You are on page 1of 8

Engineered Solutions For Clean Air

Trions T Series is ideal for the removal of smoke, fumes, and


oil/coolant smoke and mist.

The T Series has the ability to clean contaminated indoor air


and recirculate it back to the work area, reducing energy costs
by not having to exhaust conditioned air to the outside. Any of
the T Series can be installed free hanging or ducted for source
capture.

Features
Solid state power supply
Spiked ionizing blades Air Boss T2002 Blowerless
Extra depth collector cells

Totally enclosed fan cooled motor How It Works


Electrical component box mounted out of air stream Trions T Series utilizes the principle of Electrostatic Precipitation.
Air is drawn by the motor/blower through a washable metal
Optional multi-purpose plenum
mesh pre-filter which traps large dust particles. The remaining
Motor HP options for added static pressure particles, some as small as 0.01 microns, pass into a strong
electrical field (ionizing section) where the particulate receives
Benefits an electrical charge. The charged particles then pass into a
Ceramic insulators out of airstream for collector plate section made up of a series of equally spaced
increased reliability parallel plates. Each alternate plate is charged with the same
polarity as the particles, which repel, while the interleaving
Extra depth collector cell more dirt holding plates are grounded, which attract and collect.
capacity and stays on line longer
Spiked ionizer no ionizing wires to replace, Dirty Air Pre-Filter Ionizer Collector Clean Air
reducing maintenance and replacement cost

High efficiency up to 95% on single pass


and 99% on double pass option

Permanent ionizer/collector elements no


filter replacement cost; just wash, dry and reinstall
Low pressure drop lower energy cost to operate
Electronic Air Cleaning
compared to media and cartridge units

Hinged access no tools required for quick


and easy service

2
1.12 DIA.
DRAIN LOCATION 6.75 T1001 BLOWERLESS
.56 23.87
.56
Dimensions 25" L x 25" W x 21" H
5.00
Installation Suspended, wall, frame or duct mounting
19.62
Unit Weight 91 lbs., Shipping Wt. 144 lbs.
18.50
24.60
Air Volume 800 - 1600 CFM

Controls On/Off switch with indicating light

Pre-Filter Aluminum mesh


.406 DIA. DIMPLE
MOUNTING HOLE
LOCATION
Standard 18.4" L x 18.4" W x .88" D
21.82
Option Impinger
ELECTRICAL
ENCLOSURE COVER
POWER SUPPLY INSIDE Primary Filter
Standard Forever Filter - Electronic Ionizer Collector Cell
TOP VIEW
Option Bag filter
Option Adsorber module

21.00
After-Filter Optional disposable charcoal after-filter (1 required)
18.4" W x 18.4" H x .88" D
17.00
Power Supply High frequency solid state design

2.00
Efficiency To 95% based on D.O.P. test method,
2.00 15.62 to 99% for Double Pass (calculated)
DISCHARGE END
General Multiple units can be joined together for
25.00
increased volume or higher efficiency

Standard Specifications for Each Unit


AIR
ELECTRICAL FLOW
Cabinet 16 gauge welded galvanized steel
JUNCTION BOX
Finish Pearl white epoxy powder coat
Air Flow Horizontal standard right to left (left to right option)
FRONT VIEW Accessories Source capture plenum (option)
5.94 3.88
Brass drain fitting (option)
.312 DIA. TYP.
24 PLCS.
1.00
Note: Units can be stacked in configurations up to 9600 cfm.

5.00
AIR TYP.
17.00 19.00
FLOW

5.50

1.00
2.00
15.62 2.00
INTAKE END

3
.56 43.88
6.75
.56 1.12 DIA.
DRAIN LOCATION
T1300
5.00
Dimensions 45" L x 25" W x 21" H
20.25 18.50
24.60 Installation Suspended, wall, frame mounting
.406 DIA.
DIMPLE
MOUNTING
Unit Weight 180 lbs., Shipping Wt. 268 lbs.
HOLE
LOCATION
Motor TEFC, sealed ball bearings, 1725 RPM, thermal
21.19 protected continuous duty, U.L. listed
ELECTRICAL
ENCLOSURE COVER
POWER SUPPLY INSI DE
Motor Options HP VAC HZ Phase Amp.Max Watts Max
ESTIMATED UNIT WE IGHT: 180 LBS.
TOP VIEW Standard 3/4 120/230 60 1 11.7/6.1 950
3.44 6.38 MULTI-DIRECTIONAL Option 1 208/230/460 60 3 3.5/1.8 900
DISCHARGE GRILLE

Blower Belt driven, squirrel cage, forward curved,


with sealed ball bearings
21.00
11.25 Air Volume 800 - 1600 CFM
6.38
Factory set at 1300 CFM
4.06
Efficiency To 95% based on D.O.P. test method,
3.31
to 99% for Double Pass (calculated)
4.19 11.25

