 11/38
For 3KA/3KE 7/40, 7/42
For 3KL 7/48, 7/49, 7/50
For 3KM 7/55, 7/56
For 3LD 7/21, 7/22, 7/23, 7/25
For 3NJ62 7/84, 7/86
Sealable 8/32, 8/35, 8/36
Terminal sets
For 8US 10/14, 10/15
Terminal strips
For 3NJ4/3NJ5 7/126
Terminals 7/84
Covers 7/28
For 3NJ62 7/82, 7/86
For 8US 10/15
For busbars 4/25
Acc. to UL 489 3/53
Acc. to UL 508 3/45, 5/32
Standard 3/28, 3/42
Terminals for circular conductors
For 8US 10/15
Test combination
For insulation monitors 12/27
Test panels 12/26
Thermal-magnetic releases 2/10 ... 2/13, 2/34 ... 2/39
Thermistor motor protection relays 12/41
Three-phase busbar
For 3NP1 7/98
Three-phase measuring devices 11/3 ... 11/40
Current transformers 11/39
E-counters 11/8
LAN couplers 11/22
Measuring selector switches 11/40
Multicounters 11/19
Multimeters 11/16

20

20/40

Siemens LV 10.1 2011

Voltage relays 12/13, 12/14, 12/27


Voltmeter selector switches 11/40
Voltmeters
Analog 11/32
Digital 11/34

W
Wall enclosures 3/35, 4/27
Wiper timers 8/51
Wiring 1/35
Withdrawable bridging units 1/48
Withdrawable grounding units 1/48
Withdrawable short-circuits 1/48
Withdrawable version
Circuit breakers 1/11 ... 1/14, 1/19 ... 1/22, 1/51 ... 1/52, 2/70 ... 2/75

Siemens AG 2011

Appendix
Order number index
incl. export markings

Overview
Order No.

Export markings
ECCN

Page

Order No.

AL

3K

Export markings
ECCN

AL

3LD22 17

Page

7/15

3KA

7/34

3LD22 2

7/8, 7/10

3KC90 00-8TL3

EAR99

12/8

3LD22 3

7/16 ... 17, 7/20

3KC90 00-8TL7

5D992

12/8

3LD22 4

7/13

3KE

7/36 ... 38

3LD22 5

7/7, 7/9

3KL

7/45 ... 46

3LD22 6

7/18 ... 20

3KM

7/54

3LD23 0

EAR99

7/6, 7/10

3KX22 1

7/36, 7/41 ... 42

3LD23 1

EAR99

7/11 ... 12, 7/14

3KX22 3

7/41 ... 42

3LD23 3

7/16 ... 17

3KX22 50

7/41 ... 42

3LD24 05-0

7/6

3KX22 52-0

7/42

3LD24 05-1

EAR99

7/6

3KX22 52-1

7/41 ... 42

3LD24 05-3

EAR99

7/10

3KX31

7/40, 7/49, 7/56

3LD24 05-7

EAR99

7/10

3KX35 0

7/48 ... 49, 7/55 ... 56

3LD24 1

EAR99

7/11 ... 12, 7/14

3KX35 1

7/35, 7/40, 7/47 ... 48, 7/55

3LD24 3

7/16 ... 17

3KX35 2

7/47 ... 48, 7/55

3LD25 04-0

7/6

3KX35 3

7/35, 7/40, 7/47 ... 49, 7/55

3LD25 04-1

7/6

3KX35 52-3D

7/40, 7/48, 7/55

3LD25 04-3

7/10

3KX35 52-3E

7/40, 7/49, 7/56

3LD25 14-0

7/11 ... 12

3KX35 53

7/40, 7/48, 7/55

3LD25 14-1

7/11 ... 12

3KX35 56

7/35, 7/47

3LD25 17

7/15

3KX35 57

7/40 ... 41, 7/49, 7/56

3LD25 2

7/10

3KX35 6

7/50

3LD25 3

7/16 ... 17

3KX36

7/50

3LD25 4

7/13

3KY22 0

7/41

3LD25 5

7/7

3KY22 32

7/42

3LD25 6

7/18 ... 19

3KY22 34

7/42

3LD27 04-0

7/6

3LD27 04-1

7/6

3LD
3LD20 03-0

7/6

3LD27 1

7/11 ... 12

3LD20 03-1TL

7/6

3LD27 2

7/10

3LD20 03-1TP

7/6

3LD27 3

7/16 ... 17

3LD20 03-2

7/6

3LD27 6

7/18 ... 19

3LD20 13

7/11 ... 12

3LD28

7/6, 7/11 ... 12, 7/16 ... 18

3LD20 17

7/15

3LD92 00-2

7/21

3LD20 2

7/8

3LD92 00-5B

7/6 ... 9, 7/21 ... 25

3LD20 3

7/16 ... 17

3LD92 00-5BF

7/21 ... 25

3LD20 4

7/13

3LD92 00-5C

3LD20 5

7/7, 7/9

7/12 ... 13, 7/17 ... 18,


7/21 ... 25

3LD20 6

7/18

3LD92 00-5CF

7/21 ... 25

3LD21 03-0

7/6

3LD92 00-6

7/21 ... 25

3LD21 03-1

7/6

3LD92 01

7/21

3LD21 03-2

7/6

3LD92 05

7/21 ... 22, 7/24 ... 25

3LD21 03-3

7/10

3LD92 20

7/8 ... 9, 7/16 ... 17, 7/22

3LD21 03-4

7/10

3LD92 21

7/22

3LD21 13-0

7/11 ... 12

3LD92 24

7/21 ... 22

3LD21 13-1

7/11 ... 12

3LD92 40-0

7/16 ... 17, 7/23

3LD21 13-3

7/14

3LD92 40-2

EAR99

7/23

3LD21 13-4

7/14

3LD92 41

EAR99

7/23

3LD21 2

7/8, 7/10

3LD92 42

7/23

3LD21 3

7/16 ... 17

3LD92 43

EAR99

7/23

3LD21 4

7/13

3LD92 45

EAR99

7/23

3LD92 50

7/6 ... 7, 7/13, 7/16 ... 17,


7/24

3LD92 51

7/24

3LD92 56

7/21 ... 22, 7/24

3LD92 80

7/6, 7/11 ... 12, 7/16 ... 18,


7/25

3LD92 81

7/25

3LD21 5

7/7, 7/9

3LD21 6

7/18 ... 19

3LD22 03-0

7/6

3LD22 03-1

7/6

3LD22 03-3

7/10

3LD22 13-0

7/11 ... 12

3LD22 13-1

7/11 ... 12

Siemens LV 10.1 2011

20/41

20

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

Export markings

Page

Order No.

