You are on page 1of 30

PDVSA

MANUAL DE INGENIERIA DE DISEO


VOLUMEN 6
PROCEDIMIENTO DE INGENIERIA

PDVSA N

LTP2.7

TITULO

HORNOS DE PROCESO, REQUISICION, ANALISIS


DE OFERTAS Y DETALLES DE COMPRA

SEP.96

REVISION GENERAL

29

AGO.88

PARA APROBACION

13

REV.

FECHA

APROB. Jos Gilarranz

E PDVSA, 1983

DESCRIPCION
FECHA AGO.88

PAG.
APROB. Antonio Ortiz

L.T.

E.J.

A.N.
J.S.

REV.

APROB. APROB.
FECHA AGO.88

ESPECIALISTAS

PROCEDIMIENTO DE INGENIERIA

PDVSA
.Men Principal

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA
Indice manual

Indice volumen

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 1
Indice norma

Indice
1 INTRODUCCION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

2 PREPARACION DE ESPECIFICACIONES DE DISEO . . . . . . . . .

3 INFORMACION SOBRE PROCESOS . . . . . . . . . . . . . . . . . . . . . . . .

4 DISEO MECANICO DE LOS HORNOS . . . . . . . . . . . . . . . . . . . . . .

5 REQUISICION DE HORNOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

6 PREPARACION DE LA REQUISICION DE COMPRA . . . . . . . . . . .

7 FORMATOS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Indice volumen

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 2
Indice norma

INTRODUCCION
La coordinacin de Ingeniera Mecnica tiene la responsabilidad de hacer las
especificaciones, requisiciones y seguimiento de fabricacin de los Hornos de
Proceso.
Se debern aplicar los procedimientos generales establecidos en su
organizacin para requisitos de equipos, anlisis de ofertas, compra y
seguimiento.

PREPARACION DE ESPECIFICACIONES DE DISEO


Se deber usar la Especificacin de Ingeniera PDVSA B201PR,
Calentadores de Fuego Directo.

INFORMACION SOBRE PROCESOS


La informacin sobre procesos le ser facilitada al Ingeniero de Proyectos por el
Ingeniero Jefe de Procesos. El Ingeniero Jefe de Procesos deber enviar una
comunicacin interna al Gerente de Proyectos estableciendo los criterios y
parmetros de diseo para los calentadores.

DISEO MECANICO DE LOS HORNOS


El diseo mecnico de los hornos estar a cargo del ingeniero especializado bajo
la supervisin del Gerente de Proyectos. El especialista deber llenar las Hojas
de Datos correspondientes a los hornos de proceso. Las Hojas de Datos definen
claramente las responsabilidades de cada una de las partes involucradas en el
diseo, fabricacin, inspeccin, suministro y aprobacin de los equipos. Toda
informacin sobre procesos o cualquier caracterstica mecnica que se necesite
se deber incluir en las Hojas de Datos. Las caractersticas mecnicas a que esto
se refiere sern las limitaciones especiales que pueden emerger en un proyecto
particular tales como, limitaciones del terreno, altura de las chimeneas,
localizacin de plataforma, normas locales especiales, etc.

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Indice volumen

Pgina 3
Indice norma

REQUISICION DE HORNOS
La siguiente lista define las responsabilidades del ingeniero especialista bajo la
direccin del Gerente de Proyecto, al efectuar la requisicin de calentadores.
a.
b.
c.
d.

e.

Coordinacin de eventos con el vendedor/fabricante


Completar las Hojas de Datos de acuerdo a los criterios de diseo
establecidos por el Ingeniero Jefe.
Hacer el paquete de requisicin de equipos.
Cuando se hayan recibido las ofertas, se deber preparar su anlisis y
recomendar un fabricante (el anexo HOJAS DE DATOS PARA HORNOS DE
PROCESO se puede pegar por el dorso, para comparar las ofertas de los
diferentes fabricantes).
Emisin de la requisicin de compra.

PREPARACION DE LA REQUISICION DE COMPRA


Se modificar una copia adicional de la requisicin para que sirva como orden de
compra. Toda informacin que se hubiera omitido en la requisicin para cotizacin
se deber completar en esta oportunidad.

FORMATOS
Formato No. 1 Hoja de Datos Sistema Internacional
Formato No. 2 Hoja de Datos Unidades Inglesas
(Ambos en ingls)
Formato No. 3 Lista de especificaciones particulares
El Formato No. 3 se considera parte de las hojas de datos y conforman las
preferencias de PDVSA y/o las excepciones del proyecto para adquisicin o
modificacin de hornos.

PROCEDIMIENTO DE INGENIERIA

PDVSA
.Men Principal

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA
Indice manual

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Indice volumen

FIRED HEATERS DATA SHEET


(SI UNITS)
(FORMATO 1)

Pgina 4
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI


FIRED HEATER DATA SHEET
SI UNITS

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Process Design Condition


* 1 Total duty per heater, MW
2 Heater Section
* 3 Service
4 Heat absorption, MW
* 5 Fluid name
* 6 Flow rate, kg/s
3
* 7 Flow rate, dm /s
* 8
9
* 10
* 11

Pressure drop (allowable, clean / fouled), kPa


Pressure drop (calculated, clean / fouled), kPa
Fouling allowance, m 2 C/W
Thermal conductivity of coke/scale, W/m C

2
* 12 Average radiant flux density (allowable), W/m
13 Average radiant flux density (calculated), W/m 2
2
* 14 Average convection flux density (allowable),W/m 2
15 Average convection flux density (calculated), W/m

16 Maximum radiant flux density, W/m 2


17 Maximum convection flux density, W/m 2
* 18 Velocity limitation
* 19 Maximum allowable inside film temperature, C
Inlet Conditions:
* 20 Temperature C
* 21 Pressure, kPa
* 22 Liquid flow, kg/s
* 23 Vapor flow, kg/s
* 24 Gravity, liquid,API (specific gravity al 15 C)
* 25 Vapor, molecular weight
* 26 Viscosity, liquid, mPa.s
*
*
*
*
*

