9400 UX
LUX50
User Manual
3CC14295AGAA TQBJA 01
Status
Released
Change Note
2/374
3CC14295AGAA TQ BJA 01
with supervision
946LUX50
3CC14295AGAA TQ BJA 01
3/374
4/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
5/374
6/374
3CC14295AGAA TQ BJA 01
Table of contents
1 -- Foreword . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
13
13
14
14
14
15
16
18
19
21
21
21
22
24
28
28
2.2 -- Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.1 -- 1+0 configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.2 -- Basic 1+1 configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2.3 -- 1+1 configuration with multiplexer/demultiplexer protection . . . . . . . . . . . . . . . . . . .
30
30
34
36
38
39
39
40
41
42
42
44
45
45
47
48
49
51
59
3 -- Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
63
3.1 -- Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1.1 -- Checking the configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
63
63
64
68
70
3CC14295AGAA TQ BJA 01
7/374
3.3.1
3.3.2
3.3.3
3.3.4
-----
70
70
70
71
71
72
72
75
75
77
77
85
90
94
3.6 -- Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1 -- Wiring the power supply to the 19 indoor units . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.2 -- Equipment grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.3 -- IDU/ODU wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.4 -- Wiring the 34 Mbit/s tributary and auxiliary 2 Mbit/s stream . . . . . . . . . . . . . . . . . . .
3.6.5 -- Wiring n x 2 Mbit/s tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.6 -- Engineering service channel wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.7 -- Alarm and remote control wiring (TS/TC) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.8 -- Engineering service channel ESC2 telephone handset . . . . . . . . . . . . . . . . . . . . . .
99
99
100
102
104
104
106
107
107
108
108
109
111
111
111
113
114
114
115
115
115
140
141
141
141
141
144
145
145
145
145
4.5 -- NE Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
146
147
147
150
8/374
3CC14295AGAA TQ BJA 01
4.8 -- CONFIGURATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.1 -- NE Time . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.2 -- Network Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.3 -- Alarm Severities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.4 -- System Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.5 -- Quick Configuration Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.8.6 -- Profiles Management . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
154
154
155
163
168
172
187
4.9 -- EQUIPMENT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
192
201
201
204
4.11 -- RADIO
4.11.1 -4.11.2 -4.11.3 -4.11.4 -4.11.5 -4.11.6 --
......................................................................
Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Frequency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RTPC & ATPC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Power Measurement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
BER Measures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
205
206
206
207
208
210
215
216
216
217
4.13 -- SUPERVISION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.13.1 -- Access state (allow or inhibit NE Craft access) . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.13.2 -- Restart NE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.13.3 -- Software Feature key . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
218
218
219
220
221
222
225
229
4.15 -- LOOPBACKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.15.1 -- Available Loopbacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.15.2 -- How to activate a loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.15.3 -- How to remove a loopback . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
232
232
237
238
4.16 -- DIAGNOSIS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16.1 -- Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16.2 -- Log Browsing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16.3 -- Remote Inventory . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16.4 -- Abnormal Condition List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16.5 -- Summary Block Diagram View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.16.6 -- Current Configuration View . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
239
239
240
241
242
242
246
247
247
249
251
252
253
255
255
255
257
3CC14295AGAA TQ BJA 01
9/374
5 -- Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
261
261
262
262
263
263
263
265
265
265
266
266
267
267
267
267
268
269
269
271
271
271
271
271
272
272
272
273
273
273
274
275
7 -- Changing configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
277
279
279
279
280
280
280
289
290
291
294
294
294
295
295
10/374
3CC14295AGAA TQ BJA 01
295
296
296
297
298
300
300
300
301
301
303
312
314
314
314
315
315
317
318
318
319
319
320
321
322
323
323
323
325
325
326
328
329
329
331
333
335
335
335
335
335
336
337
339
339
340
343
3CC14295AGAA TQ BJA 01
11/374
344
344
345
346
346
347
348
A.6.1 -- Tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.6.1.1 -- 2 Mbit/s tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
A.6.1.2 -- 34 Mbit/s tributaries . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
349
349
349
351
351
351
351
355
355
355
356
356
356
357
359
361
A.9.1 -- Hardware . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
361
364
365
368
A.10.1 -- Software . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
368
A.10.2 -- Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
368
369
INDEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
371
12/374
3CC14295AGAA TQ BJA 01
1 -- Foreword
--
1.1
This manual is for users with a solid knowledge of how to operate and install microwave links and how to use
a PC-based craft terminal running the Windowst operating system. With this manual, you should quickly be
able to operate the equipment. This manual is not intended to replace the training services that we can provide
for your particular needs.
The manual is divided into seven chapters followed by appendixes and an Index.
1.2
--
Foreword
--
--
Installation
--
--
Commissioning
--
--
Changing configurations
--
Appendixes
--
Index
--
With this manual, you should be able to commission and operate the described equipment at a basic level.
You should always read this manual in conjunction with the attached Update document (if provided) so that
you are aware of the latest equipment upgrades.
Manual updates
This edition of the manual describes hardware and software releases of the revision indexes (and above),
detailed in Appendix 9.
In cases where an equipment upgrade affects the content of the manual, the relevant modification should be
inserted in the Update document, with the same reference number, but with code type VE (instead of TQ).
When the number or extent of the changes justifies it, they should be incorporated in the body of the manual
and the manuals revision index should be incremented.
Previous versions of this documentation release
Previous versions of this documentation are available on request
Note: MS-DOS, MICROSOFT and WINDOWS are registered trademarks of Microsoft Corporation.
3CC14295AGAA TQ BJA 01
13/374
1.3
--
Safety instructions
1.3.2 -- Symbols
1.3.2.1 -- Danger symbols
When subsystems and modules have warning labels, it is extremely important to follow their instructions.
These labels are designed to indicate dangerous situations; they may contain any standard symbol or any text
considered necessary to protect users and employees.
The most frequent danger situations and symbols are:
Danger or general warning
14/374
3CC14295AGAA TQ BJA 01
Emissions frequency: check that this complies with the standards in use in the country.
Radiation alert
--
1.3.3.1 -- Warning
--
protection of personnel,
--
--
--
protection of equipment,
--
--
--
--
1.3.3.2 -- Precautions
STOP
3CC14295AGAA TQ BJA 01
15/374
16/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
17/374
18/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
19/374
20/374
3CC14295AGAA TQ BJA 01
2.1
The Alcatel 9400 is a family of digital point--to--point microwave radio systems, designed to satisfy the various
digital transmission needs of public and private networks for a large range of applications.
The Alcatel 9400 UX family covers the frequency range from 11 to 38 GHz necessary to satisfy the largest range
of propagation conditions as well as network configurations that also provide a high spectrum efficiency from
11 up to 38 GHz band with a 16QAM version.
It provides the following capacities:
-- 2x2, 4x2, 8x2, 16x2 Mbit/s, 34 Mbit/s with the 4QAM modulation and 8x2, 16x2 Mbit/s, 34 Mbit/s with
16QAM modulation.
The Alcatel 9400 UX family is used worldwide in:
-- cellular networks,
--
fixed access networks for Public Telecom or CLECs (Competitive Local Exchange Carrier), including:
S
S
--
private networks,
--
from a few hundred meters up to 10 km for the millimeter wave frequencies (23 to 38 GHz).
Band
(GHz)
Frequency
(GHz)
ETSI Standard
Frequency plans
9413 UX
4QAM
13
12.75--13.25
EN 301 128
ERC 12--02
ITU--R Rec F497--7
266
9413 UX
16QAM
13
12.75--13.25
EN 301 128
ERC 12--02
ITU--R Rec F497--7
266
9415 UX
4QAM
15
14.4--15.35
EN 301 128
ERC 12--07
ITU--R Rec F636--3
9415 UX
16QAM
15
14,4--15,35
EN 301 128
ERC 12--07
ITU--R Rec F636--3
9418 UX
4QAM
18
17.7--19.7
EN 301 128
ERC 12--03
ITU--R Rec F595--8
9418 UX
16QAM
18
17,7--19,7
EN 301 128
ERC 12--03
ITU--R Rec F595--8
9423 UX
4QAM
23
21.2--23.6
EN 300 198
3CC14295AGAA TQ BJA 01
Duplex difference
(MHz) *
21/374
Designation
Band
(GHz)
Frequency
(GHz)
9423 UX
16QAM
23
21.2--23.6
EN 300 198
9425 UX
4QAM
25
24.5--26.52
EN 300 431
Class 1
1008
9425 UX
16QAM
25
24.5--26.52
EN 300 431
Class 4
1008
9438 UX
4QAM
38
37--39.5
EN 300 197
ERC 12--01
ITU--R Rec F749--2
1260
9438 UX
16QAM
38
37--39.5
EN 300 197
ERC 12--01
ITU--R Rec F749--2
1260
ETSI Standard
Frequency plans
Duplex difference
(MHz) *
1008, 1197, 1200,
1232
(Mbit/s)
2x2
4x2
8x2
16x2
34+2
RF channeling
(4QAM modulation)
(MHz)
3.5
14
28
RF channeling
(16QAM modulation)
(MHz)
--
--
14
2.1.2 - Configuration
2.1.2.1 -- Unprotected configuration
An Alcatel 9400 UX unprotected (1+0) radio terminal is made up of the following elements:
-- an Outdoor Unit (ODU): incorporating the complete RF transceiver (modem, RF units, branching filter)
and an integrated or separated antenna.The ODU is capacity independent,
--
an Indoor Unit (IDU): incorporating the baseband processing and offering tributary interfaces as well
as service channels and supervision.
22/374
a classic version allowing all possible configurations (1+0, 1+1, capacity up to 16x2 or 34 +2 Mbit/s).
3CC14295AGAA TQ BJA 01
These two IDU versions are compatible with a same ODU and can be mixed in the same network.
-- a single coaxial cable of a length which can be up to 300 m.
to improve the performances of the equipment towards propagation problem (in some outdoor unit
configurations only).
ODU CONFIGURATION
9400 UX
1+0
1x ODU
1x antenna single
polarization
Non--protected
1+1 HSB
2x ODU at same
frequency
1x coupler
1x antenna single
polarization
1+1 HSB SD
2x ODU at same
frequency
2x antenna single
polarization
Improvement of
performance versus
multipath propagation
1+1 FD
2x ODU at different
frequencies
2x antenna single
polarization (or 1 antenna
dual polarization)
Improvement of
performance versus
multipath propagation
3CC14295AGAA TQ BJA 01
23/374
The above mentioned outdoor unit configurations must be associated with one of the following indoor unit
configurations:
IDU CONFIGURATION
APPLICATIONS
1+0
classic IDU
Light IDU
Non--protected
1+0 EXT
classic IDU
Light IDU
Non--protected
1+1 BASIC
PROTECTION
Automatic switching:
selection of the best
receive path and
operational transmitter (in
case of HSB)
MAIN IDU
EXTENSION IDU (with
MUX option)
ACCESS IDU (34 Mbit/s
only
Automatic switching:
selection of the best
receive path and
operational transmitter (in
case of HSB)
Possible to insert
dedicated service channel
extension cards.
24/374
3CC14295AGAA TQ BJA 01
--
--
for the 13 GHz 4QAM (3CC11737Axxx) and the 16QAM (3CC 11736Axxx), a software transmission
power control of 20 dB in 1 dB step can be provided (as a software features key option with classic IDU,
embedded within the Light IDU)
--
for the 15 GHz 4QAM (3CC12979Axxx), a software transmission power control of 30 dB in 1 dB step
can be provided (as a software features key option with classic IDU, embedded within the Light IDU)
--
in the millimetric frequency bands (23 to 38 GHz), a software transmission power control of 30 dB in
1 dB step for the 4QAM and of 20 dB in a 1 dB step for the 16 QAM, can be provided (as a software
features key option with classic IDU; embedded within the Light IDU).
--
for all new generation ODU (ref. A9400 UX flat ODU) frequency bands for the 4 or 16QAM, the software
power transmission control of 30 dB in 1db step can be provided with the software features key.
--
--
set--up of transmission frequency range (7 to 40 GHz by default but configurable upon customer specific
request),
--
authorization for Transmit Power Control option (all bands except 18 GHz),
--
The Light IDU features a fixed embedded configuration (no removable software features key):
-- maximum configuration: 1+0,
--
--
3CC14295AGAA TQ BJA 01
25/374
The Outdoor Unit (1 or 2 depending on the configuration 1+0 or 1+1) can be rapidly installed on suitable poles
with their own fastening system.
The specific pole mounting is equipped with an accurate alignment system -- presetting and fine elevation and
bearing tuning -- to permit easy pointing with the integrated antenna. A very compact pole mounting has been
optimized for 1+0 configuration, it is common to 9400UX from 13 to 38 GHz.
The 9400 UX outdoor unit can be used with an integrated antenna 300 or 600 mm diameter or separate
antennas if a larger diameter is needed.
The ODU is fixed by means of quick latches. This system allows you to change the ODU without altering the
antenna alignment.
Two ODU generations are available. The new generation ODU, A9400 UX flat ODU, is lighter than the previous
range from 94xxUXR201 to 94xxUXR203*. It is 4 and 16QAM compatible and software configurable only.
* xx is for the band frequency of the Outdoor unit. For example, a unit referenced 9413UXR204 depends on the
13GHz frequency band
26/374
3CC14295AGAA TQ BJA 01
Simple commissioning:
All the standard Site Acceptance Tests can be done with a single PC to commission the link, making extensive
use of built--in supervision features:
-- continuous performance check and alarm status overview,
--
--
The transmission side incorporates a built--in PRBS (Pseudo Random Bit Sequence) generator able to insert
a standard test signal for the link Bit Error Rate measurements, in order to facilitate initial turn--on. The PRBS
can be switched on remotely.
2.1.3.3 -- Equipment software features
The Alcatel 9400 UX terminal provides a F interface to a Craft Terminal (PC), which enables alarm monitoring,
quality measurement, and configuration of the equipment.
The Alcatel 9400 UX Network Element (NE) supports a basic group of applications, listed hereafter, which
provide simplified testing, operation and maintenance of the equipment:
-- Installation and Operation parameters:
S
--
--
S
S
The software displays a synthesis of the monitored alarms (which are also available via dry loops).
The remote inventory is used to read the information allowing a complete identification of the
selected Network Element (Indoor Unit and Outdoor Unit): serial number, date of manufacture,
reference and revision index of the hardware and software releases.
Maintenance Memory:
S
--
Link quality monitoring : Background Block Errors, Errored Seconds, Severely Errored Seconds,
Unavailable Seconds.
Remote inventory:
--
S
--
Configuration of: capacity, Link Identity Code, Tx & Rx frequencies, output power (if available
through software),
The maintenance memory application allows the display of the last dated alarms stored in the
equipment when the Craft Terminal is not connected.
Power measurements:
This application is used to take measurements on various measurement points and displays them
on the screen: min Rx power, current Rx power, etc..
3CC14295AGAA TQ BJA 01
27/374
on the type of line interface units (LAU and LIU) installed in the IDU(s),
--
The table below summarizes the capabilities according to the bit rates supported by the IDU of the equipment
and the type of software features key used.
BIT RATES SUPPORTED BY SOFTWARE FEATURES KEY
IDU TYPE
4x2
8x2
2x2
4x2
8x2
16x2
2x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
2x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
8x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
8x2 Mbit/s
2x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
8x2 Mbit/s
2x2 Mbit/s
4x2 Mbit/s
8x2 Mbit/s
16x2 Mbit/s
--
--
--
16 x 2
34
34 Mbit/s + 2
Mbit/s auxiliary
2x2 Mbit/s,
--
4x2 Mbit/s.
1+0 configuration
integrated antenna
28/374
3CC14295AGAA TQ BJA 01
or
The block diagrams representing the main configurations appear in Figures 6 to 10 on the following pages.
3CC14295AGAA TQ BJA 01
29/374
--
2.2
Operation
--
OUTDOOR UNIT
Power supply
Modem
IF
block
Local loop
Tributaries
1 to 16
One 2 Mbit/s aux.
bit stream
(only at 34 Mbit/s)
Tributary interface
(LIU)
Tributary ports
(LAU)
Feature
key
Cable
Cable
interface
RF
equip.
Antenna
Attenuator
Power supply
unit
EXT
Service
kit
F Tel.
Back to TS/TC
back alarms
NMS
ESC
(Supervision
3/4/5
bus)
Alcatel or
Customer
OS
(SNMP)
INDOOR UNIT
DC
Tributaries
1 to 4
Power supply
OUTDOOR UNIT
Tributary ports
Tributary interface
TS/TC
NMS
(Supervision alarms
bus)
Modem &
Monitoring
Cable
Cable
interface
Light
Service kit
ESC3
Alcatel or
Customer
OS
IF
block
RF
equip.
Local loop
Attenuator
Antenna
Power supply
unit
(SNMP)
30/374
3CC14295AGAA TQ BJA 01
2.2.1.1 -- Operation of the main IDU (InDoor Unit) (classic IDU version)
The Line Access Units (LAU) offer all the passive functions required to provide transmission and reception
G.703 interfaces for the tributaries and 2 Mbit/s auxiliary bit stream (when there is one). This mainly entails
impedance matching. Two types of board can be used:
-- LAU 3CC06059Axxx: eight ports for 2 Mbit/s tributaries (two boards of this type are used for the
16 x 2 Mbit/s configuration),
--
LAU 3CC06061Axxx: one port for 34 Mbit/s + one 2 Mbit/s auxiliary bit stream port.
The LIU (Line Interface Unit) boards provide all the active functions required for transmission and reception
mode G.703 interfacing of tributaries and the 2 Mbit/s auxiliary bit stream (mainly HDB3 { HCMOS code
conversion). The LIU boards are daughter boards that plug into the MCU board. Three types of board can be
used:
-- LIU 3CC05818Axxx: four ports for 2 Mbit/s tributaries,
--
--
LIU 3CC06119Axxx: eight port extension unit, used in conjunction with the eight port LIU board,
3CC06026Axxx, for the 16 x 2 Mbit/s configuration,
--
LIU 3CC06118AAxx: one port for 34 Mbit/s + one 2 Mbit/s auxiliary bit stream port.
dropping/insertion of engineering service channels (up to 5) and the 2 Mbit/s auxiliary bit stream (when
there is one):
ESC N_4 and N_5: V.11 64 kbit/s interfaces (not available for the 2 x 2 Mbit/s rate),
--
--
--
--
--
telephone ESC transmission and reception between the IDU and the ODU,
The Power Supply Unit (PSU) is available in two versions, 24 V or 48 V DC floating, for primary power supplies.
It provides DC/DC conversion to generate the necessary voltages required to operate the indoor unit and the
primary power supply voltage of the outdoor unit.
3CC14295AGAA TQ BJA 01
31/374
--
--
connection of local supervision system, for connecting a supervision PC. To operate the LUX50
software, additional SIMM memory must be added (option sold by reference 9400UXB267).
--
--
--
For the Light IDU, the types of power supply available are:
S 19 Light IDU: 24 V DC or 48 V DC floating (This version is a low power consumption version,
allowing the operation of the Light IDU without fans).
2.2.1.3 -- IDU/ODU cable
A coaxial cable, only available in 50 ohm impedance version, with a maximum length of 300 meters (when of
standard type), connects the IDU to the ODU. This carries:
-- the digital data streams between the IDU and the ODU, comprising:
--
32/374
in the case of a classic IDU, the IDU/ODU telephone channel (connected to ESC N_2).
3CC14295AGAA TQ BJA 01
separation of the signals and the power supply voltage to feed the units subsystems,
--
the interface for the aggregate for transmission or reception with the modem.
The Modem (modulator/demodulator) function receives the aggregate from the cable interface and processes
the baseband signal for microwave transmission by 4QAM or 16QAM modulation, as follows:
-- in transmission:
--
in reception:
analogue/digital conversion of the I and Q bit streams from the demodulation function.
It interfaces with the IF unit for the transmission and reception of the I and Q bit streams.
The IF block handles modulation and demodulation of the aggregate, using the following functions:
-- in transmission:
--
analogue filtering of the I and Q bit streams (two filters that can be switched according to capacity),
4QAM or 16QAM modulation of an IF carrier, according to the frequency plan adopted, generated
by a local internal oscillator,
level amplification and tuning (AGC), based on measurement of the rms power output from the
block;
in reception:
amplification, with AGC, of the received signal, transposed via the reception system according to
the frequency plan adopted,
demodulation of the signal, so that the I and Q bit streams can be recovered,
amplification and analogue filtering of the bit streams (two filters that can be switched according
to capacity),
amplification, with AGC, before transmission of the I and Q bit streams to the Modem board.
The transmission mixer transposes the intermediate frequency to a microwave frequency. Frequency agility
is obtained by a synthesized local oscillator (LO).
The transmission RF signal is then transmitted to the power amplifier, monitored by an output power slaving
device and a circuit for cutting off carrier transmission if a fault is detected in the transmission circuits.
3CC14295AGAA TQ BJA 01
33/374
For the 13 GHz and the 23 to 38 GHz frequency bands, the transmitted power can be adjusted in 1 dB steps
by software configuration (software key option needed), within a range of:
-- --20 dB from nominal output power for 13 GHz (94xxUXR202 and 94xxUXR203),
--
--30 dB from nominal output power for 15, 23, 25, 38 GHz (4QAM RTPC),
--
--20 dB from nominal output power for 23, 25, 38 GHz (94xxUXR203 16QAM).
--
--30 dB from nominal output power for all frequency bands of the ODU 9400UX flat ODU.
For the 11, 13, 15 and 18 GHz frequency bands (without RTPC option), attenuators can be inserted on the
transmission output (optional).
The reception RF signal from the branching filter is applied to the RF reception circuit, comprising a cascaded
RF low noise amplifier (except at 38 GHz), a mixer and an IF amplifier. The mixer, which receives the amplified
RF frequency, transposes the RF signal to a reception IF signal using the same LO as the transmission mixer.
When amplified, the signal is sent to the IF blocks reception circuits for demodulation.
The branching filter comprises a duplexed filter for separating the transmission and reception RF signals
present at the antenna port. It can accommodate the RF loopback (94xxUXR201, 94xxUXR202 and
94xxUXR203, and included into A9400UX flat ODU), which uses a conversion stage for converting transmission
and reception frequencies for test purposes.
The PSU receives the primary voltage from the IDU via the link cable and, from it, generates the voltages
required to operate the subsystems of the Outdoor unit.
2.2.1.5 -- ESC extension configuration
This extension, available only in the classic IDU version, can be used to customize ESC N_3 and N_4 and
5 as detailed in 2.3. It requires the presence of an extension IDU with a dedicated SCU (Service Channel Unit)
board.
--
The MCU of the main unit sends the aggregate to be transmitted to the SCU and receives the reception
aggregate from it. The MCU is responsible, in reception, for switching between the normal and standby
channels.
There are three configurations:
-- Hot Standby (HSB), one antenna port
--
--
Frequency diversity.
34/374
3CC14295AGAA TQ BJA 01
DC
Tributaries
1 to 16
OUTDOOR
UNIT
Cable
Back
to
back
TS/TC
alarms
To
coupler
or
Antenna
Service
kit
ESC EXT
3/4/5
Alcatel or
Customer
OS
(SNMP)
DC
EOW3
EOW4
OUTDOOR
UNIT
Cable
EOW5
To
coupler
or
Antenna
Service
kit
cut off for the ODU which permits the output power control.
The HSB switching of a transmitter is based on detection of a fault which can originate from a failure:
-- of the cable interface,
--
--
--
of the RF synthesizer,
--
of the amplifier.
The system switches back to the normal channel automatically as soon as it is disconnected and reconnected
again without alarm (because of imbalance in the system), in transmission and in reception.
Switching can also be remotely controlled, by manually switching to the standby channel. The remote control
for cutting off transmission power does not cause a switchover.
2.2.2.2 -- HSB configuration with two antenna ports
This configuration uses either a double polarization antenna or two antennas (in this case, it also adds space
diversity). One system sends (the standby transmitter is cut off). Operation is the same as in the previous
configuration, apart from the switching, in which reversibility is not required because the link budgets are
identical for both channels.
2.2.2.3 -- Frequency diversity configuration
The two ODUs send the aggregate simultaneously at two different frequencies. The MCU chooses the best of
the two signals on reception. This configuration also uses two antenna ports.
3CC14295AGAA TQ BJA 01
35/374
an extension IDU.
--
--
two ODUs.
DC
MAIN INDOOR UNIT
Tributaries
1 to 16
Cable
OUTDOOR
UNIT
2 Mbit/s aux.
(only at 34
Mbit/s)
Feature
key F
Tributaries 1 to 16
Tel.
Back to TS/TC
back alarms
NMS
(Supervision
bus)
To
coupler
or
Antenna
Service
kit
VDS EXT
3/4/5
Alcatel or
Customer
OS
(SNMP)
DC
Tributaries
1 16
Cable
OUTDOOR
UNIT
To
coupler
or
Antenna
2 Mbit/s aux.
(only at 34
Mbit/s)
EOW3
EOW4
EOW5
Service
kit
Figure 9 - Block diagram of a 1+1 station with multiplexer protection without access unit
36/374
3CC14295AGAA TQ BJA 01
DC
MAIN INDOOR UNIT
Tributaries
1 to 16
ACCESS
INDOOR
UNIT
Cable
OUTDOOR
UNIT
2 Mbit/s
auxiliary (only at
34 Mbit/s)
Feature
F Tel.
key
Tributaries
1 to 16
2 Mbit/s
auxiliary bit
stream
(only at 34
Mbit/s)
Back to TS/TC
NMS back alarms
(Supervision
bus)
To
coupler
or
Antenna
Service
kit
ESC EXT
3/4/5
Alcatel or
Customer
OS
(SNMP)
DC
Tributaries
1 to 16
Cable
OUTDOOR
UNIT
To
coupler
or
Antenna
2 Mbit/s auxiliary
(only at 34 Mbit/s
EOW3
EOW4
EOW5
Service
kit
--
--
--
The MCU boards of the main IDU and the SCU board of the extension IDU exchange the aggregates sent and
received.
The access IDU contains a dedicated LAU combination board which handles:
-- in transmission, distribution of the tributary signals to the main and extension IDUs,
--
All the basic 1+1 configurations are also available in 1+1 configurations with multiplexer protection (refer to
2.2.2.1 to 2.2.2.3).
3CC14295AGAA TQ BJA 01
37/374
--
2.3
in the Light IDU configuration: two engineering service channels (ESC N_1 and ESC N_3).
In the main classic IDU and in the Light IDU, the characteristics of these engineering service channels are
predefined.
The extension IDU (classic IDU version) can be used to customize ESC N_3, N_4 and N_5. This unit has a SCU
board installed with daughter boards to customize ESC N_3 and N_4.
The table below summarizes the ESC options available according to whether the configuration includes a main
IDU (classic, Light) or a classic main IDU with an extension IDU.
ESC
1+0 CONFIGURATION
WITH Light IDU
ESC N_1
Supervision
Supervision
Supervision (1)
ESC N_2
ESC N_4
(Bit rate
> 2x2 Mbit/s)
As ESC N_ 3 (3)
ESC N_5
(Bit rate
> 2x2 Mbit/s)
38/374
3CC14295AGAA TQ BJA 01
NMS1
NMS2
STATION B
TERMINAL B1
NMS1
STATION C
TERMINAL B2
NMS2
NMS1
NMS2
cable
3CC07711AAxx
9400UXC332
cable
3CC07711AAxx
9400UXC332
NMS1
NMS2
STATION D
TERMINAL B3
NMS1
TERMINAL C1
NMS2
TERMINAL D1
NMS1
NMS2
NMS2
Routing
NMS1
Radio
MSU1
Each port is enabled or disabled in the system software (IP Configuration(see 4.8.2.3): MSU1 radio
inputs/outputs, NMS1 and NMS2 cables.
Supervision
With
946LUX50
software
NMS1 NMS2
in analogue form, at the AUDIO 1 and AUDIO 2 connectors of the main IDU, for setting up a
point-to-multipoint link,
3CC14295AGAA TQ BJA 01
39/374
STATION A
BACK TO BACK
TERMINAL A2
TERMINAL B1
BACK TO BACK
Digital link
cable 3CC08729AAxx
9400UXC333
TERMINAL B2
BACK TO BACK
AUDIO 1
Analogue link
cable 3CC07711AAxx
9400UXC332
TERMINAL A1
STATION B
AUDIO 2
BACK TO BACK
Digital link
cable 3CC08729AAxx
9400UXC333
TERMINAL B3
AUDIO 1
STATION C
TERMINAL C1
AUDIO 2
ESC N_4 is a V11 point-to-point 64 kbit/s channel (not applicable to the Light IDU versions).
The V11 or V28 equipment connects to the ESC. EXT. connector of the main IDU.
2.3.3.2 -- With extension IDU (not applicable to the Light IDU versions)
With an extension IDU, the ESCs can be digital (G.703 or V11/V28 64 kbit/s, V11 or V28 9.6 or 4.8 kbit/s) or
analogue (four-wire telephone channel + TTL interface of RON/TRON type), point-to-point or
point-to-multipoint. The ESCs are customized by daughter boards described in 7.9.
POINT-TO-POINT ESC
Connection for the ESC equipment:
-- ESC N_3: to the ESC 3-1 connector of the extension IDU.
--
Connection of two terminals back-to-back: each of the terminals must have an extension IDU with an ESC board
of the same type. The link is set up by a cable linking ports ESC 3-1 (ESC N_3) and ESC4-1 (ESC N_4) on
the extension IDUs of the two terminals.
40/374
3CC14295AGAA TQ BJA 01
POINT-TO-MULTIPOINT ESC
This type of ESC can be used only for asynchronous digital links.
Connection for the ESC equipment:
-- ESC N_3: to connectors ESC 3-1 and ESC3-2 of the extension IDU,
--
ESC N_4: to connectors ESC 4-1 and ESC4-2 of the extension IDU.
The connection of the terminals for ESC N_3 is illustrated in Figure 14. The connection principles are the same
for ESC N_4, replacing ESC 3-1 with ESC 4-1 and ESC 3-2 with ESC 4-2.
STATION B
STATION A
TERMINAL A1
MAIN
IDU
ESC. EXT.
3CC07157AAxx
9400UCX130
ESC. MAIN
TERMINAL B1
TERMINAL B2
MAIN
IDU
MAIN
IDU
ESC. EXT.
3CC07157AAxx
9400UCX130
ESC. MAIN
ESC EXT.
ESC 3-1
ESC. EXT.
3CC07157AAxx
9400UCX130
ESC. MAIN
ESC EXT.
ESC EXT.
STATION C
TERMINAL C1
MAIN
IDU
ESC. EXT.
3CC07157AAxx
9400UCX130
ESC. MAIN
ESC EXT.
ESC 3-1
Baseband link
cable 3CC07711AAxx
9400UXC332
ASYNC.
V.28 EQUIP.
ASYNC.
V.28 EQUIP.
STATION D
TERMINAL D1
Baseband link
Cable 3CC07711AAxx
9400UXC332
TERMINAL B3
MAIN
IDU
ESC. EXT.
3CC07157AAxx
9400UCX130
ESC. MAIN
MAIN
IDU
ESC. EXT.
