Technical Specification - Scaffold Boards

John Brash Timber Scaffold Boards are graded to


BS 2482:2009.
We can manufacture three categories of Scaffold Board:
38x225 BSI 1.2m support centres - these boards are either visually
or machine graded.
38x225 BSI 1.5m support centres - these boards are only machine graded.
63x225 BSI 2.5m support centres - these boards are either visually
or machine graded.

Dimension
When measured at a reference moisture content of 20%: NOTE: Crosscutting does not affect the structural integrity of the board and
the board will still comply with BS 2482. Visually graded boards all defects
38mm thick boards: +/-2mm in thickness and/or will have already been visually assessed. Machine graded boards the board
+/-5mm in width. Length +/- 25mm. will have been mechanically assessed along its length.

63mm thick boards: +/-3mm in thickness and/or


+/-5mm in width. Length to the system manufacturer
tolerances. Generally 63mm boards need to be
precision end trimmed to suit the system they are to
be used in.

Table of Strength Properties from BS 2482:2009

Target Board Thickness Target Span Working moment of resistance of a single board where:

mm m An applied load acts only on an An applied load is spread uniformly*


individual board kNm across a minimum of 4 boards kNm

38 1.2 0.50 0.61

38 1.5 0.65 0.81

63 2.5 1.25 1.48

* i.e. via a rigid building pack. If greater loads, e.g. for loading bays, are required these should be calculated and the support spans reduced.

John Brash & Co. Limited., The Old Shipyard, Gainsborough, Lincolnshire, DN21 1NG

Tel: 01427 613858 Fax: 01427 810218 Email: info@johnbrash.co.uk www.johnbrash.co.uk


Technical Specification - Scaffold Boards

Marking Bands are clearly marked with:


The boards must be marked with: MG or VG (designating method of grading)
Manufacturers name 1.2, 1.5 or 2.5m (designating Support Centre )
Support span: BSI 1.2 (or 1.5 or 2.5) at the end of plan banded boards
38mm - 1.2m or 1.5m max Personalised name (FOC on request, maximum 12 characters)
63mm - 2.5m max Date Code
BSI Licence Number
MG (machine graded) (1.2m, 1.5m and 2.5m boards) Year 2009 2010 2011 2012 2013 2014 2015 2016

or VG (visually graded 1.2m or 2.5m boards) Jan-Jun AA BA CA DA EA FA GA HA

Jul-Dec AB BB CB DB EB FB GB HB
In addition, John Brash Ink Jet prints a unique batch
identification number, ensuring traceability from the forest
to the site. Nail Plates
These can be used with or instead of end bands. Typically
We can also offer: they are used in conjunction with end bands. They were
Special grading originally designed to repair a board that had started to
Security branding split and to prevent the split growing. Increasingly they
Fixing of personalised end bands or scaff-plates are put on new boards to help prevent splits starting and
Fire retardant treatments increase the board life. They can be plain or carry either
Individual board FSC & PEFC labelling personalised or quality (BSI required) information.

End Bands Branding


John Brash provides galvanised end bands as standard. For An additional service, this aids security. Usually a name
special applications stainless steel can be offered. John Brash can be branded twice on each side, maximum twelve
end bands give the best solution by using teeth at the end characters. In some cases this can include date, batch
(no nails to fall out or start splits) and nails along the side number or quality (BSI required) information.
(avoiding flapping end bands, a safety hazard with the old
tooth style). Fire Treatments
John Brash offers fire treatments which meets BS EN
13501-1 to Euroclass B (replacing class 1) or Euroclass C
(replacing class 0). This has superseded BS 476:part 6&7
class 0 and 1. Treatment can also be provided meeting the
London Underground specification. Fire retardant treated
boards also have a longer life, as the treatment partially acts
as a preservative.

BS 2482
Licence No 07800

John Brash & Co. Limited., The Old Shipyard, Gainsborough, Lincolnshire, DN21 1NG

Tel: 01427 613858 Fax: 01427 810218 Email: info@johnbrash.co.uk www.johnbrash.co.uk


Technical Specification - Scaffold Boards

Environment
CPET (Central Point of Expertise on Timber, www.
proforrest.net/cpet) is a government directive stipulating
that only timber from legal and sustainable sources can be
used on government funded projects. The use of legal and
sustainable timber is also a condition of many contracts
from main contractors. These directives are just starting
to impact on the access industry. John Brash has full Chain
of Custody with FSC and PEFC accreditation. Wherever
possible John Brash scaffold boards are individually labelled
using ink jet printing with our chain of custody details.

Useful Information
BS 2482:2009 Specification for Timber Scaffold Boards

NASC Documents (www.nasc.org.uk)

TG5:10 Timber scaffold boards An Introduction to


the Revised Standard BS 2482:2009
TG6:10 Care and Maintenance of Scaffold Boards
TG7:07 Scaffold Board Nailplates
TG10:06 Fire Retardant Treatments for Timber Scaffold
Boards and Battens
TG20:08 Guide to Good Practice for Scaffolding with
Tubes and Fittings

Permission to reproduce extracts from BS 2482:2009 is granted by BSI.


British Standards can be obtained in PDF or hard copy formats from the BSI
online shop: www.bsigroup.com/Shop or by contacting BSI Customer Services
for hardcopies only: Tel: +44 (0)20 8996 9001, Email: cservices@bsigroup.com.

BS 2482
Licence No 07800

John Brash & Co. Limited., The Old Shipyard, Gainsborough, Lincolnshire, DN21 1NG

Tel: 01427 613858 Fax: 01427 810218 Email: info@johnbrash.co.uk www.johnbrash.co.uk