You are on page 1of 13

Working with Actix in practice

Module 2

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Content

Module 1
Getting started
Configuring Actix
Learning Actix

Module 3
Practical exercises /

Module 2
Working with Actix in
practice

Module 4
Advanced features

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

(Working with scanner and call trace


data)

Working with Actix in Practice


Need for process / process presentation

Site Verification
Cluster verification
Network verifiaction

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Pre-Launch Optimization
Pre-Launch Optimization is done when Network is built
and integrated, but there is no commercial traffic in it
In GSM coverage is an issue. In UMTS interferance is
critical
Realiability of equipement migh not be as good as in
GSM

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Standard process

SITE
VERIFICATION

CLUSTER
VERIFICATION

NETWORK
VERIFICATION

Efficiency and accuracy of analysis


Standard documentation big amount of data to be analyzed

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Global settings
Actix MainUser is in charge of defining:
Thresholds for map plots
Templates for measurement report forms
Many people in different regions using the same tool.
Process is needed

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Site Verification (1)

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Both scanner and tracer


measurements

Voice call is suitable to perform the


verification

Ec/Io should be in the range [-2 ;


-4]
Cross-feeders
external interference
SHO functionality

Site Verification (2)


Site should be the only one on air in the network
If not then at least only intra-site adjacences should be
defined in order to prevent the phone to perform handover
to other sites

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Site Verification (3)


Elements to be displayed on the map:
Scanner

RSCP per each SC

RSCP best server

Dominance plot

Ec/Io plot (interferance should be very low if only one site is on air)

Tracer

Display events on the measurement route (SHO, Drop call etc)

RSCP best server

Ec/Io plot

UE TX power

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Cluster Verification (1)

10

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Both scanner and tracer


measurements

Data call (high throughtput UL and


DL) to check performance

Cluster is 10 sites more or less

Critical issues are:


Pilot Pollution
Sectors having no dominance
Neighbour definition check

Cluster Verification (2)


Elements to be displayed on the map:
Scanner

RSCP best server

Dominance plot

Ec/Io plot (this should not be worse than -9 if there is no traffic in the NW

Tracer

11

Display events on the measurement route (SHO, Drop call etc)

RSCP best server

Ec/Io plot

UE TX power

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Cluster Verification (3)

12

When pilot pollution is detected documentation about overshooting


SC needs to be provided
RSCP of overshooting SC
Detailed plot of Ec/Io of polluted area

Same issue is for lack of dominance

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

Network Verification
Final stage
Problem should be fixed in the
two previous stages
Many measurement routes
which can be combined by
superstreaming

13

NOKIA Actix User Trainning/Module2.PPT / 01.08.2004 / NN

You might also like