ABS Digimatic indicator ID-C is a standard digital indicator. A large Examples of use
LCD incorporating 11mm characters (existing products: 8.5mm) is used
to improve visibility, and three large, easy-to-press buttons are used
in the design to make operations easier to perform. In addition, this
affordable product has various measurement functions, including the
ability to perform scaling calculations, judge tolerance, hold data, and
perform general comparison measurements.
2
reading measurement values, usability and functionality
Power switch
Application products for one-touch quick
Data output (when connected to an
external device)
Data hold (when no external device is
6. measurement
Parameter setting mode
connected) Various application products are available that enable you to perform one-touch
Count direction switching, tolerance judgment Switches between the ABS (preset) and quick measurement of the thickness of small parts, papers, felt, lenses, and
setting, resolution switching, scale factor INC (zeroset) measurement modes pipes, as well as the depth of narrow grooves on cylindrical workpieces, groove
setting, and function lock setting depth, and steps.
ABS measurement mode INC measurement mode (For details, see pages 8-11.)
Preset using a reference gage to measure the Zeroset using a reference gage to perform
absolute value from a measurement reference a comparison measurement of the difference ABS Digimatic
between the reference gage and measured
workpiece upright gage
Measured workpiece
54.267
reference reference
gage gage
ABS Digimatic
Operation in ABS (preset) measurement mode Operation in INC (zeroset) measurement mode depth gage
-EASURINGSPANMM
-ODEL)$
#8
#ERTIlCATE.O
4EMPERATURE
3ERIAL.O
3TANDARD4EMPERATURE
)NSPECTIONSTANDARD-ITUTOYOSTANDARD 1#-ANAGER4+OSUDA
-AXIMUM0ERMISSIBLEERROR
/VERALL ! /VERALL
(YSTERESIS 3 (YSTERESIS
-
25.4mm or 50.8mm)
/VERALLMAGNIlCATIONANDLINEARITY
-ETHODOFINSPECTION-)454/9/.OSIGN *UDGEMENT0ASSED
"ASEDON!3-%"-
4RACEABLETO.-)*!)34BY*#33.O 4HEQUANTIZINGERRORCOUNT IS
.)34VIA.O
- EXCLUDEDFROMTHESPECIlCATIONVALUE
If dust or coolant gets into the gap between the spindle and main unit while using the
%RRORS;M=
lifting knob, the spindle travel may become rough or the indicator may fail altogether.
50 $/7. 0OSITIONMM
Therefore avoid using the ID-C in environments containing dust or coolant mist.
-ITUTOYO#ORPORATION
3
ABS Digimatic Indicator ID-C
SPECIFICATIONS
Inch/Metric ISO/JIS Type and ANSI/AGD Type
Order No. Measuring range Accuracy*[1 Hysteresis* Repeatability* Measuring force Mass Remarks
Resolution .00005"/.0001"/.0005"/0.001mm/0.01mm
543-391 543-391B .5" .00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.5N or less 170g
543-392 543-392B .5" .00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.5N or less 170g
543-395 543-395B .5" .00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 0.7, 0.6, 0.4N or less 170g Low measuring force
543-396 543-396B .5" .00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 0.7, 0.6, 0.4N or less 170g Low measuring force
543-471B 1" .00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.8N or less 190g
543-472B 1" .00010"/0.003mm .00010"/0.002mm .00010"/0.002mm 1.8N or less 190g
543-491B 2" .00020"/0.005mm .00010"/0.002mm .00010"/0.002mm 2.3N or less 260g
543-492B 2" .00020"/0.005mm .00010"/0.002mm .00010"/0.002mm 2.3N or less 260g
Resolution .0005"/0.01mm
543-401 543-401B .5" .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.9N or less 170g
543-402 543-402B .5" .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.9N or less 170g
543-405 543-405B .5" .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.5, 0.4, 0.3, 0.2N or less 170g Low measuring force
543-406 543-406B .5" .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 0.5, 0.4, 0.3, 0.2N or less 170g Low measuring force
543-475B 1" .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 1.8N or less 190g
543-476B 1" .0010"/0.02mm .0010"/0.02mm .0005"/0.01mm 1.8N or less 190g
543-495B 2" .0015"/0.04mm .0010"/0.02mm .0005"/0.01mm 2.3N or less 260g
543-496B 2" .0015"/0.04mm .0010"/0.02mm .0005"/0.01mm 2.3N or less 260g
: ANS/AGD Type
Note) Products with an Order No. suffixed B have a flat back, and other models have a back with a lug.
