Professional Documents
Culture Documents
____________________________________________________________
Requested by:
________________________________
1
JOAN MULET, S.L.
2
JOAN MULET, S.L.
1. PURPOSE OF PROJECT:
The purpose of this project is to verify that the street lighting columns under study in this
project will withstand the forces they will be submitted to in certain wind conditions, not exceeding
the elastic limit of the material in the different cross-sections as specified in Standard UNE-EN 40-
3-3:2003.
The project stems from the need to make a study of the static behaviour of the column when
subjected to certain wind conditions, seeking the correct dimensions of the pole to ensure that the
values defined for the elastic limit of the material are not exceeded.
The entity requesting this study is ESCOFET 1886, S.A., domiciled at Ronda Universitat,
20, Barcelona, holding Fiscal Registration No. A-08042764.
3
JOAN MULET, S.L.
Five lighting columns with a truncated conical body were studied, known as FUL-7\10,
FUL-7\9, FUL-9 (formerly FUL-2), FUL-10 (formerly FUL-3) and FUL-12 (formerly FUL-1),
each of which has a different light shape and structure. The models can be seen in the attached
annexes. The characteristics of each model are detailed below:
UPPER
LOWER
EXTERNAL No. of No. of BASE
MODEL HEIGHT (m) EXTERNAL
DIAMETER PROJECTIONS COMPARTMENTS
DIAMETER (mm)
(mm)
FUL-7\10 7 200 77 3 1
FUL-7\9 7 165 77 3 1
FUL-9 9 200 77 3 1
FUL-10 10 200 77 3 or 5 1
FUL-12 12 240 88 4 1
In this particular case, each model is going to be studied in the following materials:
- Stainless steel AISI 316 I (e = 4 mm).
- Galvanized steel (e = 4 mm).
- Corten steel (e = 5 mm).
The light used for the lighting columns in question is the SICOMPACT MIDI A2/S2/R2 from
SITECO. The weight and size specifications of the light are given in the annex.
Due to the different characteristics of each model, all the lighting columns will be studied.
6. CHARACTERISTICS OF MATERIALS:
The materials used for calculating the lighting columns are as follows:
4
JOAN MULET, S.L.
7. DESCRIPTION OF LOADS:
The loads that need to be taken into account for calculations are the actual weight of the
pole and wind action.
To calculate the wind load on the pole, standard UNE-EN 40-3-1 will be used. To determine the
strength the wind exerts on the projections, standard NBE AE-88 will be used.
The wind force, obtained from standard UNE-EN 40-3-1, depends on the shape of the pole, its
emplacement, geographical position and topographical situation.
The actual weight of the lighting pole or column is obtained from the density of the iron; in this
particular case, it is generated by the calculation programme itself. The actual weight of the light is
21 kg, as specified in the annex.
These loads should be rounded up to make the calculation even more reliable. The weighting
coefficients are 1.2 for permanent loads (weight of pole) and 1.4 for variable loads (wind action).
The following location and geographical position conditions were considered for the lighting
column calculations:
-Terrain category I: this entails the installation of the lighting columns along the open seashore, or
by a lake with an exposed wind length of under 5 km, or on flat, open ground with no obstacles.
5
JOAN MULET, S.L.
The limit state will be that corresponding to the stress obtained in the different critical sections,
relating to the point where the pole is planted in the ground, the upper part of the compartment
cover and the point where the arm begins. To calculate the stress at these points, the bending
moments at the two axes of the pole and the torsional moment will be taken into account.
The calculated wind direction will be the one with the most unfavourable impact. In this case, this
direction has been regarded as the one blowing directly onto the side where the base compartment
cover is located.
The stresses generated in the whole length of the pole need to be studied, especially at the base, the
upper part of the base compartment and the point where the outreach starts, these being the parts of
the structure which, due to the combination of the value of the bending moment and the value of the
resistant section, show the highest risk of reaching the limit state.
To calculate the structure, we need to calculate the force exerted by the wind load (variable load)
and the weight of the pole (permanent load). The weighting coefficients of the loads are 1.2 for
permanent loads and 1.4 for variable loads, according to Standard UNE-EN 40-3-3.
The actual weight includes the weight of the pole and the lights.
The wind load will be the figure defined by Standard UNE-EN 40-3-1, which specifies loads for
designing street lighting columns and poles.
6
JOAN MULET, S.L.
q(z) = fCe(z)q(10)
where:
is the coefficient that depends on the height of the lighting column or pole
is the coefficient that depends on the dynamic behaviour of the pole
f is the topography coefficient
Ce(z) is the coefficient that depends on the terrain and the height above ground level.
q(10) is the benchmark wind pressure, which is determined by the equation:
q(10) = 05(Cs^2)(Vref.^2)
where:
- is the air density, equal to 1.25 kg/m3
-Cs is a coefficient which, for street lighting columns, should be taken as 0.96, the return period
being around 25 years
-Vref is the benchmark wind speed
Once the wind pressure has been obtained, the force it exerts on the pole can be determined,
multiplying the pressure figure by the projected surface area and a shape factor (c) that depends on
the shape of the column and the number of Reynolds.
To calculate the force exerted by the wind on the outreach arms, the section referring to wind loads
in Basic Building Standard AE-88 will be used.
Once the loads on the pole have been calculated, the bending moment rule will be determined. This
calculation is made with the assistance of the CYPE computer programme.
As this is a truncated conical pole, and therefore has a variable area, the pole will be divided into
various equal sections to make the calculations.
7
JOAN MULET, S.L.
All the sections mentioned earlier need to be studied and the same calculation process will be
followed for all of them.
The calculation procedure varies according to whether it is a standard open or closed cross-section.
Bending strength and torsional strength will be calculated in accordance with the following
equations:
where:
1 is a coefficient with a value obtained from the curve of figure 2 of Standard UNE-EN 40-3-
3 where the value of = ( R / t ) f y / E
0,474 E
2 is a coefficient whose value is equal to but not higher than 1.0.
f y ( R / t )1,5
8
JOAN MULET, S.L.
Zp is the plastic modulus of the standard closed cross-section (in mm3) which for circular
sections is 4R2t.
where:
t2 E
3 is a coefficient whose value is equal to but not higher than 1.
t 2 E + 0,07 R L f y
t2 E
4 is a coefficient whose value is equal to but not higher than 2.
t 2 E + 0,035 R L f y
5 is a coefficient whose value is determined by figure 4 in Standard UNE-EN 40-3-3 using the
appropriate values of R/L and .
is the semi-angle of the door aperture (in degrees).
g is the coefficient which for circular sections is 1.0.
L is the effective length of the aperture and has a value of (a-0.43N) (in mm).
a is the total length of the aperture (in mm).
N is the radius of the round part of the aperture (in mm) (maximum value: half the width of the
door aperture).
9
JOAN MULET, S.L.
Z py = F R 2 t (1 + cos )
Reinforcement type 3: this consists of 2 sheet metal plates welded on each side of the door with
a length and thickness defined as e in each case.
10
JOAN MULET, S.L.
where:
5 is as defined earlier.
2 E
6 is a coefficient whose value is equal to for reinforcements type 1, 2, 3,
2 E + f y ( L / ) 2
11
JOAN MULET, S.L.
c) The total shear strength (in N) of all mountings, for each S length divided by fy.
d) The total shear strength (in N) of all mountings, for each C length divided by fy.
S is the connection length of the end of the reinforcement of the door aperture (in mm).
C is the length of the upper and lower halves of the straight edge of the door aperture (in mm).
