CONFIGURING THE RSSD
o
Internet and Shop LAN
Cee eT
41. Internet interface
This interface is connected to your company network and must be able to access a “hitpsi/" type web
address (TLS/SSL on outgoing port 443).
Please choose one of these 2 configurations:
1. Dynamie addressing configuration (DHCP) =i
-OR-
2. Static IP configuration
IP address for RSSD on internet interface: 10 15 10 a]
Subnet mask for RSSD on internet interface: 255 255 255 252
Default gateway for RSSD on internet interface 15 10 1
Exompes 10.5 10 20
2. Shop LAN interface
This interface is connected to the BOBST machines through the Shop Floor LAN. Usually this LAN is
separated from your Company LAN either physically (switch or hub) [1] or logically (VLAN) [2]. The typical
range of addresses used by this LAN is 192, 168, 100.0/24,
Please choose one of these 2 configurations:
1. Ifthe Shop Floor LAN is physically separate, we recommend keeping the complete default =]
address range:
IP address range for the RSSD on Shop LAN interface 192 168 100 0-285
‘Subnet mask of the RSSD on Shop LAN interface 285 255 255 °
-OR-
2. Ifthe Shop Floor LAN is on your company network, you must reserve a full range of 255 IP
addresses:
IP address range for the RSSD on Shop LAN interface’ 0-265
‘Subnet mask of the RSSD on Shop LAN interface “ °
Example: 192 168 200 0.285
4 Roast SERVICES
‘The IP address ranges for the 2
interfaces must not be identical
495
4.08
407
408