3CC07157AAxx
9400UCX130
ESC. MAIN
ESC EXT.
ESC 3-1 ESC 3-2
ESC EXT.
ESC 3-1
ASYNC.
V.28 EQUIP.
3CC14295AGAA TQ BJA 01
41/374
--
2.4
The loop formed by the common and normally closed contacts is normally closed (in the
absence of an alarm condition or remote control).
eight housekeeping alarms (remote indications via dry loops), available to the user. The remote
indication loops are configured as normally open and can be configured as normally closed, depending
on the setting of the swaps on the MCU board, as described in 7.10.1. A name can be assigned to
each loop, in the software, on installation. These loops are available:
--
EQUIPMENT
Relay position in the
absence of an alarm
condition or remote
control
Normally open
Common
Normally closed
0.5 A / 100 V
dry loops
EQUIPMENT
CHOICE
Housekeeping loop
normally closed (in the
absence of an alarm)
REMOTE CONTROL
AND ALARMS
REMOTE INDICATIONS
--
2.5
Loopback options
The loopback options are provided on the active channel to facilitate commissioning and maintenance
operations. Figure 16 shows the positioning of the loops according to the configuration.
Each local loop loops the aggregate:
--
--
at the input of the main ODU | and the extension ODU ~, to check the cable link between the IDU
and the ODU (this command cuts off output power),
--
at the output of the main ODU } and the extension ODU if the RF loopback option has been
selected (the RF loop cuts transmission).
42/374
CAUTION:
S A local loop disconnects the link and isolates it from the network.
S The RF loopback configuration requires the remote transmitter to be cut off.
3CC14295AGAA TQ BJA 01
2
Aggregate
MUX
To antenna
ODU
IDU PRINCIPAL
Tributaries
1
1+0 CONFIGURATION (classic IDU, Light IDU)
2
Aggregate
MUX
To antenna
To antenna
ODU 1
IDU PRINCIPAL
Tributaries
1
4
Aggregate
EXTENSION IDU
ODU X
To antenna
To antenna
To antenna
To antenna
ODU 1
1
4
Active MUX
Aggregate
Tributaries
ODU X
EXTENSION IDU
MUX
Inactive MUX
BASIC HSB 1+1 CONFIGURATION WITH MULTIPLEXER PROTECTION (classic IDU) without access unit
2
Aggregate
MAIN IDU
MUX
ACCESS IDU
ODU 1
1
4
Active MUX
Aggregate
Tributaries
ODU X
EXTENSION IDU
MUX
Inactive MUX
BASIC 1+1 HSB CONFIGURATION WITH MULTIPLEXER PROTECTION (classic IDU)
3CC14295AGAA TQ BJA 01
43/374
MAIN IDU
ODU
ODU
MAIN IDU
BER analyzer
Remote
loopback
Remote station
Local station
The remote loop remote control function must be executed on the remote station.
Remote loopback can be used in a stations IDU to loop the receive output of a tributary to its transmit input.
This way, you can use a BER analyzer connected to the local station to check out a hop (Figure 17).
--
2.6
S Before setting up a loop, you must assign identical link identity codes for both
transmit and receive directions to avoid generating an alarm condition.
Equipment management
After installing and commissioning the equipment, the configuration parameters (bit rate, frequency, power, etc.)
are saved in the equipment.
The configuration is saved in two memories, one located in the IDU, the other in the ODU.
On power up, the microprocessor responsible for administering the equipment compares the content of the two
memories:
-- if the contents are identical, it loads their content into the various modules of the IDU and the ODU, and
switches the equipment to operational mode,
--
The default configuration is obtained by attempting to load the configuration of equipment that is not included
(for example, disconnect the ODU, power up the IDU and choose to download the ODU configuration when the
LEDs are flashing at the same time). You must then reload the entire equipment configuration from the CT.
Note : When the IDU and ODU leds are off, then the equipment starts automatically in default
configuration.
44/374
3CC14295AGAA TQ BJA 01
--
2.7
The indoor units have a Connector panel and an Operation panel (Figure 18). The operation panel carries
controls and indicators which duplicate those on the Connector side. The tables in the sections that follow
describe these components.
In some configurations, some of the items described below may be omitted.
--
connectors.
TYPE
FUNCTION
Red LED
Yellow LED
Yellow LED
Green LED
Green LED
ON/OFF
Two-position
switch
RST
Pushbutton
IDU-ACO/ODU
3CC14295AGAA TQ BJA 01
45/374
ITEM
I/O (1/8)*
I/O (9-16)*
DC 24V-48V *
TYPE
Female
37-pin sub-D
connectors
Male
3-pin sub-D
connector
RJ11
connector
FUNCTION
2 Mbit/s port version:
Tributaries 1 to 16.
34 Mbit/s port version:
34 Mbit/s ports on 1.6/5.6 coaxial sockets mounted on a plate
installed in place of the top I/O (9/16) connector.
Primary power supply input (24 V or 48 V DC).
ESC telephone handset port.
AUDIO 1 *
AUDIO 2 *
Female
9-pin sub-D
connector
ESC. EXT. *
Female
37-pin sub-D
connector
ALARM. I/O *
Female
25-pin sub-D
connector
NMS 1 *
NMS 2 *
Female
9-pin sub-D
connector
F*
Female
9-pin sub-D
connector
Female
9-pin sub-D
connector
S Connector for the software feature key according to the configuration, enabling the equipment to operate (must be fitted).
S Also used for maintenance (factory tests).
SKU/MTN
EXT
Female
68-pin mini-D
connector
BACK TO BACK
Female
50-pin mini-D
connector
ODU
Female N
connector
Link with the ODU. This connector includes a protective spark gap.
46/374
3CC14295AGAA TQ BJA 01
display components for ascertaining the operational state of the equipment at a glance,
--
connector ports.
TYPE
FUNCTION
ODU
Female N
connector
Link with the ODU. This connector includes a protective surge arrestor.
Red LED
Red LED
Yellow LED
Yellow LED
Green LED
Green LED
Female 9--pin
Sub--D connector
Female 9--pin
Sub--D connectors
I/O 1-4 *
Female 37--pin
Sub--D connector
Tributaries 1 to 4
ESC 3 /
ALARM I/O *
Female 37--pin
Sub--D connector
S ESC N 3 interface
S Remote controls and telesignalling (TS/TC)
F*
NMS 1 *
NMS 2 *
Momentary action
two--position switch
lost
RST
Pushbutton
Software reset.
DC 48V or 24V *
ON/OFF
Stable two--position
switch
3CC14295AGAA TQ BJA 01
47/374
connectors.
In the first three columns of the table below, a cross indicates the presence of the components according to the
type of extension unit:
-- Type A : ESC extension unit.
--
--
A B C
ITEM
TYPE
FUNCTION
X X
Yellow LED
Green LED
Green LED
Green LED
Green LED
Green LED
ON/OFF
Two-position
switch
RST
Pushbutton
ACCESS (1-8)
ACCESS (9-16)
Female
37-pin sub-D
connector
Link with access units EXT. (1/8) and EXT. (9/16) connectors.
X X X
DC 24V-48V *
Male
3-pin sub-D
connector
X X X
ESC. MAIN
Female
37-pin sub-D
connector
Link with the main IDUs ESC EXT connector for ESC
extension.
X X X
X X
X
48/374
3CC14295AGAA TQ BJA 01
A B C
ITEM
TYPE
X X X
MAIN
Female
68-pin mini-D
connector
X X X
ESC. 5
Female
25-pin sub-D
connector
Female
50-pin mini-D
connector
Not used.
X X X BACK TO BACK
FUNCTION
X X X
ESC. 4-1 *
ESC. 4-2 *
Female
9-pin sub-D
connectors
X X X
ESC. 3-1 *
ESC. 3-2 *
Female
9-pin sub-D
connector
ODU
Female
N connector
C-NMS1
C-NMS2
Female
9-pin and 15-pin
sub-D connectors
X X
Options
Not used.
3CC14295AGAA TQ BJA 01
49/374
The connector panel of the access indoor unit is fitted with the components described in the table below:
ITEM
TYPE
I/O (1/8)*
I/O (9/16)*
Female
37-pin sub-D
connector
MAIN (1/8)
MAIN (9/16)
EXT. (1/8)
EXT. (9/16)
FUNCTION
2 Mbit/s access version (use of IDU type 1, see 7.2.2.2):
Tributaries 1 to 16.
34 Mbit/s access version:
2 Mbit/s auxiliary bit stream port.
34 Mbit/s ports on 1.6/5.6 coaxial sockets on a panel mounted in
place of the top I/O (9/16) connector.
Female
37-pin sub-D
connectors
Female
37-pin sub-D
connectors
50/374
3CC14295AGAA TQ BJA 01
2.8
--
Technical characteristics
9413 UX
EN 301 128
266
9413 UX
16QAM
EN 301 128
266
9415 UX
EN 301 128
15 GHz
14.4--15.35
ERC 12--07
ITU--R Rec F636--3
728,
315, 420, 490
EN 301 128
18 GHz
17.7--19.7
ERC 12--03
ITU--R Rec F595--3
1008, 1010,
340, 1560, 1092.5
EN 300 198
23 GHz
21.2--23.6
1008, 1197,
1200, 1232
EN 300 198
23 GHz
21.2--23.6
1008, 1197,
1200, 1232
EN 300 431
25 GHz
24.5--26.5
1008
9425 UX
16QAM
EN 300 431
25 GHz
24.5--26.5
1008
9438 UX
EN 300 197
38 GHz
37--39.5
ERC 12--01
ITU--R Rec F749--1
1260
EN 300 197
38 GHz
37--39.5
ERC 12--01
ITU--R Rec F749--1
1260
4QAM
Band
(GHz)
Frequency
(GHz)
Standard *
Tx/Rx
separation (MHz)
Equipment
4QAM/16QAM
9418 UX
4QAM/16QAM
9423 UX
4QAM
9423 UX
16QAM
9425 UX
4QAM
4QAM
9438 UX
16QAM
Channeling
RF CHANNELING
Capacity (Mbit/s)
2x2
4x2
8x2
16x2 / 34 + 2
RF Channeling (MHz)
3.5
14
28
--
--
14
(4QAM modulation)
RF Channeling (MHz)
(16QAM modulation)
3CC14295AGAA TQ BJA 01
51/374
Equipment
Max frequency
agility band
depending on
duplex
difference
(MHz)
Output Power
(dBm)
9413 UX
116
25
Fixed attenuator: 3, 6, or
10 dB for 3CC08879AAxx
116
25
116
21
220
21
Fixed attenuator: 3, 6, or
10 dB for 3CC08880AAxx
220
24
480
16
Fixed attenuator: 3, 6, or
10 dB
4QAM
9413 UX
4QAM RTPC
9413 UX
16QAM
9415 UX
4QAM
9415 UX
4QAM RTPC
9418 UX
24*
4QAM
500
19
9423 UX
16QAM
500
17
9425 UX
450
18
9425 UX
16QAM
450
16
9438 UX
560
16
560
14
9423 UX
4QAM RTPC
4QAM RTPC
4QAM RTPC
9438 UX
16QAM
(*) Consult Alcatel for availability of this option.
52/374
3CC14295AGAA TQ BJA 01
Equipment
Frequency
agility band
(MHz)
4 QAM
9413 UX
266
16 QAM
116
4 QAM
9415 UX
16 QAM
4 QAM
9418 UX
340,
1008 1010
1008,1010,
1560, 1092.5
16 QAM
4 QAM
9423 UX
220
480
1008, 1200,
500
1232
16 QAM
4 QAM
9425 UX
1008
16 QAM
450
4 QAM
9438 UX
1260
16 QAM
560
Output power
setting (dB)
(RTPC)
ATPC range
24 to 4 dBm
+20 to 10 dBm
with 1 dB step
20 to 0 dBm
24 to 4 dBm
+20 to 10 dBm
with 1 dB step
20 to 0 dBm
22 to 2 dBm
19 to --1 dBm
19 to --1 dBm
+16 to 14 dBm
with 1 dB step
16 to --4 dBm
+17 to 13 dBm
with 1 dB step
17 to --3 dBm
+14 to 16 dBm
with 1 dB step
14 to --6 dBm
+16 to 14 dBm
with 1 dB step
16 to --4 dBm
+13 to 17 dBm
with 1 dB step
13 to --7 dBm
2x2
4x2
8x2
16x2 / 34 + 2
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
9413 UX 4QAM
--95
--92
--92
--89
--89
--86
--86
--83
9413 UX 16QAM
--
--
--
--
--83
--80
--80
--77
9415 UX 4QAM
--94
--91
--91
--88
--88
--85
--85
--82
9418 UX 4QAM
--94
--91
--91
--88
--88
--85
--85
--82
9423 UX 4QAM
--92
--89
--89
--86
--86
--83
--83
--80
9423 UX 16QAM
--
--
--
--
--82
--79
--79
--76
9425 UX 4QAM
--91
--88
--88
--85
--85
--82
--82
--79
9425 UX 16QAM
--
--
--
--
--81
--78
--78
--75
3CC14295AGAA TQ BJA 01
53/374
Equipment
2x2
4x2
8x2
16x2 / 34 + 2
9438 UX 4QAM
--87
--84
--84
--81
--81
--78
--78
--75
9438 UX 16QAM
--
--
--
--
--77
--74
--74
--71
BER THRESHOLDS AT ANTENNA PORT FOR NEW GENERATION A9400UX flat ODU
Equipment
9413 UX
9415 UX
9418 UX
9423 UX
9425 UX
9438 UX
2x2
4x2
8x2
16x2 / 34 + 2
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
4 QAM
--95
--92
--92
--89
--89
--86
--86
--83
16 QAM
--
--
--
--
--84
--81
--81
--78
4 QAM
--95
--92
--92
--89
--89
--86
--86
--83
16 QAM
--
--
--
--
--84
--81
--81
--78
4 QAM
--93
--90
--90
--87
--87
--84
--84
--81
16 QAM
--
--
--
--
--82
--79
--79
--76
4 QAM
--93
--90
--90
--87
--87
--84
--84
--81
16 QAM
--
--
--
--
--82
--79
--79
--76
4 QAM
--92
--89
--89
--86
--86
--83
--83
--80
16 QAM
--
--
--
--
--81
--78
--78
--75
4 QAM
--91
--88
--88
--85
--85
--82
--82
--79
16 QAM
--
--
--
--
--79
--76
--77
--74
CONFIGURATION
Additional branching losses per terminal *
Tx
Rx
1+0 or1+1 FD
S Main Channel
S Stand--By channel
11
11
1+0/1+1 FD SYSTEM GAIN AT ANTENNA PORT (INCLUDING DUPLEXER LOSS) FOR ODU
94XXUXR201, 94XXUXR202 OR 94XXUXR203
Equipment
2x2
4x2
8x2
16x2 / 34 + 2
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
9413 UX 4QAM
120
117
117
114
114
111
111
108
9413 UX 16QAM
--
--
--
--
104
101
101
98
9415 UX 4QAM
115
112
112
109
109
106
106
103
54/374
3CC14295AGAA TQ BJA 01
Equipment
2x2
4x2
8x2
16x2 / 34 + 2
9415 UX 4 QAM
RTPC
118
115
115
112
112
109
109
106
9418 UX 4QAM
111
108
108
105
105
102
102
99
9423 UX 4QAM
111
108
108
105
105
102
102
99
1+0/1+1 FD SYSTEM GAIN AT ANTENNA PORT (INCLUDING DUPLEXER LOSS) FOR ODU
94XXUXR201, 94XXUXR202 OR 94XXUXR203
Equipment
2x2
4x2
8x2
16x2 / 34 + 2
9423 UX 16QAM
--
--
--
--
99
96
96
93
9425 UX 4QAM
109
106
106
103
103
100
100
97
9425 UX 16QAM
--
--
--
--
97
94
94
91
9438 UX 4QAM
103
100
100
97
97
94
94
91
9438 UX 16QAM
--
--
--
--
91
88
88
85
1+0/1+1 System gain At antenna port (including duplexer loss) for A9400UX flat ODU
Equipment
9413 UX
9415 UX
9418 UX
9423 UX
9425 UX
9438 UX
4 QAM
2x2
4x2
8x2
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
10 - 3
10 - 6
119
116
116
113
113
110
110
107
104
101
101
98
113
110
110
107
104
101
101
98
109
106
106
103
101
98
98
95
106
103
103
100
98
95
95
92
103
100
100
97
95
92
92
89
101
98
98
95
92
89
90
87
16 QAM
4 QAM
119
116
116
113
16 QAM
4 QAM
115
112
112
109
16 QAM
4 QAM
112
109
109
106
16 QAM
4 QAM
109
106
106
103
16 QAM
4 QAM
16x2 / 34 +2
107
104
104
101
16 QAM
Non--integrated
60 cm
Flextwist loss
*
>35
60 cm
90 cm
120 cm
180 cm
0.35
>38.3
>41
>44.6
15 GHz
>30.5
>36
0.5
>39.5
>42
>45.5
18 GHz
>32.7
>38
0.7
>41.6
>44
>47.3
3CC14295AGAA TQ BJA 01
55/374
Integrated
Non--integrated
23 GHz
>34.4
>39.6
0.7
>43.1
>45.6
25 GHz
>35.6
>40.7
0.7
>44.2
>46.8
38 GHz
>39.3
>44.2
>48.9
250 kHz
RF stability
+/-- 10 ppm
Spectrum masks
Spurious
emissions
Equalizer Type
Link Identity
Code
32 codes
TRIBUTARY INTERFACES*
2 Mbit/s ITU--T G.703 120 ohms or 75 Ohms
Type
Jitter
Man--Machine Interface
Visual
7 LEDs
other
Equipment alarms
2 outputs
Environmental
events
8 inputs / 1output
* In the case of a 75 Ohms connection, the respect of the G703 norms and EMC norms is only guaranteed by
ALCATEL if spider adapters made for this purpose are used (3CC07885Axxx or 3CC07759Axxx) with the IDU
configuration.
POWER SUPPLY
DC
nominal
(primary)
24 VDC
48 VDC
Polarity
56/374
3CC14295AGAA TQ BJA 01
POWER SUPPLY
Max Power
consumption for
ODU 94XXUXR201,
94XXUXR202 OR
94XXUXR203
Max Power
1 + 0 : 60 W
consumption for
A9400UX flat ODU
1 + 1 : 112 W
1+1 : 120W
Safety
EN 60 950
Power supply
EN 300 132
Lightning protection
IDU--ODU CABLE
Type
1AC001100022
Fire resistance
IEC 332--1
Max length
300 m
ENVIRONMENTAL CONDITIONS
Storage
Transport
IDU
Operation
ODU
3CC14295AGAA TQ BJA 01
57/374
MECHANICAL
Classic Main IDU,
Extension IDU, Access IDU
Light IDU
ODU
94XXUXR201
94XXUXR202
94XXUXR203
ODU
A9400UX flat
13 to 18
GHz
250x250x250 mm / 10kg
23 to 38
GHz
220x220x250 mm / 8 kg
13 to 38
GHz
235x235x72 mm / 4 kg
58/374
3CC14295AGAA TQ BJA 01
2.9
--
Equipment
9413 UX
9415 UX
Duplex spacing
(MHz)
266
315
420
490
644
728
3CC14295AGAA TQ BJA 01
Tx Band (MHz)
F min
F max
12751.75
12864.25
12861.75
12978.25
1P
13017.75
13130.25
2P
13127.75
13244.25
14635.75
14765.25
14761.75
14898.25
1P
14950.75
15080.25
2P
15076.75
15213.25
14502.75
14723.50
14719.75
14940.25
1P
14922.75
15143.25
2P
15139.75
15360.25
14404.75
14632.25
14628.75
14856.25
1P
14894.75
15122.25
2P
15118.75
15346.25
14500
14700
1P
15144
15344
14502.75
14618.25
1P
15230.75
15346.25
59/374
Equipment
9418 UX
Duplex spacing
(MHz)
340
1560
1010
1008
1092.5
60/374
Tx Band (MHz)
F min
F max
18581.75
18698.25
18701.75
18818.25
1P
18921.75
19038.25
2P
19041.75
19158.25
17701.75
18138.25
1P
19261.75
19698.25
17701.75
18199.25
18180.75
18688.25
1P
18711.75
19210.25
2P
19190.75
19698.25
17703.75
18199.25
18182.75
18678.25
1P
18711.75
19207.25
2P
19190.75
19686.25
17702
18090
18205
18597.5
1P
18794.5
19182.5
2P
19297.5
19690
3CC14295AGAA TQ BJA 01
Equipment
9423 UX
Duplex spacing
(MHz)
1008
(9423UX R201,
R201
9423UX R202)
1008
(9400UX flat
ODU)
1232
1200
9425 UX
9438 UX
1008
1260
3CC14295AGAA TQ BJA 01
Tx Band (MHz)
F min
F max
22001.75
22490.25
22101.75
22590.25
1P
23009.75
23498.25
2P
23109.75
23598.25
22001.75
22302,00
22300.00
22600.00
1P
23008.00
23310,00
2P
23308.00
23598.25
21201.75
21786.25
21781.75
22366.25
1P
22433.75
23018.25
2P
23013.75
23598.25
21201.75
21818.25
21781.75
22398.25
1P
22401.75
23018.25
2P
22981.75
23598.25
24549.75
24996.25
24997.75
25444.25
1P
25557.75
26004.25
2P
26005.75
26452.25
37059.75
37616.25
37619.75
38176.25
1P
38319.75
38876.25
2P
38879.75
39436.25
61/374
62/374
3CC14295AGAA TQ BJA 01
3 -- Installation
--
3.1
Delivery
one or more packages containing the antennas, HSB coupler and installation accessories, service
telephone, cables, etc.
Nr. of
boxes
1+0
1 or 2
Classic IDU
CONFIG.
Nr. of
boxes
1+0
1 or 2
1+1
1 or 2
1+1 with
MUX
protection
1 or 2
CONTENT
1 Light IDU (19 ) + 1 ODU + 1 connector kit + documentation
CONTENT
1 main IDU + 1 ODU + 1 software feature key + 1 connector kit + documentation
+ eventually 1 extension IDU.
1 main IDU + 1 ODU + 1 software feature key + 1 connector kit + documentation.
1 extension IDU + 1 ODU + 1 connector kit.
1 main IDU and if necessary 1 access IDU + 1 ODU + 1 software feature key + 1
connector kit + documentation.
1 extension IDU + 1 ODU + 1 connector kit.
3.1.1.2 -- Unpacking
--
--
Take an inventory and identity any missing items. If the delivery does not match the delivery advice
note, notify ALCATEL within 48 hours of receipt of the equipment.
--
3.1.1.3 -- Storage
If installation is to be deferred, the type of packaging will define the equipment storage conditions:
-- cardboard boxes should be warehoused indoors, in a dry, well aired room.
--
wooden or plywood boxes may be stored outdoors, provided that they are protected from rain and the
suns rays.
3CC14295AGAA TQ BJA 01
63/374
3.2
--
The labels below are also affixed to the boxes to indicate their contents.
TYPICAL LABEL ON THE LIGHT IDU
20 to 40 V=
39 to 60 V =
4x2 Mbit/s
YES
YES
YES
V.11 or V.28
DD / MM / YYYY
Edition date
Memory extension
Slave
UX basic software
9400UXN001
Light UX software
9400UXN002
20 to 40 V =
39 to 60 V =
Memory extension
Cable interface
type
Service channel 3
port type
IDU
address
for
supervision bus
Audio service channel
phone number
Commercial code
: see list in Appendix 9
64/374
3CC14295AGAA TQ BJA 01
20 to 40 V =
39 to 60 V =
Maximum IDU
capacity (according to
equipment)
75, 120 ohms, high impedance
(mux protection) or automatic
interface
300-3400 Hz 4 wire
commercial code
SC4
port
type
corresponding
commercial code
V.11
V.28
Commercial code
75 ohms
120 ohms
* IDU model
* Serial number
Commercial code
* bar coded or in plain language
3CC14295AGAA TQ BJA 01
65/374
Std = Standard
High= High power
RF local loopback
Duplex difference
for transmission
* Serial number
* bar coded or in plain language
P/N
}
}
Commercial code
Min and max operation frequencies for transmission
Duplex difference
Edition date
*Industrial code / revision index
* Serial number
* bar coded or in plain language
10dB
Coupling value
10 dB
Operating frequency
band
* Unit mode
* Serial number
Commercial code
* bar coded or in plain language
66/374
3CC14295AGAA TQ BJA 01
ALCATEL 9400 UX
U
Master or Slave
Y (yes) + commercial
code or N (no)
1+0 max. or
1+1 max
2 x2 ; 4 x2 ; 8 x2 ;
16 x 2 ; 34 Mbit/s
module
7
40 GHz
Y (yes) + commercial
code or N (no)
Transmit frequency
range
* Model of key /
Revision index
* Serial number of key
Commercial code
* bar coded or in plain language
Not meaningful
Configuration :
1 + 0 MAX
or 1 + 1 MAX
Not meaningful
N
N
7125.00 -- 8500.00
3CC07619AAAA 01
C98085113 (05)
3CC14295AGAA TQ BJA 01
67/374
38
38
13
244
365
469
545
68/374
3CC14295AGAA TQ BJA 01
522
556
160
174
625
365
3CC14295AGAA TQ BJA 01
318
389
244
545
69/374
3.3
--
It is assumed that the installer has already installed the other peripheral equipment (cable trays, multiplexes,
etc).
Tool
2.5 mm Allen key (for M3 screw)
x For adjusting the polarization of the antenna and the HSB coupler
x For adjusting the polarization of the antenna and the HSB coupler
For fixing the pole mounting and various fastening with the correct
torque
5 mm flat wrench
10 x 100 mm screwdriver
(for slotted head screws)
The above tools marked with an x are included in a station toolkit, ref: 9400UXT103.
Depending on installation, additional equipment may be useful:
-- Mars Actel OSA3 Compax insertion and extraction tool, for wiring compax terminal blocks (mars actel
IDC) COMPAX; and Sub-D plug crimping tool, ref: 608868-1 (AMP).
Of course, normal installers tools are essential: drill, drill bits, soldering iron, cable tie pliers, terminal pliers, etc.
70/374
3CC14295AGAA TQ BJA 01
Screw caliber
Ncm
Screw M3
61
Screw M4
150
Screw M6
490
Screw M8
1190
Screw M10
2380
200
--
3.4
Installing 19 IDUs
in a laborack or 9U subrack.
Main IDU
Access IDU
Extension IDU
Main IDU
Extension IDU
Before installation, check the labels for IDU configuration information (bit rates and port impedances), type of
remote indication loops, EOW configuration.
CAUTION: do not place anything on the indoor units
3CC14295AGAA TQ BJA 01
71/374
70
kit : 9400UXI301
P = 360
H = 451,15
Useful cable
way 27x210
1+1 mux protected configuration : each group of 2 or 3 IDU shall be separated by 1U.
--
This configuration supposes that room temperature should not exceed +45C (and that the temperature at the
IDU level never exceeds 55C) .
These recommendations allow good installation conditions (place for cable interconnections) and good
operation conditions (cooling of the IDU).
72/374
3CC14295AGAA TQ BJA 01
1U
1+1 Mux protected
9 U rack
1U
1U
1U
9 U rack
1U
Ref. : 9400XXI300
85
370
85
UX 1U UNIT
S As standard, the laborack will be secured to the floor by four M6 socket cap
screws supplied with the equipment.
430
When you have correctly positioned the fixing brackets on the 19 unit, the equipment will be
held by the front panel by four screws fitted into the laboracks cage nuts.
3CC14295AGAA TQ BJA 01
73/374
74/374
3CC14295AGAA TQ BJA 01
--
3.5
There are also supports for fixing the pole to the wall: please consult us.
Various antenna types and sizes can be used, together with radio systems operating at different frequencies
and in a variety of configurations.
CAUTION:
Take care not to damage the O--Ring on the nose of the antenna connection.
If the ODU is not to be mounted immediately after the pole mounting of the antenna,
protect the connection nose (from water, dirt and impact).
For installation with non--integrated antenna, please refer to the antenna manufacturer recommendations.
3CC14295AGAA TQ BJA 01
75/374
3.5.1.2 -- ODU
9400 UX Outdoor units are designed for assembly:
-- either with an integrated antenna connected directly to the Outdoor equipment, see 3.5.4.1 and 3.5.5,
--
or with one or more non--integrated antennas, see 3.5.6., mounted with flextwist guides.
221 (257)
231 (231)
221 (257)
Coaxial to IDU
273 (273)
189 (189)
Ground socket
42
(42)
47
(47)
235
248
248,5
235
115,8
Coaxial to IDU
Ground socket
76/374
3CC14295AGAA TQ BJA 01
TOP
Vertical polarization
Horizontal polarization
O-ring seal
TOP marker
Socket cap screw
Drain orifice
To change the polarization: undo the three socket cap screws and turn the nose through 90 degrees then
tighten the screws again.
CAUTION: The O--ring must be coated with silicone grease before fitting (the grease is
provided with the antenna).
Azimuth: 10 degrees.
To avoid obstacles (wall too close, etc), you can fix the pole mounting on any side of the pipe. The dimensions
of the outdoor equipment are given in 3.2.1.
NOTE: The pole mounting 9400UXI102 is not designed to be fixed directly to the wall
Procedure :
-- 1) Position the antenna vertically (nose horizontal), with the drain hole in the bottom part and free of
obstacles.
3CC14295AGAA TQ BJA 01
77/374
--
2) Insert the 7 M6 screws 1 with their onduflex springy crinkle washers 2 , tighten and secure the
screws (these screws can be found in a plastic bag located inside the casting.
Top marker
Flat washer
Grower washer
Nut
Centering pin
or screw
M6 x 7 screws and
Ondulex washer x 7
Casting
Optional kit:
9400UXI103
OR
ODU 94XXUXR201,94XXUXR202,
94XXUXR203
78/374
3CC14295AGAA TQ BJA 01
Remove the solar shield by undoing the M6 fixing screw with a 16 mm flat wrench.
--
Take the ODU by the handle, offer up the two protrusion bosses inside the nose of the unit to the two
grooves in the nose of the antenna (the ODU-IDU connecting cable entry should be located in the
bottom part of the ODU). Still holding the ODU, engage without fastening the top catch on the support,
begin by fastening the two side catches on the support, then fasten the bottom catch, and finish with
the top catch.
Catch bead
Support plate A
Position of catch for F > 20
GHz
for
ODU
from
94xxUXR201 to 94xxUXR203
--
Reposition the solar shield via the back of the ODU from 94xxUXR201 to 94xxUXR203, centre the
bottom ribs of the solar shield in the grooves of the ODU. Slide fully home, and moderately tighten
by hand the screw (M6) in the recess on the underside of the ODU. Check the assembly by trying to
extract the solar shield from its recess.
Note: The locking screw is not a fixing, it is simply intended to safeguard against inadvertent dismantling; do
not overtighten.
CAUTION: If the screw cannot be reached by hand, use a 16 mm flat wrench (as an
indication, fasten to a torque of 1mN, that is 0.1mdaN).