Zpnr is the plastic modulus of the section, including the effective reinforcement of the door
aperture, around the plastic neutral axis n-n (in mm3).
Zpyr is the plastic modulus of the section, including the effective reinforcement of the door
aperture, around the plastic neutral axis n-n (in mm3).
90 B x
Z pnr = 2 R 2 t 2 cos sen + B x cos
2
Z pyr = 2 R 2 t (1 + cos + B y sen )
where:
Ac mox
Bx =
R t mx
Ac moy
By =
R t my
mox is the distance between the centroid point of the actual reinforcement of the door and
the x-x axis measured perpendicularly to the axis (in mm)
moy is the distance between the centroid point of the actual reinforcement of the door and
the y-y axis measured perpendicularly to the axis (in mm)
mx is the distance between the centre of the wall of the pole or lighting column at the
edge of the aperture and the x-x axis measured perpendicularly to the axis (in mm).
my is the distance between the centre of the wall of the pole or lighting column at the
edge of the aperture and the y-y axis measured perpendicularly to the axis (in mm).
Reinforcement type 5: this consists of a truncated conical tube positioned inside the lighting
column in the length and width defined for each case. The tube will be tightly adjusted (force of
pressure) to the exterior surround (see diagram).
12
JOAN MULET, S.L.
a = 300 mm
l 500 mm
13
JOAN MULET, S.L.
The bending strength with reinforcement type 5 will be the result of the algebraic addition of
the interior and exterior bending strength of the tube, on condition that the interior tube is
adjusted tightly to the exterior surround. The formulas in section B. Standard non-reinforced
open cross-section will be used.
The torsional strength should be the strength of the external cross-section of the pole or lighting
column only and the formula described in section B. Standard non-reinforced open cross-
section will be used.
The strength of the pole should be regarded as acceptable if all the critical cross-sections fulfil the
following:
Mx M y Tp
+ + 1
M ux M uy Tu
where:
Mx, My, and Mp are the bending points around the orthogonal axes x-x and y-y.
Tp is the torsional moment in lighting columns or poles with asymmetric arm/light devices.
Mux, Muy, Mup and Tu are the bending and torsional moments described earlier.
If any of the critical sections does not fulfil the above conditions, a possible reinforcement to be
fitted to them will be studied and the bending and torsional moments for the reinforced sections
will be calculated.
The horizontal and vertical distortions of the connection of the lights under the effect of the design
loads will be studied.
Horizontal distortion occurs through the bending and/or torsion of the shaft of the lighting column
under the effects of wind on the pole and lights. Vertical distortion is caused by the shaft of the
lighting column or pole bending under the effect of the mass of the outreach arm that separates the
vertical shaft from the light.
14
JOAN MULET, S.L.
Using the CYPE computer programme, the vertical and horizontal distortions at the target points
are obtained. This value should comply with one of the following categories:
For the purposes of this calculation, (h) is the height of the pole (in m) and (w) is the arm outreach
(in m).
Start of arm
3 102.14 4 0.193
outreach
* Reinforcement type 3 (2 sheet metal plates on each side of door; e=4 mm)
15
JOAN MULET, S.L.
16
JOAN MULET, S.L.
17
JOAN MULET, S.L.
* Reinforcement type 3 (2 sheet metal plates on each side of door; e=4 mm) + type 5 (interior
truncated conical tube; e=4 mm)
18
JOAN MULET, S.L.
* Reinforcement type 3 (2 sheet metal plates on each side of door; e=4 mm)
(1)
Reinforcement type 5 (interior truncated conical tube; e=4 mm)
(2)
Reinforcement type 3 (2 sheet metal plates one each side of door; e=5 mm) + type 5 (interior
truncated conical tube e=5 mm)
19
JOAN MULET, S.L.
* Reinforcement type 3 (2 sheet metal plates on each side of door; e=4 mm) + type 5 (interior
truncated conical tube e=4 mm)
20
JOAN MULET, S.L.
(1)
Reinforcement type 5 (interior truncated conical tube e=4 mm)
(2)
Reinforcement type 3 (2 sheet metal plates on each side of door; e=4 mm) + type 5 (interior
truncated conical tube e=4 mm).
21
JOAN MULET, S.L.
(1)
Reinforcement type 5 (interior truncated conical tube e=4 mm)
(2)
Reinforcement type 5 (interior truncated conical tube e=4 mm)
* Reinforcement type 3 (2 sheet metal plates on each side of door; e=4 mm)
With regard to distortions, the vertical and horizontal distortions at the connection points of the
lights to the pole are described in the attached tables. The arm outreach length of the FUL-7\10 is
0.05 m for the first light, 0.32 m for the second and 0.61 m for the third; the FUL-7\9 is 3.43m for
the first light, 4.17m for the second and 4.87m for the third. They are both 7 m high.
The arm outreach length of the FUL-9 is 2.3 m for the first light, 2.81 m for the second and 3.32 m
for the third; the FUL-10 is 0.05m for the first and second lights and 0.3m for the third, 0.48m for
the fourth and 0.66 m for the fifth; and the FUL-12 does not have any arms. Their heights are 9, 10
and 12 m respectively. All the lighting columns conform to the three categories.
22
JOAN MULET, S.L.
23
JOAN MULET, S.L.
24
JOAN MULET, S.L.
25
JOAN MULET, S.L.
26
JOAN MULET, S.L.
With regard to vertical distortion, the results for the different lighting columns are given below:
27
JOAN MULET, S.L.
For the FUL-7\10, the maximum vertical distortion is 0.015. As can be seen, this distortion is not
exceeded at any point.
For the FUL-7\9, the maximum vertical distortion is 0.122. As can be seen, in the third light both
materials exceed the vertical distortion by 3 cm; by adding a ring of equal thickness to the lighting
column and 1,000 mm long to the lower part of the column, the vertical distortion is reduced at the
upper end, thus complying with the maximum vertical distortion.
28
JOAN MULET, S.L.
For the FUL-9, the maximum vertical distortion is 0.078. As can be seen, this distortion is not
exceeded at any point.
29
JOAN MULET, S.L.
For the FUL-10, the maximum vertical distortion is 0.015. As can be seen, this distortion is not
exceeded at any point.
As the FUL-12 does not have any arms, the vertical distortion check does not apply.
On evaluating the location of the lighting columns under study in this project, the conditions under
which these results were obtained will be taken into account. Any variation in the location
conditions that may determine a wind pressure higher than the values obtained in this project will
entail a new study on the limit state of the column.
It is anticipated that the location conditions that have been taken into account for the calculation
will be fulfilled in the majority of cases, as the plan is that these public street light columns will be
installed in seafront promenade areas.
30
JOAN MULET, S.L.
The support for the lighting columns will consist of concrete base plates embedded in the ground.
To calculate their size, the bending moment, shearing force and normal force transmitted will all be
taken into account.
For a minimum terrain stress (4.41 lbf/cm2), we obtained the following sizes for the minimum base
plates using the CYPE programme (which are given for each lighting column model) under the
same conditions for which the lighting column was calculated.
31
JOAN MULET, S.L.
Due to the conical shape of the pole, it is divided into seven sections of different diameters.
q(z) = fCe(z)q(10)
where:
= 1-001(7m) = 093
Calculation of :
The value of this coefficient is obtained from the table in the Annex based on vibration time (T)
and the column material. The vibration time (T) depends on the maximum movement (d) at the tip,
according to the equation:
T = 2d^1/2
The value (d) depends on the loads applied to the lighting column, so a recurrent calculation will
need to be made.
