You are on page 1of 23

Quartus II

Classic Timing Analyzer


ver.9.1

2010 6

1.
Quartus II Classic Timing Analyzer
Quartus II
Quartus II

Timing Analyzer

2.
2-1.
Quartus II

Quartus II

Processing Start Start Analysis & Synthesis

Tasks Analysis & Elaboration

Processing Start Compilation

Tasks

Compile Design

Page 1 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

2-2. Classic Timing Analyzer


Quartus II Classic Timing Analyzer TimeQuest
Classic Timing Analyzer Classic Timing
Analyzer
(1)
(2)

Assignments Timing Analysis Settings


Settings Use Classic Timing Analyzer during compilation OK

Cyclone IVCyclone III LSStratix IVArria II GX TimeQuest

TimeQuest EDISON (https://www.altima.jp/members/index.cfm)

Quartus II - TimeQuest

ver. 9.1

2010 6

Page 2 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

3.

1
2
2

Setting

Classic Timing Analyzer Wizard

3-1.

3-1-1. Setting

Assignments Timing Analysis Settings

Timing Analysis Settings Classic Timing Analysis Settings Category

Clock Settings Default required fmax

OK
ver. 9.1

2010 6

Page 3 of 23

Altima Corporation

Quartus II Classic Timing Analyzer


3-1-2. Classic Timing Analyzer Wizard

Classic Timing Analyzer Wizard


Assignments Classic Timing Analyzer Wizard

Next

Classic Timing Wizard


Yes No, I want to assign fmax for specific
clocks Next
3-2-2

tsuthtcotpd I/O

Default fmax Next

ver. 9.1

2010 6

Page 4 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

Next

Fmax

tsutco

Summary Finish

ver. 9.1

2010 6

Page 5 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

3-2.
3-2-1. Setting

Classic Timing Analyzer Settings 3-1-1

Clock Settings Individual Clocks

Individual Clocks New

New Clock Settings


1) Clock settings name
2) Applies to node Node Finder
Node Finder

3) Independent of other clock settings


4) Required fmax
5) Duty cycle (%) Duty
6) OK

Node Finder

Duty

ver. 9.1

2010 6

Page 6 of 23

Altima Corporation

Quartus II Classic Timing Analyzer


Node Finder

1)

Node Finder Filter

2)

List Nodes Found

Selected Nodes
3)

OK

*
AND

List

New

New Clock Settings Based on Derived Clock Requirements


ver. 9.1

2010 6

Page 7 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

Derived Clock Requirements Duty


OK New Clock Settings OK

Duty

OK

Classic Timing Analyzer Settings OK

ver. 9.1

2010 6

Page 8 of 23

Altima Corporation

Quartus II Classic Timing Analyzer


3-2-2. Classic Timing Analyzer Wizard

Classic Timing Analyzer Wizard 3-1-2

Node Finder

Next

Node Finder

Duty Next

Duty

New

ver. 9.1

2010 6

Page 9 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

Yes No
Next
Node Finder

Yes

Next

Duty

ver. 9.1

2010 6

Page 10 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

Next

Next 3-1-2

Summary Finish

ver. 9.1

2010 6

Page 11 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

4. tsutcotpdth
Quartus II Classic Timing Analyzer

Clock Setup Fmax

tsu to

tco to

tpd to

EDISON (https://www.altima.jp/members/index.cfm) Quartus II


Timing Analyzer

tsu

Fmax

tco

tpd

tsu th tco ( to )tpd

ver. 9.1

2010 6

Page 12 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

4-1.
4-1-1. Setting

Assignments Settings

Timing Analysis Settings Classic Timing Analysis Settings Category

Delay requirements

OK

ver. 9.1

2010 6

Page 13 of 23

Altima Corporation

Quartus II Classic Timing Analyzer


4-1-2. Classic Timing Analyzer Wizard

Assignments Classic Timing Analyzer Wizard

Next

Yes

3-1-2 Summary Finish

ver. 9.1

2010 6

Page 14 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

4-2.
4-2-1. tsu () / th
4-2-1.1.

Reg1
Data
Reg2

Reg3

Assignment Editor Assignments Assignment Editor

Category Timing Timing

To tsu / th
<<new>>

Node Finder

Filter Pins: input List Nodes Found

Selected Nodes

OK

ver. 9.1

2010 6

Page 15 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

Assignment Name tsu Requirement th Requirement

Value

File Save

4-2-1.2. to
to

Data Reg 1

Reg1
Data
Reg2

Reg3

Assignment Editor Assignments Assignment Editor

Category Timing Timing

From <<new>> Node Finder Data

ver. 9.1

Node Finder 4-2-1.1

2010 6

Page 16 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

To Reg1
<<new>> Node Finder Filter Registers post-fitting List
Nodes Found

Selected Nodes Node Finder OK

Assignment Name tsu Requirement th Requirement

Value

File Save

4-2-2. tco to
4-2-2.1.
tco 2

tco
Out1
Reg1
Out2
Clock

Reg2

Reg3

ver. 9.1

2010 6

Page 17 of 23

Out3

Altima Corporation

Quartus II Classic Timing Analyzer

Clock1

Reg1

Clock2

Reg2

Out1

Clock3

Reg3

Assignment Editor Assignments Assignment Editor

Category Timing Timing


To <<new>> Node Finder tco
Filter Pins output

Node Finder 4-2-1.1

Assignment Name tco Requirement

Value

File Save

4-2-2.2. to

Reg1
Out1
Clock

Reg2

Reg3

Assignment Editor Assignments Assignment Editor

Category Timing Timing

From <<new>> Node Finder Clock

To <<new>> Node Finder Out1


Filter Pins all

Node Finder 4-2-1.1

ver. 9.1

2010 6

Page 18 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

Assignment Name tco Requirement

Value

File Save

4-2-3. tpd

Data

Out1

Assignment Editor Assignments Assignment Editor

Category Timing Timing

From <<new>> Node Finder

To <<new>> Node Finder


Filter Pins all

Node Finder 4-2-1.1

Assignment Name tpd Requirement

Value

File Save

ver. 9.1

2010 6

Page 19 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

5. Help
To From Quartus
II Help
Help index

timing requirements list of Classic


Timing Analyzer Requirements

ver. 9.1

2010 6

Page 20 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

ver. 9.1

2010 6

Page 21 of 23

Altima Corporation

Quartus II Classic Timing Analyzer


Help
Quartus II ver.9.1 Help Web browser
1)

Tools License Setup Internet Connectivity

2) Web browser browser

ver. 9.1

2010 6

Page 22 of 23

Altima Corporation

Quartus II Classic Timing Analyzer

1.

2.

3.

4.

5.

222-8563 1-5-5 TEL 045-476-2155 FAX 045-476-2156

532-0003 3-4-30 17F TEL 06-6397-1053 FAX 06-6397-1054

451-0045 27-8 20F TEL. 052-533-0252 FAX. 052-533-0253

3210964 1-3-1 STM 10F TEL. 028-627-1071 FAX. 028-627-1072

ver. 9.1

2010 6

Page 23 of 23

Altima Corporation

You might also like