* Overall hysteresis and repeatability specifications are valid for normal measurement at 20C, and the quantizing error of 1 count is excluded.
COMMON SPECIFICATIONS
Display: 6-digit LCD, sign Position detection method: Capacitance type absolute linear encoder
Contact point: Spherical tip SR = 1.5mm (carbide tipped), Battery: SR44 (silver oxide button cell) 1, part No. 938882
part No. 901312 (for ISO/JIS Type) Battery life: Approximately 7,000 hours of continuous use
part No. 21BZB005 (for ANSI/AGD Type) Maximum response speed: Not restricted (except for scanning measurement)
Spindle orientation for measurement: Service temperature range: 0 to 40C
- Standard model that has a 12.7mm measuring range: No restrictions Storage temperature range: 0 to 60C
- Standard model that has a 25.4mm or 50.8mm measuring range: Normally
at any position between the spindle pointing vertically downward to the
spindle horizontal. To perform measurement with the spindle pointing above
the horizontal requires a reverse-position coil spring (special accessory).
- Low measuring force models: See 'Setting measuring force on low
measuring force models' on page 5.
4
Setting measuring force on low measuring force models
543-404/404B/405/405B/406/406B 543-394/394B/395/395B/396/396B
Weight Maximum
Spindle orientation Spring Weight Maximum
(approximately 0.1 N) measuring force
Spindle orientation Spring
(approximately 0.1 N) measuring force
Yes Yes 0.5N Yes Yes 0.8N (0.3+0.4+0.1=0.8)
Yes No 0.4N Yes No 0.6N
Pointing vertically downward Pointing vertically downward
No Yes 0.3N No Yes 0.4N
No No 0.2N No No Not guaranteed
Horizontal Yes No 0.2N Horizontal Not guaranteed
Note) Operation using configurations other than shown above is not guaranteed. Note) Operation using configurations other than shown above is not guaranteed.
DIMENSIONS
ISO/JIS Type
57.7
85.2
59
54
59
6
.5
46.5
54.4
0
8 -0.009
59
17
M2.5X0.45
70
84.8
21.2
7.3
0
8 -0.009
19.5
7.6
8 -0.009
0
19.5
M2.5X0.45
52
7.3
ANSI/AGD Type
19.2
10.9 28.8 19 31.5 11 19.2 31.5 11
.43" 1.13" 3/4" .76" 1.24" .43" .76" 1.24" .43"
6.35
1/4"
1.97"
50.1
2.27"
57.7
2.13"
3.35"
85.2
54
2.32"
59
2.32"
59
1/4"
1.74"
6.5
44.2
50.8
2"
0
20 14.7
.79" .58"
9.52 -0.03
2.32"
2.67"
59
67.7
.375"
83.85
3.30"
3.74"
6.35
95
109.65
4.32"
Contact point
1/4"
6.35
42.15
1.66"
1.02"
0
9.52 -0.03
17.2
.68"
2.62"
66.65
52
Contact point
6.35
1/4"
No.4-48 thread
5
Functions and accessories
Functions
Zero-setting function 330 rotary display Data output
(INC measurement mode) (when connected to an external device)
Preset function (ABS scale origin setting) From the output terminal, measurement data can
The preset value can be changed easily by using the
330 330 be output to a PC via a compact printer, Digimatic
SET (digit movement) and MODE (value change) mini processor DP-1VR, or input tool by pressing
buttons. the button below the display. Wireless transmission
of measurement data to a PC can also be performed
using the measurement data wireless communication
system U-WAVE.