Finally, a movement in the tip of 0.26 metres was obtained, for which the vibration time is 0.93
seconds. For this value (T) and a metal column, a dynamic behaviour coefficient () of 1.39 is
obtained.
32
JOAN MULET, S.L.
The exposure coefficient Ce(z) depends on the height above ground of the column and the category
of the terrain. For a height of 7m on terrain category I, a value of 2.57 is obtained. This value is
obtained from table 2 of Standard EN 40-3-1.
This depends on the benchmark speed under consideration, which in this case is 124.27 miles/h.
Once this has been obtained, the force per lineal metre exerted on the pole can be calculated:
F = q(z)cDext
where
c is the shape coefficient obtained from the graph in Standard UNE-EN 40-3-1, which uses the
Reynolds number and the shape of the pole.
Re = (vD)/
33
JOAN MULET, S.L.
Where
Due to the conical shape of the pole it is divided into 9 sections of different diameters.
q(z) = fCe(z)q(10)
where:
= 1-001(9m) = 091
Calculation of :
The value of this coefficient is obtained from the table in the Annex based on the vibration time (T)
and the column material. The vibration time (T) depends on the maximum movement of the tip (d),
according to the equation:
T = 2d^1/2
The value (d) depends on the loads applied to the lighting column, for which a recurrent calculation
needs to be made.
34
JOAN MULET, S.L.
Finally, a movement of the tip of 0.56 metres is obtained, for which the vibration time is 1.36
seconds. For this (T) value and a metal column, a dynamic behaviour coefficient () of 1.54 is
obtained.
The exposure coefficient Ce(z) depends on the height of the pole above ground and the category of
terrain. For a height of 9m and terrain category I, a value of 2.71 is obtained. This value is obtained
from table 2 in Standard EN 40-3-1.
This depends on the benchmark speed under consideration, which in this case is 124.27 miles/h.
Once this has been obtained, the force per lineal metre exerted on the pole can be calculated:
F = q(z)cDext
where
c is the shape coefficient obtained from the graph in Standard UNE-EN 40-3-1, which uses the
Reynolds number and the shape of the pole.
35
JOAN MULET, S.L.
Re = (vD)/
Where
Calculations for the other lighting columns followed the same procedure.
The values obtained are presented on the following pages.
This calculation was done based on Standard NBE AE-88, applying the wind coefficient given in
the standard multiplied by the wind pressure obtained from the same standard.
The force will depend upon the shape of the projection, the dynamic wind pressure and the wind
coefficient (c).
For a dynamic wind pressure of 425.50 lbf/m2 (wind speed of 124.27 miles per hour), the
following pressure values on each surface area have been obtained:
WIND
DIRECTION
36
JOAN MULET, S.L.
The vertical and horizontal forces exerted on the lighting column from the wind are as follows:
For the purpose of the calculation, 35 lbf will be taken for the horizontal component and 5.5 lbf for
the vertical component.
It is very possible that there will be a vertical upward push on the outreach, but as this would be
favourable it will not be taken into account.
Having calculated the wind forces exerted on the column and lights, and taking into account their
weights, the structural calculations are made with the help of the CYPE computer programme.
The results obtained can be seen in the following pages, which show the study of the critical
section.
37
1
ndice
Pgina 1
Metal 3D
Nombre Obra: ful7_10inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Inox i galva e=4mm tipus I 200Km/h
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.007 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.840 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.066 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.024 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.840 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.840 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.066 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.066 - 0.000 0.000 -1.000
3/2 1 (PP 1) Uniforme 0.008 Tn/m - - - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 0.334 - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.028 Tn/m - - - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.016 Tn - 0.334 - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 0.334 - 0.000 0.000 -1.000
4/3 1 (PP 1) Uniforme 0.010 Tn/m - - - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.031 Tn/m - - - 0.000 -1.000 0.000
5/4 1 (PP 1) Uniforme 0.011 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.034 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.012 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.038 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.013 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.038 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.015 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.038 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: ful7_10inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Inox i galva e=4mm tipus I 200Km/h
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: ful7_10inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Inox i galva e=4mm tipus I 200Km/h
Pgina 4
Metal 3D
Nombre Obra: ful7_10inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Inox i galva e=4mm tipus I 200Km/h
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.3223 12.40 0.000 -0.0269 0.0000 -0.1033 0.0000 -0.0505 0.0000
3/2 0.7941 30.54 0.000 -0.0844 0.0000 -0.1590 0.0000 -0.1728 0.0000
4/3 1.1771 45.27 0.000 -0.1185 0.0000 -0.1881 0.0000 -0.3392 0.0000
5/4 1.4934 57.44 0.000 -0.1304 0.0000 -0.2363 0.0000 -0.5517 0.0000
6/5 1.7698 68.07 0.000 -0.1441 0.0000 -0.2898 0.0000 -0.8148 0.0000
7/6 2.0157 77.53 0.000 -0.1596 0.0000 -0.3432 0.0000 -1.1314 0.0000
8/7 2.2369 86.03 0.000 -0.1766 0.0000 -0.3966 0.0000 -1.5013 0.0000
Pgina 5
1
ndice
Pgina 1
Metal 3D
Nombre Obra: ful7_10corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Corten e=5mm tipus I 200Km/h
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.009 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.840 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.066 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.024 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.840 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.840 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.066 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.066 - 0.000 0.000 -1.000
3/2 1 (PP 1) Uniforme 0.010 Tn/m - - - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 0.334 - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.028 Tn/m - - - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.016 Tn - 0.334 - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 0.334 - 0.000 0.000 -1.000
4/3 1 (PP 1) Uniforme 0.012 Tn/m - - - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.031 Tn/m - - - 0.000 -1.000 0.000
5/4 1 (PP 1) Uniforme 0.014 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.034 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.015 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.038 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.017 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.038 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.018 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.038 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: ful7_10corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Corten e=5mm tipus I 200Km/h
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: ful7_10corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Corten e=5mm tipus I 200Km/h
Pgina 4
Metal 3D
Nombre Obra: ful7_10corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/10 Corten e=5mm tipus I 200Km/h
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.2712 10.43 0.000 -0.0289 0.0000 -0.1042 0.0000 -0.0511 0.0000
3/2 0.6615 25.44 0.000 -0.0889 0.0000 -0.1597 0.0000 -0.1738 0.0000
4/3 0.9737 37.45 0.000 -0.1259 0.0000 -0.1882 0.0000 -0.3403 0.0000
5/4 1.2300 47.31 0.000 -0.1409 0.0000 -0.2364 0.0000 -0.5529 0.0000
6/5 1.4530 55.88 0.000 -0.1582 0.0000 -0.2900 0.0000 -0.8162 0.0000
7/6 1.6508 63.49 0.000 -0.1775 0.0000 -0.3434 0.0000 -1.1329 0.0000
8/7 1.8284 70.32 0.000 -0.1988 0.0000 -0.3968 0.0000 -1.5030 0.0000
Pgina 5
Bcul cilndric FUL 7_10
MODEL: FUL-7\10
Wind pressure as per UNE -EN 40-3-1
Input data
Benchmark wind speed 200 Km/h (124,27 miles/h) Forecast for return period of 25 years Cs = 0,959166305
Height in metres 7 Benchmark dynamic pressure daN/m2 177,4691358 398,8261537 lbf/m2
No. of sections 7 Air density 1,25 kg/m3
Type of column section circular
Coeff. column size 0,93 Max. distortion predicted at tip 0,26 metres
Coeff. dynamic behaviour 1,39 For a forecast vibration period of 0,928021551 seconds
Coeff. topography 1
Coeff. exposure 2,57 For location of light in Terrain Cat. 1
Wind
Ext. diam. mm Exposure pressure Re*10^5 Shape Force daN/m Force Tn/m Force lbf/m
coeff. (daN/m2) coeff.
