You are on page 1of 21
2x600 MW Long Phu 1 EPC RFP Document VOLUME : II-H SECTION-II TECHNICAL SPECIFICATION FOR HORIZONTAL CENTRIFUGAL PUMPS (11-201 R-GSPC-2710-V2H SECIAoe) 2x600 MW Long Phu 4 - EPC RFP Document VOLUME : IL-H SECTION-I TECHNICAL SPECIFICATION FOR HORIZONTAL CENTRIFUGAL PUMPS: TABLE OF CONTENT CLAUSE NO. DESCRIPTION 1.00.00 GENERAL INFORMATION 2.00.00 CODES AND STANDARDS 3.00.00 SCOPE OF WORKS 4.00.00 PERFORMANCE REQUIREMENTS 5.00.00 DESIGN AND CONSTRUCTION 8.00.00 INSPECTION AND TESTING 7.00.00 DRAWINGS, DATA, CURVES AND INFORMATION, ATTACHMENT ANNEXURE-1 TECHNICAL DATASHEET FOR CCCW PUMPS ANNEXURE-II TECHNICAL DATASHEET FOR ACW PUMPS, ANNEXURE-III TECHNICAL DATASHEET FOR RW FORWARDING PUMPS ANNEXURE-IV TECHNICAL DATASHEET FOR PT SYSTEM FEED PUMPS ANNEXURE-V TECHNICAL DATASHEET FOR FILTERED WATER PUMPS ANNEXUREVI TECHNICAL DATASHEET FOR DM TRANSFER PUMPS: ANNEXURE-VIl_ TECHNICAL DATASHEET FOR FRESH WATER TRANSFER PUMPS ANNEXURE-VII_ TECHNICAL DATASHEET FOR POTABLE WATER PUMPS. ANNEXURE-IX TECHNICAL DATASHEET FOR CONDENSATE TRANSFER PUMPS (2010-6 SPO-2210-V2H SECT AOF) 2x600 MW Long Phu 1 - EPC RFP Document 1.00.00 1.01.00 2.00.00 2.01.00 2.01.01 2.01.02 2.01.03 2.01.04 2.01.05 2.01.06 2.01.07 2.01.08 2.01.09 2.01.10 2.02.00 SECTION-1 TECHNICAL SPECIFICATION FOR HORIZONTAL CENTRIFUGAL PUMPS GENERAL INFORMATION This section presents the general guidelines and details of horizontal centrifugal pumps to be procured under the scope of this saction and shall not be limited to the pumps specified under clause no. 3.00.00 below. For other horizontal centrifugal pumps in the scope of this specification, these general guidelines as specified hereinafter shall be followed CODES AND STANDARDS ‘The design, manufacture and performance of the horizontal centrifugal pumps as specified hereinafter, shall comply with the requirements of the following codes and standards and shall include all the latest amendments subsequent to the year of publication as mentioned below. Hydraulic Institute Standards API-610: Centrifugal pumps for general refinery services PTC-6.2: Power Test Codes — Centifugal Pumps 10-2858: End suction centrifugal pumps (rating 16 bar) — designation, nominal duty point and dimension. 180-3069: End suction centrifugal pumps — dimensions of cavities for mechanical seals and for soft packing. 180-3665: Centrifugal, mixed flow and axial pumps — codes for acceptance test, Class B. 1S0-2648: Centrifugal, mixed flow and axial pumps ~ codes for acceptance test, Ciass C. 180-3661: End suction centrifugal pumps - base plate end installation dimensions. ANS! Standards on flanges ‘The materials of various components shall conform to the applicable ASTM. Standards or approved equipment. In case of any contradiction with the above standards and annexuras, the stipulations in the annoxures shall prevail and shall be binding to the Contractor. (1201-6 SPC zz10-vEHSECAIAOG) Page: vaHs2n 2x600 MW Long Phu 4 EPC RFP Document 3.00.00 SCOPE OF WORKS 3.01.00 ‘Scope of Supply The scope of supply under this section shall be as below. Items specifically not mentioned but deemed necessary by the Tenderer for making the system completely reliable and effi t shall also be included. 301.01 Equipment a) Two (2) x 100% Closed Cycle Cooling Water Pumps along with Motors and accessories, common for two (2) units. b) Two 2) x 100% Auxiliary Cooling Water Pumps along with Motors and accessories for each of the two (2) units. © Four (4) x 50% Raw Water Forwarding Pumps along with Motors and ‘accessories, common for two (2) units. 