You are on page 1of 1

THIS DRAWING IS A

COPYRIGHT.

CONTENTS OF THE DRAWING OR PART THEREOF


MAY NOT BE USED OR REPRODUCED WITHOUT
THE PERMISSION OF

RAJKHOWAS AARCHI

M.D ROAD,CHANDMARI, GUWAHATI.

4
NOTES
PLINTH LEVEL

12000
6000

2995

1. ALL DIMENSIONS ARE IN M.M UNLESS

T.O.C. OF
PLINTH BEAM

3005

OTHERWISE SPECIFIED.
2. GRADE OF CONCRETE MIX SHALL BE M20
CONFORMING TO IS-456-2000. UNLESS

600

F.G.L.

OTHERWISE NOTED.

(CENTER-LINE LVL. OF
NEAREST ROAD)

CONFORMING TO IS-432-1960.
5. CLEAR COVER TO REINFORCEMENT:

B1

B2

B4

E.G.L.

C3

1750MM

C2

C4

50

800

8#@
100C/C
8#@
100C/C

4575

C1

6. DEVELOPMENT LENGTHS (IN MM.)

7. THIS DRAWING SHOULD BE READ IN CONJUNCTION

(LOWEST EXISTING
GRUND LEVEL)

BEAM = 25MM.
COLUMN = 40MM.
SLAB = 19MM.

WITH ALL OTHER ARCHITECTURAL AND STRUCTURAL

3150

T.O.C. OF
TIE BEAM

DRAWINGS.
8. RE-INFORCEMENT DETAIL IN COLUMN AS PER
IS-456-2000 & IS-13920
9. FINISH G.L. +0
10. S.B.C. OF SOIL SHOULD NOT BE LESS THAN 10T/SQ.M.

900

9150

8#@
125C/C

A4

1.2M(AVERAGE DEPTH)

A2

4575

A1

300

3. STEEL GRADE Fe500N/MM

T.O.C. OF PLINTH
BEAM 40MM DOWN
FROM PLINTH LEVEL

PLINTH LEVEL

50
F.G.L.
S.NO.

(CENTER-LINE LVL. OF
NEAREST ROAD)

DATE

REVISIONS

PLINTH BEAM

REVISIONS
d

100MM THK.
P.C.C(1:3:6)
75MM THK. FLAT
BRICK SOLING

REINFORCEMENT

T.O.C. OF
TIE BEAM

SECTION - A-A
SCHEDULE OF COLUMN
SL.

COLUMN NO.

NO.

REINFORCEMENT

TYP. SECTION

PROJECT
PROPOSED CONSTRUCTION OF
ADDITIONAL INFRASTRUCTURE
AT CISF TOWNSHIP

TIE BEAM

(LOWEST EXISTING
GRUND LEVEL)

400X350

400

4-16# +
4-12#

BAR

50

JOB NO.
SCALE
DEALT BY

CHECKED BY

50

CLIENT'S SIGN

D
150

d
100MM THK.
P.C.C(1:3:6)

80

C3

1750MM

BAR
80

QUARTER MASTER STORE

8#@ 75C/C

500

8-16#

500X350

8# AS DETAILED
IN COL. LONG &
CROSS SECTION

A1,A2,A4,B1,B2,B4,C1,C2,C4

350

2.

LINK

BRAHMAPUTRA CRACKER
AND POLYMER LIMITED

X-Y MM

350

1.

SIZE

E.G.L.

CLIENT

1.2M(AVERAGE DEPTH)

300

150

LAYOUT OF COLUMN & FOOTING

75MM THK. FLAT


BRICK SOLING

PLAN
TYPICAL DETAILS OF
ISOLATED FOOTING
SCHEDULE OF FOOTING
SL.

FOOTING NO.

NO.

ARCHITECT'S SIGN

TYPICAL ISOLATED FOOTING


ALONG WITH LONG SECTION OF
COLUMN
CONSULTANT

SIZE OF
FOOTING
X-Y MM

FOOTING REINFORCEMENT
X-DIR

TOTAL DEPTH

MIN. DEPTH
ARCHITECTS, ENGINEERS,

Y-DIR

VALUERS & PLANNERS


M.D.ROAD, CHANDMARI,

1.

A1,A4,C1

1700X1700

12#@125C/C

12#@125C/C

450

150

2.

C3

1800X1800

12#@125C/C

12#@125C/C

450

150

3.

A2,B1

1900X1900

12#@110C/C

12#@110C/C

500

150

4.

B2,B4,C2,C4

2000X2000

12#@110C/C

12#@110C/C

500

150

GUWAHATI- 781003

RAJKHOWAS
AARCHI

DRAWING TITLE
LAYOUT OF COLUMN & FOOTING

DRAWING NO.
RAA / CISF / Q. MASTER / T / ST- 01