165 1,88 431,298981 8,32 0,57 40,564 0,04135 91,1587
152,43 1,88 431,298981 7,69 0,56 36,816 0,03753 82,7358
139,86 2,09 479,475995 7,44 0,56 37,553 0,03828 84,3918
127,29 2,35 539,123727 7,18 0,55 37,743 0,03847 84,8187
114,71 2,37 543,712014 6,50 0,54 33,681 0,03433 75,6904
102,14 2,48 568,947593 5,92 0,53 30,800 0,03140 69,2177
89,57 2,57 589,594884 5,28 0,52 27,462 0,02799 61,7145
77 2,57 589,594884 4,54 0,51 23,153 0,02360 52,0326
1/11
Bcul cilndric FUL 7_10
Verifications
Mx/Mux 0,62132097
My/Muy 0
Tp/Tu 0
Total 0,62132097 1 The cross-section conforms
2/11
Bcul cilndric FUL 7_10
Verifications
Mx/Mux 0,48414621
My/Muy 0
Tp/Tu 0
Total 0,48414621 1 The cross-section conforms
3/11
Bcul cilndric FUL 7_10
Verifications
Mx/Mux 0,35058088
My/Muy 0
Tp/Tu 0
Total 0,35058088 1 The cross-section conforms
4/11
Bcul cilndric FUL 7_10
5/11
Bcul cilndric FUL 7_10
6/11
Bcul cilndric FUL 7_10
7/11
Bcul cilndric FUL 7_10
Verifications
Mx/Mux 0,19271512
My/Muy 0
Tp/Tu 0
Total 0,19271512 1 The cross-section conforms
8/11
Bcul cilndric FUL 7_10
Verifications
Mx/Mux 0,15016762
My/Muy 0
Tp/Tu 0
Total 0,15016762 1 The cross-section conforms
9/11
Bcul cilndric FUL 7_10
Verifications
Mx/Mux 0,86316157
My/Muy 0
Tp/Tu 0
Total 0,86316157 1 The cross-section conforms
10/11
Bcul cilndric FUL 7_10
Summary
The column does not conform in any of the critical sections; the sections that do not conform need to be reinforced
11/11
MODEL: FUL 7\10
CROSS-SECTION 2: UPPER EDGE OF DOOR APERTURE 1 (WITH REINFORCEMENT TYPE 3)
NDICE
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 1
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:09/05/06
I ANGLES\CLCULS\FUL 7\ful7_10corten TIPUS I 200Km_h.EM3
Ful 7/10 Corten e=5mm tipus I 200Km/h
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 2
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:09/05/06
I ANGLES\CLCULS\FUL 7\ful7_10corten TIPUS I 200Km_h.EM3
Ful 7/10 Corten e=5mm tipus I 200Km/h
Pgina 3
1
ndice
Pgina 1
Metal 3D
Nombre Obra: f7_9inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Inox i galva e=4mm tipus I 200Km/h
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.007 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 1.916 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 1.059 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.293 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.025 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 1.916 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 1.916 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 1.059 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 1.059 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.293 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.293 - 0.000 -1.000 0.000
3/2 1 (PP 1) Uniforme 0.009 Tn/m - - - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.032 Tn/m - - - 0.000 -1.000 0.000
4/3 1 (PP 1) Uniforme 0.011 Tn/m - - - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.037 Tn/m - - - 0.000 -1.000 0.000
5/4 1 (PP 1) Uniforme 0.012 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.042 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.014 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.049 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.016 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.050 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.018 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.050 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: f7_9inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Inox i galva e=4mm tipus I 200Km/h
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: f7_9inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Inox i galva e=4mm tipus I 200Km/h
Pgina 4
Metal 3D
Nombre Obra: f7_9inox TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Inox i galva e=4mm tipus I 200Km/h
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 1.1254 43.28 0.000 0.0832 0.0000 -0.1613 0.0000 -0.1777 0.0000
3/2 2.2699 87.31 0.000 0.1305 0.0000 -0.2305 0.0000 -0.5589 0.0000
4/3 2.6279 101.07 0.000 0.0691 0.0000 -0.3234 0.0000 -0.9298 0.0000
5/4 2.7355 105.21 0.000 -0.0219 0.0000 -0.3938 0.0000 -1.3166 0.0000
6/5 2.7671 106.43 0.000 -0.1206 0.0000 -0.4488 0.0000 -1.7335 0.0000
7/6 2.7994 107.67 0.000 -0.1459 0.0000 -0.5170 0.0000 -2.2169 0.0000
8/7 2.8394 109.21 0.000 -0.1658 0.0000 -0.5874 0.0000 -2.7706 0.0000
Pgina 5
1
ndice
Pgina 1
Metal 3D
Nombre Obra: f7_9corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Corten e=5mm tipus I 200Km/h
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.009 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 1.916 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 1.059 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.293 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.025 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 1.916 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 1.916 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 1.059 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 1.059 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.293 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.293 - 0.000 -1.000 0.000
3/2 1 (PP 1) Uniforme 0.011 Tn/m - - - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.032 Tn/m - - - 0.000 -1.000 0.000
4/3 1 (PP 1) Uniforme 0.013 Tn/m - - - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.037 Tn/m - - - 0.000 -1.000 0.000
5/4 1 (PP 1) Uniforme 0.015 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.042 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.018 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.049 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.020 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.050 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.022 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.050 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: f7_9corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Corten e=5mm tipus I 200Km/h
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: f7_9corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Corten e=5mm tipus I 200Km/h
Pgina 4
Metal 3D
Nombre Obra: f7_9corten TIPUS I 200Km_h Fecha:11/05/06
Ful 7/9 Corten e=5mm tipus I 200Km/h
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.9602 36.93 0.000 0.0811 0.0000 -0.1654 0.0000 -0.1823 0.0000
3/2 1.9279 74.15 0.000 0.1256 0.0000 -0.2385 0.0000 -0.5748 0.0000
4/3 2.2167 85.26 0.000 0.0586 0.0000 -0.3315 0.0000 -0.9545 0.0000
5/4 2.2929 88.19 0.000 -0.0378 0.0000 -0.3999 0.0000 -1.3471 0.0000
6/5 2.3035 88.60 0.000 -0.1416 0.0000 -0.4516 0.0000 -1.7665 0.0000
7/6 2.3183 89.16 0.000 -0.1716 0.0000 -0.5195 0.0000 -2.2523 0.0000
8/7 2.3421 90.08 0.000 -0.1967 0.0000 -0.5902 0.0000 -2.8085 0.0000
Pgina 5
Bcul cilndric FUL 7_9
MODEL: FUL-7\9
Wind pressure as per UNE -EN 40-3-1
Input data
Benchmark wind speed 200 Km/h (124,27 miles/h) Forecast for return period of 25 years Cs = 0,959166305
Heigth in metres 7 Benchmark dynamic pressure daN/m2 177,4691358 398,8261537 lbf/m2
N of sections 7 Air density 1,25 kg/m3
Type of column section circular
Coeff. Column size 0,93 Max. distortion predicted at tip 0,41 metres
Coeff. dynamic behaviour 1,48 For a forecast vibration period of 1,165368611 seconds
Coeff. Topography 1
Coeff. of exposure 2,57 For location of light in Terrain Cat. 1
Wind
Ext. diam. mm Exposure pressure Re*10^5 Shape Force daN/m Force Tn/m Force lbf/m
coeff. (daN/m2) coeff.