REMINDER:
The ODU/antenna assembly requires no additional seal on the flanges; the two ends are
smooth. Sealing is provided by the O--ring seal around the male noses.
When the ODU is fitted, the polarization of the antenna can be ascertained from the position of the
ODU handle:
handle arranged vertically = horizontal polarization, and vice versa.
3CC14295AGAA TQ BJA 01
79/374
OR
Vertical polarization
OR
Horizontal polarization
80/374
3CC14295AGAA TQ BJA 01
Remove the solar shield by undoing the M6 fixing screw with a 16 mm flat wrench.
--
Take the ODU by the handle, offer up the two protrusion bosses inside the nose of the unit to the two
grooves in the nose of the antenna (the ODU-IDU connecting cable entry should be located in the
bottom part of the ODU). Still holding the ODU, engage without fastening the top catch on the support,
begin by fastening the two side catches on the support, then fasten the bottom catch, and finish with
the top catch.
Catch bead
Position of catch for
A9400UX flat ODU
Flat ODU
--
--
Reposition the solar shield via the back of the flat ODU. Slide fully home, and moderately tighten by
hand the screw (M4) on the ODU.
CAUTION : When demounting, if the screws cannot be reached by hand, use a screwdriver.
The ODU/antenna assembly requires no additional seal on the flanges; the two ends are
smooth. Sealing is provided by the O--ring seal around the male noses.
When the ODU is mounted, the 50 coaxial jack is always facing down, the natural reading of the
POL H or POL V etching shows the antenna polarization (see Figure 27).
Figure 27 -
3CC14295AGAA TQ BJA 01
81/374
In vertical or horizontal polarization, the solar shield remains fixed in the same position and the
ODU is the only part which can rotate 90 degrees when changing the polarization. (See Figure 28).
Solar shield
Horizontal polarization
82/374
Azimutal coarse pointing has to be carried out when installing the pole mounting.
3CC14295AGAA TQ BJA 01
OR
ODU 94XXUXR201,94XXUXR202,
94XXUXR203
Elevation alignment is performed only with the elevation turnbuckles. If the elevation angle is
higher that (+ 5) or lower than (-- 5), it is necessary to:
--
remove completely one of the 2 screws fixing the antenna support on the azimutal support and,
--
3CC14295AGAA TQ BJA 01
83/374
si --5_<<5_
= 25 _
= 25 _
si:
ou
or
>5 _
<- 5_
84/374
3CC14295AGAA TQ BJA 01
elevation: 25 degrees.
elevation: 9 degrees.
If you have physical difficulties assembling the mounting (wall too close, obstacle, etc), the azimutal turnbuckle
can be moved and mounted on the other side of the pole mounting arm.
Procedure :
-- 1) Position the antenna vertically (nose horizontal), with the drain hole in the bottom part and free of
obstacles.
--
2) Insert the 7 M6 screws 1 with their onduflex springy crinkle washers 2 , tighten and secure the
screws (these screws can be found in a plastic bag located inside the casting).
3CC14295AGAA TQ BJA 01
85/374
Top marker
Centering pin
or screw
7 x M6 screw and
Onduflex washer
1 2
or
ODU
94XXUXR201,
94XXUXR202,
94XXUXR203
Casting
Nut
Grower washer
flat washer
Optional kit
9400UXI103
CAUTION: The O--ring must be coated with silicone grease before fitting.
86/374
3CC14295AGAA TQ BJA 01
Take the ODU by the handle, offer up the two protrusion bosses located inside the nose of the unit
and facing the two grooves in the nose of the antenna (the ODU-IDU connecting cable entry should
be located in the bottom part of the ODU). Still holding the ODU, engage without fastening the top
catch on the support, begin by fastening the two side catches on the support, then fasten the bottom
catch, to complete with the top catch.
Catch bead
Support plate A
Position of catch for F > 20
GHz
for
ODU
from
94xxUXR201 to 94xxUXR203
--
Swivel the antenna support through 90 on its azimuthal axis to release it from the pole. Immobilize
the vertical axis by the five screws (see Figure 32, item 3 ).
--
Reposition the solar shield via the back of the ODU, centre the bottom ribs of the solar shield in the
grooves of the ODU. Slide fully home, and moderately tighten by hand the screw (M6) in the recess
on the underside of the ODU. Check the assembly by trying to extract the solar shield from its recess.
Note: The locking screw is not a fixing, it is simply intended to safeguard against inadvertent dismantling; do
not overtighten.
CAUTION: If the screw cannot be reached by hand, use a 16 mm flat wrench (as an
indication, fasten to a torque of 1mN, that is 0.1mdaN).
REMINDER:
The ODU/antenna assembly requires no additional seal on the flanges; the two ends are
smooth. Sealing is provided by the O--ring seal around the male noses.
For a 1+0 configuration, when the ODU is fitted, the polarization of the antenna can be ascertained
from the position of the ODU handle:
handle arranged vertically = horizontal polarization, and vice versa.
Take the ODU by the handle, offer up the two bosses located inside the nose of the unit and facing
the two grooves in the nose of the antenna (the ODU-IDU connecting cable entry should be located
in the bottom part of the ODU). Still holding the ODU, engage without fastening the top catch on the
support, begin by fastening the two side catches on the support, then fasten the bottom catch, to
complete with the top catch.
Catch bead
Position of catch for
A9400UX flat ODU
--
Flat ODU
Swivel the antenna support through 90 on its azimutal axis to release it from the pole. Immobilize the
vertical axis by the five screws (see Figure 32, item 3 ).
3CC14295AGAA TQ BJA 01
87/374
--
--
Reposition the solar shield via the back of the flat ODU. Slide fully home, and moderately tighten by
hand the screw (M4) on the ODU.
CAUTION : When unscrewing, if the screws cannot be reached by hand, use a screwdriver.
The ODU/antenna assembly requires no additional seal on the flanges; the two ends are
smooth. Sealing is provided by the O--ring seal around the male noses.
When the ODU is mounted, the 50--ohm coaxial jack is always facing down, the natural reading
of the POL H or POL V etching shows the antenna polarization (see Figure 27).
1) Roughly adjust the elevation orientation of the pole mounting in the direction of the remote
station. The elevation turnbuckle should remain in its middle position. Use the antenna top marker (see
figures in 3.5.2), a compass and binoculars, then secure the brackets 2 in optional Kit 9400UXI103.
CAUTION: The bracket nuts should be fastened to a torque of 3 m.daN +/-- 20%.
The brackets must be clean and without grease except on the threads.
--
2) Roughly point the antenna support towards the required azimuthal by undoing the azimuthal
locking screw. The azimuthal turnbuckle should remain in its middle position (approximately 85 mm
centres); swivel the antenna support vertically for adjustment purposes, then retighten the azimuthal
locking screw.
CAUTION: The azimuthal turnbuckle should not exceed 94 mm centre distance when
fine tuning the adjustment.
CAUTION:
Never mount integrated antennas and ODUs under the pole mounting support.
Never mount the elevation axis horizontally:
ODUs must be above the pole mounting and not laterally offset.
--
88/374
3) On the pole mounting, undo the 4 + 1 M8 screws (item 3 - see figure below) so that you will be
able to fit the ODU later.
3CC14295AGAA TQ BJA 01
Pole mounting
3
Azimuthal locking
screw
Kit 9400UXI103
(optional)
2
Figure 32 - Pointing the antenna
--
4) Position the U bolts 2 on the pole, fit the flat washers, grower washers and nuts.
CAUTION: For the fasten torques of the screws, refer to chapter 3.3.4.
3CC14295AGAA TQ BJA 01
89/374
Antenna
Solar shield
Main ODU
Coupler
Standby ODU
Solar shield
Main ODU
Antenna
Coupler
Standby ODU
90/374
3CC14295AGAA TQ BJA 01
Do not remove the sealing window located on the antenna port. The ODU/coupler/antenna
assembly requires no additional seal on the flanges; the flanges are smooth and sealing is provided
by the O--ring seal located around the male noses.
--
fix the coupler using three M6 x 35 mm screws and nuts in the holes in the top lugs of the pole
mounting.
--
secure the coupler by the two side screws (M6 x 30) on the pole mounting.
Fixing holes on radio support ring of pole
mounting
O-ring seal
CAUTION: The seal should be
coated with silicon grease before
assembly
Standby ODU
Antenna
port
CAUTION: The O--ring must be coated with silicon grease before assembly (the grease
is provided with the HSB).
INSTALLING ODU
The positions of the main and standby ODUs are shown in the previous figures; for installing the ODUs, see
3.5.4.1.
3.5.5.2 -- Typical 1+1 HSB CONFIGURATION WITH THE NEW HSB COUPLER
This type of coupler must only be used with the A9400UX flat ODUs.
3CC14295AGAA TQ BJA 01
91/374
1) U bolts
2) Pole mounting
3) Radio mounting
4) Fastening points for COUPLER
5) Screws fastening the antenna to the support
6) Antenna screw--fastening slots
7) RF Coupler Fastening brackets for ODU
8) Grounding points
INSTALLING THE HSB COUPLER
For the frequencies above 20 GHz, the ODU is fitted with a nose adapter to remain mechanically compatible
with the HSB coupler 94xxUXR111. Unscrew the 2 Torx screws to remove the adapters on both ODUs. Fix one
of the two adapters to the antenna access of the HSB coupler. Fasten the coupler to the support through the
four locking hooks (1) that will be tightened onto the relative fastening brackets on the radio support (2).
92/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
93/374
Install the antenna on the pipe, according to the instructions given by the manufacturer and supplied
with the antenna, and prepoint the antenna towards the remote station using a compass and a pair of
binoculars,
--
--
Install the HSB coupler on the pole mounting (only for 1+1 configuration), see 3.5.5,
--
--
Install the flextwist (suited to the frequency) between the pole mounting and the antenna, see 3.5.6.6.
94/374
3CC14295AGAA TQ BJA 01
Flextwist
Square flange
with groove
ODU 94xxUXR201 or
94xxUXR202 or 94xxUXR203
Adpater nose
Support radio
94XXUXI102
Flextwist
ODU 9400UX flat ODU
Support radio
94XXUXI102
3CC14295AGAA TQ BJA 01
95/374
a microwave nose,
--
Flextwist flanges
Radio side
flange
Flextwist
reference
13 GHz
PBR 120
UBR 120
9413UXI103
15 GHz
PBR 140
UBR 140
9415UXI103
PBR 220
UBR 220
94XXUXI103
18 GHz
23/25 GHz
38 GHz
Horizontal
polarization
--
Choose the horizontal or vertical polarization to match that of the ODU before fixing nose C (type
dependent on the frequency) on plate A with the three M4 x 16 socket cap screws (3 mm Allen key).
--
Choose the direction of assembly of plate B (on the right or on the left of the pipe); this should match
that of the antenna, then bolt the plate A onto plate B with four M10 x 35 hex nuts and four washers.
--
Offer up the assembly to the antenna support pipe, then secure it with the M10 U bolts, nuts, lock nuts
and washers.
--
Check that all the screw fastenings are correctly tightened. For the fasten torques of the screws, refer
to 3.3.4.
CAUTION: The O--ring must be coated with silicone grease before fitting (the grease is
provided with the microwave nose).
96/374
3CC14295AGAA TQ BJA 01
1) Remove the solar shield by undoing the M6 fixing screw with a 16 mm flat wrench.
--
2) Take the ODU by the handle, offer up the two bosses inside the nose of the unit to the two grooves
in the adapter nose (the ODU-IDU connecting cable entry should be located in the bottom part of the
ODU). Still holding the ODU, engage without fastening the top catch on the support, begin by fastening
the two side catches on the support, then fasten the bottom catch and finish with the top catch.
Catch bead
Support plate A
Position of catch for F > 20
GHz
for
ODU
from
94xxUXR201 to 94xxUXR203
--
3) Reposition the solar shield via the back of the ODU, centre the bottom ribs of the solar shield
in the grooves of the ODU. Slide fully home and, by hand, tighten the screw (M6) in the recess on
the underside of the ODU. Check the assembly by trying to extract the solar shield from its recess
Remove the solar shield by undoing the M6 fixing screw with a 16 mm flat wrench.
--
Take the ODU by the handle, offer up the two bosses located inside the nose of the unit and facing
the two grooves in the nose of the antenna (the ODU-IDU connecting cable entry should be located
in the bottom part of the ODU). Still holding the ODU, engage without fastening the top catch on the
support, begin by fastening the two side catches on the support, then fasten the bottom catch, to
complete with the top catch.
Catch bead
Position of catch for
A9400UX flat ODU
Flat ODU
--
--
Reposition the solar shield via the back of the flat ODU. Slide fully home, and moderately tighten by
hand the screw (M4) on the ODU.
CAUTION : When unscrewing, if the screws cannot be reached by hand, use a screwdriver.
The ODU/antenna assembly requires no additional seal on the flanges; the two ends are
smooth. Sealing is provided by the O--ring seal around the male noses.
The ODU/antenna assembly requires no additional seal on the flanges; the two ends are
smooth. Sealing is provided by the O--ring seal around the male noses.
When the ODU is mounted, the 50--ohm coaxial jack is always facing down, the natural reading
of the POL H or POL V etching shows the antenna polarization (see Figure 27).
3CC14295AGAA TQ BJA 01
97/374
--
six M4 x 20 or M3 x 16 stainless steel socket cap screws (13/15 GHz or 18/23/25 GHz versions
respectively),
--
six M4 x 12 (13/15 GHz) or M3 x 12 (18/23/25 GHz) stainless steel socket cap screws,
--
--
12 18/10 stainless B4 (13/15 GHz) or B3 (18/23/25 GHz) Onduflex springy crinkle washers ,
--
six 18/10 stainless HM4 (13/15 GHz) or HM3 (18/23/25 GHz) hex nuts,
--
98/374
3CC14295AGAA TQ BJA 01
3.6
--
Wiring
- V female contact
Ground
+V female contact
3CC14295AGAA TQ BJA 01
99/374
For both these products, the fuses used are 8.5 x 31.5 6A 400V gG domestic type cartridges.
The cables supplied to connect the IDUs are:
-- 48 V: 3CC08165AAxx(3 x 1.5 mm2),
--
24 V:
24 V : 3CC08212AAxx (3 x 10 mm2).
--
Earthing is bonded using green/yellow insulated cable with a minimum cross sectional area of 1x16 mm2
towards the grounding vertical run. Wiring should be kept as short as possible. The overall length for all of the
connections must not exceed 20 metres.
In addition, the IDU/ODU cable may be grounded using kit: 9400UXI204
The ground connection for the ODU part should not be done through the lightning
conductor.
3.6.2.1 -- On 19 indoor units (IDU)
The ground terminal comprises a tapped terminal (connector side of the unit, alongside the IDU/ODU coaxial
socket), to which is fastened (by its M6 screw) a crimp terminal.
100/374
3CC14295AGAA TQ BJA 01
tapped hole
for ground
terminal
grounding
kit 9400UXI204
The installation
of the grounding
kit is necessary
only if D > 80 m
D
Indoor
3CC14295AGAA TQ BJA 01
101/374
Lightning finial
bonded to tower
I.F. cable
Boundary fence ground
via building ground ring
Tower and building ground rings interconnected (driven electrode systems shown)
Figure 34 - Typical example of good grounding practice [ETSI document Draft EG 200 053 V1.4.3
(2002- 02) (Page 91/145), informative]
102/374
3CC14295AGAA TQ BJA 01
OR
ODU
The cable is fixed along the supporting pipe or pole by the normal methods (Colson cable ties are supplied in
the optional consumables kit)
3CC14295AGAA TQ BJA 01
103/374
I/O (9/16) on the main IDU for 1+0 and 1+1 configurations,
--
I/O (9/16) on the access IDU for 1+1 configurations with MUX protection.
If a BNC connector is required for the 34 Mbit/s stream, use a BNC/1.6/5.6 adapter kit, ref: 9400XXI405.
1.6/ 5.6 connector
34 Mbit/s port
+ 2 Mbit/s auxilliary
--
In+
In--
Out+
Out--
28
19
37
LAU : 3CC06061AAxx
LIU : 3CC06118AAxx
X
In the 75 version, In+ and Out+ are the live input and output points and In- and Out- are the ground
connectors for the signals.
37-way I/O (1/8) and I/O (9/16) connectors on the main IDU,
37--way I/O (1 -- 4) connectors on the Light IDU version,
37-way I/O (1/8) and I/O (9/16) connectors on the access IDU (1+1 version with MUX protection),
when the access IDU exists.
on 3CC13659AAxx cables (1+1 with MUX protection without access IDU)
In 120 ohms, if the non-distributor option is selected, wire the braces supplied with the IDU-ODU connector
kit (ref: 3CC07899AAxx) using a crimping tool (608868-1, from AMP).
3.6.5.2 -- Wall mounting (9400UXI301) indoor units
S 3U 19 mounting
S The distributors described below can be fixed to a wall using this kit
comprising two brackets + fixing screws (Ref. 3CC07957AAAA).
398 mm
104/374
60 mm
3CC14295AGAA TQ BJA 01
9400XXI404
OUTPUT
TYPE
75
1.6/5.6
CABLE
1 Unit
37-pin
connector
2m
3CC08061AAxx
3CC07885Axxx
1x
9400XXI404
9400XX405
75
BNC
DISTRIBUTOR
37-pin
connector
1 Unit = 44.45 mm
1U
2m
3CC08061ABxx
3CC07759Axxx
For 120 wiring, use the cables provided for the 8 x 2 Mbit/s version.
3.6.5.4 -- 8 x 2 Mbit/s wiring with distributor
COMMERCIAL CODE
OF DISTRIBUTOR
ASSEMBLY
9400XXI408
OUTPUT
TYPE
75
1.6/5.6
CABLE
37-pin
connector
1U
2m
3CC07885Axxx
2x
9400XXI408
9400XXI405
75
BNC
DISTRIBUTOR
37-pin
connector
3CC08061AAxx
1U
2m
3CC08061ABxx
3CC07759Axxx
3U EMC
120
2m
3CC07658Axxx
3CC07810AAxx
9400XXI408
1U
120
2m
3CC07658Axxx
3CC14295AGAA TQ BJA 01
105/374
9400XXI416
OUTPUT
TYPE
75
1.6/5.6
CABLE
37-pin
connector
1U
2m
2 x 3CC07885Axxx
9400XXI416
4 x 9400XXI405
75
BNC
DISTRIBUTOR
37-pin
connector
3CC08061AAxx
1U
2m
3CC08061ABxx
2 x 3CC07759Axxx
3U EMC
120
2m
2 x 3CC07658Axxx
3CC07810AAxx
9400XXI416
1U
120
2m
2 x 3CC07658Axxx
106/374
3CC14295AGAA TQ BJA 01
is used to:
-- supply three signals (outputs) to the equipment (dry loops, 0.5 A/100 V).
--
supply (output) one remote control (dry loop, 0.5 A/100 V).
--
connect eight housekeeping alarm inputs: n1 to n8 alarms. These alarms are formed by normally
opened or normally closed loops, see 7.10.
For the connecting cable, use the connector provided in the connector kits supplied with the IDU--ODU
assembly. The connector pinout is given in the Appendix 6.3.
3CC14295AGAA TQ BJA 01
107/374
3.7
--
( 9 / I6 )
Cable
3CC07160ABxx
Cable
3CC07157ABxx
Main IDU
Extension IDU
Connect the ESC EXT connector on the main IDU to the ESC MAIN connector on the extension IDU using a
cable ref: 9400UXC130 (3CC07157ABxx), with male 37-way connectors (L = 300 mm).
Connect the EXT connector on the main IDU to the MAIN connector on the extension IDU via a cable
ref: 9400UXB221 (3CC07160ABxx), with 68-way rectangular plugs (L = 300 mm).
108/374
3CC14295AGAA TQ BJA 01
NOTE:
When the 1+1 configuration with multiplexer protection is selected, the units must be
arranged physically from top to bottom, as follows: main unit, access unit (when used),
extention unit.
3.7.2.1 -- N x 2 Mbit/s without Access IDU (preferred configuration since the IDU type 2 availability )
MAIN IDU
Cable
3CC07160ABxx
3/16
2 Mbits HDB3
connection
Cable
3CC07157ABxx
Cables
3CC13659AAxx
1/8
Extension IDU
ACCESS (9/16) connector of the extension IDU to the I/O (9/16) connector of the main IDU.
NOTE:
When the 1+1 configuration with multiplexer protection is selected, the units must be
arranged physically from top to bottom, as follows: main unit, extension unit.
3.7.2.2 -- 34 Mbit/s with Access IDU (for both IDU type 1 and IDU type 2)
Main IDU
Cables
3CC07157ABxx
Cable
3CC07160ABxx
Cable
3CC07157ABxx
Access IDU
2 Mbit/s
Extension IDU
34 Mbit/s
EXT (1/8) to the ACCESS I/O (1/8) connector of the extension IDU.
3CC14295AGAA TQ BJA 01
109/374
Cables
3CC07157ABxx
Cable
3CC07160ABxx
Access IDU
Cable
3CC07157ABxx
Extension IDU
Four identical cables (two if the number of tributaries is < 8) ref: 3CC07157ABxx, 37--pin male plugs,
L = 300 mm are used to be connected to the following connectors of the access IDU:
-- MAIN (1/8) to the I/O (1/8) connector of the main IDU.
--
EXT (1/8) to the ACCESS I/O (1/8) connector of the extension IDU.
--
--
EXT (9/16) to the ACCESS I/O (9/16) connector of the extension IDU.
110/374
3CC14295AGAA TQ BJA 01
--
3.8
The wiring in this case is to provide continuity of tributaries and service channels between the various terminals
of the particular station.
and connect the AUDIO1 ports of the second unit to the AUDIO1 ports of the third unit using cable ref:
9400UXC332 (3CC07711AAxx), 2 m long.
3CC14295AGAA TQ BJA 01
111/374
and connect the AUDIO1 ports of terminals (2 and 3), (4 and 5), (6 and 7), etc, via cable
ref: 9400UXC332 (3CC07711AAxx), 2 m long .
Back to back
Audio1 to Audio 1
Back to back
E1
E2
E3
Audio1 to Audio 1
E4
E5
Back to back
E6
9--way connector
3CC07920AAxx
25--way connector
3CC08221AAxx
37--way connector
3CC07899AAxx
LIGHT IDU
Only service channel 3 is available.
-- Prepare specific wiring with 37--way connector 3CC09311AAxx supplied with the connector kit.
112/374
3CC14295AGAA TQ BJA 01
CLASSIC IDU
RST
IDU
LIGHT IDU
This manual applies to the 946LUX50 version of the software installed on the PC.
For the terminal to which it is connected and for the remote terminal (when the link is set up), this software can
be used to:
-- display and administer all alarms, status, remote controls,
--
--
--
--
download software,
--
--
3CC14295AGAA TQ BJA 01
113/374
--
4.1
In addition, for some of the configuration applications, the operator should be aware of certain specifications
of the International Standard Organization (ISO) and of the standards applied to the Plesiochronous Digital
Hierarchy (PDH) (ITU--T Recommandations).
The PC must have the following minimum specifications:
S Pentium III or compatible processor operating at 850 MHz or above,
check that the system date and time are correct and if not, adjust them,
--
114/374
3CC14295AGAA TQ BJA 01
--
4.2
The installation steps for the software in PC WINDOWS--NT/XP/2000 environments (PC disconnected from
Equipment Controller) are as follows:
Installation from software CD--ROM
-- installation of 1320CT + NE software from software CD--ROM
--
CT initial configuration
-- NE login
--
--
CAUTION:
S Procedures described in the following are carried out with the PC disconnected from the NE
The first procedure is used to upgrade the new software in the system, the second one must be used to perform
the first software installation and to upgrade two specific components: Java and LLMan.
The standard installation sequence uses the guided procedure to install the first two components (Java and
LLMan), and then the automatic one to install the other components.
The components that need to be installed are the following:
-- JRE: Java Runtime Environment
--
LLMan: Alcatel Lower Layer Manager (required for craft terminal--to--IDU connection through its
F interface)
--
--
--
--
--
SW Package REG 946LUX50: LUX50 IDU embedded software (for IDU software download)
The following describes (step by step) the procedure to install JRE and Alcatel Lower Layer Manager with
the CT Products guided installation
3CC14295AGAA TQ BJA 01
115/374
Operations sequence:
Step 1. Select CT Products guided installation and press NEXT button.
Step 2. Select JRE and Alcatel Lower Layer Manager components.
116/374
3CC14295AGAA TQ BJA 01
Step 6. Press NEXT button to start the installation of the Lower Layers Manager.
Step 7. Select Configure Lower Layer and press Finish to complete the operation.
3CC14295AGAA TQ BJA 01
117/374
118/374
3CC14295AGAA TQ BJA 01
The following describes the procedure for installing all the components except JRE and Alcatel Lower Layer
Manager with the CT Products automatic installation
Operations sequence:
Step 1. Select the CT Products automatic installation and press Next button.
3CC14295AGAA TQ BJA 01
119/374
Step 2. Select all components except JRE and Alcatel Lower Layer Manager.
120/374
3CC14295AGAA TQ BJA 01
--
Click the Add... button in the Adapter tab of the Network Control Panel applet.
--
In the Select Network Adapter window, click on the Have Disk... button in order to add the Alcatel
Lower Layer network adapter.
3CC14295AGAA TQ BJA 01
121/374
122/374
3CC14295AGAA TQ BJA 01
4.2.2.4 -- Configuring the Alcatel Virtual Network Card for Lower Layers Under Windows NT 4.0
To configure the Alcatel Virtual Network Card for Lower Layers use both the Bindings and the Protocols tabs
in the Network Control Panel applet.
Before configuring Alcatel Virtual Network Card for Lower Layers you need to install TCP/IP protocol (please
refer to Windows NT Help).
To install the Alcatel Virtual Network Card for Lower Layers run the Network Control Panel applet from the
Control Panel.
-- Select the bindings of Alcatel Virtual Network Card for Lower Layers in the Bindings tab (1), (2) of the
Network Control Panel applet.
--
--
Select the Protocols tab (5) of the Network Control Panel applet, then either a message box (NT
configuration step 2) or a dialog box (NT configuration step 3) may appear.
--
Follow the instructions until the dialog box (NT configuration step 4) appears.
2
3
4
3CC14295AGAA TQ BJA 01
123/374
--
Select Protocols tab (1), TCP/IP Protocol (2) and click the Properties button (3).
124/374
3CC14295AGAA TQ BJA 01
--
Configure the IP Address and the Subnet Mask for the Alcatel Virtual Network Card for Lower Layers
and click OK.
3
4
5
Figure 49 - TCP/IP Configuration (Windows NT 4.0)
3CC14295AGAA TQ BJA 01
125/374
--
Click Close in the Protocols tab of the Network Control Panel applet.
The new configuration of Alcatel Virtual Network Card for Lower Layers will be used at the next restart
of the computer.
--
If you are configuring or installing the Alcatel Virtual Network Card for Lower Layers you can click Yes.
If you are installing some other component you should click No, continue the installation and restart
the computer later.
126/374
3CC14295AGAA TQ BJA 01
4.2.2.5 -- Installing the Alcatel Virtual Network Card for Lower Layers Under Windows 2000
To install the Alcatel Virtual Network Card for Lower Layers, run the Add/Remove Hardware Wizard from the
Control Panel.
Before installing and configuring Alcatel Virtual Network Card for Lower Layers you need to install the TCP/IP
protocol (please refer to Windows 2000 Help).
To configure the Alcatel Virtual Network Card for Lower Layers run the Network and Dial- up connections
applet from the Control Panel.
--
Click the Next button in the Welcome to the Add/Remove Hardware Wizard dialog box.
3CC14295AGAA TQ BJA 01
127/374
128/374
3CC14295AGAA TQ BJA 01
--
Click the Have Disk... button in the Select Network Adapter dialog box.
3CC14295AGAA TQ BJA 01
129/374
130/374
3CC14295AGAA TQ BJA 01
--
3CC14295AGAA TQ BJA 01
131/374
4.2.2.6 -- Configuring the Alcatel Virtual Network Card for Lower Layers Under Windows 2000
To configure the Alcatel Virtual Network Card for Lower Layers run the Network and Dial- up connections
applet from the Control Panel.
Before installing and configuring Alcatel Virtual Network Card for Lower Layers you need to install TCP/IP
protocol (please refer to Windows 2000 Help).
To install the Alcatel Virtual Network Card for Lower Layers run the Add/Remove Hardware Wizard from the
Control Panel.
-- Open the network connection using the Alcatel Virtual Network Card for Lower Layers from the Network
and Dial--up connections applet.
Uncheck any unnecessary component in the Properties dialog box General tab (1). Check and select
the Internet Protocol (TCP/IP) component (2) and click Properties (3).
132/374
3CC14295AGAA TQ BJA 01
1
2
3
3CC14295AGAA TQ BJA 01
133/374
--
Configure the IP Address (1) and the Subnet Mask (2) and click OK (3).
1
2
3
Figure 59 - TCP/IP Configuration (Windows 2000)
Alcatel Virtual Network Card for Lower Layers is now configured. You will need the Alcatel Lower Layers
Manager to use it.
134/374
3CC14295AGAA TQ BJA 01
4.2.2.7 -- Installing the Alcatel Virtual Network Card for Lower Layers Under Windows XP
To install the Alcatel Virtual Network Card for Lower Layers, run the Add Hardware Wizard from the Control
Panel.
Before installing and configuring Alcatel Virtual Network Card for Lower Layers you need to install the TCP/IP
protocol (please refer to Windows XP Help).
To configure the Alcatel Virtual Network Card for Lower Layers run the Network and Dialup connections
applet from the Control Panel.
-- Click the Next button in the Welcome to the Add Hardware Wizard dialog box.
3CC14295AGAA TQ BJA 01
135/374
136/374
3CC14295AGAA TQ BJA 01
Click the Have Disk... button in the Select Network Adapter dialog box.
3CC14295AGAA TQ BJA 01
137/374
--
138/374
3CC14295AGAA TQ BJA 01
--
Open the network connection using the Alcatel Virtual Network Card for Lower Layers from the Network
and Dialup connections applet.
Uncheck any unnecessary component in the Properties dialog box General tab (1). Check and select
the Internet Protocol (TCP/IP) component (2) and click Properties (3).
1
2
3
3CC14295AGAA TQ BJA 01
139/374
Configure the IP Address (1) and the Subnet Mask (2) and click OK (3).
1
2
3
Figure 67 TCP/IP Configuration (Windows XP)
Alcatel Virtual Network Card for Lower Layers is now configured. You will need the Alcatel Lower Layers
Manager to use it.
140/374
3CC14295AGAA TQ BJA 01
--
4.3
CT initial configuration
CAUTION:
S Procedures described in the following are carried out with the PC connected to the NE.
Refer to 1320 CT Basic Craft Terminal Operators Handbook, section Installation, chapter Craft Terminal
Configuration (document reference 3AL79551AAAA).
