Professional Documents
Culture Documents
Li Ion Batteries PDF
Li Ion Batteries PDF
Cells
Circuit board
protection circuitry
fuel gauge
communications bus
Insulation
External contacts
Vent holes
Plastic enclosure
Safety Circuits for Lithium-Ion Batteries
Large Scale Battery Management:
Challenges for high capacity
Vendor Support
Balancing
High current circuit design
Diodes- odd number of cells
Fuel gauge limitations
Shipping regulations
Solutions:
Bigger cells
Modules
Heat sinks
Active cooling
Large ICs
Large Scale Battery Management:
Challenges for high voltage
Shipping
Thermal management For a given wattage
Cell matching high series is more
Pack reliability effective than high
parallel cell count
Fuel gauging
Cycle life
Cell balancing
Temperature Becomes a
Greater Factor:
Gradients Are Larger
Physical Cell Arrangement Can
Influence Temperature
High Rate Charge/Discharge
Cext
Cext + Rextbal
+
Battery
Cell
Ibias
Ibalance
IC VCn+1 pin
IC VCn+1 pin
Rext Rext
- Vgate +
Limit to internal FET capacity External MOSFET can be controlled by the state of the
10 - 200 mA per datasheet integrated FET
Real value based on thermals Higher bypassing current is achieved due to low Rdson of
the external FETs
Gate voltage is limited by resistance across the lower
Rext (Rvcx)
10 Series System 50mA
VC1
CB1
VC2
CB2
VC3
Cell Measurement /
Interface Circuits
VC9
CB9
VC10
CB10
VC11
10 Series System 200mA
VC1
CB1
VC2
CB2
VC3
Cell Measurement /
Interface Circuits
VC9
CB9
VC10
CB10
VC11
Bypass Balance Review
Ends of OCV curve makes largest difference
Recommended to balance during charge cycle
Duty cycle limitations
Amount of energy moved is limited to by time,
temperature and current
Cost of high current resistors & low ohm FETs
Energy conservation vs energy stored/delivered
Thermally challenging at high temp portions of pack life
Charge Redistribution Cell Balancing
Basics
Energy transfer between adjacent cells
Move energy where and when its needed to minimize
global imbalance
Current path is outside of charge / discharge path
Can be implemented during charge, idle and discharge
periods
Topology Choices
Capacitive switch capacitor across higher cell to lower
cell
Inductive store energy from higher cell before delivering
it to lower cell
Capacitive Redistribution
Imbalance example:
Cell 2 is a lower voltage or
capacitance
Move energy from Cell 1 and
Cell 2
PowerPumpTM Operation
Control Signals
from IC
Control Signals
from IC
Voltage Balanced...
3.8
3.6
3.4
3.2
Cell Voltage
2.8
2.6
Equal Cell Voltages here
2.4
Leaves cells with SOC imbalance
2.2 Allowing cells to drop below cutoff
2
0.00 10.00 20.00 30.00 40.00
Time Minutes
Challenges with New Chemistries
Predictive Balancing Maintains EOD Balance
3.8
3.6
3.4
3.2
Cell Voltage
2.8
76PL102 15H
(Charge, Idle, Discharge) 3300pF
1.0
PowerLAN SDI 2K
+
Balance Current .001 PUMP2N
1.0
Sized Externally SDO 3300pF
20K
Inductor and V1 V2-n
Dual FETs V1+n
20K
PUMP2S +
Typical 15H
Example 2-cell circuit Temperature 3300pF
Sensor
shown. ICs available for MMBD4148SE 1.0
up to 6 series cells. XTMPx 2K
.001 PUMP1N
VPP 1.0
3300pF
VLDO PUMP1S 20K
VSS
V1-n
TAB
1.0