You are on page 1of 2

= berekende resultaten

= in te vullen cellen

*Not that you care but these are not the dimensions of my furnace

CASTABLE REFRACTORY VOLUME AND COST CALCULATOR


ISOLERENDE BUITENBEKLEDING
buitenbekleding VOLUME : buitenbekleding productnaam WescoLite
hoogte uitwendig= 73 cm deksel= 7916.81 cm3 soortelijk gewicht 0.5 kg/liter
hoogte inwendig= 62 cm wand= 19173.52 cm3 benodigde kg 18.49 kg
diameter uitwendig= 46 cm bodem= 9896.01 cm3 kg/zak 20 kg
diameter inwendig= 41.5 cm zakken nodig 0.92 zak
TOTAAL inhoud= 36986.33 cm3 aantal zakken 1 zak zelf beslissen
uitlaat diameter= 10 cm TOTAAL inhoud (liters)= 36.986 liter prijs per zak 20.00
afvoer diameter= 4 cm kosten 20.00
dikte deksel= 5 cm
dikte bodem= 6 cm
wanddikte= 2.25 cm

HOGE TEMPERATUUR BINNENBEKLEDING (alleen indien van toepassing)


binnenbekleding VOLUME binnenbekleding productnaam EB 10 ST
inwendige hoogte= 44 cm deksel= 12666.89 cm3 soortelijk gewicht 3.2 kg/liter
inwendige diameter= 31 cm wand= 26306.89 cm3 benodigde kg 167.60 kg
bodem= 13400.84 cm3 kg/zak 25.00 kg
dikte deksel= 8 cm zakken nodig 6.704 zak
dikte bodem = 10 cm TOTAAL inhoud= 52374.62 cm3 aantal zakken 7 zak zelf beslissen
wanddikte= 5.25 cm TOTAAL inhoud (liters)= 52.375 liter prijs per zak 20.00
kosten 140.00

gewicht deksel 44.49245422 kg nodig 186.09 kg


besteld 195 kg
TOTAAL 160.00
*This spreadsheet was built and designed by me. Its accurancy is not guaranteed.
Use it at your own will. It is intended for a cylindrical furnace with an outer insulation lining and
an inner primary lining.

*The inner primary lid lining is calculated as if it goes


to the same outer diameter as the top insulation lid lining. This is for ease
of construction and to insure a good bond to the skin.
In doing this it does calculate some of the body insulation which will actually be the lid primary lining.
I did not change this so that the single layer calculation would be correct.
I figure many more people will be using it anyway.

*The bottom inner lining does not go to the metal skin but to the inside of the outer insulation lining.
For a single layer furnace just use the top calculator.
It does not take into account the burner opening, collar, crucible block, mix loss, or extra needed.