200 1,88 459,224815 10,09 0,6 55,107 0,05617 123,842
182,43 1,88 459,224815 9,20 0,59 49,428 0,05038 111,079
164,86 2,09 510,521204 8,77 0,58 48,815 0,04976 109,701
147,29 2,35 574,031019 8,31 0,57 48,192 0,04912 108,301
129,71 2,37 578,916389 7,35 0,55 41,302 0,04210 92,817
112,14 2,48 605,785926 6,50 0,54 36,685 0,03740 82,441
94,57 2,57 627,770093 5,58 0,53 31,466 0,03208 70,713
77 2,57 627,770093 4,54 0,51 24,653 0,02513 55,402
1/11
Bcul cilndric FUL 7_9
Verifications
Mx/Mux 0,78340562
My/Muy 0
Tp/Tu 0
Total 0,78340562 1 The cross-section conforms
2/11
Bcul cilndric FUL 7_9
Verifications
Mx/Mux 0,63768561
My/Muy 0
Tp/Tu 0
Total 0,63768561 1 The cross-section conforms
3/11
Bcul cilndric FUL 7_9
Geometric parameters of the different sections
Input data in mm Ext. diameter Thickness Density Ultimate limit state
Values in m m 200 5 0,785 Coeff. permanent loads 1,2
Average radius 97,5 Coeff variable loads 1,4
Section cm2 30,631
Weight Kg/m 24,045
Inertia moment cm4 1456,868
Moment of resistance cm3 145,687
Plasticity modulus cm3 190,125
Turning radius cm 6,897
Torsional inertia cm4 2913,736 "c"
Shape coeff. (N de Reynolds*10^5) 10,09 0,6
Pressure daN/m 55,107
Pressure Tn/m 0,05617
lbf/m 123,84184
Verifications
Mx/Mux 0,44095786
My/Muy 0
Tp/Tu 0
Total 0,44095786 1 The cross-section conforms
4/11
Bcul cilndric FUL 7_9
5/11
Bcul cilndric FUL 7_9
6/11
Bcul cilndric FUL 7_9
Geometric parameters of the different sections
Input data in mm Ext. diameter Thickness Density Width of gap
Values in m m 185,06 5 0,785 150 Degrees Radians
Section cm2 28,284 Angle 54,148 0,945
Weight Kg/m 22,203 Angle 1 125,852 2,197
Inertia moment cm4 1147,224 Average radius 90,032 mm
Moment of resistance cm3 123,981 C1 33,222 mm
Plasticity modulus cm3 162,116 Inertia Z 410,005 cm4
Turning radius cm 6,369 Inertia X 974,719 cm4
Torsional inertia cm4 2294,449 "c" Section 19,776 cm2
Shape coeff. (N de Reynolds*10^5) 9,34 0,59
Pressure daN/m 50,142 Ultimate limit state
Pressure Tn/m 0,051112952 Coeff. permanent loads 1,2
lbf/m 112,68361 Coeff. variable loads 1,4
7/11
Bcul cilndric FUL 7_9
Verifications
Mx/Mux 0,68985087
My/Muy 0
Tp/Tu 0
Total 0,68985087 1 The cross-section conforms
8/11
Bcul cilndric FUL 7_9
Verifications
Mx/Mux 0,53754614
My/Muy 0
Tp/Tu 0
Total 0,53754614 1 The cross-section conforms
9/11
Bcul cilndric FUL 7_9
Geometric parameters of the different sections
Input data in mm Ext. diameter Thickness Density Ultimate limit state
Values in m m 147,29 5 0,785 Coeff. permanent loads 1,2
Average radius 71,14285714 Coeff variable loads 1,4
Section cm2 22,350
Weight Kg/m 17,545
Inertia moment cm4 566,305
Moment of resistance cm3 76,899
Plasticity modulus cm3 101,226
Turning radius cm 5,034
Torsional inertia cm4 1132,611 "c"
Shape coeff. (N de Reynolds*10^5) 8,34 0,54
Pressure daN/m 48,181
Pressure Tn/m 0,04911
lbf/m 108,27654
Verifications
Mx/Mux 0,39818086
My/Muy 0
Tp/Tu 0
Total 0,39818086 1 The cross-section conforms
10/11
Bcul cilndric FUL 7_9
Summary
The column does not conform in any of the critical sections; the sections that do not conform need to be reinforced
11/11
MODEL: FUL 7\9
CROSS-SECTION 2: UPPER EDGE OF DOOR APERTURE 1 (WITH REINFORCEMENT TYPE 5)
NDICE
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 1
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:09/05/06
I ANGLES\CLCULS\FUL 9\f2 5_200.EM3
FUL-9 200km/h e=5mm PROJ GRAN
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 2
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:09/05/06
I ANGLES\CLCULS\FUL 9\f2 5_200.EM3
FUL-9 200km/h e=5mm PROJ GRAN
Pgina 3
1
10
Obra: f2 4_200
Descripcin: FUL-9 200km/h e=4mm PROJ GRAN
Norma de acero laminado: EA-95 (MV103)
Norma de acero conformado: EA-95 (MV110)
Vista: 3D
Escala: 1: 50
Metal 3D
Nombre Obra: f2 4_200 Fecha:11/05/06
FUL-9 200km/h e=4mm PROJ GRAN
ndice
Pgina 1
Metal 3D
Nombre Obra: f2 4_200 Fecha:11/05/06
FUL-9 200km/h e=4mm PROJ GRAN
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.007 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.772 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.027 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.772 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.772 - 0.000 0.000 -1.000
3/2 1 (PP 1) Uniforme 0.009 Tn/m - - - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 1.003 - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 0.115 - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.032 Tn/m - - - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 0.115 - 0.000 0.000 -1.000
3/2 2 (V 1) Puntual 0.016 Tn - 1.003 - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 1.003 - 0.000 0.000 -1.000
3/2 2 (V 1) Puntual 0.016 Tn - 0.115 - 0.000 -1.000 0.000
4/3 1 (PP 1) Uniforme 0.010 Tn/m - - - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.036 Tn/m - - - 0.000 -1.000 0.000
5/4 1 (PP 1) Uniforme 0.011 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.041 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.013 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.044 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.014 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.049 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.015 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.048 Tn/m - - - 0.000 -1.000 0.000
9/8 1 (PP 1) Uniforme 0.017 Tn/m - - - 0.000 0.000 -1.000
9/8 2 (V 1) Uniforme 0.048 Tn/m - - - 0.000 -1.000 0.000
10/9 1 (PP 1) Uniforme 0.018 Tn/m - - - 0.000 0.000 -1.000
10/9 2 (V 1) Uniforme 0.052 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: f2 4_200 Fecha:11/05/06
FUL-9 200km/h e=4mm PROJ GRAN
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: f2 4_200 Fecha:11/05/06
FUL-9 200km/h e=4mm PROJ GRAN