DISCHARGE END Controls On/Off switch with indicating light


45.00
Sound Rating 67 dBA
Pre-Filter
Standard Aluminum mesh 18.4" L x 18.4" W x .88" D
AIR
FLOW Option Impinger
Primary Filter
Standard Forever Filter - Electronic Ionizer Collector Cell
BLOWER ACCESS DOOR Option Bag filter
ELECTRICAL JUNCTION BOX FRONT VIEW
3.88 Option Adsorber module
.312 DIA. 5.94
12 PLCS.
TYP.
1.00
After-Filter Disposable charcoal after-filter option
18.4" W x 18.4" H x .88" D

19.00
Power Supply High frequency solid state design

17.00 5.00
TYP. Standard Specifications for Each Unit
5.50
Cabinet 16 gauge welded galvanized steel
2.00 1.00

15.62 2.00
Finish Pearl white epoxy powder coat
INTAKE END Air Flow Horizontal standard right to left (left to right opt)
Accessories Source capture plenum; brass drain fitting;
adsorber module in lieu of Ionizer/Collector Cell;
1 and 2 HP motors

4
1.12 DIA.
DRAIN LOCATION 6.75
.56 23.87 5.00
T2002 BLOWERLESS
Dimensions 25" L x 43" W x 21" H
.56

Installation Suspended, wall, frame or duct mounting


37.75
42.72

36.63
Unit Weight 148 lbs., Shipping Wt. 221 lbs.

Air Volume 1600 - 3000 CFM

Controls On/Off switch with indicating light


.406 DIA. DIMPLE
MOUNTING HOLE Pre-Filter Aluminum mesh (2)
LOCATION
Standard 18.4" L x 18.4" W x .88" D
21.82 Option Impinger (2)
ELECTRICAL ENCLOSURE COVER
POWER SUPPLY INSIDE Primary Filter
ESTIMATED UNIT WEIGHT: 148 LBS. Standard Optional Forever Filter - Electronic
TOP VIEW
Ionizer/Collector Cell (2 required)
Option Bag filter (2 required)
Option Adsorber module (2 required)
21.00 17.00

After-Filter Optional disposable charcoal after-filter


(2 required)
2.00
2.00 33.75 18.4" W x 18.4" H x .88" D
DISCHARGE END
Power Supply High frequency solid state design
25.00

Efficiency To 95% based on D.O.P. test method,


to 99% for Double Pass (calculated)

General Multiple units can be joined together for


ELECTRICAL
JUNCTION BOX
increased volume or higher efficiency
FRONT VIEW
7.50
Standard Specifications for Each Unit
3.87
.312 DIA. TYP.
32 PLCS. 1.00
Cabinet 16 gauge welded galvanized steel
Finish Pearl white epoxy powder coat
5.00
TYP.
17.00 19.00
Air Flow Horizontal standard right to left (left to right opt)
Accessories Source capture plenum (option)
Brass drain fitting (option)
1.00 5.50
2.00
33.75 2.00 Note: Units can be stacked in configurations up to 19200 cfm.
INTAKE END

5
.56 43.88

.56 1.12 (28) DIA.


DRAIN LOCATION
6.75 5.00
T2600
Dimensions 45" L x 43" W x 21" H
Installation Suspended, wall or frame mounting
Unit Weight 257 lbs., Shipping Wt. 363 lbs.
36.63
38.37
42.72 Motor TEFC, sealed ball bearings, 1725 RPM, thermal
protected continuous duty, U.L. listed
Motor Options HP VAC HZ Phase Amp.Max
Standard 3/4 120/230 60 1 7
Option 1 1 208/230/460 60 3 3.4/1.7

21.19
Option 2 2 208/230/460 60 3 6.4/3.2

.406 DIA. DIMPLE


MOUNTING HOLE
Blower Belt driven, double squirrel cage, forward curved,
LOCATION
with sealed ball bearings
ELECTRICAL ENCLOSURE COVER
ESTIMATED UNIT WEIGHT: 257 LBS. TOP VIEW POWER SUPPLY INSIDE
Air Volume 1600 - 3200 CFM
6.38 Factory set at 2600 CFM
4.94 15.13 MULTI-DIRECTIONAL DISCHARGE GRILLE
Efficiency To 95% based on D.O.P. test method,
to 99% for Double Pass (calculated)
21.00 Controls On/Off switch with indicating light
11.25
6.38
Sound Rating 71 dBA
4.06

3.31 3.88
Pre-Filter
5.69 11.25 11.25
Standard Aluminum mesh: 18.4" L x 18.4" W x .88" D (2 req.)
DISCHARGE END Option Impingers (2 required)
45.00 Primary Filter
BLOWER ACCESS DOOR Standard Forever Filter-Electronic Ionizer/Collector Cell (2 req.)
AIR
Option Bag filters (2 required)
ELECTRICAL JUNCTION BOX FLOW
Option Adsorber modules (2 required)
After-Filter Optional disposable charcoal after-filter (2 required)
18.4" W x 18.4" H x 1" D
FRONT VIEW
.312 DIA.
16 PLCS.
7.50 3.87 1.00 Power Supply High frequency solid state design
TYP.