Resolution switching
(For 0.001mm or .00005" resolution models)
Models with 0.001mm resolution are capable of
displaying in 0.01mm resolution. Models with
.00005" resolution are capable of displaying in
.0001" and .0005" resolution. Select the resolution
according to the application.
the set upper and lower limit values and displays (when no external device is connected)
the result as a symbol. Enlarged display of the OK
and NG symbols is possible.
Input tool
No.264-012-10 IT-012U (special accessory)
Calculation: f(x) = Ax
Mounting the ID-C on a measuring jig and setting Function locking
the calculation factor (to any value) allows direct Ensures reliability of measurement by locking the
measurement without using a conversion table and settings to prevent preset function settings from
improves measurement efficiency. being changed by mistake.
6
Standard accessories Interchangeable contact points for Mitutoyo dial gages U-WAVE
(measurement data wireless communication system)
Operation manual Digimatic mini processor DP-1VR No. 264-504
Inspection certificate Multiplexer MUX-10F, No. 264-002
1 Lifting lever (finger hook) Shell Flat Needle
Display unit EC-101D, No. 542-007
(Only for models that have a 25.4mm or 50.8mm measuring range) Various types of contact points are available.
Input tool (USB keyboard signal conversion type)
Silver oxide button cell for the monitor: SR44 1 IT-012U, No. 264-012-10
Part No. 938882 Various backs for standard Mitutoyo (2 series) dial gages
Weight (only for low measuring force models) Reverse-position coil spring
Part No. 02ACA571
(for models that have a 25.4mm measuring range)
Part No. 02ACA773
Special accessories (for models that have a 50.8mm measuring range)
6
7
Application Products
Application Products
ABS Digimatic Thickness Gage
547-300S
547-320S 547-400S
Unit: mm
8
ABS Digimatic Lens Meter
Unit: mm
9.3
SR2 6
9.3
S4 spherical 4.8
SR3 contact point
30
Anvil Anvil Anvil
Standard accessory
Anvil adjustment: 30.3 (Throat depth)
Concave lens Convex lens Moon lens 12 mm SR3 85
Designed for measuring the thickness of concavo-convex lenses and flat objects
The thickness of flat objects can be measured by replacing the anvil.
Includes a spherical contact point.
9.3
30
6
4.8
Inch/Metric ANSI/AGD Type
SR2
30
Order No. Resolution Measuring range Throat depth Anvil adjustment Accuracy Measuring force
547-312S Anvil displacement: 12 mm
547-312S .0005"/0.01mm 0~.4"/0~10mm 30mm 12mm SR3
.001" or less 85 1.5N or less
Unit: mm
Contact
point
3
3
Order No. Resolution Measuring range Throat depth Minimum inside Accuracy 21
Measuring force
diameter of pipe
547-360 0.01mm 0~10mm 20mm 3.5mm 20m or less 1.5N or less
Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice.
2. The accuracy specification does not include the quantizing error of 1 count.
3. Left-handed models can be supplied to special order.
9
Application Products
Unit: mm
ABS Digimatic Groove Gage
Contact
point
Best suited for measuring the depth of narrow grooves on
1 Anvil
66
cylindrical workpieces
The contact point and measuring face of the anvil are
1mm thick blades.
30.3 (Throat depth)
85
Inch/Metric ANSI/AGD Type
Order No. Resolution Measuring range Throat
depth
ontact point and anvil Accuracy
C
dimensions (W D) Measuring force
547-316S .0005"/0.01mm 0~4"/0~10mm 30mm 6.5mm x 1mm .001" or less 1.5N or less
30
6.5
55
Metric ISO/JIS Type
Order No. Resolution Measuring range Throat
depth
Contact point and anvil Accuracy
dimensions (W D) 1 Measuring force
85
547-315 0.01mm 0~10mm 30mm 6.5mm x 1mm 20m or less 1.5N or less
547-316S
Note) 1. Changing the contact point requires total adjustment, including the main display unit. Contact Mitutoyo for advice.