Page

ECCN

AL

ECCN

AL

3LD92 84

7/24 ... 25

3NJ49 11-3

7/124

3LD92 86

7/21 ... 25

3NJ49 11-4

7/125

3NJ49 11-5

7/125

3NA, 3NC
3NA

5/35 ... 40

3NJ49 11-6A

7/125

3NC10 00

EAR99H

5/60

3NJ49 11-6B

7/125

3NC10 03

5/59

3NJ49 11-6C

7/126

3NC10 06

5/59

3NJ49 12-1A

7/123

3NC10 08

5/59

3NJ49 12-1D

7/123

3NC10 1

5/59

3NJ49 12-1E

7/123

3NC10 2

5/59

3NJ49 12-1F

7/123

3NC10 32

5/59

3NJ49 12-2

7/123

3NC10 38

EAR99H

5/60

3NJ49 12-3

7/124

3NC10 38-1

5/60

3NJ49 13

7/126

3NC10 38-2

5/60

3NJ49 14-8A

7/126

3NC10 38-3

5/60

3NJ49 14-8B

EAR99

7/126

3NC10 9

5/60

3NJ49 15-1B

7/126

3NC14 0

5/59

3NJ49 15-1C

7/126

3NC14 1

5/59

3NJ49 15-1E

7/127

3NC14 2

5/59

3NJ49 15-1F

7/127

3NC14 3

5/59

3NJ49 15-2B

7/126

3NC14 4

5/59

3NJ49 15-2C

7/126

3NC14 50

5/59

3NJ49 15-2D

7/127

3NC14 51

EAR99H

5/60

3NJ49 15-2E

7/127

3NC14 51-1

5/60

3NJ49 15-2F

7/127

3NC14 9

5/60

3NJ49 15-2G

7/127

3NC2

5/51, 5/59 ... 60, 7/51,


7/116

3NJ49 15-2H

7/127

3NJ49 15-2J

7/127

3NJ49 15-2K

7/127

3NJ49 18-0A

7/123

3NJ49 18-0DA

7/124

3NJ49 18-0DB

7/124

3NJ49 18-0DC

7/124

3NJ49 18-0E

7/124

3NJ49 18-1

7/126

3NJ50

7/121 ... 122

5/55, 7/51, 7/115

3NJ56

7/121

7/124

3NC3

5/54 ... 56

3NC5

5/57

3NC73 2

5/57

3NC73 3

5/57

3NC8

5/51 ... 52, 7/51, 7/116

3ND, 3NE, 3NG, 3NH


3ND

5/41

3NE1

5/51 ... 53, 7/50 ... 51,


7/115

3NE32

3NE33

5/55, 7/51, 7/116

3NJ59

3NE34

5/55

3NJ62 02

7/69

5/57

3NJ62 03-1AA

7/69

7/69

3NE35

3NE36 2

5/55

3NJ62 03-1AB

3NE36 35-0

5/55

3NJ62 03-1AC

7/69

5/55

3NJ62 03-3AA

7/69

7/69

3NE36 35-6

3NE36 36

5/55

3NJ62 03-3AB

3NE36 37

5/55

3NJ62 03-3AC

7/69

3NE4

5/54, 5/57, 7/51,


7/115 ... 116

3NJ62 03-4

7/69

3NJ62 04

7/70

3NE5

5/56

3NJ62 12

7/69

3NE6

5/57

3NJ62 13-1AA

7/69

3NE7

5/56

3NJ62 13-1AB

7/69

3NE8

5/52, 5/54, 7/51, 7/115

3NJ62 13-1AC

7/69

3NE94

5/57

3NJ62 13-3AA

7/69

3NE96 2

5/57

3NJ62 13-3AB

7/69

3NE96 3

5/57

3NJ62 13-3AC

7/69

3NG

5/49

3NJ62 13-4

7/69

3NH

5/46 ... 48, 10/32

3NJ62 14

7/70

3NJ62 22

7/69

3NJ

20

Export markings

3NJ41

7/121 ... 122

3NJ62 23-1AA

7/69

3NJ49 10

7/124

3NJ62 23-1AB

7/69

3NJ49 11-1

7/125

3NJ62 23-1AC

7/69

3NJ49 11-2

7/125

3NJ62 23-3AA

7/69

20/42

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

Export markings

Page

Order No.