4) Two (2) x 100% Pre-treatment System Feed Pumps along with Motors and accessories, common for two (2) units. ©) Two (2) » 100% Filtered Water Pumps along with Motors and accessories, common for two (2) units. f) Two (2) « 100% DM Transfer Pumps along with Motors and accessories, common for two (2) units. @) Two (2) x 100% Fresh Water Transfer Pumps along with Motors and accessories, common for two (2) units. h) Two (2) = 100% Potable Water Pumps along with Motors and ‘accessories, common for two (2) units. i) Two (2) x 100% Condensate Transfer Pumps along with Motors and accessories for each of the two (2) uni. 3.01.02 Equipment Accessories Each pump set for all the above groups shall be supplied with the following accessories: a) Sets of base plates, support plates, grounding pads, lifting lugs, eye bolts, nuts ete. b) Foundation bolts, nuts, sieeves ete. ©] Slip-on type drilled siee! flanges of proper rating for both suction and ischarge connections. All the counter-flanges shall be complete with requisite number of bolts, nuts, gaskets etc. d) Unions for external water connection for cooling and sealing / lubrication. (1201046 5PC-2210.V2H SEGAL G07) Page: Vaaszr2 2x600 MW Long Phu 1 EPC RFP Document 3.02.00 4.00.00 4.01.00 4.02.00 4.03.00 4.04.00 4.05.00 4.06.00 4.07.00 ©) Complete cooling! sealing/ lubrication system with all accessories, pipes, valves and with all instruments f) Discharge line pressure gauge and suction line pressure/vacuum gauges complete with isolating cocks. 9) Drain and vent connection with vaive. h) Pump motor coupling and guard, i) Motor slide rail and foundation bolts, i) Bearing temperature gauge with electrical contacts for all pumps and motors rated 160 KW and above. For details regarding scope of services and works Volume IIA of this specification shall be referred to. PERFORMANCE REQUIREMENTS Performance requirements for the pumps shall be as guided in Section-| of this volume and by the Annexures enclosed with this section. Each pump shall be of horizontal, single or muttistege, centrifugal type and constructed of materials suitable for operation and resistant to corrosion or ‘erosion by the fluid pumped Pumps shall preferably be designed to have the best efficiency at the specified duty point. The pumps shall be suitable for continuous operation at any point within the "Range of Operation" Pumps shall preferably have a continuously rising head-capacity characteristics from the specified duty point towards shutoff point, the maximum being at shut-off to enable parallel operation, Under all circumstances, the ‘range of operation’ of the pumps shall exclude any unstable operating zone of the head - capacity curve. ‘Wherever specified in the annexures attached to this section, pumps of each category shall be suitable for parallel operation. The head vs. capacity, the BHP vs. capacity characteristics etc. shail be identical to ensure equal load shering and trouble-free operation of eny pump when the other pumps working in parallel with it trip. The pump motor sets shall be designed in such a way that there is no damage due to the reverse flow through the pump which may occur due to any mal-operation/ working condition of the system. When start-up under reverse flow through the pump is specified in the specification data sheets, the crive motor shall be capable of bringing the Pump to its rated speed in the normal direction from the point of maximum possible reverse speed, (11:20104-6-SPC-2210.V2H SECA C08) Page: V2HS2 2x600 MW Long Phu 1 EPC RFP Document 4.08.00 4.09.00 4.40.00 5.00.00 5.01.00 5.01.01 5.01.02 5.01.03 5.01.04 5.01.05 5.02.00 5.02.01 5.02.02 5.02.03 ‘The pump set along with the drive motor shall run smooth without undue noise, vibration, cavitation and leaks throughout the complete range of operation. Acceptable peak fo peak viration limits shall be generally guided by the Hydraulic Institute Standards, ‘The design and workmanship of the component paris of each pump shall be such that they are completely interchangeable with like parts of other pumps 80 as to promote the interchangeability of parts between pumps. The contractor shall assume full responsibility in the operation of the pump and motor as one unit. DESIGN AND CONSTRUCTION Pump Casing Pump casing may be horizontally or vertically split or barrel type construction. The casing shall be designed to withstand the maximum shut-off pressure, or 115% of fated pumping pressure under which the pump can operate at cesign fluid temperature, whichever is higher. Pump casing shall be provided with adequate number of vents and priming connections