You are on page 1of 4

DATa sheet

apC/8X
Advanced Processing Controller
Features That Make a Difference:
Fast, stand-alone processing with flash ROM support
Distributed database processing for up to 160,000 cardholders
with optional expansion
255 time commands for automatic input, output, and reader
mode control
Support for magnetic stripe, Wiegand, and proximity card
technologies
Card, keypad, or card and keypad access support
Reader-by-reader support for variable card formats,
site codes, company codes, and card technologies
Class A, 2-wire supervised input capability
Elevator control
Internal activation and expiration dates for cardholders
Real time full-year clock and calendar
Dynamic memory allocation between card and events storage
Software-linked inputs and outputs for offline control
Communication between host and apC/8X through direct
connect, dial-up, or network using a terminal server
Up to 80 hours onboard memory retention in case of
power failure
Star, bus, or combination star and bus reader configuration
Battery backup available for uninterrupted on-line operation

apC/8X Advanced Processing Controller is an intelligent access applications. Multiple card technologies and card formats can
control and alarm monitoring panel which serves as a basic be used on the same apC/8X, making it ideal for single and
building block for CCURE security management systems. multiple tenant applications and for retrofitting existing systems.
Its bus architecture reduces wiring requirements and overall
apC/8X is available with up to 4 MB static RAM and installation costs.
4 MB EPROM and flash ROM. The panels CMOS static
RAM consumes minimal power for data storage allowing apC/8X is designed to provide advanced functionality in the
longer on-board preservation. The flash ROM makes off-line mode including elevator control, local anti-passback,
firmware updates quick and easy. and alarm or event-initiated output activation.


apC/8X supports optional add-on modules that make the
apC/8X a powerful and flexible platform for a wide variety
of access control, alarm monitoring, and integrated security
features
Advanced Software Features Typically, the host initiates communication with an apC/8X
apC/8X offers many powerful software features such as panel to download new data or change the state of a relay or
timed activation and expiration of cards, support for 32-bit lock output. The apC/8X panel initiates communication with
card numbers, elevator access control, and anti-passback the host to report an important event such as an alarm or to
control. apC/8Xs full-year, real time calendar and clock allows transfer data when its memory is almost full.
activation and deactivation of cards on specified days. apC/8X
also has power, host communication, and fault indicator lights The frequency at which the host dials the apC/8X panel can be
visible on the front of the panel to aid in system diagnosis. adjusted according to the time of day. In addition, each apC/8X
panel can be set to a local time different from the hosts
The panels static RAM consumes minimal power for storing time regardless of time zone differences.
memory and data. apC/8X is also capable of redundant
communication through an optional module. Dialup features may vary according to the host system.

apC/8X features the latest in flash ROM technology allowing apC/8X Memory
you to download panel firmware from the host software. The apC/8X event storage capacity is automatically adjusted
according to the memory required for storing cardholder
Access Control information. Increasing the number of cardholder records
Multiple card technologies and variable card formats can stored decreases the number of events (transactions) that can
be used on the same apC/8X including: Wiegand, magnetic be held. Adding optional features may reduce the number of
stripe, and various proximity cards. With a complete database cardholder records and event storage space as the record
downloaded from the host, apC/8X responds to access size increases.
requests in less than one-half second, regardless of the
number of readers in the system. When an alarm occurs, Star Coupler Module
apC/8X immediately transmits a signal to the host. The Star Coupler Module provides star wiring for card readers
in addition to the standard RS-485 bus wiring. Each reader
Alarm Monitoring port can be configured independently to suit the installation.
apC/8X supports both unsupervised and supervised inputs. The Star Coupler comes with an additional eight unsupervised
Unsupervised inputs are normally closed and report two inputs and eight relay outputs.
conditions to apC/8X: secure or alarm. Supervised input
switches can be normally open or normally closed and report Mini Star Coupler Module
five circuit conditions: short, open, secure, alarm, or line fault. The Mini Star Coupler Module provides an economical way to
wire when additional inputs and outputs are not required. Like
Eight supervised inputs are provided on apC/8X. Another 64 the Star Coupler, the Mini Star Coupler allows configuration of
supervised inputs are available on eight optional I8 boards. eight readers.
Unsupervised Star Coupler and Weigand/Proximity Star
Coupler inputs are also available.
Wiegand/Proximity Star Coupler Module
Set (WPSC)
Card Reader Configuration The WPSC Module is a two board set that connects proximity,
apC/8X can be used in a wide variety of configurations. In its
Wiegand, and Wiegand compatible readers directly to the
base configuration, up to eight card readers can be connected
apC/8X panel. It eliminates the need for the RM-4/RM-4E
through a single RS-485 two-wire bus. The addition of the Star
Personality Board. One WPSC module provides four reader
Coupler module allows you to configure the reader ports in
connections and four inputs. The addition of the second
either star, bus, or a combination of the two. These parts also
module provides a total of eight reader connections and
support up to eight R8 and eight I8 modules.
eight inputs.

apC/8X Dialup Mode RM-4/RM-4E Personality Modules


The dialup mode is a communication technique that connects
The RM-4 Personality Module creates the connectivity
apC/8X to a host system using standard telephone lines and
between a magnetic, proximity, Wiegand, or
modems instead of hardwired or leased telephone lines.
Wiegand-compatible reader and the apC/8X panel.
The RM-4 also provides two supervised inputs and
The dialup mode connection exists only when communication
two outputs when used with optional ARM-1 Modules.
between apC/8X and the host is needed. Connections are
The RM-4E Personality Module has two inputs and two
usually of short duration and are continuously made and
outputs with relays.
broken allowing many apC/8X devices to share few host I/O
ports and telephone lines.
s p e cificatio n s