4.3.3 -- NE Login
In order to carry out procedures described in following paragraphs Craft Terminal configuration, NE Profile
management and NE software downloading preparation, the NE must be logged--in, as described below:
Craft Terminal (CT) start--up:
-- power on CT and wait for PC start--up
--
S
S
if choice 1320CT--P v.x.x.x is not available, PC is not configured as Craft Terminal: Software
Package loading is necessary
x.x.x depends on Software Package loaded
After a while, the Network Element Synthesis screen will appear, showing all Network Elements
that can be selected. After this Start operation, all NEs appear with symbol ? (it means they are
not supervised)
3CC14295AGAA TQ BJA 01
141/374
select the interested Network Element (NE) clicking once left mouse button on it;
--
while NE selected, with right mouse button choose Start Supervision and with left mouse button execute
it (click once).
Wait until the symbol ? becomes colored (it means NE in supervised state)
select the interested Network Element (NE) clicking once right mouse button on it;
--
142/374
3CC14295AGAA TQ BJA 01
Figure 70 - NE login
The Login Screen then appears.
3CC14295AGAA TQ BJA 01
143/374
---
---
144/374
3CC14295AGAA TQ BJA 01
--
4.4
This chapter details all phases necessary to install the SW in the equipment environment for the first time.
CAUTION:
S Procedures described in the following are carried out with the PC connected to the NE
4.4.1 -- Requirements
4.4.1.1 -- NE hardware
The equipment must have been already physically installed, cabled and powered on, according to the
instructions given in the:
4.4.1.2 -- Craft Terminal
The Craft Terminal, already loaded with the SW to be downloaded toward the NE, must be available together
with the 9 pin/9 pin cable and F connector adapter cable for its connection to the equipment F interface.
4.4.1.3 -- Operator skills and profile
In addition to skills stated in para.4.1.1, the Operator must be familiar with all the equipment functionalities.
With the suitable cable and F connector adapter cable, connect the PC to F interface of the MAIN unit
--
Activate ECT (1320CT x.x.x) and execute the Login to the NE (see para. 4.3.3 on page 141).
--
then, after about 1/4 hours, SW Download SW status Apply Action to activate the
software.
The software download can be performed also by using the Ethernet interface of the PC. In this case the
download lasts only few minutes.
3CC14295AGAA TQ BJA 01
145/374
4.5
--
NE Configuration
Once the software is downloaded and activated on the NE, the NE resets in order to use the downloaded
software version. This reset breaks the connection with the CT. The operator must, therefore, log in to the NE
again (see para. 4.4.1 on page 123).
NE configuration in the case of first installation is processed through the quick configuration procedure. This
procedure is launched from the CT through the menu Configuration/Quick Configuration (see para. 4.16.5 on
page 168). Follow the instructions provided on the corresponding screen. At the end of this procedure, the NE
resets and should be up and running if properly configured.
146/374
3CC14295AGAA TQ BJA 01
4.6
--
This chapter describes the organization of the 946LUX50 NE., presented after the NE login.
First the view organization is introduced, then the accessible menu options are listed.
Additional advice is given for Navigation principles.
Main
tool
bar
View
area
Management
state control panel
For the meaning of the icons in the Alarm synthesis by severity, Alarm synthesis by domain, and the
Management state control panel refer to Section 3 in this handbook.
3CC14295AGAA TQ BJA 01
147/374
External Points
--
Line Interface
--
Performance
--
Radio
--
--
Loopback
RESOURCE
TREE AREA
RESOURCE
LIST AREA
Resource--List Area: may be represented by: Tabular View (e.g., Line Interface Domain) or Graphical
View (e.g., Equipment Domain).
148/374
3CC14295AGAA TQ BJA 01
Tabular View: displays a tabular representation of the selected resource. As default, no tabular
element is shown.
Graphical View: displays a graphical representation of the selected resource. As default, no
tabular element is shown.
--
Resource--Detail Area: displays detailed information of a selected item in the Resource List area. As
a default, no entry view is displayed as a consequence of the default behavior of the Resource List area.
3CC14295AGAA TQ BJA 01
149/374
Cancel
this button closes the window without modifying the parameters displayed in the
window.
--
OK
--
Close
--
Help
this button provides help management for the functions of the supporting window.
Critical configuration choices could present a warning message asking for user confirmation before being
activated.
4.7
--
The menu bar lets you perform configuration and supervision functions on the Network Element.
This paragraph lists all menu options and then provides more details on the respective contained entries.
For each of them the relevant operative function are briefly introduced and it is referred the paragraphs where
they are detailed or the introduction to the options of each menu inserted in next paragraphs of this chapter.
From Chapter 4.8 on page 154 details and operating information on all views are given.
In the menu bar, a number of permanent menu items are always displayed. Starting from the left, the menus
are:
-- Permanent Menus
The menu bar also comprises other menus, presented only when a specific option is selected.
-- Other Menus
Equipment
This menu is present only when the Equipment menu (selected in the View menu or in the
Equipment tab panel) is active. It lets you go back to the supporting equipment of the displayed
object.
150/374
3CC14295AGAA TQ BJA 01
Open Object:
Not active.
--
--
--
Equipment:
Opens the Equipment view. Then the Equipment menu is available on the menu bar. See Chapter
4.9 on page 192.
--
External Points:
Displays and sets the input/output environmental alarm. See Chapter 4.12 on page 216.
--
Line Interface:
Opens the Line Interface view to configure all the tributary ports. See Chapter 4.10 on page 201.
--
Performance:
Lets you manage the Performance monitoring. See Chapter 4.17 on page 247.
--
Radio:
Lets you manage all the functions relevant to the radio channels. See Chapter 4.11 on page 205.
--
Protection Scheme:
Lets you manage the Protection schemes in 1+1 configuration. See Chapter 4.14 on page 221.
--
Loopback:
Lets you manage the loopbacks available with the equipment. See Chapter 4.15 on page 232.
It is possible to access directly the menus for Equipment, External Points, Line Interface, Performance, Radio,
Protection Scheme, Loopback by clicking on the relevant tab panel above the view area.
3CC14295AGAA TQ BJA 01
151/374
Tab panel
Network configuration:
See para. 4.8.2 on page 155.
--
Alarm Severities:
Manages the Alarm Severity Assignment Profile. See para. 4.8.3 on page 163.
--
System setting:
Allows system configuration, sets all the parameters for the NE setup. See para. 4.8.4 on page
168.
--
Quick configuration:
Allows a full system configuration through a guided procedure. See para. 4.8.5 on page 172.
--
Profiles management:
Manages the Security Profiles. See para. 4.8.6 on page 187.
152/374
3CC14295AGAA TQ BJA 01
Log Browsing:
Manages the events stored in the NE. (See para. 4.16.2 on page 240.) Opens the following menu
options:
Alarm log
Event log
--
--
--
Restart NE:
Reset of the NE software. See para. 4.13.2 on page 219.
--
Initi SW download:
Manages the software download to the NE. See para. 4.18.2 on page 255.
--
SW status:
Shows and manages the status of the software packages installed in the NE memory banks. See
para. 4.18.3 on page 257.
3CC14295AGAA TQ BJA 01
153/374
4.8
--
CONFIGURATION
4.8.1 - NE Time
The NE local time can be displayed and/or reset to the OS time setting.
From the Configuration pull down menu, select the NE Time option.
The following dialog box opens, from which you can set the local NE time.
154/374
3CC14295AGAA TQ BJA 01
IP Configuration:
IP static routing configuration: defines the Host/Network destination address for IP static routing
OSPF Area configuration: defines the Open Shortest Path First configuration
IP Address configuration of Point--To--Point Interfaces: defines the configuration of the interfaces
which use the PPP protocol
--
Routing information:
Displays the contents of the NEs routing table.
3CC14295AGAA TQ BJA 01
155/374
156/374
3CC14295AGAA TQ BJA 01
IP Mask:
Interface type:
lets you use point to point interfaces made available by the NE.
3CC14295AGAA TQ BJA 01
157/374
--
Point to Point Interface Index for the NMS channels (NMS--RF, NMS1--V11, NMS2--V11)
If the Default Gateway IP Address radio button has been selected in the above screen, set the Default
Gateway IP Address in the corresponding field below.
158/374
3CC14295AGAA TQ BJA 01
If the Point To Point Interface Index radio button has been selected, the following dialog box opens.
3CC14295AGAA TQ BJA 01
159/374
In the screen, enter the IP address, the IP mask and select the flag (True/False).
160/374
3CC14295AGAA TQ BJA 01
DCE
--
Codirectional
3CC14295AGAA TQ BJA 01
161/374
NMS2
Routing
NMS1
Radio
MSU1
This parameter cannot be configured in the case of NMS RF and, therefore, is always set to Not Used in this
case.
Supervision
With
946LUX50
software
NMS1 NMS2
162/374
3CC14295AGAA TQ BJA 01
Profile Primary Alarms. This profile enables the emission of the primary alarms. General rules used
to define the alarms severity:
MAJOR: the alarm affects the service (it is service affecting);
MINOR or WARNING (according to the impact of the alarm): the alarm doesnt affects the service
(with the exception of High BER alarm, for which MINOR alarm severity is defined, even if it is
service affecting).
--
Profile No Remote Alarms. This profile enables the emission of the primary alarms plus Early
Warning and Low BER alarms. This profile uses the following rules to define the alarms severity:
MAJOR: the alarm affects the service (it is service affecting);
MINOR: the alarm is potentially service affecting but a protection has recovered the service;
WARNING: the alarm cannot affect the service (independent from any protection).
--
Profile All Alarms. This profile enables the emission of all the alarms (including AIS and RDI). This
profile uses the same severity as the Primary alarm profile, the only difference is that Early Warning,
Low BER, AIS and RDI alarms are emitted.
The rules used to define the alarm severity are the same as for the Primary alarm profile.
In case of alarms affecting a protection, different severities are used for SA and NSA. The same severity is used
both for SA and NSA in case of service independent alarms.
The rules used to define the profile alarms severity described above, are not applied to the housekeeping
alarms. In this case, in order to enhance the flexibility, a different severity is assigned to each alarm profile (WAR,
MIN and MAJ).
3CC14295AGAA TQ BJA 01
163/374
Clone: to create a new Alarm Severity Profile. To create a clone refer to para. 4.8.3.1 on page 165.
--
--
164/374
3CC14295AGAA TQ BJA 01
Select the Alarm Profile to be cloned from the Alarm Severities Profile screen.
--
--
Enter the name to be assigned to the new Alarm Profile and click on Apply.
--
Select again the Alarm Severity option from the Configuration menu.
--
Select the newly created Alarm Profile (Link 1 in the following screen).
3CC14295AGAA TQ BJA 01
165/374
--
--
--
To modify the severity of an alarm, click the Service Affecting field of the appropriate alarm and select
a new severity (following screen).
166/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
167/374
--
To modify the severity of an alarm, click on the No Service Affecting field, then click on the suitable
alarm, and select a new severity as shown in the followiing screen:
To save the changes in the Alarm Severity Profile click on Apply. (By clicking on Cancel you quit the
Alarm Severity Profile screen without any change).
Link Identifier
--
168/374
3CC14295AGAA TQ BJA 01
4.8.4.1 -- NE Configuration
The user can view the NE configuration by selecting the NE Parameters tabbed panel.
The window displayed below will appear.
Modulation
2xE1
4QAM
4xE1
4QAM
8xE1
4QAM / 16QAM
16xE1
4QAM / 16QAM
1xE3 + 1E1
4QAM / 16QAM
3CC14295AGAA TQ BJA 01
169/374
Sent Value: this field is the link identifier value transmitted by the NE (allowed values: 0 to 31).
The operator choice will be applied by selecting the related Apply button.
170/374
3CC14295AGAA TQ BJA 01
4.8.4.3 -- Overhead
The Overhead tabbed panel (screen below) identifies the parameters for the management of the phone
number.
The field Phone Number in the Order Wire Configuration area allows the operator to read and write the
station number associated to the Engineering Order Wire to be used in the selective call. Possible values are:
011--999 (with no more than one zero digit in the number).
The phone number can be enabled or disabled by selecting the corresponding buttons.
The parameter will be sent to NE by clicking on the related Apply button.
3CC14295AGAA TQ BJA 01
171/374
1+1 configurations:
7 steps for the simplified configuration
12 steps for the advanced configuration (the advanced configuration can be activated in step 6)
The table below lists all the Quick Config steps involved depending on the NE configuration and the use of the
Advanced Configuration option:
Step
1+0
1+0
Adv. Config
1+1
1+1
Adv. Config
NE configuration
Tributaries
configuration
Frame
configuration
Restoration criteria
--
--
Channels
configuration
Local IP address
configuration
OSPF area
configuration
--
--
IP static routes
configuration
--
--
NMS--RF interface
configuration
--
--
NMS1--V11
configuration
--
--
10
NMS2--V11
configuration
--
10
--
11
Summary
11
12
Next: by clicking on this button the procedure goes on the next step
--
Finish: this button is active only in the last step. By clicking on this button the operator confirms the
configuration and the new parameters are sent to the equipment.
--
Cancel: by clicking on this button the operator quits the procedure without any change in the
configuration.
--
Help: by clicking on this button the operator calls the help--on line.
172/374
3CC14295AGAA TQ BJA 01
Step 1
The following screens correspond to the most complete procedure for a 1+1 configuration with the Advanced
Configuration option which includes all the Quick Configuration steps.
3CC14295AGAA TQ BJA 01
173/374
174/374
3CC14295AGAA TQ BJA 01
WARNING: In the case of a 1 + 1 configuration, only one kind of ODU can be configured for
both channels.
3CC14295AGAA TQ BJA 01
175/374
Step 2
The screen shown below provides the fields to set the Structure of the Frame configuration (Capacity and
Modulation).
The capacity implies the choice of modulation; for example, if the tributary structure is 2E1 only 4QAM
modulation scheme is supported.
The association between Capacity and Modulation is shown on page 169.
176/374
3CC14295AGAA TQ BJA 01
Step 3
Step 3 allows the operator to choose, for each tributary configured, the signal mode status. Possible values
are Unframed and Disabled.
3CC14295AGAA TQ BJA 01
177/374
Mux/Demux protection
--
HSB Tx protection
The restoration criteria values depend upon the selected configuration type in step 1 (1 + 1 HSB, 1 + 1 FD--MP,
etc.). These values cannot be modified by the operator.
For radio protection restoration criteria values, see 4.14.2.
To go to the next step click on button Next.
To go back to the previous step click on button Back.
178/374
3CC14295AGAA TQ BJA 01
Step 5
Step 5 allows the operator to define the basic parameters for each configured channel. The related screen is
shown below:
The Channel Configuration screen allows you to configure the Tx power and Frequencies of the ODU(s).
Depending on the choices made in Step 1 (configuration type, duplexer type), some values could be read only.
--
If the configuration type is 1 + 0, only one channel needs to be configured. In 1 + 1 configurations both
channels (1 and 0) need to be configured.
--
If the configuration type is 1 + 1 HSB, Tx frequency for channel 0 is automatically set according to Tx
frequency for channel 1, while Tx Power can be set independently on both channels.
--
If the configuration type is 1 + 1 FD, Tx Frequency has to be configured on both channels, while Tx
Power on channel 0 is synchronized with Tx Power on channel 1.
--
If the configured duplexer type is Other Duplexer, the Rx frequency value can be configured
independently of the Tx Frequency. In all other cases, the Rx Frequency value is deduced automatically
from the Tx Frequency and duplexer shift.
--
If the configured IDU Main Unit is not IDU Light 4x2 Mbps, and if the configured ODU is ODU UX Flat,
the ATPC mode can be enabled or disabled (otherwise ATPC is forced to disabled, due to the fact that
it is not supported).
3CC14295AGAA TQ BJA 01
179/374
Step 6
Step 6 performs the network configuration. This window allows the operator to configure the NE IP address.
180/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
181/374
If PPP Id is selected, the PPP interface used for this route has to be defined among the NEs three
PPP interfaces (NMS RF, NMS V11#1, NMS V11#2).
182/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
183/374
Figure 106 - Quick Configuration Procedure: NMS1- V11 Interface Configuration (Step 10)
Through the NMS1--V11 interface the NE can exchange management messages with an OS (or Craft
Terminal) in the same station.
The NMS1--V11 channel can be Enabled or Disabled by selection in the NMS1 V11 field.
In the Routing IP Protocol field indicate whether or not OSPF is used.
In the PPP_MODE field the following selections can be made:
DTE Mode:
Interface with equipment configured in DCE mode
DCE Mode:
Interface with equipment configured in DTE mode
Codirectional Mode:
Interface with equipment configured in codirectional mode
To go to the next step click on button Next.
To go back to the previous step click on button Back.
184/374
3CC14295AGAA TQ BJA 01
Figure 107 - Quick Configuration Procedure: NMS2- V11 Interface Configuration (Step 11)
Using the NMS2--V11 interface, the NE can exchange management messages with an OS (or Craft Terminal)
in the same station.
The NMS2--V11 channel can be Enabled or Disabled by selection in the NMS2 V11 field.
In the Routing IP Protocol field, indicate whether or not OSPF is used.
In the PPP_MODE field the following selections can be made:
DTE Mode:
Interface with equipment configured in DCE mode
DCE Mode:
Interface with equipment configured in DTE mode
Codirectional Mode:
Interface with equipment configured in codirectional mode
To go to the next step click on button Next.
To go back to the previous step click on button Back.
3CC14295AGAA TQ BJA 01
185/374
Step 12
Step 12 is the last step. The screen shown below summarizes all the parameters configured during this
procedure and some relevant parameters with default values.
186/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
187/374
--
--
--
can manage security features (add/remove users or change own password and all users
passwords).
Operator
cannot manage network configuration, only for NTP Configuration, due to dangerous isolation of
NE.
cannot do quick configuration, restart NE. Also the provisioning of equipment is not supported and
the operations that require the operator presence on the radio site.
CraftPerson
Viewer
All user--predefined profiles can be connected to NE by an F interface (local serial interface) or by a remote
interface.
Five buttons are available in the Profiles Management Screen:
-- Create: to create a new user. Refer to para. 4.8.6.1.1 on page 188.
--
Change PW: to change a user password. Refer to para. 4.8.6.1.2 on page 189.
--
--
--
188/374
3CC14295AGAA TQ BJA 01
--
--
--
Select the profile to be associated to the new user from the cascading menu (following screen).
--
--
3CC14295AGAA TQ BJA 01
189/374
--
--
--
--
--
--
--
From the confirmation dialog box that opens, you can confirm or cancel the user deletion operation.
--
--
--
Note that the initial user is a default user that cannot be deleted.
190/374
3CC14295AGAA TQ BJA 01
Select the Profiles Management option and then, from the cascading menu, the Change Password
option.
--
--
--
--
3CC14295AGAA TQ BJA 01
191/374
4.9
--
EQUIPMENT
This chapter describes the types of functions offered to the user for Equipment Management.
The equipment domain deals with the management of the NE as a whole and its physical components (subrack,
boards,...)
The main screen of the Equipment tab panel is shown below for a 1+0 Radio configuration:
Equipment Status
ODU
ODU Status
IDU
IDU Status
192/374
3CC14295AGAA TQ BJA 01
The main screen of the Equipment tab panel is shown below for the 1+1 HSB--MP.
Equipment Status
ODU
ODU Status
IDU
IDU Status
--
--
--
--
3CC14295AGAA TQ BJA 01
193/374
IDU Status
MAIN IDU BOARD
IDU
MAIN IDU BOARD Status
194/374
3CC14295AGAA TQ BJA 01
IDU
IDU Status
EXTENSION IDU
BOARD Status
Extension board
3CC14295AGAA TQ BJA 01
195/374
BOARD Status
196/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
197/374
198/374
3CC14295AGAA TQ BJA 01
4.9.1.3 -- Alarms
The Alarms tab panel provides the fault mangement, which checks the current state of alarms related to the
selected object: (See Appendix 7, page 357.)
--
--
--
3CC14295AGAA TQ BJA 01
199/374
4.9.1.4 -- Configuration
The User Label field displays the label associated to the selected node in the tree.
The field Alarm Profile allows to associate to the object alarms a particular Alarm Profile: a default alarm profile
or an Alarm Profile previously created by the Operator (refer to para. 4.8.3.1 on page 165). To associate a
different Alarm Profile click on the selection button and make the selection among the available Alarm Profile.
The default associated Alarm Profile is the Primary Alarm profile.
200/374
3CC14295AGAA TQ BJA 01
4.10
--
LINE INTERFACE
This chapter describes the type of functions available for Line Interface Management.
4.10.1 -- Tributaries
The Line Interface domain deals with the management of the aggregate frame and tributary ports (line side).
The Line Interface view allows the user to manage the resources of a PDH signal, i.e., frames, tributary ports
(line), etc.
-- This domain view consists of the following areas:
Resource Tree Area: displays the frames and tributary ports sorted by the channel number.
Resource List Area: displays tabular information about the selected resource in the tree area.
Resource Detail Area: displays, through tabbed windows, the selected objects properties in the
list area. This area allows you to execute the available commands for the selected resource.
Port Number: the port for a given channel and type of port
--
--
--
To change the Signal Mode, select the tributary and change the Signal Mode field in the Resource Detail Area.
3CC14295AGAA TQ BJA 01
201/374
4.10.1.1 -- Alarm
The fault management checks the current state of alarms related to the selected tributary.
It is provided by the alarm panel like the one explained in para. 4.9.1.5.
4.10.1.2 -- Configuration
The window shown below gives you access to all available functions for a tributary port.
The managed tributary types are E1 and E3.
To define the involved ports, the channel must be selected in the tree view. Consequently, the selection of the
desired tributary port in the tabular view allows the Resource Detail List to show the available functions for the
individual resource.
Port Number: the port for a given channel and type of port
--
Alarm Profile
Signal Mode
The possible values are:
-- Unframed
--
Disabled
The current state can be modified by selecting a different signal mode value and then clicking on the Apply
button to send the new value to the NE.
Alarm Profile
The Alarm Profile field lets you associate a particular Alarm Profile with the tributary alarms: a default alarm
profile or an Alarm Profile previously created by the operator (refer to para. 4.8.3.1). To associate a different
Alarm Profile, click on the selection button and select from among the available profiles.
The default associated Alarm Profile is the No Alarm profile.
202/374
3CC14295AGAA TQ BJA 01
4.10.1.3 -- Test
The Test tab allows you to perform certain tests on the selected tributary by inserting a pseudo random binary
sequence (PRBS) into this tributary at the transmission side and by measuring the Bit Error Rate on its reception
side.
3CC14295AGAA TQ BJA 01
203/374
Using the Alarms tab, the operator can check if an alarm is present on the selected NMS interface. The
operator can also change the alarm profile for each of the NMS interfaces through the Configuration tab
204/374
3CC14295AGAA TQ BJA 01
4.11
--
RADIO
The Radio domain view allows the user to manage the resources of the radio transmission channel.
A Radio NE consists of one or two radio channels with a set of functional blocks (tributary ports, radio ports etc).
This domain view consists of the following areas:
--
Resource Tree Area: displays the radio ports sorted by channel number.
--
Resource List Area: displays tabular information about the selected resource in tree area.
--
Resource Detail Area: displays, through tabbed windows, the object s properties selected in the list
area. This area allows you to execute the available commands for the selected resource.
Alarms: shows the active alarms (refer to para. 4.11.1 on page 206)
--
Configuration: configures some radio parameters (refer to para. 4.11.2 on page 206)
--
Frequency: sets the Tx/Rx RF frequency (refer to para. 4.11.3 on page 207)
--
RTPC & ATPC: sets the Tx Power (refer to para. 4.11.4 on page 208)
--
Power Meas: performs the Tx and Rx power measurements (refer to para. 4.11.5 on page 210).
--
BER Meas: refers to BER measurement (refer to para. 4.11.6 on page 215)
3CC14295AGAA TQ BJA 01
205/374
4.11.1 -- Alarm
The fault management allows you to check the current state of the alarms related to the selected object.
It is provided by the alarm panel like that shown in para. 4.9.1.3 on page 199.
4.11.2 - Configuration
The Radio Frequency window gives you access to all the available functions for a Radio PDH port.
To define the involved port, first select the port/channel in the tabular view: this selection enables the Resource
Detail list to show the available functions for the single resource.
4.11.2.1 -- Tx Local Mute
The information related to the transmitter status is shown in the Status field. To change the transmitter status
choose the desired value (ON for Tx Squelched and OFF for Tx not Squelched) and press the related Apply
button.
When Tx Local Mute is activated, an abnormal condition is raised on the channel in order to remind the operator
that the NE is currently not working in normal condition. This abnormal condition disappears when the Tx Local
Mute is stopped.
4.11.2.2 -- Alarm Profile
The field Alarm Profile allows to associate a particular Alarm Profile to the object alarms: a default alarm profile
or an Alarm Profile previously created by the Operator (refer to para. 4.8.3.1 on page 165). To associate a
different Alarm Profile click on the selection button and select among the available Alarm Profile.
The default associated Alarm Profile is the Primary Alarm profile.
206/374
3CC14295AGAA TQ BJA 01
4.11.3 -- Frequency
This menu lets you read and, if necessary, set the frequency parameters.
The information shown concerns the port/channel selected in the Resource Tabular View.
3CC14295AGAA TQ BJA 01
207/374
To work properly, the ATPC must be put in operation in the local and remote stations.
When ATPC is disabled, the active part of the screen is the RTPC area. Refer to paragraph
4.11.4.2.
When ATPC is enabled (if IDU and ODU alow it), the active part of the screen is the ATPC
area. Refer to paragraph 4.11.4.1.
In ATPC mode, when the modulation is changed from 4QAM to 16QAM, the ATPC mode is
automatically de--activated. It is necessary to reactivate the ATPC mode in operational
configuration after the change of modulation.
4.11.4.1 -- ATPC
208/374
3CC14295AGAA TQ BJA 01
--
ATPC Max Value parameter allows to define the maximum Tx power level at which the NE is
authorized to transmit. The ATPC min value is read--only is defined by the ODU performance (ATPC
range, cf. 2.8). Practically, the minimum Tx power can also be limited by the link characteristic
(free space attenuation too important).
--
ATPC Rx Threshold parameter defines the Rx power level below which the ATPC regulation loop
will start increasing the transmission power level in order to compensate for the low Rx power level.
On the other hand, the ATPC regulation loop will start decreasing the transmission power level when
the measured Rx power level goes above (ATPC Rx Threshold).
Note: The ATPC Rx Threshold must be choosen considering the link budget. For example, if the
threshold is too high, the remote transmitter will permanently remain at maximum power. As a rule of
thumb, it is recommended to choose a value within - 55 dBm and 10 dB above the 10- 6 BER threshold.
4.11.4.2 -- RTPC
3CC14295AGAA TQ BJA 01
209/374
210/374
3CC14295AGAA TQ BJA 01
By selecting Create File the log file is created and a default path and name for this file is displayed to the
operator. The file is stored in the ALCATEL/CT--Kv3.0.3 directory.
The log file contains the sample value and records the measurement up to a maximum dimension ( 7 days for
a 2 second sample time).
By clicking on the Start button the screen Power Measurement Graphic appears.
The Power Measurement Graphic is available only if the CT is connected to the NE.
The screen shows the Tx and Rx measurements related to the local NE:
Using this screen the operator can see, in real time, the power transmitted by the local transmitter (Tx) and the
power received by the local receiver (Rx).
If ATPC mode is enabled, the Tx Power displayed in Power Measurement Graphic does not reflect the actual
Tx Power value but the ATPC Max value.
If ATPC mode is disabled, the Tx Power displayed in Power Measurement Graphic is the RTPC power
transmitted by the local transmitter.
The top graphic screen area shows the TX curve, while the bottom area shows the Rx curve.
The top of the screen offers all the characteristics present in the current measurement:
-- Radio channel: gives the symbolic name associated to the radio channel being analyzed;
--
Sample time: indicates the frequency used to send the measurement requests to NE;
--
--
Stop time: is the interval time selected in the previous parameters window, added to the start time;
--
--
Log File: is the complete pathname of the file where the received values are stored.
3CC14295AGAA TQ BJA 01
211/374
By clicking on Show details box, on the left side of the Power Measurement Graphic, a new table appears:
--
Max TX local value and date when this value was received for the first time.
Min. TX local value and its current date when this value was received for the first time.
Rx Local End
Max Rx local value and date when this value was received for the first time.
Min. Rx local value and its current date when this value was received for the first time.
212/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
213/374
The button in the lower part of the window lets the graph display changes within the measurement interval.
Select the .txt file and click with the right mouse button to open the .txt file with a text editor (e.g. WordPad) and
see the power information in tabular mode:
214/374
3CC14295AGAA TQ BJA 01
The BER Measures screen allows the operator to set initial parameters for the required measure.
Sample Time field defines the period between two consecutive measure samples.
Clicking on Start button triggers the measurements.
Displayed values are the Current BER measure value, along with Min and Max BER measure values,
corresponding to minimum and maximum BER values encountered since the beginning of the measure.
Measures will go on until the operator clicks the Stop button.
3CC14295AGAA TQ BJA 01
215/374
4.12
--
EXTERNAL POINTS
This chapter describes the types of functions offered to the user for External Points Management.
There are two types of external points: input and output external points.
When you click on the tree root, the tree will be expanded according to the equipment configuration.
A single left click selection of a tree element causes the activation of the corresponding Tabular representation
displayed in the Resource list area. A click on a row in the Resoure list area opens the Configuration menu
in the Resource Detail Area.
--
--
The lower part provides the possible parameters, which can be modified; after a row selection, the user can
modify the User Label and can associate a different Alarm Profile by clicking on the Selection button.
The operator choices will be sent to NE after selecting the Apply button.
216/374
3CC14295AGAA TQ BJA 01
--
The lower part provides the possible parameters which can be modified; after a row selection, the user can
modify the User Label and External State of the external point selected (On=active; Off=not active).
The operator choices will be sent to NE by clicking on the Apply button.
3CC14295AGAA TQ BJA 01
217/374
4.13
--
SUPERVISION
Performance processing,
--
Figure 143 - Craft access state configuration from the Equipment NE view in OS mode
The request is sent up to the OS which accepts or refuses it.
If the OS doesnt answer in a predefined time, it is assumed that the NE is in the Craft access state and can be
managed by a Craft Terminal.
218/374
3CC14295AGAA TQ BJA 01
4.13.1.2 -- Switching from the Craft Terminal access state back to the OS access state
Select the Supervision pull down menu. Then from the Access State cascading menu, select the OS option.
From the confirmation dialog box that opens, you can confirm or cancel the OS access operation.
The NE is now managed by the OS.
The key symbol icon on the management states of the NE view indicates whether the NE is managed by a craft
terminal or by the OS.
Local Craft Terminal access is denied on recovery phase after a loss of communication of the NE. When the
communication with the NE is lost, the OS automatically recovers the communication and forces the state
existing before the loss of communication (therefore, Craft Terminal access can be denied or granted).
4.13.2 - Restart NE
The RESTART operation is a software reset and can be executed in normal traffic conditions.
From the Supervision cascading menu, select the Restart NE option.
3CC14295AGAA TQ BJA 01
219/374
220/374
3CC14295AGAA TQ BJA 01
4.14
--
PROTECTION SCHEMES
Resource List Area: displays tabular information about the selected resource in tree area.
--
Resource Detail Area: displays, through tabbed windows, the properties done in list area. This area
allows you to perform the available functions for the selected resource.