PDVSA LTP2.7

27 Viscosity, vapor, mPa.s


28 Specific heat, liquid, KJ/kg C
29 Specific heat, vapor, KJ/kg C
30 Thermal conductivity, liquid, W/m C
31 Thermal conductivity, vapor, W/m C
Outlet Conditions:

* 32 Temperature, C
* 33 Pressure, kPa
* 34 Liquid flow, kg/s
* 35 Vapor, flow, kg/s
* 36 Gravity, liquid, API (specific gravity at 15 C)
* 37 Vapor, molecular weight
* 38 Viscosity, liquid, mPa.s
* 39 Viscosity, vapor, mPa.s
* 40 Specific heat, liquid, kJ/kg C
* 41 Specific heat, vapor, kJ/kg C
* 42 Thermal conductivity, liquid, W/m C
* 43 Thermal conductivity, vapor, W/m C

Remarks and Special Requirements, incluiding ShortTerm Operating Conditions:


* 44 Distillation data should be attached for vaporization service
* 45 Other:

REVISION

FECHA

SEP.96

Indice volumen
Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
1 of

Pgina 5
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI

Combustion Design Conditions


*2 Excess air, porcent
3 Calculated heat release, MW (LHV)
4 Calculated fuel efficiency, porcent (LHV)
5 Calculated thermal efficiency, porcent (LHV)
6 Actual thermal eficiency, porcent (LHV)
7 Radiation loss, porcent of heat release (LHV)
Flue gas temperature leaving radiant section, C
Flue gas temperature leaving convection section, C
Flue gas temperature leaving air heater, (uncorrected), C
Flue gas temperature leaving air heater, (corrected), C

12 Maximum flue gas mass velocity through convection section, kg/(s.m2)


13 Volumetric heat release, W/m3(LHV)
*14 Ambient air temperature, C
*15 Air temperature, stack design,C
16 Air temperature leaving air heater, C
*17 Altitude above sea level, m
18 Minimum furnace draft / location, kPa
*19 Note: A fuel savings of

MW will offset a $ 10.000 increase in furnace cost (erected).

Fuel Characteristics
Design

Alternates

*20 Type of fuel


*21 Heating value (LVH), KJ/kg
3

*22
*23
*24
*25

Heating value (LHV), KJ/Nm


Specific gravity at 15C or API
H/C ratio (by weight)
Viscosity, @
C, mPa.s

*26
*27
*28
*29

Viscosity, @
Total salts, ppm
Vanadium, ppm
Sodium, ppm

*30
*31
*32
*33
*34
*35
*36
*37
*38
*39
*40

Fixed nitrogen, ppm


Sulfur, porcent by weight
Hidrogen sulfide, percent by volume
Ash, porcent by weight
Liquids: ASTM initial boiling point, C
ASTM end point, C
Gases: Molecular weight
Composition mol porcent
Temperature at burner, C
Fuel pressure (available at bumer), kPa
Atomizing air/ steam preasure, kPa

C, mPa.s

Mechanical Design Conditions

General:
*41 Plot limitations
*42 Tube limitations

SEP.96

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
2 of

*1 Type of fuel

8
9
10
11

FECHA

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

FIRED HEATER DATA SHEET


SI UNITS

REVISION

Minimum stack height


Noise limitations

Pgina 6
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

FIRED HEATER DATA SHEET


SI UNITS

Structural Design Data:


Wind occurrence
Seismic zone

Heater Section:
Coil Design
4
5
6
7
8
9
* 10
* 11
* 12
13
* 14
15
16

Design basis for tube wall thickness (code or specification)


Design basis for rupture strength (minimum or average)
Design life, hr
Elastic design pressure, kPa
Rupture design pressure, kPa
Temperature allowance, C
Corrosion allowance, mm
Stress relieve (yes or no)
Weld inspection requirements, Xray or other (no. of Welds and degree of coverage)
Hydrostatic test pressure, kPa
Maximum tube metal temperature (clean), C
Design tube metal temperature, C
Inside film coefficient, W/m2 C

Coil Configuration:
17
18
19
20
21
22

Tubes(vertical or horizontal)
No. of flow passes / tubes per row
Effective tube length, m
Bare tubes, number
Bare tubes, total exposed surface, m2
Extended surface tubes, number

23 Extended surface tubes, total exposed surface, m2


24 Tube spacing, centertocenter (staggered) (inline), mm
Tubes:
* 25 Material (ASTM specifications and grade)
26 Outside diameter, mm
27 Wall thickness (minimum) (average), mm
28 Overall tube length, m
29 No. of intermediate welds
29a Distance from center line of tube to wall, inch
Description of Extended Surface:
30
31
32
33
34
35

Type (stude, segmented line, or solid line)


Material
Dimensions (height x diameter / thickness), mm
Spacing
Maximum tip temperature, C
Extension ratio

Plug Type Headers:


* 36
37
* 38
39
40

Location (one end or both ends)


Material (ASTM specification and grade)
Manufacturer and type
Nominal rating
Welded or rolled joint

Return Bends:
* 41
42

Location (header box or firebox)


Material (ASTM specification and grade)

FECHA

SEP.96

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
3 of

Mechanical Design Conditions (continued)

* 1 Wind velocity
* 2 Wind exposure
* 3 Minimum ambient air temperature, C

REVISION

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Para llenar el formato, haga click AQUI

*
*
*
*
*
*

PDVSA LTP2.7

Pgina 7
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal
Para llenar el formato, haga click AQUI
FIRED HEATER DATA SHEET
SI UNITS

