You are on page 1of 9

Intelligence and flexibility to

solve your toughest challenges

Okken intelligent switchboard solutions


for power distribution and motor control

schneider-electric.com/okken
2 schneider-electric.com/okken schneider-electric.com/okken 3

Okken: intelligent
switchboard solutions
With safety and reliability within reach, why settle for less?

15%
Embodying decades of expertise, Okken solutions are complete and customized low-voltage
TM

(LV) power distribution, motor control, and integrated power control centres. Okken switchboards
answer the need for superior operational safety in todays high-performance LV power
applications. Versatile and durable, Okken switchboards have the comprehensive capabilities Okken solutions can provide
and intelligence you need to keep your business competitive. up to 15% energy savings.*

Industry-leading features, design, and support make implementation and operation quicker,
easier, and more reliable, so you can lower costs and realize a faster return on investment.

Okken solutions combine best-in-class safety and reliability with an optimized footprint, modular
architecture, and smart devices.

A global player with local capabilities


120k
More than 120,000 cubicles
Schneider Electric is present in more than 100 countries, delivering reliable products and solutions installed. Customers
around the world. Our global reach helps us ensure high quality and local project and service worldwide trust Okken LV
capabilities, no matter your location. switchboard solutions.

Smart grid ready


Our broad expertise in electrical network management makes us a partner who knows
what the smart grid means for your business, and how best to keep you at the forefront
of technology.

*Based on previous data, 2015. This is not a guarantee of future performance or performance in your particular circumstances.
4 schneider-electric.com/okken schneider-electric.com/okken 5

Total electrical safety


for personnel
Tested and certified by independent Three safe, interlocked drawer positions and drawer stop
ASEFA and LOVAG labs.

Connected position

Note: In working environment, full operator safety measures


should always be adopted.

Test position
With Okken, protection is never left to chance Superior internal arc withstand and
short-circuit protection
With high modularity and total insulation, safety is engineered into every Okken
switchboard. From conception, through design, installation, and everyday Fully type tested in compliance with
operation, you can count on our commitment to maximizing safety. IEC TR 61641
Internal arc withstand up to 100 kA/0.5 s
Smart engineering and user-friendly operation Arc-free zone with encapsulated active parts
in the whole switchboard: incomer, horizontal
Full type tests as per IEC 61439-1&2 confirm top-level electrical installation
busbar, withdrawable cubicle
and operational safety. Insulation and provided screening of all live parts
Active optical arc-flash detection with
enhance service life and provide outstanding protection.
VAMP system
Forms of internal separation up to 4b Maximized operator protection at three levels:
Embedded interlock systems to prevent on-load disconnection Horizontal and vertical busbars Disconnected position
Safe live-part protection up to IPxxD Functional units on all three positions of
Fully insulated busbars withdrawable drawers
Padlockable with three different locks Outgoing cable connections
Protection with optional doors and accessories Internal arc risk reduction thanks to our unique
Closed door operation for extra operator protection in all drawer positions, Polyfast system
TM

particularly in case of internal short-circuit or arc fault, and even during Partitioned terminals for electrical insulation
connecting and disconnecting between the upstream circuit breaker and the
double contact clamps on the main busbar
Rated conditional short-circuit current (Isc)
up to 150 kA
6 schneider-electric.com/okken schneider-electric.com/okken 7

Superiorreliabilityandcontinuityof service

Outstanding safety and An install-and-forget level of dependability Tough enough for Oil & Gas applications
customized solutions
for any application and The Okken design is based on a robust and Okken switchboards are DEP Shell approved
severe environment. type-tested architecture, standardized modules, for demanding needs of Oil & Gas facilities
and Schneider Electric devices. This guarantees Total , Chevron , British Petroleum , Air
TM TM TM

functionality, safety, continuity of supply, and Liquide , and others place their trust in Okken
TM

installation reliability, even in the most intelligent switchboard solutions


difficult environments.
Optimized for marine installations
All components and devices are designed
by Schneider Electric and manufactured to Okken switchboards satisfy the requirements Oil & Gas Offshore Platforms
rigorous quality standards of marine, offshore, and floating production
Tested and validated compatibility between storage and offloading applications
switchboards, functional units, and They are DNV (Det Norske Veritas) and RINA
built-in devices (Registro Italiano Navale Group) certified for
Outstanding electrical and mechanical high vibration and saline environments
consistency and electromagnetic compatibility
(EMC) of all Schneider Electric components
TM

Durability for seismic areas


Okken 2.7G and 5G ensure excellent
Resistance to corrosive environments
mechanical resistance and secure installation
Tin, nickel, or silver busbar coating on in seismic zones in compliance with the most
Mining, Metals, Minerals Marine
copper conductive parts for H2S and SO2 demanding local and international standards:
atmosphere withstand IBC 2006/AC 156, IEC68-3-3, AS1170,
Anticorrosion surface treatments on EAK-2000, ENDESA-1986, GOST 17516.1-90,
metallic sheets IEEE 693-1997, EDF CRT 91 C 112 00
(on Okken 5G)
O
 kken switchboards provide a variety of
protection levels (up to IP54) 5G versions are specifically engineered for
high-safety nuclear and industrial applications