By clicking on the tree root shown below, the tree will be expanded according to the supported protection
schemes.
A single left click selection of an element tree causes the activation of the corresponding graphical
representation displayed in the Resource list area.
Three 1+1 protection schemes are available, depending on the NE configuration:
-- Mux/Demux protection: EPS protection in Tx side
--
--
To see the current position of the switches enter the menu Diagnosis --> Summary Block Diagram View (refer
to para. 4.16.5 on page 242).
-- The Mux/Demux protection corresponds to the Switch Tx
--
3CC14295AGAA TQ BJA 01
221/374
--
The HSB protection is implemented in the ODU: one Transmitter is connected to the antenna (active),
the other transmitter is in standby.
--
The Criteria column provides information related to the event that triggered the last switch from the
corresponding channel. This is not an alarm. For instance, after startup this criteria may be set, in some
cases, to Equipment Failure even if no such event actually happened.
Channels Parameters
Protection Type: this parameter is defined at configuration time and it is read only. The supported type
is: 1+1, e.g. a working channel (Main) is protected by a protecting channel (Spare).
--
The operator choice for Operation Type will be applied by clicking on Apply button.
222/374
3CC14295AGAA TQ BJA 01
4.14.1.2 -- Commands
To enter the Commands menu click on the Spare #0 element in the Tree view or on the Main #1 element.
3CC14295AGAA TQ BJA 01
223/374
You can modify the state of the switch with the Lockout, Forced and Manual commands.
Lockout has higher priority than Forced: the activation forces Channel 1 into service independently of the
possible active alarms. This command activates signaling AC (Abnormal Condition).
Forced has higher priority than the automatic operation: the activation of this command forces in service
Channel 0, independently of the possible active alarms. This command activates signaling AC.
Automatic Switch is the normal operation condition: the position of the switch depends on the commands
generated by the logic.
Manual has the lowest priority: it is performed only if there are no alarms that can activate an automatic switch.
It cannot be performed if Lockout or Forced commands are already activated. If this command is active, it will
be removed by an incoming alarm. This command does not activate signaling AC.
Command priority list
Command
Priority
Lockout
Forced
Automatic switch
Manual
224/374
3CC14295AGAA TQ BJA 01
Operation Type field: always indicates notRevertive while actually automatic radio protection always
tries to give priority to the channel with the best reception quality.
3CC14295AGAA TQ BJA 01
225/374
--
Early warning on Rx Power Level: Defines the absolute received power level at which the Early
Warning alarm is triggered.
Early warning on BER: Defines the BER threshold at which the Early Warning alarm is triggered.
S
--
Defines the BER threshold at which the low Bit Error Ratio switching request alarm is triggered.
226/374
Selects the BER threshold at which the high Bit Error Ratio switching request alarm is triggered.
The selected error rate determines the AIS engagement.
3CC14295AGAA TQ BJA 01
4.14.2.3 -- Commands
To enter the Commands menu click on the Spare #0 element in the Tree view or on the Main #1 element.
3CC14295AGAA TQ BJA 01
227/374
Priority
Lockout
Forced
Automatic switch
Manual
228/374
3CC14295AGAA TQ BJA 01
Channels Parameters
Operation type: Shows the automatic restoration criteria from the protecting to the protected unit.
In the case of 1+1 HSB--SD and 1+1 HSB--SD--MP configurations (space diversity: 2 antennas).
Operation type is not revertive (automatic restoration inhibited).
In case of 1+1 HSB and 1+1 HSB--MP (1 antenna and 1 coupler): Operation Type is revertive
(automatic restoration allowed).
The operator choice for Operation Type will be applied clicking on Apply button.
3CC14295AGAA TQ BJA 01
229/374
4.14.3.2 -- Commands
To enter the Commands menu click on the Spare #0 element or on the Main #1 element in the Tree view.
230/374
3CC14295AGAA TQ BJA 01
Priority
Lockout
Forced
Automatic switch
Manual
3CC14295AGAA TQ BJA 01
231/374
4.15
--
LOOPBACKS
The functions described in this section allow to perform the test operations.
This domain view consists of the following areas:
-- Resource Tree Area: displays the object on which the loopbacks can be performed, sorted by number.
--
Resource Filter Area: displays the possible filters to apply to loopback search.
--
Resource List Area: displays tabular information about the loopback supported by the resource
selected in tree area.
--
Resource Detail Area: displays, through tabbed windows, the properties done in list area. This area
enables to perform the available functions for involved resource.
CT
IDU
ODU
2
TRIB
MUX/
DEMUX
ODU
IDU
MODEM
RF
RF
MODEM
MUX/
DEMUX
TRIB
232/374
3CC14295AGAA TQ BJA 01
--
--
--
--
3CC14295AGAA TQ BJA 01
233/374
Figure 160 gives the relationship of all the possible loopbacks and their positions in the block diagram of the
equipment provided by the Summary Block Diagram View option, available in the Diagnosis menu.
IDU
CABLE
ODU
CABLE
4 Radio
port
(RF loop)
E1/E3 Port # xx
Clicking on a L square in the Summary block diagram view alllows you to navigate directly to the loopabck
configuration screen.
Tab. 1. 1+0 Loopbacks
No.
Loopback
name
CT selection in
the Resource
Tree Area
Ref. to
Fig.
Location
Loopback
type
Note
E1/E3
Port#xx
Channel 1
160
Near End
Internal
IDU cable
Channel 1
160
Near End
Internal
ODU cable
Channel 1
160
Near End
Internal
Radio port
Channel 1
160
Near End
Internal
RF local loopback
234/374
3CC14295AGAA TQ BJA 01
--
Location: the station in which the loopback is performed (Near End/Far End)
--
--
--
In Figure 162 is given the association of all the possible loopbacks and their positions in the block diagram of
the equipment provided by the Summary Block Diagram View option, available in the Diagnosis menu.
3CC14295AGAA TQ BJA 01
235/374
IDU
CABLE
ODU
CABLE
4
Radio port
(RF loop)
E1/E3
Port # xx
Loopback
name
CT selection in
the Resource
Tree Area
Ref. to
Fig.
Location
Loopback
type
Note
E1/E3
Port#xx
Channel 0 or 1
162
Near End
Internal
IDU cable
Channel 0 or 1
162
Near End
Internal
ODU cable
Channel 0 or 1
162
Near End
Internal
Radio port
Channel 0 or 1
162
Near End
Internal
RF local loopback
236/374
3CC14295AGAA TQ BJA 01
--
Click on Apply.
--
In the row in the Resource List Area the Activation field of the relevant loopback changes from Not
Active to Active.
When loopback activation is activated, an abnormal condition is raised on the tributary in order to remind the
operator that the NE is currently not working in normal condition. This abnormal condition disappears when the
loopback activation is stopped.
3CC14295AGAA TQ BJA 01
237/374
--
Click on Apply.
--
In the row in the Resource List Area the Activation field of the relevant loopback changes from Active
to Not Active.
238/374
3CC14295AGAA TQ BJA 01
4.16
--
DIAGNOSIS
4.16.1 -- Alarms
In the diagnosis pull--down menu, select the Alarms/NE Alarms options. This opens the Alarm Surveillance (AS)
application, allowing managment of the NE alarms.
3CC14295AGAA TQ BJA 01
239/374
240/374
3CC14295AGAA TQ BJA 01
--
Select the Event Log option to access the Event Log file.
The Event Log window opens, permitting to analyze all the events stored in the NE.
Refer to the 1320 CT Operators Handbook (Alcatel Ref. 3AL79552AAAA).
3CC14295AGAA TQ BJA 01
241/374
Loopbacks
--
--
242/374
3CC14295AGAA TQ BJA 01
--
--
navigate from Loopback indicator to specific Loopback view; for example, by clicking on (L)
indicator of main board (Ch#1) the operator can navigate to loopback view for IDU cable;
--
navigate from Performance indicator to specific Performance view; for example, by clicking on (P)
indicator (line side) the operator can navigate to Current Data view;
--
navigate from ODU box to the radio view with automatic selection of the related channel.
In the 1+1 configuration the current position of the switches is also shown.
3CC14295AGAA TQ BJA 01
243/374
Figure 173 - Summary Block Diagram View: 1+1 HSB with Mux/Demux protection
244/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
245/374
246/374
3CC14295AGAA TQ BJA 01
--
4.17
PERFORMANCE MONITORING
This chapter describes the functions to provide Performance Monitoring (PM) management. It explains the
procedures that the operator must perform in order to activate a PM process.
CAUTION:
S In order to avoid discrepancies between performance monitoring data timestamp
and PC current time, first make sure that date and time are in sync between the NE
to be monitored and the PC running the craft terminal (refer to section 4.8.1 for NE
time configuration).
CAUTION:
S With the analog cable interface, the G.826 counters are not correctly evaluated.
FEC
ENCODE
MODEM
RF
MODEM
RF
FEC
DECODE
PROPR.
FRAMING
Radio Hop
Figure 176 - Radio section
The counters supported are the following:
-- Errored Seconds
---
--
Unavailable Seconds
The following table provides, for each frame structure, the main features useful to define a SES.
Tab. 3. SES Thresholds
Gross bit rate
[MHz]
G.826 Block size
Blocks per sec.
SES Threshold
(Note 1)
E3
16E1
8E1
4E1
2E1
39,498
39,498
19,748
9,874
4,537
4937
4937
4937
4937
4937
1481
1481
1481
1481
1481
(Note 1)
Note that according to ITU--T G.826 a second is
declared a Severely Errored Second if it is a period of one second with
more than 30 % errored blocks or at least one defect.
3CC14295AGAA TQ BJA 01
247/374
The flow chart shown below illustrates the recognition of anomalies, defects, errored blocks, ES and SES
according to ITU--T G.826 (12/2002).
Monitored
second
Yes
Defects?
No
No
Anomalies?
Yes
%EB 30?
ES
(but not a SES)
Yes
SES
(and therefore an ES)
No
Path in
available
State?
No
Yes
cES = cES + 1
Path in
available
State?
No
Yes
cES = cES + 1
cSES = cSES + 1
T1313790--98
End
Figure 177 - Anomalies, defects, errored blocks, ES and SES according to ITU- T G.826
248/374
3CC14295AGAA TQ BJA 01
Resource List Area: displays the PM management for the selected resource in the tree area.
24 hours
The following description explains the functions to provide the PM process with a granularity period of 15 min.
The same functions are provided for 24h PM process.
The PM are only of HOP type. The current report can be seen (and configured) and the history PM log can be
seen.
To see and configure the current report:
-- Click on the channel (0 or 1) (in 1+0 configuration channel 1 only)
--
Click on HOP
--
3CC14295AGAA TQ BJA 01
249/374
--
Click on HOP
--
--
Each PM is associated with a threshold table. To see which threshold table is used click on HOP in the Resource
Tree Area. The following screen will appear:
250/374
3CC14295AGAA TQ BJA 01
End Period: displays time of the PM in the graphical description and in the tabular description in the
upper part of the screen. By pressing the Refresh button this time changes.
--
Max Interval supp.: max. number of intervals (reports) which can be suppressed in the History
because they dont have errors.
Num. Interval supp.: number of intervals (reports) suppressed in the History because they dont
have errors.
--
4.17.3.2 -- CD Counters
The fields and buttons displayed in the lower part of the Current Data View screen (Counters Area) allow
management of performance events.
3CC14295AGAA TQ BJA 01
251/374
In the left part of Counters Area, there is a graphical description of the event counter value: BBE (Errored block),
ES (Errored second), SES (Severely Errored Second), UAS (Unavailable second).
These values refer to the last refresh performed by pressing the Refresh button.
In the right part of screen, there are button choices to perform actions on the current data collection:
-- Reset button resets the data collection and related counters.
--
Start button starts the counters for the data collection, when the CD has been stopped.
--
--
Stop button stops the counters for the data collection, when the CD has been started.
--
Suspect interval: this field describes whether the History Data is suspect or not.
--
Counters: the last columns hold the counters value (BBE, ES, SES, UAS).
252/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
253/374
254/374
3CC14295AGAA TQ BJA 01
4.18
--
Software Download
Password: ftp
--
--
Port: 15000
The System Default can be changed by writing different values in the fields and then by clicking on button OK.
3CC14295AGAA TQ BJA 01
255/374
256/374
3CC14295AGAA TQ BJA 01
4.18.3 - SW Status
This menu allows to display the information of the software installed in the NE.
The following information is displayed:
-- Name: software name
--
--
--
By clicking on the Software Units Status button the SW Status screen, giving additional information on the
software package.
3CC14295AGAA TQ BJA 01
257/374
258/374
3CC14295AGAA TQ BJA 01
3CC14295AGAA TQ BJA 01
259/374
5 -- Commissioning
A very precise knowledge of the link configuration is absolutely vital before you
begin commissioning. For this, complete the sheets for stations A and B according to the model supplied in Appendix 2.
STOP
--
5.1
The commissioning operations described below are for a link comprising a station A and a station B.
STATION A
STATION B
Network
Network
--
commission station A,
--
--
commission station B and point the antenna, connect the tributaries and the service channels,
--
carry out all the commissioning checks (switching to local supervision mode),
EQUIPMENT REQUIRED
The following equipment is required for commissioning:
-- Multimeter.
-- Portable PC running the supervisory software (see 4.1).
-- PC-NE link cable and F interface adapter cable, supplied with the system CD--ROMs.
-- A service kit (for measuring AGC and the telephone link between the IDU and the ODU).
-- A 2 Mbit/s or 34 Mbit/s BER analyzer, with an impedance of 75 or 120 , depending on the configuration
of the link to be installed.
-- A compass and a pair of binoculars.
-- Tools as defined in 3.3.3.
3CC14295AGAA TQ BJA 01
261/374
--
5.2
Light IDU
Install station A according to the instructions in section 3, and in particular those in 3.5.3.4 or 3.5.4.4
describing how to roughly point the antenna of station A towards station B.
--
Check that the correct power supply voltage is present (24 or 48 V), with the correct polarity, on the
power supply outlet.
--
NOTE: Make sure that the IDU--ODU cable connection is removed in order to verify via the CT the
System Tx Power and Frequency settings before powering up the ODU.
--
In the case of a configuration with classic IDU, check that a software features key enabling the
configuration is connected to the SKU/MTN connector (refer to 3.2, Comments on the information
marked on the software key label).
262/374
3CC14295AGAA TQ BJA 01
--
Connect the PC to the equipment using the interface cable and F adapter cable supplied (serial port
-- connector marked F on the IDU ).
--
Wait for the ATT, URG and NURG LEDs to start flashing out of sync on the main IDU. The LED flashing
occurs if IDU and ODU have never been configured together (otherwise, refer to 4). Download the
IDU configuration, by pushing switch to the IDU setting (IDU configuration taken as a reference).
After two minutes at most (for the configuration to be registered), the LEDs should stop flashing
simultaneously.
Run LUX50 1320 CT software on the PC. Once connected to the IDU, the IDU configuration can be
done by running the Quick Configuration procedure (refer to section 4.8.5 on page 172).
Connect the 2 or 34 Mbit/s BER analyzer (according to the configuration) to an active tributary.
From the CT, select the Loopback tab, and click on the IDU Cable in the tree on the left. Select
Active and click on Apply to activate the IDU baseband loop.
Check the bit error ratio. If zero, continue checking; otherwise, check the wiring, that the LAU and
LIU boards of the unit match (and their impedances) and the configuration of the equipment. If everything is OK, change the IDU.
Cancel the IDU baseband loop. Select Not Active and click on Apply button.
Check the bit error ratio. If zero, continue checking; otherwise, check the state of the IDU/ODU link
coaxial cable.
Check the bit error ratio. If zero, continue checking via operation 10; otherwise, check the radio
configurations and correct the configuration errors.
10
11
Check that there are no remote controls still active (the AC indicator on the right should be green).
12
From the CT, select the Radio tab. The light in front of the Radio node in the Radio tree should
appear in green.
13
If an alarm is detected or an incorrect value is found, refer to section 6 and correct as required.
14
3CC14295AGAA TQ BJA 01
263/374
Connect the 2 or 34 Mbit/s BER analyzer (according to the configuration) to an active tributary.
From the CT, click on the Protection Schemes tab. For each protection (depending on the
configuration, protections can be: Radio Protection, HSB Tx Protection, Mux/Demux
Protection), select the Spare#0 node in the tree, and then select Lockout + Apply in order to
force operations on channel 1.
On channel 0, carry out operations in 5 to 11 in section 5.2.4.1 for a basic 1+1 HSB configuration,
operations 2 to 11 in section 5.2.4.1 for a 1+1 HSB configuration with multiplexer protection.
Cancel forcing on channel 0 via the remote controls Command: None + Apply on Main#1 for
each protection.
Check that there are no remote controls still active (the AC indicator on the right should be green).
From the CT, select the Radio tab. The light in front of the Radio node in the Radio tree should
appear in green.
If an alarm is detected or an incorrect value found, refer to section 6 and correct as required.
264/374
3CC14295AGAA TQ BJA 01
--
5.3
Commission station B by carrying out the same operations as those described for station A in
5.2.1 to 5.2.4, apart from the RF loop operations.
6
Elevation locking screw
Elevation
turnbuckle
Rough Azimuthal
locking screw
Azimuthal locking
screw (x4)
Azimuthal turnbuckle
Attach the hook of the service kit (ref. 9400UXT102) in the window of the Pole mounting.
--
Connect connector P01 (see Appendix 4) to the MAINT port on the front panel of the ODU.
--
Check the tightness of the two rough pointing screws and , tighten with a 5 mm Allen key.
--
Connect the voltmeter, set to DC range, to P02/P03 of the service kit 9400UXT102 or to P02/P03 of
the service kit 3EJ04113AAAA113. With the two turnbuckles, fine tune the azimuthal and elevation
settings (Figure 192) to obtain a maximum voltage on the voltmeter (AGC DC voltage of between 0 and
5 V).
--
Retighten the two azimuthal locking screws using the box wrench.
--
Tighten the four front elevation screws using the 5 mm Allen key (tighten in criss--cross fashion).
--
Finish the operation by tightening the azimuthal and elevation turnbuckle lock nuts with the 16 mm flat
wrench.
CAUTION: For the tightening torques of the screws, refer to chapter 3.3.4.
3CC14295AGAA TQ BJA 01
265/374
2
Elevation turnbuckle
1
3 screws elevation tightening
Grounding connection
Azimuthal turnbuckle
--
--
Connect the voltmeter, set to DC Volts, to P02/P03 of the service kit 9400UXT102 or to P02/P03 of
the service kit 3EG04113.
--
Be sure that the three screws { and the four screws | are a bit slackened, just enough to allow
movement of the different parts of the pole mounting. These screws must not be too much slackened,
otherwise, the fine--tuning of alignment will be imperfect. Use the 8 mm Allen key.
--
With the two turnbuckles and the 16 mm flat wrench, fine tune the elevation and azimuthal settings until
you obtain the maximum voltage reading in the voltmeter.
--
Using the local loop configurations (apart from the RF loop), repeat the operations carried out on station
A (see 5.2).
--
From the CT, run the Power Measures application (Radio tab, then the Power Meas tab).
--
Check that the received power level is greater than --90 dBm. This check must be carried out on the
normal channel and, if appropriate, the standby channel.
--
If the received power is less than this value, the reason is probably an antenna coarse pointing problem
or a transmission problem in station A.
Connect the tributary, supervision and ESC cables previously disconnected.
--
If an operator is available in another station of the network and there is a telephone in station B, test
the telephone ESC (general call using number 00).
--
Test the ESC 3, ESC 4 and ESC 5 connections, if applicable, and if the corresponding equipment is
installed in the station.
266/374
3CC14295AGAA TQ BJA 01
--
5.4
Adjust the orientation of the antenna in the same way as for station B (see 5.3.2).
Connect the CT to station A and check that there is no remaining equipment alarm (EQP alarm
synthesis indicator should be green).
--
Check that there is no remaining transmission alarm (TRS alarm synthesis indicator should be green).
If some transmission alarms remain, use the Radio and Line Interface tabs to investigate the cause
of the alarms and, if necessary, correct it.
--
Select Radio tab and then Power Meas tab in order to retrieve the received power level value. Write
down this value. This operation has to be performed on both radio channels (Channel#1 or
Channel#0 in the Radio Channels tree).
--
The received power levels should match the nominal received power indicated on the station configuration sheet
to within 6 dB. If the difference is greater:
S Check that there are no abnormal propagation conditions (storm or heavy rainfall, for example).
In the case of a 1+1 HSB configuration with integrated coupler, use the Protection Schemes tab
on each station to check that the standby channel is not being used for reception and/or
transmission.
Check the pointing of the antennas (if necessary, pointing to a secondary lobe).
If the problem persists, contact the network administrator or Alcatel customer service.
If some transmission alarms remain (TRS alarm synthesis indicator), proceed as follows for the stations with
an alarm condition:
-- Connect the CT to the station.
--
--
In case of configuration errors (tributaries incorrectly set to Unframed or Disabled, for example), use
the Line Interface and Radio tabs to make the necessary changes.
Be careful not to disconnect the link by setting the parameters incorrectly!
--
Select the E1/E3 port#xx (xx : the number of the tributary on which the loop is set up).
In station A, connect the BER analyzer to the port of tributary x and check that there are no errors.
3CC14295AGAA TQ BJA 01
267/374
CHANNEL
Main#1
1+1 FD CONFIGURATIONS
Check that the switchover is completed (see the graphic representation for stations A and B using the
Diagnosis/Summary Block Diagram View menu.
CHANNEL
Spare#0
1+1 FD CONFIGURATIONS
Check that the switchover is completed (see the graphic representation for stations A and B using the
Diagnosis/Summary Block Diagram View menu. The above note still applies.
Reinstate automatic switching mode by cancelling the remote controls previously activated as
described below:
PROTECTION
HSB Tx
Protection
CHANNEL
1+1 FD CONFIGURATIONS
Spare#0
CHANNEL
1+1 MP CONFIGURATIONS
MUX/DEMUX
Spare#0
Command Lockout + Apply
P t ti
-- Check that the switchover is completed (see the graphic representation for stations A and B using the
Diagnosis/Summary Block Diagram View menu).
-- MUX switchovers cause a microinterruption of the link which results in the appearance of error bursts.
-- Check that there are no errors (after traffic has stabilized on the normal MUX).
-- In both stations, initiate a switchover to the standby multiplexer as described below:
PROTECTION
MUX/DEMUX
P t ti
Protection
268/374
CHANNEL
1+1 MP CONFIGURATIONS
Spare#0
Main#1
3CC14295AGAA TQ BJA 01
--
Check that the switchover is completed (see the graphic representation for stations A and B using the
Diagnosis/Summary Block Diagram View menu).
--
--
PROTECTION
MUX/DEMUX
Protection
CHANNEL
1+1 MP CONFIGURATIONS
Main#1
Select the Performance tab on the CT(see 4.17.2). This application keeps a counter (errored
seconds, severely errored seconds, background block errors and unavailable seconds) on the hop
(results given for each hop and link).
4 Mbit/s
8 Mbit/s
16 Mbit/s
34 Mbit/s
ES
SES
UAS
BBE
NOTE:
If fading is observed over a period of less than 15 minutes, the fading period is not taken into account.
If fading is observed over a period of longer than 15 minutes, the test will be extended as required.
In the tree, select the E1/E3 Port#x entry corresponding to the tributary which is looped back.
--
--
Check that there are no remote controls still active (AC indicator on the CT should be green).
3CC14295AGAA TQ BJA 01
269/374
270/374
3CC14295AGAA TQ BJA 01
6.1
Preventive maintenance
This kind of maintenance is performed when carrying out a corrective maintenance procedure, or on a routine
visit to all the equipment of the station. It involves inspecting the units and their interconnections (connectors,
cables, sockets, etc), as well as all the equipment involved in the operation of the station (power supply,
batteries, solar panels, earthing, etc) and, in case of doubt, checking the suspect parts, taking all the necessary
precautions to avoid disrupting data transmission over the link (using the 1+1 switching capability if available,
etc). Preventive maintenance is recommended for the following units:
-- MCU board battery:
S every 7 to 10 years (see 7.15.1).
--
Fan unit:
S every 2 to 3 years or in case of alarm.
The system uses 2 fans. An alarm occurs when one fan fails. Both fans should be changed at the
same time (see 7.15.2).
If a main IDU and an extension IDU are used in accordance with chapter 3.4.2.2 recommendations (1U
separation) this preventive maintenance could be forgotten.
--
6.2
Corrective maintenance
6.2.1 -- Methodology
----
Check the condition of the cables, connectors and connections, and of all the components that are
involved in the operation at the station (power supply, battery, earthing, etc),
Analyze the IDU alarm indicators,
If alarms are indicated, locate them using the Craft Terminal alarm indicators and analyze them and
carry out the necessary corrective procedures (change of unit, module, cable, etc).
URG, NURG and ATT LEDs flashing simultaneously: the configurations of the IDU and ODU do not
match. The equipment is waiting for the operator to operate the IDU/ODU-ACO switch.
Meaning of indications on the main IDU (classic):
Red LED
Red LED
Yellow LED
Green LED
Green LED
URG
NURG
BZ
IDU
ODU
ON :
ON :
ON :
ON :
ON :
3CC14295AGAA TQ BJA 01
ON :
ON :
ON :
ON :
ON :
271/374
MAN
T-IDU
T-IDU
TX-ODU
TX-ODU
RX-ODU
RX-ODU
IDU
ODU
Note: One green LED IDU / ODU OFF indicates an alarm on the equipment.
With the analog cable interface, the G.826 counters are not correctly evaluated.
--
6.3
Changing IDU
The IDU box can be of two different types. Both kinds are defined in paragraph 7.2.2.2.
Please refer to this paragraph to identify your box.
6.3.1 -- Replacing like for like a Light or classic IDU (1+0 or basic 1+1)
--
Power down the Light IDU / main IDU. Disconnect it from the power source.
--
Disconnect all the cables connected to the unit you are changing (remember to remove the software
key).
--
Change the Light IDU / main IDU after checking that the characteristics match (number of inputs,
impedance, etc). The impedances of the IDU can be reconfigured in any case (see 7.2.2) and
configuration is not needed with IDU which reference ends with the C letter (3CC......C) provided cables
referenced by Alcatel are used.
--
Reconnect all the cables to the unit and the software key.
--
--
Wait for the URG, NURG and ATT LEDs to start flashing simultaneously.
--
Configure the IDU from the ODU by setting the IDU/ODU switch to the ACO/ODU position. Wait about
two minutes for the terminal to be reconfigured. The alarm LEDs should go off and the equipment LEDs
should turn green.
--
Check that there are no alarms in the LUX50 1320CT software application.
--
In the event of an error, particularly if the pushbutton is set to the wrong side, re-enter all of the station
configuration (see section 5, Commissioning).
272/374
3CC14295AGAA TQ BJA 01
Note: In the case of a basic 1+1 configuration, power down the extension IDU.
6.3.2 -- Replacing a Light IDU with a classic IDU (1+0 only) and vice versa
The procedure for changing the equipment is the same as for like for like replacement, but, in some cases, the
ODU configuration may not be taken into account. Connect the 1320CT to the IDU. Run the
Configuration/Quick Config procedure in order to change the NE configuration from 1 + 0 to 1 + 0L or vice
versa.
-- Update the stations installation form (see model in Appendix 2).
6.3.3 -- Replacing like for like a main IDU with MUX protection
--
Force operation using the protection command Forced on Channel #1 for Mux/Demux protection,
and switchover to the multiplexer/demultiplexer on the extension IDUs SCU board.
--
--
Power down the main IDU. Disconnect from the power source.
--
Disconnect all the cables connected to the unit you are changing (remember to remove the software
key from the main IDU). For IDU configured with a MUX protection without Access IDU, only disconnect
the part of the cables connected directly to the IDU.
--
Change the main IDU after checking that the specifications are the same (number of inputs, impedance,
etc).
--
Reconnect all the cables to the unit starting with the lower MAIN/EXT cable (68--pin connector) taking
care not to damage the contacts and also the software key from the removed unit.
--
--
Wait for the URG, NURG and ATT LEDs to start flashing simultaneously.
--
Send the ODUs configuration to the IDU by pushing immediately on the IDU/ODU switch to the
ACO/ODU position (the lower green LED must be lighted).
Warning: An error of handling at this moment, will result in a connection break with a
loss of traffic.
The flashing of the leds is limited to 1 minute. The switch has to be activated as soon as the
led starts flashing otherwise the IDU sends its configuration to the ODUs and breaks the
connection.
--
The alarm leds should turn off and the 2 green leds should light on the main IDU (this stage can take
around one minute according to the ODU type).
--
Check that there are no alarms in the LUX50 1320CT software, otherwise cut off forcing on the receiver
of the spare ODU.
--
In the event of an error, particularly if the pushbutton is set to the wrong side, re-enter all of the station
configuration (see section 5, Commissioning).
Check that the transmit and receive multiplexers are switched to the main channel.
--
Power down the extension IDU and disconnect it from the power source.
--
Disconnect all the cables connected to the unit you are changing.
--
Change the unit after checking that the specifications are all the same (number of inputs, impedance,
etc).
3CC14295AGAA TQ BJA 01
273/374
--
--
--
--
--
274/374
3CC14295AGAA TQ BJA 01
--
6.4
Changing ODU
If you are replacing a ODU UX 23 MHz/1008 MHz with a A9400 UX Flat ODU, make sure
that the new ODU is compatible with the operating frequency.
--
--
--
Change the ODU after checking that the characteristics of the two ODUs are the same.
--
--
--
In the case of a standby ODU, wait two minutes. The reconfiguration takes place automatically.
--
For a main ODU, wait for the URG, NURG and ATT LEDs to start flashing simultaneously. Configure
the ODU from the IDU by pushing the IDU/ODU switch to the IDU position. Wait about two minutes
for the terminal to be reconfigured. The alarm LED should go off and the equipment LEDs should turn
green.
--
Check that there are no alarms in the LUX50 1320CT software application.
--
In the event of an error, particularly if the pushbutton is set to the wrong side, re-enter all the station
configurations (see section 5, Commissioning).
-- If you are replacing an 16 QAM UX ODU or an 13 or 15 GHz ODU with RTPC by a A9400UX flat ODU,
you must systematically upgrade the software feature key.
3CC14295AGAA TQ BJA 01
275/374
276/374
3CC14295AGAA TQ BJA 01
7 -- Changing configurations
Changes to the transmission network may entail upgrading the equipment configurations to satisfy new
requirements. The 9400 UX system is designed to support these changes simply by modifying the software
configuration, or by physically modifying the equipment and its configuration.
Before any change of configuration, disable all remote controls.
For any work on the boards (dismantling/reassembly, change of configuration), the
operator must wear a grounded wrist strap (for example, the 3M Disposable Wrist
Strap, reference 2209).THESE OPERATIONS MUST BE CARRIED OUT ONLY BY
TECHNICIANS, AUTHORIZED BY ALCATEL.
Update the reference documents and the labels in accordance with the new
configuration.
