Size and Weight: 6.625'' 27.70 ppf 0.

362'' wall IEU


Grade: V-150
Drill Pipe Performance Sheet Range: 3
Asset Number: WS43-20 Tool Joint: 8.500'' x 4.250'' 6 5/8" FH

Pipe Body: Tubular Assembly:


Nominal Ultra Class Premium
100% RBW 95% RBW 90% RBW 80% RBW Adjusted Weight (lbs/ft): 34.90 Fluid Displacement (gal/ft): 0.53
Approximate Length (ft): 44.6 Fluid Displacement (bbls/ft): 0.0127
OD (in): 6.625 6.589 6.553 6.480
Wall Thickness (in): 0.362 0.344 0.326 0.290 Box TJ Length (in): 18 Fluid Capacity w/IPC (gal/ft): 1.34
Nominal ID (in): 5.901 5.901 5.901 5.901 Pin TJ Length (in): 14 Fluid Capacity w/IPC (bbls/ft): 0.0319

Tensile Strength (lbs): 1,068,395 1,012,042 955,998 844,835 Upset Type: IEU Fluid Capacity w/o IPC (gal/ft): 1.35
Torsional Strength (ft-lbs): 152,589 144,452 136,372 120,382 Max Upset OD (in): 6.906 Fluid Capacity w/o IPC (bbls/ft): 0.0321
Drift Size (in): 4.125
Burst Capacity (psi): 14,343 15,573 14,753 13,114
Collapse Capacity (psi): 7,970 7,037 6,230 4,592

18
0

Note: These are OEM values that may vary with actual values due to mill tolerances, IPC tolerances, OEM rounding, and other
Notes: Body properties are calculated based on uniform OD and wall thickness. factors. Pipe is purchased at a guaranteed 95% RBW. IPC is applied to a nominal thickness of 0.009''. Pipe will have an ID of
Burst capacity for Nominal (100% RBW) based on 87.5% RBW per API. 5.843'', which is smaller than pipe purchased at 87.5%.

Connection: 6 5/8" FH Elevator Shoulder:


TJ OD (in): 8.500
TJ ID (in): 4.250
MYS (ksi): 120 Maximum MUT (ft-lbs): 65,000 Smooth Edge Height (in): 3/32
Tension at Shoulder Separation @ Max MUT (lbs): Tensile Limited Smooth Edge OD (in): 8.688
Tension at Connection Yield @ Max MUT (lbs): 1,843,000 SE Elevator Shoulder Capacity (lbs): 2,251,500

Minimum MUT (ft-lbs): 54,200 Nominal TJ OD (in): 8.500


Tension at Shoulder Separation @ Min MUT (lbs): 1,934,090 Nominal TJ OD Elevator Shoulder Capacity (lbs): 1,972,800
Tension at Connection Yield @ Min MUT (lbs): 2,102,266
Assumed Elevator Bore (in): 7.031

N/A Tool Joint Torsional Strength (ft-lbs): 108,353


N/A Tool Joint Tensile Strength (lbs): 2,102,266
Note: Elevator capacity based on assumed elevator bore, no wear factor, and contact stress of 110, 100 psi. An increased
Note: MUT values are based on a friction factor of 1.0. There is no published pressure rating for this connection. elevator shoulder OD increases elevator capacity without affecting make-up torque.

The technical information containted herein, including the product performance sheet and other attached documents, has been extracted from information available from the manufacturer and is for reference only and not a recommendation. The user is fully responsible for the accuracy and suitability of use of the technical
information. Workstrings International cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated based on uniform OD and wall thickness. No safety factor is applied. The information provided for various
inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable operation limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices,
and to apply a prudent safety factor suitable for the application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

www.workstringsinternational.com 07-Dec-15
Download the Workstrings International Pipe Specification App on the App Store or Google Play
Operational Limits of Drill Pipe
Connection 6-5/8 FH Tool Joint OD (in) 8.500 Tool Joint ID (in) 4.250 Tool Joint Specified Minimum 120,000
Yield Strength (psi)