Export markings

Page

ECCN

AL

ECCN

AL

3NJ62 23-3AB

7/69

3NP19 0

7/99, 7/101, 7/103 ... 105

3NJ62 23-3AC

7/69

3NP19 20

7/99

3NJ62 23-4

7/69

3NP19 23-1BD

7/98

3NJ62 24

7/70

3NP19 23-1BE

EAR99

7/98, 7/100

3NJ62 32

7/69

3NP19 23-1BF1

EAR99

7/98

3NJ62 33-1AA

7/69

3NP19 23-1BF2

EAR99

7/98

3NJ62 33-1AB

7/69

3NP19 23-1BF3

EAR99

7/98

3NJ62 33-1AC

7/69

3NP19 23-1BF4

EAR99

7/98

3NJ62 33-3AA

7/69

3NP19 23-1BF5

7/98

3NJ62 33-3AB

7/69

3NP19 23-1BG

7/98

3NJ62 33-3AC

7/69

3NP19 23-1C

7/99

3NJ62 33-4

7/69

3NP19 23-1D

7/99

3NJ62 34

7/70

3NP19 23-1E

7/99

3NJ62 4

7/71

3NP19 23-1G

7/99

3NJ62 5

7/71

3NP19 30

7/101

3NJ62 6

7/71 ... 72

3NP19 33-1BA

7/100

3NJ62 7

7/71 ... 72

3NP19 33-1BB

7/100

3NJ62 8

7/71 ... 72

3NP19 33-1BC

7/100, 10/23

3NJ62 9

7/71 ... 72

3NP19 33-1BE

EAR99

7/100

3NJ69 0

7/82 ... 88

3NP19 33-1BG

7/100

3NJ69 1

7/88

3NP19 33-1C

7/101

3NJ69 20-2

7/82

3NP19 33-1D

7/101

3NJ69 20-3B

7/82, 7/84

3NP19 33-1E

7/101

3NJ69 20-3D

7/83

3NP19 33-1G

7/101

3NJ69 20-3E

7/83, 7/85

3NP19 40

7/103 ... 105

3NJ69 20-3F

EAR99

7/82

3NP19 43-1BA

7/102

3NJ69 23-1B

7/82

3NP19 43-1BB

EAR99

7/102

3NJ69 23-1D

7/82

3NP19 43-1BG

7/102, 7/104 ... 105

3NJ69 23-1E

7/82

3NP19 43-1C

7/103 ... 105

3NJ69 23-4

7/83

3NP19 43-1D

7/103

3NJ69 24

7/82

3NP19 43-1E

7/103

3NJ69 30-2

7/84

3NP19 43-1G

7/103

3NJ69 30-3B

7/84

3NP19 53-1BA

7/104

3NJ69 30-3D

7/85

3NP19 53-1BB

EAR99

7/104

3NJ69 30-3FB

EAR99

7/84

3NP19 53-1BG

7/104 ... 105

3NJ69 30-3FC

EAR99

7/84

3NP19 53-1C

7/104

3NJ69 30-3FE

7/84

3NP19 53-1D

7/104

3NJ69 33-1B

7/84

3NP19 53-1G

7/104

3NJ69 33-1D

7/84

3NP19 63-1BA

7/105

3NJ69 33-1E

7/84

3NP19 63-1BB

EAR99

7/105

3NJ69 33-4

7/85

3NP19 63-1C

7/105

3NJ69 34

7/84

3NP19 63-1D

7/105

3NJ69 40-2

7/86

3NP19 63-1G

7/105

3NJ69 40-3B

7/86

3NP5

7/108 ... 113

3NJ69 40-3E

7/87

3NW

3NJ69 40-3FB

EAR99

7/86

3NW1

5/26

3NJ69 40-3FC

7/86

3NW20 1

5/26

3NJ69 40-3FE

7/86

3NW20 2

5/26

3NJ69 43-1C

7/86

3NW20 3

5/26

3NJ69 43-1D

7/86

3NW20 4

5/26

3NJ69 43-1E

7/86

3NW20 5

5/26

3NJ69 43-4

7/87

3NW20 6

5/26

3NJ69 44

7/86

3NW20 8

EAR99H

5/26

3NJ69 5

7/87

3NW21

5/26

3NW22

5/26

3NP
3NP11 2

7/92, 7/94 ... 97, 10/23

3NW3

5/26

3NP11 3

7/92, 7/94 ... 97, 10/23

3NW60 01-1

5/19

3NP11 4

7/93, 7/96 ... 97, 10/23

3NW60 01-4

5/64

3NP11 5

7/93, 7/96 ... 97, 10/23

3NW60 02

5/19

3NP11 6

7/93, 7/96 ... 97, 10/23

3NW60 03-1

5/19

Siemens LV 10.1 2011

20/43

20

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

Export markings

Page

Order No.

Page

ECCN

AL

ECCN

AL

3NW60 03-4

5/64

3NY19 03

7/117

3NW60 04-1

5/19

3NY19 07

7/117

3NW60 04-4

5/64

3NY19 10

7/114

3NW60 05-1

5/19

3NY19 11

7/114

3NW60 05-4

5/64

3NY19 15

7/114

3NW60 06-1

5/19

3NY19 4

7/117

3NW60 06-4

5/64

3NY3

7/114

3NW60 07

5/19

3NY4

7/114

3NW60 08-1

5/19

3SB, 3TX, 3UF

3NW60 08-4

5/64

3SB

3NW60 1

5/19

2/61, 7/40, 7/48 ... 49,


7/55 ... 56

3NW61

5/19

3TX

2/59 ... 60, 7/117

3UF

2/98

3NW62

5/19

3NW63

5/19

3NW70 13

5/20

3NW70 13-4

5/64

3NW70 14

3NW70 23

3NW70 23-4

3NW70 24

3VL
3VL17 0

EAR99

2/10 ... 11, 2/34 ... 37

3VL17 1

EAR99

2/10 ... 11, 2/30 ... 31,


2/34 ... 37, 2/52 ... 53

5/20, 5/64

3VL17 2

EAR99

2/10 ... 11, 2/34 ... 37

5/20

3VL17 9

EAR99

2/10 ... 11, 2/34 ... 37

5/64

3VL27 05

EAR99

5/20, 5/64

2/12 ... 13, 2/34 ... 35,


2/38 ... 39

3NW70 33

5/21

3VL27 06

EAR99

3NW70 33-1

5/24

3NW70 34

5/20, 5/24

2/12 ... 13, 2/20 ... 21,


2/24 ... 25, 2/28 ... 31,
2/34 ... 35, 2/38 ... 39,
2/44 ... 47

3NW70 53

5/20

3VL27 08

EAR99

3NW70 54

5/20

2/12 ... 13, 2/34 ... 35,


2/38 ... 39

3NW70 63

5/21

3VL27 10-1C

EAR99

2/20, 2/24, 2/28, 2/44, 2/46

3NW70 64

5/20

3VL27 10-1D

EAR99

2/12, 2/30

EAR99

2/34, 2/38, 2/52

3NW71

5/20 ... 21

3VL27 10-1E

3NW72

5/20 ... 21

3VL27 10-2C

EAR99

2/21, 2/25, 2/29, 2/45, 2/47

3NW73 13

5/20

3VL27 10-2D

EAR99

2/13, 2/31

3NW73 14

5/20

3VL27 10-2E

EAR99

2/35, 2/39, 2/53

3NW73 23

5/20

3VL27 10-3C

EAR99

2/21, 2/25, 2/29, 2/45, 2/47

3NW73 24

5/20

3VL27 10-3D

EAR99

2/13, 2/31

3NW73 33

5/21

3VL27 10-3E

EAR99

2/35, 2/39, 2/53

3NW73 34

5/20

3VL27 12

EAR99

3NW73 53

5/20

2/12 ... 13, 2/34 ... 35,


2/38 ... 39

3NW73 54

5/20

3VL27 16

EAR99

3NW73 63

5/21

3NW73 64

5/20

2/12 ... 13, 2/20 ... 21,


2/24 ... 25, 2/28 ... 31,
2/34 ... 35, 2/38 ... 39,
2/44 ... 47, 2/52 ... 53

3NW74 30

10/31

3VL37 20-1C

EAR99

2/20, 2/24, 2/28, 2/44, 2/46

3NW74 31

10/31

3VL37 20-1D

EAR99

2/12

3NW74 32

10/31

3VL37 20-1E

EAR99

2/34, 2/38

3NW75 1

5/26

3VL37 20-2C

EAR99

2/21, 2/25, 2/29, 2/45, 2/47

3NW75 2

5/26

3VL37 20-2D

EAR99

2/13

3NW75 33-0

5/26

3VL37 20-2E

EAR99

2/35, 2/39

3NW75 33-1

5/24

3VL37 20-3C

EAR99

2/21, 2/25, 2/29, 2/45, 2/47

3NW75 34

5/24

3VL37 20-3D

EAR99

2/13

3NW79 01

5/21

3VL37 20-3E

EAR99

2/35, 2/39

3NW79 02

5/21

3VL37 25-1C

EAR99

2/20, 2/24, 2/28, 2/44, 2/46

3NW79 03

5/21

3VL37 25-1D

EAR99

2/12, 2/30

3NW79 03-1

5/24

3VL37 25-1E

EAR99

2/34, 2/38, 2/52

3NW8

5/19 ... 20

3VL37 25-2C

EAR99

2/21, 2/25, 2/29, 2/45, 2/47

3VL37 25-2D

EAR99

2/13, 2/31

3VL37 25-2E

EAR99

2/35, 2/39, 2/53

3VL37 25-3C

EAR99

2/21, 2/25, 2/29, 2/45, 2/47

3VL37 25-3D

EAR99

2/13, 2/31

3VL37 25-3E

EAR99

2/35, 2/39, 2/53

3VL47 2

EAR99

2/12 ... 13, 2/30 ... 31,


2/34 ... 35, 2/38 ... 39

3NX, 3NY
3NX

20

Export markings

5/43, 5/48 ... 49

3NY10

7/114

3NY11

7/114, 7/117

3NY12

7/117

3NY13

7/114

3NY14

7/114

3NY15

7/114

20/44

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

3VL47 3

3VL47 4

3VL57 3
3VL57 4

Export markings
ECCN

AL

EAR99

EAR99

EAR99
EAR99

N
N

Page

Order No.