Indice manual

REVISION

FECHA

SEP.96

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Pgina 8
Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
4 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Terminals:
* 1 Type (welded or flanged)
Inlet:
2 Material (ASTM specification and grade)
3 Size / rating, schedule or thickness
4 Number of Terminals
Outlet:
5 Material (ASTM specification and grade)
6 Size / rating, schedule or thickness
* 7 Number of terminals
Manifolds:
* 8 Connection to tubes (welded or flanged)
9 Location (internal of external)
Intlet:
10 Material (ASTM specification and grade)
11 Size / schedule or thickness
12 Flange material (ASTM specification and grade)
13 Flange size and rating
Oulet:
14 Material (ASTM specification and grade)
15 Size / schedule or thickness
16 Flange material (ASTM specification and grade)
17 Flange size and rating
Crossovers:
* 18 Location (Internal of external)
* 19 Pipe material (ASTM specification and grades)
20 Pipe size / schedule or thickness
* 21 Flange material (ASTM specification and grade)
22 Flange size and rating
Tube Supports:
23 Location (top, bottom, intermediate)
24 Material (ASTM specification and grade)
25 Spacing
26 Coating (type and thickness)
Tube Guides:
27 Location and spacing
28 Material (ASTM specification and grade)
Settings:
Floor:
Hot face temperature: Calculated
29 Lining: Thickness
Materials / Thickness / service temperature
30
Anchor (type and materials)
31
32 Casing: Materials and thickness

Design

Temperature

Exposed Vertical Walls:


33

Lining: Thickness

34

Material / thickness / service temperature

35

Anchor (type and materials)

36

Casing: Materials and thickness

Hot face temperature: Calculated

Design

Temperature

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Para llenar el formato, haga click AQUI


FIRED HEATER DATA SHEET
SI UNITS

Indice manual

REVISION

FECHA

SEP.96

Pgina 9

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
5 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Shielded Vertical Walls:
1 Lining: Thickness
Hot face temperature: Calculated
2
Material / thickness / service temperature

Design

Anchor (type and materials)


4 Casing: Materials and thickness

Temperature

Arch:
5 Lining: thickness
Hot face temperature: calculated
6
Materials / thickness / service temperature
7
Anchor (type and materials)
8 Casing: Materials and thickness

Design

Temperature

Convection Walls:
9 Lining: Thickness
Hot face temperature: calculated
10
Material / thickness / service temperature

Design

11

Anchor (type and materials)


12 Casing: Materials and thickness

Temperature

Breeching:
13 Lining: Thickness
Hot face temperature: calculated
14
Materials / thickness / service temperature
15
Anchor (type and materials)
16 Casing: Materials and thickness
Flue Gas Ducts:
17 Location
18 Lining (internal of external)
19 Material and thickness
20 Anchor, type and material
21 Hot face design temperature, C
22 Cold face design temperature, C
Combustion Air Ducts:
23 Location
24 Lining (internal of external)
25 Material and thickness
26 Anchor, type and material
27 Hot face design temperature, C
Header Boxes:
28 Location

Hinged doors / bolted panels

29 Lining (materials and thickness)


30 Anchor (type and material)
31 Door / panel (material and thickness)
Plenum Chamber:
32 Lining (internal or external)
33 Anchor (type and material)

Material and thickness

34 Casign: Materials and thickness


35

Hot face design temperature

Cold face desing temperature

Design

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI


FIRED HEATER DATA SHEET
SI UNITS

REVISION

FECHA

SEP.96

Pgina 10

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
6 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Stack:
1 Location
Number
Inside metal diameter
2 Stack design metal temperature
Stack length
3 Plate, minimum thickness (including corrosion allowance)
* 4 Lining (internal or external)
Extent of lining
5 Material and thickness
6 Anchor, type and material
Bridgewall:
7 Height

Height above grade


Material

Material and thickness

C.A.

Location

Dampers:
8 Location
9 Material of blade
10 Material of shaft
* 11 Bearing type
12 Multiple or single blade
13 Description of provision for operation
14 Location and type of operator
Miscellaneous:
Platforms:

Access
From

By
Location/No.

Width

Length/Arc

Stairs / Ladder

Grade / Platform / Location, etc

15
16
17
18
19
20 Type of flooring, etc.

Doors:
21 Access
22

Number

Location

Size

Hinged or bolted

23
24
25 Observation
26
27 Tube removal
28 Inspection
29
30
31

Instrument and Auxiliary Connections:


32 Process fluid temperature
33 Flue gas combustion air temp.
34 Flue gas combustion air press
35 Flue gas combustion/O2 analyzer
36 Snuffing steam
37 Purge
38 Vents / drains
39 Tubeskin thermocouples
40

Number

Size

Type

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

FIRED HEATER DATA SHEET


SI UNITS

FECHA

SEP.96

Pgina 11

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Para llenar el formato, haga click AQUI

REVISION

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
7 of

Mechanical Design Conditions (continued)


Heater Section (continued):
* 1 Painting requirements

* 2 Galvanizing requirements

* 3 Internal coatings (casing, ducts, stack)

* 4 Fireproofing requirements

Burners and Auxiliary Equipment:


Burners :
5 Manufacture / type
6 Designation / size
7 Heat release (MW per burner) at design excess air:
Maximum

Location / orientation
No.

Normal

Maximum

8 Design pressure drop across burners kpa

@ Maximum heat release

9 Distance burner centerline to tube centerline: Horizontal


10 Distance burner centerline to unshielded refractory: Horizontal
11 Burner pilot: Capacity (MW)
Type of ignition

Vertical
Fuel

* 12 Special requirements (flame detection devices, safety interlocks, etc.)

Sootblowers:
13
14
15
16

Location
Manufacturer and type
Number
Maximum cleaning radius

17 Lane dimension (minimum clearance)


18 Orientation (horizontal or vertical)
* 19 Cleaning medium
* 20 Supply pressure / temperature
21 Flow rate per blower, kg/s
22 Materials of construction
* 23 Driver type (manual, air, or electric motor)
* 24 Control system type (auto or manual; sequential, local, or remote panel; etc.)