Thermal monitoring
Permanent temperature monitoring with
sensors on critical parts (Exertherm system)
Nuclear Water and Wastewater Treatment
Predictive maintenance to increase prevention
and safety level of your switchboard

Healthcare Data Centres


8 schneider-electric.com/okken schneider-electric.com/okken 9

High performance and


superior efficiency
Compact, modular Industry-leading capabilities
design the right fit for
your organization Maximum busbar rating up to 7300 A Electrical distribution
Maximum rating of Power Control Centre (PCC), up to 6300 A up to 7300 A
Maximum rating of Motor Control Centre (MCC), up to 250 kW Incomer and feeder
Smart communicating devices for connected switchboards up to 6300 A
Compact design for higher stacking density and optimized footprint Motor control
Safe upgrading of energized equipment up to 250 kW

A disconnectable design for power distribution


The high-security power distribution switchboard offers maximum reinforced
electrical isolation thanks to the Polyfast system.

Power distribution
PCC including protection and power factor correction:

Main busbar up to 7300 A


Incomers up to 6300 A (Masterpact circuit breakers)
TM

Feeders up to 6300 A (Masterpact circuit breakers), and up to 630 A


(Compact circuit breakers)
TM

Power factor correction up to 540 kVAR

A flexible, withdrawable design for motor control and power distribution


Compact and powerful Okken switchboards answer the needs of the most
demanding motor control and power distribution applications. They combine
outstanding continuity of supply and safety with long, reliable service.

Motor control
MCC including protection, starters, and drives:

Conventional starters up to 250 kW


Soft starters up to 250 kW
Drives up to 160 kW

Note: In working environment, full operator safety


measures should always be adopted.
10 schneider-electric.com/okken schneider-electric.com/okken 11

Improved versatility
and flexibility
24/7 visibility of energy use and Smart devices to improve productivity and energy efficiency
power quality All our stand-alone devices and fully integrated solutions for energy monitoring, motor control,
and power factor correction provide advanced technology and outstanding capabilities.

Power circuit
Motor motion control
protection and control
Altivar ATV630,
TM
Energy server Coupler control
Masterpact MTZ-NT-NW,
ATV31, ATV61, ATV71, ComX 200 Sepam TM

Compact NS and NSX


Altistart ATS48
TM

up to 690 V

Motor protection
Process automation Energy and power
and monitoring
Quantum, Premium, quality metering
TeSys T, TeSys U,
TM

M340 and M580 PowerLogic PM 800


TM

TeSys D

A compact and modular design for every function Upgrade Okken while under load in
complete safety
Okken is a simple and modular solution that is easy to choose, intuitive to use,
cost effective, and simple to install or upgrade.  asily modify and upgrade your Okken solution
E
and add new functions as your needs change:
Fast, easy installation, upgrading, and maintenance scalability while under load, equipping of
additional slots in reserved spaces, association
Single front or double front access thanks to back-to-back configuration, top of cubicles, fast interchangeability without
or bottom direct power connections, rear or side power connections for easy special tools.
installation. Plus, standardized dimensions and an optimized footprint save time D
 egree of protection up to IPxxD on busbar
and money during installation. with automatic shutters, and on connections Double front access Plug-in distribution feeders on Polyfast system

Fixed, disconnectable, or withdrawable functional units on busbar by plug-in clamps

Withdrawable drawer size optimization: full and half-widths, different C


 ustomer connection separate from the
heights from 100 to 600 mm functional unit (form up to 4b)

Direct power plug connection to the vertical busbar (50 mm pitch)


Reliable drawer position indicators on front faces and drawer stop
Withdrawable Masterpact and plug-in
Compact circuit breaker modules
Current transformers inside

Comprehensive range of full and half-width drawers Direct connection to the arc-free vertical busbars
12 schneider-electric.com/okken schneider-electric.com/okken 13

iPMCC by Okken: A complete range to match your toughest needs


built-in intelligence For power distribution and motor control including variable speed drives,
motor starters, power factor correction, and harmonic filtering
Our best-in-class digital solution for
power distribution, motor control, and
power factor correction.
Greater reliability,

PCC/MCC
PCC
superior efficiency, and
enhanced productivity 230
115-70
Very high-power incomers
Mixed incomers and feeders
and feeders up to 6300 A

15% 115
Up to 15% increase 70-M**
in productivity.* High-power incomers and
Withdrawable feeders
feeders up to 4000 A

MCC and PCC


The intelligent Power and Motor Control Centre (iPMCC) by Okken is a Enhanced control and monitoring
70% Single Masterpact MTZ-NW
Single incomer or feeder
70-2
Polyfast plug-in feeders
Up to 70% reduction in (width 650 mm)
highly capable and advanced smart solution for fault prevention, protection,
Better traceability and control untimely shutdowns.*
and automatic restart in continuous and critical processes. It helps you
boost productivity and optimize the energy management and efficiency of Local or remote real-time information access
your assets while maximizing safety, enhancing continuity of service, and Motor operating status and time monitoring
Single Masterpact MTZ-NT-NS VSD 3