with valves unless the pump is made self- venting and priming, Casing drain, as required, shall be provided complete with drain valves. Pump design must ensure that the nozzles are capable of withstanding extemal reactions not less than those specified in API-610. In cases where an expansion joint is located at pump discharge, the pump ascembly will be subjected to an additional thrust which will be tansmitted to the foundation. This additional thrust shall be taken into the consideration of pump design. For pumps working in series with other pumps end using an expansion joint at the suction. similar thrust at suction will be transrritted to the foundation for which the pump and foundation is to be adequately designed. Casing will be of such thickness as will be suitable for maximum cischarge and hydrostatic test pressure at pumping temperature, with a 32 mm minimum corrosion allowance. Impeller The impeller shall be secured to the shaft and shall be retained against circumferential movement by keying, pinning or lock rings. On pumps with over hung shaft, impellers shall be secured to the shaft by 2n additional locknut or cap screw. All screwed fasteners shall tighten in the direction of normal rotation, Impoliers shall be mede in one piece. Impeller shall be statically and dynamically balanced and designed with critical speed substantially above the operating speed (19-20104-6-5PC-22)05V2H-SECAL.G00) Page: V2aS2I¢ 2x600 MW Long Phu 4 EPC RFP Document 5.02.04 5.02.05 5.03.00 9.03.01 5.03.02 5.04.00 5.04.01 5.04.02 5.04.03, 5.05.00 5.05.01 5.05.02 5.06.00 5.06.01 5.06.02 5.06.03 Pumps shall not be furnished with maximum diameter impellers. Pumps shall be capable of at least 2 5% head increase at rated conditions by installing a new impeller. Impellers shall be enclosed and shall be accurately machined. Wearing Rings Replaceable type wearing rings shall be furnished to prevent damage to impeller and casing. Suitable method of locking the wearing ring shall be used. Wearing rings shall have a close tolerance fit to permit only a minimum of recirculation flow. Shaft Shaft shall be of ample size to transmit full driver output without excessive deflection, vioration, distortion or whip. Shaft size shall be selected considering that the critical speed shall be away from the operating speed as recommended in applicable Code/Standard. The critical speed shall also be at least 10% away from runaway speed. All the shaft surfaces shall be smoothly ground to accurate dimen Shaft Sleeves Renewable type fine finished sheft sleeves shall be provided at the stuting boxes/mechanical seals, Lenath of the sha't sleeves must extend beyond the other faces of gland packing or seal end plate so as to distinguish between the leakage past sheft and shaft sleeve and that past the sealsiglands. Shaft sleeves shall be proporiy fastened to the shaft to prevent any leakage or loosening, Shaft and shaft sleeve assembly should ensure concentric rotation Bearings Bearings shall be easily accessible without disturbing the pump assembiy. A drain plug shall be provided at the bottom of each of the bearing housing. Heavy duty sleeve/ball/roller type bearings shall be provided to take care of the radial loads. In case of sleeve type radial bearings, axial thrust shall be absorbed in suitable hydraulic devices andior thrust bearings. (11-20108-6-SPO-2210.V2H SEGALA0e) Page: V2HS215 2x600 NW Long Phu 1 EPC RFP Document 5.06.04 5.06.05 5.07.00 5.07.01 5.07.02 5.08.00 5.08.01 5.08.02 5.08.03 5.08.04 5.09.00 5.09.01 5.09.02 Bearings and hydraulic devices (if provided for balancing axial thrus') shall be of adequate design for taking the entire pump load arising from all probable conditions of continuous operation, as specified in the annexures. Life of the bearings shall be guided by the design standard of the pump or as specified in annexures. Thrust bearing shall be capable of running continuously at maximum load The bearings shall be oil/grease lubricated. Suitable lubricating arrangement for the bearings shall be furnished with the pump complete all accessories like