2. The accuracy specification does not include the quantizing error of 1 count.
3. Left-handed models can be supplied to special order.
Unit: mm
Suitable for measuring the depth of holes, narrow grooves, and steps.
The lifting lever can be used either on the left or right sides.
(105)
(67)
16
(35)
(11)
(10)
17
SR
5 1.5
547-218S
6
A
Inch/Metric ANSI/AGD Type
Measuring Measuring Base Contact point: Carblde-
Order No. Resolution range Stroke Accuracy Extension rods
force Length Width Flatness tipped ball
547-217S .0005"/0.01mm 0~8" .5" .001" or less 1.5N or less 2.5" .63" .0002" or less 4 pcs. (.5",1",2",4")
547-218S .0005"/0.01mm 0~8" .5" .001" or less 1.5N or less 4" .63" .0002" or less 4 pcs. (.5",1",2",4")
21JAZA242
547-257S .00005"/0.001mm 0~8" .5" .0002" or less 1.5N or less 2.5" .63" .00008" or less 4 pcs. (.5",1",2",4")
547-258S .00005"/0.001mm 0~8" .5" .0002" or less 1.5N or less 4" .63" .00008" or less 4 pcs. (.5",1",2",4")
10
Unit: mm
40
The support plate allows easy reading by tilting the anvil.
Carbide measuring faces (for the contact point and anvil) 59 92
The lifting lever can be used either on the left or right sides. 10 60
Effective throat depth
6.3
55
45
5
547-066S Support plate 20 Flat anvil
Inch/Metric ANSI/AGD Type
Order No. Indicator stroke Resolution Remarks (contact point) Effective throat depth Workpiece height Accuracy Measuring force
547-066S .5" .0005"/0.01mm .248" DIA flat type .59" 1" .001" or less 1.5N or less
Unit: mm
SR
40
115
1.5
12
35
547-035S
Center of anvil 1 Center of 60
Measuring depth 45 20 contact point
95
Inch/Metric ANSI/AGD Type
Order No. Resolution Measuring range Anvil Workpiece height Accuracy Measuring force
547-034S .0005"/0.01mm .5" 1.57" DIA steel type 1.2" .001" or less
547-033S .00005"/0.001mm .5" 1.97" DIA ceramic type 1.2" .0001" or less 1.5N or less
547-035S .00005"/0.001mm .5" 1.57" DIA steel type 1.2" .0001" or less
11
Export permission by the Japanese government may
be required for exporting our products according to
the Foreign Exchange and Foreign Trade Law. Please
consult our sales ofce near you before you export
our products or you offer technical information to a
nonresident.
Aurora, Illinois
(Corporate Headquarters)
Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this printed matter as Westford, Massachusetts
well as other technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs. The
Huntersville, North Carolina
stated standards, similar technical regulations, descriptions and illustrations of the products were valid at the time of printing. In addition, the latest applicable
version of our General Trading Conditions will apply. Only quotations submitted by ourselves may be regarded as definitive. Mason, Ohio
Mitutoyo products are subject to US Export Administration Regulations (EAR). Re-export or relocation of Mitutoyo products may require prior approval by an Plymouth, Michigan
appropriate governing authority.
Mitutoyo Corporation
City of Industry, California
Trademarks and Registrations
Designations used by companies to distinguish their products are often claimed as trademarks. In all instances where Mitutoyo America Corporation is aware
20-1, Sakado 1-chome,
of a claim, the product names appear in initial capital or all capital letters. The appropriate companies should be contacted for more complete trademark and Takatsu-ku, Kawasaki-shi,
registration information.
Kanagawa 213-8533, Japan
We reserve the right to change specifications and prices without notice.
T +81 (0) 44 813-8230
F +81 (0) 44 813-8231
2009 Mitutoyo America Corporation, Aurora IL 0409-09 Printed in USA, June 2009 http://www.mitutoyo.co.jp
Note: All information regarding our products, and in particular the illustrations, drawings, dimensional and performance data contained in this pamphlet, as well as other
technical data are to be regarded as approximate average values. We therefore reserve the right to make changes to the corresponding designs, dimensions and weights.