Vertical
Fuel pressure

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI

FECHA

SEP.96

Pgina 12

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

FIRED HEATER DATA SHEET


SI UNITS

REVISION

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
8 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Air Preheater Section:
1 System description (direct, indirect, or other)
2 Type (regenerative, recuperative, heat pipe, circulating, other)
3 Manufacturer

Model No.
Air Side

Design

Maximum

Flue Gas or Hot side


Minimum

Design

Maximum

Minimum

Performance:
4 Flow entering, kg/s
5 Bypass quantity, kg/s
6 Flow leaving, kg/s
7 Hot air recirculation, kg/s
8 Leakage, porcent
9 Temperature entering, C
10 Temperature leaving, C
(uncorrected)
11 Temperature leaving, C (corrected)
12 Mix temperature (after bypass), C
13 Pres. entering/leaving, kpa
14 Pressure drop (allowable), kPa
15 Pressure drop (calculated), kPa
16 Heat exchanged, MW
17 Transfer rate (clean), W/m2 C
18 MTD (uncorrected), C
19 Surface area, m2
20 Tube side fluid
* 21 Minimum allowable flue gas temp. C
22 Minimum metal temp. of flue gas side: allowable, C
23 Upper limit flue gas temperature, C
Utilities and Miscellaneous:
* 24 Plant air pressure, kPa
* 25 Steam: pressure, kPa
* 26 Water: pressure, kPa
* 27 Structural wind load, kg/m2
* 28 Elevation, m above sea level
29 Other
30
31
32
33

Minimum ambient air temp., C


Calculated, C

Instrument air pressure, kPa


Temperature, C
Temperature, C
Seismic factor
Relative humidity

Construction:
Regenerative type:
34 Horizontal shaft: Air inlet (left, right, above, below)
Vertical shaft: Air flow (up, down)
35 Internal air bypass (yes, no) and type of operator
36 Main drive

Baskets:
37 Cold end
38 Intermediate
39 Hot end

Auxiliary drive

Gage

Material

Depth (min)

Description

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

FIRED HEATER DATA SHEET


SI UNITS

FECHA

SEP.96

Pgina 13

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Para llenar el formato, haga click AQUI

REVISION

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
9 of

Mechanical Design Conditions (continued)


Air Preheater (continued):
Construction (continued):
Recuperative type:
1 No. of air passes
2 Description of surface

No. of tubes/air pass

3 Materials of construction
4 Intermediate air crossover duct: Included (yes, no)
Bolted or welded

With/without insulation

Heat Pipe:
5 Tube material
Outside diameter, mm
6 Air side fins (solid/segmented): Width, mm
Thickness, mm
7 Gas side fins (solid/segmented): Width, mm
8 Thickness, mm

No.
A.W./M.W.,mm
Height, mm
No. per inch

Material

No. per meter

Height, mm
Material

9 Tubes per row


No. of rows
10 Effective length: Air side
11 Maximum allowable soaking temperature, C

Pitch

Square, triangular
Flue gas side

IndirectCirculating type:
12 Air heater coil: material
Outside diameter, mm
13 Fin description

No.
Effective length

A.W./M.W.,mm

14 Tubes per row


No. of rows
15 Expansion tank
Valves
Note: See fired heater section of data sheets for flue gas coil details
Other Type:
16

Pitch

Square, triangular
Pumps

17
Accessories:
18 Soot blowers
19 Water wash
20 Fire extinguisher system
21 Controls
22 Insulation: external
23 Corrosion protection
24 Expansion provisions
25 External cold air bypass (yes/no)
26 External hot air recirculation (yes/no)

Internal

Damper operator type


Damper operator type
Forced Draft
Normal

Fans:
27
28
29
30
31
32
33
34
35

Flow rate, kg/s


Temperature, C
Static pressure, kPa
Revolutions per minute
Maximum allowable fan speed, rpm
Manufacturer and arrangement
Type and size
Bearing type
Coupling type

Design

Induced Draft
Normal

Design

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Para llenar el formato, haga click AQUI


FIRED HEATER DATA SHEET
SI UNITS

REVISION

FECHA

SEP.96

Pgina 14
Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page 10 of

Mechanical Design Conditions (continued)


Air Preheater Section (continued)
Construction (continued):
1
2
3
4

Casing materials of construction


Impeller materials of construction
Damper, type and location
Damper operator

* 5 Special requirements (noise limits, inlet screens, rain hoode, guide vanes, etc.)

Drivers:
Electric Motors:
6 Manufacture and type
7 Horsepower
8 Voltage/herthz/phase
9 Revolutions per minute

Forced Draft

Induced Draft

Turbines:
15 Manufacturer and type or designation
16 Horsepower, normal condition
17 Horsepower, design condition
18 Water rate, normal condition, kg/s/W
19 Water rate, design condition, kg/s/W
20 Revolutions per minute, normal condition
21 Revolutions per minute, design condition
*23 Steam conditions, inlet
*23 Steam conditions, outlet
24 Governor
25 Bearings, type and tube
*26 Special requirements

Forced Draft

Induced Draft

Transmission:

Forced Draft

Induced Draft

* 10
11
* 12
13
* 14

27
28
*29
30
31
*32

Enclosure
Insulation
Service factor
Bearings (type and tube)
Special requirements

Manufacturer and type


Ratio
Service factor
Lube system
Coupling manufacturer and type
Special requirements (clutches, coupling guards, etc).