ECCN

AL

2/12 ... 13, 2/20 ... 21,


2/24 ... 25, 2/28 ... 31,
2/34 ... 35, 2/38 ... 39,
2/44 ... 47

3VL92 00-3

EAR99

2/77 ... 78

3VL92 00-4

EAR99

2/71, 2/78

3VL92 10

2/90

2/12 ... 13, 2/20 ... 21,


2/24 ... 25, 2/30 ... 31,
2/34 ... 35, 2/38 ... 39,
2/44 ... 47, 2/52 ... 53

3VL92 15

EAR99

2/78

3VL92 16-4

EAR99

2/77 ... 78

3VL92 16-5GC3

2/76

2/12 ... 13, 2/30 ... 31,


2/34 ... 35, 2/38 ... 39

3VL92 16-5GC4

EAR99H

2/76

3VL92 16-5GD

EAR99H

2/76

2/12 ... 13, 2/34 ... 35,


2/38 ... 39

3VL92 16-8

2/90

3VL92 8

2/90

3VL93 00-3A

EAR99

2/62

3VL93 00-3H

EAR99

2/62, 2/83 ... 85

3VL93 00-3MA

2/66

3VL93 00-3MC

2/66

3VL93 00-3MD

2/66

3VL93 00-3ME

2/66

3VL93 00-3MJ

EAR99

2/66

3VL93 00-3ML

EAR99

2/66

3VL93 00-3MN

EAR99

2/66

3VL93 00-3MQ

EAR99

2/66

3VL93 00-3MS

EAR99

2/66

3VL93 00-3T

EAR99

2/79

3VL93 00-4E

EAR99

2/79

3VL93 00-4P

EAR99

2/70 ... 71

3VL93 00-4R

EAR99

2/79

3VL93 00-4TA

2/79

3VL93 00-4TC

EAR99

2/79

3VL93 00-4TD

EAR99

2/79

3VL93 00-4W

EAR99

2/71

3VL93 00-8B

EAR99

2/83 ... 85, 2/94 ... 95

3VL93 00-8CA3

2/77 ... 79

3VL93 00-8CA4

EAR99

2/77 ... 79

2/21, 2/25, 2/31, 2/45, 2/47,


2/53

3VL93 00-8CB

EAR99

2/77 ... 79

3VL93 00-8CE

2/77 ... 79

2/21, 2/25, 2/31, 2/45, 2/47,


2/53

3VL93 00-8L

EAR99

2/83 ... 85

3VL93 00-8S

EAR99

2/83 ... 85

2/20 ... 21, 2/24 ... 25,


2/44 ... 47

3VL93 20

2/90

2/20 ... 21, 2/24 ... 25,


2/30 ... 31, 2/44 ... 47,
2/52 ... 53

3VL93 21

EAR99

2/83 ... 85

3VL93 24

EAR99

2/79

3VL93 25-5GE3

2/76

2/20, 2/24, 2/30, 2/44, 2/46,


2/52

3VL93 25-5GE4

EAR99H

2/76

3VL93 25-5GF

EAR99H

2/76

3VL93 25-8

2/90

3VL57 50-1C

EAR99

2/28

3VL57 50-1DC

EAR99

2/12

3VL57 50-1DK

2/30

3VL57 50-1E

EAR99

2/34, 2/38

3VL57 50-2C

EAR99

2/29

3VL57 50-2DC

EAR99

2/13

3VL57 50-2DK

2/31

3VL57 50-2E

EAR99

2/35, 2/39

3VL57 50-3C

EAR99

2/29

3VL57 50-3DC

EAR99

2/13

3VL57 50-3DK

2/31

3VL57 50-3E

EAR99

2/35, 2/39

3VL57 63-1C

EAR99

2/20, 2/24, 2/44, 2/46

3VL57 63-1D

EAR99

2/12, 2/30

3VL57 63-1E

EAR99

2/34, 2/38, 2/52

3VL57 63-2C

EAR99

2/21, 2/25, 2/45, 2/47

3VL57 63-2D

EAR99

2/13, 2/31

3VL57 63-2E

EAR99

2/35, 2/39, 2/53

3VL57 63-3C

EAR99

2/21, 2/25, 2/45, 2/47

3VL57 63-3D

EAR99

2/13, 2/31

3VL57 63-3E

EAR99

2/35, 2/39, 2/53

3VL67 80-1

EAR99

2/20, 2/24, 2/30, 2/44, 2/46,


2/52

3VL67 80-2
3VL67 80-3
3VL77 10
3VL77 12

3VL87 16-1

EAR99
EAR99
EAR99
EAR99

EAR99

N
N
N
N

Export markings

Page

3VL87 16-2

EAR99

2/21, 2/25, 2/31, 2/45, 2/47,


2/53

3VL87 16-3

EAR99

2/21, 2/25, 2/31, 2/45, 2/47,


2/53

3VL94 00-1

2/59

3VL94 00-2AB

EAR99

2/59

3VL90 00-4

EAR99

2/70 ... 75

3VL94 00-2AD

EAR99

2/59

3VL90 00-8AP

EAR99

2/84 ... 88

3VL94 00-2AH

EAR99

2/61

3VL90 00-8AQ

EAR99

2/98

3VL94 00-2AJ

EAR99

2/61

3VL90 00-8AU

2/98

3VL94 00-3A

EAR99

2/63

3VL90 00-8AV

EAR99

2/98

3VL94 00-3H

EAR99

2/63, 2/66, 2/85

3VL90 00-8L

EAR99

2/83 ... 88

3VL94 00-3MA

2/66

3VL91 00-3MA

2/66

3VL94 00-3MC

2/66

3VL91 00-3MC

EAR99

2/66

3VL94 00-3MD

2/66

3VL91 00-3MD

EAR99

2/66

3VL94 00-3ME

2/66

3VL91 00-3ME

2/66

3VL94 00-3MJ

2/66

3VL91 00-4

EAR99

2/70, 2/77

3VL94 00-3ML

EAR99

2/66

3VL91 12-5GA

EAR99H

2/76

3VL94 00-3MN

EAR99

2/66

3VL91 12-5GB

EAR99

2/76

3VL94 00-3MQ

EAR99

2/66

3VL91 15

EAR99

2/77

3VL94 00-3MS

EAR99

2/66

3VL91 16

EAR99

2/77

3VL94 00-3T

EAR99

2/79 ... 81

Siemens LV 10.1 2011

20/45

20

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

Page

Order No.