Pipe Body 80 % Inspection Class Pipe Body OD (in) 6.625 Wall Thickness (in) 0.362 Pipe Body Grade V-150

Combined Loading for Drill Pipe at Combined Loading for Drill Pipe at
Maximum Make-up Torque = 65,000 (ft-lbs) Minimum Make-up Torque = 54,200 (ft-lbs)

Operational Assembly Pipe Body Connection Max Operationa Assembly Pipe Body Connection
l Torque Max Tension Max Tension Max Tension
Torque Max Tension Max Tension Tension
(ft-lbs) (lbs) (lbs) (lbs) (ft-lbs) (lbs) (lbs) (lbs)

0 844,800 844,800 1,822,400 0 844,800 844,800 1,911,300

844,500 1,822,400 2,800 844,600 844,600 1,911,300


3,400 844,500
843,500 1,822,400 5,600 843,900 843,900 1,911,300
6,700 843,500
10,100 841,900 841,900 1,822,400 8,400 842,800 842,800 1,911,300

13,500 839,500 839,500 1,822,400 11,200 841,200 841,200 1,911,300

16,900 836,500 836,500 1,822,400 14,000 839,100 839,100 1,911,300

20,200 832,900 832,900 1,822,400 16,800 836,600 836,600 1,911,300

23,600 828,400 828,400 1,822,400 19,600 833,600 833,600 1,911,300

27,000 823,300 823,300 1,822,400 22,400 830,100 830,100 1,911,300

30,300 817,600 817,600 1,822,400 25,200 826,100 826,100 1,911,300

811,100 1,822,400 28,000 821,700 821,700 1,911,300


33,700 811,100
803,700 1,822,400 30,800 816,700 816,700 1,911,300
37,100 803,700
40,400 795,800 795,800 1,822,400 33,600 811,300 811,300 1,911,300

43,800 786,900 786,900 1,822,400 36,400 805,300 805,300 1,911,300

47,200 777,200 777,200 1,822,400 39,200 798,800 798,800 1,911,300

50,600 766,600 766,600 1,822,400 42,000 791,800 791,800 1,911,300

53,900 755,400 755,400 1,822,400 44,800 784,200 784,200 1,911,300

57,300 743,000 743,000 1,822,400 47,600 776,000 776,000 1,911,300

60,700 729,600 729,600 1,822,400 50,400 767,200 767,200 1,911,300

715,400 1,822,400 53,200 757,900 757,900 1,911,300


64,000 715,400
Operational drilling torque is limited by the Make-up Torque. Operational drilling torque is limited by the Make-up Torque.

Connection
Make-up Torque Range
Make-up Torque Connection Max
(ft-lbs) Tension (lbs)
Min MUT 54,200 1,911,300
55,400 1,953,600
56,600 1,995,900
57,800 2,038,200
59,000 2,074,500
60,200 2,024,100
61,400 1,973,700
62,600 1,923,300
63,800 1,872,900
Max MUT 65,000 1,822,400
Note: Recommended MUT should always be used when possible. If not possible, MUT should be as close to Recommended MUT as possible.

Note: The technical information contained herein, including the product performance sheet and other attached documents, is for reference only and should not be construed as a recommendation. The user is fully responsible for the accuracy and
suitability of use of the technical information. NOV Grant Prideco cannot assume responsibility for the results obtained through the use of this material. No expressed or implied warranty is intended. Drill pipe assembly properties are calculated
based on uniform OD and wall thickness. No safety factor is applied. The information provided for various inspection classes and for various wear conditions (remaining body wall) is for information only and does not represent or imply acceptable
operating limits. It is the responsibility of the customer and the end user to determine the appropriate performance ratings, acceptable use of the product, maintain safe operational practices, and to apply a prudent safety factor suitable for the
application. For API connections that have different pin and box IDs, tool joint ID refers to the pin ID. Per Chapter B, Section 4 VII of the IADC drilling manual, it is recommended that drilling torque should not exceed 80% of MUT.

06-17-2015

You might also like