pump, fiters, piping, fittings, valves, interlocking and supervising instruments etc. 2s necessary and specified in the Annexures. The design shall be such that the bearing lubricant does not contaminate the liquid being pumped. Stuffing Boxes Stufing box design shall permit replacement of packing without removing any part other than the gland. Stuffing boxes shall be sealed/cooled by the fluid being pumped/extemal clear water, as specified in the Annexures. Mechanical Seals Mechanical seals shall be provided if specified in the Annexures. The pump supplier shall co-ordinate with the seal maker in establishing the circulation rate for maintaining a stable film at the seal face in the chamber. The seal piping system shall form an integral part of the pump assembly. When handling liquids near their boiling point, suitable arrangement for extemal cooling shall be provided so as to prevent flashing at the seal faces. For the seals under vacuum service, the seal design must encure sealing against atmospheric pressure, even when the pumps are not operating, In the sealing inlet piping all pumps shall be provided with a suitable connection for connecting to an external water source. This external water ‘source shall be used for pump sealing during start-up only, if required. Shaft Couplings All direct driven pump shafts shall be connected with adequately sized gear couplings of suitable design Necessary coupling guard shall be provided for all pumps. It should meet OSHA requirement. (7201 0-6. SPC-2210.V2H SECA A05) Page: V2Hs2I6 2x600 MW Long Phu 1 EPC RFP Document 5.10.00 5.10.01 9.10.02 5.11.00 5.11.01 5.12.00 5.12.01 5.13.00 5.13.01 5.14.00 5.14.01 9.14.02 5.14.03 6.00.00 6.01.00 Base Plate & Sole Plate Unless otherwise stated in the specification data sheet, a common base plate mounting both for the pump and motor shall be furnished. The base plate shall be of rigid construction, suitably ribbed and reinforced. Base plate and pump supports shall be so constructed and pumping unit so mounted as to minimize miselignment caused by mechanical forces such as normal piping strain, internal differential thermal expansion and hydraulic piping thrust Suitable drain taps and drip lip shall be provided. required, steel sole plates shall be provided, below the base plate. Balancing All rotating components shall be statically and dynamically balanced at shop. Materials Meterials for the principal parts of pumps shall be as specified in data sheets. Where not specified, such materials shall be manufacturers standard, but suitable for the intended service. Materials must be specified by ASTM designations and standards. Painting, Packing, Handling For requirements of painting, stage inspection, detailed inspection and testing, packing, handling, instruction manual and all other particulars refer to various epplicable articles in General Technical Specification. Drive Unit Motors shall be selected in accordance with the driven equipment requirements, as indicated in the incividual equipment specifications. ‘The Tenderer shall be completely responsible for the selection and application of the motor drives, so that the driven equipment shall perform satisfactorily under the specified conditions. Motors shall be painted as per the manufacturer's standard. INSPECTION AND TESTING The Contractor shall carry out the following specific tests and inspections to ensure that the equipment furnished lies in strict conformance with the specification and also in accordance with applicable codes/standards and good engineering practice. @) Identification and Testing i) All materials used for pump construction shall be of tested quality. Material shall be tested as per tne relevant standards and test certificates shall be made available to the Owner. (1120104 SPC-22:0V2HSECA.G00) Page: V2iS27 2x600 MW Long Phu 1 EPC RFP Document ii) Tests for each pump included under this section shall include but not be limited to the following + The entire surface of the impeller castings shall be Subjected to Dye Penetration Test as per ASTM Specification no.: 165-65. * Shaft