You are on page 1of 4

SGT-300 Industrial Gas Turbine

Mechanical Drive: (ISO) 8.20MW (11,000bhp)

Siemens has expanded its gas turbine portfolio with the introduction of the SGT-300
mechanical drive (SGT-300 MD). The product provides users with a highly efficient,
highly available, robust gas turbine for their mechanical drive requirements.

The twin-shaft SGT-300 MD is derived The SGT-300 MD delivers;


from the highly successful and reliable excellence in Health and Safety during
SGT-300 single-shaft machine. Many of installation, operation and maintenance
the components are common to the
high availability
two machines. This commonality in
using well proven designs
conjunction with components derived
with advanced features for ease
from other Siemens gas turbines provides
of maintenance
the SGT-300 MD with assured reliability.
including rapid core exchange
The SGT-300 MD can operate over a wide capability
load and speed range. The two-stage environmental excellence
power turbine design facilitates this high efficiency reducing fuel burn
capability. low emissions meeting stringent
The SGT-300 MD is focused on high legislation
availability. The core engine has an wide fuel flexibility
advanced modular design. Modules can simplicity
be changed easily, on site, or alternatively easy to transport
a complete core engine exchange can be simple and quick to install
carried out quickly. The core engine has low manpower requirements for
been designed to operate without any operation
major overhaul for four years.
These benefits secure the gas compressing,
The package provides for quick installation or oil pumping drive availability, minimizing
and easy maintenance being mounted the impact on the environment and
on a single underbase. providing real added value to the users
business.

Industrial Gas Turbines

Answers for energy.


SGT-300 Industrial Gas Turbine

SGT-300 MD core engine.

Technical specifications Gas turbine


Overview Package Key features
Twin-shaft, industrial Fabricated steel underbase Excellence in health and safety for
Mechanical drive: 8.20MW Integral oil tank personnel
Shaft efficiency: 34.6% Multi-point mounting High availability

Heat rate: 10,400kJ/kWh Optional 3-point mounting Environmentally friendly

Power turbine speed: Up to 12,000rpm Modular fluid systems incorporating: Simplicity in installation, operation
Lubricating oil system and maintenance
Compressor pressure ratio: 13.3:1
Gearbox-driven main pump
Exhaust gas flow: 29.0kg/s (65.5lb/s)
AC motor-driven auxiliary pump Maintenance
Exhaust temperature: 498C (925F) DC motor-driven emergency pump Key features
Typical emissions: NOx: <15ppmV Oil cooler and oil heater
and CO: <10ppmV (corrected to Focus on health and safety of
15% O2 dry) Electrically driven hydraulic maintenance personnel:
start system Internal cell maintenance platforms
Medium-calorific value fuels capability
(>32MJ/Nm3 Wobbe index) Hydrocarbon drains tank on package External access ladders and
Control system platforms
Axial compressor Siemens SIMATIC PLC-based with Internal lifting equipment
10-stage distributed control and processing
Large access doors
Variable inlet guide vanes capability installed on package
Optional Allen-Bradley system Designed in accordance with
Combustion ISO21789:2009 gas turbine
Optional off-package systems
applications safety
6 reverse-flow combustion chambers Vibration monitoring system
Core engine on-site maintenance,
Lean-burn Dry Low Emissions (DLE) or Fire and gas detection equipment module exchange or core exchange
conventional diffusion flame system
Fire suppression equipment
High-energy ignitor system
On- and off-line compressor
Turbine cleaning options available
2-stage overhung compressor turbine Combustion air inlet filtration options:
First stage air-cooled Simple static
2-stage high-efficiency power turbine Pulse cleaning
Rotor blades have interlocking HEPA
shrouds for mechanical integrity Enclosure
Painted carbon steel or
Bearings
stainless steel
Tilt-pad radial and thrust Noise level options
Standard vibration- and temperature- (85dB(A) standard)
monitoring
SGT-300 MD core engine module removal. SGT-300 MD package.

Package Customer Support


Key features Global support network of Authorized
Service Centers
Short installation time with minimized
customer interfaces Emergency service - 24/7 specialist
helpdesk
Compact package size
Full field service
Factory testing:
Full diagnostic support, remote
Core engine
monitoring
Functional test of fuel and lube oil
OEM modernizations and upgrades
modules and controls
In-house or on-site training programs
Pre-commissioning of package
Range of maintenance and service
Optional core customer-witness test
contracts available
Optional complete package test

3
Height to top of package: 9.11 m

Height: 3.89m

4 7 8

5
.90 m
e len gth: 6
p a ck a g
rbine
Gas tu
Wid
th: 2 SGT-300 - Compressor set
.85m
1 Combustion exhaust 4 Enclosure air inlet 7 Core engine
2 Combustion air inlet 5 Fire extinguishant acoustic enclosure
3 Enclosure air outlet 6 On-package controls 8 Driven compressor
SGT-300 mechanical drive performance

10 10.5

Lo
9 -5 10.0

w
) 0
(C

am
Hig
u re Installed

bie
rat

ha
pe Rating 8.2MW*

nt
te m

m
8 et 10500 9.5

bie

PT
e inl 15

nt

No
gin
En

PT

zzl
30

e
No
10750

zzl
7 9.0

e
Power output at turbine coupling, MW
Power output at turbine coupling, MW

40
11000

6 8.5
11500

12000
5 8.0
Nominal power turbine speed

13000
4 7.5

3 7.0

16000
Specific heat input (kJ/kWh)
2 6.5
20000

25000
1 6.0

0 5.5
6000 7000 8000 9000 10000 11000 12000 -40 -20 0 20 40 60
Power turbine speed, rpm Engine inlet temperature, C

Nominal performance Power output at turbine coupling and


Power and specific heat input and speed engine inlet temperature

SGT-300 Mechanical drive performance

Conditions / assumptions
Direct drive - no output gearbox. Natural gas fuel.
Altitude: Sea level Ambient pressure: 101.3kPa
*Inlet and exhaust ducting losses Relative humidity: 60%
have not been debited. No CO turndown in operation.

Specific heat input is drawn for an engine inlet temperature of 15C but is
approximately correct for other temperatures and is based on the LCV of the fuel.

Published by and copyright 2012: Siemens Energy, Inc. For more information, please contact All rights reserved. Trademarks mentioned in
Siemens AG 10730 Telge Road our Customer Support Center. this document are the property of Siemens AG,
Energy Sector Houston, Texas 77095, USA Tel: +49 180 524 70 00 its affiliates, or their respective owners.
Freyeslebenstrasse 1 Fax: +49 180 524 24 71
91058 Erlangen, Germany Siemens Industrial Turbomachinery Ltd (Charges depending on provider) Subject to change without prior notice. The information
P.O. Box 1, Waterside South E-mail: support.energy@siemens.com in this document contains general descriptions of the
Siemens AG Lincoln LN5 7FD, United Kingdom technical options available, which may not apply in all
Energy Sector Oil & Gas Division cases. The required technical options should therefore
Oil & Gas Division be specified in the contract.
Wolfgang-Reuter-Platz
47053 Duisburg, Germany
5

www.siemens.com/energy