ECCN

AL

3VL94 00-4

EAR99

2/72, 2/79

3WL

3VL94 00-8B

EAR99

2/85, 2/94

3VL94 00-8CA

EAR99

2/79

3VL94 00-8CB3

2/79

3VL94 00-8CB4

EAR99

2/79

3VL94 00-8L

EAR99

2/85

3VL94 40-5GG

2/76

3VL94 40-5GH

EAR99

3VL94 40-8

EAR99

Export markings

Page

ECCN

AL

3WL11

1/7 ... 8, 1/11 ... 12,


1/15 ... 16, 1/19 ... 20

3WL12

1/7 ... 9, 1/11 ... 13,


1/15 ... 17, 1/19 ... 21,
1/50 ... 52

3WL13

1/9 ... 10, 1/13 ... 14,


1/17 ... 18, 1/21 ... 22

2/76

3WL91 11-0AA1

1/34

2/90

3WL91 11-0AA2

1/34

1/34

3VL94 6

EAR99

2/79

3WL91 11-0AA3

3VL95 0

EAR99

2/63, 2/73, 2/80, 2/85 ... 86

3WL91 11-0AA5

1/34

3VL95 6

2/90

3WL91 11-0AA6

1/34

1/39

3VL96 00-3A

EAR99

2/63 ... 64

3WL91 11-0AB01

3VL96 00-3H

EAR99

2/63 ... 64, 2/66, 2/86 ... 87

3WL91 11-0AB02

1/39

3VL96 00-3MA

2/66

3WL91 11-0AB03

1/39

1/39

3VL96 00-3MC

2/66

3WL91 11-0AB04

3VL96 00-3MD

2/66

3WL91 11-0AB07

1/39

3VL96 00-3ME

2/66

3WL91 11-0AB08

1/39

1/39

3VL96 00-3MJ

EAR99

2/66

3WL91 11-0AB10

3VL96 00-3ML

EAR99

2/66

3WL91 11-0AB12

1/39

3VL96 00-3MN

EAR99

2/66

3WL91 11-0AB18

1/39

1/40

3VL96 00-3MQ

EAR99

2/66

3WL91 11-0AD

3VL96 00-3MS

EAR99

2/66

3WL91 11-0AE

1/40

3VL96 00-4

EAR99

2/73, 2/81

3WL91 11-0AF

1/40

1/40

3VL96 00-8B

EAR99

2/86, 2/95

3WL91 11-0AG

3VL96 00-8CA

EAR99

2/80 ... 81

3WL91 11-0AH

1/38

3VL96 00-8CB

EAR99

2/80 ... 81

3WL91 11-0AJ

1/38

1/34 ... 35

3VL96 00-8CE

2/79 ... 81

3WL91 11-0AK

3VL96 00-8L

EAR99

2/86 ... 87

3WL91 11-0AL

1/45

3VL96 00-8S

EAR99

2/87

3WL91 11-0AM0

1/45

1/47

3VL96 8

2/90

3WL91 11-0AM9

3VL97 0

EAR99

2/81, 2/84 ... 88

3WL91 11-0AN0

1/46

3VL97 1

EAR99

2/83 ... 88, 2/90

3WL91 11-0AN1

1/46

1/46

3VL98 00-1S

2/60

3WL91 11-0AN2

3VL98 00-1UD

2/60

3WL91 11-0AN3

1/46

3VL98 00-1UG

2/60

3WL91 11-0AN4

1/46

1/41

3VL98 00-1UH

2/60

3WL91 11-0AP

3VL98 00-1UJ

2/60

3WL91 11-0AR

1/41

3VL98 00-1UK

EAR99

2/60

3WL91 11-0AS

1/41

3WL91 11-0AT

1/34 ... 35, 1/37, 1/43 ... 44,


2/98

3WL91 11-0BA0

1/42

3WL91 11-0BA10

1/42

3WL91 11-0BA14

1/37, 2/59 ... 60

3WL91 11-0BA2

1/35

3WL91 11-0BA3

1/35

3WL91 11-0BA4

1/35

3WL91 11-0BA5

1/35

3WL91 11-0BA7

1/35, 1/38

3WL91 11-0BA8

1/35 ... 36

3WL91 11-0BB1

1/36

3WL91 11-0BB2

1/36

3WL91 11-0BB3

1/36

3WL91 11-0BB4

1/36

3WL91 11-0BB5

1/42

3WL91 11-0BB6

1/43

3WL91 11-0BC

1/43, 1/47, 2/98

3WL91 11-0BD

1/48

2/61

3WL91 12

1/36

2/90

3WL92

1/30 ... 33, 1/53 ... 54

3VL98 00-1UL

2/60

3VL98 00-1UM

2/60

3VL98 00-1UN

2/60

3VL98 00-1UP

2/60

3VL98 00-1UQ

2/60

3VL98 00-1UR

2/60

3VL98 00-1US

2/60

3VL98 00-1UU

2/60

3VL98 00-1UV

2/60

3VL98 00-2

EAR99

2/60

3VL98 00-3AS

2/65

3VL98 00-3AT

2/65

3VL98 00-3AU

EAR99

2/65

3VL98 00-3AW

EAR99

2/65

3VL98 00-3H

EAR99

2/65, 2/87 ... 88

3VL98 00-3M

2/66

3VL98 00-4

EAR99

2/74 ... 75, 2/81 ... 82

3VL98 00-8

EAR99

2/81 ... 82, 2/87 ... 88,


2/96 ... 97

3VL98 16-2
3VL98 16-8

20

Export markings

20/46

EAR99
N

N
N

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

3WL93

Export markings
ECCN

AL

Page

Order No.

ECCN

AL

1/34

5SH2

5/16, 10/31

5SH30

5/16, 10/31

3ZS

Export markings

Page

3ZS23

1/43, 2/98, 13/19

5SH31

5/16

3ZS27 10

EAR99S

13/18

5SH32 0

5/16

3ZS27 11

EAR99S

13/18

5SH32 1

5/16

3ZS27 12-0CC20-0YA

5D992

13/18

5SH32 2

5/16

3ZS27 12-0CC20-0YD

EAR99S

13/18

5SH32 8

5/16

3ZS27 13

EAR99S

13/18

5SH33

5/16 ... 17

3ZS27 14

EAR99S

13/18

5SH34

5/17

3ZS27 81

On req.

13/13

5SH35

3ZS27 82

5D992

13/14

5/31, 10/10 ... 11,


10/13 ... 14

3ZS27 85

EAR99S

13/10

5SH37

5/16

3ZS27 91

On req.