Pgina 4
Metal 3D
Nombre Obra: f2 4_200 Fecha:11/05/06
FUL-9 200km/h e=4mm PROJ GRAN
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.3476 14.48 0.000 -0.0025 0.0000 -0.0829 0.0000 -0.0551 0.0000
3/2 0.9925 41.35 0.000 -0.0188 0.0000 -0.2114 0.0000 -0.2234 0.0000
Pgina 5
Metal 3D
Nombre Obra: f2 4_200 Fecha:11/05/06
FUL-9 200km/h e=4mm PROJ GRAN
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
4/3 1.6529 68.87 0.000 -0.0009 0.0000 -0.2729 0.0000 -0.5026 0.0000
5/4 2.1746 90.61 0.000 0.0194 0.0000 -0.3430 0.0000 -0.8576 0.0000
6/5 2.4502 102.09 0.000 -0.1377 0.0000 -0.3868 0.0000 -1.2120 0.0000
7/6 2.6954 112.31 0.000 -0.1498 0.0000 -0.4619 0.0000 -1.6380 0.0000
8/7 2.9167 121.53 0.000 -0.1639 0.0000 -0.5357 0.0000 -2.1387 0.0000
9/8 3.1170 129.88 0.000 -0.1798 0.0000 -0.6096 0.0000 -2.7135 0.0000
10/9 3.3046 137.69 0.000 -0.1969 0.0000 -0.6897 0.0000 -3.3657 0.0000
Pgina 6
1
10
Obra: f2 5_200
Descripcin: FUL-9 200km/h e=5mm PROJ GRAN
Norma de acero laminado: EA-95 (MV103)
Norma de acero conformado: EA-95 (MV110)
Vista: 3D
Escala: 1: 50
Metal 3D
Nombre Obra: f2 5_200 Fecha:11/05/06
FUL-9 200km/h e=5mm PROJ GRAN
ndice
Pgina 1
Metal 3D
Nombre Obra: f2 5_200 Fecha:11/05/06
FUL-9 200km/h e=5mm PROJ GRAN
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.009 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.772 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.027 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.772 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.772 - 0.000 0.000 -1.000
3/2 1 (PP 1) Uniforme 0.011 Tn/m - - - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 1.003 - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 0.115 - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.032 Tn/m - - - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 0.115 - 0.000 0.000 -1.000
3/2 2 (V 1) Puntual 0.016 Tn - 1.003 - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 1.003 - 0.000 0.000 -1.000
3/2 2 (V 1) Puntual 0.016 Tn - 0.115 - 0.000 -1.000 0.000
4/3 1 (PP 1) Uniforme 0.012 Tn/m - - - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.036 Tn/m - - - 0.000 -1.000 0.000
5/4 1 (PP 1) Uniforme 0.014 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.041 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.016 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.044 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.017 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.049 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.019 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.048 Tn/m - - - 0.000 -1.000 0.000
9/8 1 (PP 1) Uniforme 0.021 Tn/m - - - 0.000 0.000 -1.000
9/8 2 (V 1) Uniforme 0.048 Tn/m - - - 0.000 -1.000 0.000
10/9 1 (PP 1) Uniforme 0.022 Tn/m - - - 0.000 0.000 -1.000
10/9 2 (V 1) Uniforme 0.052 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: f2 5_200 Fecha:11/05/06
FUL-9 200km/h e=5mm PROJ GRAN
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: f2 5_200 Fecha:11/05/06
FUL-9 200km/h e=5mm PROJ GRAN
Pgina 4
Metal 3D
Nombre Obra: f2 5_200 Fecha:11/05/06
FUL-9 200km/h e=5mm PROJ GRAN
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.2935 8.15 0.000 -0.0048 0.0000 -0.0842 0.0000 -0.0558 0.0000
3/2 0.8329 23.14 0.000 -0.0237 0.0000 -0.2142 0.0000 -0.2265 0.0000
Pgina 5
Metal 3D
Nombre Obra: f2 5_200 Fecha:11/05/06
FUL-9 200km/h e=5mm PROJ GRAN
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
4/3 1.3821 38.39 0.000 -0.0090 0.0000 -0.2775 0.0000 -0.5100 0.0000
5/4 1.8131 50.36 0.000 0.0078 0.0000 -0.3497 0.0000 -0.8715 0.0000
6/5 2.0318 56.44 0.000 -0.1550 0.0000 -0.3883 0.0000 -1.2273 0.0000
7/6 2.2255 61.82 0.000 -0.1716 0.0000 -0.4638 0.0000 -1.6549 0.0000
8/7 2.4005 66.68 0.000 -0.1906 0.0000 -0.5380 0.0000 -2.1578 0.0000
9/8 2.5591 71.09 0.000 -0.2119 0.0000 -0.6124 0.0000 -2.7352 0.0000
10/9 2.7080 75.22 0.000 -0.2348 0.0000 -0.6930 0.0000 -3.3903 0.0000
Pgina 6
MODEL: FUL-10
Wind pressure as per UNE -EN 40-3-1
Input data
Benchmark wind speed 200 Km/h (124,27 milles/h) Forecast for return period of 25 years Cs = 0,959166305
Height in metres 10 Benchmark dynamic pressure daN/m2 177,4691358 398,8261537 lbf/m2
No. of sections 10 Air density 1,25 kg/m3
Type of column section circular
Coeff. column size 0,9 Max. distortion predicted at tip 0,76 metres
Coeff. dynamic behaviour 1,7 For a forecast vibration period of 1,743559577 seconds
Coeff. topography 1
Coeff. exposure 2,78 For location of light in Terrain Cat. 1
Wind
Ext. diam. mm Exposure pressure Re*10^5 Shape Force daN/m Force Tn/m Force lbf/m
coeff. (daN/m2) coeff.
200 1,88 510,472222 10,09 0,6 61,257 0,06244 137,6620
187,70 1,88 510,472222 9,47 0,59 56,531 0,05763 127,0425
175,40 1,88 510,472222 8,85 0,58 51,931 0,05294 116,7053
163,10 2,09 567,493056 8,68 0,57 52,758 0,05378 118,5633
150,80 2,35 638,090278 8,51 0,57 54,848 0,05591 123,2591
138,50 2,37 643,520833 7,84 0,56 49,911 0,05088 112,1660
126,20 2,48 673,388889 7,31 0,55 46,740 0,04765 105,0386
113,90 2,57 697,826389 6,72 0,55 43,715 0,04456 98,2414
101,60 2,64 716,833333 6,07 0,53 38,600 0,03935 86,7458
89,30 2,71 735,840278 5,41 0,52 34,169 0,03483 76,7890
77 2,78 754,847222 4,72 0,51 29,643 0,03022 66,6163
CROSS-SECTION 1: FIXATION POINT OF COLUMN OR POLE
Verifications
Mx/Mux 1,10683255
My/Muy 0
Tp/Tu 0
Total 1,10683255 1 The cross-section does not conform
GALVANIZED STEEL AP-11
Verifications
Mx/Mux 0,90095242
My/Muy 0
Tp/Tu 0
Total 0,90095242 1 The cross-section conforms
Verifications
Mx/Mux 0,61511109
My/Muy 0
Tp/Tu 0
Suma 0,61511109 1 The cross-section conforms
Verifications
Mx/Mux 0,27910582
My/Muy 0
Tp/Tu 0
Total 0,27910582 1 The cross-section conforms
Verifications
Mx/Mux 0,21748506