PROCEDIMIENTO DE INGENIERIA

PDVSA
.Men Principal

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA
Indice manual

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 15

Indice volumen

FIRED HEATERS DATA SHEET


(CUSTOMARY UNITS)
(FORMATO 2)

Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI


FIRED HEATER DATA SHEET
CUSTOMARY UNITS

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Thermal consuctivity, vapor


Process Desing Conditions
* 1 Total duty per heater, mm Btu/hr
2 Heater Section
* 3 Service
4 Heat absorption, mm Btu/hr
* 5 Fluid name
* 6 Flow rate, lb/hr
* 7 Flow rate, bdp
* 8
9
* 10
* 11

Pressure drop (allowable, clean / fouled), psi


Pressure drop (calculated, clean / fouled), psi
Fouling allowance, in/hr Fft/Bln
Thermal conductivity of coke/scale Btu/hrFft2/in

2
* 12 Average radiant flux density (allowable), Btu/hrft
2
Btu/hrft
Average
radiant
flux
density
(calculated),
13
* 14 Average convection flux density (allowable), Btu/hrft2

15 Average convection flux density (calculated), Btu/hrft2


Btu/hrft2
17 Maximum convection flux density, Btu/hrft2
* 18 Velocity limitation
* 19 Maximum allowable inside film temperature, F
16 Maximum radiant flux density,

Inlet Conditions:
* 20 Temperature F
* 21 Pressure, psi (psi)
* 22 Liquid flow, lb/hr
* 23
* 24
* 25
* 26

Vapor flow, lb/hr


Gravity, liquid, API (specific gravity at 15F)
Vapor, molecular weight
Viscosity, liquid, cP

* 27
* 28
* 29
* 30
* 31

Viscosity, vapor, cP
Specific heat, liquid, Btu/lb F
Specific heat, vapor, BTU/lb F
Thermal conductivity, liquid, Btu/hrft2F/in
Thermal conductivity, vapor,, Btu/hrft2F/in

Outlet Conditions:
* 32
* 33
* 34
* 35
* 36
* 37
* 38
* 39
* 40
* 41
* 42
* 43

PDVSA LTP2.7

Temperature, F
Pressure, psig (psig)
Liquid flow, lb/hr
Vapor, flow, lb/hr
Gravity, liquid, API (specific gravity at 15F)
Vapor, molecular weight
Viscosity, liquid, cP
Viscosity, vapor, cP
Specific heat, liquid, Btu/lb F
Specific heat, vapor, Btu/lb F
Thermal conductivity, liquid, Btu/hrft2F/in
Thermal conductivity, vapor, Btu/hrft2F/in

Remarks and Special Requirements, incluiding ShortTerm Operating Conditions:


*44 Destilation data should be attached for vaporization service
*45 Other:

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
1 of

REVISION

FECHA

SEP.96

Pgina 16
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Indice volumen

Para llenar el formato, haga click AQUI


Service
Unit
FIRED HEATER DATA SHEET
CUSTOMARY UNITS

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
2 of

Type
Owner

Purchaser
Vendor
Date

Combustion Design Conditions


* 1 Type of fuel
* 2 Excess air, porcent
3 Calculated heat release, mm Bluhr (LHV)
4 Calculated fuel efficiency, porcent (LHV)
5 Calculated thermal efficiency porcent (LHV)
6 Actual thermal efficiency porcent (LHV)
7 Radiation loss, porcent of heat release (LHV)
8
9
10
11

Flue gas temperature leaving radiant section, F


Flue gas temperature leaving convection section, F
Flue gas temperature leaving air heater, (uncorrected), F
Flue gas temperature leaving air heater, (corrected), F

12 Maximum flue gas mass velocity through convection section, lb/sq ft


3

13 Volumetric heat release, Btu/hr.ft (LHV)


* 14 Ambient air temperature,F
* 15 Air temperature, stack design, F
16 Air temperature leaving air heater,F
* 17 Altitude above sea level, ft
18 Minimum furnace draft / location, H2O
* 19 Note: A fuel savings of

MW will offset a $ 10.000 increase in furnace cost (erected)


Fuel Characteristics
Design

Alternates

* 20 Type of fuel
* 21 Heating value (LVH), Btu/lb
* 22 Heating value (LHV), Btu/sci
or API
* 23 Specific gravity at 60 F

* 24 H/C ratio (by weight)


* 25 Viscosity, @
F, SSU
F, SSU

* 26
* 27
* 28
* 29

Viscosity, @
Total salts, ppm
Vanadium, ppm
Sodium, ppm

* 30
* 31
* 32
* 33
* 34
* 35
* 36
* 37
* 38
* 39
* 40

Fixed nitrogen, ppm


Sulfur, porcent by weight
Hidrogen sulfide, percent by volume
Ash, porcent by weight
Liquids: ASTM initial bolling point, F
ASTM end point, F
Gases: Molecular weight
Composition mol porcent
Temperature at burner,F
Fuel pressure (available at bumer), psig
Atomizing air/ steam preasure, Kpa

Mechanical Design Conditions


General:
*41 Plot limitations

Minimum stack height

*42 Tube limitations

Noise limitations

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 17
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

FIRED HEATER DATA SHEET


CUSTOMARY UNITS

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
3 of

Mechanical Design Conditions (continued)


Structural Design Data:
*1 Wind velocity
*2 Wind exposure
*3 Minimum ambient air temperature, F

Wind occurrence
Seismic zone

Heater Section:
Coil Design:
*4 Design basis for tube wall thickness (code or specification)
*5 Design basis for rupture strength (minimum or average)
*6 Design life, hr
*7 Elastic design pressure, psig
*8 Rupture design pressure, psig
*9 Temperature allowance, F
*10 Corrosion allowance, ln
*11 Stress relieve (yes or no)
*12 Weld inspection requirements, Xray or other (no. of Welds and degree of
coverage)
13 Hydrostatic test pressure, kPa
14 Maximum tube metal temperature (clean), F
15 Design tube metal temperature, F
16 Inside film coefficient, Btu/hrFft2
Coil Configuration:
17 Tubes(vertical or horizontal)
18 No. of flow passes / tubes per row
19 Effective tube length, ft
20 Bare tubes, number
21 Bare tubes, total exposed surface, ft2
22 Extended surface tubes, number
23 Extended surface tubes, total exposed surface, ft2
24 Tube spacing, centertocenter (staggered) (inline), in
Tubes:
*25 Material (ASTM specifications and grade)
26 Outside diameter, mm
27 Wall thickness (minimum) (average), mm
28 Overall tube length, lt
29 No. of intermediate welds
29A Distance from center line of tube to wall, inch
Description of Extended Surface:
30 Type (stude, segmented line, or solid line)
31 Material
32 Dimensions (height x diameter / thickness), in
33 Spacing
34 Maximum tip temperature, F
35 Extension ratio

