NO ALARM

INFORMATION

7600 BCF FAULTY

Power unit is probably broken.


Fault in the chain between power unit and MHA.
BSS synchronisation failed.
Difference between PCM and base station frequency reference.

7601 BCF OPERATION DEGRADED

Incompatible unit presence detected in the BTS.


Rx levels differ too much between main and diversity antennas.
Power unit input voltage fault.
Fault in the chain between power unit and MHA.
1st branch LNA in dual variable gain duplex unit is faulty.
2nd branch LNA in dual variable gain duplex unit is faulty.

7602 BCF NOTIFICATION

Power unit temperature is dangerously high.


Mismatch between BSC/MMI configuration file and the actual
Cooling fan is broken.
No connection to power unit.
TSxx rack I2C bus is jammed.
Common rack EAC I2C bus is jammed.
Fan unit is broken.

7603 BTS FAULTY

There is disturbance in the serial DL bus or bus is broken


Antenna connection faulty.
The RF receiver frequency hopping synthesizer 1 is not locked.
Fault in the chain between power unit and MHA.
Master TRX detected that connection to slave TRX is lost.
BOI or TRX has detected a failure in the incoming frame clock

7604 BTS OPERATION DEGRADED

2nd branch LNA in dual variable gain duplex unit is faulty.


1st branch LNA in dual variable gain duplex unit is faulty.
Performance is degraded in 2nd branch dual variable gain
Performance is degraded in 1st branch dual variable gain
Fault in the chain between power unit and MHA.
TRX test result antenna connection faulty.
No connection to dual variable gain duplex unit.

7606 TRX FAULTY

Antenna connection faulty.


BOI detected that connection to TRX is lost.
Failure detected during TRX configuring.
The transmitter output power is too low.
The transmitter output power has dropped at least 3 dB.
The RF transmitter frequency hopping synthesizer 2 is not
The RF transmitter frequency hopping synthesizer 1 is not
Non EDGE TRX device type used accidentally in Edge Capable
The RF receiver frequency hopping synthesizer 2 is not locked.
The transmitter output power has dropped at least 3 dB.
Interface problems between O&M and EQDSP software or EQDSP
The system clock (26MHz) is not locked.
Master TRX detected that connection to slave TRX is lost.
The transmitter output of TRX is overdriven
TSxx temperature is dangerously high.

7607 TRX OPERATION DEGRADED

Rx levels differ too much between main and diversity antennas.


No connection to dual variable gain duplex unit.
TRX I2C -bus is jammed.

7608 TRX NOTIFICATION

TSxx has lost connection to temperature sensor.


BB2 has lost connection to temperature sensor.

Impossible to execute TRX loop.


7609 TRE FAULTY

BOI detected that connection to transmission unit lost.


Master TRX detected that connection to transmission unit lost.

7615 RTS IS IN TEST USE


7616 OSCILLATOR ADJUSTING TEMPORARILY INTER Oven oscillator adjustment function interrupted.
7622 CABINET OPEN

Cabinet cover is open.

7700 BTS OMU INITIALIZATION


7701 BCF INITIALIZATION
7701 BCF INITIALIZATION
7704 PCM FAILURE
7705 LAPD FAILURE
7706 BTS O&M LINK FAILURE
7711 WORKING FULL RATE TCH RATIO BELOW THRESHOLD
7712 WORKING SDCCH CHANNEL RATIO BELOW THRESHOLD
7715 CONTINUOUS RESTARTS OF BCF/TRX
7717 WORKING HALF RATE TCH RATIO BELOW THRESHOLD
7717 WORKING HALF RATE TCH RATIO BELOW THRESHOLD
7724 CONFLICT BETWEEN BSS RADIO NETWORK DATABASE AND CALL CONTROL
7725 TRAFFIC CHANNEL ACTIVATION FAILURE
7727 TRAFFIC CHANNEL NUMBER DECREASED
7728 OBJECT OUT OF USE BECAUSE OF ERROR IN BTS INTERNAL DIAGNOSTICS
7729 RADIO NETWORK RECOVERY FAILED
7730 CONFIGURATION OF BCF FAILED
7731 BCF SW PACKAGE MAY BE DIFFERENT AS DEFINED AS A DEFAULT IN BSC
7734 BCCH IS NOT AT PREFERRED BCCH TRX
7735 TRX TEST FAILED
7737 INCONSISTENT DATA IN RADIO RESOURCE MANAGEMENT STATE FILES
7738 BTS WITH NO TRANSACTIONS

7740 BEATING BTS ALARM


7741 MEAN HOLDING TIME ABOVE DEFINED THRESHOLD
7743 MEAN HOLDING TIME BELOW DEFINED THRESHOLD
7744 EXCESSIVE TCH INTERFERENCE
7745 CHANNEL FAILURE RATE ABOVE DEFINED THRESHOLD
7746 CH CONGESTION IN CELL ABOVE DEFINED THRESHOLD
7767 BCCH MISSING
7769 FAILURE IN UPDATING CELL SPECIFIC PARAMETERS TO PCU
7801 MMI CONNECTED TO BASE STATION
7995 MAINS BREAKDOWN WITH BATTERY BACK-UP
8000 POWER SUPPLY FAULT
8020 BLOCKED FROM USE
8045 NO OUTGOING SIGNAL
8050 LOSS OF INCOMING 2M SIGNAL
8060 NO INCOMING RADIO SIGNAL
8064 ALARM SIGNAL (AIS) IS RECEIVED
8066 ALARM INDICATION SIGNAL (AIS) RECEIVED
8081 LOSS OF FRAME ALIGNMENT
8086 LOSS OF CRC MULTIFRAME ALIGNMENT
8099 RECEIVED BIT ERROR RATIO (BER) > 1E-3

