ETABS 2016 16.0.

2 License #*1XSZFCMBJUCFKGY

ETABS 2016 Shear Wall Design


IS 456:2000 Pier Design
Pier Details

Story ID Pier ID Centroid X (mm) Centroid Y (mm) Length (mm) Thickness (mm) LLRF
L2 CW1 668.2 40260.5 2667.4 250 1

Material Properties

E c (MPa) f ck (MPa) Lt.Wt Factor (Unitless) f y (MPa) f ys (MPa)


31622.78 40 1 500 415

Design Code Parameters

S C IP MAX IP MIN P MAX MinEcc Major MinEcc Minor


1.15 1.5 0.04 0.0025 0.8 Yes Yes

Pier Leg Location, Length and Thickness

Station ID Left X 1 Left Y 1 Right X 2 Right Y 2 Length Thickness


Location mm mm mm mm mm mm
Top Leg 1 668.2 38926.8 668.2 41594.2 2667.4 250
Bottom Leg 1 668.2 38926.8 668.2 41594.2 2667.4 250

Flexural Design for P u, M u2 and M u3

Station Required Required Current Flexural Pu M u2 M u3 Pier A g


Location Rebar Area (mm) Reinf Ratio Reinf Ratio Combo kN kN-m kN-m mm
Top 1667 0.0025 0.0028 UDCon50 1930 -45 -13 666851
Bottom 1667 0.0025 0.0028 UDCon50 1986 46 -518 666851

Shear Design

Station ID Rebar Shear Combo Pu Mu Vu Vc Vc+ Vs


Location mm/m kN kN-m kN kN kN
Top Leg 1 625 UDCon38 3912 -10 -150 230 712
Bottom Leg 1 625 UDCon38 4005 -518 -150 232 713

Boundary Element Check

Station ID Edge Governing Pu Mu Stress Comp Stress Limit


Location Length (mm) Combo kN kN-m MPa MPa
TopLeft Leg 1 500 UDCon9 5969 -15 9 8
TopRight Leg 1 500 UDCon9 6678 17 10.07 8
BottomLeft Leg 1 500 UDCon8 6771 -18 10.22 8
BotttomRight Leg 1 500 UDCon8 6165 442 10.74 8

170218_Tower_Typical.EDB Page 1 of 1 2/21/2017