shall_be subjected to Dye Penetration and Ultrasonic Tests, * Wearing rings shall be subjected to Dye Penetration Test. * Verification of material, witnessing of pouring, casting and inspection of finalized fabricated/cast castings. * Inspection of finished castings for impeller and verification of materials. * Inspection of pump shaft and verification of meterial. * Witnessing of NDT/review of NOT reports. * Static balancing test for impeller & dynamic balancing of complete rotating parts as per ISO- 1940. * Complete inspection of assembled pump. b) Hydrostatic Testing The pump casing shall be hydrostatically tested at 150% of the shut- off pressure. Pressure shall be maintained for a period of not less than thiny (30) minutes. While arriving at the above values maximum suction pressure shall be taken into account cc) Performance Test at Shop i) Each pump shall have to be tested to determine the Performance curves of the pumps. These tests are to be conducted in presence of Owner's representative as per the fequirements of the Standards of Hydraulic institute of USA (ASME-Power Test Code PTC 8.2/BS-599). Or any other equivalent standard but the tolerances on head discharge and power shall be as specified in HIS, USA. ii) Performance tests are to be conducted to cover the entire range of operation of the pumps. These shall be carried out to ‘span 130% of rated capacity up to pump shut-off condition, (1920108 SPC-2210V2H-SECA.000) Page: vaasze 2x600 MW Long Phu 1 EPC RFP Document ‘A minimum of five combinations of head end capacity are to be achieved during testing to establish the performance curves, including the design capacity point, shut-off point and the two extremities of the range of operation as specified in the annexures. After completion of performance test, all pumps shall be stripped down for inspection of intemals. ii) Tests shall be conducted with actual drive motors being furnished vy) PSH tests are to be conducted on one pump of each type at 3% head drop conditions, if specified in the pump Annexures. ¥) Mechanical run test shall be carried out on all pumps to determine the vibration levels, noise levels etc. This test shall be conducted at site also. However, test value al site shall be used for the acceptance of the equipment. ¢) Field Tests i) Each pump shall be operated during the performance and acceptance test period and its performance will be observed for suttablity to the plant system and conformity to specifications while handling the specified fluid ji) Each pump found deficient or unsuitable shall be retested to determine the suitability of the pump for the intended application. The cost incurred towards the retest and corrective ‘measures shall be to the Contractor's account. The Contractor shall be fully responsible in rectifying the deficiency or replace the equipment by one meeting the performance requirements. 7.00.00 DRAWINGS, DATA, CURVES AND INFORMATION 7.01.00 The Tenderer shall submit the following along with his formal proposal besides the different information plete required as indicated elsewhere in this, section 7.01.01 Drawings a) General arrangement drawings showing the principal dimensions, weight and location of the suction and discharge connections of the pumps offered. Details of lubrication and sealing arrangement shall be included b} Typical cross-section drawing showing various components of the Pumps offered materials of construction ete. (19-2010%-6-SPC-2210.VZH SEGAL doe) Page: V2HS219 2x600 MW Long Phu 4 EPC RFP Document 7.01.02 Data and Curves 2) Determination of pump total dynamic head and rated capacity ss per guidelines specified in Section-I of this Volume. Detailed calculations Shall be shown by the Tenderer. b) Anticipated performance curves showing the following characteristics, i) Capacity vs. head Capacity vs. power Capazily vs. efficiency iv) Capacity vs. NPSH required v] System resistance curves ©) Speed vs. torque curve of the pump corresponding to recommended mode of pump starting superimoosed on speed vs. torque curves of the drive unit corresponding to 80%, 90%, 100% of the rated voltage (applicable only in the cases of pumps with drive motor power rating of 100 KW and above). 