1
2
3
10

8102 RECEIVED BIT ERROR RATIO (BER) > 1E-6


8112 FREQUENCY ERROR
8137 OSCILLATOR FAULT
8139 SUBRACK HAS MISSING UNITS
8141 FORCED CONTROL ON
8142 INSTALLATION ERROR
8150 FAULT IN UNIT
8165 REAL TIME LOST
8179 FAR-END ALARM
8186 CONFIGURATION ERROR
8202 LOSS OF SUPERVISION CONNECTION
8221 VERSION MISMATCH

TO
FIELD BTS
FIELD BTS
FIELD BTS
FIELD TRANS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS
FIELD BTS

FIELD BTS
FIELD BTS
DISTURBANCE
FIELD BTS
FIELD BTS
DISTURBANCE
DISTURBANCE
DISTURBANCE
FIELD TRANS
FIELD TRANS
FIELD TRANS
RF & BSS
RF & BSS
FIELD BTS & BSS
RF & BSS
RF & BSS
BSS
BSS & FIELD
BSS & FIELD
FIELD
FILED &BSS
FIELD & BSS
BSS
BSS
BSS
BSS
FIELD BTS & BSS
FIELD BTS & BSS
FIELD BTS & BSS
BSS
FIELD TRANS
RF & BSS
RF & BSS
FIELD & BSS & RF
RF & BSS
RF & BSS
RF & BSS
FIELR BTS
BSS
DISTURBANCE
EXT ALARM
FIELD TRNAS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS

FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS
FIELD TRANS

ACTION
CHECK THE PWSB &BACK PLANE & JACK IN &OUT ELSE CHANGE THE PWSB

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


CHECK SYNC CABLE & AUTO DETECTION SETTINGS.
SYNCHRANISATION SET UP VERIFICATION ON THE SITE IF IT IS CORRECT GO UP BSC & CHECK IN ALL THE SITES F
METRO SITE &THOUGH ALL TRXS ARE SHOWING THE ALARM GENERATED .

NEEDS SITE VISIT


CHECK THE PWSB &BACK PLANE & JACK IN &OUT ELSE CHANGE THE PWSB

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


REPLACING OF DVGA
REPLACING OF DVGA
INCASE OF OUTDOOR BTS CHECK THE DOOR FAN FUNCTIONALITY
HARDWARE CHECK UP & VERIFICATION
CHECK THE COOLING FAN
CHECK THE PWSB &BACK PLANE & JACK IN &OUT ELSE CHANGE THE PWSB
METRO SITE &THOUGH ALL TRXS ARE SHOWING THE ALARM GENERATED .
CHECK FOR THE FAN UNITS
NO TRXS IN THE SLOT ELSE THE SLOT IS FAULTTY
VSWR ISSUE
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


IN METRO FACING THIS PB
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
REPLACING OF DVGA
REPLACING OF DVGA
REPLACING OF DVGA
REPLACING OF DVGA

IF MHA CHECK THE DC OUT TO IT ELSE REMOVE MHA IN HARDWARE CONFIGURATION


VSWR ISSUE
REPLACING OF DVGA
VSWR ISSUE
AFTER RESETTING TRX THE PB AGAIN ARAISES WHILE THE DOWN STE COMES UP
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
NEEDS TRX CHANGE.
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
AFTER AHOP DISABLE & SECTOR RESET T There is disturbance in the serial DL bus or bus is broken
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
NEEDS TRX CHANGE.
NEEDS TRX CHANGE. IF PB NOT SOLVED CHANGE BB2F.
IN METRO FACING THIS PB
NEEDS TRX CHANGE.
CHCEK FOR THE FAN UNITS

NEEDS SITE VISIT


REPLACING OF DVGA
METRO SITE &THOUGH ALL TRXS ARE SHOWING THE ALARM GENERATED .
CHCEK FOR THE FAN UNITS
CHCEK FOR THE FAN UNITS

NEEDS TRX CHANGE


BOI OR RRI MAY FAULTY
NEEDS JACK IN & OUT UNITL THE TRANSMISSION UNIT DETECTED
NEEDS BOI /VIFA CHANE

SITE MAY BE DOWN OR NEEDS SECTOR RESTART


RESET THE CHANNELS &CHECK
RESET THE CHANNELS &CHECK
NEEDS THE TRX CHANGE
NEEDS BCF OR SITE RESET.MAY BE SITE DOWN
NEEDS BCF OR SITE RESET.MAY BE SITE DOWN
ACTIVATE ON DEFAULT PACKAGE
CHECK , OBSERVE & CHANGE
NEEDS SITE RESET OR CLEAR THE ALARM
NEEDS SECOTR RESET. IS DUE TO HUGH CALLS IN THE SECTORS

DUE TO CONTINOUS MEDIA FLUUCTATION / CONTINOUS ALARM REPEATATION

NEEDS BOI CHANGE

SITE MAY DOWN


GIVE A SECTOR REST

CHECK RRI / ODU POWER SUPPLY


CC BANK ALARM

ENABLE CRC / DISABLE THE CHANNEL

SYNCHRANISATION SET UP VERIFICATION

FIND OUT RRI / ODU & CHANGE


CHANGE THE ODU
DUE TO CRC PB
CHANGE THE RRI/ODU /BOTH
REMOVE THE UNNECSSARY SUPERVISARY CHANNELS.

3RD LINE SUPPORT COMMENTS