Plug Type Headers:


36 Location (one end or both ends)
37
*38
39
40

Material (ASTM specification and grade)


Manufacturer and type
Nominal rating
Welded or rolled joint

Return Bends:
*41
Location (header box or firebox)
42
Material (ASTM specification and grade)

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 18
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal
Para llenar el formato, haga click AQUI
FIRED HEATER DATA SHEET
CUSTOMARY UNITS

Indice manual

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 19
Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
4 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Terminals:
*1 Type (welded or flanged)
Inlet:
2 Material (ASTM specification and grade)
3 Size / rating, schedule or thickness
4 Number of terminals
Outlet:
5 Material (ASTM specification and grade)
6 Size/Rating, schedule or thickness
7 Number of terminals
Manifolds:
*8 Connection to tubes (welded or flanged)
9 Location (internal of external)
Inlet:
10 Material (ASTM specification and grade)
11 Size / schedule or thickness
12 Flange material (ASTM specification and grade)
13 Flange size and rating
Outlet:
14 Material (ASTM specification and grade)
15 Size / schedule or thickness
16 Flange material (ASTM specification and grade)
17 Flange size and rating
Crossovers:
*18 Location (Internal of external)
*19 Pipe material (ASTM specification and grades)
20 Pipe size / schedule or thickness
*21 Flange material (ASTM specification and grade)
22 Flange size and rating
Tube Supports:
23 Location (top, bottom, intermediate)
24 Material (ASTM specification and grade)
25 Spacing
26 Coating (type and thickness)
Tube Guides:
27 Location and spacing
28 Material (ASTM specification and grade)
Settings:
Floor:
29 Lining: Thickness
Hot face temperature: Calculated
30
Materials / Thickness / service temperature
31
Anchor (type and materials)
32 Casing: Materials and thickness

Design

Temperature

Exposed Vertical Walls:


33 Lining: Thickness
34

35
36

Hot face temperature: Calculated

Design

Material / thickness / service temperature

Anchor (type and materials)


Casing: Materials and thickness

Temperature

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal
Para llenar el formato, haga click AQUI
FIRED HEATER DATA SHEET
CUSTOMARY UNITS

Indice manual

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
5 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Shielded Vertical Walls:
1 Lining: Thickness
Hot face temperature: Calculated
2
Material / thickness / service temperature

Design

Anchor (type and materials)


4 Casing: Materials and thickness

Temperature

Arch:
5 Lining: thickness
Hot face temperature: calculated
6
Materials / thickness / service temperature
7
Anchor (type and materials)
8 Casing: Materials and thickness

Design

Temperature

Convection Walls:
9 Lining: Thickness
Hot face temperature: calculated
10
Material / thickness / service temperature

Design

11

Anchor (type and materials)


12 Casing: Materials and thickness

Temperature

Breeching:
13 Lining: Thickness
Hot face temperature: calculated
14
Materials / thickness / service temperature
15
Anchor (type and materials)
16 Casing: Materials and thickness
Flue Gas Ducts:
17 Location
18 Lining (internal of external)
19 Material and thickness
20 Anchor, type and material
21 Hot face design temperature, F
22 Cold face design temperature, F
Combustion Air Ducts:
23 Location
24 Lining (internal of external)
25 Material and thickness
26 Anchor, type and material
27 Hot face design temperature, F
Header Boxes:
28 Location

Hinged doors / bolted panels

29 Lining (materials and thickness)


30 Anchor (type and material)
31 Door / panel (material and thickness)
Plenum Chamber:
32 Lining (internal or external)
33 Anchor (type and material)

Material and thickness

34 Casign: Materials and thickness


35

Hot face design temperature

Cold face desing temperature

Design

REVISION

FECHA

SEP.96

Pgina 20
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

FIRED HEATER DATA SHEET


CUSTOMARY UNITS

FECHA

SEP.96

Pgina 21

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

Para llenar el formato, haga click AQUI

REVISION

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
6 of

Mechanical Design Conditions (continued)


Heater Section (continued):
Stack:
1 Location
Number
2 Stack design metal temperature

Height above grade

Inside metal diameter


Stack length

3 Plate, minimum thickness (including corrosion allowance)


*4 Lining (internal or external)
5 Material and thickness

Material

C.A.

Extent of lining

6 Anchor, type and material


Bridgewall:
7 Height

Material and thickness

Location

Dampers:
8
9
10
*11

Location
Material of blade
Material of shaft
Bearing type

12 Multiple or single blade


13 Description of provision for operation
14 Location and type of operator
Miscellaneous:
Platforms:

Access
From

By
Location/No.

Width

Length/Arc

Stairs / Ladder

Grade / Platform / Location, etc

Location

Size

Hinged or bolted

15
16
17
18
19
20 Type of flooring, etc.
Doors:

Number

21 Access
22
23
24
25 Observation
26
27 Tube removal
28 Inspection
29
30
31
Instrument and Auxiliary Connections:
32 Process fluid temperature
33 Flue gas fluid combustion air temp.
34 Flue gas fluid combustion air press
35 Flue gas fluid combustion/O2 analyzer
36 Snuffing steam
37 Purge
38
39
40

Vents / drains
Tubeskin thermocouples

Number

Size

Type

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI

FECHA

SEP.96

Pgina 22

Indice volumen

Service
Unit
Type
Owner
Purchaser
Vendor
Date

FIRED HEATER DATA SHEET


CUSTOMARY UNITS

REVISION

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page
7 of

Mechanical Design Conditions (continued)

Heater Section (continued):


*1 Painting requirements

*2 Galvanizing requirements

*3 Internal coatings (casing, ducts, stack)

*4 Fireproofing requirements

Bumers and Auxiliary Equipment:


Bumers
Location / orientation

5 Manufacture / type
6 Designation / size
7 Heat release (mm BTU per bumer) at design excess air:
Maximum

No.