My/Muy 0
Tp/Tu 0
Total 0,21748506 1 The cross-section conforms
Geometric parameters of the different sections
Input data in mm Ext. diameter Thickness Density Ultimate limit state
Values in m m 107,75 5 0,785 Coeff. permanent loads 1,2
Average radius 51,375 Coeff variable loads 1,4
Section cm2 16,140
Weight Kg/m 12,670
Inertia moment cm4 213,503
Moment of resistance cm3 39,629
Plasticity modulus cm3 52,788
Turning radius cm 3,637
Torsional inertia cm4 427,006 "c"
Shape coeff. (N de Reynolds*10^5) 6,08 0,53
Pressure daN/m 40,937
Pressure Tn/m 0,04173
lbf/m 91,99668
Verifications
Mx/Mux 0,15949778
My/Muy 0
Tp/Tu 0
Total 0,15949778 1 The cross-section conforms
Summary
The column does not conform in any of the critical sections; the sections that do not conform need to be reinforced
MODEL: FUL 10
3
Zp 174845 mm
Mux=Muy=Mup 39964,57143 Nm
898123,2841 lbfcm
Verifications
0,632175383
1 1 Mx/(MuxW/OUT REINFORCEMENT + Mux REINFORCEMENT) 0,514388362
My/(MuySW/OUT REINFORCEMENT + Muy REINFORCEMENT) 0
Tp/Tu 0
Total 0,514388362 1
CROSS-SECTION 2: UPPER EDGE OF DOOR APERTURE 1 (WITH REINFORCEMENT TYPE 3 + REINFORCEMENT TYPE 5)
Verifications
CROSS-SECTION 2: UPPER EDGE OF DOOR APERTURE 1 (WITH REINFORCEMENT TYPE 3 + REINFORCEMENT TYPE 5)
Verifications
NDICE
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 1
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:10/05/06
I ANGLES\CLCULS\FUL 10\f10_cort 200 NOU.EM3
FUL 10 CORTEN 200Km/h e=5mm LUMINARIA GRAN
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 2
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:10/05/06
I ANGLES\CLCULS\FUL 10\f10_cort 200 NOU.EM3
FUL 10 CORTEN 200Km/h e=5mm LUMINARIA GRAN
Pgina 3
1
xy: 1.00
xy: 1.00
2
xy: 1.00
xy: 1.00
3
xy: 1.00
xy: 1.00
4
xy: 1.00
xy: 1.00
5
xy: 1.00
xy: 1.00
6
xy: 1.00
xy: 1.00
7
xy: 1.00
xy: 1.00
8
xy: 1.00
xy: 1.00
9
xy: 1.00
xy: 1.00
10
xy: 1.00
xy: 1.00
11
ndice
Pgina 1
Metal 3D
Nombre Obra: f12ap11 200 NOU Fecha:11/05/06
FUL12 acer AP11 200Km/h e=4mm luminaria gran
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.008 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.843 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.145 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.037 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.843 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.145 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.843 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.145 - 0.000 0.000 -1.000
3/2 1 (PP 1) Uniforme 0.010 Tn/m - - - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 0.638 - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.044 Tn/m - - - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.016 Tn - 0.638 - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 0.638 - 0.000 0.000 -1.000
4/3 1 (PP 1) Uniforme 0.011 Tn/m - - - 0.000 0.000 -1.000
4/3 1 (PP 1) Puntual 0.021 Tn - 1.144 - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.050 Tn/m - - - 0.000 -1.000 0.000
4/3 2 (V 1) Puntual 0.016 Tn - 1.144 - 0.000 -1.000 0.000
4/3 2 (V 1) Puntual 0.003 Tn - 1.144 - 0.000 0.000 -1.000
5/4 1 (PP 1) Uniforme 0.013 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.057 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.014 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.063 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.016 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.066 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.017 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.071 Tn/m - - - 0.000 -1.000 0.000
9/8 1 (PP 1) Uniforme 0.019 Tn/m - - - 0.000 0.000 -1.000
9/8 2 (V 1) Uniforme 0.076 Tn/m - - - 0.000 -1.000 0.000
10/9 1 (PP 1) Uniforme 0.020 Tn/m - - - 0.000 0.000 -1.000
10/9 2 (V 1) Uniforme 0.073 Tn/m - - - 0.000 -1.000 0.000
11/10 1 (PP 1) Uniforme 0.022 Tn/m - - - 0.000 0.000 -1.000
11/10 2 (V 1) Uniforme 0.070 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: f12ap11 200 NOU Fecha:11/05/06
FUL12 acer AP11 200Km/h e=4mm luminaria gran
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: f12ap11 200 NOU Fecha:11/05/06
FUL12 acer AP11 200Km/h e=4mm luminaria gran
Pgina 4
Metal 3D
Nombre Obra: f12ap11 200 NOU Fecha:11/05/06
FUL12 acer AP11 200Km/h e=4mm luminaria gran
Pgina 5
Metal 3D
Nombre Obra: f12ap11 200 NOU Fecha:11/05/06
FUL12 acer AP11 200Km/h e=4mm luminaria gran
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.3280 12.62 0.000 -0.0678 0.0000 -0.1212 0.0000 -0.0672 0.0000
3/2 0.9508 36.57 0.000 -0.1067 0.0000 -0.2285 0.0000 -0.2788 0.0000
4/3 1.6253 62.51 0.000 -0.1471 0.0000 -0.3468 0.0000 -0.6399 0.0000
5/4 2.2027 84.72 0.000 -0.1585 0.0000 -0.4512 0.0000 -1.1205 0.0000
6/5 2.7175 104.52 0.000 -0.1714 0.0000 -0.5666 0.0000 -1.7336 0.0000
7/6 3.1849 122.50 0.000 -0.1862 0.0000 -0.6876 0.0000 -2.4890 0.0000
8/7 3.6144 139.01 0.000 -0.2026 0.0000 -0.8178 0.0000 -3.3957 0.0000
9/8 4.0153 154.43 0.000 -0.2206 0.0000 -0.9573 0.0000 -4.4649 0.0000
10/9 4.3875 168.75 0.000 -0.2415 0.0000 -1.0915 0.0000 -5.6988 0.0000
11/10 4.7268 181.80 0.000 -0.2652 0.0000 -1.2205 0.0000 -7.0913 0.0000
Pgina 6
1
xy: 1.00
xy: 1.00
2
xy: 1.00
xy: 1.00
3
xy: 1.00
xy: 1.00
4
xy: 1.00
xy: 1.00
5
xy: 1.00
xy: 1.00
6
xy: 1.00
xy: 1.00
7
xy: 1.00
xy: 1.00
8
xy: 1.00
xy: 1.00
9
xy: 1.00
xy: 1.00
10
xy: 1.00
xy: 1.00
11
ndice
Pgina 1
Metal 3D
Nombre Obra: f12cort NOU 200 Fecha:11/05/06
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
Cargas Direccin
Barras Hipt. Tipo
P1 P2 L1 (m) L2 (m) X Y Z
2/1 1 (PP 1) Uniforme 0.010 Tn/m - - - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.843 - 0.000 0.000 -1.000
2/1 1 (PP 1) Puntual 0.021 Tn - 0.145 - 0.000 0.000 -1.000