4) Completely filled-in Technical particulars enclosed under Volume-IIl of this specification. 7.02.00 The successful Contractor shall furnish the following drawingsidata for approval after award of the contract. 7.02.01 Final versions of all the drawings, documents as specified in clause no. 7.01.00 above. 7.02.02 Pump foundation details along with all design loads, direction and points of application. 7.02.03 Test reports, test certificates and other particulars. 7.02.04 All other applicable drawings and documents as specified in Volume A of this specification. (11-2010-6-SPO-2210-V2H SECA dox) Page: VoHSa10 2x600 MW Long Phu 1 EPC RFP Document TECHNICAL DATASHEET Pump Name Type Design Code No. of Pumps Required No. of Pumps Working Pumps Working Parallel Duty Location Drive Type OPERATING CONDITIONS, EACH PUMP Liquid Operating Temp Rated Capacity Total Head at Rated Capacity Specific Gravity of Liquid Shut-off Head CONSTRUCTION OF PUMP Shaft Sealing Gland Lube/ Sealing Bearing Lubrication Pump Drive Connection MATERIAL OF CONSTRUCTION OF PUMP Casing Shaft Impetier Wear Rings on Impeller and Casing PUMP DRIVE MOTOR DETAILS Supply Voltage/Phase/Frequency Class of Insulation Margin for Motor KW cccw PUMPS: Closed Cycle Cooling Water Pumps Horizontal Centrifugal ‘As mentioned in Cl. 2.00.00 of this, spec. Two (2) One (1) None Continuous Indoor Motor Demineralized Water Tenderer to furnish Tenderer to furnish Tenderer to furnish 4 To be furnished by the Tenderer Mechanical Seal Self Oil ring type or Anti-friction type Gear coupling with coupling guard 316 Stainless Steo! 316 Stainless Steel 316 Stainless Stee! 316 Slainiess Stee! See Specification No. 11-2010-K- G-SPC-2210-V2F 1-SEC-I.doc F insulation but limited to class B temperature rise. 15% on pump KW at rated duty or next higher size standard HP rating motor (11-2010K-G SPC-2210-V2H SEGA do2) one: V2HSt1 2x600 MW Long Phu 1 EPC RFP Document ANNEXURE.I TECHNICAL DATASHEET FOR ‘ACW PUMPS Pump Name ‘Auviliary Cooling Water Pumps Type Horizontal Centrifugal Design Code As mentioned in Cl. 2.00.00 of this, spec. No. of Pumps Required Four (4), Two (2) for each unit No. of Pumps Working Two (2), One (1) for each unit Pumps Working Parallel None Duty Continuous Location Indoor Drive Type Motor OPERATING CONDITIONS, EACH PUMP Liquid River Water Operating Temp 30°c Rated Capacity Tenderer to furnish Total Head at Rated Capacity Tenderer to furnish ‘Specific Gravity of Liquid 1 Shut-off Head To be furnished by the Tenderer CONSTRUCTION OF PUMP Shatt Sealing Mechanical Seal Gland Lube/ Seating Selt Bearing Lubrication Pump Drive Connection Geer coupling with coupling guard MATERIAL OF CONSTRUCTION OF PUMP Casing Cast Carbon Stee! Shaft Carbon Stee! Impeller 316 Stainioss Stoo! Wear Rings on impeller and Casing PUMP DRIVE MOTOR DETAILS Supply Vottage/Phase/Frequency Class of Insulation Margin for Motor KW 316 Stainless Steel See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-Il. doc F insulation but limited (0 class B temperature rise. 18% on pump KW at rated duty or next higher size standard HP rating motor (12010. SPC-2710.V2H SECA. A02) Page: V2HSI12 2x600 MW Long Phu 1 EPC RFP Document ANNEXURE-IIL TECHNICAL DATASHEET FOR RW FORWARDING PUMPS Pump Name Type Design Code No. of Pumps Required No. of Pumps Working Pumps Working Parallel Duty Location Drive Type OPERATING CONDITIONS, EACH PUMP Liquid Operating Temp Rated Capacity Total Head at Rated Capacity Specific Gravity of Liquid Shut-off Head CONSTRUCTION OF PUMP Shatt Sealing Gland Lube/ Seating Bearing Lubrication Pump Drive Connection MATERIAL OF CONSTRUCTION OF PUMP Casing Shaft Impeller Wear Rings on Impeller and Casing PUMP DRIVE MOTOR DETAILS Supply Voltage/Phase/Frequency Class of Insulation Margin for Motor KW Raw Water Forwarding Pumps Horizontal Centrifugal ‘As mentioned in Cl. 2.00.00 of this spec. Four (4) Two (2) Two (2) Continuous Indoor Motor River Water 30°C Tenderer to furnish Tenderer to