You are on page 1of 1

INFORMATION CHECKLIST FOR CENRIFUGAL PUMP CURVES

Project Name: Dated:

S.No. DESCRIPTION Y/N/N REFERENCE DOCUMENT NO. REMARKS


A ( IF ANY)
1 Dutypointnotexceeding
10%up/downtheBEP
2 Dutypointnotapproaching
endofthecurve
3 Pumpshutoffheadvalue
shallbeatleast10%higher
thandutypointhead
4 Pumpshutoffheadvalue
shallbeatleast10%higher
thanstatichead
5 5%extrashallbe
consideredinpumphead
6 Pumpscombinedcurves
mustmatchdutypointand
mustbethereftojudge
(notasinglepointcurve).
7 PumpsVFDcurvesmustbe
presentedincaseofVFD
8 Incaseofsinglepump
operationandnoVFD,3
impellercurvesmustbe
presented,middleimpeller
shallbeselectedand
considered.
9 Pumpshutoffheadvalue
shallbeatleast10%higher
thandutypointhead
10 NPSHavailableshallbeat
least1.25timesNPSHreqd.
11 Motorshallbesizedaccrdg
totheendofthepump
performancecurve
12 Dutypointshallnot
approachendofthecurve
Note: Strike out that is not applicable. Legend: Y=Yes ; N=No ; NA=Not applicable