You are on page 1of 8

XT-2000i and XT-1800i

Automated Hematology Analyzers


Mid Volume Laboratory Solution
Advanced Technology Solutions
to Meet your Labs Needs
Even with these challenges, the need for hematology testing
has remained steady or continued to grow. Laboratories
are searching for hematology analyzers that can improve
productivity and eciency while providing enhanced
clinical information. Designed to be reliable and ecient,
the Sysmex XT-2000i and XT-1800i (XT) oers medium
volume labs an automated hematology system that can
truly meet and exceed their expectations. The XT streamlines
your workow by providing testing for up to 80 samples
per hour, enabling rapid turnaround time.

Todays Laboratory Fluorescent Flow Cytometry


Challenges Yields Optimized Productivity
Laboratories continue to face The Sysmex XT Automated Hematology Systems
a number of challenges. utilize the power of uorescent ow cytometry and
hydrodynamic focusing technologies. Using a unique,
diode laser bench, Sysmex uorescent ow cytometry
These include clinical, operational provides the sensitivity needed for measuring and
and nancial issues such as: dierentiating cell types in whole blood and body
uid samples. Fluorescent technology and
Demand for clinically relevant information
hydrodynamic focusing enable the analyzers to
Medical technologist labor shortage
consistently classify normal WBC, RBC, and PLT
Increased workload
populations from abnormal populations, thereby
Need for faster turnaround time
decreasing the number of manual interventions.
Requirement for high reliability
Limited laboratory budgets

1
Clinically Relevant Information

Eective Red Cell RBCs and PLTs


Disorder Screening and
Therapy Monitoring RBCs and PLTs are counted in a
dedicated channel using Impedance or
The XT-Series provide the panel Direct Current (DC) detection method
of standard parameters for basic combined with hydrodynamic focusing
and reliable anemia screening technology. Challenges to cell counting
and monitoring. such as coincidence or recirculation
are circumvented and automatic
discriminators separate the two
cell populations.
Conversion to SLS-Hgb
Even with samples at extremely
low or unusually high concentrations, High Quality Hemoglobin
the XT-Series analyze RBCs and PLTs (HGB) Analysis
with uncompromised precision
The XT utilizes the cyanide-free
and accuracy.
reagent, Sodium Laurel Sulfate
(SLS). The end product is a colored
compound that is measured
Hydrodynamic Focused Cell Counting spectrophotometrically. Since hemoglobin
determinations are performed from a
dilution and in its own separate chamber,
WBC, A Clear Dierentiation there is no interference from high WBC
counts, lipemia or abnormal proteins.
The combination of side scatter
(cell complexity), forward scatter
Direct Hematocrit (HCT)
(cell size) and uorescence (DNA &
Measurement
RNA concentration) of nucleated cells
provides a concise and precise image The cumulative pulse heights of all the
of each detected peripheral blood cell. RBC counts yield the HCT. This is based
on the principle that the pulse height
This 3-dimensional blood cell analysis
(voltage change) produced by cells
provides unique accuracy and precision.
passing through the aperture is
Fluorescence labeling of peripheral WBC Dierential Scattergram proportional to cell volume.
blood cells is a milestone for the
routine leukocyte dierential.

Fluorescent technology enables


the XT to reliably dierentiate normal
WBC populations from abnormal WBC
populations. The sensitivity of the
unique application of uorescent ow
cytometry gives the lab a high level of
condence in reporting accurate WBC
dierentials, even on critical patient
samples when the WBC count is low.

2
Advanced Clinical Parameters

Immature Granulocyte Count Fluorescent Optical Platelet Body Fluid

Immature Granulocytes Fluorescent Optical Platelet* Body Fluids


(IG) Determination
The XT-2000i oers both a The XT analyzers include measurement
Cells included in the IG count Fluorescent Optical Platelet (PLT-O) for body uids. These analyzers provide
are metamyelocytes, myelocytes, in addition to the traditional impedance reportable WBC and RBC counts
and promyelocytes PLT count. Flagging associated with for all common body uid samples
The IG parameter is provided atypical or abnormal platelets, due to (CSF, synovial and serous).
from the DIFF channel increased size or fragmentation is
The IG software applies a exible minimized by use of the optical The analyzers apply proven
gating algorithm tailored to platelet count. Accuracy in reporting impedance and uorescent ow
individual samples, thus providing is supported by the availability of both cytometry technology ensuring
reliable IG counts technologies. an accurate body uid count from
a single sample analysis.
The IG Parameter provides: Fluorescent Optical Platelet is a
complementary, reportable parameter The XT Body Fluid Count provides:
Improved accuracy and sensitivity to the impedance platelet count.
Reduced false positive and No sample pre-treatment
false negative rates The PLT-O parameter provides: No additional reagents or
Result consistency by reducing additional quality control material
Improved accuracy on low requirement
tech-to-tech variation in reporting
platelet counts An automatic background check
manual dierentials
Accurate counts when interferences prior to analyzing a sample
Improved workow are present, thus reducing manual
Fewer manual dierentials means intervention The XT Body Fluid Count benets:
faster turnaround time (TAT) Automated judgment for reporting Improved productivity
PLT-O or impedance PLT through Decreased turnaround time (TAT)
Labor savings instrument settings, eliminating Decrease manual technical
Fewer manual slide reviews improves tech-to-tech decision variability intervention
laboratory eciency and supports
higher laboratory output *XT-2000i only

