PROBLEM ENCOUNTERED IN BOILER M/V SINOTRADER

1. JUNE 17, 2016.06.17


QUINDAO WHEN CHANGE OVER M/E TO DO
THE V/V OF HIGH SUCTION AND LOW SUCTION OF SERVICE TANK IS CLOSE RESULTING THE BOILER TO TRIP, THE
PRESS OF DELIVERY OF F.O BURNING PUMP IS 5 AND DROP CAUSING THE BOILER TO TRIP..
..1E OPEN THE LOW SUCTION OF SERVICE AND THE PRESS OF BOILER GOES BACK TO NORMAL..
.
SOLUTION: OPEN THE LOW F.O SUCTION V/V OS SERVICE TANK AND CLOSE HIGH F.O SUCTION
HOW TO CHANGE BUNKER
PROCEDURES
1. CLOSE THE STEAM HEATING OF F.O. GOING TO M/E
2. AFTER THE TEMP. OF BOILER BELOW 90, YOU CAN NOW CHANGE OVER BY
A. OPENING THE D.O. V/V GOING TO M/E
B. CLOSE PNEUMATIC CONTROLLED V/V SUCTION V/V OFME/.
NOTE; IF CLOSE THE M/E CONS. IS IN D.O.
IF OPEN THE M/E CONS. IS F.O
3. CLOSE HIGH SUCTION OF F.O GOING TO M/E
4. DO NOT OPEN LOW SUCTION OF F.O BEC. IF CLOSE BOILER WILL TRIP BEC. NO F.O SUPPLY