You are on page 1of 2

Category 6A

U/UTP 4 Pair Cable


Norden Category 6A U/UTP cables exceed Category 6A/Class EA
specification. It is tested to 500MHz frequency range and designed to
support 10 Gigabyte applications to full 100m.
Extremely high pair-balance providing excellent EMC (Electro Magnetic
compatibility), minimizing radiation, maximizing noise immunity and
providing high alien cross talk performance to U/UTP (Unshielded
Twisted Pair) cabling systems.

1
2
3
4

Outer Jacket

Insulation

Center Conductor

Seperartor

Rip Cord

COMPLIANCE
IEEE 802.3an :2006 (10GBASE-T)
ANSI/TIA-568-C.2:2009 Category 6A
ISO/IEC-11801, 2nd Edition Class EA
IEC 61156-5:2002 Category 6A
LSZH: IEC 60332-1, IEC 60754, IEC 61034

NORDEN PRODUCT CATALOGUE

DATA CABLES

MATERIAL CONSTRUCTION & DESIGN


Conductor Material:
Conductor Size:
Conductor Construction:
Insulation Material:
Insulation O.D.:
Conductor Unit Identification:
Colour Code:
Conductor Unit Lay-Up:
Total Number of Wires:
Outer Jacket Material:
Outer jacket thickness & Ex. Diameter:
Outer Jacket Colour:
Rip Cord:
Overall Drain-Wire Material:
Overall Drain-Wire Construction:

Bare Copper
0.57mm (D) norm, 23 AWG
Solid
HDPE
1.03 mm nom.
Solid/Stripe
Per TIA/EIA 568-B
Pairs
8
PVC, LSZH and Plenum
0.650.05mm, 6.90.4mm
Per requirement
Yes
N/A
N/A

Category 6A
U/UTP 4 Pair Cable
MECHANICAL, ELECTRICAL & TRANSMISSION CHARACTERISTICS
Pulling Force:
Delay Skew:
Coupling Attenuation:
Characteristic Impedance:
DC Resistance:
Resistance Unbalance:
Capacitance:
Cap. Unbalance (Wire to Ground):
Dielectric Strength:
Velocity of Propagation (NVP):
Insulation Resistance:
Transfer Impedance:
Short Term Bend Radius :
Long Term Bend Radius :
Temperature Operating Range :
Installation Temperature Range :

110 N/mm2 max.


25ns/100m max.
85 db min @ 30-100 MHz 85-20log(f/100) @100-500 MHz
1006 @ 1-500 MHz
72/Km max.
2% max.
45 pF/m nom.
1500 pF/Km max.
1.5KV/ minute min.
67%
5000 MKm min.
N/A
8 x OD mm
4 x OD mm
-20 to +60C
0 to +50C

ELECTRICAL PERFORMANCE CHARACTERISTICS


Cat. 6A Un-screened Pair Horizontal Cables*
Freq.
MHz
1
4
10
20
31.25
100
150
200
250
300
400
500

Attenuation
dB/100m@20C
1.7
3.4
5.4
7.6
9.7
18.0
23.6
27.4
31.0
34.2
40.0
42.2

NEXT
dB
86.3
85.0
77.3
70.0
68.0
65.3
62.0
59.0
57.6
55.0
53.0
52.0

PS NEXT
dB
83.3
83.0
74.3
67.0
65.0
62.3
59.8
57.2
54.6
52.0
51.8
50.0

RL
dB
26.0
29.0
31.0
30.0
29.8
27.1
26.0
25.0
25.2
24.0
21.8
21.8

ACR
dB
84.6
75.6
71.9
62.4
58.3
47.3
38.4
31.6
26.6
20.3
13.0
9.8

ELFEXT
dB
84.0
81.0
76.0
70.0
65.0
55.0
53.5
49.0
44.0
39.6
37.0
35.0

PSELFEXT
dB
80.0
78.0
73.0
67.0
63.0
52.8
51.5
46.0
41.0
36.6
34.0
33.0

*Supplied cables meet the minimum Cat. 6A transmission requirements as per IEC 61156-5 Ed. 2

ORDERING INFORMATION

305 mtr.
305 mtr.

LENGTH (STANDARD)

114-15004104X

Category 6a U/UTP 4 Pair Cable Plenum

305 mtr.
X:BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)

PACKING INFORMATION
Cable Length
(Metre)
305
1000

Packing Mode
Ply Reel
Ply Reel

www.nordencommunication.com

N.W
(kg)
15.0
49.3

G.W
(kg)
16.8
55.6

Dimension
(cm)
34.0 x 34.0 x 34.0
56.0 x 56.0 x 25.0

DATA CABLES

DESCRIPTION
Category 6a U/UTP 4 Pair Cable PVC
Category 6a U/UTP 4 Pair Cable LSZH

NORDEN PRODUCT CATALOGUE

PART NUMBER
114-10001104X
114-10002104X

You might also like