Professional Documents
Culture Documents
+650/+655V
R7
121k/1W
VT3a
6SN7
C1
0.22u
650V
445V
R12
1k
R6
100k/1W
C7
20u/1200V
* Kiwame 2W / 1000V
VT4
KT88
218V
R2
511R
RCA
XLR
G
1
+
-
2
3
R1
100k
R3
2k
NE-2H
R23
2k
R21
100k
R22
511R
-255/-260V
R4
127k/1W
R24
127k/1W
SW3
R8
1k
VT1a
6SL7
R5
127k/1W
R11
33.2k/2W
R38
30.9R
R31
33.2k/2W
R48
30.9R
R29
2k
VT2b
6SN7
20u/630V
R28
1k
R44
10k
R32
1k
R49
10k
R54
10k
C2
0.22u
650V
VT6
KT88
R43
30.9R
OUT
(8ohm
SHOWN)
R53
30.9R
330R*
R50
R51
1k
330R*
R55
R47
100k/1W
RECOMMENDED COMPONENTS:
Resistors, Holco metal film;
H4 (1/2W, 1%) and H2 (1W, 1%)
Roerderstein Metal Film MK8 (2W, 2%)
unless stated otherwise.
Large capacitors, Solen or AEON film.
Small capacitors, Multicap PPFX.
Coupling capacitors, VTV "Ultra-Tone".
R56
32.4k
+650/+655V
VR1
25k
R58
100k
C3
0.22u
200V
VT7
KT88
R46
1k
VT3b
6SN7
SET-UP:
1/ Each bias potentiometer should be set initially at the
most negative end of the range. After 5 minutes warm-up
adjust each bias setting to 1.62V+/-0.01V (50mA).
2/ After 20 minutes warm-up with the amplifier 'right side up'
supply voltages should be adjusted to within the values shown
Re-adjust after a further hour.
3/ Now adjust each bias setting to 2.01V +/-0.01V for 65mA
(or to a value corresponding with the intended bias current.)
Note: With new tubes, the bias current can be expected to drift
significantly for the first 24-48 hours.
4/ Node voltages are given for diagnostic purposes
only and will vary with the individual tubes used.
R39
10k
R30
38.3k/2W
R27
121k/1W
R45
330R*
R41
1k
VT5
KT88
R37
100k/1W
+212V
C5
VT1b
6SL7
R40
330R*
R36
1k
VT2a
6SN7
R10
38.3k/2W
R25
127k/1W
R9
2k
C9
20u/630V
VR2
25k
R59
100k
R57
17.8k
C4
0.22u
200V
C11
5u
200V
-102V
Rev. C
6/7/2001