Professional Documents
Culture Documents
Lecture - 1: The Contents of This Lecture Are As Follows
Lecture - 1: The Contents of This Lecture Are As Follows
1.0 INTRODUCTION
REFERENCES
Page 1 of 12
1.0 INTRODUCTION
You might have experienced that in rainy season, clothes take longer time to dry
compared to summer days or even moderate winter season. Do you find any
reason behind such phenomenon? If we ask this question to a lay man, he may say
that, it is because of higher temperature during summer. But, what about the
moderate winter days when temperature is lower compared to rainy season? Let
me tell you that this phenomenon is governed by psychrometric properties of air. In
psychrometry, we learn about the thermodynamic behavior of air-water vapour
mixture. In rainy season, air has relatively more water vapour content (air has
more relative humidity) compared to those of summer days or moderate winter.
Thus, it is the water-vapour content of air (relative humidity) in combination with
temperature which decides the time required for drying of clothes. Again, one may
ask that, how can we say that air has more water vapour (relative humidity) during
rainy season? Obviously we have many apparatus using which we can say about
the water-vapor content of the air. But, to prove this, let us take example from day
to day life. There are many substances around us which has the property of
absorbing water content from atmosphere. One such substance is table saltused
in our home for cooking purpose. You might have noticed that table salt become
wet during rainy season if kept open to atmosphere. While it does not happen in
summer days or moderate winter days because air has less water-vapour content.
Page 2 of 12
2.0 VARIOUS TERMINOLOGIES USED IN PSYCHROMETRY
Daltons law states that the total pressure exerted by a gaseous mixture is equal to
the sum of the partial pressures exerted by the constituent gases of the mixture.
Atmospheric air can be taken as mixture of dry air and water vapour. Thus, the
total atmospheric pressure at a place can be written as:
= + ..(1)
Where,
Hence, vapour pressure is defined as the partial pressure of water vapour present
in a certain volume of air. It can be calculated using the following equation.
= 0.000644 ( ) (2)
Where,
Page 3 of 12
2.2 Saturation Vapour Pressure (SVP)
At a specific or particular temperature, the air can hold a certain maximum amount
of water vapour. Further, addition of water vapour in the air will lead to
condensation of water vapour. In this situation, air is said to be fully saturated at
the specific temperature. We are talking of specific temperature, because air
holding capacity of water vapour is temperature dependent. We know that if more
molecules of a gas are present, it will exerts higher pressure in the surrounding.
Hence, the partial pressure due to water vapour will be maximum at a temperature
when air will be in saturation. The SVP at a temperature can be calculated using the
following formula.
17.27
= 610.6 ( )Pa (3)
237.3+
Where,
t = temperature (C)
At this point let me tell you that SVP is independent of pressure but SVP increases
with increase in temperature. This is because water-vapour holding capacity of air
increases with increase in temperature.
PV = mRT
Where,
P = pressure (Pa)
V= volume (m3)
Page 4 of 12
m = mass of the gas (kg)
R= gas constant(J/kgK)
T= temperature (K)
Suppose, we have a mixture of dry air and water-vapour. Let the amount of water
vapour per kg of dry air be X kg. In other words, let the specific humidity of the
moist air be X kg/kg of dry air. Let pressure due to dry air be Pd(Pa) and due to
vapour be e (Pa). Also, let total pressure due to the moist air will be P (Pa). Using
Daltons law we can write P as the sum of the individual pressures.
P = Pd + e
We can write individual pressure due to dry air and water vapour in the form of
ideal gas equation.
where,
and
where,
It should be kept in mind that, masses of the individual gases are different but,
they occupy the same volume. Total mass of moist air is m+mX (kg). Therefore,
the pressure due to moist air can be written as
+ = + = (1 + )
Where,
Page 5 of 12
+
= /() ..(4)
1+
Equation (4) indicates that for moist air, gas constant is the sum of gas constants
of dry air and water vapour in proportion to their relative masses in the moist air.
This is true for any homogeneous mixture of gases.
