You are on page 1of 2
CONTEC TLC9803 Dynamic ECG Systems Brief Introduction ‘TLC9803 Dynamic ECG Systems adapts 3-lead systems defined by our company, can record continuously ECG waves for 24h, and analyses waves with PC software. It is applicable in hospital and community medical establishment. CONTEC’ TLC9803 Recorder Features ‘With advanced design and technology the recorder can work stably, dependably and durably 1 Be provided with the capability of antjamming and aseemati ‘Smal volume with OLED seren, The resolution is 160128. 1 Be provided with functions of waveform preview, record review and event marking 1 Accurate record ofthe start time of the data sampled oning to the realtime clock of isl. 1» Avoid damage owing tothe repeating inserting and puling out by using the inbuilt TF card to storage the data, ‘©The maximum capably can be 268, 50 the original data can be saved perfectly by no compression 1 The average review time of single case canbe less than 40 seconds by using interface of USB 20. 1 Record waveform detallsinextens bythe desig of high precision and sampling fequency. 1 Record the state of pacemaker exactly by higher sampling equency The Features of Software ‘= Quick and accurate analysis system. 1 The 3 ead syncvo analysis, to in acurate, QRS search canbe acutte and no dstotion. 1 There are more than 10 templates a aia premature best module, vntriular premature best module, long interval mele, til fue module ail rilation module ee. nd mulipliate User-defined templates could lost identity every kindof pathologic waveforms. 1 Flexible analysis channe selection function, can chose any chanel a the mainly analysis the channel 1 Fee tial fibration analysis, so that physicians can Use fl segmented automatic, manual analysis of ial ‘brillation, make the anaiysis mere ui and accurately ‘= Powerful pacemaker analysis, on the AAI, VVI, DDD etc. all pacemaker analysis. 1 Many pacine modules have been added 1 Fost review ana function, canbe any period of time the review single lad oral leads elecrocardiogram 1 Analysis of heart rate variably with short ange 5 minutes and lng range 1 hour and 26 hour analysis of hear tate variably. «© One-stop printing operation, report printing proces is convenient and quick 1 Perec funtion of case management 1 Advanced ST segment analysis and myocardial ischemia ttl load can forthe ST abnormal nays according to the whole and event, make the doctor can comprehensive judgment myocardial ischemia. 1 Unique “seep breath pause syndrome analyse analysis can predict Slep breath pause isk 1 "HRT analysis an predic the sk of death in paents with myocar infrton ‘Wave alleraton’ analysis an important index to predict malignant arthythmia and sudden cardiac death Standard ‘+ Number of channels 3 channels Sampling acuracy28%t s Record time: 24h Power: 2 AA size batteries a Interface: USB20 Scale voltage: ImV25% 1 Standard Sensitivity: 10mnvinVs5% «Noise level: <30hV peteemeel Accessories 1 Low-frequency characteristics: Time constant>3.2s 1 Scan speed: 25mm/s25% 1 Enduring polarization voltage: £300m DC polarization voltage sensitivity shift<210% 1 Least measure signal: 50 nV p-p 1 Product safety type: Type 6 Intemaly powered) Physical Characteristic XX lor: 1214) 6000 X 2514) mm GZ ‘Contac Mescal Systems Co. sop rots err st aren end Dlg {O° Gren nts MORE” HR OFA Erol ncmenedony cneabegrelan ste hepa

You might also like