Professional Documents
Culture Documents
Perhitungan
Perhitungan
3 m
4m 0,5 m
0,7m
2 m 1m
2,5 m
0,5 m
H static = 7,5
Qsumuran 0,05m3 / dt
1. Q pompa = JumlahPompa = 1 = 0,05 m3/dt
2. Hf Mayor
a. Pipa Suction
Q 0,05
2,63
1,85 L 2,63
1,85 5,5
Hf mayor = C xD = 130 x 0.15
= 0,027 m
b. Pipa Discarge
Q 0,05
2,63
1,85 L 2,63
1,85 7,5
Hf mayor = C xD = 130 x 0.1
= 0,26 m
Jadi Hf Mayor Total = Hf May.Suction + Hf May. Discharge
= 0,027 m + 0,26 m
= 0,287 m
3. Hf Minor
Direncanakan : K Belokan = 0,3
K Gate valve = 0,085
( Kbelokan) 2 0,3
xV xV 2
Hf minor suction = 2 g = 2 (9,81) = 0,015 V2
(2 xKbelokan) Kgatevalve
xV 2
Hf minor discharge = 2g
( 2 x0,3) 0,85 2
xV
= 2 x9,81 = 0,073 V2
V2 = 2,42
4. Efisiensi Pompa () :
. Q . Hf . g
P=
. Q . Hf . g
= P
= 0,40
= 40 %