5.00
Standard Specifications for Each Unit
TYP.
19.00
17.00
Cabinet 16 gauge welded galvanized steel
Finish Pearl white epoxy powder coat
1.00 5.50
2.00
Air Flow Horizontal standard right to left (left to right opt.)
33.75 2.00

INTAKE END Accessories Source capture plenum; brass drain fitting

6
21.13
ESTIMATED UNIT WEIGHT: 750 LBS.
6.75
T5200
28.13
Dimensions 51" L x 41" W x 42" H
5.00
Installation Suspended, wall or frame mounting
AIR FLOW
(STD.)
Unit Weight 600 lbs., Shipping Wt. 730 lbs.
36.63
ELECTRICAL
CONNECTION DRAIN HOLE
Motor TEFC, sealed ball bearings, 1725 RPM, thermal
01.13
protected continuous duty, U.L. recognized

3.02 4.94
Motor Options HP VAC HZ Phase Amp.Max Watts.Max

25.72
22.90 Standard 2 120/460 60 3 6.8/3.4 1564
Option 1 3 230/460 60 3 9.7/4.0 2937
Option 2 5 230/460 60 3 14.7/7.2 4687
TOP VIEW

9.34 19.06 Blower Belt driven squirrel cage forward curved


with sealed ball bearings
Air Volume 4000-6000 CFM
Factory set at 5200 CFM
41.50

16.06
Efficiency To 95% based on D.O.P. test method, to 99% for
5.88 Double Pass (calculated)
5.47
Controls On/Off switch with indicating light motor starter
6.88
4.69
8.56 Sound Rating 76 dBA
DISCHARGE END
Pre-Filter
51.00
CONTROL SWITCH INDICATOR LIGHTS
Standard Aluminum mesh (4)
Option 18.4" L x 18.4" W x .88" D Impingers (4 required)
COMPONENT
BOX DOOR
Primary Filter
ON

OFF

AIR FLOW Standard Forever Filter- Electronic Ionizer


(STD.)
Collector Cell (4 required)
CELL DOOR
BLOWER
ACCESS COVER Option Bag filters (4 required)
(GRILL LOCATION FOR
SIDE DISCHARGE UNIT) Option Adsorber modules (4 required)
FRONT VIEW Option Disposable charcoal filter
40.62 2.25 18.4" L x 18.4" W x .88" D (4 required)
Power Supply High frequency solid state design (2 required)
17.13

37.00
Standard Specifications for Each Unit
2.75
Cabinet 16 gauge welded galvanized steel
Finish Pearl white epoxy powder coat
1.50 2.00
37.75 Air Flow Horizontal standard right to left (left to right opt)
INTAKE END
Accessories Source capture plenum; brass drain fitting

7
T1300 T2600 T5200
4.0 3.0 5.0
225

14

15
18

0
0RP

0R

0R
M 00

PM
PM
RP

2H
M

11
20 (MA
00

P
(M

/2 H
RP X. RP AX

13
M M) 16 (M .R

0
00 PM

0R
AX

P
RP )

PM
. RP

11
M M) 4.0

/2
3.0

HP

1H
18

12
00

1H

0
P

0R
RP
ADDED STATIC PRESSURE (in. H20)

ADDED STATIC PRESSURE (in. H20)

5H
P
M

PM
3/4

P
16 2.0
00
HP

ADDED STATIC PRESSURE (in. H20)


RP

110
M 14

3/

0R
00

4H

3H
RP 3.0

P M
P
M

P
2.0

10
0 0R
14
00

PM
RP 12
M 00
RP 90

2H
M 0R

P
PM
120 2.0
0RP 1.0
M 80
0R
100 PM
1.0 0RP
M
100
0RP 800 70
0R
M RPM PM
800R 60
PM 1.0 0R
PM

0 0
0 500 1000 1500 0 1000 2000 3000
CFM CFM 0

1000

2000

3000

4000

5000

6000
CFM

T2002
T1001 T1300

T2600 T5200

Trion Inc. Trion, Ltd. Trion Deutschland GmbH Fedders International Air Conditioning Fedders International, Inc. Fedders International
101 McNeill Road The Cavendish Centre Boschstr. 60 A-30, Chintels House, 128 Joo Seng Road No. 728 Fuzhou Road
Sanford, NC 27330, USA Winnall Close D - 50171 Kerpen Kailash Colony #05-01 Rm. 3002-3005
Phone: 800-884-0002 Winchester, Hampshire, Phone: +49 (0) 2237 922-103 New Delhi DP Computers Building Raffles City Office Tower
Fax: 800-458-2379 SO23 0LB, UK Fax: +49 (0) 2237 922-104 India 110048 Singapore 368 356 Shanghai, P.R. China, 200001
www.trioninc.com Phone: +44 (0) 1962 840465 email: info@trion-deutschland.de Phone: 91 11 5173 0730 Phone: (65) 6286 0995 Phone: (86-21) 6340 3232
email: sales@trioninc.com Fax: +44 (0) 1962 828619 Fax: 91 11 5173 0743 Fax: (65) 6286 0859 Fax: (86-21) 6340 3867/ 6340 3868
www.trion.co.uk
Form No. 02-0360
email: info@trion.co.uk 2004 Trion Inc. 3/04

You might also like