13/15

5SH4

5/11

3ZS27 95

EAR99S

13/12

5SH50

5/11

13/18

5SH51

5/11

5SH52

5/10, 10/30

9/4, 9/6, 9/8, 12/30

5SH53

5/30 ... 31

5/11

3ZS28

5D992

N
N

4AC, 4AT, 4NC


4AC

4AT

12/27

5SH54

4NC

2/92 ... 93

5SH55 0

5/11

5SH55 1

5/30

5SA, 5SB, 5SC, 5SD


5SA

5/13

5SH55 25

10/32

5SB

5/13

5SH55 26

10/32

5SC

5/13

5SH55 27

5/8, 10/32

5SD4

5/62

5SH55 3

5/8

5SD5

5/62

5SJ, 5SK, 5SL, 5SM

5SD6

5/14

5SJ

3/25, 3/48 ... 52

3/59

5SD74 1

6/4, 6/12

5SK

5SD74 2

6/10, 6/12

5SL

3/6 ... 7

5SD74 3

6/11 ... 12

5SM1

4/14, 4/26

3/32 ... 33, 4/16 ... 17

5SD74 41

6/6

5SM2

5SD74 42

6/6

5SM31

4/6

5SD74 43

6/6

5SM33 1

4/5 ... 8

EAR99H

4/10

5SD74 44

6/6

5SM33 2

5SD74 48

6/12

5SM33 42-0

4/5

5SD74 6

6/9, 6/12

5SM33 42-4

EAR99H

4/10 ... 11

4/6 ... 8

5SD74 7

6/10

5SM33 42-6

5SD74 8

6/9 ... 10, 6/12

5SM33 44-0

4/5

5SD74 9

6/12 ... 13

5SM33 44-4

EAR99H

4/10 ... 11

5SD75

6/17

5SM33 44-6

4/6 ... 8

5SD8

5/13

5SM33 45

4/5 ... 6

5SM33 46-0

4/5

5SE, 5SF, 5SG, 5SH


5SE

5/7, 5/62

5SM33 46-4

EAR99H

4/10 ... 11

5SF

5/14 ... 15, 10/30 ... 31

5SM33 46-6

4/6 ... 8

5SG1

5/9

5SM33 47-4

EAR99H

4/10 ... 11

5SG5

5/9 ... 10

5SM33 47-6

4/6 ... 7

5SG6

10/30

5SM33 48

4/6

5SG71 1

5/8

5SM33 5

4/7

5SG71 2

5/8

5SM34

4/5 ... 6, 4/8

5SG71 3

5/8

5SM36 1

4/6, 4/8

5SG71 5

5/8

5SM36 2

EAR99H

4/10

5SG71 6

5/8

5SM36 42-0

4/5

5SG72

10/31

5SM36 42-4

EAR99H

4/10 ... 11

5SG76

5/8

5SM36 42-6

4/6 ... 7

5SH11 1

5/15

5SM36 44-0

4/5

5SH11 2

5/15

5SM36 44-4

EAR99H

4/10 ... 11

5SH11 3

5/15

5SM36 44-6

4/6 ... 8

5SH11 4

5/15

5SM36 44-8

4/8

5SH11 6

5/15

5SM36 45

4/5 ... 6, 4/8

5SH11 7

5/15

5SM36 46-0

4/5

5SH12

5/15

5SM36 46-4

EAR99H

4/10 ... 11

Siemens LV 10.1 2011

20/47

20

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

Export markings

Page

Order No.

Page

ECCN

AL

ECCN

AL

5SM36 46-5

EAR99H

4/10

5ST37 50

3/41, 4/25, 5/30

5SM36 46-5K

4/11

5ST37 50-0

3/45, 5/32

5SM36 46-6

4/6 ... 8

5ST37 6

3/28, 3/42

5SM36 46-8

4/8

5ST37 7

3/41, 3/45, 4/25, 5/32

5SM36 47-4

EAR99H

4/10 ... 11

5ST38 00

3/34, 8/19

5SM36 47-5

EAR99H

4/10

5ST38 01

3/34, 3/53, 8/7, 8/19

5SM36 47-5K

4/11

5ST38 02

3/34, 3/53, 4/14

5SM36 47-6

4/6 ... 8

5ST38 03

3/34

5SM36 48

4/6, 4/8

5ST38 05

4/22

5SM36 5

4/7

5ST38 06

3/34

5SM37 42

4/6

5ST38 07

3/34

5SM37 44

4/6

5SU, 5SV, 5SW, 5SY, 5SZ

5SM37 45

4/5 ...6, 4/8

5SU

4/11 ... 12, 4/19 ... 22

5SM37 46-4

EAR99H

4/10

5SV

12/10

5SM37 46-5

EAR99H

4/10

5SW1

3/35, 4/27

5SM37 46-6

4/6 ... 7

5SW30

3/35, 4/14, 4/27

5SM37 47-4

EAR99H

4/10

5SW33 00

4/14

5SM37 47-5

EAR99H

4/10

5SW33 01

4/14

5SM37 48

4/6

5SW33 02

4/14

5SM38

4/8

5SW33 03

4/14

5SW33 1

4/14, 4/27

5SP, 5ST
5SP

3/15 ... 16, 3/56 ... 57

5SW33 3

4/14

5ST13

3/57

5SY4

3/11 ... 14

5ST18

3/59

5SY5

3/16 ... 17

5ST21 34

3/35, 4/27

5SY6

3/28

5ST21 35

3/35, 4/27

5SY7

3/18 ... 20

5ST21 36

3/35, 4/27

5SY8

3/21 ... 22

5ST21 4

4/25

5SZ

4/26

5ST21 56

4/25

5TE, 5TG, 5TT

5ST21 57

4/25, 5/31

5TE1

7/27

5ST21 7

3/34, 4/27

5TE2

8/20

5ST21 8

5/30

5TE4

8/10 ... 11

5ST21 90

5/30

5TE5

8/13

5ST21 91

5/30

5TE6

9/10 ... 11

5ST21 92

5/30

5TE8

8/6, 8/17 ... 18

5ST21 96

5/30

5TE9

7/28, 8/19, 8/23, 9/11

5ST21 97

5/30

5TG

5ST22

3/34, 4/27

3/34, 8/7, 8/11, 8/14, 8/19,


8/29, 8/32, 12/34 ... 35

5ST26

5/24

5TT1

8/50

5TT3

5/43, 8/37, 8/51,


12/13 ... 14, 12/18 ... 20,
12/27, 12/31, 12/34 ... 35,
12/37, 12/40 ... 41

5ST30 1

3/31, 3/52, 5/8, 8/7, 8/18,


8/20

5ST30 2

3/31, 3/52

5ST30 3

3/31, 3/52

5TT41

8/26

5ST30 4

3/31

5TT42 0

8/29

5ST30 5

3/31, 4/14

5TT42 1

8/29

5ST36

3/28, 3/39 ... 40, 3/45, 3/53,


4/24 ... 25, 5/31 ... 32

5TT49

8/27

5TT5

8/32, 8/35 ... 36, 12/32

3/41, 3/45, 4/24,


5/29 ... 30, 5/32

5TT6

12/16 ... 17

5TT7

12/30

5ST37 0

20

Export markings

5ST37 1

3/41, 3/45, 4/24 ... 25,


5/29 ... 30, 5/32

5ST37 3

3/40, 4/24

7KM2

5D992

11/27

5ST37 40

3/40

7KM3

EAR99APP N

11/26

5ST37 41

3/40

7KM4

5D992

11/28

5ST37 42

3/40

7KM92

EAR99H

11/31

5ST37 43

3/40

7KM93

11/29 ... 30

5ST37 44

3/40

7KM99

11/26 ... 28

5ST37 45

3/40

7KT

5ST37 46

3/40

7KT10 0

11/32

5ST37 48

3/41, 5/30

7KT10 10

11/32

5ST37 48-0

3/45, 5/32

7KT10 11

11/32

20/48

Siemens LV 10.1 2011

7KM

Siemens AG 2011

Appendix
Order number index
incl. export markings
Order No.

Export markings

Page

Order No.

