This tech note introduces how to connect Siemens S7-300 MPI Port with PanelMaster
HMI.
MPI Port
<S7-300 CPU>
Create a new project follow below steps and set the CPU communication format.
Page 2 of 9
www.cermate.com
TND511-E0
Page 3 of 9
www.cermate.com
TND511-E0
<Insert a CPU unit into slot2, double it enter the properties window.>
Under CPU properties window, you can see the standard transmission rate is 187.5Kbps. Please use it
to link with PV series HMI directly.
Page 4 of 9
www.cermate.com
TND511-E0
485 +
485+
485 -
485-
SG
SG
HMI Side
485 TX+
485+
485 TX-
485-
SG
SG
Page 5 of 9
www.cermate.com
TND511-E0
Note:
We will suggest you the PLC and HMI address node do not set 0 or 1:
Node 0: reserve for PC / WinCC
Node 1: Step7 Software
2) HMI setting:
Select
Page 6 of 9
www.cermate.com
TND511-E0
Word Devices:
Page 7 of 9
www.cermate.com
TND511-E0
Page 8 of 9
www.cermate.com
TND511-E0