ACTYPE REG FN STADEP STAARR DATE SEQ ATA SUBATA
B737-800 GFO 847 SIN CGK 1/17/2017 15 49 52
B737-800 GFO 121 BTJ CGK 1/16/2017 11 49 52
B737-800 GFO 610 CGK BPN 1/22/2017 48 49 50
B737-800 GFO 650 MDC CGK 1/18/2017 23 49 52
B737-800 GFO 576 BPN CGK 1/22/2017 53 49 52
B737-800 GFO 423 DPS CGK 1/28/2017 7 49 52
PROBLEM
JUST AFTER PARKING APU BLEED IS NOT WORKING
APU BLEED AIR SYST APU BLEED U/S AFTER PARKING
APU FAULT LIGHT ILLUMINATE AFTER SHUTDOWN ENGINE
APU BLEED AIR FROM APU
MAINT
APU REF HIL SEQ 60 APU BLEED AIR NOT AVAILABLE
ACTION
REF FIM 49-50 TAK 801 AFTER BITE FOUND MSG 49-52-017 AT FAULT HISTORY DELTA PRESS SENSO
REF FIM 49-55 TASK 804 RECYCLE OF APU BLEED SWITCH INDICATE NORMAL CHK BY ENGINE MOTO
CLEAN UP ECU ELCONN AND GROUND OPS TEST PERFORMED RESULT GOOD REF FIM 49-50 TASK 8
BITE MSG 49-52017 REVERSE FLOW SHUTDOWN \REF FIM 49-50 TASK 801 EXAMING AND CLEANIN
APU BITE MAINT HISTORY FOUND MSG 49-52188 SURCE CONTROL VALVE LVDT
FAULT
SHOWS MSG 49-52-188
CIRCUIT REFREF
FAILURE FIMFIM
49-53 TASK
49-53 801801
TASK APU ECUSSM
AND REPOST TEST FOUND
49-52-31/P101 CHKSATISFIED
ELCON PLUG P9 SL
INSPECT AND RETIGHTENED PLUG P9 PERFORMED
Month ID_new PirepMarep Notification
2017-01 286406 Pirep TFO170115D1
2017-01 286409 Pirep TFO170111D1
2017-01 286910 Pirep TFO220148D1
2017-01 286959 Pirep TFO180123D1
2017-01 287086 Marep TFO230153D1
2017-01 287768 Marep TFO280107D1
Number of Last Date
No ATA A/C Reg Detail Problem Occurrence
Pireps
BITE ZTC NO FAULT. TRY TO CROSS CHANGE CABIN TEMP SENSOR WITH AFT CABIN
TEMP SENSOR RESULT GOOD. OPC TEST CONTROL CAB TEMP SELECTOT RESULT
SATISFIED. REF FIM 21-61 TASK 801
B.BITE TEST FOUND ACT FAULT CLEAN UP ZONE CONTROLLER SYS#2 AND
RESECURED. REBITE TEST RESULT NORMAL PSE MONITOR FUTHER FLIGHT FIM TASKL
21-62/801
RH PACK ZONE CONTROLLER BITE FOUND RAM DOOR ACT RED LT ILL AND VERIFY ALL
GO PACK ON RECALL RESULT GOOD REF FIM 21-62 TASK 801
CHECK PITOT AND STATIC HEATING NORMAL.AND NO FOD.REPLACED ISFD OPC CHECK
RESULT GOOD.REF AMM 33-24-02/P401.
TRY TO BITE AUTO PILOT FOUND AUTO PILOT PASS FIM 22-11 TASK-801
APU BITE MAINT HISTORY FOUND MSG 49-52188 SURCE CONTROL VALVE LVDT
SHOWS CIRCUIT FAILURE REF FIM 49-53 TASK 801 AND SSM 49-52-31/P101 CHK
ELCON PLUG P9 SLIGHLY LOOSE SO INSPECT AND RETIGHTENED PLUG P9 PERFORMED