RM Series Card Readers Electrical


The RM Series Card Readers support magnetic stripe, Autoranging Input. . . . . . . . . . 90 to 260 VAC, 47 to 440 Hz
Output. . . . . . . . . . . . . . . . . . 12 VDC at 3.3 Amp max.
Wiegand, and proximity technologies within a universal Power Consumption. . . . . . . . Less than 40 Watts typical (12W typical
housing. The RMx-4000 Multi-Technology reader provides with 4 RMs, 18W with 8 RMs)
both proximity and contactless smart card technologies within Auxiliary Hardware . . . . . . . . . Relay contacts rated at 30 V AC/DC 2.5
the same housing. Among its many unique features are an Amps inductive, 5 Amps non-inductive

LCD integral keypad, and audible feedback. The RM card


readers provide two supervised inputs and two outputs when
Physical
Dimensions (H x W x D) . . . . . .41.91 x 61.60 x 10.16 cm;
used with the ARM-1. (16.5 x 24.25 x 4.0 in)
Weight apC/8X and
Power Supply. . . . . . . . . . . . . 10.49 kg (23.31 lbs)
Input Module (I8) apc/8X with Star Coupler
The Input Module provides eight Class A supervised inputs. Module and Power Supply. . . 10.8 kg (24 lbs)
A total of eight Input Modules can be connected to one Housing. . . . . . . . . . . . . . . . . 16 AWG metal wall mounted cabinet
with tamper switches on door and rear
apC/8X panel. Input Modules connect on the reader bus which
reduces wiring. Environmental
Operating Temperature. . . . . . 0 to 70C (32 to 158F)
Storage Temperature . . . . . . . -25 to 85C (9 to 185F)
Output Module (R8) Operating and Storage
The Output Module provides an additional eight outputs. Temperature with
A total of eight Output Modules can be installed on one apS battery backup . . . . . . . . 0 to 50C (32 to 122F)
apC/8X panel. Output Modules connect on the reader bus
which reduces wiring. Regulatory
Compliance . . . . . . . . . . . . . . FCC Class B
Certifications. . . . . . . . . . . . . . CE, UL 294, UL 1076
apS Advanced Power System
apS is a stand-alone power supply for apC/8X. apS can be
used in place of the standard apC/8X power supply and
as a backup power supply providing up to 34 amp-hours
of uninterrupted battery backup power for apC/8X and the
readers connected to it. The power supply connects directly to
the power input of apC/8X. apS provides the AC fail and low
battery indicators to the apC/8X.

Configuration Options

Maximum
Module Number of Reader Ports Readers Inputs Outputs
Modules per Unit

Standard apC/8X 1 1 RS-485 8 Bus 8 Class A Supervised 8

Optional Star Coupler1 1 8 RS-485 8 Star or Bus 8 Unsupervised 8

WPSC1 1 (set of 2 modules) 8 Star 8 Class A Supervised

Mini Star Coupler1 1 8 Star or Bus

I/323 1 32 Class A Supervised

R/48 3
2 48 or 96

Input Module (I8) 8 8 x 8 Class A Supervised

Output Module (R8) 8 8x8

RM Reader 8 2 Class A Supervised 8 x 22

RM-4 8 2 Class A Supervised 8 x 22

RM-4E 8 2 Class A Supervised 8 x 22

(1) Either a Star Coupler, WPSC, or Mini Star Coupler can be installed on one apC/8X.
(2) Output requires the ARM-1.
(3) The I/32 and R/48 can still be used but are no longer sold
Wiring Configuration

*Not supported by all hosts. Contact factory for supported configurations.

Wiring Summary
BELDEN NO. OF
WIRE LABEL FROM TO FUNCTION 4 GAUGE (AWG) SHIELDED MAX. LENGTH
PART NO. PAIRS

A apC/8X RM Communication 9841 24 1 Yes 1219.2 m (4000 ft)

B apC/8X RM Power5 8442/8461 22/186 1 No varies7

C ARM Locking Device Control 9462 22 1 Yes 7.62 m (25 ft)

D ARM Power Supply Power 9462 22 1 Yes 7.62 m (25 ft)

91.44 m (300 ft)


E RM ARM Relay Switching 9462 22 1 Yes
60.96 m (200 ft)
91.44 m (300 ft)
F RM Proximity/Wiegand Reader Comm. 9536 18/20/22 3 Yes
60.96 m (200 ft)

G Host apC/8X (RS-485) Comm. 9842 24 2 Yes 1219.2 m (4000 ft)

H Host apC/Converter/Modem (RS-232) Comm. 9855 22 2 Yes 15.24 m (50 ft)

I Host Terminal Server CAT 5-6 2 No 100 m (330 ft)

15.24 m (50 ft)


J Terminal Server apC RS-232 or RS-485 2 No
1219.2 m (4000 ft)
(4) Use Belden Part Number specified or equivalent product.
(5) Not required if powered locally.
(6) Gauge varies according to length of wire. Consult apC/8X manual for details.
(7) Length varies according to application.

Product offerings and specifications are subject to change without notice. Actual products may vary from photos. Not all products include all features. Availability varies by region; contact your sales
representative. Certain product names mentioned herein may be trade names and/or registered trademarks of other companies.

2008 Sensormatic Electronics Corporation. All rights reserved. SH0124-DS-200802-R01-A4-EN