Some of these operations may entail opening the IDU to change the hardware configuration ( 7.6 ). These
changes may lead to:
-- changing the IDU ( 6.3):
replacing like for like a light or classic IDU (1+0 or basic 1+1) ( 6.3.1),
replacing a Light IDU with a classic IDU (1+0 only) or vice versa ( 6.3.2),
replacing like for like a main IDU with multiplexer protection ( 6.7.3),
--
--
S
--
--
changing the bit rate by changing the LAU and LIU tributary boards ( 7.2.5),
--
--
supervision
--
3CC14295AGAA TQ BJA 01
277/374
--
--
--
configuring service channels 3, 4 and 5 in the main IDU without ESC extension ( 7.8.1),
configuring the service channel and network ports of a Light IDU ( 7.9),
upgrading from 1+0 to 1+1 without ESC extension or MUX protection ( 7.11.1),
--
--
--
--
278/374
3CC14295AGAA TQ BJA 01
--
7.1
Changing frequency
A change of frequency within the same sub-band does not entail moving to each station of the link. The change
of frequency on remote station (B) can be applied from local station (A) using the local supervision function, or
from the general supervision terminal.
The frequency of the remote station must always be modified before that of the local
station.
--
Update the information sheet needed to install the station (Appendix 2).
--
--
--
For each channel, modify the transmit and receive frequencies (if authorized) and click on Apply
--
Check that the duplex separation between the transmit and receive frequencies is correct.
--
--
--
For each channel, modify the transmit and receive frequencies (if authorized) and click on Apply.
--
Check that the duplex separation between the transmit and receive frequencies is correct.
--
--
--
Check that there are no alarms in the LUX50 1320CT software application.
Changing frequency in a different sub-band entails changing the ODU (one or two units according to the
configuration).
Changing frequency in another frequency band also entails changing the antennas and, if necessary, the HSB
coupler.
This means that, in both cases, changing the frequency entails going to each station. The configuration is
changed locally in each station by software.
The following procedures must be carried out on each station:
-- Update the information sheet needed to install the station (Appendix 2).
--
--
Adjust the outdoor part according to the new configuration (exchanging ODUs and, if necessary,
antennas and the HSB coupler), referring to section 3, Installation.
--
If there is a change of frequency band, make sure the correct ODU and duplexer are selected.
In all cases, adjust the Tx and Rx frequencies according to the new frequency band.
--
In a 1+1 HSB configuration, check that the transmit and receive frequencies of the two channels are
the same.
--
3CC14295AGAA TQ BJA 01
279/374
--
7.2
Changing tributaries
Update the information sheet needed to install the station (Appendix 2).
--
--
Activate the required tributaries by changing their signal mode from Disabled to Unframed.
--
connection of the cable 75 referenced 3CC07885ADAA for the 4 x 2 Mbits with 1.6 / 5.6 connectors
or referenced 3CC07885AEAA for the 8 x 2 Mbits with 1.6 / 5.6 connectors or 3CC07759ADAA for the
4 x 2 Mbits with BNC connectors or 3CC07759AEAA for the 8 x 2 Mbits with BNC connectors whereas
the IDU is forced in 120 .
--
--
automatic configuration when connecting the cables in 1+0 or in 1+1 provided that the codified Alcatel
cables are used or that the cabling is respected as defined in Appendix 6.1.1.1.
These configuration possibilities are listed in the table in the chapter 7.2.2.2.
7.2.2.2 -- Configuration of the impedances according to the configuration
During the lifetime of a product, various versions of the material manufacturing are made and to ease the
explanation of configuration modifications of these various versions, we use the following acronyms (IDU ,
IDU ,CABLE , CABLE ).
280/374
3CC14295AGAA TQ BJA 01
DEFINITION
IDU
L.A.U boards
References of the
extension IDU
* x = A or B
IDU (Z AUTO appears on the connector panel. See Appendix 6.)
L.A.U boards
References of the
extension IDU
75
120
Reference
Connector
Mbits/s
3CC07885AAxx
1.6/5.6
4X2
3CC07885ABxx
1.6/5.6
8X2
3CC07759AAxx
BNC
4X2
3CC07759ABxx
BNC
8X2
3CC07658AAxx
distribution bar
8X2
CABLE
Reference
Connector
Mbits/s
3CC07885ADxx
1.6/5.6
4X2
3CC07885AExx
1.6/5.6
8X2
3CC07759ADxx
BNC
4X2
3CC07759AExx
BNC
8X2
3CC14295AGAA TQ BJA 01
281/374
GENERAL PRINCIPLE
In 1+0 or 1+1 configuration, the impedance modifications from 120 { 75 are made on the L.A.U. boards.
In 1+1 configuration with the multiplexer protection, the main IDU and the extension IDU are positioned in high
impedance and it is the IDU port that is configured in 75 or 120 .
In 34 Mbits (with only the IDU ), the impedance modifications are made on the 3CC06061AAxx board as
indicated in chapter 7.2.2.4.
In n X 2 Mbits/s with IDU , to modify the impedance from 120 { 75 or to get high impedance (HZ) the straps
have to be positioned on the 3CC06059AAxx or 3CC06058AAxx as indicated in chapter 7.2.2.4.
In n X 2 Mbits/s with IDU , the impedance modifications are made automatically when connecting the cables
in 1+0 or in 1+1 provided that the codified Alcatel cables are used or that the cabling is respected as defined
in Appendix 6.1.1.1. It is only when using the 3CC06059ACxx or 3CC06058ABxx board has to be configured
as indicated in chapter 7.2.2.4.
If the IDU is used, it is strongly recommended to change or to remain in automatic
position and it is only when using the cable that it is mandatory to change in
manual configuration.
7.2.2.3 -- Method
--
Update the information sheet needed to install the station (Appendix 2).
--
Power down the main IDU and, if necessary, the extension IDU. Disconnect them from the power
source.
--
Disconnect the tributary ports and engineering service channels between IDUs.
--
--
Set the strap on the LAU board or boards to the 75 ohms, 120 ohms or protection setting as required.
--
--
Reconnect the connectors of the tributaries and service channels to the IDUs.
--
--
282/374
3CC14295AGAA TQ BJA 01
Tributary positions
2 Mbit/s auxiliary
34 Mbit/s tributary
IN
34 Mbit/s
OUT
Positions of impedance straps and ports on the 34 Mbit/s LAU board, 3CC06061AAxx
34 Mbit/s in 75 ohms
2 Mbit/s in 75 ohms
3CC14295AGAA TQ BJA 01
283/374
T101
Tributary N_ 1/9
TB251
T151
TB252
T201
Tributary N_ 4
TB252
T251
T251
C450
T351
75
T401
111
TB452
Tributary N_ 3/11
1
1
1
TB402
75
T401
3719
201
3719
Tributary N_ 3
Tributary N_ 2
Tributary N_ 2/10
T450
T301
1
1
1
T451
120C400
12075
111
TB452
T450
TB402
TB400
TB352
12075
20
TB302
120C400
T400
TB401
C350TB400
TB451
B350
TB351T
TB301
Tributary N_ 8/16
Tributary N_ 5/13
C300
C450
T451
T400
TB401
TB300
T350
TB450
T300
1
2
1 75
1
1 120
TB451
TB202
TB250
C250
Tributary N_ 4/12
TB450
TB201
1 75
1
1 120
T250
TB251
TB250
C500
Tributary N_ 1
TB201
T250
TB200C250
TB152
TB102
J101
TB150C200
C150
TB151
Tributary N_ 7/15
Tributary N_ 6/14
1
T101
1
1 120
C100
C500
T200
TB10175
J101
TB102
C100
T150
T100
TB100
1
1
1 120
1
2
TB101 75
TB100
T100
P101
P101
3CC06059AAxx
3CC06058AAxx
Strap positions
75 ohms
120 ohms
The 75 ohm and 120 ohm settings are marked on the PCB
284/374
3CC14295AGAA TQ BJA 01
T102
C101
C101
T110
T111
T111
MX108
T115
T115
S101
CR101 CR102
10
ON
1
20
20
19
37
ON
MX109
19
37
10
T116
MX109
T116
S101
CR101 CR102
T112
MX107
T112
MX107
T114
J101
T108
MX108
T109
MX104
J101
MX104
T108
MX106
T107
MX105
T106
T113
T105
T105
MX103
T104
MX102
T103
T101
T102
1
T101
MX101
3CC06059ACxx or 3CC06058ABxx
MX101
--
P101
P101
3CC06059ACxx
3CC06058ABxx
S101
ON
ON
ON
10
10
ON
ON
10
ON
Auto/Z
10
Auto/120
Hard
Std
10
Auto/Z
Auto/120
Hard
Std
Auto/Z
Auto/120
Hard
Std
10
Auto/Z
Auto/120
Hard
Std
10
S101
S101
ON
ON
HZ
75
Soft
Spe
use of cable
HZ
75
Soft
Spe
HZ
75
Soft
Spe
HZ
75
Soft
Spe
3CC14295AGAA TQ BJA 01
285/374
auxiliary 2 Mbit/s tributary port impedence must be set to 75 ohms or 120 ohms.
Note: The impedance of the 34 Mbit/s tributary port must not be modified, it is set to 75 ohms.
1J101
IN
R126
C103
R130R128
R131R127
OUT
20
1
1
20
1
20
34 Mbit/s
R121
R124
J102
R125
R119
DH101
R129
MCL
J102
R132
R122
J103 R133
P102 J103
R123
P101
R110
R113
R114
R120
R104
19
37
19
37
T101
3719
R103
R105
R107 C102 R106
R108
L101
R111
R117
R109
R118
R115
R116
R112
R102
R101
C101
Figure 200 - Position of 2 Mbit/s impedance strap and tributary ports on board 3CC07443AAxx
286/374
3CC14295AGAA TQ BJA 01
TB102
T110
R166
C125
TB127
R183
R186 TB130
C103
T112
T104
37
19
19
R214
C138
1
20
1
20
R216
Tributary N_ 3
P101
C136
C140
37
37
19
19
R220
C134
R218
C128 R172
R194 TB136
R195
R193
L112 TB135
R196
TB132
R182
R189
R185
R181
R191
R187
L109 TB125
L111 TB133
L110 TB129
R192
R188
R184
R190
R151
R150
L104 TB116
R152
C111
R136 TB104
R135 TB103
C110
T111
T103
R148
R147
L103 TB113
R149
R170
R168
C126
C127
TB128
R165C117
C102
R103
R104
R141
R142
L102 TB111
L101 TB109 R145
R143
R146
R133
R101
R102
R117
R118
C109
TB101 R134
T109
TB112
T102
TB131
R167C118 R144
R215C135
TB114
C101
TB134
R119
R120
R169C119
R217C137
TB115
C133
TB105
T113
T105
C144
R224
R203
R202
L114 TB141
R204
R176
C130
TB140
R201
R157
R156
L106 TB119
R158
P102
C142 R222
R198
R199
L113 TB137
R200
T114
T106
C114
R138 TB106
C105
C113
R174
C129
TB138
R197
R153
R154
L105 TB117
R155
R137
C112
C104
R107
R108
R123
R124
R105
R106
R121
R122
R171C120
R219 C139
TB118
TB139
TB110
TB126
R213
TB142
T115
T107
20
20
1
C148
R228
C146
R226
TB148
R180
TB123
R164
R209
R211
L116 TB146
R212
R210
C116
TB108
C132
R163
R162
L108
C108
R206
R207
L115 TB143
R208
C131 R178
TB144
R205
R160
R159
L107 TB121
R161
T116
T108
C115
R140
C107
R113
R114
R139 TB107
C106
TB122
R109
R110
R125
R126
R175C122
R223 C143
R173C121
R221C141
TB120
R111
R112
R127
R128
R177C123
3CC14295AGAA TQ BJA 01
TB145
75 ohms
R225C145
Tributary N_ 8
R129
R130
Tributary N_ 6
R179C124
Tributary N_ 4
TB147
Tributary N_ 2
R227C147
Tributary N_ 16
3719
Tributary N_ 14
R131
R132
Tributary N_ 12
P103
TB124
-R115
R116
Tributary N_ 10
T101
CONFIGURING THE TRIBUTARIES ON THE N X 2 MBIT/S LAU COMBINATION BOARD IN ACCESS IDUS
-- positions of N x 2 Mbit/s tributaries on board 3CC06765AAxx
Tributary N_ 9
Tributary N_ 11
Tributary N_ 13
Tributary N_ 15
Tributary N_ 1
Tributary N_ 5
Tributary N_ 7
120 ohms
The 75 ohms and 120 ohms settings are marked on the PCB
On board 3CC06765AAxx, the impedances of the tributary ports must be set to 75 ohms or 120 ohms.
287/374
Update the information sheet need to install the station (Appendix 2).
--
Power down the IDUs, disconnect them from the power source and disconnect the tributary, service
channel and inter--unit cables.
--
--
Disconnect the plug linking the power supply to the front panel.
--
On the front panel, using a 5 mm flat wrench, remove the spacers securing the LAU boards to be
replaced.
--
Raise and remove the LIU board (held on the lower circuit by two plugs).
--
Remove the LAU board and the corresponding LIU board (linked by ribbon cable).
--
Install the new LAU and LIU boards after checking the impedance configurations.
--
--
Reconnect the tributary, put a label to identify the new impedance type on the front panel,
--
Reconnect the service channel, inter unit and power supply cables.
--
--
Repeat the commissioning operations described in section 5, in particular, make sure the following
parameters are updated:
--
Capacity
Figure 203 - Indoor unit, positions of LAU and LIU boards and port wiring
288/374
3CC14295AGAA TQ BJA 01
--
Update the information sheet needed to install the station (Appendix 2).
--
--
Disconnect the tributary ports and engineering service channel from the IDU.
--
--
--
--
Reconnect the connectors of the tributaries and service channel to the IDU.
--
--
ON
10
S104
ON
S105
10
ON
S106
10
ON
T107
MX162
T106
T108
C139
K104
K105
CR125
CR123
CR122
S108
K103
CR124
K102
MX167
19
S109
C146
C147
MX168
20
1
37
P101
C142
MX164
J107
MX170
C148
37
19
C140
FL106
MX165
ON
C141 C143
C138
20
5
9
1
6
5
9
1
6
P102
MX166 CR119
R121
C149
L110
CR121
CR127
J108
C151
P103
L108
L112
L109
MX171
C150
FL105
MX159 L105L106
C136
C137
C134
C133
R119
R120
C132
C135
ON
S101MX161
T105
S107
10
L107
R117
MX160
ON
S103
10
CR117
CR126
R122
R123
CR116
DS102
C153
FL107
S102
10
Y108
T104
CR118
T103
R118
K101
C144
C145
10
T102
Y107
C152
T101
C131
C130
C127
L111
CR115
C124 CR111
C129 MX156
C128
6 1
--
95
CR120
--
MX163
MX169
--
MX157
The port impedance values of tributaries 1 to 4 can be set to 75 ohms or 120 ohms using switch modules:
-- S105 for channel 1
A101 A102
3CC14295AGAA TQ BJA 01
289/374
Switches 5 to 10 are for choosing the 75 or 120 ohms impedance for the
channel concerned.
-- Switches 2, 3, 4 are for choosing the type of ground in 75 ohms
configuration.
-- The combination of settings of switches 1 on S104 and S105 can be used
to identify the type of engineering practice containing the SCU board: switch
1 of S102 and S103 is not used.
Figure 205 - Locating and using the switches on the switch module
OFF
OFF
ON
ON
HDB3_IN_P
120 ohms
TRANSFO
HDB3_IN_M
OFF
ON
3
OFF
OFF
board electrical ground
OFF
ground isolated from board
OFF
ON
The position of switch 1 should not be altered (reserved for factory use)
In the classic IDU version, choose, from the list of available bit rates, another bit rate offered by the software
feature key--LAU and LIU board combination (for example, change from a 4x2 Mbit/s configuration to an 8x2
Mbit/s configuration).
In the Light IDU versions, you can change from a 2x2 Mbit/s configuration to a 4x2 Mbit/s configuration (or vice
versa).
290/374
3CC14295AGAA TQ BJA 01
This operation can be performed only if the number of tributaries used is less than the number of tributaries
available on the equipment. If this condition is satisfied, you must also have a software feature key that
is compatible with the new bit rate. If not, you must first change the key as described previously in 7.3.
The bit rate of the remote station must always be modified before that of the local station.
--
Update the information sheet needed to install the station (Appendix 2).
--
--
--
--
7.2.5 -- Changing bit rate by changing an LAU and LIU tributary boards
These operations concern only classic IDUs.
7.2.5.1 -- Procedure
The case in which a change of bit rate does not involve changing the LAU and LIU boards is described in 7.2.
The table below summarizes the procedures according to the various changes of configuration.
UPGRADE
1+0 or 1+1
CONFIGURATIONS
MAIN IDU
4 inputs
#
8 inputs
8 inputs
#
16 inputs
n x 2 Mbit/s
#
34 Mbit/s
34 Mbit/s
#
n x 2 Mbit/s
(n 4)
Change boards:
LAU:
3CC06058xxx !3CC06059xxx
LIU:
3CC05818AAxx ! 3CC06026AAxx
3CC06058xxx !3CC06059xxx
LIU:
3CC05818AAxx ! 3CC06026AAxx
Add boards:
LAU:
3CC06059Axxx
3CC06059Axxx
LIU:
LIU:
3CC06119AAxx
3CC06119AAxx
Change boards:
LAU: ! 3CC06061Axxx
LIU: ! 3CC06118AAxx
and main IDU configuration:
34 Mbit/s: 75 ohms
2 Mbit/s tributaries: 75/120 ohms
Change boards:
LAU: ! 3CC06061Axxx
LIU: ! 3CC06118AAxx
and configuration of main and
extension IDUs:
34 Mbit/s: protection
2 Mbit/s tributaries: 75/120 ohms
Change boards:
LAU:
Change boards:
LAU:
3CC06061Axxx ! 3CC06058Axxx
LIU:
3CC06118AAxx ! 3CC05818AAxx
3CC14295AGAA TQ BJA 01
3CC06061Axxx ! 3CC06058Axxx
LIU:
3CC06118AAxx ! 3CC05818AAxx
3CC07443AAxx ! 3CC06765AAxx
291/374
UPGRADE
1+0 or 1+1
CONFIGURATIONS
MAIN IDU
34 Mbit/s
#
n x 2 Mbit/s
(4 < n 8)
34 Mbit/s
#
n x 2 Mbit/s
(n > 8)
ACCESS IDU
Change boards:
LAU:
Change boards:
LAU:
3CC06061Axxx ! 3CC06059Axxx
LIU:
3CC06118AAxx ! 3CC06026AAxx
3CC06061Axxx ! 3CC06059Axxx
LIU:
3CC06118AAxx ! 3CC06026AAxx
Change boards:
LAU:
3CC06061Axxx
! 2 x 3CC06059Axxx
3CC06061Axxx
! 2 x 3CC06059Axxx
3CC07443AAxx ! 3CC06765AAxx
LIU:
LIU:
3CC06118AAxx
! 3CC06026AAxx + 3CC06119AAxx
292/374
3CC06118AAxx
! 3CC06026AAxx + 3CC06119AAxx
3CC14295AGAA TQ BJA 01
7.2.5.2 -- Method
--
Update the information sheet need to install the station (Appendix 2).
--
If the new configuration requires a change of key, change it first (see 7.3).
--
Power down the IDUs, disconnect them from the power source and disconnect the tributary, service
channel and inter-unit cables.
--
--
Disconnect the plug linking the power supply to the front panel.
--
On the front panel, using a 5 mm flat wrench, remove the spacers securing the LAU boards to be
replaced.
--
Raise and remove the LIU board (held on the lower circuit by two plugs).
--
Remove the LAU board (and for the 34 Mbit/s tributary, disconnect the two subclick plugs).
--
Remove the LAU board and the corresponding LIU board (linked by ribbon cable).
--
For changing from 16 x 2 Mbit/s to 34 Mbit/s, similarly remove the second LAU/LIU board level.
--
Install the new LAU and LIU boards after checking the impedance configurations.
For the 34 Mbit/s version, fit the small daughter board supporting the 1.6/5.6 connectors
(3CC07830AAxx), in place of the top I/O connector (9/16) or ACCESS connector (9/16), fit the daughter
board at the back of the connector panel and secure it by screwing the spacers to the outside of the
connector panel.
--
For the 34 Mbit/s version, remember to connect the two subclick plugs to the LAU board.
--
--
Reconnect the tributary, service channel, inter unit and power supply cables.
--
--
Repeat the commissioning operations described in section 5, in particular, make sure the following
parameters are updated:
IDU Main Type
Capacity
R121
T102
LAU/LIU link
cable
T103
R106
R108
R109
R110
R103
J103
P101
1 R117
2
R118 R125
J105 R130
C105
3719
J104
R104
R105
IN
OUT
T104
R134
R133R135
34 Mbit/s
201
R123
R115
1
2
R124
R126
R127
R128
R129
R119
R120
R116
R122
J102
R111
R112
R113
PSU board
position
R107
R114
C103
R131
R132
--
Power supply
connection board
Figure 207 - Indoor unit, positions of LAU and LIU boards and port wiring
3CC14295AGAA TQ BJA 01
293/374
--
7.3
Connect the CT to the IDU and make sure that the Equipment tab is selected (this is the default).
--
Remove the software feature key from the main IDU and check that the alarm Replaceable Unit
Missing appears on IDU/MAIN/SKU.
--
--
Wait for the software feature key alarm to disappear. The alarm will not disappear if the characteristics
of the key are incompatible with the configuration.
--
7.4
Update the information sheet needed to install the station (Appendix 2).
--
With the CT connected to the NE, select the Configuration/Quick Configuration menu.
--
Navigate through the quick configuration steps and update the IP address and OSPF parameters.
Proceed through the end the Quick Configuration and click Finish.
--
--
Wait (about two minutes) for the NE to reset its management processor in order to apply the new IP
address to the NE.
--
--
294/374
3CC14295AGAA TQ BJA 01
--
7.5
If not already done, install the 1320CT Craft Terminal software on the PC to be used as LUX50 Craft
Terminal, as described in section 4.1.
Replace the LUX12 main IDU with a LUX50 main IDU, following the procedure described in 6.2. At
the end of the operation, the LUX12 configuration coming from ODU is automatically converted to
LUX50 format, and applied to both IDU and ODU.
--
Connect the LUX50 1320CT to the IDUs F interface using F interface adapter cable.
--
--
Install the new memories (including LUX50 flash memory) as shown in figure 204, 7.14.
--
Close the main IDU cover, reversing the order of operations on opening.
--
Reconnect all the cables to the unit and the software key.
--
--
Wait for the URG, NURG and ATT LEDs to start flashing simultaneously.
--
Configure the IDU from the IDU by setting the IDU/ODU switch to the IDU position. Wait about two
minutes for the terminal to be reconfigured. The alarm LEDs should go off and the equipment LEDs
should turn green. At the end of the operation, the LUX12 configuration coming from IDU is
automatically converted to LUX50 format, and applied to both IDU and ODU.
--
--
Connect the LUX50 1320CT to the IDUs F interface using F interface adapter cable.
--
3CC14295AGAA TQ BJA 01
295/374
Connect the LUX12 Craft Terminal to the LUX12 IDU to be upgraded to LUX50.
--
Using Software downloading application (refer to 4.6 in LUX12/LUX40 User Manual), upgrade the
IDU 360 software to LUX50. The LUX50 IDU 360 software file compatible with LUX12 software
download application is available at the following location on LUX50 CD--ROM Ref 3CC14311AxAA:
<CD--ROM Drive>:\V_N50\3CC07767.bin
--
At the end of the operation, the LUX12 configuration is automatically converted to LUX50 format, and
applied to both IDU and ODU.
--
Connect the LUX50 1320CT to the IDUs F interface using F interface adapter cable.
--
--
--
Connect the LUX40 Craft Terminal to the LUX40 IDU to be upgraded to LUX50.
--
Using Software downloading application (refer to 4.6 in LUX12/LUX40 User Manual), upgrade the
IDU 360 software to LUX50. The LUX50 IDU 360 software file compatible with LUX40 software
download application is available at the following location on LUX50 CD--ROM Ref 3CC14311AxAA:
--
At the end of the operation, the LUX40 configuration is automatically converted to LUX50 format, and
applied to both IDU and ODU.
--
Connect the LUX50 1320CT to the IDUs F interface using F interface adapter cable.
--
<CD--ROM Drive>:\V_N50\3CC07767.bin
296/374
3CC14295AGAA TQ BJA 01
--
7.6
Opening an IDU
A classic IDU is opened as described in the photos in Figure 208 and the procedure below.
The procedure for opening a Light IDU is the same, except the step shown in photo , since this unit does not
have a Display panel.
-- Isolate the power supply and disconnect all the cables to the IDU.
--
Undo the side screws on the unit (screws securing the fixing brackets (Photo ) and the metal plates
concealing the fixing brackets mounting position on the operation panel).
--
Using a 5 mm flat wrench, undo the connector fixing nuts on the operation panel of the IDU
(Photo ).
Slide the cover away from the connector panel towards the operation panel using the fixing brackets
as a lever to disengage the cover from the connector panel (Photos and ).
--
3CC14295AGAA TQ BJA 01
297/374
(Classic)
Main IDU
CONFIGURATION
1+ 0
All configurations
ITEM
1 or 1
basic 1+1
Extension IDU
Light MCU
PSU
MCU
PSU
PSU
PSU
5
6
7
Access IDU
298/374
PSU
BOARDS
10
3CC14295AGAA TQ BJA 01
DRAM memory
Flash memory
1
Connector panel
Light IDU
Flash memory
Fans
1
7
5
4
6
Connector panel
10
Connector panel
Access IDU
Fans
1
7
6
5
4
8
9
Connector panel
Extension IDU
3CC14295AGAA TQ BJA 01
299/374
--
7.7
Open the CT and select the menu Configuration/System Settings and click on the Overhead tab.
To cancel use of the telephone on the IDU, check the Disabled option and click Apply.
To enable use of the telephone on the IDU, make sure that the Enabled button is checked. If not,
click it to activate it.
--
--
SETTING
3CC06088AAAN
CHARACTERISTIC
S504 (S104*),
S505 (S105*)
ESC 2 level
audio input
-13 dBm
0 dBm
--13 dBm
0 dBm
S506 (S106*),
S507 (S107*)
ESC 2 level
audio output
0 dBm
+4 dBm
0 dBm
+4 dBm
300/374
3CC14295AGAA TQ BJA 01
--
7.8
The 9400 UX can have up to five ESCs (except in a 2 x 2 Mbit/s configuration in which only three are possible);
for more details, refer to 2.3. Only ESC1 (NMS 1 and NMS 2 connectors) cannot be configured manually.
7.8.1 -- Configuring ESC 3, 4 and 5 in the main IDU without ESC extension
--
Update the information form needed to install the station (Appendix 2).
ESC3, ESC4 and ESC5 can be configured on the main IDU, by switches (see Figures 210 and 211) located
on the digital MCU--NUM board (3CC06088AAxx, for a digital IDU/ODU link), or on the analogue MCU board
(3CC05714AAxx for an analogue IDU/ODU link), in accordance with the following table:
SETTING
3CC06088AAAX
SWITCH
SETTING
3CC06088AAAN
CHARACTERISTIC
S510 (S110*)
ESC 3 port
Clock inversion
S511 to S515
(S111* to S115*)
ESC 3 port
Format
S508 (S108*)
ESC 4 port
Inversion
No inversion Inversion
S509 (S109*)
ESC 5 port
Clock inversion
Inversion
No inversion Inversion
No inversion
V11
No inversion
Inversion
V28
No inversion Inversion
V11
V28
--
Update the information sheet needed to install the station (Appendix 2).
--
Power down the main IDU and disconnect it from the power source.
--
--
Set switches S511 (S111*) to S515 (S115*) on the MCU board to the required position (see 7.7.2).
--
Set switch S510 (S110*) according to the required clock polarity (see 7.7.2).
--
--
Reconnect the main IDU to the power source and power up again.
--
3CC14295AGAA TQ BJA 01
301/374
P101
MX104
MX119
L101
MX114
SW108
MX103
MX105
SW102SW103
SW101
1
6
1
6
CR103
CR102
CR101
Y103
MX118
MX122
A1
B1
1
1
1
1
1
1
6
1
6
L101
MX117
C115
C120 MX112
C119
R105
R107
R106
R108
MX108
J101
MX109
CR107
C102
SW105
C113
MX110
C118
R103
R104
MX115
C123MX116
MX121
C131
MX126
S111
R129
MX123
MX130
MX136
MX129
MX128
MX135
MX144
MX149
SW118
S103
C179
MX177
1
14
1
SW109
K102
SW124
MX164
MX154
SW119 CR123
SW120
MX161
P104
MX176
CR122
MX175
13
25
50
CR124
C124
C125
R111
C126CR110 R113 R114
R115
R109
SW110
R110
CR113
CR112
SW112
T102 T1041
MX120 Q102C128 C129SW111
CR114
CR111
T101 T103
T108
T105 T1071
T106
S104S105
MX148
LS101
C133
CR115
S106 S107 SW114
SW115
CR116
S108
MX127
MX134
C141
Y105
Y106
P101
SW109
MX105
SW102SW103
SW101
MX103
SW108
MX114
S103
J106
CR120
C159
MX150
MX174
FL110SW133
J113
CR142
SW134
1
2
R133
CR133
MX168
MX167
C186
R138
CR136
C185 R140
FL109 Q106
Q105
MX158
Y107
CR102
CR101
CR103
MX104
MX112
MX119
MX123
MX142
MX160
MX173
1
1
1
1
A1
B1
J101
Y103
MX118
MX122
C124
R113 R114R115
SW110 CR113
CR112
SW112
Q102C128 C129SW111
CR111
CR114
MX117
C120
C119
R105
R107
R106
R108
C115
MX108
MX101 MX102
MX109
CR107
C102
Q101 CR104
SW105
C113
MX110
C118
R103
R104
MX115
C123MX116
MX121
MX120
1
1
C125
R111
C126CR110
R109
R110
T102 T1041
T103
C131
MX126
MX130
MX136
CR124
MX154
S108
MX172
CR106
S107
P103
P108
CR143
CR144
J115
T101
T108
T105 T1071
T106
S104 S105
MX135
MX129
MX128
C133
CR115
S106 S107 SW114
SW115
CR116
S108
MX127
LS101
MX144
MX149
SW118
C179
SW119
CR123
SW120
MX161
MX164
SW124
K102
C109C103
C130
CR106
MX177
1
6
1
6
CR108 L102
J108
C141
MX134
MX148
CR122
MX176
5
9
5
9
CR125
Y105
Y106
S111
R129
MX175
P104
1
14
1
2
CR130
CR120
C159
MX150
MX158
Y107
FL110SW133
R133
CR133
MX168
MX167
C186
R138
CR136
C185 R140
FL109
Q105
Q106
MX174
CR142
SW134
1
2
13
25
50
2
3
1
C110
CR105
C155
C171
R125
C160
C172
R126
C151
SW132
C134 C132
C139 SW113
C140
J106
MX173
J113
SW121
SW123SW122
I/O
connector
on
connector
panel
MX160
MX172
P108
S115
C110
C101
C122
C108
C127
R102
SW104
C107
R143
R139
3CC14295AGAA TQ BJA 01
302/374
R112
C114
S114
J115
S105 S106
S104
2
3
1
CR125
C121
C169
R123
C157
C170
C154
R124
R134C176
C180R130
C188
R135
R142 C181C177
R136R131
C182
R137
R132C178
S110
C168
R122
C175
S109
R121
C109C103
C151
C143
C191
C108
C127
CR108 L102
J108
C116
R101
C117
S112
S113
CR143
CR144
C167
S111
SW115
R146
R147
R148
S110
MX142
P103
1
6
1
6
S109
SW121
SW123SW122
S110
R139
C130
C101
C122
C171
R102
CR105
C155
R125
C160
C172
R126
CR130
C154
S515
SW132
R112
C134 C132
C139 SW113
C140
C114
S109
R121
S513
5
9
5
9
S511
R143
S514
R148
S507
S505 S506
S504
SW104
C107
C121
C169
R123
C157
C170
R134C176
C180R130
C188
R135
R142 C181 C177
R136R131
C182
R137
R132C178
C168
R122
C175
C167
C143
C191
R124
C116
R101
C117
S512
SW517
R146
R147
S510
S508
S509
Figure 210 - Locations of switches on the MCU board with digital IDU/ODU link
POSITIONS OF SWITCHES ON THE MCU BOARD (ANALOGUE): 3CC05714AAxx
Figure 211 - Locations of switches on the MCU board with analogue IDU/ODU link
service channels 3, 4 and 5 can be configured in the extension IDU, on the SCU board and the
daughter boards that it supports.
