You are on page 1of 1

CU/PVC

NYAF

Flexible Copper Conductor, PVC Insulated


Applications:
Power cord or internal wiring with low mechanical stress for electrical
equipments, machineries, distribution panels, luminaires and other electrical
used in dry indoor premises, substitutes NYA.
Permanent instalation in conduit, inherently flame retardant in compliance
with IEC 60332-1.

Rated Voltage : 300/500 V


Standard Specification : SNI 04-6629.3 : 2006 (IEC 06)
Cable Size
(No. of core
x Conductor
Area)

Conductor
Make-up
(No.of wire
x Diameter)

20C
Conductor

nom.
(mm2)

nom.
(mm)

0.5
0.75
1.00

16 x 0.20
24 x 0.20
32 x 0.20

DC Resistance at
70C
Insulation

Current
Carrying
Capacity in
air 30C

Short
Circuit
Current
1 Sec.

Insulation/
Thickness

Overall
Diameter

Cable
Weight

Standard
Packing
Length
*

max.
(ohm/km)

min.
(Mohm.km)

max.
(A)

max.
(A)

nom.
(mm)

approx.
(mm)

approx.
(kg/km)

(meter/
packing)

39. 0
26. 0
19. 5

0.013
0.011
0.010

6
10
16

0.6
0.6
0.6

2.2
2.3
2.6

9
12
16

100/c
100/c
100/c

58
86
115

Test Voltage : 2,000 VAC/5 minutes

Rated Voltage : 450/750 V


Standard Specification : SNI 04-6629.3 : 2006 (IEC 02)
DC Resistance at

Cable Size
(No. of core
x Conductor
Area)

Conductor
Make-up
(No.of wire
x Diameter)

20C
Conductor

nom.
(mm2)

nom.
(mm)

max.
(ohm/km)

1.5
2.5
4
6
10
16
25
35
50
70
95
120
150
185
240

30
50
56
84
80
126
196
276
396
360
475
608
756
925
1221

x
x
x
x
x
x
x
x
x
x
x
x
x
x
x

0.25
0.25
0.30
0.30
0.40
0.40
0.40
0.40
0.40
0.50
0.50
0.50
0.50
0.50
0.50

13. 3
7. 98
4. 95
3. 30
1. 91
1. 21
0. 78
0. 554
0. 386
0. 272
0. 206
0. 161
0. 129
0. 106
0. 0801

70C
Insulation

Current
Carrying
Capacity in
air 30C

Short
Circuit
Current
1 Sec.

Insulation/
Thickness

Overall
Diameter

Cable
Weight

Standard
Packing
Length
*

min.
(Mohm.km)

max.
(A)

max.
(A)

nom.
(mm)

approx.
(mm)

approx.
(kg/km)

(meter/
packing)

0.010
0.009
0.007
0.006
0.0056
0.0046
0.0044
0.0038
0.0037
0.0032
0.0032
0.0029
0.0029
0.0029
0.0028

24
32
41
53
72
97
128
156
195
243
287
342
386
441
520

173
288
460
690
1,150
1,840
2,875
4,025
5,750
8,050
10,925
13,801
17,251
21,276
27,601

0.7
0.8
0.8
0.8
1.0
1.0
1.2
1.2
1.4
1.4
1.6
1.6
1.8
2.0
2.2

3.2
3.9
4.4
5.0
6.4
7.4
9.3
10.5
12.4
14.2
16.5
18.5
20.3
22.6
25.7

22
35
52
73
122
180
275
347
531
735
969
1,279
1,559
1,899
2,479

100/c
100/c
100/c
100/c
100/c
100/c
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
1,000/d
500/d
500/d

d = drum

PT KMI Wire and Cable Tbk reserves the right to change the data content without prior notification

PT KMI Wire and Cable Tbk


Jl. Raya Bekasi Km. 23,1 - Cakung, Jakarta 13910, INDONESIA
PO BOX 2468, Jakarta 10001, Phone +62-21-4601733, Fax +62-21-4601738
E-mail: domesticmarketing@kmi.co.id, overseasmarketing@kmi.co.id
Website: www.kmi.co.id

rhema

* c = coil

Rev. 4.0/22-09-2015

Test Voltage : 2,500 VAC/5 minutes