You are on page 1of 1

Date:

Enquiry dated:
Project:
Quotation-no.:
Item:
Reference:
Evaporator (dx)
Capacity:
Surface reserve:
Air flow:
Air inlet:
Air outlet:
Air pressure:

0.85 kW
0.0 %
715 m/h
2.0 C
78 %
-0.9 C
93 %
1013 mbar

44 dB(A) in 3.0 m(2)


65 dB(A)
approx. 7 m(3)
0.0 mm

Noise pressure level:


Noise power level:
Air throw:
Frost:

Copper(6)
Aluminum(6)
-12.0 * 1.00 mm
12.0 * 1.00 mm
Art. 3, par. 3(8)

Tubes:
Fins:
Distr. press. drop:
Outlet connection:
Inlet connection:
PED classification:
C

GHF 020.2F/17-ANW50.E/A1

MTO

Page 1 of 1

R404A(1)
-5.0 C
5.0 K
40.0 C
34.7 C

Refrigerant:
Evaporation temp.:
Superheating:
Condensing temp.:
Subcooled temp.:

Casing:
AlMg3, Powder coated RAL 9003
Surface:
4.5 m
Tube volume:
1.9 l
Fin spacing:
7.00 mm
Dry weight:
14 kg(7)
Max. operating pressure: 32.0 bar
Dimensions:
F
A
D
L =
613 mm
B =
376 mm
H =
326 mm
E =
350 mm
F =
345 mm
C =
147 mm
A =
300 mm
D =
11 mm
K =
G

Unnamed

20605
Evaporator

GHF 020.2F/17-ANW50.E

Fans:
1 Piece(s) 1~230V 50Hz
Data per motor (nominal data):
Speed:
2400 min-1
Capacity (mech./el.): 0.04 kW/0.07 kW
Current:
0.32 A(4)
ErP:
Not relevant(5)

K
L

Drain according to DIN ISO 228-1 with G-thread (flat gasket).


Attention: Drawing and dimensions not valid for all accessory options!

GPC.EU Customer, 2013.01/2012-12-21, PL 1/2013

2013-01-29

Important remarks / explanatory notes:


(1)
(2)
(3)
(4)
(5)
(6)
(7)
(8)

Fluid group 2 according to pressure equipment directive 97/23/EG and directive 67/548/EWG
by using the enveloping surface method acc. to EN 13487
Distance at which an air velocity of 0.5 m/s can still be measured isothermally in an ideal space. The achievable penetration
depth of the air flow in the cold room depends on the spatial geometry and other factors.
The current consumption can differ in dependance of the air temperature and of the variations of system voltage according to
the VDE guidance.
This unit is equipped with fans that are not subject to Directive 2009/125/EC (ErP Directive), as power consumption at
optimum efficiency is lower than 125W.
The unit may not be suitable for very corrosive atmospheres (close to shores, in smoke rooms, etc.). For further information
see program menu "?", "Material recommendations brochure", or ask your sales partner.
Dimensions and weights are not valid for all possible options! They may differ for units with accessories or special units
(S-...).
Piping (DN = 10.0 mm, TSmax = 100 C, gaseous). Final classification according to pressure equipment directive 97/23/EC
during order processing.