21FL, Doosan Tower 18-12 Eulijo-6Ga,

Jung-Gu, Seoul, Korea 100-7030


T 82 2 3398 8532
F 82 2 3398 8509

DOOSAN Emission Data for DP Engines

October 15th, 2015

The emission data are measured according to the test procedures and it may vary among production
engines. All data applies to an engine in new condition.

DP158
Stand-by
NOx THC CO PM
Hz Power
PS kW g/kWh g/kWh g/kWh g/kWh
60Hz 756 556 13.25 0.22 0.88 0.074
50HZ 693 510 12.84 0.26 0.76 0.077

DP180
Stand-by
NOx THC CO PM
Hz Power
PS kW g/kWh g/kWh g/kWh g/kWh
60Hz 899 661 11.80 0.12 0.71 0.069
50HZ 832 612 13.60 0.13 0.62 0.066

DP222
Stand-by
NOx THC CO PM
Hz Power
PS kW g/kWh g/kWh g/kWh g/kWh
60Hz 1126 828 11.11 0.12 0.69 0.082
50HZ 1023 753 10.70 0.11 0.73 0.104

Yunyoung Cho
Yunyoung Cho / Regional Manager
Generator Sales Team / Engine BG
DOOSAN INFRACORE CO., LTD.