Normal

Maximum

8 Design pressure drop across burners H2O


9 Distance burner centerline to tube centerline: Horizontal
10 Distance burner centerline to unshielded refractory: Horizontal
11 Burner pilot: Capacity (mm Btu/hr)

@ Maximum heat release


Vertical
Vertical
Fuel

Type of ignition
*12 Special requirements (flame detection devices, safety interlocks, etc.)

Sootblowers:
13
14
15
16
17
18
*19
*20
21
22
*23

Location
Manufacturer and type
Number
Maximum cleaning radius
Lane dimension (minimum clearance)
Orientation (horizontal or vertical)
Cleaning medium
Supply pressure / temperature
Flow rate per blower, kg/s
Materials of construction
Driver type (manual, air, or electric motor)

*24 Control system type (auto or manual; sequential, local, or remote panel; etc.)

Fuel pressure

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI


FIRED HEATER DATA SHEET
CUSTOMARY UNITS

REVISION

FECHA

SEP.96

Pgina 23

Indice volumen

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page 8
of

Service
Unit
Type
Owner
Purchaser
Vendor
Date
Mechanical Design Conditions (continued)

Heater Section (continued):


Air Preheater Section:
1 System description (direct, indirect, or other)
2 Type (regenerative, recuperative, heat pipe, circulating, other)
3 Manufacturer

Model No.
Air Side

Flue Gas or Hot side

Performance:
Design
4
5
6
7
8

Maximum

Minimum

Design

Maximum

Minimum

Flow entering, lb/hr


Bypass quatity, lb/hr
Flow leaving, lb/hr
Hot air recirculation, lb/hr
Leakage, porcent

9 Temperature entering, F
10 Temperature leaving, F
(uncorrected)
11 Temperature leaving, F (corrected)
12 Mix temperature (after bypass), F
13 Pres. entering/leaving, in H2O gage
14 Pressure drop (allowable), in H2O
15 Pressure drop (calculated), in H2O
16 Heat exchanged, mm Btu/hr
17 Transfer rate (clean), Btu/hrft2F
18 MTD (uncorrected), F
19 Surface area, ft2
20 Tube side fluid
*21 Minimum allowable fire gas temp. F
22 Minimum metal temp. of flue gas side: allowable, F
23 Upper limit flue gas temperature, F

Minimum ambient air temp., F


Calculated , F

Utilities and Miscellaneous:


*24
*25
*26
*27
*28
29
30
31
32
33

Plant air pressure, psig


Steam: pressure, psig
Water: pressure, psig
Structural wind load, psi
Elevation, m above sea level
Other

Instrument air pressure, psig


Temperature, F
Temperature, F
Seismic factor
Relative humidity

Construction:
Regenerative type:
34 Horizontal shaft: Air inlet (left, right, above, below)
Vertical shaft: Air flow (up, down)
35 Internal air bypass (yes, no) and type of operator
36 Main drive
Baskets:
37 Cold end
38 Intermediate
39 Hot end

Auxiliary drive
Gage

Material

Depth (min)

Description

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI

FECHA

SEP.96

Pgina 24

Indice volumen

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page 9
of

Service
Unit
Type
Owner
Purchaser
Vendor
Date

FIRED HEATER DATA SHEET


CUSTOMARY UNITS

REVISION

Mechanical Design Conditions (continued)


Air Preheater Section (continue):
Construction (continued):
Recuperative Type:
1 No. of air passes
2 Description of surface

No. of tubes/air pass

3 Materials of construction
4 Intermediate air crossover duct: Included (yes, no)

With/without insulation

Bolted or welded
Heat Pipe:
5 Tube material
Outside diameter, in
6 Air side fins (solid/segmented): width, in
Thickness, in
7 Gas side fins (solid/segmented): Width, in
8 Thickness, in
9 Tubes per row
10 Effective length: Air side
11 Maximum allowable soaking temperature, F

No.
A.W./M.W., in
Height, in
Material

No. per inch

Height, in
No. per inch

Material

No. of rows

Square, triangular

Pitch
Flue gas side

Indirect Circulating Type:


12 Air heater coil: material
Outside diameter, in
13 Fin description

No.
A.W./M.W., in

14 Tubes per row


No. of rows
15 Expansion tank
Valves
Note: See fired heater section of data sheets for flue gas coil details

Effective length

Square, triangular

Pitch
Pumps

Other Type:
16
17
Accessories:
18 Soot blowers
19 Water wash
20 Fire extinguisher system
21 Controls
22 Insulation: external
23 Corrosion protection
24 Expansion provisions
25 External cold air bypass (yes/no)
26 External hot air recirculation (yes/no)

Internal

Damper operator type


Damper operator type

Forced Draft

Induced Draft

Fans:
27
28
29
30
31
32
33
34
35

Flow rate, lb/hr


Temperature, F
Static pressure, in H2O
Revolutions per minute
Maximum allowable fan speed, rpm
Manufacturer and arrangement
Type and size
Bearing type
Coupling type

Normal

Design

Normal

Design

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Para llenar el formato, haga click AQUI

FECHA

SEP.96

Pgina 25

Indice volumen

Indice norma

Equipment No.
Plant Location
No. Required
Reference No.
Reference No.
Reference No.
Page 10 of

Service
Unit
Type
Owner
Purchaser
Vendor
Date

FIRED HEATER DATA SHEET


CUSTOMARY UNITS

REVISION

Mechanical Design Conditions (continued)


