You are on page 1of 2
ertificate of Compliance Cerificte Nurber 20080530 Issue Dale 2008 June 2 Issued to: This is to certify that representative samples of Standards) for Safety: Additional Information: Report Reference Ex6008 - March 14, 1997 Bermad Control Valves 4070 B Leaverton Ct. Anaheim, CA 92807 Valves: i See Addendum Page 1 Have been investigated by Underwriters Laboratories Inc.® in accordance with the Standard(s) indicated on this Certifieate, ‘The basic standard used to invéstigate products in this category is UL 260, "Dry Pipe and Deluge Valves for Fire-Protection Service". For operation hydraulicallyypncumatically, electrically, manually, retiotely or combinations thereof. End configurations may'be flanged, grooved or threaded, Only those products bearing the UL Listing Mark should be considered as being ‘covered by UL's Listing and Follow-Up Service, The UL Listing Mark generally includes the following elements: the symbol UL in a circle with the word “LISTED”; a control number (may be alphanumeric) assigned by UL; and the product category name (product identifier) as indicated in the appropriate UL Directory Look for the UL Listing Mark on the product Certificate of Com Certicale Number 20080530 Page 2 of 2 eportRefence Ex6008 - March 14, 1997 Issue 2008 June 2 Underwriters Addendum Page 1 Deluge valves, Model 400E, rated pressure 250 psig, flanged, grooved or threaded body end connections. 1-1/2, 2, 2-1/2, 3,4, 6 and 8 in. size globe pattern for horizontal and vertical installation and 2 in. size angle pattern for ‘vertical installation, For operation hydraulically, pneumatically, electrically, manually or combinations thereof. ‘The height of the pilot line above the valve is limited as shown in the manufacturer's installation instructions. For use with trim configurations 1, 2, 3D, 4D, 5, 5D, 6, 6D, 7 and trimconfigurations IM, 2M, 3M, 4M, 5M with EasyLock Manual Reset and Remote On-Off trim with trim configurations 3D-RI. to enable Remote Reset for De-Latching, as shown in the manufacturers installation instructions. Model 400E Water control valve with pressure regulating tri in-the 1-1/2, 2, 2-1/2, 3, 4, 6, and 8 in, size globe patter for horizontal or vertical installation, For use with trim configurations 2C, MC, 3DC, 4DC, SC, SDC, 6DC and 6C, installed in accordance with the manufacturers installation instructions, ‘The 400E valves can be equipped withthe following optional accessories: Hazardous location solenoid valves, Valve Visual Position Indicator Stem, Electric Limit Switch and Hazardous location Limit Switch, Deluge valves, Model 700E, rated pressure 300 psig, flanged grooved or threaded body end connections. 1-1/2, 2,2-1/2, 3,4, 6, 8 and 10 in size globe pattern for horizontal or vertical installation and 2,3, 4, 6, 8 and 10 in size angle patter for vertical instalation. For operation hydraulically, peumatically electrically, manually or ‘combinations thereof. The height of the pilot line above the valve is limited as shown inthe manufacturer installation instructions. For use with trim configurations 1, 2, 3D, 4D, 5, SD, 6, 6D, 7 and tim configurations IM, 2M, 3M, 4M, 5M with EasyLock Manual Reset and Remote On-Off trim with trim configurations 3D-RL to enable Remote Reset for De-Latching, as shown inthe manufacturer’ installation instructions. Mode 700E Water control valve with pressure regulating trim inthe 1-1/2, 2-1/2, 3,4, 6 8 and 10 in. size globe and Angle pattem for horizontal or vertical installation, For use with trim configurations 2C, MC, 3DC, ADC, $C, SPC, 6DC and 6C, installed in accordance with the manufacturer's installation instructions. ‘The 700E valves can be equipped with the following optional accessories: Hazardous location solenoid valves, Valve Visual Position Indicator Stem, Electric Limit Switch and Hazardous location Limit Switch.

You might also like