Professional Documents
Culture Documents
08 FosterWheeler DCU Operational Optimization PDF
08 FosterWheeler DCU Operational Optimization PDF
Jesus R. Cabello
Technical Service Director
RIO DE JANEIRO
29 Sept 3 Oct 2014
Design Details
Fractionator
Safer to operate
6
PXX
P9A, P23A
)
P9B, P23B
PSVs
22A
PSVs
To
Blowdown
P21A
21A
9A, 23A
A/F
9B, 23B
26A
8A
Vent
4A
P17A
Top head
8B
To Blowdown
Settling Drum
18A
PTHA
26B
17A
1A
2B
22B
A/F
18B
4B
2A
21B
Vent
P4B
P4A
P21B
Top head
P17B
1B
17B
PTHB
vapor line
19A
Drum
840CV-01
20A
19B
P19B
P1B
P1A
P19A
3A
Drum
840CV-02
20B
To Frac
Quench
Quench
Steam
Steam
5A
24A
25A
25B
24B
6A
PBHA
feed line
PBHB
6B
P6A
Btm head
7A
P7A
utility header
16A
Btm Drain
14A
Water
13A
Steam
12A
P12A
10A
P6B
7B
FEED
15A
11A
P10A
To
Condensate
Drum
P7B
Btm head
P12B
15B
11B
10B
P10B
12B
13B
Steam
14B
Water
16B
Btm Drain
Feedstock
High sodium
High asphaltenes
Incompatible crude blends
Coker Heater
Coker Fractionator
Low overhead temperatures salting
High bottoms temperatures coking (rare, typically seen with HHCGO
product operations)
8
Feedstock
Coker Heater
Double-fired
Longer run lengths if processing heavy feeds
On-line spalling more effective
Better temperature control with individual convection sections
Off-line decoking: steam-air, pigging
9
Coker Fractionator
Salting
Provide water wash system at the top of the tower
Increase overhead product endpoint
Coking
External quench for HHCGO product draw
10
13
14
Suspected feedstock
High solid / fines content
High paraffinic feeds cracks quicker than aromatic feeds
High sodium feeds can increase the rate of cracking / rate of gas going
through the liquids in the drum
19
Design
Provide adequate Coke Drum outage
Provide adequate Coke Drum diameter (make note of maximum vapor
velocity limit)
Provide adequate number and type of Coke Drum level detectors
Operation
20
21
Unheading
Manual (more time required than automatic)
Automatic
Remote operation
Automated Cutting Systems
Vendor supplied (Flowserve and Ruhrpumpen)
Pressure Test
15 minutes minimum even with slide valves
Ensures that water vaporized from drum walls during depressure
Minimize water going to coke condensate and blowdown
Too much water may lead to pump cavitation
Drum Switch
23
24
Operating conditions
Coking cycle time
25
Higher is better
Lower is better
Lower is better, but
26
27
28
29
30
Shot
Sponge
Low asphaltene feedstock
High pressure / moderate
recycle
Lower liquid / higher coke yield
40-70 (Hvy) / 70-100 (Lt) HGI
Fuel / anode grade
31
Needle
Low asphaltene feedstock /
aromatic tar
Very high pressure / high
recycle
70-110 HGI
Coke production operation
Electric grade
33
www.fwc.com