2/1 2 (V 1) Uniforme 0.037 Tn/m - - - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.843 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.016 Tn - 0.145 - 0.000 -1.000 0.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.843 - 0.000 0.000 -1.000
2/1 2 (V 1) Puntual 0.003 Tn - 0.145 - 0.000 0.000 -1.000
3/2 1 (PP 1) Uniforme 0.012 Tn/m - - - 0.000 0.000 -1.000
3/2 1 (PP 1) Puntual 0.021 Tn - 0.638 - 0.000 0.000 -1.000
3/2 2 (V 1) Uniforme 0.044 Tn/m - - - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.016 Tn - 0.638 - 0.000 -1.000 0.000
3/2 2 (V 1) Puntual 0.003 Tn - 0.638 - 0.000 0.000 -1.000
4/3 1 (PP 1) Uniforme 0.014 Tn/m - - - 0.000 0.000 -1.000
4/3 1 (PP 1) Puntual 0.021 Tn - 1.144 - 0.000 0.000 -1.000
4/3 2 (V 1) Uniforme 0.051 Tn/m - - - 0.000 -1.000 0.000
4/3 2 (V 1) Puntual 0.016 Tn - 1.144 - 0.000 -1.000 0.000
4/3 2 (V 1) Puntual 0.003 Tn - 1.144 - 0.000 0.000 -1.000
5/4 1 (PP 1) Uniforme 0.016 Tn/m - - - 0.000 0.000 -1.000
5/4 2 (V 1) Uniforme 0.057 Tn/m - - - 0.000 -1.000 0.000
6/5 1 (PP 1) Uniforme 0.018 Tn/m - - - 0.000 0.000 -1.000
6/5 2 (V 1) Uniforme 0.063 Tn/m - - - 0.000 -1.000 0.000
7/6 1 (PP 1) Uniforme 0.020 Tn/m - - - 0.000 0.000 -1.000
7/6 2 (V 1) Uniforme 0.067 Tn/m - - - 0.000 -1.000 0.000
8/7 1 (PP 1) Uniforme 0.021 Tn/m - - - 0.000 0.000 -1.000
8/7 2 (V 1) Uniforme 0.071 Tn/m - - - 0.000 -1.000 0.000
9/8 1 (PP 1) Uniforme 0.023 Tn/m - - - 0.000 0.000 -1.000
9/8 2 (V 1) Uniforme 0.076 Tn/m - - - 0.000 -1.000 0.000
10/9 1 (PP 1) Uniforme 0.025 Tn/m - - - 0.000 0.000 -1.000
10/9 2 (V 1) Uniforme 0.073 Tn/m - - - 0.000 -1.000 0.000
11/10 1 (PP 1) Uniforme 0.027 Tn/m - - - 0.000 0.000 -1.000
11/10 2 (V 1) Uniforme 0.070 Tn/m - - - 0.000 -1.000 0.000
2.- Desplazamientos
Pgina 2
Metal 3D
Nombre Obra: f12cort NOU 200 Fecha:11/05/06
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
3.- Esfuerzos
Pgina 3
Metal 3D
Nombre Obra: f12cort NOU 200 Fecha:11/05/06
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
Pgina 4
Metal 3D
Nombre Obra: f12cort NOU 200 Fecha:11/05/06
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
Pgina 5
Metal 3D
Nombre Obra: f12cort NOU 200 Fecha:11/05/06
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
4.- Tensiones
TENSIN MXIMA
Barras
TENS. (Tn/cm2) APROV. (%) Pos. (m) N (Tn) Ty (Tn) Tz (Tn) Mt (Tnm) My (Tnm) Mz (Tnm)
2/1 0.2723 10.47 0.000 -0.0709 0.0000 -0.1215 0.0000 -0.0674 0.0000
3/2 0.7854 30.21 0.000 -0.1135 0.0000 -0.2291 0.0000 -0.2795 0.0000
4/3 1.3399 51.53 0.000 -0.1580 0.0000 -0.3496 0.0000 -0.6426 0.0000
5/4 1.8132 69.74 0.000 -0.1744 0.0000 -0.4544 0.0000 -1.1269 0.0000
6/5 2.2328 85.88 0.000 -0.1928 0.0000 -0.5703 0.0000 -1.7441 0.0000
7/6 2.6132 100.51 0.000 -0.2135 0.0000 -0.6936 0.0000 -2.5053 0.0000
8/7 2.9624 113.94 0.000 -0.2366 0.0000 -0.8244 0.0000 -3.4197 0.0000
9/8 3.2873 126.44 0.000 -0.2619 0.0000 -0.9645 0.0000 -4.4971 0.0000
10/9 3.5882 138.01 0.000 -0.2907 0.0000 -1.0994 0.0000 -5.7402 0.0000
11/10 3.8618 148.53 0.000 -0.3229 0.0000 -1.2292 0.0000 -7.1427 0.0000
Pgina 6
MODEL: FUL-12
Wind pressure as per UNE -EN 40-3-1
Input data
Benchmark wind speed 200 Km/h (124,27 miles/h) Forecast for return period of 25 years Cs = 0,959166305
Height in metres 12 Benchmark dynamic pressure daN/m2 177,4691358 398,8261537 lbf/m2
No. of sections 10 Air density 1,25 kg/m3
Type of column section circular
Coeff. column size 0,88 Max. distortion predicted at tip 1,01 metres
Coeff. dynamic behaviour 1,74 For a forecast vibration period of 2,009975124 seconds
Coeff. topography 1
Coeff. exposure 2,89 For location of light in Terrain Cat. 1
Wind
Ext. diam. mm Exposure pressure Re*10^5 Shape Force daN/m Force Tn/m Force lbf/m
coeff. (daN/m2) coeff.
240 1,88 510,872593 12,11 0,6 73,566 0,07499 165,3240
224,80 1,88 510,872593 11,34 0,6 68,906 0,07024 154,8535
209,60 2,09 567,938148 11,15 0,6 71,424 0,07281 160,5108
194,40 2,35 638,590741 10,96 0,6 74,485 0,07593 167,3905
179,20 2,37 644,025556 10,15 0,6 69,246 0,07059 155,6156
164,00 2,48 673,917037 9,50 0,59 65,208 0,06647 146,5423
148,80 2,64 717,395556 8,90 0,58 61,914 0,06311 139,1395
133,60 2,71 736,417407 8,09 0,57 56,080 0,05717 126,0277
118,40 2,78 755,439259 7,26 0,56 50,089 0,05106 112,5641
103,20 2,83 769,026296 6,39 0,54 42,856 0,04369 96,3109
88 2,89 785,330741 5,50 0,53 36,628 0,03734 82,3137
CROSS-SECTION 1: FIXATION POINT OF COLUMN OR POLE
Verifications
Mx/Mux 1,37594386
My/Muy 0
Tp/Tu 0
Total 1,37594386 1 The cross-section does not conform
GALVANIZED STEEL AP-11
Verifications
Mx/Mux 1,12000677
My/Muy 0
Tp/Tu 0
Total 1,12000677 1 The cross-section does not conform
Verifications
Mx/Mux 0,76133541
My/Muy 0
Tp/Tu 0
Total 0,76133541 1 The cross-section conforms
The column does not conform in any of the critical sections; the sections that do not conform need to be reinforced
MODEL: FUL 12
3
Zp 207936 mm
Mux=Muy=Mup 44533,70538 Nm
1000805,371 lbfcm
Verifications
0,96347585
1 0,93699485 Mx/(MuxW/OUT REINFORCEMENT + Mux REINFORCEMENT) 0,707540203
My/(MuySW/OUT REINFORCEMENT + Muy REINFORCEMENT) 0
Tp/Tu 0
Suma 0,707540203 1
CROSS-SECTION 2: UPPER EDGE OF DOOR APERTURE 1 (WITH REINFORCEMENT TYPE 3 + REINFORCEMENT TYPE 5)
Verifications
NDICE
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 1
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:10/05/06
I ANGLES\CLCULS\FUL 12\f12cort NOU 200.EM3
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
1.1.- DESCRIPCIN
1.2.- MEDICIN
2.1.- DESCRIPCIN
2.2.- MEDICIN
Pgina 2
Listado de cimentacin
Nombre Obra: Z:\EXPEDIENTES\PROYECTOS\INGENIERIA\87-06 ESCOFET. CLCUL FULS 200KM_H Fecha:10/05/06
I ANGLES\CLCULS\FUL 12\f12cort NOU 200.EM3
FUL12 acer CORTEN 200Km/h e=5mm lumin gran
Pgina 3
JOAN MULET, S.L.
14. ANEXO:
34
JOAN MULET, S.L.
15. PLANOS:
27