furnish 1 To be furnished by the Tenderer Mechanical Seal Selt Oi ring type or Antisriction type Geer coupling with coupling guard Cast Carbon Steel Carbon Stee! 316 Stainless Steal 316 Stainless Stee! See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-Il.doc F insulation but limited to class B temperature rise. 15% on pump KW at rated duty or next higher size standard HP rating motor (79-20104-6:5PC-2210.V2H SECAL02) Page: V2RSat3 2x600 MW Long Phu 1 _EPC RFP Document ANNEXUREV TECHNICAL DATASHEET FOR PT SYSTEM FEED PUMPS Pump Name Pre-Treatment System Feed Pumps Type Horizontal Centrifugal Design Code ‘AS mentioned in Cl. 2.00.00 of this spec. No. of Pumps Required : Two (2) No. of Pumps Working One (1) Pumps Working Parallel None Duty Continuous Location Indoor Drive Type Motor OPERATING CONDITIONS, EACH PUMP Liquid River Water Operating Temp 30°C Rated Capacity Tenderer to furnish Total Head at Rated Capacity Tenderer to furnish Specific Gravity of Licuid 4 Shut-off Head To be furnished by the Tenderer CONSTRUCTION OF PUMP. Shaft Sealing Mechanical Seal Gland Lube! Sealing Self Bearing Lubrication Oil ring type or Anti-friction type Pump Drive Connection Geer coupling with coupling guard MATERIAL OF CONSTRUCTION OF PUMP Casing Cast Carbon Stee! Shaft Carbon Steel Impetter 316 Stainless Stee! Wear Rings on Impeller and Casing 346 Stainless Stee! PUMP DRIVE MOTOR DETAILS ‘Supply Voltage/Phase/Frequency See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-Il.doc Class of Insulation F insulation but limited to class B temperature rise. Margin for Motor KW 2 15% on pump KW at rated duty or next higher size standard HP rating motor (17-2010%-6-SPC-2210.V2H SECA 08) Page: VOHSI14 2x600 MW Long Phu 1 EPC RFP Document ANNEXURE-V TECHNICAL DATASHEET FOR FILTERED WATER PUMPS Pump Name Filtered Water Pumps Type Horizontal Centrifugal Design Code ‘As mentioned in Cl, 2.00.00 of this spec. No. of Pumps Required Two (2) No. of Pumps Working ‘One (1) Pumps Working Parallel None Duty Continuous Location Indoor Drive Type Motor OPERATING CONDITIONS, EACH PUMP Liquid Filtered Water Operating Temp Tenderer to furnish Rated Capacity Tenderer to furnish Total Head at Rated Capacity Specific Gravity of Liquid Shut-off Head CONSTRUCTION OF PUMP Shaft Sealing Gland Lube/ Seating Bearing Lubrication Pump Drive Connection MATERIAL OF CONSTRUCTION OF PUMP Cesing Shaft Impeller Wear Rings on Impeller and Casing PUMP DRIVE MOTOR DETAILS Supply Voltage/Phase/Frequency Class of Insulation ‘Margin for Motor KW Tenderer to furnish 1 To be furnished by the Tenderer Mechanical Seal Selt Oil ring type or Anti-friction type Geer coupling with coupling guard 316 Stainless Stee! 316 Stainless Stee! 316 Stainless Stee! 316 Stainless Steet ‘See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-ILdoc F insutation but limited to class B temperature rise 18% on pump KW at rated duty or next higher size standard HP rating motor (17-20104-6-SPC-2210.V2H SECAL doe) Page: V2HSanS 2x600 MW Long Phu 4 _EPC RFP Document ANNEXURE-VI TECHNICAL DATASHEET FOR DM TRANSFER PUMPS Pump Name Type Design Code No. of Pumps Required No. of Pumps Working Pumps Working Parallel Duty Location Drive Type OPERATING CONDITIONS, EACH PUMP Liquid Operating Temp Rated Capacity Total Head at Rated Capacity Specific Gravity of Liquid Shut-off Head CONSTRUCTION OF PUMP Shaft Sealing Gland Lube/ Sealing Bearing Lubrication Pump Drive Connection MATERIAL OF CONSTRUCTION OF PUMP Casing Shaft Impeller Weer Rings on Impeller and Casing PUMP DRIVE MOTOR DETAILS Supply Voltage/Phase/Frequency Class of Insulation Margin for Motor KW DM Transfer Pumps Horizontal Centrifugal ‘As mentioned in Cl, 2.00.00 of this spec. Two (2) ‘One (1) None Continuous Indoor Motor DM Water Tenderer to furnish Tenderer to furnish Tenderer to furnish 1 To be furnished by the Tenderer Mechanical Seal Selt Oil ring type or Anti-friction type Geer coupling with coupling guard 316 Stainless Stee! 316 Stainless Stee! 316 Stainless Stee! 316 Stainless Stee! See Specification No. 11-2010-K- G-SPC-2210-V2F1-SECI.doc F insulation