3
One Comprehensive System

With the use of uorescent technology, the reticulocyte count assures:

Accurate reticulocyte % and #


Improved immature reticulocyte fraction (IRF) information for earlier diagnosis
and treatment by clinicians
Elimination of common interferences from Howell-Jolly bodies,
Pappenheimer bodies and immature reticulocytes to avoid manual counts

In addition, the Reticulocyte Hemoglobin (RET-He), is a parameter measured


in the reticulocyte channel which is used to measure the incorporation of iron
into erythrocyte hemoglobin.
Fluorescent Reticulocyte Count
The RET-He parameter supports:

Reticulocyte Analysis* Rapid, direct analysis of an earlier stage of RBC development for
prompt clinical follow-up
Known as the Gold Standard Assessment of anemia. RET-He is an established parameter used in
reticulocyte testing parameter, the KDOQI (Kidney Disease Outcomes Quality Initiative) guidelines for assessing
uorescent reticulocyte count is the initial iron status of patients
available on the XT-2000i. Sysmex Accuracy and sensitivity in measurement of red cell production that aids
was one of the rst companies to the clinician in eective monitoring of costly drug protocols for cell stimulation
provide on-board retic testing in
a dedicated channel, which improved *XT-2000i only
eciencies in reticulocyte counting.

Positive Patient
Sample with
Retic Analysis

4
Improved Productivity & Efficiency

e-Tools: Assuring Quality Remote Monitoring Sysmex WAM


and Optimizing Performance
Continuous collection and The XT can be used in conjunction
TM
SNCS , Sysmex Network monitoring of instrument performance with Sysmex WAM Decision
Communications System, is proprietary data is linked to our tracking and Support Software for the Clinical
software which enables fast, secure dispatch system. We monitor your Laboratory, which enhances sample
communication from your analyzer to instrument performance, instrument and data workow and improves
Sysmex servers using a high-speed, conguration settings and back-up turnaround time (TAT).
outbound internet connection. This settings continuously.
powerful tool is the instrument data For the Mid Volume
link feeding a variety of innovative Make your lab more ecient with: Laboratory
tools and services.
Unobtrusive, remote and The XT oers comprehensive
real-time monitoring clinical testing menus for whole
InsightTM Proactive identication and blood and body uids, providing
Insight is a web-based Interlaboratory follow-up of potential issues accurate, precise and sensitive
Quality Assessment Program (IQAP) Enhanced rst-time eld xes, results. Your clinicians receive quality
which allows on-demand quality if needed results to assist in the diagnosis,
control reporting with access anytime, management and therapeutic
anywhere. Insight meets the e-Supply Reagent monitoring of disease states.
requirements to document peer Inventory Management
comparison data for your analyzer
The e-Supply program oers online
while eliminating manual steps.
reagent monitoring that simplies
both ordering and inventory processes.

This innovative program helps you:

Track reagent usage and inventory


Maintain appropriate inventory levels
Reduce your shipping cost

5
Sysmex XT-2000i and XT-1800i
Specifications
Principles & Technologies Fluorescent Flow Cytometry:
WBC-Di
DC-Sheath-Flow:
RBC, HCT, PLT
Cyanide-free SLS-Method:
HGB

21 Whole Blood Reportable WBC, RBC, HGB, HCT, MCV, MCH, MCHC,
Parameters PLT (Impedance and Fluorescent Optical)
NEUT%, LYMPH%, MONO%, EO%, BASO%,
NEUT#, LYMPH#, MONO#, EO#, BASO#,
RDW-SD, RDW-CV, MPV

Additional Parameters
IG XT-2000i Standard
XT-1800i Optional
RET-He XT-2000i Optional

2 Body Fluid Reportable Parameters WBC-BF, RBC-BF

Linearity WBC: 0.00 440.0 x 103/L


RBC: 0.00 8.00 x 106/L
PLT: 0 5,000 x 103/L

Throughput Whole Blood: 80 samples/hour (max.)


Body Fluid: 30 samples/hour (max.)

Sample Volumes Closed Mode: 150L


Manual Mode: 85L
Capillary Mode: 40L

Data Storage 10,000 samples (including graphics)


(IPU: Information Processing Unit)

Quality Control Comprehensive QC les including


(Total QC Management) current and new lot feature
Levey-Jennings control chart
X-barM le
Online Quality Assurance
Program InsightTM

Interfaces ASTM
Sysmex WAMTM (HL7 & ASTM)

Dimensions / Weight Main unit (including sampler):


w x h x d [in] / [lbs] 20.9 x 24.8 x 28.3 / 129.8

6
Sysmex Corporation Sysmex America, Inc. Sysmex Canada, Inc. Sysmex Latin America and the Caribbean
One Nelson C. White Pkwy,
So Jos dos Pinhais

www.sysmex.co.jp www.sysmex.com/us
www.sysmex.ca www.sysmex.com.br

2012 Sysmex America, Inc.


Document Number MKT-10-1136 05/2012 1M

You might also like