ESC3 position
ESC4 position
Figure 212 - Positions of service channels 3 and 4 in the ESC extension unit
ESC 3 and ESC 4 can be customized via daughter boards ESC 1 to ESC 5 described below. These boards
are installed on the SCU board in the extension unit.
3CC14295AGAA TQ BJA 01
303/374
SETTING
3CC05710AAAA
SETTING
3CC05710AAAB
SWITCH
CHARACTERISTIC
S201
Synchronization
(not active on this
equipment)
Channel 2 bit
(special)
Channel 2 byte
(Normal)
Channel 2 bit
(special)
Channel 2 byte
(Normal)
S202
Synchronization
Channel 1 bit
(special)
Channel 1 byte
(Normal)
Channel 1 bit
(special)
Channel 1 byte
(Normal)
304/374
3CC14295AGAA TQ BJA 01
SETTING
3CC05711AAAB
SWITCH
CHARACTERISTIC
S501
Output level
+4 dBm
0 dBm
+4 dBm
0 dBm
S502
disabled
Enabled
disabled
Enabled
S503
Input level
0 dBm
-13 dBm
0 dBm
-13 dBm
ESC type
Point-tomultipoint
Point-topoint
Point--to-multipoint
Point--to-point
S504
3CC14295AGAA TQ BJA 01
305/374
CHARACTERISTIC
S206
Transmitted clock
inversion
No
inversion
(*)
No
inversion
(*)
S207
306/374
V11
V28
SETTING
3CC05712AAAB
V11
V28
Inversion
(*)
No
inversion
(*)
Inversion
(*)
Inversion
(*)
No
inversion
(*)
Inversion
(*)
3CC14295AGAA TQ BJA 01
(*)
no inversion:
Data
Clock
bit n
bit n+1
D
2D
inversion:
Data
Clock
bit n
bit n+1
2D
Figure 216 - Clock and Data signals onboard 3CC05712AAxx
CAUTION:
The recommended position is the clock inversion for V11 and no inversion for V28:
S inversion of S206 in V11, 64 Kbits and no inversion of S207.
S inversion of S207 in V28, 64 Kbits and no inversion of S206.
3CC14295AGAA TQ BJA 01
307/374
two engineering service channels (4.8 kbit/s maximum), the first point-to-point (PP1A) or
point-to-multipoint (PM1A, PM1B), the second point-to-point (PP2A).
308/374
3CC14295AGAA TQ BJA 01
Switch positions
SETTING
3CC05713AAAA
SETTING
3CC05713AAAB
SWITCH
CHARACTERISTIC
S101
Link type
Point-tomultipoint
Point-to-point
Point-tomultipoint
Point-to-point
S102
1x
(9600 bit/s
max.)
2x
(4800 bit/s
max.)
1x
(9600 bit/s
max.)
2x
(4800 bit/s
max.
3CC14295AGAA TQ BJA 01
309/374
two ESC (4.8 kbit/s maximum), the first point-to-point (PP1A) or point-to-multipoint (PM1A, PM1B), the
second point-to-point (PP2A).
Switch positions
SETTING
3CC06482AAAA
SETTING
3CC06482AAAB
SWITCH
CHARACTERISTIC
S101
Link type
Point-tomultipoint
Point-topoint
Point-tomultipoint
Point-to-point
S102
1x
(9600 bit/s
max.)
2x
(4800 bit/s
max.)
1x
(9600 bit/s
max.)
2x
(4800 bit/s
max.
310/374
3CC14295AGAA TQ BJA 01
SETTING
3CC07794AAAH or
3CC07797AAAH
SWITCH
CHARACTERISTIC
S502 to S505
(S102* to S105*)
and S507 to
S510
(S107* to S110*)
ESC 5 format
V11
V28
V11
V28
S511 (S111*)
Inversion
No
inversion
Inversion
No
inversion
S508
S509
S505
S507
S504
S503
S502
S511
Figure 219 - Switch positions on the SCU board wiith digital IDU/ODU link
3CC14295AGAA TQ BJA 01
311/374
S110
S108
S109
S105
S107
S103
S104
S102
S111
Figure 220 - Switch positions on the SCU board wiith analog IDU/ODU link
7.8.2.3 -- Method
-- Update the information sheet needed to install the station (Appendix 2).
--
Power down the extension IDU and disconnect it from the power source.
--
--
If the change entails changing the ESC 3 and/or ESC 4 daughter board, change as necessary.
--
--
Configure the replaced board or modify the configuration of the existing board (see 7.8.2).
Configure ESC 5:
--
Set switches S502 (S102*) to S505 (S105*) and S507 (S107*) to S510 (S110*) of the SCU board to the
V11 or V28 setting according to the required configuration. Set switch S511 (S111*) according to the
required clock polarity (see 7.8.2).
Close the unit.
--
Reconnect the extension IDU to the power source and power up again.
--
If a change has been made to the ESC 3 and/or ESC 4 daughter boards, connect the CT and run the
Configuration/Quick Config procedure. (see 4.8.5).
--
In Quick Config Step 1, make sure that the appropriate values are selected for ESC3 and ESC4.
--
Run Quick Config until the end in order to apply these new values to the NE.
--
If adding an ESC unit, the positions of ESC 3 and 4 may be fitted with daughter boards.
If the station has back-to-back terminals, transmission of the ESCs from one terminal
to the other is performed in baseband and the extension units of each of the terminals
must be fitted with daughter boards.
--
Update the information sheet needed to install the station (Appendix 2).
--
--
Open the extension IDU to be added and check the configuration of the engineering service channels
(ESCs 3 and 4 daughter boards, SCU boards for ESC 5). If the configuration needs to be changed:
312/374
3CC14295AGAA TQ BJA 01
--
Install the unit and connect it to the main IDU (see 3.6).
--
Connect the extension IDU to the power source and power up again.
--
Connect the CT and run the Configuration/Quick Config procedure. (see 4.8.5).
--
If the previous NE configuration was 1 + 0, change it to 1 + 0EXT. In all other cases leave it unchanged.
--
--
Run Quick Config until the end in order to apply these new values to the NE.
--
3CC14295AGAA TQ BJA 01
313/374
--
7.9
--
OFF
ON
ON
Clock state
Switch state
Forward
OFF
Reversed
ON
V.28 configuration
Figure 221 - Selecting the V.11 or V.28 configuration and clock direction
7.9.2 -- Methodology
V.11 { V.28 conversion of ESC3, NMS1 and NMS2
--
Update the information sheet needed to install the station (Appendix 2).
--
Power down the IDU and disconnect it from the power source.
--
--
Set switch modules S101, S106 and S107 on the MCU board, with switches 1 to 8 set as described
in 7.9.1.
--
To alter the polarity of the clock, adjust switch 10 on the same switch modules (see 7.9.1)
--
--
--
314/374
3CC14295AGAA TQ BJA 01
7.10
--
1
6
1
6
C109
C103
5
9
5
9
2
3
1
C110 C104
C105
C111
MX106
CR106
L101
CR108
L102
P102
CR109
SW109
P101
SW108
SW102
SW101 SW103
MX104 MX103 MX105
MX112
MX114
MX113
SW107 S102
C112
C106
S101
Y102
DS101
Y101
SW106
MX111
J103
J104
FL101 MX124
FL102
FL105
72
72
FL103
FL104
TB102TB101
MX107
MX125
C165
L103
MX143
C144
MX119
S103
L110
R127
R128
C164
C138
C184 J109
C183
CR139
MX171
R144
R145
J112C752
L113
J117
C136
MX170
C190
C193
L112
C137
C142
C148
DS102
MX139
R141 MX163
C189
C130
C135
J110
J116
CR129
CR135
CR138
CR132
MH101
CR134
CR128
CR137
CR131
SW110
CR113
CR112
SW112
SW111
CR111
CR114
MX123
CR115
CR116
J115
MX130
MX129
MX136
SW118
J118
SW119
CR123
SW120
CR124
C151
MX132 Y104
J105 MX131
L104
CR117
MX133
L105
SW116
MX138
CR118 MX137
CR119 R117 R116
R118
L106
FL106
SW117
MX145C153
C152 J107
MX146
FL107
L107
MX147 C156
Q103
C161
R119
C158
MX151
C162
K101 CR121
C166 R120 C163
MX153 L109
Q104
L108
C753 C173
FL108
C174 CR126 L111
MX162
CR127 MX159
K105
A102
CR122
K104
MX155MX156 MX157
MX154
C179
MX164
MX165 MX166
K103
DS103
A101
J108
CR125
C192
CR140
FL111
MX161
SW132
SW127
SW131
SW129
SW124
SW125
SW126
SW128
SW130
K102
TS1 : SW128
TS2 : SW129
TS4 : SW130
TS3 : SW131
L114
P106
1
6
1
6
TS1 : SW532
TS2 : SW533
TS4 : SW534
TS3 : SW535
5
9
5
9
TS7 : SW125
TS6 : SW126
TS5 : SW127
P105
1
6
1
6
TS7 : SW529
TS6 : SW530
TS5 : SW531
5
9
5
9
TS8 : SW124
1
14
21
TS8 : SW528
MX176 MX177
P104
J102
Unactivated
RS input
3CC14295AGAA TQ BJA 01
Swap position
RS input
Prewired swap
RS input
Normally closed
Alarm condition
RS input
315/374
7.10.1.2 -- Method
Changing the configuration of remote indication loops 1 to 8 entails moving soldered links on the MCU board.
--
Update the information sheet needed to install the station (Appendix 2).
--
Power down the main IDU and disconnect it from the power source.
--
--
--
--
--
--
--
Declare the names of the new RIs with the CT by selecting the External Points tab. For each input
port, a dedicated alarm profile can be used.
--
Check the operation of the remote indication loops by verifying that their color changes from green to
yellow, blue, brown, or red (depending on the alarm profile) when the corresponding loop is active.
316/374
3CC14295AGAA TQ BJA 01
R102
J101 A1 R101
R102
R103
R104
R105
MX153
S108 S109
K103
19
37
19
37
P101
1
20
1
20
C128
ON
C139C141
C143
K104 K105 C138
C140C142
C146 MX168
C147
C148
CR125
CR123
CR122
MX167K102
ON
5
1
9
6
5
1
9P102
6
C121L104
CR114
FL104
R118
K101 R117
L106
L105
MX159
C135C136
FL106 C137
L108
CR119
MX165
MX166
L112
L109
J107R121
L110
CR121
CR127
MX171
MX170
C149
J108
C150
MX164
L111
ON
T108
95
ON
T107
CR120
ON
T106
MX162
ON
T105
CR124
ON
MX161
MX169 MX163
C123
C124
CR111
C125
CR112
C126 C127 Y107
MX156
C129
Y108
C131T101 T102 T103 T104 CR116 CR117
C130S102 S103 S104 S105 S106 S107
CR115
S101
10
1 10
1 10
1 10
1 10
1 10
1 10
1
MX137MX138
FL101
J106
FL103
DS101
L102
CR107
MX144
C119
MX145
L103
CR108
C118
MX155
C144
C132
C145 CR118
C152
FL107
CR126
MX160
R122
R123
C133
C134
L107
R119
R120
FL105MX158MX146
C107
MX136
L101
MX154
C122
MX151
MX157
MX152MX143
C110
C102
P103
R112
J104J103
MX131
C106
C104
C105
C103
C113
C112
Y103
C116
C111
C109C117 Y104
CR109
CR110
Y106
CR113 Y105
CR106
CR105
MX140
61
MX125
MX120
MX114
MX135
MX134
MX141
MX133
MX150
MX148
MX149
MX139
MX132
MX147
R108
FL102
C108
J105
C114
MX142
C115
C120
R106
MX129
R110
72
Y102
MX130
SW103 CR102
MX128
MX123
MX122
MX119
CR103
MX127
CR104
MX126
R104 R105
J102
72
MX124
MX121
MX115
C101
Y101
B1
MX102
MX103
MX104
R106MX101
MX107
MX105 MX106
R109 R111
R107R108
R110
MX108
MX109
MX110
MX111
MX118
R113
R115 R116
MX112 MX113
R112
R114
MX116 MX117
SW102
SW101
CR101
RI1 : R115
RI2 : R102
RI3 : R110
C151
C153
DS102
A101
A102
R115
RI4 : R105
RI5 : R108
RI6 : R112
RI7 : R104
RI8 : R106
Loop type
Normally open
Unactivated
RS input
RS input
RS input
RS input
Normally closed
3CC14295AGAA TQ BJA 01
Alarm condition
317/374
7.10.2.2 -- Method
To change the configuration of the remote indication loops 1 to 8 to normally closed loops you must fit 0 ohm
SMC resistors to the MCU board.
--
Update the information sheet needed to install the station (Appendix 2).
--
Power down the IDU and disconnect it from the power source.
--
Disconnect all tributary, service channel and inter--unit cables (See 3.7.1).
--
--
Solder zero value SMC resistors to the MCU board, in the positions shown in Figure 223.
--
--
Connect the new remote indication loops directly to the ESC3 / ALARM I/O connector or via a cross
connect panel.
--
--
Declare the names of the new remote indication loops with the CT by selecting the External Points
tab. For each input port, a dedicated alarm profile can be used.
--
Check the operation of the remote indication loops by verifying that their color changes from green to
yellow, blue, brown, or red (depending on the alarm profile) when the corresponding loop is active.
7.11
--
7.11.1 - Changing from 1+0 to 1+1 without ESC extension or MUX protection
Not applicable in the Light IDU versions.
--
Update the information sheet needed to install the station (Appendix 2).
--
--
Connect the tributary, engineering service channel and inter-IDU cables (See 3.7.1).
--
--
If necessary, change the software key on the main IDU (1+1 max).
--
Install the new ODU configuration, referring to section 3: ODU, HSB coupler, antenna, extension IDU
link cable.
--
318/374
3CC14295AGAA TQ BJA 01
--
Update the information sheet needed to install the station (Appendix 2).
--
--
If necessary, change the software key on the main IDU (1+1 max).
--
Install the extension IDU (check the ESC configuration, see 7.8.2).
--
Connect the tributary, service channel and inter-unit cables (see 3.7.1).
--
--
Install the new ODU configuration referring to section 3: ODU, HSB coupler, antenna, link cable with
extension IDU.
--
7.11.3 - Upgrading from 1+0 to 1+1 with multiplexer protection and access IDU
Not applicable in the Light IDU versions.
The IDU box can be of two different types. Both kinds are defined in 7.2.2.2 . Please refer
to this paragraph to identify your boxes;
The use of the access IDU requests to have specific LAU and LIU selection straps. These
straps depend on the kind of IDU available. (see 7.2.2.4 for more details)
--
Update the information sheet needed to install the station (Appendix 2).
--
If necessary, change the software key on the main IDU (1+1 max).
--
Power down the main IDU. Disconnect it from the power source.
--
--
--
If there is one, open the extension IDU, remove the customizing boards and install them in the new
extension IDU.
--
Check that the number of physical ports on the main and extension IDUs are the same.
--
On the LAU boards of the extension IDU, set the tributary impedance selection straps to Protection
with port for type n IDU or are set to Manual forcing in protection mode with port for type o IDU.
--
On the LAU boards of the main IDU, set the tributary impedance selection straps to Protection with
port for type n IDU or are set to Manual forcing in protection mode with port for type o IDU.
--
On the LAU combination board of the access IDU, check the positions of the impedance selection
straps.
--
--
--
Install the new ODU configuration, referring to section 3: ODU, HSB coupler, antenna, extension IDU
link cable.
--
Reconnect the tributary, service channel and inter--unit cables (see 3.7.2).
--
3CC14295AGAA TQ BJA 01
319/374
This change of configuration entails replacing the extension IDU with a version supporting multiplexer protection
and the addition of an access IDU.
-- Update the information sheet needed to install the station (Appendix 2).
--
Power down the main and extension IDUs. Disconnect them from the power source.
--
--
--
On the LAU boards of the extension IDU, set the tributary impedance selection straps to Protection
with port for type n IDU or are set to Manual forcing in protection mode with port for type o IDU.
--
On the LAU boards of the main IDU, set the tributary impedance selection straps to Protection with
port for type n IDU or are set to Manual forcing in protection mode with port for type o IDU.
--
--
Check that the number of physical ports on the main and extension IDUs are the same.
--
--
Check, on the LAU combination board of the access IDU, the positions of the impedance selection
straps.
--
--
--
Reconnect all tributary, service channel and inter-unit cables (see 3.7.2).
--
--
Install the new ODU configuration, referring to section 3: ODU, HSB coupler, antenna, extension IDU
link cable.
--
320/374
3CC14295AGAA TQ BJA 01
7.11.5 - Upgrading from 1+0 to 1+1 with multiplexer protection without access IDU
This procedure is only available if the IDU type is (see 7.2.2.2).
If not type , please use another IDU of the correct type or upgrade it to type .
--
Update the information sheet needed to install the station (Appendix 2).
--
If necessary, change the software key on the main IDU (1+1 max).
--
Power down the main IDU. Disconnect it from the power source.
--
--
--
--
If there is one, open the ESC extension IDU, remove the customizing boards and install them in the
new extension IDU.
--
Check that the number of physical ports on the main and extension IDUs are the same.
--
On the LAU boards of the extension IDU, set the straps according to 7.2.2.2.
--
On the LAU boards of the main IDU, set the straps according to 7.2.2.2.
--
--
--
--
Install the new ODU configuration, referring to section 3: ODU, HSB coupler, antenna, extension IDU
link cable.
--
Reconnect the tributary, service channel and inter--unit cables (see 3.7.2).
--
3CC14295AGAA TQ BJA 01
321/374
This change of configuration entails replacing the extension IDU with a version supporting multiplexer
protection.
-- Update the information sheet needed to install the station (Appendix 2).
--
Power down the main and extension IDUs. Disconnect them from the power source.
--
--
--
Check that the number of physical ports on the main and extension IDUs are the same.
--
--
On the LAU boards of the extension IDU, set the straps according to 7.2.2.2.
--
On the LAU boards of the main IDU, set the straps according to 7.2.2.2.
--
--
--
--
Reconnect all tributary, service channel and inter-unit cables (see 3.7.2).
--
--
Install the new ODU configuration, referring to section 3: ODU, HSB coupler, antenna, extension IDU
link cable.
--
322/374
3CC14295AGAA TQ BJA 01
7.12
--
Update the information sheet need to install the station (Appendix 2).
--
Modify the output power from the CT using the Radio tab and then the RTPC tab.
--
3 dB
6 dB
10 dB
13 GHz to 18 GHz
3CC08543AAxx
3CC08543ABxx
3CC08543ACxx
--
--
To dismantle: undo the two ends of coaxial link W06 between the filter and the RF amplifier (use an
8 mm torque wrench).
--
To reassemble: screw the attenuator onto the RF amplifier plug and the coaxial coupling onto the
filter plug.
Replace the coaxial link between the filter and the RF amplifier.
Tighten the attenuator, coaxial coupling and the two ends of the coaxial link using the 8 mm torque
wrench.
13 GHz with flexible semi--rigid coaxial cable:
--
3CC14295AGAA TQ BJA 01
323/374
--
--
To dismantle, undo the plug at the filter end of link W06 between the filter and the RF amplifier (TX
output) using an 8 mm torque wrench.
--
To reassemble, screw the attenuator onto the filter plug. Tighten with an 8 mm torque wrench.
--
Replace coaxial link W06 between the filter and the RF amplifier (tighten with an 8 mm torque
wrench).
Replace the top board if applicable (depending on version).
S
--
With a small screwdriver, remove the units ring seal from its groove.
S
--
--
Depending on version, if there is a top board present, check for presence of the CHO--TERM foam pads
on the bottom of the cover.
--
Replace the cover and check the positioning of the front panel polarizer.
--
Tighten the four M4 screws with their nuts using the torque wrench with a socket cap tip to a torque
of 1Nm + 0.2/0.
--
Affix to the unit (on the handle side), the label supplied with the kit, marking on it the internal attenuators
value.
POSITIONING THE ATTENUATOR IN THE ODU
Attenuator
Attenuator
W06
RF
Filter
Filt.
13 GHz
Position of coaxial coupling.
To be fitted in 13 GHz ODU with
semi-- rigid coaxial cable.
324/374
15 and 18 GHz
RF
amplifier
W06
3CC14295AGAA TQ BJA 01
7.13
--
Update the information sheet needed to install the station (Appendix 2).
Dismantling
-- 1) Place the coupler on the table, with the microwave nose (which mates with that of the antenna)
uppermost, and undo the four M6 screws using an M5 Allen key, then remove the nose; you can now
see the waveguide to be replaced.
-- 2) On the side nose corresponding to the standby ODU and marked COUPLED ACCESS on the
casting, insert the 2.5 mm Allen key (M3 screw) and undo the four screws securing the flexible
waveguide.
-- 3) Using a 5 mm Allen key (M6 screw), undo the four screws securing the side-mounted COUPLED
ACCESS nose and remove the nose.
-- 4) Using a 16/17 mm box wrench and an 8 mm Allen key, dismantle: the four M10 socket cap screws
+ four nuts + eight flat washers + four crinkle washers, holding the two shells of the HSB coupler
together.
-- 5) Open the HSB casing and, with a 2.5 mm Allen key, remove the straight waveguide on the antenna
side to replace it with the twisted waveguide. Pay particular attention to fitting the waveguide gasket
on the coupler.
4 Four M10 socket cap screws
(16/17 mm box wrench + 8 mm Allen key)
Antenna port
2
Four M6 socket cap screws
(5 mm Allen key)
1
3
Reassembly
--
--
Fit the side-mounted nose and the four M3 screws 2 in their positions,
Fit the four M6 screws 3 in their positions on the side-mounted nose,
Tighten the M3 screws and then the M6 screws,
Fit the front-mounted nose and the four M6 screws 1 , and tighten,
-------
3CC14295AGAA TQ BJA 01
13 GHz : 3CC07725AAxx
15 GHz : 3CC07998AAxx
18 GHz : 3CC11263AAxx
38 GHz : 3CC08024AAxx
325/374
Vertical
Polarization
Horizontal
Polarization
326/374
3CC14295AGAA TQ BJA 01
2)
Remove the first rotative piece to access the second rotative piece :
6) Stick the label H delivered with the coupler to identify the polarization
The coupler is now configured in Horizontal polarization.
3CC14295AGAA TQ BJA 01
327/374
7.14
--
Note:
This procedure enables to evolve from the LUX12/LUX 50 version.
-- Power down the main IDU and disconnect it from the power source.
--
--
Open the locking and extract the SIMM board (if any) (Photo ).
--
Note: Not applicable for the light IDU. The IDU Light LUX 12 has no SIMM board.
Insert the two LUX 50 SIMM boards one after the other (Photo ).
--
--
--
--
--
Locking
SIMM memories
328/374
3CC14295AGAA TQ BJA 01
7.15
--
--
Power down the main IDU and disconnect it from the power source.
--
--
Change the battery (see Figure 229 or 230 depending on the type of IDU). The battery simply plugs
into the printed circuit board.
--
--
--
--
Wait for the ATT, URG and NURG LEDs to start flashing simultaneously on the main IDU and reload
the configuration from the ODU by pushing the IDU--ACO/ODU switch on the IDU connector panel
to the ACO/ODU setting. After two minutes at most, the LEDs should stop flashing simultaneously.
--
3CC14295AGAA TQ BJA 01
329/374
Display panel
MAIN IDU
Connector panel
P502
C512 C507
MX508
MX504
SW506
CR509
MX511
MX513
BATTERY
SW508
1
RAM
memory
J503
Flash memory
72
C531
1
2
MX514
J502
Y502
SW503
1
2
2
1
C509C504
2
1
C511 C506
1
6
1
6
MX507
C510C505
5
9
5
9
SW502
DS501
S502
S501
SW511
CR514
72
Figure 229 - Position of the battery on the MCU board (classic IDU)
C101
Y101
MX106
MX107
J102
IDU
MX119
MX118
MX117
CR101
Connector panel
CR102
SW103
CR103
MX126
CR104
MX127
MX128
MX129
J103
J104
BATTERY
RAM memory
72
Flash memory
72
Figure 230 - Position of the battery on the light MCU board (Light IDU)
330/374
3CC14295AGAA TQ BJA 01
--
Identify the orientation of the fan and extract the fan off its recess (Photo ).
--
Note the polarities and then disconnect the two fan power supply wires (Photo ).
--
Connect the power supply wires of the replacement fan (the red wire must be connected to the positive
terminal, marked on the PCB (Photo )).
--
Insert the new fan in its recess, the same way round as the one removed previously, and with the power
supply wires run along the same path.
--
--
--
--
Check that the fans extract air (otherwise, reverse their orientation).
--
3CC14295AGAA TQ BJA 01
331/374
Fans
red
black
Fan polarity
332/374
3CC14295AGAA TQ BJA 01
--
Power down the IDU and disconnect it from the power source.
--
--
Remove the suspect fuse and check it with an ohmmeter (if out of service: infinite impedance).
--
--
--
--
--
3CC14295AGAA TQ BJA 01
333/374
334/374
3CC14295AGAA TQ BJA 01
--
Introduction
This document explains the precautions that are taken to make sure the electromagnetic waves transmitted by
Alcatel 9400 family of equipment for Low and Medium Capacity Fixed Radio links are harmless for the public.
It provides an evaluation of a safety parameter based on calculations derived from the ICNIRP Guidelines and
the means (i.e. installation rules) by which this safety parameter has to be implemented, where necessary.
It applies to the protection of the public from electromagnetic field radiated by the transmit antenna of the
equipment. It does not apply to the protection of the workers.
The calculations, based on far--field telecommunications equations, provide, in case this hypothesis is not
validated by the result, an over--estimated value for the safety limit in the boresight direction of the antenna.
In this latter case, more realistic evaluations could be derived from near--field calculations, provided that an
adequate model of the antenna is used.
Where several radio equipment are installed on the same site, the contributions from each of them have to be
taken into account for the definition of the global safety parameter. Each radio site is then a particular case and
the safety parameter is no more depending on the characteristics of a single equipment only.
A.1.2
--
3CC14295AGAA TQ BJA 01
335/374
A.1.3
--
As far as ALCATEL 9400 infrastructure is concerned, the level of human exposure to electromagnetic waves
is characterized by the power density, which represents the basic restriction at those frequencies.
The following formula gives the power density assuming far field propagation of RF fields in free space. Then,
the power density at a distance D in the main lobe of an antenna of gain G with an input power Pf is:
DP=
Pf G
4 D2
(1)
Far field propagation assumption is valid at a distance equal to or higher than Dff from the antenna such that
Dff>2D2/, where D is the largest dimension of the antenna and the wave length.
Considering antennas with high gain, the safety parameter is first evaluated in the direction of the main lobe.
The distance DL where exposure level may reach the exposure limit DPL is provided by formula (2).
DL (m) =
PfG(W )
4 DPL(W / m2)
(2)
Formula (2) overestimates the safety distance if it is lower than the far field distance Dff.
336/374
3CC14295AGAA TQ BJA 01
A.1.4
--
Safety perimeters
Based on the maximum power of the equipment, the following table gives the safety distances for the general
public. Theses distances are valid for 1+0 and 1+1 configurations.
If the transmitted power changes (see 7.12), the safety distance can be calculated using the formula given
in Appendix 1.3 above.
Equipment
9413 UX
9413 UX 16 QAM
9415 UX
9415 UX RTPC
9418 UX
9418 UX
Frequency range
(GHz)
12 75 13 25
12,7513,25
12 75 13 25
12,7513,25
14,415,35
,
,
14,415,35
,
,
17,719,7
,
,
17,719,7
,
,
3CC14295AGAA TQ BJA 01
Antenna
gain
(dBi)
Maximum
power
(dBm)
Safety Distance in
front of the antenna
(meters)
35,3
25
2,9
38,3
25
4,1
41,5
25
45,1
25
35,3
21
1,8
38,3
21
2,6
41,5
21
3,8
45,1
21
5,7
31,1
21
1,1
36,5
21
2,1
40
21
3,2
42,5
21
4,2
46
21
6,3
31,1
24
1,6
36,5
24
40
24
4,5
42,5
24
46
24
8,9
33,3
16,5
0,9
38,6
16,5
1,6
42,1
16,5
2,4
44,6
16,5
3,2
47,8
16,5
4,6
33,3
24,5
2,2
38,6
24,5
42,1
24,5
44,6
24,5
47,8
24,5
11,6
337/374
Equipment
9423 UX 4QAM
Q
9423 UX 16QAM
Q
Frequency range
(GHz)
21,223,6
,
,
21,223,6
,
,
9425 UX 4QAM
24 5 26 5
24,526,5
9425 UX 16QAM
24 5 26 5
24,526,5
9438 UX 4QAM
37 39 5
3739,5
9438 UX 16QAM
37 39 5
3739,5
338/374
Antenna
gain
(dBi)
Maximum
power
(dBm)
Safety Distance in
front of the antenna
(meters)
34,9
19
1,4
40,1
19
2,5
43,6
19
3,8
46,1
19
5,1
49,4
19
7,4
34,9
17
1,1
40,1
17
43,6
17
46,1
17
49,4
17
5,9
36
18
1,4
41,1
18
2,5
36
16
1,1
41,1
16
39,6
16
1,7
44,5
16
39,6
14
1,4
44,5
14
2,4
3CC14295AGAA TQ BJA 01
A.1.5
--
In order to comply with the previously mentioned distance constraints, a safety parameter must be materialized
along with the proper regulatory signaling and warning,
unless the following mounting rules could be implemented for the antennas or outdoor equipment with
embedded antennas; they must be placed:
-- At the edge of the roof in a position such as nobody can sit or stand in front of the antenna within the
applicable distance mentioned above.