but limited to class B temperature rise. 15% on pump KW at rated duty or next higher size standard HP rating motor (11-2010%-G-SPC-2210.V2H SECA doe) Pane: V2HSU16 2x600 MW Long Phu 1 _ EPC RFP Document ANNEXURE-VII TECHNICAL DATASHEET FOR FRESH WATER TRANSFER PUMPS Pump Name Type Design Code No. of Pumps Required No. of Pumps Working Pumps Working Parallel Duty Location Drive Type OPERATING CONDITIONS, EACH PUMP Liquid Operating Temp Rated Capacity Total Head at Rated Capacity Specific Gravity of Liquid Shut-off Head CONSTRUCTION OF PUMP Shaft Sealing Gland Lube/ Sealing Bearing Lubrication Pump Drive Connection MATERIAL OF CONSTRUCTION OF PUMP Casing Shaft Impeller Wear Rings on Impeller and Casing PUMP DRIVE MOTOR DETAILS Supply Voltage/Phase/Frequency Class of Insulation Margin for Motor KW Fresh Water Transfer Pumps Horizontal Centrifugal ‘As mentioned in Cl, 2.00.00 of this spec. Two (2) ‘One (1) None Intermittent Indoor Motor Fresh Weter Tenderer to furnish Tenderer to furnish Tenderer to furnish 1 To be furnished by the Tenderer Mechanical Seal Self Oil ring type or Anti-friction type Geer coupling with coupling guard 316 Stainiess Stee! 316 Stainless Stee! 346 Stainiess Stee! 316 Stainless Stee! ‘See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-ll doc F insulation but limited to class B temperature rise 16% on pump KW at rated duty or next higher size standard HP rating motor (17-20104-6-SPO-2210-V2H SEGAL 05) Page: V2HS217 2x600 MW Long Pau 4 EPC RFP Document ANNEXURE-VIIl TECHNICAL DATASHEET FOR POTABLE WATER PUMPS Pump Name Potable Water Pumps Type Horizontal Centrifugal Design Code ‘As mentioned in Cl. 2.00.00 of this spec. No. of Pumps Required Two (2) No. of Pumps Working ‘One (1) Pumps Working Parallel None Duty Intermittent Location Indoor Drive Type Motor OPERATING CONDITIONS, EACH PUMP Liquid Potable Water Operating Temp Tenderer to furnish Rated Capacity Tenderer to furnish Total Head at Rated Capacity Tenderer to furnish Specific Gravity of Liquid 1 Shut-off Head To be furnished by the Tenderer CONSTRUCTION OF PUMP Shait Sealing Mechanical Seal Gland Lube/ Sealing Selt Bearing Lubrication Oil ring type or Anti-friction type Pump Drive Connection Gear coupling with coupling guard MATERIAL OF CONSTRUCTION OF PUMP Casing 316 Siainiess Stee! Shaft 316 Stainiess Steet Impetter 316 Stainiess Stee! ‘Wear Rings on impeller and Casing 316 Stainless Stee! PUMP DRIVE MOTOR DETAILS ‘Supply Voltage/Phase/Frequency Class of Insulation Margin for Motor KW See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-II.doc F insulation but limited to class B temperature rise 15% on pump KW at rated duty or next higher size standard HP rating motor (11-20108-6-5PC-2210.VZH-SECALA00) Pago VeHSate 2x600 MW Long Phu 1 EPC RFP Document ANNEXURE-IX TECHNICAL DATASHEET FOR CONDENSATE TRANSFER PUMPS Pump Name Type Design Code No. of Pumps Required No. of Fumps Working Pumps Working Parallel Duty Location Drive Type OPERATING CONDITIONS, EACH PUMP Liquid Operating Temp Rated Capacity Total Head at Rated Capacity Specific Gravity of Liquid Shut-off Head CONSTRUCTION OF PUMP Shatt Sealing Gland Lube/ Sealing Bearing Lubrication Pump Drive Connection MATERIAL OF CONSTRUCTION OF PUMP Cesing Shaft Impeller ‘Wear Rings on Impeller and Casing PUMP DRIVE MOTOR DETAILS ‘Supply Voltage/Phase/Frequency Class of Insulation Margin for Motor KW Condensate Transfer Pumps Horizontal Centrifugal As mentioned in Cl. 2.00.00 of spec. Four (4), Two (2) for each unit Two (2), One (1) for each unit None Continuous Indoor Motor Condensate Tenderer to furnish Tenderer to furnish Tenderer to furnish j To be furnished by the Tenderer Mechanical Seal Self Oil ring type or Anti-iiction type Gear coupling with coupling guard 316 Stainless Stee! 316 Stainless Steel 316 Stainless Steal 316 Stainless Stee! ‘See Specification No. 11-2010-K- G-SPC-2210-V2F1-SEC-Il.doc F insulation but limited to class B temperature rise 15% on pump KW at rated duty or next higher size standard HP rating motor (-20104-6-5PC-2210.V2H-SECAL <0") Page: VaHsats

You might also like