Engineering Standards For Marine Oil Terminal Design and Maintenance (Motems)
Engineering Standards For Marine Oil Terminal Design and Maintenance (Motems)
September 2002
The Standards
Arm down
Tupras MOT
h o se
en
B rok
Photo by G. Johnson/EQE
Background
What Can Happen?
Ulashi Harbor: Accumulation of oil from the Tupras Refinery
Schedule
Engineering Standards Completed May 2002
Regulations to Follow (mid 2003)
MOTEMS
Scope of the Standards
Audit and Inspection Criteria
Structural Loading Criteria
Seismic Analysis and Design Criteria
Mooring and Berthing Analysis and Design
Criteria
Geotechnical Hazards Criteria
Structural Analysis and Design of Components
Piping and Pipeline Criteria
Electrical and Mechanical Equipment Criteria
The Team
U.S. Naval Facilities Engineering Service
Center
Cooperative Research & Development Agreement
Seismic, Mooring and Structural Inspection Input
Structural Criteria
CONSTRUCTION MATERIAL
Unwrapped Timber or Concrete, Wrapped Timber, Channel Bottom or Mudline Scour4
Condition Rating Unprotected Steel (no coating Protected Steel or Composite
From Previous or cathodic protection)4 Materials (FRP, plastic, etc.)4
Inspection Benign2 Aggressive3 Benign2 Aggressive3 Benign2 Aggressive3
Environment Environment Environment Environment Environment Environment
6 6 4 6 5 6 5
(Good)
5 6 4 6 5 6 5
(Satisfactory)
4 5 3 5 4 6 5
(Fair)
3 4 3 5 4 6 3
(Poor)
2 2 1 2 1 2 1
(Serious)
1 .5 .5 .5 .5 .5 .5
(Critical)
1. The recommended maximum interval between Underwater Audit Inspections should be reduced as appropriate based on the extent of deterioration observed
on a structure, the rate of further anticipated deterioration, or other factors.
2. Benign environments include fresh water with low to moderate currents (maximum current always < .75 kts)
3. Aggressive environments include brackish or salt water, polluted water, or waters with moderate to swift currents (maximum current .75 kts)
4. For most structures, two maximum intervals will be shown in this table, one for the assessment of construction material (timber, concrete, steel, etc) and one
for scour (last 2 columns). The shorter interval of the two should dictate the maximum interval used.
The Standards
Structural Criteria
Dead Loads
Live Loads
Seismic Loads
Risk Classification:
TABLE 2
EXISTING FACILITY CLASSIFICATION
Classification Exposed Oil (bbl) Transfers per Vessel Size (DWTx1000)
Level Year/Facility
High 1200 N.A. N.A.
Moderate < 1200 90 30
Low < 1200 < 90 < 30
The Standards
Structural Criteria: Seismic
Performance Criteria:
Level 1 Earthquake: No or minor structural damage
without interruption in service or with minor
temporary interruption in service.
TABLE 5
FACILITY RISK CLASSIFICATION
Risk Level Wind, (Vw) Current, (Vc) Passing Vessels Tidal Variation
High > 50 knots > 1.5 knots Yes > 8 feet
Moderate 30 to 50 0.75 to 1.5 knots No 6 to 8
Low < 30 knots < 0.75 knot No < 6 feet