2

SSW1:
SSW2:
SSW3:
SSW4:
SSW5:
SSW6:

80 VDC

C110B

110VDC

D110

189VDC

L1
T1

71
AC

72
AC

75

150W30R

BRC

L1

L3
T3

BC 74

73

KC

44

(WT-1)

6A/1000V 10W/470
BK-

RC15
1

B110

BC
2DLS
NDLS

E.STOP3

S106

(WB-14)

DL111
HDLR

Speed governor
Safe gear
Buffer
Broken rope switch
Emergency exit
Over speed protection for run up

BC

(CT1-15)

SSW5

SSW3

ST11

INS3-3: machineroom emergency running convert switch


E.STOP1: Emergency stop in pit bottom
E.STOP2: Emergency stop for car top
E.STOP3: Emergency stop in car
E.STOP4: Emergency stop for control cabinet
EK-1: Converting switch for emergency switch
SSW0: Hand winding

D1

DL110

SSW4

S103
SSW6

(MRS-10/WT-6)

S105

SSW2
(CT1-14/MRS-09)

S102
SSW1

S109

(WB-2/CT1-4)

ST10

A110

L2

1DLS

E.STOP2

S107

(WB-4/CT1-13)

E.STOP1

S104
DOLS

(WT-2/WB-11)

UOLS
(CT1-3)

INS3-3

CDLS

C114
EB-1

(NOTE: EMERGENCY RUNNING SHOULD BE OPERATED BY ELEVATOR SECIALIST)

(MRS-5)

T1

(MRS-6)

B110/C110B/D110

C110

SSW0

T2

S100

E.STOP4

S101
D

43

R1

(MRS-8)

A110

R1
BK+
(MRS-7)

MB

(SAFE CIRCUIT GOUND SHORT CONNECT PROTECTION)

3PHMR: Phase relay


D1: 35A/1000V Rectifier
NDLS: Hall door lock
CDLS: Car door lock
KC: Running contactor
BC: Brake contactor

MB: Mechanical brake


EB-1: Confirm switch for emergency running
UOLS: Upper limit
DOLS: Lower limit
1DLS: 1stFloor Door Look
2DLS: 2ndFloor Door Lock

MCM3 A1

Title

Size

Date:
File:

A4

Wiring diagram for safe and door lock circuit


Number

Revision

122
13-Jun-2010
Sheet of
Drawn By: 220VUPS-OKB.Ddb