Professional Documents
Culture Documents
5 PDF
5 PDF
7/11/12
11:34
Page 27
Vo l u m e 8 - N u m b e r 1 4 - N o v e m b e r 2 0 1 2 ( 2 7 - 3 4 )
Abstract
he aim of this study
was to examine the
performance of the cooling
system for the ITM 285
tractor manufactured in
Iran. Results showed that
present type of cooling
system wasn't suitable for
ITM 285 tractor and cause
augmentation of cooling
system temperature, up to
103C at 34.9 ambient temperature and the engine
over-heated. The cooling
system should be able to
cool the engine coolant
and hold its temperature
at a constant point (maximum 103C). After experi-
Performance Evaluation of
ITM 285 Tractor (4.248
Perkins Diesel Engine)
Cooling System and
Suggestion of a New Type of
Radiator
E. Akbariana1, Y. Ajabshirchia2,
F. Ranjbarc3
a
Department of Agricultural Machinery,
University of Tabriz,Tabriz, Iran
c
Department of Mechanical Engineering,
University of Tabriz,Tabriz, Iran
1
Tel.:+989352691856; Fax:+984912250574;
1
E-mail: Ayvaz.Akbarian@gmail.com
2
E-mail: yajabshir@tabrizu.ac.ir,
2
Tel: +984113392781
3
E-mail: sfrgg.ranjbar@yahoo.com,
3
Tel: +984113393046
1. Introduction
27
Akbarian
7/11/12
11:34
Page 28
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
28
Akbarian
7/11/12
11:34
Page 29
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
Regarding regression equations, it is possible to calculate the average air speed in front of a radiator. Engine
fan radius was 19 cm and distance from the centre of
radiator to radiator corners was 31 cm. By using Eq. (1)
and (2), it is possible to calculate the average air speed
in front of a radiator.
(1)
(2)
Dimension :
29
3
30
Flat
8
Akbarian
7/11/12
11:34
Page 30
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
Figure 4. (a) ACT with 6 blade in metal fan (b) ACT with 7 blade
in polyamide fan (c) ACT with 8 blade polyamide fan
(4)
The cooling test results were analyzed by Microsoft
Excel program. These results are shown in Figure 4.
Considering negligible standard deviation (about 0.51.5%) in measurements results, The average of data was
used in calculations.
o = 1 - (1 - fin)= 0.96
30
Akbarian
7/11/12
11:34
Page 31
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
(7)
By considering the relation between and NTU:
(8)
Based on calculation, NTU= 0.4492, the total heat
transfer coefficient was computed as follow:
(9)
For achieving fin, we convert selected rectangle element to a circle element as follow.
Figure 7. Two type of radiators selected for discussions (a) first type (b) second type
31
Akbarian
7/11/12
11:34
Page 32
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
The only variable parameter in new radiator calculations was radiator width that determines radiator
tube rows. For reaching reality conditions and high precision in results, any tube rows of radiator were considered as a separate radiator. By using Microsoft Excel
software Prandtel number, kinetic viscosity,Cp(air), air
density, Cp(water),
, f simulated by following equations and used in developed program.
(12)
Kinematic Viscosity=-1.1555E-14*T^3 + 9.5728E(13)
11*T^2 + 3.7604E-08*T - 3.4484E-06
Cp (Air) = 1.9327E-10*T^4 - 7.9999E-07*T^3 +
1.1407E-03*T^2 - 4.4890E-01*T + 1.0575E+03
(14)
(15)
Cp (Water) = T + 4115
(16)
(17)
(18)
(19)
32
Akbarian
7/11/12
11:34
Page 33
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
Conclusion
Regarding the developed program results, these selected two types of radiators for ITM 285 cooling system
enable the tractor to work in 46 C ambient temperature that cover many territories in the world.
Acknowledgements
The authors express their gratitude to Motorsazan and ITM Co. authorities for providing tractor cooling test
tools.
References
[7] J.A. Chen, D.F. Wang, and L.Z. Zheng, Experimental Study of Operating
Performance of a Tube-and-Fn Radiator for Vehicles, Journal of Automobile Engineering, 2001, pp 911-918.
[1] Georing C.A, Alan C.H, Engine and tractor power, fourth edition,
American Society of Agricultural Engineers (ASAE), 2004.
[2] Perkins engines company limited, Peterborough PE1 5NA England. 2005,
Perkins Installation Manual, Publication 801 ser 02801164.
[10] A.B. Greene, and G.G. Lucas, The Testing of Internal Combustio
Engines, London , English Universities P., 1969.
[11] Warren M. Rohsenow , James R Hartnett, and Young I. Cho, third edition,
Handbook of Heat transfer, McGrawHill, 1998.
33
Akbarian
7/11/12
11:34
Page 34
E. Akbarian, Y. Ajabshirchi, F. Ranjbar / ISESCO Journal of Science and Technology - Volume 8, Number 14 (November 2012) (27-34)
Nomenclature
mair
Vair
Arad
air
T1
Tamb
ACT
: Ambient Clearance Temperature (maximum ambient temperature for which the cooling system is
suitable (C)
: ratio of total heat transfer area of on side of the radiator to its volume (m2 / m3)
St
: Stanton number
ho
Uo
Re
: Reynolds number
Rw
FPI
Th(in)
Tc (in)
Tc (out)
Epsilon (Total)
NTU (Total)
Sigma
Alfa
Vo
: air pressure drop between in front of radiator and its backward (Pa)
Delta P (Sum)
: air pressure drop between in front of radiator and its backward while passing any
rows of radiator (Pa).
34