T100 - RLT is the timer for holding of call if SACCH multiframe is not decoded than RLT
timer is start and if RLT is reach is zero than call will disconnected.
T3105 - Time between repetitions of physical information to MS. Will be repeated NY1 times.
T3113 - This timer is start after PAGING REQUEST and stop before paging response.
T3260 - The timer is started when AUTHENTICATION REQUEST is sent from MSC.
T3101 - The BSS allocates a SDCCH, if available, and sends a IMMEDIATE ASSIGNMENT message
on the downlink. This message contains the details of allocated SDCCH, TSC, and TA etc. As soon as
the BSS allocates and sends message on the AGCH, it starts a timer T3101. This timer is set in
millisecs.
T3110 - On the receipt of the channel release, the MS starts internal timer T3110 and