Like gas constant of moist air, we can apply the same formula (Eqn. 4), for
evaluating the specific heat of moist air. In other words, we can write the specific
heat of moist air as the sum of the specific heat of dry air and specific heat of water
vapour in proportion to their relative masses in the moist air.
We know that, for gases two types of specific heat exist- specific heat at constant
pressure and specific heat at constant volume. The expressions for two types of
specific heats of moist air are given below.
where,
where,
Page 6 of 12
Cvv = specific heat of water vapour at constant volume (J/(kg K))
You might have experienced that steam is more dangerous than boiling water,
though both are at 100C. Can you find any reason behind this phenomenon? Isnt
it surprising that they are at same temperature but their effect is different.
Temperature is associated with degree of hotness and not the heat content. Steam
at 100C has more heat content than boiling water at 100C. This difference in the
heat content is due to latent heat. Latent heat is defined as the heat energy that
has to be supplied or removed in order to change the state of the substance
without having any effect on its temperature. Similarly, 2260 kJ of heat per kg of
water has to be added as latent heat to boiling water for its conversion to water
vapour. Latent heat is usually expressed in kJ/kg.
Depending upon the change in state which a substance undergoes, different names
have been given to this latent heat. They are as given in Table 1.
Note:
Page 7 of 12
equal in general, but they are not the same. The reason is that, they change to
some extent by temperature or pressure. They are not constant for a particular
substance also. For example, the latent heat of condensation of water vapour is
2260 kJ/kg at 100C, but it is equal to 2460 kJ/kg at normal air temperature. You
might be surprised by this example, especially when we talk of latent heat of
condensation at normal temperature. Evaporation of water takes place at all
temperatures. Similarly, condensation may also take place at all temperatures.
The higher is the initial temperature of the liquid, the lesser is latent heat required
to evaporate it. For water, latent heat of evaporation is linearly related to
temperature by the equation:
Where,
t = temperature (C)
The word sensible itself suggest that, it is the heat which can be sensed. As
opposed to latent heat, it is the heat responsible for changing the temperature of a
substance. Change in temperature can be sensed/perceived and hence it got the
name as sensible heat.
Let us take an example where we have a mixture of dry air and water vapour. Let
its specific humidity be X kg/kg dry air. Let the mass of dry air in the mixture be m
kg. Then, mass of water vapour is mX kg. Assume that the temperature of moist air
is . Let us assume that at 0C, the water vapour content of the mixture is in
liquid phase. Our interest is to calculate heat to be added to dry air and water
(liquid) so as to heat them up to . It is easy to calculate heat added separately
to dry air and water.
For air, we can heat it directly to .
Page 8 of 12
Therefore
=
Cpd in the above equation is the specific heat of dry air (J/kgC)
For water, it involves change of state. One of the way is to heat water is shown in
Fig. 1
= ( )
= ( )
Page 9 of 12
Thus , the total heat required to heat the mixture upto taking 0 as the datum
line is given by
( + + + )
= = + + + ( )
This is called the total heat of moist air taking 0 as the datum.
Sigma heat, S is given by total heat of moist air less the heat of the liquid.
Numerically it is given by
= + = + 1005
PV = mRT
Hence, for humid air if we substitute the value of gas constant in the above
equation, it results in
(1+)
= ( + )
kg moist air/m3
We know that for any gas, at constant temperature, volume and pressure
1 1
Gas constant
18
Therefore,
=
= 28.97
= 0.622
Page 10 of 12
Substituting for X and Rv, we have
(+ 0.622 )
() ( 0.378)
= = +0.622 =
(
)
()
( 0.378)
= /3
287.04
We can also find apparent density of moist air in terms of dry air, given by
( )
= /3
287.04
Some of the constants to be used in solving numerical problems are listed in Table
2.
REFERENCES
Le Roux, W. L. (1972); Mine Ventilation Notes for Beginners; The Mine Ventilation
Society of South Africa.
Page 11 of 12
McPherson, M. J. (1993); Subsurface Ventilation and Environmental Engineering;
Chapman & Hall, London.
Misra G.B. (1986); Mine Environment and Ventilation; Oxford University Press,
Calcutta, India.
Page 12 of 12