You are on page 1of 10

Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

SITE SURVEY REPORT


TETRA (Repeater for Outdoor Coverage)
SWO - TETRA

Site name: Dam_Leb_RP_1

Site address: Damascus rural

Date: 21-07-2011

Participants: Name Signature

Telecom Engineer

Civil Engineer

E/M Engineer

Customer Representative

Customer Representative

Customer Representative

Other

SWO TETRA 1/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

. General Information

1. Site Info:

Building (Room) Rooftop (Room) Rooftop (Shelter)


Site type:
Building(Roof) h=4m Other (state): Mast= 3m
Greenfield (Shelter)
( for Donor) (for Servers)
Contact person for
Name: Army Telephone:
Site details:
Is a special permit
required for site Yes No
access?

Site access time: 7x24 5x8 Other (state):

Ease of vehicular Normal Difficult Very Difficult


access:
Hard-standing Gravel To be constructed

Route instructions
(if required):

Possible Donor
Qasiuon_1019 (Az=176)
sites:

Confirmed Confirmed Confirmed


LOS with the Donor
sites:
Not confirmed Not confirmed Not confirmed
Part of the Road from AlTal to AlHameh
Describe the
Service Area:
Coordinates at the
middle of the Latitude N: 3331'59.23" Longitude E: 3616'19.99" Site Altitude:1140m
Service area:
The Rx signal of Qasiuon_1019 at the Donor location is about - 58dBm with clear
line of sight

Comments:

SWO TETRA 2/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

I. Repeater Information

1. Site Infrastructure:
Existing / Required
Infrastructure:
Repeater Location Wall Metallic Fence Other

UPS Power System


Wall Metallic Fence Other
Location
Existing type of A/C
1 x 230 V + N + G , Fuse: A Solar system
supply / fuses
Grounding
Bar/Point near Existing grounding New grounding required
repeater
Is a new Mast
Yes (one for Donor & one for Server) No
required?

Mast location: Ground level for Server h=3m Rooftop level for Donor h=2m

Mast coordinates: Latitude N: 3334'2.33" Longitude E: 3615'59.08" Site Altitude: 650m

Lattice tower Rectangular tower Guyed Mast


H: W: D: H: W: D: H: W: D:
Mast type:

Bracket X 3 (one for


Monopole Facade mount
donor & two server)

Lightning
Existing Rod New Rod required
protection
Grounding
Bar/Point near the Existing grounding New grounding required
Mast
Existence of
sufficient Outdoor Yes read note below No
cable trays

- it could be replaced the cable tray from Donor to RP box by fixed the cable on
the wall (about 20m), and also it could be replaced the cable tray from RP box to
server by pass it under ground
- There are two Server antennas that means it required Splitter 2X1, but we will
Comments:
test the repeater with only one antenna to se if we achieve the objective

SWO TETRA 3/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

2. Antenna system info:


Donor Antenna:
Antenna model /
Yagi (73 12 21) / 1.5m (from rooftop)
height:
Azimuth / Tilt
orientation: 176/ 0
/ :
GSM Antenna:
Antenna location /
height (mid-point)
above ground level:
Azimuth / Tilt
orientation:
/ :
Server Antenna:

Antenna model /
Yagi_1(73 12 21)/ 2.5m Yagi_2(73 12 21)/ 2.5m
height:
Azimuth / Tilt
orientation: 38/-1 260/-1
/
Distance from the
Vertical: 3m Horizontal: 30m
Donor antenna:

SWO TETRA 4/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

3. Sketch of the Repeater Location, Mast Location and the required antenna attachments (Donor-Server):

3-1 Repeater location:

3-1 The Donor:

SWO TETRA 5/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

3-2 The Server:

3-3 Servers Orientations:

SWO TETRA 6/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

3-4 Rp Box:

The location of RP box depends on negotiation, here is one proposal candidate:

SWO TETRA 7/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

4. Layout sketch where the exact locations of the Repeater, UPS system, Main AC board, Mast, Antennas,
North direction, Cable trays, Ground Bars, etc are shown:

SWO TETRA 8/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

II. Required quantities of Installation material

Total length Donor Total length GSM Total length Server


Coaxial (Feeder) cables
antenna system antenna system antenna system
1/2 LCF 30m 25m
7/8 LCF
1 LCF
1 5/8 LCF
Total Donor antenna Total GSM antenna Total Server antenna
Hanger kit for coaxial cables
system system system
Clamps for 1/2
Clamps for 7/8
Clamps for 1
Clamps for 1 5/8

Cable trays Total length

Indoor L=3m, 200x60


Outdoor L=3m, 150x60
Electrical tube flexible
(L=25m, OD=32mm, ID=25mm)
AC power supply cable
(from main AC board to UPS
system)
Electrical conduit
(White L=2m, 40mmx40mm)

IV. Digital Photos

Photo Number Description

1 Proposed location for the Repeater installation

2 Proposed location for the UPS system installation

SWO TETRA 9/7


Prepared: Title: Project:

LAMPROS PRIFTAKIS SITE SURVEY REPORT (TETRA Repeater O.C) SWO - TETRA

Approved Checked Date Rev Reference

5/8/2008 1.1

3 Location of the Main AC board with the reserved fuses

4 Location of the Grounding Bar/points

5 Location of the Donor antenna

6 Location of the Server antenna

7 Mast photo (if exists)

8 Proposed location for the Mast installation

Horizon to the direction of the donor site from the point where the relevant donor antenna will
9
be installed
Panoramic view of the service area from the point where the relevant server antenna will be
10
installed
11 Other (state)

12 Other (state)

13 Other (state)

End of document.