90%
reducing downtime. (alarms and tripping)

2
MCC
Single incomer or feeder Variable speed drives and
Parameter monitoring and management of
(width 450 mm) soft starters
Energy savings up to 15%* status, measurements, diagnostics, trends,
and energy consumption Up to 90% fewer motor
Integration of all your equipment to lower electrical energy consumption
burn-outs.*
Synchronizing motors to loads with progressive starters and variable Smart-grid integration
speed drives and reducing peak consumption by 50% or more*

4
70-F PFC 4

PFC
Reliable, highly dependable, and pretested
Managing reactive power compensation (capacitors) and thermal Fixed feeders Capacitors

50%
communication architectures offering leading
withstand control to reduce costs and increase energy availability
industry protocols engineered to optimize
asset energy efficiency (Ethernet TCP/IP,
Optimized motor performance
Ethernet/IP, Profibus -DP, DeviceNet , Modbus,
TM
1
PCC = Power Control Centre
CANopen , etc.) Up to 50% reduction in
Motor monitoring and protection with failure activities in accordance with

2
MCC = Motor Control Centre
maintenance costs.* 185
IEC/EN 60947-7-1 Seamless integration with energy management 3
VSD = Variable Speed Drive

Motor and protection device configuration accessible at all times and control systems and process automation Fixed feeders
4
PFC = Power Factor Correction and harmonic filtering

Associated with TeSys T, iPMCC by Okken enables the detection of faults management systems ** F
 or specific applications (marine, seismic, nuclear, etc.),
please contact Schneider Electric.
like no-load running, shaft bearing seizure, abnormal starting or heating, Complete range of design assistance tools
pump cavitations, and pulsating torque

* Based on previous data, 2015. This is not a guarantee of future performance or performance in your particular circumstances.
14 schneider-electric.com/okken schneider-electric.com/okken 15

Okken intelligent
switchboard specifications
Dedicated support for complete peace of mind
General data
Around the world, the acknowledged leadership of Schneider Electric in energy
Applications Power distribution, motor control
management and power protection means you can count on us to deliver the
MCC (Motor Control Centre) up to 250 kW products, services, and support you need to be most efficient.
VSD (Variable Speed Drive) up to 160 kW
Our highly skilled service and support professionals are there to provide
PCC (Power Control Centre) incomer & feeder up to 6300 A business-aligned results for a measurable return on your investment.
PFC (Power Factor Correction) up to 6* 90 kVAR
Standards IEC 61439-1 & 2, IEC TR 61641, IEC 60529 Tools and support services
Certifications EAC (Gost), CCC, AS Validated tools and architectures
Electrical data Regional and local services for the installed base, plus assistance
and troubleshooting
Voltage up to 690 Vac (50/60 Hz)
Customized vocational training on-site or in one of our training centres
Main busbar rating up to 7300 A
Distribution busbar rating up to 2100 A Auditing, consulting, and solution engineering
Rated short-time current (lcw) Customized projects, including critical applications
horizontal main busbar up to 150 kA rms - 1s (peak current lpk up to 330 kA) Engineering expertise for new and existing sites
vertical distribution busbar up to 100 kA rms - 1s (peak current lpk up to 220 kA) Installation and energy audits

Conditional short-circuit current (lsc) up to 150 kA Enterprisewide energy efficiency solutions

Internal arc withstand current 100 kA 0.5 s (IEC TR 61641) The Okken panelbuilder network guarantees optimum localized service
Earthing system TT-IT-TNS-TNC O
 kken can be supplied by the Schneider Electric equipment units or by
Communication licensed partner panelbuilders present around the world
These partners, selected for their expertise, are trained and regularly audited
Protocols Ethernet TCP/IP, Ethernet/IP, Profibus-DP, DeviceNet, Modbus, by Schneider Electric to guarantee top-quality equipment and support
CANopen, etc.

Mechanical data
Form 2b/3b/4a/4b
Withdrawability FFF/WFD/WFW/WWW
Green Premium equipment
TM

Seismic withstand IBC 2006/AC 156 (site class B-C-D, floor level only), IEC68-3-3 (equivalent to
Richter scale up to level 9), AS1170, EAK-2000, ENDESA-1986, GOST 17516.1-90
(civil market, all seismic intensity, up to installation level 2), IEEE 693-1997, EDF Ecologically designed and manufactured without hazardous materials
CRT 91 C 112 00 (Okken 5G only for nuclear applications) Compliant with RoHS and REACh standards
Installation indoor environment type 2 Designed for reduced carbon footprint and energy consumption
Degree of protection IP20, IP31, IP41, IP54 Designed for optimal recycling and end-of-life management
Operating temperature - 5 C to 35 C/50 C
Schneider Electric Industries SAS

Head Office
35 rue Joseph Monier
92500 Rueil Malmaison Cedex- France
Tel.: +33 (0)1 41 29 70 00

www.schneider-electric.com

2016 Schneider Electric. All Rights Reserved.


Schneider Electric | Life Is On, Masterpact, Compact, Altivar, Altistart, Sepam, TeSys, and