Air Preheater Section (continued)
Construction (continued):

Fans (continued):
1
2
3
4

Forced Draft

Induced Draft

Casing materials of construction


Impeller materials of construction
Damper, type and location
Damper operator

5 Special requirements (noise limits, inlet screens, rain hoode, guide vanes, etc.)

Drivers:
Electric Motors:

Forced Draft

Induced Draft

Forced Draft

Induced Draft

Forced Draft

Induced Draft

6 Manufacrure and type


7 Horsepower
8 Voltage/nertz/phase
9 Revolutions per minute
*10
11
*12
13
*14

Enclosure
Insulation
Service factor
Bearings (type and tube)
Special requirements

Turbines:
15
16
17
18
19
20

Manufacturer and type or designation


Horsepower, desing condition
Horsepower, design condition
Water rate, normal condition, lb/hr/hp
Water rate, design condition, lb/hr/hp

Revolutions per minute, normal condition


21 Revolutions per minute, design condition
*22 Steam conditions, inlet
*23 Steam conditions, outlet
24 Governor
25 Bearings, type and tube
*26 Special requirements

Transmission:
27
28
*29
30
31
*32

Manufacturer and type


Ratio
Service factor
Lube system
Coupling manufacturer and type
Special requirements (clutches, coupling guards, etc.)

PROCEDIMIENTO DE INGENIERIA

PDVSA
.Men Principal

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA
Indice manual

Indice volumen

FIRED HEATERS
CHECKLIST
(FORMATO 3)

PDVSA LTP2.7
REVISION

FECHA

SEP.96

Pgina 26
Indice norma

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Indice volumen

REVISION

FECHA

SEP.96

Pgina 27
Indice norma

Para llenar el formato, haga click AQUI

FIRE HEATER CHECKLIST


This checklist is to be used for indicating specific requirements of the purchaser when the standard API 56095
provides a choice or designates that a decision must be made. These items are indicated by a bullet (*) in the
standard API 56095. This completed checklist shall be considered as part of this document.

Paragraph
1.6.2

Item

Requirement

Applicable local rules and regulations

1.7.1.3

Number of copies of referenced drawings and data required

1.7.2, 1.9

Noise data sheets provided

Yes

No

1.9

As built data sheets and drawings required

Yes

No

2.3.6

Corbels acceptable

Yes

No

Baffles acceptable

Yes

No

3.2.1

Acceptable extended surface type:


Studs

Yes

No

Solid fins

Yes

No

Segmented fins

Yes

No

3.2.3

Basis for extended surface dimensions

Gas

Oil

5.1.4

Inspection openings are required

Yes

No

Yes

No

If yes, terminal flanges are acceptable


5.1.6

Low point drains shall be furnished by vendor

Yes

No

High point vents shall be furnished by vendor

Yes

No

Yes
Yes

No
No

Yes

No

5.2

Alternative terminal loadings

6.3.2

Acceptable tube support corrosion protection:


Refractory coating
50Cr50Ni material

7.1.1

Alternate casing temperature design

7.4.5, 7.5.7

Specified internal protective coating

8.1.2, 9.2.2

Code requirements for wind and earthquake loads

8.1.5, 9.2.8

Alternate ambient conditions for structural design

8.2.5

Locations for future platforms, ladders, and stairways

8.2.7

Allowance for fireproofing

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Indice volumen

REVISION

FECHA

SEP.96

Pgina 28
Indice norma

Para llenar el formato, haga click AQUI


Paragraph
8.3.1.2

Item

Requirement

Header box closures:


Hinged doors
Bolted panels

8.4.4

Plataform decking requirements

8.5.2

Acceptable low temperature materials

9.1.11

Location of control dampers.

9.5.4

Acceptable strake design


Staggered plates

Yes

No

Yes

No

Yes

No

Yes

No

Spiral spoilers
9.6.1

Acceptable materials of construction:


Stacks
Ducts
Breechings

9.6.2

Acceptable bolting materials

10.1.4

Single burner with multiple guns is acceptable

Yes

No

10.1.5

Pilots for gas burners

Yes

No

10.2.1

Acceptable sootblower type:


Retractable

Yes

No

Rotaryautomatic

Yes

No

Rotarymanual

Yes

No

Stainless shrouds

Yes

No

Hightduty brick

Yes

No

Castable refractory

Yes

No

Open

Close

10.2.5

10.3.5

Acceptable erosion protection:

Acceptable bearings type


Type of cooling

10.4.1

Damper position on failure

11.1.3.4

Aditional flue gas sampling connections

11.2.1

Crossover thermowell connection required

Yes

No

11.2.2

Outlet thermowell connection required

Yes

No

11.3.3.2

Water washing is required:


Radiant

Yes

No

Convection

Yes

No

Galvanizing

Yes

No

Zinccoating

Yes

No

11.4

Tubeskin thermocouple requirements

12.1.1

Site receiving and handling limitations

12.2.5.1

Charpy impact test requirements

12.3.1

Unacceptable referenced welding processes

12.3.3

Unacceptable referenced purge gases

12.4.3

Acceptable bolt weather protection:

Root pass welding restrictions

PROCEDIMIENTO DE INGENIERIA

PDVSA

PDVSA LTP2.7

HORNOS DE PROCESO
REQUISICION, ANALISIS DE OFERTAS Y
DETALLES DE COMPRA

.Men Principal

Indice manual

Indice volumen

REVISION

FECHA

SEP.96

Pgina 29
Indice norma

Para llenar el formato, haga click AQUI

12.5.6.2

Acceptable castable curing method:


Yes

No

Water spray

Yes

No

Resin membrane

Yes

No

Yes

No

Air dry only

13.3.1.1

Prior approval of major defect repairs required


Criteria for rejection:

13.3.1.2

Radiograph examination requirements: