You are on page 1of 6

Applications

Mounting
Sealing
Ports
Filter Scanning
Installation

Type:

Construction:
Finish:
Filter frame:
Test socket DIN:

For filters:

Filters mounting :

Connection:

Pressure ports:

Performance:

Accessories:

Option:
FILTER SPECIFICATIONS
Rating
Type
Moc
Media
Handle
Temperature
Flow

FILTER SPECIFICATIONS
Rating
Type
Moc
Media
Handle
Temperature
Flow

CAMFIL
Exhaust of contaminated air (particles, microorganisms, molecules),
filter changing in secure plastic bag: Pharmaceutical,Biotechnology,
Chemistry, Hospitals, Biotechnology, Chemistry, Hospitals,
Laboratories biosafety, animalLaboratories biosafety, animal
facilities.

Modular system BIBO safe change housing to be assembled, fully


welded with test port integrated DIN 1946-4.
2mm steel airtight welded.
White epoxy painted baked RAL 9010 70m.
Continuous welded.
Integrated and controlled individually factory.
Filters 292mm depth particle Opakair, AbsoluteTM and carbon
Acticarb and 48mm depth Prefilters kind AeroPleat, EcoPleat,
MPleat.

Fast filter clamping by cam factory set, equipped with a "twice


security" both on clamping frame and door: impossible to clamp the
filter if not correctly positioned and impossible to close the door if
the filter is not clamped.

Rectangular flanges pre-drilled.


Locations provided upstream and downstream (pressure port kit to
be ordered separately).

Housing qualified +/- 6000Pa: Class 3 acc. to ISO10648-2, L1 acc. to


EN1886, Class D acc. to EN12237, Class C acc. to Eurovent 2/2. Max
penetration gasket frame at 600Pa:<0.01% by ISO14644-3.

Safe change bag with integrated o-ring sealable (FPA0466) Gaskets and bolting kit (FPA1108) - Connecting ducks 1-6 housing
in parallel for high flow rates (FPA1107) - Pressure test kit
(FPA0526)
Stainless steel, factory mounting full or partial, individual
factory tests with test report.

FREUDENBERG
Exhaust of contaminated air (particles, microorganisms,
molecules), filter changing in secure plastic bag:
Pharmaceutical,Biotechnology, Chemistry, Hospitals,
Biotechnology, Chemistry, Hospitals, Laboratories biosafety,
animalLaboratories biosafety, animal facilities.

: Inline to the Return Air Duct


: Cam Lock Arrangements , CAM MOC: SS304
: DOP Ports at Upstream for Hepa Filters
: Manual Hepa Filter Scaning Facility Will Be Provided With The
Help Of Glove And View Window..
: Both Ends are Flange End

H -13
99.95 %@MPPS
Box Type
Aluminium
Submicronic Glass Fibre Media
One No Handle On One Side
Ambient
610X610X305 MM
2000 CFM @25 MM OF WC

F -9
50 % Down to 0.3 Micron
Box Type
Aluminium
Submicronic Glass Fibre Media
One No Handle On One Side
Ambient
610X610X305 MM
2000 CFM @ 12-15 MM OF WC

You might also like