OR
--
Against an outside wall or under a roof, with no obstacle within 2 meters in the direction of the signal
transmission, taking into account the antenna aperture.If the antenna is placed on a balcony, it should
be placed in a position such as nobody can pass in front of it. This means that: either the equipment
is fixed on the outside wall, not on the wall between the balcony and the building, and pointed toward
the outside with no obstacle within 2 meters; or the access to the balcony must be closed and proper
marking used.
OR
If none of these mountings is possible, then a safety parameter must be materialized along with the proper
regulatory signaling and warning.
These rules apply to the general public and therefore do not apply in case the equipment is installed in
professional premises of an Operator with no access to the public, provided that the access to the so defined
area around the equipment be restricted to workers having received an adequate information on EMF risks.
These constraints are based on a theoretical general worst case study.
A.1.6
--
Conclusion
Alcatel 9400 transmit non--ionizing electromagnetic waves at a very low power, not exceeding 1 Watt at lower
frequencies.
Our installation rules make sure that it is impossible for anybody to sit or stand in front of the antenna within these
distances either by the physical position of the antenna or with a safety parameter.
These installation rules are followed by our installation teams and any of our sub--contractors and are they part
of the instructions delivered along the equipment for installation by our customers or by third parties.
3CC14295AGAA TQ BJA 01
339/374
Extension
Access
IDU N_
ODU N_
Software version
Power supply
24 V
48 V
Hardware configuration
Max config.
Max capacity
1+0
with ESC ext
1+1 HSB
1 antenna
TPC
1+1 HSB
2 antennas
1+1
Frequency div.
Modulation
Tributaries
Terminal bit rate (Limited by the interface boards and the
software key installed)
2 x 2 Mbit/s
4 x 2 Mbit/s
8 x 2 Mbit/s
16 x 2 Mbit/s
1 x 34 Mbit/s
4 inputs
2 Mbit/s
8 inputs
2 Mbit/s
16 inputs
2 Mbit/s
34 Mbit/s
+ 2 Mbit/s
Tributary
Name
Impedance
BNC-1.6/5.6-Terminal block
Tributary
N_ 1
N_ 2
N_ 3
N_ 4
N_ 5
N_ 6
N_ 7
N_ 8
N_ 9
N_ 10
N_ 11
N_ 12
N_ 13
N_ 14
N_ 15
N_ 16
Name
Impedance
BNC-1.6/5.6-Terminal block
2 Mbit/s aux.
Impedance: 75 or 120 Ohms for 2 Mbit/s channels only.
Tributary cross connect
340/374
If no particular matrix is supplied by the network administrator, use the standard configuration.
3CC14295AGAA TQ BJA 01
Radio configuration
Standby
channel
Normal channel
Polarisation (H/V)
MHz
Value between zero (default) and 31, inserted in transmission and awaited in re
reception, supplied by the network administrator
Transmit
Receive
Standard power
High power
0 dB
3 dB
Normal
Standby
dBm
dBm
Amplifier
(15 and 18 GHz bands only)
Output attenuator
(13, 15 and 18 GHz bands only)
Output power control
(13, 23, 25 and 38 GHz bands only)
Absent
Local loop
(Option)
Present
Absent
6 dB
10 dB
Present
Supervision
Superv. bit
rate
NE physical address
Apply standard configuration unless a specific matrix is supplied by the network administrator
Station telephone
N
Input level
Output level
Caution! No more than one zero in the number. Value supplied by network administrator.
dBm
dBm
Absent
Inte
ter termina
nal cab
able*
Present
Definition of ESCs
S ESC N_ 3
S ESC N_ 4 (Bit rate > 2 x 2 Mbit/s)
S ESC N_ 5 (Bit rate > 2 x 2 Mbit/s)
V28
ESC-1, 2, 3, 4 or 5
64 kbit/s V11
V11
ESC-1, 2, 3, 4 or 5
64 kbit/s V11
* Check the boxes for which the inter-- terminal link cables need to be installed.
Performance thresholds (triggering alarms)
Early switching request
2 x 2 Mbit/s
4 x 2 Mbit/s
8 x 2 Mbit/s
16 x 2 Mbit/s
1 x 34 Mbit/s
--93 dBm
--
--90 dBm
--86 dBm
--87 dBm
--83 dBm
--84 dBm
--79.5 dBm
--84 dBm
--79.5 dBm
Early
switching request
Performance
switching request
Priority
switching request
1E --08
1E --06
1E --03
S Terminal values
Bit error ratio
S Average values
S Terminal values
3CC14295AGAA TQ BJA 01
341/374
Name
NO/NC
Loop
TS N_ 1
TS N_ 2
TS N_ 3
TS N_ 4
TS N_ 5
TS N_ 6
TS N_ 7
TS N_ 8
Name
NO/NC
TC N_ 1
Specify the default alarm, equipment and environment alarms (UG, NURG, Disabled, Status).
G784 thresholds
Threshold
BBE
ES
SES
UAS
Value
342/374
3CC14295AGAA TQ BJA 01
DESCRIPTION
QUANTITY
1AC000570017
1m
1AC000570010
1m
1AC001250004
1m
1AD012980002
100
1AD012980003
50
77081203
77091318
50
77094664
1m
3CC14295AGAA TQ BJA 01
343/374
A.4.1
The service kit is used when pointing the antennas of each station. It comprises:
-- a cable for connecting to the MAINT connector on the ODU, ref. : 9400UXT102, 3CC07972AAxx
--
a headset/microphone assembly for links with the indoor unit and the remote station for using the
telephone service channel ESC 2, not available for use with the Light IDU versions, ref.:
1AF00375ABAA.
Cable fixing
P05
P01
P04
3 -- Speaker P
4 -- Speaker N (ground)
P02
--
--
Connector P04 : Connector for portable PC, reserved for Alcatel use.
--
Connector P05 : Connector for headset (cannot be used with Light IDU versions).
Right earphone
Left earphone
344/374
3CC14295AGAA TQ BJA 01
A.4.2
--
The short service kit 3EJ04113AAAA is used when pointing the antennas of each station. It comprises a cable
for connecting to the MAINT connector on the ODU, ref.: 3CC13477AAxx.
P05
P01
P02
P04
P03
--
--
--
Connector P05: connector for portable PC. To be used for maintenance purpose or necessity to
upgrade the ODU embedded software.
3CC14295AGAA TQ BJA 01
345/374
--
Connector BECLER
BK / 224
Square, 18 mm
across flats
Hex, 20 mm
across flats
Hex, 20 mm
across flats
re
NOT
MELT
THE
CABLE
346/374
3CC14295AGAA TQ BJA 01
A.5.2
--
3CC14295AGAA TQ BJA 01
347/374
Main IDU
Access IDU
Z
A
U
T
O
Extension IDU
Light IDU
348/374
3CC14295AGAA TQ BJA 01
A.6.1
--
Tributaries
Connector
2 Mbit/s tributary N
Pin
10
11
12
13
14
15
16
In+
In-
21
22
23
24
25
26
27
28
21
22
23
24
25
26
27
28
Out
+
12
13
14
15
16
17
18
19
12
13
14
15
16
17
18
19
Out
-
30
31
32
33
34
35
36
37
30
31
32
33
34
35
36
37
4 x 2 Mbit/s boards
LAU: 3CC06058Axxx
LIU: 3CC05818Axxx
8 x 2 Mbit/s boards
16 x 2 Mbit/s boards
Access board
Ground pins:
LAU: 3CC06765AAxx (requires the same configurations in main and extension IDUs)
10,29 on I/O (1/8) and I/O (9/16) of the main IDU and access IDU,
6, 7, 8, 9, 10, 11, 16, 17, 18, 19, 20, 25, 26, 27, 28, 29, 34, 35, 36, 37 on I/O 1 - 4 of the Light IDU
In 75 ohms version, In+, Out+ are the live input and output pins and In-, Out- are the ground pins for the same signals.
Depending on the boards installed, some connector pins may not be available (areas shaded in the table).
For the main and access IDU:
-- The pins 1 &11 must be not connected.
--
If the connector system required for the 34 Mbit/s system is BNC, use a BNC/ 1.6/5.6 adapter kit
ref: 3CC08249AAxx (option).
1.6/ 5.6 connector
34 Mbit/s port
I / O ( 9 / 16 )
Auxiliary 2 Mbit/s
port
3CC14295AGAA TQ BJA 01
349/374
--
In+
In--
Out+
Out--
LAU: 3CC06061AAxx
LIU: 3CC06118AAxx
28
19
37
Pin 10: ground; in 75 ohms configurations, In+ and Out+ are the live input and output pins and In- and Out-
are the ground pins for the same signals.
350/374
3CC14295AGAA TQ BJA 01
--
A.6.2
Signal
Pin
Signal
Ground
Signal
Pin
Signal
M--wire signal
0V
E--wire signal
+5 V protected
Out+ pin
Out-- or 0 V pin
23
Unprotected +5 V
11
24
Ground
12 -- 30
20
3 -- 6 -- 22 -- 25
21
3CC14295AGAA TQ BJA 01
Pin
351/374
A.6.2.3.2 -- Without extension unit: ESC EXT connector on the main IDU
ESC4
ESC5
Out+
pin
Out-- or 0 V
pin
Out+
pin
Out-- or 0 V
pin
Out+
pin
Out-- or 0 V
pin
20
26
13
32
21
27
14
33
22
28
23
10
29
15
34
24
11
30
16
35
25
12
31
17
36
0 volt (ground)
18
19
37
ESC4
ESC5
Out+
pin
Out-- or 0 V
pin
Out+
pin
Out-- or 0 V
pin
Out+
pin
Out-- or 0 V
pin
23
10
29
15
34
24
11
30
16
35
25
12
31
20
26
13
32
21
27
14
33
22
28
17
36
0 volt (ground)
18
19
37
352/374
3CC14295AGAA TQ BJA 01
ESC3
Pin
Analogue ESC
signal
G703 64 kbit/s
signal
Pin
Analogue ESC
signal
Output (+)
N.C.
N.C.
Input (+)
Audio 1 (+) IN
N.C.
Audio 2 (+) IN
Input (--)
Audio 1 (-) IN
N.C.
Audio 2 (-) IN
N.C.
N.C.
N.C.
N.C.
N.C.
E signal 1
N.C.
E signal 2
N.C.
N.C.
N.C.
N.C.
N.C.
M signal 1
N.C.
M signal 2
Ground
Ground
Ground
Ground
64 kbit/s
Data In (+)
Data In (--)
NC
NC
NC
NC
Clk In (+)
NC
NC
Clk In (--)
NC
NC
Ground
Ground
Ground
Ground
Ground
N.C. = Not Connected ; PM = Point-to-Multipoint ; PP = Point-to-point ; * In V28 mode, all the (--) signals are
grounded.
3CC14295AGAA TQ BJA 01
353/374
64 kbit/s
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
NC
Ground
Ground
Ground
Ground
Ground
In--
Out+
Signal
Out--
1, 4, 8, 14,
15, 20
6, 7, 9, 16,
17, 18, 19,
21
ESC 5: Clock
ESC 5: Data
Pin
10
22
12
24
0 volt
11
23
13
25
Not connected
2, 3, 5
In+ and Out+ are the live input (received signal) and output (transmitted signal) pins and In-- and Out--
are the ground pins for the same signals.
354/374
3CC14295AGAA TQ BJA 01
A.6.3
--
The alarm and remote control relays are de--energized in the absence of an alarm.
The remote indication loops (TS) between electrical ground and TS input, can be configured as normally open
or normally closed (in the absence of an alarm), depending on the positioning of the soldered links (swaps)
on the MCU board, as indicated in section 7.10.
N/O contact
Common contact
Pin
Pin
Pin
14
15
32
TS1 input
33
34
16
TS2 input
26
17
18
35
TS3 input
36
37
19
TS4 input
27
Signal
Unprotected +5 V
Ground
R
Reserved
d for
f ALCATEL
TS signals
11
TS5 input
12 -- 30
TS6 input
28
TS7 input
10
TS8 input
29
3 -- 6 -- 22 -- 25
N/O
contact
Common
contact
Pin
Pin
Pin
14
TS1 input
TS5 input
15
16
TS2 input
20
TS6 input
22
Signal
TS signals
Pin
Pin
17
TS3 input
TS7 input
10
18
19
TS4 input
21
TS8 input
23
0V
3CC14295AGAA TQ BJA 01
25
11 -- 12 -- 13 -- 24
355/374
--
IDU F connector
Use of the F connnector requires the F connector adapter cable between the PC cable and the IDU female
9--pin sub--D port.
ASSIGNMENT
Pin
ASSIGNMENT
Request to send
Clear to send
GND
Not connected
P2
1
2
Male plug
356/374
Female plug
3CC14295AGAA TQ BJA 01
A.6.4
Maintenance
CRI
Critical alarm
immediate
MAJ
Synthesis of
troublshooting.
immediate
MIN
Warning alarm
IND
Indeterminate alarm
EXT
External Point
(Housekeeping alarm)
EQP
Equipment alarm
TRS
Transmission alarm
NE reachable/unreachable
SUP
Supervision state
ALI
Alignment
OS
OS Management
AC
Abnormal Condition
WNG
COM
NTP
3CC14295AGAA TQ BJA 01
alarms
that
needs
357/374
The following table summarizes the information obtained in the alarm view starting from the left column.
Alarm information, general description
TITLE
DESCRIPTION
Severity
severity associated with the alarm and assigned in the Alarm Profile
Event time
Entity
Probable Cause
The information supplied helps the operator during the troubleshooting operations.
Table on page supplies general information on the alarm meanings and on the respective maintenance actions
to be taken based on the information given in the applications.
The maintenance action must take into account the board where the alarm is detected.
The Housekeeping alarms are referred to the input external point relevant to the Housekeeping signals. They
are available to the customer by connecting them to a dedicated subrack connector.
358/374
3CC14295AGAA TQ BJA 01
MEANING
MAINTENANCE ACTION
AIS
Cable LOS
Dem fail
Dem LOS
Early Warning
High BER
Excessive BER
Incompatible Frequency
Incompatible PTX
Loss Of Signal
Low BER
Mod fail
Mod LOS
PPP Fail
Provisioning Mismatch
3CC14295AGAA TQ BJA 01
with
359/374
ALARM
MEANING
MAINTENANCE ACTION
No RF received signal
Threshold Cross
Unavailable Time
Performance alarm:
unavailable seconds
Transmitter failure
Unconfigured Equipment
Present
Housekeeping
360/374
Too many
3CC14295AGAA TQ BJA 01
A.9.1
--
Hardware
Outdoor equipment 94xxUX flat
ODU
Mnemonic
4QAM/16QAM RTPC
Outdoor unit 9413 fs=266MHz 1--1
Outdoor unit 9413 fs=266MHz 2--2
Outdoor unit 9413 fs=266MHz 1--1
Model number
& Remote Inventory
numbers
3CC13688AAxx
3DB05524AAAA
3CC13689AAxx
3CC13690AAxx
3CC13691AAxx
3CC13692AAxx
3DB06633AAAA
3CC13693AAxx
3CC13694AAxx
3CC13695AAxx
3CC13696AAxx
3DB05526AAAA
3CC13697AAxx
3CC13698AAxx
3CC13699AAxx
3CC13704AAxx
3DB05525AAAA
3DB06334AAAA
3CC13709AAxx
3CC13711AAxx
3DB05527AAAA
3CC13706AAxx
3CC13707AAxx
3CC13705AAxx
3CC13712AAxx
3CC13713AAxx
3CC12991AAxx
3DB05227AAAA
3CC12992AAxx
3CC12993AAxx
3CC12994AAxx
3CC13714AAxx
3DB05228AAAA
3CC13715AAxx
3CC13716AAxx
3CC13717AAxx
3CC13468AAxx
3DB05530AAAA
3CC14295AGAA TQ BJA 01
3CC13469AAxx
3CC13470AAxx
3CC13471AAxx
361/374
Mnemonic
4QAM/16QAM RTPC
Outdoor unit 9418 fs=1092.5MHz 1--1
3CC14472AAxx
3CC14473AAxx
3CC14474AAxx
3CC14475AAxx
3DB05229AAAA
3CC12995AAxx
3CC12996AAxx
3CC13718AAxx
3DB05532AAAA
3CC13719AAxx
3CC13720AAxx
3CC13721AAxx
3CC13726AAxx
3DB05531AAAA
3CC13727AAxx
3CC13728AAxx
3CC13729AAxx
3CC14388AAxx
3DB05533AAAA
3CC14389AAxx
3CC14390AAxx
3CC14391AAxx
3CC13734AAxx
3DB05534AAAA
3CC13735AAxx
3CC13736AAxx
3CC13737AAxx
3CC12987AAxx
3DB05225AAAA
3CC12988AAxx
3CC12989AAxx
3CC12990AAxx
3EJ04472AAAA
3CC13472AAxx
3EJ04473AAAA
3CC13473AAxx
3EJ04474AAAA
3CC13474AAxx
362/374
Model number
& Remote Inventory
numbers
Mnemonic
Model number
Remote
Inventory
numbers
3CC08879xxxx
9413UXR202 3CC12690AAxx
3CC11737xxxx
9413UXR203 3CC12683AAxx
3CC11736xxxx
9415UXR201 3CC08880AAxx
3CC08880xxxx
9415UXR202 3CC08978AAxx
3CC08978xxxx
3CC14295AGAA TQ BJA 01
Mnemonic
Model number
Remote
Inventory
numbers
9415UXR203 3CC12979AAxx
3CC12978xxxx
9418UXR201 3CC08883AAxx
3CC08883xxxx
9418UXR202 3CC08979AAxx
3CC08979xxxx
9423UXR201 3CC08888AAxx
3CC08888xxxx
9423UXR202 3CC13031AAxx
9425UXR201 3CC08889AAxx
9425UXR202
3CC12684AAxx
3CC11743xxxx
9438UXR201 3CC08890AAxx
3CC08890xxxx
9438UXR202 3CC13032AAxx
3CC12797xxxx
9413UXR111
3CC07985AAxx
3CC07985AAxx
9415UXR111
3CC07999AAxx
3CC07999AAxx
9418UXR111
3CC08134AAxx
3CC08134AAxx
942xUXR111
3CC07987AAxx
3CC07987AAxx
943xUXR111
3CC08000AAxx
3CC08000AAxx
3CC14295AGAA TQ BJA 01
3CC12755xxxx
or
3CC12756xxxx
3CC08889xxxx
363/374
A.9.2
--
Mnemonic
Model number
3EJ03625AGAA
3CC09426ACxx
3EJ03625AHAA
3CC09426ACxx
3EJ03619ADAA
3CC08973Axxx
3EJ03618ADAA
3CC08972Axxx
3EJ03617ADAA
3CC08971Axxx
3EJ03626ADAA
3CC08920Axxx
9400UXB211
3CC08897Axxx
9400UXB221
3CC08898Axxx
9400UXB231
3CC08976Axxx
9400UXB232
3CC08975AAxx
9400UXB233
3CC08974AAxx
9400UXB234
3CC08908AAxx
9400UXB144
3CC08977AAxx
9400XXB007
3CC07619ABxx
Comments
3CC08048ABxx
3EJ03500AAAA
3CC14311AAxx
Craft Terminal
946LUX50
CD--ROM
3EJ03500ABAA
3CC14134AAxx
3EJ03500ACAA
3CC14311AAxx
9400UXD103
3CC12903AHAA
364/374
Cable Adapter
CT--IDU LUX50
3CC14295AGAA TQ BJA 01
A.9.3
--
Commercial items
This table maps the various items in the installation manual to the commercial references by which they are sold.
The composition of each item is given by way of indication; the definitive list is generated according to the
equipment configuration.
OUTDOOR PARTS
Installations
Mnemonic
Model number
Comments
9400UXI102
3CC10752AAxx
9400UXI101
3CC06071AAxx
Wind strengthening
9400UXI103
3CC11453AAxx
Optional
9413UXI102
1AB146090003
Adapter nose
1AB128510002
Support
9413UXI103
3CC05751ACxx
Flextwist 13 GHz 60 cm
9415UXI102
1AB146090001
Adapter nose
1AB128510002
Support
9415UXI103
3CC05750ACxx
Flextwist 15 GHz 60 cm
9418UXI102
1AB146090002
Adapter nose
1AB128510002
Support
9418UXI103
3CC05749ACxx
Flextwist 18GHz 60 cm
942xUXI102
1AB146090004
1AB128510002
Support
9423UXI103
3CC05749ACxx
Flextwist 23 /25GHz 60 cm
9413UXI002
3CC06215AAAB
9415UXI001
3CC10952AAxx
9415UXI002
3CC06321AAAB
9418UXI001
3CC10953AAxx
9418UXI002
3CC06628AAAB
9423UXI001
3CC06217AAAB
9423UXI002
3CC06216AAAB
9425UXI001
3CC06629AAAB
9425UXI002
3CC06630AAAB
9438UXI001
3CC06631AAAB
9438UXI002
3CC06632AAAB
9413UXR120
3CC08543AAxx
3CC08543ABxx
3CC08543ACxx
9413UXR112
3CC07725AAxx
9415UXR112
3CC07998AAxx
9418UXR112
3CC11263AAxx
942xUXR112
3CC11264AAxx
9438UXR112
3CC08024AAxx
Pipe
SUPOUTD001
3CC04658AExx
SUPMAST001
3CC05148AAxx
15 GHz
Outdoor fix pole mounting (non integrated antenna)
18 GHz
Outdoor fix pole mounting (non integrated antenna)
23 / 25 GHz
3CC14295AGAA TQ BJA 01
3 dB
6 dB
10 dB
365/374
INDOOR PARTS
Installations
Mnemonic
Model number
Comments
9400UXZ200
3CC11761AAxx
9400UXZ201
3CC12847AAxx
Contains 2 fans (5 V)
19 supporting rack
9400XXI300
1AD039050001
9400UXI301
3CC09614AAxx
3CC07966AAxx
3CC07957AAxx
9400UXI302
1AD029510001
9400UXI303
3CC08295AAxx
9400XXC511
1AD053060001
3CC08211AAxx
3CC08165AAxx
48 V
9400XXC511
1AD053060001
3CC08209AAxx
3CC08212AAxx
24 V
9400XXC512
77096248
3CC08165AAxx
3CC08211AAxx
48 V
9400XXC512
77096248
3CC08209AAxx
3CC08212AAxx
24 V
Consumable set
9400UXT002
3CC06503AAxx
9400UXT102
3CC07972AAxx
1AF00375ABxx
9400UXT112
3CC07972AAxx
Cable
3EJ04113AAAA
3CC13477AAxx
9400UXT103
3CC08409AAxx
Telephone handset
9400XXB000
3CC07946AAxx
INFRA00003
3CC07580AAxx
INFRA00004
3CC06511AAxx
INFRA00005
3CC06512AAxx
INFRA00006
3CC06759AAxx
Battery
M4T28--BR12--SH1
1AB084760003
The following table maps the various items in the installation manual to the commercial references by which they
are sold. The composition of each item is given by way of indication; the definitive list is generated according
to the equipment configuration.
366/374
3CC14295AGAA TQ BJA 01
CABLING
Installations
Mnemonic
Model number
Comments
9400UXC130
3CC07157ABxx
9400UXC333
3CC08729AAxx
9400UXC332
3CC07711AAxx
Supervision
9400UXI202
1AC001100022
Per 50 m
9400UXI203
1AB095530021
9400UXI204
1AB128500002
Power supply
pp y connection kit
9400XXC501
3CC08165AAxx
48 V (per 20m)
3CC08209AAxx
24 V (per 20m)
9400XXC502
3CC08166AAxx
Per 20 m
9400XXI504
3CC08809AAxx
Per 15 m
9400XXI505
3CC07921AAxx
3CC05527AAxx
9400XXI506
3CC07917AAxx
Per 15 m
9400XXI508
3CC08811AAxx
Per 15 m
9400XXI509
3CC08817AAxx
Per 15 m
9400XXI404
3CC08061AAxx and
3CC07885AAxx or
3CC07885ADxx
9400XXI404
+ 1 x 9400XXI405
3CC08061ABxx and
3CC07759AAxx or
3CC07759ADxx
75 / BNC
9400XXI408
3CC08061AAxx and
3CC07885ABxx or
3CC07885AExx
75 / 1,6/5,6
9400XXI408
+ 2 x 9400XXI405
3CC08061ABxx and
3CC07759ABxx or
3CC07759AExx
75 / BNC
9400XXI408
3CC07810AAxx
3CC07658AAxx
120 EMC
9400XXI408
3CC08062AAxx
3CC07658AAxx
9400XXI416
3CC08061AAxx and
2x3CC07885ABxx or
2x3CC07885AExx
75 / 1.6/5.6
9400XXI416
+ 4 x 9400XXI405
3CC08061ABxx and
2x3CC07759ABxx or
2x3CC07759AExx
75 / BNC
9400XXI416
3CC07810AAxx
2x3CC07658AAxx
120 EMC
9400XXI416
3CC08062AAxx
2x3CC07658AAxx
9400XXI405
3CC08249AAxx
3EJ03500ABAA
3CC14134AAxx
BNC adapter
3CC14295AGAA TQ BJA 01
367/374
--
Software
CD--ROM
identification
Minimum
Item Change
Status (ICS)
3CC14311AAAA
03
Software
identification
Minimum
Item Change
Status (ICS)
3CC14057AAAA
02
Software
identification
Minimum
Item Change
Status (ICS)
3CC08538AAxx
06
3CC08755AAxx
04
3CC08540AAxx
07
Software
identification
Minimum
Item Change
Status (ICS)
3CC06452AJxx
04
ODU Flat
3CC13007AAxx
01
Commercial
Code
CD--ROM
identification
Minimum
Item Change
Status (ICS)
9400UXD103
3CC12903AHAA
01
A.10.2
--
Documentation
Documentation CD--ROM
Alcatel 9400UX
368/374
3CC14295AGAA TQ BJA 01
DEFINITION
Abnormal condition
ACO
Alarm cut-off
ADC
Analog/Digital Converter
AGC
AIS
ATPC
BBE
BER
BTS
CIA_NUM
CT
DCE
DTE
DTMF
ECT
EMC
ElectroMagnetic Compatibility
EPS
ES
Errored seconds
ESC
ESD
ElectroStatic Discharge
ESR
ETSI
FD
Frequency Diversity
FEC
FTP
HDB3
HDLC
HSB
Hot StandBy
IDU
InDoor Unit
IF
Intermediate Frequency
I2C
ITU
JRE
LAU
3CC14295AGAA TQ BJA 01
369/374
LED
LIU
LO
Local Oscillator
MCU_NUM
MDU
NE
Modulation/Demodulation Unit
Network Element
NMC
NMS
NSA
No Service Affecting
NTP
OCT
ODU
OutDoor Unit
OS
Operation System
OSPF
PCM
PRBS
PSU
RF
RTPC
RX
Receiver
SA
Service Affecting
SCU_NUM
SD
SES
SI
SNMP
SWP
Software Package
TMN
TX
UAS
UF
UX Flat ODU
VCXO
370/374
Transmitter
Unavailable seconds
Manufacturing unit
9400 UX with a Flat outdoor unit
Voltage Controlled Crystal Oscillator
3CC14295AGAA TQ BJA 01
INDEX
A
Alarm & Remote control, wiring, 107
Alarms, description, 42
Antenna
coarse alignement, 82
polarization, 77
Assembling, N type coaxial connectors, 340
Configuration, 22, 23
1+0, 30
1+1, 34
capacity, 28
changing, 271
hardware, 28
indoor unit, 292
multiplexer/demultiplexer protection, 36
remote indication loops, 309
service channels, 295
service channels 3, 308
software, 113
Configuration with non---integrated antenna,
installing, 94
Bit rate
changing by software, 284
changing via LAU/LIU boards, 285
C
Capacity, configuration, 28
Changing
1+1 coupler polarisation, 319
bit rate by software, 284
bit rate via LAU/LIU boards, 285
configuration, 271
fans, 325
frequency, 273
fuse, 327
IDU, 266
MCU board battery, 323
NE physical address, 288
ODU, 269
power level, 317
redundancy configurations, 312
SIMM memories, 322
software key, 288
tributaries, 274
tributary impedance, 283
Coarse alignment, antenna, 82
Commissioning
end, 263
equipment, 255
checking, 260, 261, 262, 263
order, 255
station A
(phase 1), 256
(phase 2), 261
station B, 259
3CC14295AGAA TQ BJA 01
D
Delivery, equipment, 63
Description
alarms, 42
equipment, 21
IDU/ODU cable, 32
loopback, 42
service channels, 38
telesignalling and remote controls, 42
E
Human exposure, Electromagnetic fields, 329
End, commissioning, 263
Engineering service channel, wiring, 106
Equipment
commissioning, 255
checking, 260, 261, 262, 263
delivery, 63
description, 21
features, 24, 27
grounding, 100
installing, 70
labels, 64
maintenance, 265
management, 44
operation, 265
servicing, 265
wiring, 99
371/374
equipment, 265
preventive, 265
Management, equipment, 44
Manual
structure, 13
using, 13
I
IDU
changing, 266
controls, indications and connectors, 45
Access version, 49
Classic version, 45
Extension version, 48
opening, 291
IDU/ODU, wiring, 102
IDU/ODU cable, description, 32
Indoor unit, configuration, 292
Installation
information, 334
tools, 70
Installing
equipment, 70
laborack, 72
Light IDU 19 version, 71
software, 114
wall mounting, 72
Item, list, 355
L
Labels, equipment, 64
Laborack, installing, 72
Light IDU 19 version, installing, 71
List
items, 355
models, 355
Loopback, description, 42
M
Maintenance
corrective, 265, 266
372/374
O
ODU
changing, 269
installing, 75
ODU 9400UX flat ODU, 87
installing, 97
ODU 94xxUXR201, 94xxUXR202, 94xxUXR203,
installing, 97
Installing, 87
configuration with non---integrated antenna, 94
ODU, 75
ODU 9400UX flat ODU, 97
ODU 94xxUXR201, 94xxUXR202, 94xxUXR203,
97
pole mounting
9400UXI101, 85
9400UXI102, 77
on the pipe, 82, 88
Opening, IDU, 291
Operation, 30
equipment, 265
software, 113
Order, commissioning, 255
P
Pin out, user ports, 342
Pointing the antenna
pole mounting 1+0, 9400UXI102, 260
pole mounting 1+1, 9400UXI101, 259
Polarization, antenna, 77
Pole mounting
9400UXI101, installing, 85
9400UXI102, installing, 77
on the pipe, 82, 88
Pole mounting 1+0 (9400UXI101), pointing the
antenna, 259
3CC14295AGAA TQ BJA 01
S
Safety, instructions, 14
Service channel, telephone, 294
T
Technical characteristics, 51
3CC14295AGAA TQ BJA 01
U
Upgrading, software, 289
W
Wall mounting, installing, 72
Wiring
alarm & remote control, 107
between a terminals units, 108
between terminals of a station, 111
engineering service channel, 106
equipment, 99
IDU/ODU, 102
tributaries, 104
373/374