ROM ACI-Bullder Ver: 5.1.0.0 Project No: ane Project Name: ae ‘Job Title: B3_BESIDE STAIRS. Cols by: #88 Checkedby: __### Reinforced Concrete Members ACI-Builder [=.= ——r Dote: nor 2016 Calculation of Crack Width According to ACI 224R-01 Transformed Section + nAst / t es tex act « fe =—S— Steainn Stress-Forces 2xat: Depth of concrete in tension zone Material Properties: fo=32 Ma concrete compressive strength fy = 201 Bending Reinforcement vid strength Reif. medius of easticty Denaty of normal-weight conrste Ec = 4700 * sqrti('c) = 3059.43 MPa Concrete modulus of elasticity’ mes | €c= 85081 Modular Reto Section Properties: Section breadth Section height Cover to center of ccmpression bars Cover to center of tension bars Effective depth bars Number of tension bers 2 mn Diameter of tension bar Sram Bar spacing cfc Ast = 8732 = 6433.98 mm2 Area of tension steel Compression reinforcement: nc =3 bars umber of compression bars de = 25 mn Diameter oF comroression bar Asc = 3125 = 1472.62 mm rea of compression stee! Applied service moment: Ma =718 Him Applied Flexural service mement Section Properties at Cracking Stage: b= Blnast) = 0.00047 = [o-tyraseyfin ct] ~ 0.19402 C= sqrt (2 d.b(1 tr acid 4f14r}-2)14) Ht 305.27 mam Neutral axis depth Mement lever arm l= GHz Mement of inertia of ross concrete section (B.C"3/9)4n.Ast(dC)Z]4[(r-1)Asc(C-ac)“Z] = 14438606492.35 mm4 Moment of inertia of cracked concrete section fr = 62*sayt(Fe) — 4.02 MPa Concrete modulus of rupture er = Gi*Ig}(H2) = 216.98 kim Cracking moment ROM ACT-Builder (Reinforced Concrete Members ACI-Builder) Developed by: Eng. Hussein Rida ROM ACI-Bullder Ver: 5.1.0.0 Project No: ane Project Name: ae ‘Job Title: B3_BESIDE STAIRS. Caksby: ae Gheckedby: Reinforced Concrete Members ACI-Builder [=.= of Date: ‘07 2016 Calculation of Crack Width According to ACI 224R-01 Stress-Strain compatibility analysis characteristics: Ma * (4-0) Ter = Ma j (Ast #2) = 159.91 MPa = 0.381 Fy Steel tensile stress at service loadlevel la Cf fer = 15,18 NPa = 0,981 Fe ‘Concrete conpressive stress at service load level Calculacte of Crack Wid CLL e-3* PEs ia" at)%(H/3) = 0.221 mm Crack Width (Geraely-Lute Formule) Stoel tensile strace at service load love Depth factor Thickness of caver ta the center ofthe Fstlayer of tension steel bars at =210 nm Depth of the concrete areain tension zane determined by having the center of gravity o tension steel bas as the centriod ofthe concrete area in tension n= @ bars Number af steel bors a tendon sde (BFE) {nt = 10509 mm ‘ea of concrete in tension zone devided by the number of tension bars Check of maximum allowable crack width: Exposure condition: Humidity, moist air, soil ACI 224R-01 Table:4.1 Werkinax) = 0.3 mm Macmun crack wicth for selected exposure condtion Werk =0,221 mn < Werk-max = 0.3mm 0K Check of maximum allowable steel stress: f-mac= 170 MPa Macimun allowable sted stress - User Defined fs = 199.91 MPe < Femax= 170 MPa OK check of maximum bar diameter for highbond bars: fs = 159.91 MP2

You might also like