ECCN

AL

8UC6

2/67, 7/40 ... 42, 7/48 ... 50,


7/55 ... 56, 7/62

8UC7

2/67, 2/69, 7/34, 7/36, 7/38,


7/40 ... 42, 7/46,
7/48 ... 50, 7/54 ... 56,
7/61 ... 62

8UC9

7/36 ... 38, 7/41 ... 42, 7/46,


7/50, 7/62 ... 63

8US10

2/89

8US12 0

10/14

8US12 1

2/90, 7/117, 10/18 ... 21

8US12 50

10/16 ... 17, 10/20 ... 22

8US12 51-5DS10

5/24, 10/16, 10/21

8US12 51-5DS11

On req.

8US12 51-5DT

5/24, 10/16, 10/21

8US12 51-5N

10/17, 10/21

8US12 6

10/18, 10/22

8US12 9

7/117

8US19 0

10/7

8US19 21-1

10/14

8US19 21-2AA

10/15

8US19 21-2AB

10/15

8US19 21-2AC

10/15

8US19 21-2AD00

10/15

8US19 21-2AD01

10/15

8US19 21-2BA

10/15

8US19 21-2BB

10/15

8US19 21-2BC

10/15

8US19 21-2BD00

10/15

8US19 21-2BD01

10/15

8US19 21-2BE

10/12, 10/24 ... 25

8US19 21-2BF

10/12, 10/24 ... 25

8US19 22

10/7, 10/11 ... 13, 10/15

8US19 23

10/10 ... 11

8US19 27

2/90, 10/19

8US19 41-2AA01

10/15

8US19 41-2AA02

10/15

8US19 41-2AA03

10/14

8US19 41-2AA04

10/15

8US19 41-2AC

10/15

8US19 41-2B

10/13, 10/15

8US19 43

10/13

8US19 48

10/13

8US19 98-1AA0

10/18, 10/22, 10/25

8US19 98-1AA1

10/24

8US19 98-1BA0

10/25

8US19 98-1BA1

10/24

8US19 98-1CA0

10/25

8US19 98-1CA1

10/24

8US19 98-1D

10/25

8US19 98-2

10/22

8US19 98-4

10/25

8US19 98-7

5/24, 10/24 ... 25

8WC

10/7, 10/12

--N

7/88

ECCN

AL

7KT10 12

11/32

7KT10 2

11/32

7KT11 1

11/34

7KT11 2

11/34

7KT11 4

11/11

7KT12

11/39

7KT13 0

11/16

7KT13 1

11/19

7KT13 4

11/19

7KT13 9

11/22

7KT15

11/8, 11/11

7KT19

11/13

7KT55

11/38

7KT56

11/38

7KT58 0

11/36

7KT58 1

11/36

7KT58 2

11/36

7KT58 3

11/36

7KT90 0

9I999

11/38

7KT90 10

11/40

7KT90 11

11/40

7KT90 2

11/38

7LF, 7LQ
7LF4

8/40 ... 41

7LF5

8/47

7LF61 10

8/50

7LF61 11

8/50

7LF61 12

8/50

7LF61 13

8/50

7LF61 14

8/50

7LF61 15

8/50

7LF61 16

8/50

7LF9

3/35, 8/41, 8/48

7LQ20

12/39

7LQ21 00

12/37

7LQ21 01

12/37

7LQ21 02

12/37

7LQ21 03

12/37

7LQ22

9/9

7LQ29

12/37, 12/39

7LQ33 5

12/26 ... 27

7LQ33 60

12/27

7LQ33 61

12/26

7LQ33 62

12/26

8GB, 8GK
8GB

3/35

8GK4

10/9

8GK97 1

10/10

8GK97 3

10/12

8HP, 8JH, 8JK


8HP27 0

7/39

8HP27 1

7/39

8HP27 3

7/39

8HP27 4

7/39

8HP27 5

7/39

8HP27 6

7/39

8JH

5/31

8JK

10/12

7/37 ... 38

Export markings

Page

8US, 8WC

10/16, 10/21

XP
XPT

8UB, 8UC
8UB

Siemens LV 10.1 2011

20/49

20

Siemens AG 2011

Appendix
Notes

20

20/50

Siemens LV 10.1 2011

Siemens AG 2011

Appendix
Notes

Siemens LV 10.1 2011

20/51

20

Siemens AG 2011

Appendix
Terms and conditions of sale and delivery

Overview
By using this catalog you can acquire hardware and software
products described therein from Siemens AG subject to the following terms. Please note! The scope, the quality and the conditions for supplies and services, including software products, by
any Siemens entity/regional having a registered office outside of
Germany, shall be subject exclusively to the General Terms and
Conditions of the respective Siemens entity. The following terms
apply exclusively for orders placed with Siemens AG.
For customers with a seat or registered office in Germany
The General Terms of Payment as well as the General Conditions
for the Supply of Products and Services of the Electrical and
Electronics Industry shall apply.
For software products, the General License Conditions for Software Products for Automation and Drives for Customers with a
Seat or Registered Office in Germany shall apply.
For customers with a seat or registered office outside of
Germany
The General Terms of Payment as well as the General Conditions
for Supplies of Siemens Automation and Drives for Customers
with a Seat or registered Office outside of Germany shall apply.
For software products, the General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or registered Office outside of Germany shall apply.

Export regulations
Our obligation to fulfill this agreement is subject to the proviso
that the fulfillment is not prevented by any impediments arising
out of national and international foreign trade and customs requirements or any embargos and/or other sanctions.
If you transfer goods (hardware and/ or software and/ or technology as well as corresponding documentation, regardless of the
mode of provision) delivered by us or works and services (including all kinds of technical support) performed by us to a third
party worldwide, you shall comply with all applicable national
and international (re-) export control regulations.
If required to conduct export control checks, you, upon request
by us, shall promptly provide us with all information pertaining to
particular end customer, destination and intended use of goods,
works and services provided by us, as well as any export control
restrictions existing.
The products listed in this catalog / price list may be subject to
European / German and/or US export regulations.
Therefore, any export requiring a license is subject to approval
by the competent authorities.
According to current provisions, the following export regulations
must be observed with respect to the products featured in this
catalog / price list:

General
All dimensions are in mm. In Germany, according to the German
law on units in measuring technology, data in inches only apply
to devices for export.

AL

Products marked other than "N" require an export license.


In the case of software products, the export designations of the
relevant data medium must also be generally adhered to.

Illustrations are not binding.


Insofar as there are no remarks on the corresponding pages,
- especially with regard to data, dimensions and weights given these are subject to change without prior notice.
The prices are in (Euro) ex works, excluding packaging.
The sales tax (value added tax) is not included in the prices.
It shall be debited separately at the respective rate according to
the applicable legal regulations.
Prices are subject to change without prior notice. We will debit
the prices valid at the time of delivery.
Surcharges are added to the price of products that contain
silver, copper, aluminum, lead and/or gold if the respective basic
official prices for these metals are exceeded. These surcharges
will be determined based on the official price and the metal factor of the respective product.
The surcharge will be calculated on the basis of the official price
on the day prior to receipt of the order or prior to the release
order.
The metal factor determines the official price as of which the
metal surcharges are charged and the calculation method used.
The metal factor, provided it is relevant, is included with the price
information of the respective products.
An exact explanation of the metal factor and the text of the
Comprehensive Terms and Conditions of Sale and Delivery are
available free of charge from your local Siemens business office
under the following Order Nos.:
6ZB5310-0KR30-0BA1
(for customers based in Germany)
6ZB5310-0KS53-0BA1
(for customers based outside Germany)
or download them from the Internet:
www.siemens.com/industrymall
(Germany: Industry Mall Online Help System)

20

20/52

Siemens LV 10.1 2011

Number of the German Export List

Goods labeled with an "AL" not equal to "N" are subject to a


European or German export authorization when being
exported out of the EU.
ECCN

Export Control Classification Number


Products marked other than "N" are subject to a re-export
license to specific countries.
In the case of software products, the export designations of the
relevant data medium must also be generally adhered to.
Goods labeled with "ECCN" not equal to "N" are subject to a US
re-export authorization.

Even without a label or with an "AL: N" or "ECCN: N", authorization may be required due to the final destination and purpose for
which the goods are to be used.
The deciding factors are the AL or ECCN export authorization
indicated on order confirmations, delivery notes and invoices.
Errors excepted and subject to change without prior notice.

Siemens AG 2011

Catalogs
Industry Automation, Drive Technologies and Low Voltage Distribution
Further information can be obtained from our branch offices listed
in the appendix or at www.siemens.com/automation/partner
Interactive Catalog on DVD
for Industry Automation, Drive Technologies and
Low Voltage Distribution

Catalog
CA 01

Low-Voltage Power Distribution and


Electrical Installation Technology

Catalog

Protection, Switching, Measuring & Monitoring Devices LV 10.1

Drive Systems
Variable-Speed Drives
SINAMICS G110, SINAMICS G120
Standard Inverters
SINAMICS G110D, SINAMICS G120D
Distributed Inverters

D 11.1

SINAMICS G130 Drive Converter Chassis Units


SINAMICS G150 Drive Converter Cabinet Units

D 11

SINAMICS GM150, SINAMICS SM150


Medium-Voltage Converters

Switchboards and Distribution Systems

LV 10.2

GAMMA Building Management Systems

ET G1

PDF: DELTA Switches and Socket Outlets

ET D1

SICUBE System Cubicles and Cubicle Air-Conditioning LV 50


SIVACON 8PS Busbar Trunking Systems

LV 70

NC 60

D 12

Motion Control
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools

D 21.3

SINUMERIK & SINAMICS


Equipment for Machine Tools

NC 61

SINAMICS S120 Chassis Format Units and


Cabinet Modules
SINAMICS S150 Converter Cabinet Units

SIMOTION, SINAMICS S120 and


Motors for Production Machines

PM 21

SINAMICS DCM Converter Units

D 23.1
D 84.1

SINAMICS S110
The Basic Positioning Drive

PM 22

Three-phase Induction Motors


H-compact
H-compact PLUS
Asynchronous Motors Standardline

D 86.1

Power Supply and System Cabling


Power supply SITOP

KT 10.1

Synchronous Motors with Permanent-Magnet


Technology, HT-direct

D 86.2

System cabling SIMATIC TOP connect

KT 10.2

DC Motors

DA 12

SIMOREG DC MASTER 6RA70 Digital Chassis


Converters

DA 21.1

Process Instrumentation and Analytics


Field Instruments for Process Automation

FI 01

SIREC Recorders and Accessories

MP 20

SIMOREG K 6RA22 Analog Chassis Converters

DA 21.2

SIPART, Controllers and Software

MP 31

PDF: SIMOREG DC MASTER 6RM70 Digital Converter


Cabinet Units

DA 22

Products for Weighing Technology

WT 10

SIMOVERT PM Modular Converter Systems

DA 45

SIEMOSYN Motors

DA 48

MICROMASTER 420/430/440 Inverters

DA 51.2

MICROMASTER 411/COMBIMASTER 411

DA 51.3

SIMOVERT MASTERDRIVES Vector Control

DA 65.10

SIMOVERT MASTERDRIVES Motion Control

DA 65.11

Synchronous and asynchronous servomotors for


SIMOVERT MASTERDRIVES

DA 65.3

SIMODRIVE 611 universal and POSMO

DA 65.4

SIMOTION, SINAMICS S120 and


Motors for Production Machines

PM 21

SINAMICS S110
The Basic Positioning Drive

PM 22

Low-Voltage Three-Phase-Motors

PDF: Process Analytical Instruments

PA 01

PDF: Process Analytics,


Components for the System Integration

PA 11

Safety Integrated
Safety Technology for Factory Automation

SI 10

SIMATIC HMI/PC-based Automation


Human Machine Interface Systems/
PC-based Automation

ST 80/
ST PC

SIMATIC Industrial Automation Systems


Products for Totally Integrated Automation and
Micro Automation

ST 70

SIMATIC PCS 7 Process Control System

ST PCS 7

Add-ons for the SIMATIC PCS 7


Process Control System

ST PCS 7.1
ST PCS 7.2

IEC Squirrel-Cage Motors

D 81.1

MOTOX Geared Motors

D 87.1

Automation Systems for Machine Tools SIMODRIVE


Motors
Converter Systems SIMODRIVE 611/POSMO

NC 60

PDF: Migration solutions with the SIMATIC PCS 7


Process Control System

Automation Systems for Machine Tools SINAMICS


Motors
Drive System SINAMICS S120

NC 61

SIMATIC NET
Industrial Communication

IK PI

Drive and Control Components for Hoisting Equipment

HE 1

SIMATIC Sensors
Sensor Technology for Factory Automation

FS 10

Industrial Identification Systems

ID 10

Mechanical Driving Machines


Flender Standard Couplings
Industrial Controls
SIRIUS Industrial Controls

MD 10.1

IC 10

System Solutions
Applications and Products for Industry are part of the
interactive catalog CA 01

Download-Center
PDF: These catalogs are only available as pdf files.

PDF versions of the catalogs are available on the Internet at:


www.siemens.com/automation/infocenter

Siemens AG 2011

Siemens AG
Industry Sector
Building Technologies Division
Low Voltage Distribution
Postfach 10 09 53
93009 REGENSBURG
GERMANY
Subject to change without prior notice
Order No. E86060-K8250-A101-A1-7600
3P.8303.51.02 / Dispo 18301
KG 1210 10. ST 712 En
Printed in Germany
Siemens AG 2010
The information provided in this catalog contains descriptions or
characteristics of performance which in case of actual use do not
always apply as described or which may change as a result of further
development of the products. An obligation to provide
the respective characteristics shall only exist if expressly agreed in the
terms of contract. Availability and technical specifications are subject
to change without notice.
All product designations may be trademarks or product names
of Siemens AG or supplier companies whose use by third
parties for their own purposes could violate the rights of
the owners.

Token fee: 10.00

www.siemens.com/lowvoltage

You might also like